Home
last modified time | relevance | path

Searched refs:air (Results 1 – 25 of 70) sorted by relevance

123

/openbmc/openbmc/meta-ibm/recipes-phosphor/dbus/
H A Dfan-policy.bb11 SRC_URI:append:df-openpower = " file://air-cooled.yaml"
15 SRC_URI:remove:p10bmc = "file://air-cooled.yaml"
19 install -D ${WORKDIR}/air-cooled.yaml ${D}${config_dir}/air-cooled.yaml
25 FILES:${PN} += "${config_dir}/air-cooled.yaml"
29 FILES:${PN}:remove:p10bmc = "${config_dir}/air-cooled.yaml"
/openbmc/phosphor-dbus-interfaces/yaml/xyz/openbmc_project/Inventory/Decorator/
H A DThermalDirection.interface.yaml20 A chassis with the air intake in the back and exhaust out the
24 A chassis with the air intake in the front and exhaust out the
28 A sealed chassis with no air pathway.
31 A chassis with air exhaust on the top.
H A DCoolingType.interface.yaml2 Implement properties to indicate the element cooling type (air, water,
8 The element uses air/fans for cooling when set to true.
/openbmc/phosphor-fan-presence/cooling-type/
H A Dmain.cpp22 bool air = false; in main() local
30 app.add_flag("-a,--air", air, in main()
59 if (air) in main()
/openbmc/linux/Documentation/devicetree/bindings/iio/chemical/
H A Dsensirion,sps30.yaml34 air-pollution-sensor@69 {
41 air-pollution-sensor {
H A Dplantower,pms7003.yaml7 title: Plantower PMS7003 air pollution sensor
46 air-pollution-sensor {
/openbmc/phosphor-fan-presence/control/example/
H A Dzones.yaml15 #example, a fan may only be in zone 0 if it's the air cooled version
17 #case, the fan yaml would have a cooling_profile of 'air' to match
54 # - air
H A Dfans.yaml33 # cooling_profile: air
/openbmc/openbmc/meta-ibm/recipes-phosphor/dbus/fan-policy/swift/
H A Dair-cooled.yaml3 # An air cooled Swift requires a minimum of three functional fan enclosures.
9 'An air cooled Swift has four fan enclosures to monitor.'
73 - name: chassis air cooled
117 properties: chassis air cooled
121 'If this condition passes the chassis is air cooled.'
125 properties: chassis air cooled
/openbmc/dbus-sensors/
H A Dmeson.options3 option('exit-air', type: 'feature', value: 'enabled', description: 'Enable exit air sensor.',)
/openbmc/openbmc/meta-ibm/recipes-phosphor/dbus/fan-policy/witherspoon/
H A Dair-cooled.yaml3 # An air cooled Witherspoon requires a minimum of three functional fans
11 'An air cooled Witherspoon has four fan enclosures to monitor.'
26 'An air cooled Witherspoon has eight fan rotors to monitor.'
98 - name: chassis air cooled
151 properties: chassis air cooled
155 'If this condition passes the chassis is air cooled.'
159 properties: chassis air cooled
/openbmc/linux/arch/arm64/boot/dts/amlogic/
H A DMakefile69 dtb-$(CONFIG_ARCH_MESON) += meson-sm1-a95xf3-air-gbit.dtb
70 dtb-$(CONFIG_ARCH_MESON) += meson-sm1-a95xf3-air.dtb
78 dtb-$(CONFIG_ARCH_MESON) += meson-sm1-x96-air-gbit.dtb
79 dtb-$(CONFIG_ARCH_MESON) += meson-sm1-x96-air.dtb
H A Dmeson-sm1-a95xf3-air.dts13 compatible = "cyx,a95xf3-air", "amlogic,sm1";
/openbmc/dbus-sensors/src/
H A Dmeson.build80 if get_option('exit-air').allowed()
81 subdir('exit-air')
/openbmc/linux/Documentation/devicetree/bindings/arm/
H A Damlogic.yaml189 - amediatech,x96-air
190 - amediatech,x96-air-gbit
193 - cyx,a95xf3-air
194 - cyx,a95xf3-air-gbit
/openbmc/linux/Documentation/translations/zh_CN/rust/
H A Dcoding-guidelines.rst120 /// let x = Some("air");
121 /// assert_eq!(unsafe { x.unwrap_unchecked() }, "air");
/openbmc/openbmc/meta-phosphor/recipes-phosphor/sensors/
H A Ddbus-sensors_git.bb29 PACKAGECONFIG[exitairtempsensor] = "-Dexit-air=enabled, -Dexit-air=disabled"
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-fan-config/swift/
H A Dfans.yaml14 cooling_profile: air
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-fan-config/witherspoon/
H A Dfans.yaml14 cooling_profile: air
/openbmc/u-boot/configs/
H A Dnanopi_neo_air_defconfig15 CONFIG_DEFAULT_DEVICE_TREE="sun8i-h3-nanopi-neo-air"
/openbmc/openbmc-test-automation/ipmi/
H A Dtest_ipmi_sensor.robot50 # Inlet air temperature(40h) 1 +22 C
51 # Inlet air temperature(40h) 2 +23 C
52 # Inlet air temperature(40h) 3 +22 C
58 Should Contain ${temp_reading} Inlet air temperature
63 ... Inlet air temperature case-insensitive
113 # Inlet air temperature(40h) 1 +22 C
114 # Inlet air temperature(40h) 2 +23 C
115 # Inlet air temperature(40h) 3 +22 C
/openbmc/openbmc/meta-openembedded/meta-multimedia/recipes-multimedia/dvb-apps/files/dvb-scan-table/dvb-t/
H A Dlu-All14 [Kanal 21 air]
/openbmc/dbus-sensors/service_files/
H A Dmeson.build10 ['exit-air', 'xyz.openbmc_project.exitairsensor.service'],
/openbmc/openbmc/meta-ibm/recipes-phosphor/fans/phosphor-fan-control-zone-config/swift/
H A Dzones.yaml13 - air
/openbmc/phosphor-fan-presence/monitor/example/
H A Dmonitor.yaml83 # # Only create fan functional properties and monitor on air cooled
110 # # Only create fan functional properties and monitor on air cooled

123