1# OpenPower Platform Event Log (PEL) extension
2
3This extension will create PELs for every OpenBMC event log. It is also possible
4to point to the raw PEL to use in the OpenBMC event, and then that will be used
5instead of creating one.
6
7## Contents
8
9- [Passing in data when creating PELs](#passing-pel-related-data-within-an-openbmc-event-log)
10- [Default UserData sections for BMC created PELs](#default-userdata-sections-for-bmc-created-pels)
11- [The PEL Message Registry](#the-pel-message-registry)
12- [Callouts](#callouts)
13- [Action Flags and Event Type Rules](#action-flags-and-event-type-rules)
14- [D-Bus Interfaces](#d-bus-interfaces)
15- [PEL Retention](#pel-retention)
16- [Adding python3 modules for PEL UserData and SRC parsing](#adding-python3-modules-for-pel-userdata-and-src-parsing)
17- [Fail Boot on Host Errors](#fail-boot-on-host-errors)
18- [SBE FFDC](#self-boot-engine-first-failure-data-capture-support)
19- [PEL Archiving](#pel-archiving)
20- [Handling PELs for hot plugged FRUs](#handling-pels-for-hot-plugged-frus)
21
22## Passing PEL related data within an OpenBMC event log
23
24An error log creator can pass in data that is relevant to a PEL by using certain
25keywords in the AdditionalData property of the event log.
26
27### AdditionalData keywords
28
29#### RAWPEL
30
31This keyword is used to point to an existing PEL in a binary file that should be
32associated with this event log. The syntax is:
33
34```ascii
35RAWPEL=<path to PEL File>
36e.g.
37RAWPEL="/tmp/pels/pel.5"
38```
39
40The code will assign its own error log ID to this PEL, and also update the
41commit timestamp field to the current time.
42
43#### POWER_THERMAL_CRITICAL_FAULT
44
45This keyword is used to set the power fault bit in PEL. The syntax is:
46
47```ascii
48POWER_THERMAL_CRITICAL_FAULT=<FLAG>
49e.g.
50POWER_THERMAL_CRITICAL_FAULT=TRUE
51```
52
53Note that TRUE is the only value supported.
54
55#### SEVERITY_DETAIL
56
57This is used when the passed in event log severity determines the PEL severity
58and a more granular PEL severity is needed beyond what the normal event log to
59PEL severity conversion could give.
60
61The syntax is:
62
63```ascii
64SEVERITY_DETAIL=<SEVERITY_TYPE>
65e.g.
66SEVERITY_DETAIL=SYSTEM_TERM
67```
68
69Option Supported:
70
71- SYSTEM_TERM, changes the Severity value from 0x50 to 0x51
72
73#### ESEL
74
75This keyword's data contains a full PEL in string format. This is how hostboot
76sends down PELs when it is configured in IPMI communication mode. The PEL is
77handled just like the PEL obtained using the RAWPEL keyword.
78
79The syntax is:
80
81```ascii
82ESEL=
83"00 00 df 00 00 00 00 20 00 04 12 01 6f aa 00 00 50 48 00 30 01 00 33 00 00..."
84```
85
86Note that there are 16 bytes of IPMI SEL data before the PEL data starts.
87
88#### \_PID
89
90This keyword that contains the application's PID is added automatically by the
91phosphor-logging daemon when the `commit` or `report` APIs are used to create an
92event log, but not when the `Create` D-Bus method is used. If a caller of the
93`Create` API wishes to have their PID captured in the PEL this should be used.
94
95This will be added to the PEL in a section of type User Data (UD), along with
96the application name it corresponds to.
97
98The syntax is:
99
100```ascii
101_PID=<PID of application>
102e.g.
103_PID="12345"
104```
105
106#### CALLOUT_INVENTORY_PATH
107
108This is used to pass in an inventory item to use as a callout. See
109[here for details](#passing-callouts-in-with-the-additionaldata-property)
110
111#### CALLOUT_PRIORITY
112
113This can be used along with CALLOUT_INVENTORY_PATH to specify the priority of
114that FRU callout. If not specified, the default priority is "H"/High Priority.
115
116The possible values are:
117
118- "H": High Priority
119- "M": Medium Priority
120- "L": Low Priority
121
122See [here for details](#passing-callouts-in-with-the-additionaldata-property)
123
124#### CALLOUT_DEVICE_PATH with CALLOUT_ERRNO
125
126This is used to pass in a device path to create callouts from. See
127[here for details](#passing-callouts-in-with-the-additionaldata-property)
128
129#### CALLOUT_IIC_BUS with CALLOUT_IIC_ADDR and CALLOUT_ERRNO
130
131This is used to pass in an I2C bus and address to create callouts from. See
132[here for details](#passing-callouts-in-with-the-additionaldata-property)
133
134#### PEL_SUBSYSTEM
135
136This keyword is used to pass in the subsystem that should be associated with
137this event log. The syntax is: `PEL_SUBSYSTEM=<subsystem value in hex>` e.g.
138PEL_SUBSYSTEM=0x20
139
140### FFDC Intended For UserData PEL sections
141
142When one needs to add FFDC into the PEL UserData sections, the
143`CreateWithFFDCFiles` D-Bus method on the `xyz.openbmc_project.Logging.Create`
144interface must be used when creating a new event log. This method takes a list
145of files to store in the PEL UserData sections.
146
147That API is the same as the 'Create' one, except it has a new parameter:
148
149```cpp
150std::vector<std::tuple<enum[FFDCFormat],
151 uint8_t,
152 uint8_t,
153 sdbusplus::message::unix_fd>>
154```
155
156Each entry in the vector contains a file descriptor for a file that will be
157stored in a unique UserData section. The tuple's arguments are:
158
159- enum[FFDCFormat]: The data format type, the options are:
160 - 'JSON'
161 - The parser will use nlohmann::json\'s pretty print
162 - 'CBOR'
163 - The parser will use nlohmann::json\'s pretty print
164 - 'Text'
165 - The parser will output ASCII text
166 - 'Custom'
167 - The parser will hexdump the data, unless there is a parser registered for
168 this component ID and subtype.
169- uint8_t: subType
170 - Useful for the 'custom' type. Not used with the other types.
171- uint8_t: version
172 - The version of the data.
173 - Used for the custom type.
174 - Not planning on using for JSON/BSON unless a reason to do so appears.
175- unixfd - The file descriptor for the opened file that contains the contents.
176 The file descriptor can be closed and the file can be deleted if desired after
177 the method call.
178
179An example of saving JSON data to a file and getting its file descriptor is:
180
181```cpp
182nlohmann::json json = ...;
183auto jsonString = json.dump();
184FILE* fp = fopen(filename, "w");
185fwrite(jsonString.data(), 1, jsonString.size(), fp);
186int fd = fileno(fp);
187```
188
189Alternatively, 'open()' can be used to obtain the file descriptor of the file.
190
191Upon receiving this data, the PEL code will create UserData sections for each
192entry in that vector with the following UserData fields:
193
194- Section header component ID:
195 - If the type field from the tuple is "custom", use the component ID from the
196 message registry.
197 - Otherwise, set the component ID to the phosphor-logging component ID so that
198 the parser knows to use the built in parsers (e.g. json) for the type.
199- Section header subtype: The subtype field from the tuple.
200- Section header version: The version field from the tuple.
201- Section data: The data from the file.
202
203If there is a peltool parser registered for the custom type (method is TBD),
204that will be used by peltool to print the data, otherwise it will be hexdumped.
205
206Before adding each of these UserData sections, a check will be done to see if
207the PEL size will remain under the maximum size of 16KB. If not, the UserData
208section will be truncated down enough so that it will fit into the 16KB.
209
210## Default UserData sections for BMC created PELs
211
212The extension code that creates PELs will add these UserData sections to every
213PEL:
214
215- The AdditionalData property contents
216 - If the AdditionalData property in the OpenBMC event log has anything in it,
217 it will be saved in a UserData section as a JSON string.
218
219- System information
220 - This section contains various pieces of system information, such as the full
221 code level and the BMC, chassis, and host state properties.
222
223## The PEL Message Registry
224
225The PEL message registry is used to create PELs from OpenBMC event logs.
226[Documentation](registry/README.md) is available.
227
228## Callouts
229
230A callout points to a FRU, a symbolic FRU, or an isolation procedure. There can
231be from zero to ten of them in each PEL, where they are located in the SRC
232section.
233
234There are a few different ways to add callouts to a PEL. In all cases, the
235callouts will be sorted from highest to lowest priority within the PEL after
236they are added.
237
238### Passing callouts in with the AdditionalData property
239
240The PEL code can add callouts based on the values of special entries in the
241AdditionalData event log property. They are:
242
243- CALLOUT_INVENTORY_PATH
244
245 This keyword is used to call out a single FRU by passing in its D-Bus
246 inventory path. When the PEL code sees this, it will create a single FRU
247 callout, using the VPD properties (location code, FN, CCIN) from that
248 inventory item. If that item is not a FRU itself and does not have a location
249 code, it will keep searching its parents until it finds one that is.
250
251 The priority of the FRU callout will be high, unless the CALLOUT_PRIORITY
252 keyword is also present and contains a different priority in which case it
253 will be used instead. This can be useful when a maintenance procedure with a
254 high priority callout is specified for this error in the message registry and
255 the FRU callout needs to have a different priority.
256
257```ascii
258 CALLOUT_INVENTORY_PATH=
259 "/xyz/openbmc_project/inventory/system/chassis/motherboard"
260```
261
262- CALLOUT_DEVICE_PATH with CALLOUT_ERRNO
263
264 These keywords are required as a pair to indicate faulty device communication,
265 usually detected by a failure accessing a device at that sysfs path. The PEL
266 code will use a data table generated by the MRW to map these device paths to
267 FRU callout lists. The errno value may influence the callout.
268
269 I2C, FSI, FSI-I2C, and FSI-SPI paths are supported.
270
271```ascii
272 CALLOUT_DEVICE_PATH="/sys/bus/i2c/devices/3-0069"
273 CALLOUT_ERRNO="2"
274```
275
276- CALLOUT_IIC_BUS with CALLOUT_IIC_ADDR and CALLOUT_ERRNO
277
278 These 3 keywords can be used to callout a failing I2C device path when the
279 full device path isn't known. It is similar to CALLOUT_DEVICE_PATH in that it
280 will use data tables generated by the MRW to create the callouts.
281
282 CALLOUT_IIC_BUS is in the form "/dev/i2c-X" where X is the bus number, or just
283 the bus number by itself. CALLOUT_IIC_ADDR is the 7 bit address either as a
284 decimal or a hex number if preceded with a "0x".
285
286```ascii
287 CALLOUT_IIC_BUS="/dev/i2c-7"
288 CALLOUT_IIC_ADDR="81"
289 CALLOUT_ERRNO=62
290```
291
292### Defining callouts in the message registry
293
294Callouts can be completely defined inside that error's definition in the PEL
295message registry. This method allows the callouts to vary based on the system
296type or on any AdditionalData item.
297
298At a high level, this involves defining a callout section inside the registry
299entry that contain the location codes or procedure names to use, along with
300their priority. If these can vary based on system type, the type provided by the
301entity manager will be one of the keys. If they can also depend on an
302AdditionalData entry, then that will also be a key.
303
304See the message registry [README](registry/README.md) and
305[schema](registry/schema/schema.json) for the details.
306
307### Using the message registry along with CALLOUT\_ entries
308
309If the message registry entry contains a callout definition and the event log
310also contains one of aforementioned CALLOUT keys in the AdditionalData property,
311then the PEL code will first add the callouts stemming from the CALLOUT items,
312followed by the callouts from the message registry.
313
314### Specifying multiple callouts using JSON format FFDC files
315
316Multiple callouts can be passed in by the creator at the time of PEL creation.
317This is done by specifying them in a JSON file that is then passed in as an
318[FFDC file](#ffdc-intended-for-userdata-pel-sections). The JSON will still be
319added into a PEL UserData section for debug.
320
321To specify that an FFDC file contains callouts, the format value for that FFDC
322entry must be set to JSON, and the subtype field must be set to 0xCA:
323
324```cpp
325using FFDC = std::tuple<CreateIface::FFDCFormat,
326 uint8_t,
327 uint8_t,
328 sdbusplus::message::unix_fd>;
329
330FFDC ffdc{
331 CreateIface::FFDCFormat::JSON,
332 0xCA, // Callout subtype
333 0x01, // Callout version, set to 0x01
334 fd};
335```
336
337The JSON contains an array of callouts that must be in order of highest priority
338to lowest, with a maximum of 10. Any callouts after the 10th will just be thrown
339away as there is no room for them in the PEL. The format looks like:
340
341```jsonl
342[
343 {
344 // First callout
345 },
346 {
347 // Second callout
348 },
349 {
350 // Nth callout
351 }
352]
353```
354
355A callout entry can be a normal hardware callout, a maintenance procedure
356callout, or a symbolic FRU callout. Each callout must contain a Priority field,
357where the possible values are:
358
359- "H" = High
360- "M" = Medium
361- "A" = Medium Group A
362- "B" = Medium Group B
363- "C" = Medium Group C
364- "L" = Low
365
366Either unexpanded location codes or D-Bus inventory object paths can be used to
367specify the called out part. An unexpanded location code does not have the
368system VPD information embedded in it, and the 'Ufcs-' prefix is optional (so
369can be either Ufcs-P1 or just P1).
370
371#### Normal hardware FRU callout
372
373Normal hardware callouts must contain either the location code or inventory
374path, and priority. Even though the PEL code doesn't do any guarding or
375deconfiguring itself, it needs to know if either of those things occurred as
376there are status bits in the PEL to reflect them. The Guarded and Deconfigured
377fields are used for this. Those fields are optional and if omitted then their
378values will be false.
379
380When the inventory path of a sub-FRU is passed in, the PEL code will put the
381location code of the parent FRU into the callout.
382
383```jsonl
384{
385 "LocationCode": "P0-C1",
386 "Priority": "H"
387}
388
389{
390 "InventoryPath": "/xyz/openbmc_project/inventory/motherboard/cpu0/core5",
391 "Priority": "H",
392 "Deconfigured": true,
393 "Guarded": true
394}
395
396```
397
398MRUs (Manufacturing Replaceable Units) are 4 byte numbers that can optionally be
399added to callouts to specify failing devices on a FRU. These may be used during
400the manufacturing test process, where there may be the ability to do these
401replacements. There can be up to 15 MRUs, each with its own priority, embedded
402in a callout. The possible priority values match the FRU priority values.
403
404Note that since JSON only supports numbers in decimal and not in hex, MRU IDs
405will show up as decimal when visually inspecting the JSON.
406
407```jsonl
408{
409 "LocationCode": "P0-C1",
410 "Priority": "H",
411 "MRUs": [
412 {
413 "ID": 1234,
414 "Priority": "H"
415 },
416 {
417 "ID": 5678,
418 "Priority": "H"
419 }
420 ]
421}
422```
423
424#### Maintenance procedure callout
425
426The LocationCode field is not used with procedure callouts. Only the first 7
427characters of the Procedure field will be used by the PEL.
428
429```jsonl
430{
431 "Procedure": "PRONAME",
432 "Priority": "H"
433}
434```
435
436#### Symbolic FRU callout
437
438Only the first seven characters of the SymbolicFRU field will be used by the
439PEL.
440
441If the TrustedLocationCode field is present and set to true, this means the
442location code may be used to turn on service indicators, so the LocationCode
443field is required. If TrustedLocationCode is false or missing, then the
444LocationCode field is optional.
445
446```jsonl
447{
448 "TrustedLocationCode": true,
449 "Location Code": "P0-C1",
450 "Priority": "H",
451 "SymbolicFRU": "FRUNAME"
452}
453```
454
455## `Action Flags` and `Event Type` Rules
456
457The `Action Flags` and `Event Type` PEL fields are optional in the message
458registry, and if not present the code will set them based on certain rules layed
459out in the PEL spec.
460
461These rules are:
462
4631. Always set the `Report` flag, unless the `Do Not Report` flag is already on.
4642. Always clear the `SP Call Home` flag, as that feature isn't supported.
4653. If the severity is `Non-error Event`:
466 - Clear the `Service Action` flag.
467 - Clear the `Call Home` flag.
468 - If the `Event Type` field is `Not Applicable`, change it to
469 `Information Only`.
470 - If the `Event Type` field is `Information Only` or `Tracing`, set the
471 `Hidden` flag.
4724. If the severity is `Recovered`:
473 - Set the `Hidden` flag.
474 - Clear the `Service Action` flag.
475 - Clear the `Call Home` flag.
4765. For all other severities:
477 - Clear the `Hidden` flag.
478 - Set the `Service Action` flag.
479 - Set the `Call Home` flag.
480
481Additional rules may be added in the future if necessary.
482
483## D-Bus Interfaces
484
485See the org.open_power.Logging.PEL interface definition for the most up to date
486information.
487
488## PEL Retention
489
490The PEL repository is allocated a set amount of space on the BMC. When that
491space gets close to being full, the code will remove a percentage of PELs to
492make room for new ones. In addition, the code will keep a cap on the total
493number of PELs allowed. Note that removing a PEL will also remove the
494corresponding OpenBMC event log.
495
496The disk capacity limit is set to 20MB, and the number limit is 3000.
497
498The rules used to remove logs are listed below. The checks will be run after a
499PEL has been added and the method to create the PEL has returned to the caller,
500i.e. run when control gets back to the event loop.
501
502### Removal Algorithm
503
504If the size used is 95% or under of the allocated space and under the limit on
505the number of PELs, nothing further needs to be done, otherwise continue and run
506all 5 of the following steps. Each step itself only deletes PELs until it meets
507its requirement and then it stops.
508
509The steps are:
510
5111. Remove BMC created informational PELs until they take up 15% or less of the
512 allocated space.
513
5142. Remove BMC created non-informational PELs until they take up 30% or less of
515 the allocated space.
516
5173. Remove non-BMC created informational PELs until they take up 15% or less of
518 the allocated space.
519
5204. Remove non-BMC created non-informational PELs until they take up 30% or less
521 of the allocated space.
522
5235. After the previous 4 steps are complete, if there are still more than the
524 maximum number of PELs, remove PELs down to 80% of the maximum.
525
526PELs with associated guard records will never be deleted. Each step above makes
527the following 4 passes, stopping as soon as its limit is reached:
528
529- Pass 1. Remove HMC acknowledged PELs.
530- Pass 2. Remove OS acknowledged PELs.
531- Pass 3. Remove PHYP acknowledged PELs.
532- Pass 4. Remove all PELs.
533
534After all these steps, disk capacity will be at most 90% (15% + 30% + 15% +
53530%).
536
537## Adding python3 modules for PEL UserData and SRC parsing
538
539In order to support python3 modules for the parsing of PEL User Data sections
540and to decode SRC data, setuptools is used to import python3 packages from
541external repos to be included in the OpenBMC image.
542
543Sample layout for setuptools:
544
545setup.py src/usr/scom/plugins/ebmc/b0300.py src/usr/i2c/plugins/ebmc/b0700.py
546src/build/tools/ebmc/errludP_Helpers.py
547
548`setup.py` is the build script for setuptools. It contains information about the
549package (such as the name and version) as well as which code files to include.
550
551The setup.py template to be used for eBMC User Data parsers:
552
553```python3
554import os.path
555from setuptools import setup
556
557# To update this dict with new key/value pair for every component added
558# Key: The package name to be installed as
559# Value: The path containing the package's python modules
560dirmap = {
561 "b0300": "src/usr/scom/plugins/ebmc",
562 "b0700": "src/usr/i2c/plugins/ebmc",
563 "helpers": "src/build/tools/ebmc"
564}
565
566# All packages will be installed under 'udparsers' namespace
567def get_package_name(dirmap_key):
568 return "udparsers.{}".format(dirmap_key)
569
570def get_package_dirent(dirmap_item):
571 package_name = get_package_name(dirmap_item[0])
572 package_dir = dirmap_item[1]
573 return (package_name, package_dir)
574
575def get_packages():
576 return map(get_package_name, dirmap.keys())
577
578def get_package_dirs():
579 return map(get_package_dirent, dirmap.items())
580
581setup(
582 name="Hostboot",
583 version="0.1",
584 packages=list(get_packages()),
585 package_dir=dict(get_package_dirs())
586)
587```
588
589- User Data parser module
590 - Module name: `xzzzz.py`, where `x` is the Creator Subsystem from the Private
591 Header section (in ASCII) and `zzzz` is the 2 byte Component ID from the
592 User Data section itself (in HEX). All should be converted to lowercase.
593 - For example: `b0100.py` for Hostboot created UserData with CompID 0x0100
594 - Function to provide: `parseUDToJson`
595 - Argument list:
596 1. (int) Sub-section type
597 2. (int) Section version
598 3. (memoryview): Data
599 - Return data:
600 1. (str) JSON string
601
602 - Sample User Data parser module:
603
604```python3
605 import json
606 def parseUDToJson(subType, ver, data):
607 d = dict()
608 ...
609 # Parse and populate data into dictionary
610 ...
611 jsonStr = json.dumps(d)
612 return jsonStr
613```
614
615- SRC parser module
616 - Module name: `xsrc.py`, where `x` is the Creator Subsystem from the Private
617 Header section (in ASCII, converted to lowercase).
618 - For example: `bsrc.py` for Hostboot generated SRCs
619 - Function to provide: `parseSRCToJson`
620 - Argument list:
621 1. (str) Refcode ASCII string
622 2. (str) Hexword 2
623 3. (str) Hexword 3
624 4. (str) Hexword 4
625 5. (str) Hexword 5
626 6. (str) Hexword 6
627 7. (str) Hexword 7
628 8. (str) Hexword 8
629 9. (str) Hexword 9
630 - Return data:
631 1. (str) JSON string
632
633 - Sample SRC parser module:
634
635 ```python3
636 import json
637 def parseSRCToJson(ascii_str, word2, word3, word4, word5, word6, word7, \
638 word8, word9):
639 d = dict({'A': 1, 'B': 2})
640 ...
641 # Decode SRC data into dictionary
642 ...
643 jsonStr = json.dumps(d)
644 return jsonStr
645 ```
646
647## Fail Boot on Host Errors
648
649The fail boot on hw error [design][1] provides a function where a system owner
650can tell the firmware to fail the boot of a system if a BMC phosphor-logging
651event has a hardware callout in it.
652
653It is required that when this fail boot on hardware error setting is enabled,
654that the BMC fail the boot for **any** error from the host which satisfies the
655following criteria:
656
657- not SeverityType::nonError
658- has a callout of any kind from the `FailingComponentType` structure
659
660## Self Boot Engine First Failure Data Capture Support
661
662During SBE chip-op failure SBE creates FFDC with custom data format. SBE FFDC
663contains different packets, which include SBE internal failure related Trace and
664user data also Hardware procedure failure FFDC created by FAPI infrastructure.
665PEL infrastructure provides support to process SBE FFDC packets created by FAPI
666infrastructure during hardware procedure execution failures, also add callouts,
667user data section information based on FAPI processing in case non FAPI based
668failure, just keeps the raw FFDC data in the user section to support SBE parser
669plugins.
670
671CreatePELWithFFDCFiles D-Bus method on the `org.open_power.Logging.PEL`
672interface must be used when creating a new event log.
673
674To specify that an FFDC file contains SBE FFDC, the format value for that FFDC
675entry must be set to "custom", and the subtype field must be set to 0xCB:
676
677```cpp
678using FFDC = std::tuple<CreateIface::FFDCFormat,
679 uint8_t,
680 uint8_t,
681 sdbusplus::message::unix_fd>;
682
683FFDC ffdc{
684 CreateIface::FFDCFormat::custom,
685 0xCB, // SBE FFDC subtype
686 0x01, // SBE FFDC version, set to 0x01
687 fd};
688```
689
690"SRC6" Keyword in the additional data section should be populated with below.
691
692- [0:15] chip position (hex)
693- [16:23] command class (hex)
694- [24:31] command (hex)
695
696e.g for GetSCOM
697
698SRC6="0002A201"
699
700Note: "phal" build-time configure option should be "enabled" to enable this
701feature.
702
703## PEL Archiving
704
705When an OpenBMC event log is deleted its corresponding PEL is moved to an
706archive folder. These archived PELs will be available in BMC dump. The archive
707path: /var/lib/phosphor-logging/extensions/pels/logs/archive.
708
709Highlighted points are:
710
711- PELs whose corresponding event logs have been deleted will be available in the
712 archive folder.
713- Archive folder size is tracked along with logs folder size and if combined
714 size exceeds warning size all archived PELs will be deleted.
715- Archived PEL logs can be viewed using peltool with flag --archive.
716- If a PEL is deleted using peltool its not archived.
717
718## Handling PELs for hot plugged FRUs
719
720The degraded mode reporting functionality (i.e. nag) implemented by IBM creates
721periodic degraded mode reports when a system is running in degraded mode. This
722includes when hardware has been deconfigured or guarded by hostboot, and also
723when there is a fault on a redundant fan, VRM, or power supply. The report
724includes the PELs created for the fails leading to the degraded mode. These PELs
725can be identified by the 'deconfig' or 'guard' flags set in the SRC of BMC or
726hostboot PELs.
727
728Fans and power supplies can be hot plugged when they are replaced, and as that
729FRU is no longer considered degraded the PELs that led to its replacement no
730longer need be picked up in the degraded mode report.
731
732To handle this, the PEL daemon will watch the inventory D-Bus objects that have
733the 'xyz.openbmc_project.Inventory.Item.Fan' or
734'xyz.openbmc_project.Inventory.Item.PowerSupply' interface. When the 'Present'
735property on the 'xyz.openbmc_project.Inventory.Item' interface on these paths
736change to true, the code will find all fan/PS PELs with the deconfig bit set and
737that location code in the callout list and clear the deconfig flag in the PEL.
738That way, when the code that does the report searches for PELs, it will no
739longer find them.
740
741[1]:
742 https://github.com/openbmc/docs/blob/master/designs/fail-boot-on-hw-error.md