Home
last modified time | relevance | path

Searched full:degree (Results 1 – 25 of 394) sorted by relevance

12345678910>>...16

/openbmc/linux/drivers/gpu/drm/omapdrm/
H A Domap_dmm_tiler.h50 0 0 0 0-degree view Natural view
51 0 0 1 0-degree view with vertical mirror 180-degree view with horizontal mirror
52 0 1 0 0-degree view with horizontal mirror 180-degree view with vertical mirror
53 0 1 1 180-degree view
54 1 0 0 90-degree view with vertical mirror 270-degree view with horizontal mirror
55 1 0 1 270-degree view
56 1 1 0 90-degree view
57 1 1 1 90-degree view with horizontal mirror 270-degree view with vertical mirror
/openbmc/linux/Documentation/hwmon/
H A Damc6821.rst70 0 degree C to 124 degree C in steps of
71 4 degree C. Read it out after writing to get
80 temp2_auto_point1_temp rw Must be between 0 degree C and 63 degree C and
87 0 degree C to 124 degree C in steps
88 of 4 degree C.
H A Dnct7904.rst38 temp1_input Local temperature (1/1000 degree,
39 0.125 degree resolution)
41 temp[2-9]_input CPU temperatures (1/1000 degree,
42 0.125 degree resolution)
H A Dds1621.rst67 degree Celsius to +125 in 0.5 increments. You may convert this into a
83 1.0 degree Celsius to avoid Tout "bouncing", though!
125 - DS1621: +/- 0.5 degree Celsius (from 0 to +70 degrees)
126 - DS1625: +/- 0.5 degree Celsius (from 0 to +70 degrees)
127 - DS1631: +/- 0.5 degree Celsius (from 0 to +70 degrees)
128 - DS1721: +/- 1.0 degree Celsius (from -10 to +85 degrees)
129 - DS1731: +/- 1.0 degree Celsius (from -10 to +85 degrees)
H A Dtmp102.rst23 sensor is accurate to 0.5 degree over the range of -25 to +85 C, and to 1.0
24 degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
H A Dsht21.rst40 0.2 degree Celsius) compared with the SHT21 (2.0% relative humidity,
41 0.3 degree Celsius).
63 humidity and 66 ms for temperature. To keep self heating below 0.1 degree
H A Dtmp401.rst59 Celsius. Resolution of the remote sensor is 0.0625 degree. Local
60 sensor resolution can be set to 0.5, 0.25, 0.125 or 0.0625 degree (not
62 degree).
H A Dsy7636a-hwmon.rst20 - SoC on-die temperature in milli-degree C
26 - SoC on-die temperature (milli-degree C)
H A Dxgene-hwmon.rst19 - SoC on-die temperature in milli-degree C
30 - SoC on-die temperature (milli-degree C)
H A Dadm1031.rst37 degree for the local temperature, 0.125 degree for the remote temperatures.
/openbmc/u-boot/doc/device-tree-bindings/exynos/
H A Dtmu.txt6 - samsung,min-temp : Minimum temperature value (25 degree celsius)
8 - samsung,max-temp : Maximum temperature value (125 degree celsius)
10 - samsung,start-warning : Temperature at which TMU starts giving warning (degree celsius)
11 - samsung,start-tripping : Temperature at which TMU shuts down the system (degree celsius)
13 in case TMU fails to power off (degree celsius)
/openbmc/linux/include/linux/
H A Dpolynomial.h11 * @deg: degree of the term.
13 * @divider: distributed divider per each degree.
26 * @terms: polynomial terms, last term must have degree of 0
H A Dbch.h24 * @ecc_bits: ecc exact size in bits, i.e. generator polynomial degree (<=m*t)
31 * @xi_tab: GF(2^m) base for solving degree 2 polynomial roots
35 * @poly_2t: temporary polynomials of degree 2t
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema-installed/
H A DThermalMetrics.v1_3_2.json160 … "description": "The ambient temperature (in degree Celsius units) of this subsystem.",
162 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
173 … "description": "The exhaust temperature (in degree Celsius units) of this subsystem.",
175 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
186 … "description": "The intake temperature (in degree Celsius units) of this subsystem.",
188 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
199 … "description": "The internal temperature (in degree Celsius units) of this subsystem.",
201 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
331 …"description": "The temperatures (in degree Celsius units) from all related sensors for this devic…
336 …"longDescription": "This property shall contain the temperatures, in degree Celsius units, for thi…
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema/
H A DThermalMetrics.v1_3_2.json160 … "description": "The ambient temperature (in degree Celsius units) of this subsystem.",
162 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
173 … "description": "The exhaust temperature (in degree Celsius units) of this subsystem.",
175 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
186 … "description": "The intake temperature (in degree Celsius units) of this subsystem.",
188 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
199 … "description": "The internal temperature (in degree Celsius units) of this subsystem.",
201 …"longDescription": "This property shall contain the temperature, in degree Celsius units, for the …
331 …"description": "The temperatures (in degree Celsius units) from all related sensors for this devic…
336 …"longDescription": "This property shall contain the temperatures, in degree Celsius units, for thi…
/openbmc/linux/Documentation/devicetree/bindings/spi/
H A Dsamsung,spi-peripheral-props.yaml26 - 1: 90 degree phase shift sampling.
27 - 2: 180 degree phase shift sampling.
28 - 3: 270 degree phase shift sampling.
/openbmc/linux/Documentation/devicetree/bindings/power/supply/
H A Dbattery.yaml91 - description: the temperature in degree Celsius
94 A table providing the temperature in degree Celsius
101 An array containing the temperature in degree Celsius,
163 /* table for -10 degree Celsius */
165 /* table for 0 degree Celsius */
167 /* table for 10 degree Celsius */
/openbmc/linux/Documentation/driver-api/thermal/
H A Dexynos_thermal.rst40 Trimming info for 25 degree Celsius (stored at TRIMINFO register)
41 Temperature code measured at 25 degree Celsius which is unchanged
43 Trimming info for 85 degree Celsius (stored at TRIMINFO register)
44 Temperature code measured at 85 degree Celsius which is unchanged
/openbmc/openbmc/meta-openembedded/meta-oe/recipes-kernel/kernel-selftest/kernel-selftest/
H A Duserfaultfd.patch64 + int rand_deg; /* Degree of random number generator. */
242 + int degree = random_poly_info.degrees[type];
247 + buf->rand_deg = degree;
250 + buf->end_ptr = &state[degree];
281 + int degree;
298 + buf->rand_deg = degree = random_poly_info.degrees[type];
306 + buf->fptr = &new_state[(rear + separation) % degree];
310 + buf->end_ptr = &new_state[degree];
/openbmc/u-boot/include/linux/
H A Dbch.h24 * @ecc_bits: ecc exact size in bits, i.e. generator polynomial degree (<=m*t)
31 * @xi_tab: GF(2^m) base for solving degree 2 polynomial roots
35 * @poly_2t: temporary polynomials of degree 2t
/openbmc/phosphor-webui/app/server-health/controllers/
H A Dsensors-overview-controller.html70 <span class="sensors__tbody-degree" ng-if="sensor.unit == 'C'">&deg;</span>
78 <span class="sensors__tbody-degree" ng-if="sensor.unit == 'C'">&deg;</span>
86 <span class="sensors__tbody-degree" ng-if="sensor.unit == 'C'">&deg;</span>
94 <span class="sensors__tbody-degree" ng-if="sensor.unit == 'C'">&deg;</span>
102 <span class="sensors__tbody-degree" ng-if="sensor.unit == 'C'">&deg;</span>
/openbmc/linux/drivers/mtd/nand/raw/atmel/
H A Dpmecc.c188 /* polynomial degree is the most-significant bit index */ in deg()
199 /* primitive polynomial must be of degree m */ in atmel_pmecc_build_gf_tables()
223 unsigned int poly, degree, table_size; in atmel_pmecc_create_gf_tables() local
227 degree = PMECC_GF_DIMENSION_13; in atmel_pmecc_create_gf_tables()
231 degree = PMECC_GF_DIMENSION_14; in atmel_pmecc_create_gf_tables()
245 ret = atmel_pmecc_build_gf_tables(degree, poly, gf_tables); in atmel_pmecc_create_gf_tables()
440 int degree = get_sectorsize(user) == 512 ? 13 : 14; in atmel_pmecc_substitute()
441 int cw_len = BIT(degree) - 1; in atmel_pmecc_substitute()
460 for (j = 0; j < degree; j++) { in atmel_pmecc_substitute()
486 int degree in atmel_pmecc_get_sigma()
442 int degree = get_sectorsize(user) == 512 ? 13 : 14; atmel_pmecc_substitute() local
488 int degree = get_sectorsize(user) == 512 ? 13 : 14; atmel_pmecc_get_sigma() local
638 int degree = sector_size == 512 ? 13 : 14; atmel_pmecc_err_location() local
[all...]
/openbmc/bmcweb/redfish-core/schema/dmtf/installed/
H A DThermalMetrics_v1.xml80 …<Annotation Term="OData.Description" String="The temperatures (in degree Celsius units) from all r…
81 …ongDescription" String="This property shall contain the temperatures, in degree Celsius units, for…
95 …<Annotation Term="OData.Description" String="The internal temperature (in degree Celsius units) of…
96 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
100 …<Annotation Term="OData.Description" String="The intake temperature (in degree Celsius units) of t…
101 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
105 …<Annotation Term="OData.Description" String="The exhaust temperature (in degree Celsius units) of …
106 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
110 …<Annotation Term="OData.Description" String="The ambient temperature (in degree Celsius units) of …
111 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
/openbmc/bmcweb/redfish-core/schema/dmtf/csdl/
H A DThermalMetrics_v1.xml80 …<Annotation Term="OData.Description" String="The temperatures (in degree Celsius units) from all r…
81 …ongDescription" String="This property shall contain the temperatures, in degree Celsius units, for…
95 …<Annotation Term="OData.Description" String="The internal temperature (in degree Celsius units) of…
96 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
100 …<Annotation Term="OData.Description" String="The intake temperature (in degree Celsius units) of t…
101 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
105 …<Annotation Term="OData.Description" String="The exhaust temperature (in degree Celsius units) of …
106 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
110 …<Annotation Term="OData.Description" String="The ambient temperature (in degree Celsius units) of …
111 …LongDescription" String="This property shall contain the temperature, in degree Celsius units, for…
/openbmc/linux/drivers/iio/gyro/
H A Dadis16080.c176 /* 80 degree = 819, 819 rad = 46925 degree */
181 /* 300 degree = 1230, 1230 rad = 70474 degree */

12345678910>>...16