51f0fd50 |
| 28-Dec-2021 |
Krzysztof Grobelny <krzysztof.grobelny@intel.com> |
Fixed issue with wrong timestamp
Telemetry service used steady_clock for generating timestamps, but it produced incorrect time. This change makes telemetry service use steady_clock for intervals and
Fixed issue with wrong timestamp
Telemetry service used steady_clock for generating timestamps, but it produced incorrect time. This change makes telemetry service use steady_clock for intervals and system_clock for timestamps.
Changed readings timestamp to display current timestamp instead of a time when reading was received.
Tested: - correct timestamp is visible on dbus - other telemetry service features are still working
Change-Id: Ic49f45640532cfffaeff5e0bd5591e6d99e5def5 Signed-off-by: Krzysztof Grobelny <krzysztof.grobelny@intel.com>
show more ...
|
#
8069771c |
| 04-Mar-2021 |
Krzysztof Grobelny <krzysztof.grobelny@intel.com> |
added support for Collection Functions
new supported operations: min,max,sum,avg new supported time scopes: interval,startup
added unit test to verify that each collection function returns correct
added support for Collection Functions
new supported operations: min,max,sum,avg new supported time scopes: interval,startup
added unit test to verify that each collection function returns correct timestamp and value
Tested: - POST/GET on telemetry features in bmcweb, no regression detected - Using dbus API metric with collection function works as expected
Change-Id: Ib364c433915e07fd7a102f00109525362c40ab8a Signed-off-by: Krzysztof Grobelny <krzysztof.grobelny@intel.com>
show more ...
|