History log of /openbmc/linux/Documentation/ABI/testing/sysfs-bus-cxl (Results 26 – 32 of 32)
Revision (<<< Hide revision tags) (Show revision tags >>>) Date Author Comments
# cf1f6877 23-Jan-2022 Dan Williams <dan.j.williams@intel.com>

cxl/memdev: Add numa_node attribute

While CXL memory targets will have their own memory target node,
individual memory devices may be affinitized like other PCI devices.
Emit that attribute for memd

cxl/memdev: Add numa_node attribute

While CXL memory targets will have their own memory target node,
individual memory devices may be affinitized like other PCI devices.
Emit that attribute for memdevs.

Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Link: https://lore.kernel.org/r/164298428430.3018233.16409089892707993289.stgit@dwillia2-desk3.amr.corp.intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...


# bcc79ea3 31-Jan-2022 Dan Williams <dan.j.williams@intel.com>

cxl/pci: Emit device serial number

Per the CXL specification (8.1.12.2 Memory Device PCIe Capabilities and
Extended Capabilities) the Device Serial Number capability is mandatory.
Emit it for user t

cxl/pci: Emit device serial number

Per the CXL specification (8.1.12.2 Memory Device PCIe Capabilities and
Extended Capabilities) the Device Serial Number capability is mandatory.
Emit it for user tooling to identify devices.

It is reasonable to ask whether the attribute should be added to the
list of PCI sysfs device attributes. The PCI layer can optionally emit
it too, but the CXL subsystem is aiming to preserve its independence and
the possibility of CXL topologies with non-PCI devices in it. To date
that has only proven useful for the 'cxl_test' model, but as can be seen
with seen with ACPI0016 devices, sometimes all that is needed is a
platform firmware table to point to CXL Component Registers in MMIO
space to define a "CXL" device.

Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Link: https://lore.kernel.org/r/164366608838.196598.16856227191534267098.stgit@dwillia2-desk3.amr.corp.intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...


# 83fbdbe4 23-Jan-2022 Dan Williams <dan.j.williams@intel.com>

cxl/core: Emit modalias for CXL devices

In order to enable libkmod lookups for CXL device objects to their
corresponding module, add 'modalias' to the base attribute of CXL
devices.

Reviewed-by: Jo

cxl/core: Emit modalias for CXL devices

In order to enable libkmod lookups for CXL device objects to their
corresponding module, add 'modalias' to the base attribute of CXL
devices.

Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Reviewed-by: Ben Widawsky <ben.widawsky@intel.com>
Link: https://lore.kernel.org/r/164298424120.3018233.15611905873808708542.stgit@dwillia2-desk3.amr.corp.intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...


# 40ba17af 09-Jun-2021 Dan Williams <dan.j.williams@intel.com>

cxl/acpi: Introduce cxl_decoder objects

A cxl_decoder is a child of a cxl_port. It represents a hardware decoder
configuration of an upstream port to one or more of its downstream
ports. The decoder

cxl/acpi: Introduce cxl_decoder objects

A cxl_decoder is a child of a cxl_port. It represents a hardware decoder
configuration of an upstream port to one or more of its downstream
ports. The decoder is either represented in CXL standard HDM decoder
registers (see CXL 2.0 section 8.2.5.12 CXL HDM Decoder Capability
Structure), or it is a static decode configuration communicated by
platform firmware (see the CXL Early Discovery Table: Fixed Memory
Window Structure).

The firmware described and hardware described decoders differ slightly
leading to 2 different sub-types of decoders, cxl_decoder_root and
cxl_decoder_switch. At the root level the decode capabilities restrict
what can be mapped beneath them. Mid-level switch decoders are
configured for either acclerator (type-2) or memory-expander (type-3)
operation, but they are otherwise agnostic to the type of memory
(volatile vs persistent) being mapped.

Here is an example topology from a single-ported host-bridge environment
without CFMWS decodes enumerated.

/sys/bus/cxl/devices/root0
├── devtype
├── dport0 -> ../../../LNXSYSTM:00/LNXSYBUS:00/ACPI0016:00
├── port1
│   ├── decoder1.0
│   │   ├── devtype
│   │   ├── locked
│   │   ├── size
│   │   ├── start
│   │   ├── subsystem -> ../../../../../../bus/cxl
│   │   ├── target_list
│   │   ├── target_type
│   │   └── uevent
│   ├── devtype
│   ├── dport0 -> ../../../../pci0000:34/0000:34:00.0
│   ├── subsystem -> ../../../../../bus/cxl
│   ├── uevent
│   └── uport -> ../../../../LNXSYSTM:00/LNXSYBUS:00/ACPI0016:00
├── subsystem -> ../../../../bus/cxl
├── uevent
└── uport -> ../../ACPI0017:00

Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Link: https://lore.kernel.org/r/162325695128.2293823.17519927266014762694.stgit@dwillia2-desk3.amr.corp.intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...


# 7d4b5ca2 09-Jun-2021 Dan Williams <dan.j.williams@intel.com>

cxl/acpi: Add downstream port data to cxl_port instances

In preparation for infrastructure that enumerates and configures the CXL
decode mechanism of an upstream port to its downstream ports, add a

cxl/acpi: Add downstream port data to cxl_port instances

In preparation for infrastructure that enumerates and configures the CXL
decode mechanism of an upstream port to its downstream ports, add a
representation of a CXL downstream port.

On ACPI systems the top-most logical downstream ports in the hierarchy
are the host bridges (ACPI0016 devices) that decode the memory windows
described by the CXL Early Discovery Table Fixed Memory Window
Structures (CEDT.CFMWS).

Reviewed-by: Alison Schofield <alison.schofield@intel.com>
Link: https://lore.kernel.org/r/162325450624.2293126.3533006409920271718.stgit@dwillia2-desk3.amr.corp.intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...


# 4812be97 09-Jun-2021 Dan Williams <dan.j.williams@intel.com>

cxl/acpi: Introduce the root of a cxl_port topology

While CXL builds upon the PCI software model for enumeration and
endpoint control, a static platform component is required to bootstrap
the CXL me

cxl/acpi: Introduce the root of a cxl_port topology

While CXL builds upon the PCI software model for enumeration and
endpoint control, a static platform component is required to bootstrap
the CXL memory layout. Similar to how ACPI identifies root-level PCI
memory resources, ACPI data enumerates the address space and interleave
configuration for CXL Memory.

In addition to identifying host bridges, ACPI is responsible for
enumerating the CXL memory space that can be addressed by downstream
decoders. This is similar to the requirement for ACPI to publish
resources via the _CRS method for PCI host bridges. Specifically, ACPI
publishes a table, CXL Early Discovery Table (CEDT), which includes a
list of CXL Memory resources, CXL Fixed Memory Window Structures
(CFMWS).

For now, introduce the core infrastructure for a cxl_port hierarchy
starting with a root level anchor represented by the ACPI0017 device.

Follow on changes model support for the configurable decode capabilities
of cxl_port instances, i.e. CXL switch support.

Co-developed-by: Alison Schofield <alison.schofield@intel.com>
Signed-off-by: Alison Schofield <alison.schofield@intel.com>
Acked-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Link: https://lore.kernel.org/r/162325449515.2293126.15303270193010154608.stgit@dwillia2-desk3.amr.corp.intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...


Revision tags: v5.10.40, v5.10.39, v5.4.119, v5.10.36, v5.10.35, v5.10.34, v5.4.116, v5.10.33, v5.12, v5.10.32, v5.10.31, v5.10.30, v5.10.27, v5.10.26, v5.10.25, v5.10.24, v5.10.23, v5.10.22, v5.10.21, v5.10.20, v5.10.19, v5.4.101, v5.10.18, v5.10.17
# b39cb105 16-Feb-2021 Dan Williams <dan.j.williams@intel.com>

cxl/mem: Register CXL memX devices

Create the /sys/bus/cxl hierarchy to enumerate:

* Memory Devices (per-endpoint control devices)

* Memory Address Space Devices (platform address ranges with
in

cxl/mem: Register CXL memX devices

Create the /sys/bus/cxl hierarchy to enumerate:

* Memory Devices (per-endpoint control devices)

* Memory Address Space Devices (platform address ranges with
interleaving, performance, and persistence attributes)

* Memory Regions (active provisioned memory from an address space device
that is in use as System RAM or delegated to libnvdimm as Persistent
Memory regions).

For now, only the per-endpoint control devices are registered on the
'cxl' bus. However, going forward it will provide a mechanism to
coordinate cross-device interleave.

Signed-off-by: Ben Widawsky <ben.widawsky@intel.com>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> (v2)
Link: https://lore.kernel.org/r/20210217040958.1354670-4-ben.widawsky@intel.com
Signed-off-by: Dan Williams <dan.j.williams@intel.com>

show more ...