1 // SPDX-License-Identifier: GPL-2.0+
2 /*
3 * Copyright (C) 2013-2014 Synopsys, Inc. All rights reserved.
4 */
5
6 #include <config.h>
7 #include <common.h>
8 #include <linux/compiler.h>
9 #include <linux/kernel.h>
10 #include <linux/log2.h>
11 #include <asm/arcregs.h>
12 #include <asm/arc-bcr.h>
13 #include <asm/cache.h>
14
15 /*
16 * [ NOTE 1 ]:
17 * Data cache (L1 D$ or SL$) entire invalidate operation or data cache disable
18 * operation may result in unexpected behavior and data loss even if we flush
19 * data cache right before invalidation. That may happens if we store any context
20 * on stack (like we store BLINK register on stack before function call).
21 * BLINK register is the register where return address is automatically saved
22 * when we do function call with instructions like 'bl'.
23 *
24 * There is the real example:
25 * We may hang in the next code as we store any BLINK register on stack in
26 * invalidate_dcache_all() function.
27 *
28 * void flush_dcache_all() {
29 * __dc_entire_op(OP_FLUSH);
30 * // Other code //
31 * }
32 *
33 * void invalidate_dcache_all() {
34 * __dc_entire_op(OP_INV);
35 * // Other code //
36 * }
37 *
38 * void foo(void) {
39 * flush_dcache_all();
40 * invalidate_dcache_all();
41 * }
42 *
43 * Now let's see what really happens during that code execution:
44 *
45 * foo()
46 * |->> call flush_dcache_all
47 * [return address is saved to BLINK register]
48 * [push BLINK] (save to stack) ![point 1]
49 * |->> call __dc_entire_op(OP_FLUSH)
50 * [return address is saved to BLINK register]
51 * [flush L1 D$]
52 * return [jump to BLINK]
53 * <<------
54 * [other flush_dcache_all code]
55 * [pop BLINK] (get from stack)
56 * return [jump to BLINK]
57 * <<------
58 * |->> call invalidate_dcache_all
59 * [return address is saved to BLINK register]
60 * [push BLINK] (save to stack) ![point 2]
61 * |->> call __dc_entire_op(OP_FLUSH)
62 * [return address is saved to BLINK register]
63 * [invalidate L1 D$] ![point 3]
64 * // Oops!!!
65 * // We lose return address from invalidate_dcache_all function:
66 * // we save it to stack and invalidate L1 D$ after that!
67 * return [jump to BLINK]
68 * <<------
69 * [other invalidate_dcache_all code]
70 * [pop BLINK] (get from stack)
71 * // we don't have this data in L1 dcache as we invalidated it in [point 3]
72 * // so we get it from next memory level (for example DDR memory)
73 * // but in the memory we have value which we save in [point 1], which
74 * // is return address from flush_dcache_all function (instead of
75 * // address from current invalidate_dcache_all function which we
76 * // saved in [point 2] !)
77 * return [jump to BLINK]
78 * <<------
79 * // As BLINK points to invalidate_dcache_all, we call it again and
80 * // loop forever.
81 *
82 * Fortunately we may fix that by using flush & invalidation of D$ with a single
83 * one instruction (instead of flush and invalidation instructions pair) and
84 * enabling force function inline with '__attribute__((always_inline))' gcc
85 * attribute to avoid any function call (and BLINK store) between cache flush
86 * and disable.
87 *
88 *
89 * [ NOTE 2 ]:
90 * As of today we only support the following cache configurations on ARC.
91 * Other configurations may exist in HW (for example, since version 3.0 HS
92 * supports SL$ (L2 system level cache) disable) but we don't support it in SW.
93 * Configuration 1:
94 * ______________________
95 * | |
96 * | ARC CPU |
97 * |______________________|
98 * ___|___ ___|___
99 * | | | |
100 * | L1 I$ | | L1 D$ |
101 * |_______| |_______|
102 * on/off on/off
103 * ___|______________|____
104 * | |
105 * | main memory |
106 * |______________________|
107 *
108 * Configuration 2:
109 * ______________________
110 * | |
111 * | ARC CPU |
112 * |______________________|
113 * ___|___ ___|___
114 * | | | |
115 * | L1 I$ | | L1 D$ |
116 * |_______| |_______|
117 * on/off on/off
118 * ___|______________|____
119 * | |
120 * | L2 (SL$) |
121 * |______________________|
122 * always must be on
123 * ___|______________|____
124 * | |
125 * | main memory |
126 * |______________________|
127 *
128 * Configuration 3:
129 * ______________________
130 * | |
131 * | ARC CPU |
132 * |______________________|
133 * ___|___ ___|___
134 * | | | |
135 * | L1 I$ | | L1 D$ |
136 * |_______| |_______|
137 * on/off must be on
138 * ___|______________|____ _______
139 * | | | |
140 * | L2 (SL$) |-----| IOC |
141 * |______________________| |_______|
142 * always must be on on/off
143 * ___|______________|____
144 * | |
145 * | main memory |
146 * |______________________|
147 */
148
149 DECLARE_GLOBAL_DATA_PTR;
150
151 /* Bit values in IC_CTRL */
152 #define IC_CTRL_CACHE_DISABLE BIT(0)
153
154 /* Bit values in DC_CTRL */
155 #define DC_CTRL_CACHE_DISABLE BIT(0)
156 #define DC_CTRL_INV_MODE_FLUSH BIT(6)
157 #define DC_CTRL_FLUSH_STATUS BIT(8)
158
159 #define OP_INV BIT(0)
160 #define OP_FLUSH BIT(1)
161 #define OP_FLUSH_N_INV (OP_FLUSH | OP_INV)
162
163 /* Bit val in SLC_CONTROL */
164 #define SLC_CTRL_DIS 0x001
165 #define SLC_CTRL_IM 0x040
166 #define SLC_CTRL_BUSY 0x100
167 #define SLC_CTRL_RGN_OP_INV 0x200
168
169 #define CACHE_LINE_MASK (~(gd->arch.l1_line_sz - 1))
170
171 /*
172 * We don't want to use '__always_inline' macro here as it can be redefined
173 * to simple 'inline' in some cases which breaks stuff. See [ NOTE 1 ] for more
174 * details about the reasons we need to use always_inline functions.
175 */
176 #define inlined_cachefunc inline __attribute__((always_inline))
177
178 static inlined_cachefunc void __ic_entire_invalidate(void);
179 static inlined_cachefunc void __dc_entire_op(const int cacheop);
180
pae_exists(void)181 static inline bool pae_exists(void)
182 {
183 /* TODO: should we compare mmu version from BCR and from CONFIG? */
184 #if (CONFIG_ARC_MMU_VER >= 4)
185 union bcr_mmu_4 mmu4;
186
187 mmu4.word = read_aux_reg(ARC_AUX_MMU_BCR);
188
189 if (mmu4.fields.pae)
190 return true;
191 #endif /* (CONFIG_ARC_MMU_VER >= 4) */
192
193 return false;
194 }
195
icache_exists(void)196 static inlined_cachefunc bool icache_exists(void)
197 {
198 union bcr_di_cache ibcr;
199
200 ibcr.word = read_aux_reg(ARC_BCR_IC_BUILD);
201 return !!ibcr.fields.ver;
202 }
203
icache_enabled(void)204 static inlined_cachefunc bool icache_enabled(void)
205 {
206 if (!icache_exists())
207 return false;
208
209 return !(read_aux_reg(ARC_AUX_IC_CTRL) & IC_CTRL_CACHE_DISABLE);
210 }
211
dcache_exists(void)212 static inlined_cachefunc bool dcache_exists(void)
213 {
214 union bcr_di_cache dbcr;
215
216 dbcr.word = read_aux_reg(ARC_BCR_DC_BUILD);
217 return !!dbcr.fields.ver;
218 }
219
dcache_enabled(void)220 static inlined_cachefunc bool dcache_enabled(void)
221 {
222 if (!dcache_exists())
223 return false;
224
225 return !(read_aux_reg(ARC_AUX_DC_CTRL) & DC_CTRL_CACHE_DISABLE);
226 }
227
slc_exists(void)228 static inlined_cachefunc bool slc_exists(void)
229 {
230 if (is_isa_arcv2()) {
231 union bcr_generic sbcr;
232
233 sbcr.word = read_aux_reg(ARC_BCR_SLC);
234 return !!sbcr.fields.ver;
235 }
236
237 return false;
238 }
239
slc_data_bypass(void)240 static inlined_cachefunc bool slc_data_bypass(void)
241 {
242 /*
243 * If L1 data cache is disabled SL$ is bypassed and all load/store
244 * requests are sent directly to main memory.
245 */
246 return !dcache_enabled();
247 }
248
ioc_exists(void)249 static inline bool ioc_exists(void)
250 {
251 if (is_isa_arcv2()) {
252 union bcr_clust_cfg cbcr;
253
254 cbcr.word = read_aux_reg(ARC_BCR_CLUSTER);
255 return cbcr.fields.c;
256 }
257
258 return false;
259 }
260
ioc_enabled(void)261 static inline bool ioc_enabled(void)
262 {
263 /*
264 * We check only CONFIG option instead of IOC HW state check as IOC
265 * must be disabled by default.
266 */
267 if (is_ioc_enabled())
268 return ioc_exists();
269
270 return false;
271 }
272
__slc_entire_op(const int op)273 static inlined_cachefunc void __slc_entire_op(const int op)
274 {
275 unsigned int ctrl;
276
277 if (!slc_exists())
278 return;
279
280 ctrl = read_aux_reg(ARC_AUX_SLC_CTRL);
281
282 if (!(op & OP_FLUSH)) /* i.e. OP_INV */
283 ctrl &= ~SLC_CTRL_IM; /* clear IM: Disable flush before Inv */
284 else
285 ctrl |= SLC_CTRL_IM;
286
287 write_aux_reg(ARC_AUX_SLC_CTRL, ctrl);
288
289 if (op & OP_INV) /* Inv or flush-n-inv use same cmd reg */
290 write_aux_reg(ARC_AUX_SLC_INVALIDATE, 0x1);
291 else
292 write_aux_reg(ARC_AUX_SLC_FLUSH, 0x1);
293
294 /* Make sure "busy" bit reports correct stataus, see STAR 9001165532 */
295 read_aux_reg(ARC_AUX_SLC_CTRL);
296
297 /* Important to wait for flush to complete */
298 while (read_aux_reg(ARC_AUX_SLC_CTRL) & SLC_CTRL_BUSY);
299 }
300
slc_upper_region_init(void)301 static void slc_upper_region_init(void)
302 {
303 /*
304 * ARC_AUX_SLC_RGN_START1 and ARC_AUX_SLC_RGN_END1 register exist
305 * only if PAE exists in current HW. So we had to check pae_exist
306 * before using them.
307 */
308 if (!pae_exists())
309 return;
310
311 /*
312 * ARC_AUX_SLC_RGN_END1 and ARC_AUX_SLC_RGN_START1 are always == 0
313 * as we don't use PAE40.
314 */
315 write_aux_reg(ARC_AUX_SLC_RGN_END1, 0);
316 write_aux_reg(ARC_AUX_SLC_RGN_START1, 0);
317 }
318
__slc_rgn_op(unsigned long paddr,unsigned long sz,const int op)319 static void __slc_rgn_op(unsigned long paddr, unsigned long sz, const int op)
320 {
321 #ifdef CONFIG_ISA_ARCV2
322
323 unsigned int ctrl;
324 unsigned long end;
325
326 if (!slc_exists())
327 return;
328
329 /*
330 * The Region Flush operation is specified by CTRL.RGN_OP[11..9]
331 * - b'000 (default) is Flush,
332 * - b'001 is Invalidate if CTRL.IM == 0
333 * - b'001 is Flush-n-Invalidate if CTRL.IM == 1
334 */
335 ctrl = read_aux_reg(ARC_AUX_SLC_CTRL);
336
337 /* Don't rely on default value of IM bit */
338 if (!(op & OP_FLUSH)) /* i.e. OP_INV */
339 ctrl &= ~SLC_CTRL_IM; /* clear IM: Disable flush before Inv */
340 else
341 ctrl |= SLC_CTRL_IM;
342
343 if (op & OP_INV)
344 ctrl |= SLC_CTRL_RGN_OP_INV; /* Inv or flush-n-inv */
345 else
346 ctrl &= ~SLC_CTRL_RGN_OP_INV;
347
348 write_aux_reg(ARC_AUX_SLC_CTRL, ctrl);
349
350 /*
351 * Lower bits are ignored, no need to clip
352 * END needs to be setup before START (latter triggers the operation)
353 * END can't be same as START, so add (l2_line_sz - 1) to sz
354 */
355 end = paddr + sz + gd->arch.slc_line_sz - 1;
356
357 /*
358 * Upper addresses (ARC_AUX_SLC_RGN_END1 and ARC_AUX_SLC_RGN_START1)
359 * are always == 0 as we don't use PAE40, so we only setup lower ones
360 * (ARC_AUX_SLC_RGN_END and ARC_AUX_SLC_RGN_START)
361 */
362 write_aux_reg(ARC_AUX_SLC_RGN_END, end);
363 write_aux_reg(ARC_AUX_SLC_RGN_START, paddr);
364
365 /* Make sure "busy" bit reports correct stataus, see STAR 9001165532 */
366 read_aux_reg(ARC_AUX_SLC_CTRL);
367
368 while (read_aux_reg(ARC_AUX_SLC_CTRL) & SLC_CTRL_BUSY);
369
370 #endif /* CONFIG_ISA_ARCV2 */
371 }
372
arc_ioc_setup(void)373 static void arc_ioc_setup(void)
374 {
375 /* IOC Aperture start is equal to DDR start */
376 unsigned int ap_base = CONFIG_SYS_SDRAM_BASE;
377 /* IOC Aperture size is equal to DDR size */
378 long ap_size = CONFIG_SYS_SDRAM_SIZE;
379
380 /* Unsupported configuration. See [ NOTE 2 ] for more details. */
381 if (!slc_exists())
382 panic("Try to enable IOC but SLC is not present");
383
384 /* Unsupported configuration. See [ NOTE 2 ] for more details. */
385 if (!dcache_enabled())
386 panic("Try to enable IOC but L1 D$ is disabled");
387
388 if (!is_power_of_2(ap_size) || ap_size < 4096)
389 panic("IOC Aperture size must be power of 2 and bigger 4Kib");
390
391 /* IOC Aperture start must be aligned to the size of the aperture */
392 if (ap_base % ap_size != 0)
393 panic("IOC Aperture start must be aligned to the size of the aperture");
394
395 flush_n_invalidate_dcache_all();
396
397 /*
398 * IOC Aperture size decoded as 2 ^ (SIZE + 2) KB,
399 * so setting 0x11 implies 512M, 0x12 implies 1G...
400 */
401 write_aux_reg(ARC_AUX_IO_COH_AP0_SIZE,
402 order_base_2(ap_size / 1024) - 2);
403
404 write_aux_reg(ARC_AUX_IO_COH_AP0_BASE, ap_base >> 12);
405 write_aux_reg(ARC_AUX_IO_COH_PARTIAL, 1);
406 write_aux_reg(ARC_AUX_IO_COH_ENABLE, 1);
407 }
408
read_decode_cache_bcr_arcv2(void)409 static void read_decode_cache_bcr_arcv2(void)
410 {
411 #ifdef CONFIG_ISA_ARCV2
412
413 union bcr_slc_cfg slc_cfg;
414
415 if (slc_exists()) {
416 slc_cfg.word = read_aux_reg(ARC_AUX_SLC_CONFIG);
417 gd->arch.slc_line_sz = (slc_cfg.fields.lsz == 0) ? 128 : 64;
418
419 /*
420 * We don't support configuration where L1 I$ or L1 D$ is
421 * absent but SL$ exists. See [ NOTE 2 ] for more details.
422 */
423 if (!icache_exists() || !dcache_exists())
424 panic("Unsupported cache configuration: SLC exists but one of L1 caches is absent");
425 }
426
427 #endif /* CONFIG_ISA_ARCV2 */
428 }
429
read_decode_cache_bcr(void)430 void read_decode_cache_bcr(void)
431 {
432 int dc_line_sz = 0, ic_line_sz = 0;
433 union bcr_di_cache ibcr, dbcr;
434
435 /*
436 * We don't care much about I$ line length really as there're
437 * no per-line ops on I$ instead we only do full invalidation of it
438 * on occasion of relocation and right before jumping to the OS.
439 * Still we check insane config with zero-encoded line length in
440 * presense of version field in I$ BCR. Just in case.
441 */
442 ibcr.word = read_aux_reg(ARC_BCR_IC_BUILD);
443 if (ibcr.fields.ver) {
444 ic_line_sz = 8 << ibcr.fields.line_len;
445 if (!ic_line_sz)
446 panic("Instruction exists but line length is 0\n");
447 }
448
449 dbcr.word = read_aux_reg(ARC_BCR_DC_BUILD);
450 if (dbcr.fields.ver) {
451 gd->arch.l1_line_sz = dc_line_sz = 16 << dbcr.fields.line_len;
452 if (!dc_line_sz)
453 panic("Data cache exists but line length is 0\n");
454 }
455 }
456
cache_init(void)457 void cache_init(void)
458 {
459 read_decode_cache_bcr();
460
461 if (is_isa_arcv2())
462 read_decode_cache_bcr_arcv2();
463
464 if (is_isa_arcv2() && ioc_enabled())
465 arc_ioc_setup();
466
467 if (is_isa_arcv2() && slc_exists())
468 slc_upper_region_init();
469 }
470
icache_status(void)471 int icache_status(void)
472 {
473 return icache_enabled();
474 }
475
icache_enable(void)476 void icache_enable(void)
477 {
478 if (icache_exists())
479 write_aux_reg(ARC_AUX_IC_CTRL, read_aux_reg(ARC_AUX_IC_CTRL) &
480 ~IC_CTRL_CACHE_DISABLE);
481 }
482
icache_disable(void)483 void icache_disable(void)
484 {
485 if (!icache_exists())
486 return;
487
488 __ic_entire_invalidate();
489
490 write_aux_reg(ARC_AUX_IC_CTRL, read_aux_reg(ARC_AUX_IC_CTRL) |
491 IC_CTRL_CACHE_DISABLE);
492 }
493
494 /* IC supports only invalidation */
__ic_entire_invalidate(void)495 static inlined_cachefunc void __ic_entire_invalidate(void)
496 {
497 if (!icache_enabled())
498 return;
499
500 /* Any write to IC_IVIC register triggers invalidation of entire I$ */
501 write_aux_reg(ARC_AUX_IC_IVIC, 1);
502 /*
503 * As per ARC HS databook (see chapter 5.3.3.2)
504 * it is required to add 3 NOPs after each write to IC_IVIC.
505 */
506 __builtin_arc_nop();
507 __builtin_arc_nop();
508 __builtin_arc_nop();
509 read_aux_reg(ARC_AUX_IC_CTRL); /* blocks */
510 }
511
invalidate_icache_all(void)512 void invalidate_icache_all(void)
513 {
514 __ic_entire_invalidate();
515
516 /*
517 * If SL$ is bypassed for data it is used only for instructions,
518 * so we need to invalidate it too.
519 * TODO: HS 3.0 supports SLC disable so we need to check slc
520 * enable/disable status here.
521 */
522 if (is_isa_arcv2() && slc_data_bypass())
523 __slc_entire_op(OP_INV);
524 }
525
dcache_status(void)526 int dcache_status(void)
527 {
528 return dcache_enabled();
529 }
530
dcache_enable(void)531 void dcache_enable(void)
532 {
533 if (!dcache_exists())
534 return;
535
536 write_aux_reg(ARC_AUX_DC_CTRL, read_aux_reg(ARC_AUX_DC_CTRL) &
537 ~(DC_CTRL_INV_MODE_FLUSH | DC_CTRL_CACHE_DISABLE));
538 }
539
dcache_disable(void)540 void dcache_disable(void)
541 {
542 if (!dcache_exists())
543 return;
544
545 __dc_entire_op(OP_FLUSH_N_INV);
546
547 /*
548 * As SLC will be bypassed for data after L1 D$ disable we need to
549 * flush it first before L1 D$ disable. Also we invalidate SLC to
550 * avoid any inconsistent data problems after enabling L1 D$ again with
551 * dcache_enable function.
552 */
553 if (is_isa_arcv2())
554 __slc_entire_op(OP_FLUSH_N_INV);
555
556 write_aux_reg(ARC_AUX_DC_CTRL, read_aux_reg(ARC_AUX_DC_CTRL) |
557 DC_CTRL_CACHE_DISABLE);
558 }
559
560 /* Common Helper for Line Operations on D-cache */
__dcache_line_loop(unsigned long paddr,unsigned long sz,const int cacheop)561 static inline void __dcache_line_loop(unsigned long paddr, unsigned long sz,
562 const int cacheop)
563 {
564 unsigned int aux_cmd;
565 int num_lines;
566
567 /* d$ cmd: INV (discard or wback-n-discard) OR FLUSH (wback) */
568 aux_cmd = cacheop & OP_INV ? ARC_AUX_DC_IVDL : ARC_AUX_DC_FLDL;
569
570 sz += paddr & ~CACHE_LINE_MASK;
571 paddr &= CACHE_LINE_MASK;
572
573 num_lines = DIV_ROUND_UP(sz, gd->arch.l1_line_sz);
574
575 while (num_lines-- > 0) {
576 #if (CONFIG_ARC_MMU_VER == 3)
577 write_aux_reg(ARC_AUX_DC_PTAG, paddr);
578 #endif
579 write_aux_reg(aux_cmd, paddr);
580 paddr += gd->arch.l1_line_sz;
581 }
582 }
583
__before_dc_op(const int op)584 static inlined_cachefunc void __before_dc_op(const int op)
585 {
586 unsigned int ctrl;
587
588 ctrl = read_aux_reg(ARC_AUX_DC_CTRL);
589
590 /* IM bit implies flush-n-inv, instead of vanilla inv */
591 if (op == OP_INV)
592 ctrl &= ~DC_CTRL_INV_MODE_FLUSH;
593 else
594 ctrl |= DC_CTRL_INV_MODE_FLUSH;
595
596 write_aux_reg(ARC_AUX_DC_CTRL, ctrl);
597 }
598
__after_dc_op(const int op)599 static inlined_cachefunc void __after_dc_op(const int op)
600 {
601 if (op & OP_FLUSH) /* flush / flush-n-inv both wait */
602 while (read_aux_reg(ARC_AUX_DC_CTRL) & DC_CTRL_FLUSH_STATUS);
603 }
604
__dc_entire_op(const int cacheop)605 static inlined_cachefunc void __dc_entire_op(const int cacheop)
606 {
607 int aux;
608
609 if (!dcache_enabled())
610 return;
611
612 __before_dc_op(cacheop);
613
614 if (cacheop & OP_INV) /* Inv or flush-n-inv use same cmd reg */
615 aux = ARC_AUX_DC_IVDC;
616 else
617 aux = ARC_AUX_DC_FLSH;
618
619 write_aux_reg(aux, 0x1);
620
621 __after_dc_op(cacheop);
622 }
623
__dc_line_op(unsigned long paddr,unsigned long sz,const int cacheop)624 static inline void __dc_line_op(unsigned long paddr, unsigned long sz,
625 const int cacheop)
626 {
627 if (!dcache_enabled())
628 return;
629
630 __before_dc_op(cacheop);
631 __dcache_line_loop(paddr, sz, cacheop);
632 __after_dc_op(cacheop);
633 }
634
invalidate_dcache_range(unsigned long start,unsigned long end)635 void invalidate_dcache_range(unsigned long start, unsigned long end)
636 {
637 if (start >= end)
638 return;
639
640 /*
641 * ARCv1 -> call __dc_line_op
642 * ARCv2 && L1 D$ disabled -> nothing
643 * ARCv2 && L1 D$ enabled && IOC enabled -> nothing
644 * ARCv2 && L1 D$ enabled && no IOC -> call __dc_line_op; call __slc_rgn_op
645 */
646 if (!is_isa_arcv2() || !ioc_enabled())
647 __dc_line_op(start, end - start, OP_INV);
648
649 if (is_isa_arcv2() && !ioc_enabled() && !slc_data_bypass())
650 __slc_rgn_op(start, end - start, OP_INV);
651 }
652
flush_dcache_range(unsigned long start,unsigned long end)653 void flush_dcache_range(unsigned long start, unsigned long end)
654 {
655 if (start >= end)
656 return;
657
658 /*
659 * ARCv1 -> call __dc_line_op
660 * ARCv2 && L1 D$ disabled -> nothing
661 * ARCv2 && L1 D$ enabled && IOC enabled -> nothing
662 * ARCv2 && L1 D$ enabled && no IOC -> call __dc_line_op; call __slc_rgn_op
663 */
664 if (!is_isa_arcv2() || !ioc_enabled())
665 __dc_line_op(start, end - start, OP_FLUSH);
666
667 if (is_isa_arcv2() && !ioc_enabled() && !slc_data_bypass())
668 __slc_rgn_op(start, end - start, OP_FLUSH);
669 }
670
flush_cache(unsigned long start,unsigned long size)671 void flush_cache(unsigned long start, unsigned long size)
672 {
673 flush_dcache_range(start, start + size);
674 }
675
676 /*
677 * As invalidate_dcache_all() is not used in generic U-Boot code and as we
678 * don't need it in arch/arc code alone (invalidate without flush) we implement
679 * flush_n_invalidate_dcache_all (flush and invalidate in 1 operation) because
680 * it's much safer. See [ NOTE 1 ] for more details.
681 */
flush_n_invalidate_dcache_all(void)682 void flush_n_invalidate_dcache_all(void)
683 {
684 __dc_entire_op(OP_FLUSH_N_INV);
685
686 if (is_isa_arcv2() && !slc_data_bypass())
687 __slc_entire_op(OP_FLUSH_N_INV);
688 }
689
flush_dcache_all(void)690 void flush_dcache_all(void)
691 {
692 __dc_entire_op(OP_FLUSH);
693
694 if (is_isa_arcv2() && !slc_data_bypass())
695 __slc_entire_op(OP_FLUSH);
696 }
697
698 /*
699 * This is function to cleanup all caches (and therefore sync I/D caches) which
700 * can be used for cleanup before linux launch or to sync caches during
701 * relocation.
702 */
sync_n_cleanup_cache_all(void)703 void sync_n_cleanup_cache_all(void)
704 {
705 __dc_entire_op(OP_FLUSH_N_INV);
706
707 /*
708 * If SL$ is bypassed for data it is used only for instructions,
709 * and we shouldn't flush it. So invalidate it instead of flush_n_inv.
710 */
711 if (is_isa_arcv2()) {
712 if (slc_data_bypass())
713 __slc_entire_op(OP_INV);
714 else
715 __slc_entire_op(OP_FLUSH_N_INV);
716 }
717
718 __ic_entire_invalidate();
719 }
720