b4ef4310 |
| 01-Feb-2024 |
Kamalkumar Patel <kamalkumar.patel@ibm.com> |
Adding json support for pdr generation
- Adding json files for pdr generation based on system type.
- In previous scenario pdr generating based on default configuration but now it will also generat
Adding json support for pdr generation
- Adding json files for pdr generation based on system type.
- In previous scenario pdr generating based on default configuration but now it will also generate platform specific pdr.
Change-Id: Ia36dc6bf90fe97eea3ed45880e464fe32083bf0d Signed-off-by: Kamalkumar Patel <kamalkumar.patel@ibm.com>
show more ...
|
#
391ca890 |
| 02-Mar-2023 |
Andrew Geissler <geissonator@yahoo.com> |
scheduled_host_transition: new object path
The D-Bus path for the ScheduledTime property had to change. The details of this can be found over in the change:
https://gerrit.openbmc.org/c/openbmc/p
scheduled_host_transition: new object path
The D-Bus path for the ScheduledTime property had to change. The details of this can be found over in the change:
https://gerrit.openbmc.org/c/openbmc/phosphor-state-manager/+/61361
Update PLDM to utilize this new object path.
Signed-off-by: Andrew Geissler <geissonator@yahoo.com> Change-Id: I89fdb603730ea3569db03d136a31fef0988cd5bb
show more ...
|
#
b3ab5456 |
| 16-Feb-2023 |
Pavithra Barithaya <pavithra.b@ibm.com> |
PLDM:Adding max settable value for boot counter effecter
This commit adds the maximum settable value for the boot counter numeric effecter. The value is set to the current default value as per the P
PLDM:Adding max settable value for boot counter effecter
This commit adds the maximum settable value for the boot counter numeric effecter. The value is set to the current default value as per the PDI - https://github.com/openbmc/phosphor-dbus-interfaces/blob/master/yaml/xyz /openbmc_project/Control/Boot/RebootAttempts.interface.yaml#L13
Change-Id: Id87e1f6659abf6ac337c8ef385bdf4a9cd204def Signed-off-by: Pavithra Barithaya <pavithra.b@ibm.com>
show more ...
|
#
3618064e |
| 08-Dec-2022 |
Patrick Williams <patrick@stwcx.xyz> |
prettier: re-format
Prettier is enabled in openbmc-build-scripts on Markdown, JSON, and YAML files to have consistent formatting for these file types. Re-run the formatter on the whole repository.
prettier: re-format
Prettier is enabled in openbmc-build-scripts on Markdown, JSON, and YAML files to have consistent formatting for these file types. Re-run the formatter on the whole repository.
Change-Id: I0d25f27a5e449578967915d9f570cc29246927d7 Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
show more ...
|
#
db49e0d3 |
| 01-Mar-2022 |
Manojkiran Eda <manojkiran.eda@gmail.com> |
Fix support for Graceful restart effecter
The termination status effecter when set to Graceful restart state should request the state manager to start the GracefulWarmReboot NOT the ForceWarmReboot.
Fix support for Graceful restart effecter
The termination status effecter when set to Graceful restart state should request the state manager to start the GracefulWarmReboot NOT the ForceWarmReboot.
ForeWarmReboot target would not trigger the pldm-softoff application, so it forcefully shuts down the host rather than waiting for it to acknowledge.
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmail.com> Change-Id: I769dfc57a34e0938f3ca317db0eca8d6b85e7566
show more ...
|
#
db436127 |
| 20-Oct-2021 |
Sagar Srinivas <sagar.srinivas@ibm.com> |
Fix for "Unknown PLDM Entity Type in Numeric Effecter PDR"
Signed-off-by: Sagar Srinivas <sagar.srinivas@ibm.com> Change-Id: I35bf0ca8c2e6555900444143c3d4d9e98157befb
|
#
51290652 |
| 06-Dec-2021 |
Manojkiran Eda <manojkiran.eda@gmail.com> |
Change entity type of dimm from 142 to 66
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmail.com> Change-Id: Ib1272d1c648d9540665ce746777d3eeb92f2d54b
|
#
ae6a4811 |
| 15-Nov-2021 |
Manojkiran Eda <manojkiran.eda@gmail.com> |
Fix the property type error
a114c1075310e5fa24211a4796fe1ed25b828d69 introduced a bug, it seems like a typo, this commit would fix it.
Resolves the following error during power on : Unknown D-Bus p
Fix the property type error
a114c1075310e5fa24211a4796fe1ed25b828d69 introduced a bug, it seems like a typo, this commit would fix it.
Resolves the following error during power on : Unknown D-Bus property type, TYPE=Functional
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmail.com> Change-Id: I7269f3f204e339ad4b5bb2887dde5d638736cd48
show more ...
|
#
bdf56f04 |
| 02-Aug-2021 |
Pavithra Barithaya <pavithra.b@ibm.com> |
PLDM: effecter PDRs support for Slot PowerState
This commit contains the addition of effecter PDRs for the slot power state. Effecters for all the slots are mapped to the interface defined here - ht
PLDM: effecter PDRs support for Slot PowerState
This commit contains the addition of effecter PDRs for the slot power state. Effecters for all the slots are mapped to the interface defined here - https://gerrit.openbmc-project.xyz/c/openbmc/ phosphor-dbus-interfaces/+/45372
Signed-off-by: Pavithra Barithaya <pavithra.b@ibm.com> Change-Id: Ie578c6e53d4ffdfe33a4c11a2c484d92d243bdb8
show more ...
|
#
97296e03 |
| 26-Aug-2021 |
Sagar Srinivas <sagar.srinivas@ibm.com> |
pldm: Change Container IDs of Sensors and Effecters
This commit adds change to the container IDs of few PDRs which had 0 as container ID in the current PDR repository.
Signed-off-by: Sagar Srinivas
pldm: Change Container IDs of Sensors and Effecters
This commit adds change to the container IDs of few PDRs which had 0 as container ID in the current PDR repository.
Signed-off-by: Sagar Srinivas <sagar.srinivas@ibm.com> Change-Id: Ia390054580b14bde736a3360fe029fd767da227f
show more ...
|
#
a114c107 |
| 13-Aug-2021 |
Sridevi Ramesh <sridevra@in.ibm.com> |
PDR: Add effecter support for fault LEDS.
Also, contains update for card, dimm and CPU entity info for identify effecter LED.
Tested Result:
1. Example for fault LED: =========================
pl
PDR: Add effecter support for fault LEDS.
Also, contains update for card, dimm and CPU entity info for identify effecter LED.
Tested Result:
1. Example for fault LED: =========================
pldmtool platform getpdr -d 193 { "nextRecordHandle": 194, "responseCount": 29, "recordHandle": 193, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 103, "entityType": "[Physical] Chassis front panel board(control panel)", "entityInstanceNumber": 1, "containerID": 3, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "Operational Fault Status(10)", "possibleStatesSize[0]": 1, "possibleStates[0]": [ "Normal(1)", "Stressed(2)" ] }
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/base_op_panel_blyth xyz.openbmc_project.State.Decorator.OperationalStatus Functional b true
pldmtool platform SetStateEffecterStates -i 103 -c 1 -d 1 2 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/base_op_panel_blyth xyz.openbmc_project.State.Decorator.OperationalStatus Functional b false
l platform getpdr -d 415 { "nextRecordHandle": 416, "responseCount": 29, "recordHandle": 415, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 120, "entityType": "[Physical] Memory Chip", "entityInstanceNumber": 1, "containerID": 3, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "Operational Fault Status(10)", "possibleStatesSize[0]": 1, "possibleStates[0]": [ "Normal(1)", "Stressed(2)" ] }
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/dimm0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b false
pldmtool platform SetStateEffecterStates -i 120 -c 1 -d 1 1 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/dimm0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b true
2. Example for dimm update for identify effecter ====================================================
Set Memory Chip -1 (Identify State - effecter) and verify with corresponding Memory chip -1 (Identify State - sensor)
pldmtool platform GetStateSensorReadings -i 24 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" } pldmtool platform SetStateEffecterStates -i 21 -c 1 -d 1 1 { "Response": "SUCCESS" } pldmtool platform GetStateSensorReadings -i 24 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Normal"
3. Example for cable card update for identify effecter ======================================================
pldmtool platform getpdr -d 305 { "nextRecordHandle": 306, "responseCount": 29, "recordHandle": 305, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 10, "entityType": "[Physical] Connector", "entityInstanceNumber": 1, "containerID": 10, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "Identify State(17)", "possibleStatesSize[0]": 1, "possibleStates[0]": [ "Identify State Unasserted(1)", "Identify State Asserted(2)" ] }
pldmtool platform GetStateSensorReadings -i 13 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Normal" }
pldmtool platform SetStateEffecterStates -i 10 -c 1 -d 1 2 { "Response": "SUCCESS" }
pldmtool platform GetStateSensorReadings -i 13 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
4. Example for CPU update for identify LED ======================================
Set CPU -1 (Identify State - effecter) and verify with corresponding CPU -1 (Identify State - sensor)
pldmtool platform GetStateSensorReadings -i 15 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Normal" }
pldmtool platform SetStateEffecterStates -i 12 -c 1 -d 1 2 { "Response": "SUCCESS" }
pldmtool platform GetStateSensorReadings -i 15 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
5. Example for CPU fault LED ============================
pldmtool platform getpdr -d 205 { "nextRecordHandle": 206, "responseCount": 29, "recordHandle": 205, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 115, "entityType": "[Physical] Processor", "entityInstanceNumber": 3, "containerID": 4, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "Operational Fault Status(10)", "possibleStatesSize[0]": 1, "possibleStates[0]": [ "Normal(1)", "Stressed(2)" ] }
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/dcm1/cpu0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b true
pldmtool platform SetStateEffecterStates -i 115 -c 1 -d 1 2 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/dcm1/cpu0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b false
Change-Id: I2ad28d985fe190b3bbfbca3e2ed5347b05851ffb Signed-off-by: Sridevi Ramesh <sridevra@in.ibm.com>
show more ...
|
#
2e30eb1a |
| 06-Jul-2021 |
Sridevi Ramesh <sridevra@in.ibm.com> |
pdr: Sensor support for various fault LEDS.
Also, added powersupply 2 and 3 support in 11.json
In this commit sensor fault LEDs support is added for connectors, cablecard, processor, dasd_pyramid,
pdr: Sensor support for various fault LEDS.
Also, added powersupply 2 and 3 support in 11.json
In this commit sensor fault LEDs support is added for connectors, cablecard, processor, dasd_pyramid, ddimm, nvme, pcieslot, planar, battery and tpm_wilson.
Testing Result: Note: Test results are mentioned based on the random LED assert true/false operation for the specific LED type.
processor ==========
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/cpu0_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool platform GetStateSensorReadings -i 114 -r 1 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
Power Converter ==============
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/cpu1_vrm0_fault xyz.openbmc_project.Led.Group Asserted b false pldmtool platform GetStateSensorReadings -i 117 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Normal" }
Drive backplane ====================
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/dasd_pyramid0_fault xyz.openbmc_project.Led.Group Asserted b true pldmtool platform GetStateSensorReadings -i 118 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
System Board =================
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/planar_fault xyz.openbmc_project.Led.Group Asserted b false pldmtool platform GetStateSensorReadings -i 196 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Normal" }
Battery =========
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/rtc_battery_fault xyz.openbmc_project.Led.Group Asserted b false pldmtool platform GetStateSensorReadings -i 201 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Normal" }
power supply ==========
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/powersupply3_fault xyz.openbmc_project.Led.Group Asserted b true pldmtool platform GetStateSensorReadings -i 200 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
Dimm =========
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/ddimm2_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool platform GetStateSensorReadings -i 123 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
NVMe ======
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/nvme23_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool platform GetStateSensorReadings -i 183 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
PCIe slot =============
busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/pcieslot0_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool platform GetStateSensorReadings -i 184 -r 0 { "compositeSensorCount": 1, "sensorOpState[0]": "Sensor Enabled", "presentState[0]": "Sensor Normal", "previousState[0]": "Sensor Unknown", "eventState[0]": "Sensor Warning" }
Change-Id: I795b075dd6cb3d18e6d8243b4540d2f0bb64b80b Signed-off-by: Sridevi Ramesh <sridevra@in.ibm.com>
show more ...
|
#
5f4aec09 |
| 23-Apr-2021 |
Pavithra Barithaya <pavithra.b@ibm.com> |
PLDM: Change rate_unit field to None
This commit has the change to the rate_unit field of a numeric effecter for ScheduledHostTransition. rate_unit was “per second” earlier and TPO epoch time is sen
PLDM: Change rate_unit field to None
This commit has the change to the rate_unit field of a numeric effecter for ScheduledHostTransition. rate_unit was “per second” earlier and TPO epoch time is sent as seconds so it becomes seconds per second which doesn't make sense.
Signed-off-by: Pavithra Barithaya <pavithra.b@ibm.com> Change-Id: I09bec56a2488126103fbd154449bc71f60f6275a
show more ...
|
#
b3dbb6e8 |
| 21-May-2021 |
Pavithra Barithaya <pavithra.b@ibm.com> |
PLDM: Remove Boot Progress entry from 11.json
Phyp is using a sensor to communicate the boot progress state changes to pldm.This commit verifies that and removes the Boot Progress entry from 11.json
PLDM: Remove Boot Progress entry from 11.json
Phyp is using a sensor to communicate the boot progress state changes to pldm.This commit verifies that and removes the Boot Progress entry from 11.json which was used earlier.
Signed-off-by: Pavithra Barithaya <pavithra.b@ibm.com> Change-Id: Ic90c38eaf5bcb9210072a69f34d03dc7c662f7a4
show more ...
|
#
06347d79 |
| 27-May-2021 |
Jayashankar Padath <jayashankar.padath@in.ibm.com> |
pdr: sensor/effecter support for power supply fault leds
This is to support sensor/effecter pdrs for power supply fault leds.
Tested By:
EFFECTER (Power Supply 0):
pldmtool platform GetPDR -d 251
pdr: sensor/effecter support for power supply fault leds
This is to support sensor/effecter pdrs for power supply fault leds.
Tested By:
EFFECTER (Power Supply 0):
pldmtool platform GetPDR -d 251 { "nextRecordHandle": 252, "responseCount": 29, "recordHandle": 251, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 108, "entityType": "Power Supply", "entityInstanceNumber": 1, "containerID": 3, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set Fault On: pldmtool raw -d 0x80 0x02 0x39 0x6C 0x00 0x01 0x01 0x01 Request Message: 08 01 80 02 39 6c 00 01 01 01 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b false
Set Fault Off: pldmtool raw -d 0x80 0x02 0x39 0x6C 0x00 0x01 0x01 0x02 Request Message: 08 01 80 02 39 6c 00 01 01 02 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b true
SENSOR (Power Supply 1):
pldmtool platform GetPDR -d 143 { "nextRecordHandle": 144, "responseCount": 27, "recordHandle": 143, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 111, "entityType": "Power Supply", "entityInstanceNumber": 2, "containerID": 3, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set Fault On: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/powersupply1_fault xyz.openbmc_project.Led.Group Asserted b false
pldmtool raw --data 0x80 0x02 0x21 0x6F 0x00 0x01 0x00 Request Message: 08 01 80 02 21 6f 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
Set Fault Off: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/powersupply1_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool raw --data 0x80 0x02 0x21 0x6F 0x00 0x01 0x00 Request Message: 08 01 80 02 21 6f 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
Signed-off-by: Jayashankar Padath <jayashankar.padath@in.ibm.com> Change-Id: I31b90172a3c891c83f2e66d804599367c2879fa3
show more ...
|
#
2f4f2202 |
| 20-May-2021 |
Jayashankar Padath <jayashankar.padath@in.ibm.com> |
pdr: dimm identify leds sensor/effecter support
This commit contains the addition of sensor/effecter pdrs for dimm identify leds. Also updated the entity instance numbers for enclosure identify and
pdr: dimm identify leds sensor/effecter support
This commit contains the addition of sensor/effecter pdrs for dimm identify leds. Also updated the entity instance numbers for enclosure identify and enclosure fault leds.
Testing Result:
SENSOR(dimm0):
pldmtool platform GetPDR -d 43 { "nextRecordHandle": 44, "responseCount": 27, "recordHandle": 43, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 24, "entityType": "142(OEM)", "entityInstanceNumber": 1, "containerID": 3, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/ddimm0_identify xyz.openbmc_project.Led.Group Asserted b true
pldmtool raw --data 0x80 0x02 0x21 0x18 0x00 0x01 0x00 Request Message: 08 01 80 02 21 18 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
Set Off: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/ddimm0_identify xyz.openbmc_project.Led.Group Asserted b false
pldmtool raw --data 0x80 0x02 0x21 0x18 0x00 0x01 0x00 Request Message: 08 01 80 02 21 18 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
EFFECTER(dimm31):
pldmtool platform GetPDR -d 181 { "nextRecordHandle": 182, "responseCount": 29, "recordHandle": 181, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 53, "entityType": "142(OEM)", "entityInstanceNumber": 26, "containerID": 3, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: pldmtool platform SetStateEffecterStates -i 53 -c 1 -d 1 2 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/ddimm31_identify xyz.openbmc_project.Led.Group Asserted b true
Set Off: pldmtool platform SetStateEffecterStates -i 53 -c 1 -d 1 1 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/ddimm31_identify xyz.openbmc_project.Led.Group Asserted b false
Signed-off-by: Jayashankar Padath <jayashankar.padath@in.ibm.com> Change-Id: I2549eb2f8409755f5821dbdd91e75e86e40d34e8
show more ...
|
#
8dd6fa1b |
| 02-Jun-2021 |
George Liu <liuxiwei@inspur.com> |
pdr: Fix property values corresponding to sensor states
According to: DSP0249_1.1.0 Table 1(Set ID: 17) -------------------------------------------------------------- |17: | Identify State | For
pdr: Fix property values corresponding to sensor states
According to: DSP0249_1.1.0 Table 1(Set ID: 17) -------------------------------------------------------------- |17: | Identify State | For entities that have an identify| | | | function, such as LEDs. | -------------------------------------------------------------- | | 1: Identity State | The entity's identify function is | | | Unasserted | not asserted. | | | 2: Identify State | The entity's identity function is | | | Asserted | asserted. | --------------------------------------------------------------
So states [1, 2] => [false, true]
Signed-off-by: George Liu <liuxiwei@inspur.com> Change-Id: I104fea89d17e4dee4a60732e9f16bec1973f1e7a
show more ...
|
#
144ef2bd |
| 10-May-2021 |
Jayashankar Padath <jayashankar.padath@in.ibm.com> |
pdr: Sensor/Effecter support for identify leds
This commit contains the addition of sensor/effecter pdrs for remaining supported identify leds like cable cards, dasd backplane, nvme drives, pcie slo
pdr: Sensor/Effecter support for identify leds
This commit contains the addition of sensor/effecter pdrs for remaining supported identify leds like cable cards, dasd backplane, nvme drives, pcie slots, planar, powersupplys and the tod battery.
Testing Result:
EFFECTERS:
1) pldmtool platform GetPDR -d 26 { "nextRecordHandle": 27, "responseCount": 29, "recordHandle": 26, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 5, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: pldmtool platform SetStateEffecterStates -i 5 -c 1 -d 1 1 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/cablecard10_cxp_bot_identify xyz.openbmc_project.Led.Group Asserted b true
Set Off: pldmtool platform SetStateEffecterStates -i 5 -c 1 -d 1 2 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/cablecard10_cxp_bot_identify xyz.openbmc_project.Led.Group Asserted b false
2) pldmtool platform GetPDR -d 66 { "nextRecordHandle": 67, "responseCount": 29, "recordHandle": 66, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 45, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: pldmtool platform SetStateEffecterStates -i 45 -c 1 -d 1 1 { "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/rtc_battery_identify xyz.openbmc_project.Led.Group Asserted b true
Set Off: pldmtool platform SetStateEffecterStates -i 45 -c 1 -d 1 2
{ "Response": "SUCCESS" }
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/rtc_battery_identify xyz.openbmc_project.Led.Group Asserted b false
SENSOR:
3) pldmtool platform GetPDR -d 126 { "nextRecordHandle": 127, "responseCount": 27, "recordHandle": 126, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 47, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/rtc_battery_identify xyz.openbmc_project.Led.Group Asserted b true
pldmtool raw --data 0x80 0x02 0x21 0x2F 0x00 0x01 0x00 Request Message: 08 01 80 02 21 2f 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
Set Off: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/rtc_battery_identify xyz.openbmc_project.Led.Group Asserted b false
pldmtool raw --data 0x80 0x02 0x21 0x2F 0x00 0x01 0x00 Request Message: 08 01 80 02 21 2f 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
Signed-off-by: Jayashankar Padath <jayashankar.padath@in.ibm.com> Change-Id: I9f0f226847e880bbdeccc4f77f89a8f3da04e070
show more ...
|
#
df2fa47b |
| 04-May-2021 |
Jayashankar Padath <jayashankar.padath@in.ibm.com> |
pdr: Sensor/Effecter support for fan fault leds
This is to support sensor/effecter pdrs for fan fault leds.
Testing Result: Note: sensor/effecter ids may change in the testing result as testing was
pdr: Sensor/Effecter support for fan fault leds
This is to support sensor/effecter pdrs for fan fault leds.
Testing Result: Note: sensor/effecter ids may change in the testing result as testing was done with reduced pdrs for simplicity. Also test result only mentioned below for corner scenarios that is for fan0 and fan5.
SENSORS:
pldmtool platform GetPDR -d 25 (fan0) { "nextRecordHandle": 26, "responseCount": 27, "recordHandle": 25, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 6, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
fsn 0 Set On: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/fan0_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool raw --data 0x80 0x02 0x21 0x06 0x00 0x01 0x00 Request Message: 08 01 80 02 21 06 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
fan0 Set Off: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/fan0_fault xyz.openbmc_project.Led.Group Asserted b false
pldmtool raw --data 0x80 0x02 0x21 0x06 0x00 0x01 0x00 Request Message: 08 01 80 02 21 06 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
pldmtool platform GetPDR -d 30 (fan5) { "nextRecordHandle": 31, "responseCount": 27, "recordHandle": 30, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 11, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
fan 5 Set On: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/fan5_fault xyz.openbmc_project.Led.Group Asserted b true
pldmtool raw --data 0x80 0x02 0x21 0x0B 0x00 0x01 0x00 Request Message: 08 01 80 02 21 0b 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
fan5 Set Off: busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/fan5_fault xyz.openbmc_project.Led.Group Asserted b false
pldmtool raw --data 0x80 0x02 0x21 0x0B 0x00 0x01 0x00 Request Message: 08 01 80 02 21 0b 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
EFFECTER:
pldmtool platform GetPDR -d 34 (fan0) { "nextRecordHandle": 35, "responseCount": 29, "recordHandle": 34, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 4, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
fan0 Set On: pldmtool raw -d 0x80 0x02 0x39 0x04 0x00 0x01 0x01 0x01 Request Message: 08 01 80 02 39 04 00 01 01 01 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/fan0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b true
fan0 Set Off: pldmtool raw -d 0x80 0x02 0x39 0x04 0x00 0x01 0x01 0x02 Request Message: 08 01 80 02 39 04 00 01 01 02 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/fan0 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b false
pldmtool platform GetPDR -d 39 (fan5) { "nextRecordHandle": 40, "responseCount": 29, "recordHandle": 39, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 9, "entityType": "0(OEM)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
fan5 Set Off: pldmtool raw -d 0x80 0x02 0x39 0x09 0x00 0x01 0x01 0x02 Request Message: 08 01 80 02 39 09 00 01 01 02 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/fan5 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b false
fan5 Set On: pldmtool raw -d 0x80 0x02 0x39 0x09 0x00 0x01 0x01 0x01 Request Message: 08 01 80 02 39 09 00 01 01 01 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/fan5 xyz.openbmc_project.State.Decorator.OperationalStatus Functional b true
Signed-off-by: Jayashankar Padath <jayashankar.padath@in.ibm.com> Change-Id: Id92230f55d788b008a80701a6108e41981b95aea
show more ...
|
#
50304da5 |
| 14-Apr-2021 |
Jayashankar Padath <jayashankar.padath@in.ibm.com> |
pdr: Sensor/Effecter support for enc fault and identify leds
This is to support sensor/effecter pdrs for enclosure fault led and enclosure identify led.
Testing Result:
EFFECTER:
Enclosure Identi
pdr: Sensor/Effecter support for enc fault and identify leds
This is to support sensor/effecter pdrs for enclosure fault led and enclosure identify led.
Testing Result:
EFFECTER:
Enclosure Identify Use Cases:
pldmtool platform GetPDR -d 55 { "nextRecordHandle": 56, "responseCount": 29, "recordHandle": 55, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 2, "entityType": "System chassis (main enclosure)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: pldmtool raw -d 0x80 0x02 0x39 0x02 0x00 0x01 0x01 0x01 Request Message: 08 01 80 02 39 02 00 01 01 01 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/enclosure_identify xyz.openbmc_project.Led.Group Asserted b true
Set Off: pldmtool raw -d 0x80 0x02 0x39 0x02 0x00 0x01 0x01 0x02 Request Message: 08 01 80 02 39 02 00 01 01 02 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/enclosure_identify xyz.openbmc_project.Led.Group Asserted b false
Enclosure Fault Use Cases:
pldmtool platform GetPDR -d 56 { "nextRecordHandle": 57, "responseCount": 29, "recordHandle": 56, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 3, "entityType": "System chassis (main enclosure)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set state as On: pldmtool raw -d 0x80 0x02 0x39 0x03 0x00 0x01 0x01 0x01 Request Message: 08 01 80 02 39 03 00 01 01 01 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/enclosure_fault xyz.openbmc_project.Led.Group Asserted b true
Set state as Off: pldmtool raw -d 0x80 0x02 0x39 0x03 0x00 0x01 0x01 0x02 Request Message: 08 01 80 02 39 03 00 01 01 02 Response Message: 08 01 00 02 39 00
busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/enclosure_fault xyz.openbmc_project.Led.Group Asserted b false
SENSOR:
Enc Identify Use Cases:
pldmtool platform GetPDR -d 24 { "nextRecordHandle": 25, "responseCount": 27, "recordHandle": 24, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 3, "entityType": "System chassis (main enclosure)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "17", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: busctl set-property xyz.openbmc_project.LED.Controller.virtual_enc_id /xyz/openbmc_project/led/physical/virtual_enc_id xyz.openbmc_project.Led.Physical State s "xyz.openbmc_project.Led.Physical.Action.On" pldmtool raw --data 0x80 0x02 0x21 0x03 0x00 0x01 0x00 Request Message: 08 01 80 02 21 03 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
Set Off: busctl set-property xyz.openbmc_project.LED.Controller.virtual_enc_id /xyz/openbmc_project/led/physical/virtual_enc_id xyz.openbmc_project.Led.Physical State s "xyz.openbmc_project.Led.Physical.Action.Off"
pldmtool raw --data 0x80 0x02 0x21 0x03 0x00 0x01 0x00 Request Message: 08 01 80 02 21 03 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
Enc Fault Use Cases:
pldmtool platform GetPDR -d 25 { "nextRecordHandle": 26, "responseCount": 27, "recordHandle": 25, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 17, "PLDMTerminusHandle": 0, "sensorID": 4, "entityType": "System chassis (main enclosure)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 1, "stateSetID[0]": "10", "possibleStatesSize[0]": 1, "possibleStates[0]": " 1 2" }
Set On: busctl set-property xyz.openbmc_project.LED.Controller.virtual_enc_fault /xyz/openbmc_project/led/physical/virtual_enc_fault xyz.openbmc_project.Led.Physical State s "xyz.openbmc_project.Led.Physical.Action.On" pldmtool raw --data 0x80 0x02 0x21 0x04 0x00 0x01 0x00 Request Message: 08 01 80 02 21 04 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 01
Set Off: busctl set-property xyz.openbmc_project.LED.Controller.virtual_enc_fault /xyz/openbmc_project/led/physical/virtual_enc_fault xyz.openbmc_project.Led.Physical State s "xyz.openbmc_project.Led.Physical.Action.Off" pldmtool raw --data 0x80 0x02 0x21 0x04 0x00 0x01 0x00 Request Message: 08 01 80 02 21 04 00 01 00 Response Message: 08 01 00 02 21 00 01 00 01 00 02
Signed-off-by: Jayashankar Padath <jayashankar.padath@in.ibm.com> Change-Id: Id9ae0ce5bba1c1a63d3de20daa22571d24a8d9f2
show more ...
|
#
06f34416 |
| 01-Mar-2021 |
Varsha Kaverappa <vkaverap@in.ibm.com> |
PDR/Sensor/Effecter for BMC owned LEDs
PDR: root@witherspoon-tacoma-YA30UF043011:/usr/bin# ./pldmtool platform GetPDR -d 9 { "nextRecordHandle": 10, "responseCount": 29, "recordHandle":
PDR/Sensor/Effecter for BMC owned LEDs
PDR: root@witherspoon-tacoma-YA30UF043011:/usr/bin# ./pldmtool platform GetPDR -d 9 { "nextRecordHandle": 10, "responseCount": 29, "recordHandle": 9, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 2, "entityType": "19(OEM)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID": "17", "possibleStatesSize": 1, "possibleStates": " 1 1 2" } root@witherspoon-tacoma-YA30UF043011:/usr/bin# ./pldmtool platform GetPDR -d 10 { "nextRecordHandle": 11, "responseCount": 29, "recordHandle": 10, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 19, "PLDMTerminusHandle": 1, "effecterID": 3, "entityType": "19(OEM)", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID": "10", "possibleStatesSize": 1, "possibleStates": " 1 1 2" }
root@w80:~# pldmtool platform GetPDR -d 14 { "nextRecordHandle": 15, "responseCount": 23, "recordHandle": 14, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 13, "PLDMTerminusHandle": 0, "sensorID": 1, "entityType": "19(OEM)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 0 } root@w80:~# pldmtool platform GetPDR -d 15 { "nextRecordHandle": 0, "responseCount": 23, "recordHandle": 15, "PDRHeaderVersion": 1, "PDRType": "State Sensor PDR", "recordChangeNumber": 0, "dataLength": 13, "PLDMTerminusHandle": 0, "sensorID": 2, "entityType": "19(OEM)", "entityInstanceNumber": 0, "containerID": 0, "sensorInit": "noInit", "sensorAuxiliaryNamesPDR": false, "compositeSensorCount": 0 }
Write Effecter test: root@w56:~# busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/base_blyth_identify xyz.openbmc_project.Led.Group Asserted b false root@w56:~# pldmtool platform SetStateEffecterStates -i 2 -c 1 -d 1 1 --verbose Request Message: 08 01 80 02 39 02 00 01 01 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Success in creating the socket : RC = 4 Success in connecting to socket : RC = 0 Success in sending message type as pldm to mctp : RC = 0 Write to socket successful : RC = 24 Total length:6 Shutdown Socket successful : RC = 0 Response Message: 08 01 00 02 39 00 { "Response": "SUCCESS" } root@w56:~# busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/base_blyth_identify xyz.openbmc_project.Led.Group Asserted b true
Sensor Read root@rain104bmc:~# busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/base_blyth_identify xyz.openbmc_project.Led.Group Asserted b false root@rain104bmc:~# pldmtool raw --data 0x80 0x02 0x21 0x01 0x00 0x01 0x00 Request Message: 08 01 80 02 21 01 00 01 00 Response Message: 08 01 00 02 21 00 01 00 00 00 02 root@rain104bmc:~# busctl set-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/base_blyth_identify xyz.openbmc_project.Led.Group Asserted b true root@rain104bmc:~# busctl get-property xyz.openbmc_project.LED.GroupManager /xyz/openbmc_project/led/groups/base_blyth_identify xyz.openbmc_project.Led.Group Asserted b true root@rain104bmc:~# pldmtool raw --data 0x80 0x02 0x21 0x01 0x00 0x01 0x00 Request Message: 08 01 80 02 21 01 00 01 00 Response Message: 08 01 00 02 21 00 01 00 00 00 01
Signed-off-by: Varsha Kaverappa <vkaverap@in.ibm.com> Change-Id: Idbe765eeeaf229838f721918da01a15d5391cab2
show more ...
|
#
ada39c0f |
| 10-Mar-2021 |
Pavithra Barithaya <pavithra.b@ibm.com> |
PLDM: Remove Boot Progress entry from 11.json
Phyp is using a sensor to communicate the boot progress state changes to pldm.This commit verifies that and removes the Boot Progress entry from 11.json
PLDM: Remove Boot Progress entry from 11.json
Phyp is using a sensor to communicate the boot progress state changes to pldm.This commit verifies that and removes the Boot Progress entry from 11.json which was used earlier.
Change-Id: I43a385a5a1c30f522bdaa848d44d67ef97d5d20f Signed-off-by: Pavithra Barithaya <pavithra.b@ibm.com>
show more ...
|
#
2114a6c5 |
| 06-Mar-2021 |
Manojkiran Eda <manojkiran.eda@gmail.com> |
Fix the dbus object path for bmc effecter
- This commit would fix the object path of the bmc effecter that sets the ScheduledTime dbus property.
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmai
Fix the dbus object path for bmc effecter
- This commit would fix the object path of the bmc effecter that sets the ScheduledTime dbus property.
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmail.com> Change-Id: Iee307889081691a1ee8fe2fe950b5bb40e30b484
show more ...
|
#
e7e46f58 |
| 13-Jan-2021 |
Manojkiran Eda <manojkiran.eda@gmail.com> |
Update State Effecter PDR to support BMC Reboot
- This commit would enable the state effecter PDR on BMC to support BMC Reboot.
Tested By:
# pldmtool platform getpdr -d 25 { "nextRecordHandl
Update State Effecter PDR to support BMC Reboot
- This commit would enable the state effecter PDR on BMC to support BMC Reboot.
Tested By:
# pldmtool platform getpdr -d 25 { "nextRecordHandle": 26, "responseCount": 30, "recordHandle": 25, "PDRHeaderVersion": 1, "PDRType": "State Effecter PDR", "recordChangeNumber": 0, "dataLength": 20, "PLDMTerminusHandle": 1, "effecterID": 4, "entityType": "Management Controller", "entityInstanceNumber": 0, "containerID": 0, "effecterSemanticID": 0, "effecterInit": "noInit", "effecterDescriptionPDR": false, "compositeEffecterCount": 1, "stateSetID[0]": "Availability(2)", "possibleStatesSize[0]": 2, "possibleStates[0]": " 8" }
# pldmtool platform SetStateEffecterStates -v -i 4 -c 1 -d 1 8 Request Message: 08 01 80 02 39 04 00 01 01 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Success in creating the socket : RC = 4 Success in connecting to socket : RC = 0 Success in sending message type as pldm to mctp : RC = 0 Write to socket successful : RC = 24 Total length:6 Shutdown Socket successful : RC = 0 Response Message: 08 01 00 02 39 00 { "Response": "SUCCESS" }
Post receiving SUCCESS, the BMC was rebooted.
Signed-off-by: Manojkiran Eda <manojkiran.eda@gmail.com> Change-Id: I6cf802813af84351ec2a59a26e8032b7169d759d
show more ...
|
#
7af135df |
| 20-Nov-2020 |
Tom Joseph <tomjoseph@in.ibm.com> |
BootProgress: Update the boot progress effecter
Tested:
PDR information:
PLDMTerminusHandle: 1 effecterID: 1 entityType: Virtual Machine Manager entityInstanceNumber: 0 containerID: 0 effecterSema
BootProgress: Update the boot progress effecter
Tested:
PDR information:
PLDMTerminusHandle: 1 effecterID: 1 entityType: Virtual Machine Manager entityInstanceNumber: 0 containerID: 0 effecterSemanticID: 0 effecterInit: noInit effecterDescriptionPDR: false compositeEffecterCount: 1 stateSetID: Boot Progress(196) possibleStatesSize: 4 possibleStates: 1 2 3 5 9 21 22 26
root@rainier:~# obmcutil state CurrentBMCState : xyz.openbmc_project.State.BMC.BMCState.Ready CurrentPowerState : xyz.openbmc_project.State.Chassis.PowerState.On CurrentHostState : xyz.openbmc_project.State.Host.HostState.Quiesced BootProgress : xyz.openbmc_project.State.Boot.Progress.ProgressStages.PCIInit OperatingSystemState: xyz.openbmc_project.State.OperatingSystem.Status.OSStatus.Inactive
Signed-off-by: Tom Joseph <tomjoseph@in.ibm.com> Change-Id: Ib3ed8dc6ed54f30eeba0a9bee9fc314e5fa6149a
show more ...
|