/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema/ |
H A D | FabricAdapter.v1_5_3.json | 36 …"description": "A fabric adapter represents the physical fabric adapter capable of connecting to a… 37 …"longDescription": "This resource shall represent a physical fabric adapter capable of connecting … 66 "description": "The manufacturer name for the ASIC of this fabric adapter.", 67 … property shall contain the manufacturer name of the ASIC for the fabric adapter as defined by the… 75 "description": "The part number for the ASIC on this fabric adapter.", 76 … "This property shall contain the part number of the ASIC for the fabric adapter as defined by the… 84 "description": "The revision identifier for the ASIC on this fabric adapter.", 85 …roperty shall contain the revision identifier of the ASIC for the fabric adapter as defined by the… 110 "description": "The configured fabric type of this fabric adapter.", 111 …longDescription": "This property shall contain the configured fabric type of this fabric adapter.", [all …]
|
H A D | NetworkAdapter.v1_12_1.json | 201 "description": "A network controller ASIC that makes up part of a network adapter.", 202 …on": "This type shall describe a network controller ASIC that makes up part of a network adapter.", 233 "description": "The durable names for the network adapter controller.", 237 …contain a list of all known durable names for the controller associated with the network adapter.", 248 "description": "The location of the network adapter controller.", 249 …rty shall contain the location information of the controller associated with the network adapter.", 334 …"description": "The `NetworkAdapter` schema represents a physical network adapter capable of conne… 335 …"longDescription": "This resource shall represent a physical network adapter capable of connecting… 370 … "description": "The link to the assembly resource associated with this adapter.", 387 …is property shall contain the set of network controllers ASICs that make up this network adapter.", [all …]
|
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema-installed/ |
H A D | FabricAdapter.v1_5_3.json | 36 …"description": "A fabric adapter represents the physical fabric adapter capable of connecting to a… 37 …"longDescription": "This resource shall represent a physical fabric adapter capable of connecting … 66 "description": "The manufacturer name for the ASIC of this fabric adapter.", 67 … property shall contain the manufacturer name of the ASIC for the fabric adapter as defined by the… 75 "description": "The part number for the ASIC on this fabric adapter.", 76 … "This property shall contain the part number of the ASIC for the fabric adapter as defined by the… 84 "description": "The revision identifier for the ASIC on this fabric adapter.", 85 …roperty shall contain the revision identifier of the ASIC for the fabric adapter as defined by the… 110 "description": "The configured fabric type of this fabric adapter.", 111 …longDescription": "This property shall contain the configured fabric type of this fabric adapter.", [all …]
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Rainier1S4U/ |
H A D | pcie_cards.json | 52 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 1.6TB", 60 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 3.2TB", 68 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 6.4TB", 76 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 1.6TB", 84 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 3.2TB", 92 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 6.4TB", 148 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 1.6TB", 156 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 3.2TB", 164 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 6.4TB", 204 "name": "Shale 4 port ROCE adapter", [all …]
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Rainier4U/ |
H A D | pcie_cards.json | 68 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 1.6TB", 76 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 3.2TB", 84 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 6.4TB", 92 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 1.6TB", 100 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 3.2TB", 108 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 6.4TB", 164 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 1.6TB", 172 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 3.2TB", 180 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 6.4TB", 220 "name": "Shale 4 port ROCE adapter", [all …]
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.BlueRidge1S4U/ |
H A D | pcie_cards.json | 52 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 1.6TB", 60 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 3.2TB", 68 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 6.4TB", 76 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 1.6TB", 84 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 3.2TB", 92 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 6.4TB", 148 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 1.6TB", 156 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 3.2TB", 164 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 6.4TB", 204 "name": "Shale 4 port ROCE adapter", [all …]
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Rainier2U/ |
H A D | pcie_cards.json | 68 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 1.6TB", 76 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 3.2TB", 84 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 6.4TB", 92 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 1.6TB", 100 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 3.2TB", 108 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 6.4TB", 116 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 1.6TB", 124 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 3.2TB", 132 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 6.4TB", 196 "name": "Moso PCIe4 64Gb 2-port Fibre Channel Adapter",
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.BlueRidge4U/ |
H A D | pcie_cards.json | 68 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 1.6TB", 76 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 3.2TB", 84 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 6.4TB", 92 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 1.6TB", 100 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 3.2TB", 108 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 6.4TB", 164 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 1.6TB", 172 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 3.2TB", 180 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 6.4TB", 220 "name": "Shale 4 port ROCE adapter", [all …]
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.BlueRidge2U/ |
H A D | pcie_cards.json | 68 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 1.6TB", 76 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 3.2TB", 84 "name": "Bolt PCIe3 NVMe Flash Adapter II x8 6.4TB", 92 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 1.6TB", 100 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 3.2TB", 108 "name": "Bolt PCIe3 NVMe Flash Adapter III x8 6.4TB", 116 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 1.6TB", 124 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 3.2TB", 132 "name": "Kona PCIe4 NVMe U.2 Flash Adapter x8 6.4TB", 196 "name": "Moso PCIe4 64Gb 2-port Fibre Channel Adapter",
|
/openbmc/bmcweb/redfish-core/schema/dmtf/csdl/ |
H A D | FabricAdapter_v1.xml | 62 …Annotation Term="OData.Description" String="A fabric adapter represents the physical fabric adapte… 63 …LongDescription" String="This resource shall represent a physical fabric adapter capable of connec… 101 …OData.Description" String="The link to the collection of ports that exist on the fabric adapter."/> 107 … <Annotation Term="OData.Description" String="The manufacturer or OEM of this fabric adapter."/> 108 …ing="This property shall contain a value that represents the manufacturer of the fabric adapter."/> 112 <Annotation Term="OData.Description" String="The model string for this fabric adapter."/> 113 …property shall contain the information about how the manufacturer refers to this fabric adapter."/> 117 … <Annotation Term="OData.Description" String="The manufacturer SKU for this fabric adapter."/> 118 …Term="OData.LongDescription" String="This property shall contain the SKU for the fabric adapter."/> 122 <Annotation Term="OData.Description" String="The serial number for this fabric adapter."/> [all …]
|
/openbmc/bmcweb/redfish-core/schema/dmtf/installed/ |
H A D | FabricAdapter_v1.xml | 62 …Annotation Term="OData.Description" String="A fabric adapter represents the physical fabric adapte… 63 …LongDescription" String="This resource shall represent a physical fabric adapter capable of connec… 101 …OData.Description" String="The link to the collection of ports that exist on the fabric adapter."/> 107 … <Annotation Term="OData.Description" String="The manufacturer or OEM of this fabric adapter."/> 108 …ing="This property shall contain a value that represents the manufacturer of the fabric adapter."/> 112 <Annotation Term="OData.Description" String="The model string for this fabric adapter."/> 113 …property shall contain the information about how the manufacturer refers to this fabric adapter."/> 117 … <Annotation Term="OData.Description" String="The manufacturer SKU for this fabric adapter."/> 118 …Term="OData.LongDescription" String="This property shall contain the SKU for the fabric adapter."/> 122 <Annotation Term="OData.Description" String="The serial number for this fabric adapter."/> [all …]
|
/openbmc/openbmc/meta-openembedded/meta-networking/recipes-connectivity/openthread/wpantund/ |
H A D | basename.patch | 10 --- a/third_party/openthread/tools/spi-hdlc-adapter/spi-hdlc-adapter.c 11 +++ b/third_party/openthread/tools/spi-hdlc-adapter/spi-hdlc-adapter.c
|
/openbmc/qemu/tests/qemu-iotests/ |
H A D | 237.out | 37 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "ide", "… 64 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "buslogi… 92 === Adapter types === 94 == Valid adapter types == 96 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "ide", "… 101 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "buslogi… 106 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "lsilogi… 111 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "legacyE… 116 == Invalid adapter types == 118 {"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"adapter-type": "foo", "… [all …]
|
H A D | 237 | 81 'adapter-type': 'ide', 110 'adapter-type': 'buslogic', 129 # Adapter types 132 iotests.log("=== Adapter types ===") 138 iotests.log("== Valid adapter types ==") 146 'adapter-type': adapter_type }) 150 iotests.log("== Invalid adapter types ==") 158 'adapter-type': adapter_type })
|
/openbmc/u-boot/doc/ |
H A D | README.usb | 64 CONFIG_USB_HOST_ETHER enables USB ethernet adapter support 70 If you have a supported USB Ethernet adapter you can use it in U-Boot 74 client. In that case your board is pretending to be an Ethernet adapter 79 Ethernet adapter to which it is directly connected and the connection to 80 the outside world is your adapter's Ethernet cable. Your board becomes an 99 supported device list, so we know this adapter is supported. 103 If your adapter is not listed there is a still a chance that it will 104 work. Try looking up the manufacturer of the chip inside your adapter. 105 or take the adapter apart and look for chip markings. Then add a line 108 between the chip in your adapter and the driver. You could try to get a [all …]
|
H A D | README.fsl-esdhc | 4 Support Freescale adapter card type identification. This is implemented by 6 Card ID[0:2] bits showing the type of card installed in the SDHC Adapter Slot. 8 SDHC Card ID[0:2] Adapter Card Type
|
/openbmc/bmcweb/redfish-core/include/registries/ |
H A D | network_device_message_registry.hpp | 46 "A network cable was inserted into network adapter '%1' port '%2'.", 59 "A cable was removed from network adapter '%1' port '%2'.", 72 "The connection is no longer active for network adapter '%1' port '%2' function '%3'.", 86 … "A network connection was established for network adapter '%1' port '%2' function '%3'.", 100 … "A degraded network connection was established for network adapter '%1' port '%2' function '%3'.", 114 …"The network connection for network adapter '%1' port '%2' function '%3' was established and dropp…
|
/openbmc/qemu/hw/intc/ |
H A D | s390_flic_kvm.c | 21 #include "hw/s390x/adapter.h" 279 struct kvm_s390_io_adapter adapter = { in kvm_s390_register_io_adapter() local 290 .addr = (uint64_t)&adapter, in kvm_s390_register_io_adapter() 327 static int kvm_irqchip_add_adapter_route(KVMState *s, AdapterInfo *adapter) in kvm_irqchip_add_adapter_route() argument 344 kroute.u.adapter.summary_addr = adapter->summary_addr; in kvm_irqchip_add_adapter_route() 345 kroute.u.adapter.ind_addr = adapter->ind_addr; in kvm_irqchip_add_adapter_route() 346 kroute.u.adapter.summary_offset = adapter->summary_offset; in kvm_irqchip_add_adapter_route() 347 kroute.u.adapter.ind_offset = adapter->ind_offset; in kvm_irqchip_add_adapter_route() 348 kroute.u.adapter.adapter_id = adapter->adapter_id; in kvm_irqchip_add_adapter_route() 359 uint64_t ind_offset = routes->adapter.ind_offset; in kvm_s390_add_adapter_routes() [all …]
|
/openbmc/phosphor-power/tools/i2c/ |
H A D | i2c.hpp | 39 /** @brief Empty adapter functionality value with no bit flags set */ 54 /** @brief Cached I2C adapter functionality value */ 80 /** @brief Get I2C adapter functionality 82 * Caches the adapter functionality value since it shouldn't change after 86 * @return Adapter functionality value 90 /** @brief Check i2c adapter read functionality 92 * Check if the i2c adapter has the functionality specified by the SMBus 101 /** @brief Check i2c adapter write functionality 103 * Check if the i2c adapter has the functionality specified by the SMBus
|
/openbmc/pldm/oem/ibm/libpldmresponder/ |
H A D | collect_slot_vpd.hpp | 102 /** @brief Method to obtain the Adapter dbus Object Path from Slot Adapter 105 * @return - if Successfull, returns the adapter dbus object path 111 * @param[in] adapterObjectPath - The adapter D-Bus object path 119 * @param[in] adapterObjectPath - The adapter D-Bus object path 138 * @param[in] adapterObjectPath - reference of the Adapter dbus object path 159 /** @brief pointer to tha matcher for Present State for adapter object*/
|
/openbmc/qemu/docs/system/s390x/ |
H A D | vfio-ap.rst | 10 of three AP instructions and from 1 to 256 PCIe cryptographic adapter cards. 14 On s390x, AP adapter cards are exposed via the AP bus. This document 24 * AP adapter 26 An AP adapter is an IBM Z adapter card that can perform cryptographic 29 running will be available to the linux host. Each adapter is identified by a 30 number from 0 to 255; however, the maximum adapter number allowed is 31 determined by machine model. When installed, an AP adapter is accessed by 36 An adapter is partitioned into domains. Each domain can be thought of as 37 a set of hardware registers for processing AP instructions. An adapter can 53 comprised of an AP adapter ID (APID) and an AP queue index (APQI). The [all …]
|
/openbmc/qemu/docs/specs/ |
H A D | pci-ids.rst | 27 SCSI host bus adapter device (legacy) 66 PCI serial port (16550A) adapter (:doc:`pci-serial`) 68 PCI Dual-port 16550A adapter (:doc:`pci-serial`) 70 PCI Quad-port 16550A adapter (:doc:`pci-serial`) 88 PCI xhci usb host adapter
|
/openbmc/phosphor-fan-presence/control/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Everest/ |
H A D | pcie_cards.json | 148 "name": "Moso PCIe4 64Gb 2-port Fibre Channel Adapter", 156 "name": "Dragonhead PCIe4 32Gb 4-port Fibre Channel Adapter", 164 "name": "Shale 4 port ROCE adapter", 172 "name": "Horton 32Gb 4-port Fibre Channel Adapter", 180 "name": "Nool 64Gb 2-port Fibre Channel Adapter",
|
/openbmc/u-boot/board/freescale/lx2160a/ |
H A D | lx2160a.c | 291 * Specifies the type of card installed in the SDHC1 adapter slot. in qixis_esdhc_detect_quirk() 293 * 001= eMMC V4.5 adapter is installed. in qixis_esdhc_detect_quirk() 294 * 010= SD/MMC 3.3V adapter is installed. in qixis_esdhc_detect_quirk() 295 * 011= eMMC V4.4 adapter is installed. in qixis_esdhc_detect_quirk() 296 * 100= eMMC V5.0 adapter is installed. in qixis_esdhc_detect_quirk() 297 * 101= MMC card/Legacy (3.3V) adapter is installed. in qixis_esdhc_detect_quirk() 298 * 110= SDCard V2/V3 adapter installed. in qixis_esdhc_detect_quirk() 299 * 111= no adapter is installed. in qixis_esdhc_detect_quirk() 341 /* - Routes {SDHC1_CMD, SDHC1_CLK } to SDHC1 adapter slot. in config_board_mux() 342 * {SDHC1_DAT3, SDHC1_DAT2} to SDHC1 adapter slot. in config_board_mux() [all …]
|
/openbmc/openbmc/meta-openembedded/meta-networking/recipes-connectivity/bluez-tools/bluez-tools/ |
H A D | fix-memory-leaks.patch | 36 - if (g_strstr_len(g_ascii_strdown(interface_name, -1), -1, "adapter")) 38 + if (strstr(interface_name_lowercase, "adapter")) 128 @@ -159,52 +159,39 @@ Adapter *find_adapter(const gchar *name, GError **error) 132 - // If name is null or empty - return default adapter 143 - // adapter = g_object_new(ADAPTER_TYPE, "DBusObjectPath", adapter_path, NULL); 144 - adapter = adapter_new(adapter_path); 146 + // adapter = g_object_new(ADAPTER_TYPE, "DBusObjectPath", adapter_path, NULL); 147 + adapter = adapter_new(adapter_path); 162 // adapter = g_object_new(ADAPTER_TYPE, "DBusObjectPath", adapter_path, NULL); 163 adapter = adapter_new(adapter_path); [all …]
|