/openbmc/openbmc/meta-ibm/recipes-phosphor/dbus/ |
H A D | fan-policy.bb | 11 SRC_URI:append:df-openpower = " file://air-cooled.yaml" 15 SRC_URI:remove:p10bmc = "file://air-cooled.yaml" 19 install -D ${UNPACKDIR}/air-cooled.yaml ${D}${config_dir}/air-cooled.yaml 25 FILES:${PN} += "${config_dir}/air-cooled.yaml" 29 FILES:${PN}:remove:p10bmc = "${config_dir}/air-cooled.yaml"
|
/openbmc/phosphor-dbus-interfaces/yaml/xyz/openbmc_project/Inventory/Decorator/ |
H A D | ThermalDirection.interface.yaml | 20 A chassis with the air intake in the back and exhaust out the 24 A chassis with the air intake in the front and exhaust out the 28 A sealed chassis with no air pathway. 31 A chassis with air exhaust on the top.
|
H A D | CoolingType.interface.yaml | 2 Implement properties to indicate the element cooling type (air, water, 8 The element uses air/fans for cooling when set to true.
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/dbus/fan-policy/swift/ |
H A D | air-cooled.yaml | 1 # Air cooled Swift fan policy for PDM. 3 # An air cooled Swift requires a minimum of three functional fan enclosures. 9 'An air cooled Swift has four fan enclosures to monitor.' 73 - name: chassis air cooled 117 properties: chassis air cooled 121 'If this condition passes the chassis is air cooled.' 125 properties: chassis air cooled
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/dbus/fan-policy/witherspoon/ |
H A D | air-cooled.yaml | 1 # Air cooled Witherspoon fan policy for PDM. 3 # An air cooled Witherspoon requires a minimum of three functional fans 11 'An air cooled Witherspoon has four fan enclosures to monitor.' 26 'An air cooled Witherspoon has eight fan rotors to monitor.' 98 - name: chassis air cooled 151 properties: chassis air cooled 155 'If this condition passes the chassis is air cooled.' 159 properties: chassis air cooled
|
/openbmc/phosphor-fan-presence/cooling-type/ |
H A D | main.cpp | 20 bool air = false; in main() local 28 app.add_flag("-a,--air", air, in main() 57 if (air) in main()
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan/swift/obmc/phosphor-fan/ |
H A D | phosphor-cooling-type-0.conf | 2 AIR="--air"
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan/witherspoon/obmc/phosphor-fan/ |
H A D | phosphor-cooling-type-0.conf | 2 AIR="--air"
|
/openbmc/openbmc/poky/bitbake/lib/toaster/toastergui/templates/ |
H A D | landing.html | 17 <p class="top-air"> 25 <p class="top-air"> 32 <div class="alert alert-info lead top-air"> 45 <p class="top-air">
|
/openbmc/phosphor-fan-presence/control/example/ |
H A D | zones.yaml | 15 #example, a fan may only be in zone 0 if it's the air cooled version 17 #case, the fan yaml would have a cooling_profile of 'air' to match 54 # - air
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/ |
H A D | zones.yaml | 6 #Air cooled zones 13 - air
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/witherspoon/ |
H A D | zones.yaml | 6 #Air cooled zones 13 - air
|
/openbmc/dbus-sensors/ |
H A D | meson.options | 14 'exit-air', 17 description: 'Enable exit air sensor.',
|
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema-installed/ |
H A D | ThermalMetrics.v1_3_2.json | 251 "description": "The air flow through the chassis (m^3/min).", 253 …s property shall contain the rate of air flow, in cubic meters per minute units, between the air i… 268 … in kilopascal units, for the difference in pressure between the air intake and the air exhaust of…
|
H A D | PhysicalContext.json | 99 "CoolingSubsystem": "The entire cooling, or air and liquid, subsystem.", 101 "Exhaust": "The air exhaust point or points or region of the chassis.", 110 "Intake": "The air intake point or points or region of the chassis.",
|
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema/ |
H A D | ThermalMetrics.v1_3_2.json | 251 "description": "The air flow through the chassis (m^3/min).", 253 …s property shall contain the rate of air flow, in cubic meters per minute units, between the air i… 268 … in kilopascal units, for the difference in pressure between the air intake and the air exhaust of…
|
H A D | PhysicalContext.json | 99 "CoolingSubsystem": "The entire cooling, or air and liquid, subsystem.", 101 "Exhaust": "The air exhaust point or points or region of the chassis.", 110 "Intake": "The air intake point or points or region of the chassis.",
|
/openbmc/openbmc/meta-ibm/meta-romulus/recipes-phosphor/fans/phosphor-fan-control-zone-config/ |
H A D | zones.yaml | 6 #Air cooled zones
|
/openbmc/openbmc-test-automation/ipmi/ |
H A D | test_ipmi_sensor.robot | 49 # Inlet air temperature(40h) 1 +22 C 50 # Inlet air temperature(40h) 2 +23 C 51 # Inlet air temperature(40h) 3 +22 C 57 Should Contain ${temp_reading} Inlet air temperature 62 ... Inlet air temperature case-insensitive 112 # Inlet air temperature(40h) 1 +22 C 113 # Inlet air temperature(40h) 2 +23 C 114 # Inlet air temperature(40h) 3 +22 C
|
/openbmc/dbus-sensors/src/ |
H A D | meson.build | 120 if get_option('exit-air').allowed() 121 subdir('exit-air')
|
/openbmc/u-boot/configs/ |
H A D | nanopi_neo_air_defconfig | 15 CONFIG_DEFAULT_DEVICE_TREE="sun8i-h3-nanopi-neo-air"
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-fan-config/witherspoon/ |
H A D | fans.yaml | 14 cooling_profile: air
|
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-fan-config/swift/ |
H A D | fans.yaml | 14 cooling_profile: air
|
/openbmc/dbus-sensors/service_files/ |
H A D | xyz.openbmc_project.exitairsensor.service | 2 Description=Exit Air Temp Sensor
|
/openbmc/u-boot/arch/arm/dts/ |
H A D | sun8i-h3-nanopi-neo-air.dts | 50 model = "FriendlyARM NanoPi NEO Air"; 51 compatible = "friendlyarm,nanopi-neo-air", "allwinner,sun8i-h3";
|