1# PLDM daemon options 2option( 3 'tests', 4 type: 'feature', 5 value: 'enabled', 6 description: 'Build tests' 7) 8 9option( 10 'utilities', 11 type: 'feature', 12 value: 'enabled', 13 description: 'Enable debug utilities' 14) 15 16option( 17 'libpldmresponder', 18 type: 'feature', 19 value: 'enabled', 20 description: 'Enable libpldmresponder' 21) 22 23option( 24 'systemd', 25 type: 'feature', 26 value: 'enabled', 27 description: 'Include systemd support' 28) 29 30option( 31 'transport-implementation', 32 type: 'combo', 33 choices: ['mctp-demux', 'af-mctp'], 34 description: 'transport via af-mctp or mctp-demux' 35) 36 37# As per PLDM spec DSP0240 version 1.1.0, in Timing Specification for PLDM messages (Table 6), 38# the instance ID for a given response will expire and become reusable if a response has not been 39# received within a maximum of 6 seconds after a request is sent. By setting the dbus timeout 40# value to 5 seconds we ensure that PLDM does not wait for a response from a dbus call even after 41# the instance ID has expired. If the option is set to 5 seconds, any dbus call originated from 42# PLDM daemon will timeout after 5 seconds. 43option( 44 'dbus-timeout-value', 45 type: 'integer', 46 min: 3, 47 max: 10, 48 value: 5, 49 description: '''The amount of time pldm waits to get a response for a dbus 50 message before timing out''' 51) 52 53option( 54 'heartbeat-timeout-seconds', 55 type: 'integer', 56 value: 120, 57 description: '''The amount of time host waits for BMC to respond to pings 58 from host, as part of host-bmc surveillance''' 59) 60 61# Flight Recorder for PLDM Daemon 62option( 63 'flightrecorder-max-entries', 64 type:'integer', 65 min:0, 66 max:30, 67 value: 10, 68 description: '''The max number of pldm messages that can be stored in the 69 recorder, this feature will be disabled if it is set to 0''' 70) 71 72# PLDM Daemon Terminus options 73option( 74 'terminus-id', 75 type:'integer', 76 min:0, 77 max: 255, 78 value:1, 79 description: '''The terminus id value of the device that is running this 80 pldm stack''' 81) 82 83option( 84 'terminus-handle', 85 type:'integer', 86 min:0, 87 max:65535, 88 value:1, 89 description: '''The terminus handle value of the device that is running this 90 pldm stack''' 91) 92 93# Timing specification options for PLDM messages 94option( 95 'number-of-request-retries', 96 type: 'integer', 97 min: 2, 98 max: 30, 99 value: 2, 100 description: '''The number of times a requester is obligated to retry a 101 request''' 102) 103 104option( 105 'instance-id-expiration-interval', 106 type: 'integer', 107 min: 5, 108 max: 6, 109 value: 5, 110 description: 'Instance ID expiration interval in seconds' 111) 112 113# Default response-time-out set to 2 seconds to facilitate a minimum retry of 114# the request of 2. 115option( 116 'response-time-out', 117 type: 'integer', 118 min: 300, 119 max: 4800, 120 value: 2000, 121 description: '''The amount of time a requester has to wait for a response 122 message in milliseconds''' 123) 124 125# Firmware update configuration parameters 126option( 127 'maximum-transfer-size', 128 type: 'integer', 129 min: 16, 130 max: 4294967295, 131 value: 4096, 132 description: '''Maximum size in bytes of the variable payload allowed to be 133 requested by the FD, via RequestFirmwareData command''' 134) 135 136# Bios Attributes option 137option( 138 'system-specific-bios-json', 139 type : 'feature', 140 value: 'disabled', 141 description : 'Support for different set of bios attributes for different types of systems' 142) 143 144# PLDM Soft Power off options 145option( 146 'softoff', 147 type: 'feature', 148 value: 'enabled', 149 description: 'Build soft power off application' 150) 151 152option( 153 'softoff-timeout-seconds', 154 type: 'integer', 155 value: 7200, 156 description: 'softoff: Time to wait for host to gracefully shutdown' 157) 158 159# Vendor Specific Options 160 161## OEM IBM Options 162option( 163 'oem-ibm', 164 type: 'feature', 165 value: 'enabled', 166 description: 'Enable IBM OEM PLDM' 167) 168 169option( 170 'oem-ibm-dma-maxsize', 171 type: 'integer', 172 min:4096, 173 max: 16773120, 174 value: 8384512, 175 description: 'OEM-IBM: max DMA size' 176) 177