Searched refs:enclosure (Results 1 – 20 of 20) sorted by relevance
5 The number of `sensors` that must be deemed nonfunctional for the fan enclosure7 meaning the fan enclosure will not be set to nonfunctional based on the
5 An array of sensor objects that make up the fan enclosure object. The sensors
78 em_message_type: (RO) Displays the current enclosure management104 (RW) Allows access to AHCI EM (enclosure management) buffer119 (RO) Displays supported enclosure management message types.
3 DESCRIPTION = "Intel SGPIO enclosure management utility"
37 -# Intel SGPIO enclosure management utility89 +# Intel SGPIO enclosure management utility
127 int enclosure_add_device(struct enclosure_device *enclosure, int component,
22 obj-$(CONFIG_ENCLOSURE_SERVICES) += enclosure.o
164 or a SCSI enclosure device (SES) to use these services.
54 [Documentation] Verify enclosure LEDs are on and there's an error log.56 # Both enclosure LEDs should now be On.76 ... Fail msg=Expecting both enclosure LEDs to be ${state}.375 # an enclosure LED will light. The other fans should speed up.
81 # an enclosure LED will light. The other fans should speed up.
119 struct mptsas_enclosure *enclosure, u32 form, u32 form_specific);1371 mptsas_sas_enclosure_pg0(MPT_ADAPTER *ioc, struct mptsas_enclosure *enclosure, in mptsas_sas_enclosure_pg0() argument1418 enclosure->enclosure_logical_id = le64_to_cpu(le_identifier); in mptsas_sas_enclosure_pg0()1419 enclosure->enclosure_handle = le16_to_cpu(buffer->EnclosureHandle); in mptsas_sas_enclosure_pg0()1420 enclosure->flags = le16_to_cpu(buffer->Flags); in mptsas_sas_enclosure_pg0()1421 enclosure->num_slot = le16_to_cpu(buffer->NumSlots); in mptsas_sas_enclosure_pg0()1422 enclosure->start_slot = le16_to_cpu(buffer->StartSlot); in mptsas_sas_enclosure_pg0()1423 enclosure->start_id = buffer->StartTargetID; in mptsas_sas_enclosure_pg0()1424 enclosure->start_channel = buffer->StartBus; in mptsas_sas_enclosure_pg0()1425 enclosure->sep_id = buffer->SEPTargetID; in mptsas_sas_enclosure_pg0()[all …]
86 would result in blinking the front and rear Identify LEDs of the enclosure.
33 - Represents an enclosure that can be independently powered off and on by the
56 function enclosure. While the IOMMU may be able to distinguish57 between devices within the enclosure, the enclosure may not require
1004 label = "enclosure-id-led";1020 label = "enclosure-fault-rollup-led";
173 enclosure services device.
448 * Added new fields in SAS Device Page 2 for enclosure
184 it has an enclosure device. Selecting this option will just allow185 certain enclosure conditions to be reported and is not required.
[all...]