a31ceb91 |
| 21-Jul-2021 |
Manojkiran Eda <manojkiran.eda@gmail.com> |
oem_ibm: Add Slot enable infrastructure in BMC
With this commit PDRs are created for each of these PCIe slots and adapters which have a corresponding entry in the entity associate map. The sensor/ef
oem_ibm: Add Slot enable infrastructure in BMC
With this commit PDRs are created for each of these PCIe slots and adapters which have a corresponding entry in the entity associate map. The sensor/effector states are monitored and accordingly D-Bus calls are sent for enabling a slot, process property change of a PCIe slot, etc.
Tested By: SIMICS power on/off and reset reload.
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmail.com> Change-Id: I51b79b75c909ddf2cc29872fec6aa01c2d56b418
show more ...
|
#
16c2a0a0 |
| 16-Aug-2024 |
Patrick Williams <patrick@stwcx.xyz> |
clang-format: re-format for clang-18
clang-format-18 isn't compatible with the clang-format-17 output, so we need to reformat the code with the latest version. The way clang-18 handles lambda forma
clang-format: re-format for clang-18
clang-format-18 isn't compatible with the clang-format-17 output, so we need to reformat the code with the latest version. The way clang-18 handles lambda formatting also changed, so we have made changes to the organization default style format to better handle lambda formatting.
See I5e08687e696dd240402a2780158664b7113def0e for updated style. See Iea0776aaa7edd483fa395e23de25ebf5a6288f71 for clang-18 enablement.
Change-Id: I8c84201cb2343a8c8a5507a49de0721a1bee7063 Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
show more ...
|
#
928e87fa |
| 31-Jul-2024 |
Pavithra Barithaya <pavithrabarithaya07@gmail.com> |
clang-diagnostic error: undeclared identifier
Clang was throwing errors like 'use of undeclared identifier', 'unknown type name' due to missing namespace declarations.
Change-Id: If26471aed22be4706
clang-diagnostic error: undeclared identifier
Clang was throwing errors like 'use of undeclared identifier', 'unknown type name' due to missing namespace declarations.
Change-Id: If26471aed22be470680175c31a916a4184e30bd2 Signed-off-by: Pavithra Barithaya <pavithrabarithaya07@gmail.com>
show more ...
|
#
eb43d6c8 |
| 01-May-2024 |
Kamalkumar Patel <kamalkumar.patel@ibm.com> |
Add support for the coreCount property in DBus
This commit introduces support for counting the number of CPU cores during BMC power-on and populates this information to a DBus property named coreCou
Add support for the coreCount property in DBus
This commit introduces support for counting the number of CPU cores during BMC power-on and populates this information to a DBus property named coreCount. Upon BMC power-on, the remote terminus detects the number of CPU cores and send this data and PLDM will updates the coreCount property accordingly.
Tested: tested on simulator for hosting DBus property
Change-Id: I37adbe399414fcff3f089fb819349ca4bb537edd Signed-off-by: Kamalkumar Patel <kamalkumar.patel@ibm.com>
show more ...
|
#
b49b7d80 |
| 08-Feb-2021 |
George Liu <liuxiwei@inspur.com> |
oem-ibm: Implement Host lamp test interface
IBM has a feature called LampTest and what it does is this: - BMC would set the state of LEDs to [ON] on all the BMC accessible LEDs. - For LEDs t
oem-ibm: Implement Host lamp test interface
IBM has a feature called LampTest and what it does is this: - BMC would set the state of LEDs to [ON] on all the BMC accessible LEDs. - For LEDs that are not accessible by BMC, a message is sent to the Host, so that the Host can exercise all the LEDs on the connected drawers and anything else that the BMC does not have access to.
This commit adds support to send message to Host when BMC has to tell the Host to exercise LEDs accessible by host.
When Host sees the effector is set, it goes ahead and turns [ON] all the LEDs for a specified time and automatically restores the states at timer expiration. BMC does not have to tell the Host to stop the test and it is part of Host's lamp test requirement.
TESTED: By setting the asserted property of the LED groups object
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/lamp_test xyz.openbmc_project.Led.Group Asserted b true
And verifying that the setEffecterStates call was made to the remote state effecter to turn on all LEDs
Signed-off-by: George Liu <liuxiwei@inspur.com> Change-Id: I990dce28d3017f20c73ff9029fced0e7ac84868f
show more ...
|
#
41ca40dc |
| 19-Jun-2024 |
Andrew Jeffery <andrew@codeconstruct.com.au> |
pldm: Use system include directives for libpldm headers
libpldm is now an external dependency rather than an in-tree library. Adjust the includes accordingly.
Change-Id: I97218ec9cf7ffb7afa98e78c01
pldm: Use system include directives for libpldm headers
libpldm is now an external dependency rather than an in-tree library. Adjust the includes accordingly.
Change-Id: I97218ec9cf7ffb7afa98e78c01dc9d030271c3f4 Signed-off-by: Andrew Jeffery <andrew@codeconstruct.com.au>
show more ...
|
#
a881c170 |
| 21-Jun-2021 |
George Liu <liuxiwei@inspur.com> |
Reduce multiple oem_ibm entry points in pldmd
Abstract the custom method of `OEM-IBM` into the oem-ibm.hpp file to prevent the continuous increase of custom code and reduce multiple `OEM-IBM` entry
Reduce multiple oem_ibm entry points in pldmd
Abstract the custom method of `OEM-IBM` into the oem-ibm.hpp file to prevent the continuous increase of custom code and reduce multiple `OEM-IBM` entry points in pldmd.
Tested: enabled oem-ibm and built pldm successfully.
Signed-off-by: George Liu <liuxiwei@inspur.com> Change-Id: Ieddb8d12281553e70bdb1c333bd29425c9d14fb0