912170e6 |
| 29-Jul-2024 |
Patrick Rudolph <patrick.rudolph@9elements.com> |
configurations/sbp1: Update P12V thresholds
Allow a bigger margin on the PMBus compatible regualtors for the P12V rail and update all input voltage sensors reporting this voltage. Using 10.8V as low
configurations/sbp1: Update P12V thresholds
Allow a bigger margin on the PMBus compatible regualtors for the P12V rail and update all input voltage sensors reporting this voltage. Using 10.8V as lower critical and 11.4V as lower non critical.
Update the ADC sensor to use 11.0V and 11.5V as lower limits.
Change-Id: I04af47a2c067ccdf895d8b20310719e238e34e63 Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
show more ...
|
#
d0fd3b1f |
| 17-Nov-2023 |
Patrick Rudolph <patrick.rudolph@9elements.com> |
configurations: sbp1: Add Hysteresis
dbus-sensors uses a default threshold hysteresis of 2.55 V/A/°C, which is too much for most sensors found on SBP1. In order to reset the critical/warning thresho
configurations: sbp1: Add Hysteresis
dbus-sensors uses a default threshold hysteresis of 2.55 V/A/°C, which is too much for most sensors found on SBP1. In order to reset the critical/warning threshold the sensor value has to go out of the acceptable range in the opposite direction. Adjust the hysteresis to 1% of the threshold value.
Tested: Warning/Critical thresholds reset earlier when the value is back to normal.
Change-Id: Ife33b456e930d2d8df61df9da8bcebb1a5f4d577 Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
show more ...
|
#
2e61474d |
| 10-Nov-2023 |
Patrick Rudolph <patrick.rudolph@9elements.com> |
configurations: sbp1: Add rulerdrive efuses
SBP1 has 32 slots for rulerdrive SSDs. Every slot has it's own MAX5970 eFuse that provides voltage and current sensor readings.
While the MAX5970 is on t
configurations: sbp1: Add rulerdrive efuses
SBP1 has 32 slots for rulerdrive SSDs. Every slot has it's own MAX5970 eFuse that provides voltage and current sensor readings.
While the MAX5970 is on the baseboard it only makes sense to show the sensor values when a rulerdrive is plugged into the corresponding slot. Thus add the MAX5970 as separate chassis object with the probe condition to evaluate if the slot is occupied.
Change-Id: I870175a2098f0acc41b806928cf3f40b9f0f86f3 Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
show more ...
|