meta-facebook: yosemite4: NIC[0~3] power fault event log
Summary: The system shall register an event when NIC[0~3] power fault. BMC monitors GPIO "ALT_SMB_BMC_CPLD2_N" and then read IOE pin.
Test P
meta-facebook: yosemite4: NIC[0~3] power fault event log
Summary: The system shall register an event when NIC[0~3] power fault. BMC monitors GPIO "ALT_SMB_BMC_CPLD2_N" and then read IOE pin.
Test Plan: With a testing CPLD firmware, set IOE pin high to trigger NIC power fault.
Testing: 1. trigger NIC1 power fault by setting IOE reg 0x0a, bit1 = 1: root@bmc:~# i2ctransfer -f -y 28 w2@0x25 0x0a 0x02 r1 0x00
2. read IOE reg 0x01 (bit1 = 1): root@bmc:~# i2ctransfer -f -y 28 w1@0x25 0x01 r1 0x02
3. Check event log root@bmc:~# mfg-tool log-display "2": { "additional_data": [ "NIC1 Power Fault=1" ], "event_id": "", "message": "NIC1 Power Fault", "resolution": "", "resolved": false, "severity": "xyz.openbmc_project.Logging.Entry.Level.Error", "timestamp": "2024-08-19T07:50:01.311000000Z", "updated_timestamp": "2024-08-19T07:50:01.311000000Z" },
Change-Id: I12b297b14b8be4c97c1f7d0949b0b6c16b91fa40 Signed-off-by: Rush Chen <rush.chen.wiwynn@gmail.com>