c6fa1ddd | 06-Aug-2018 |
Adriana Kobylak <anoo@us.ibm.com> |
fan_control: Move to using xyz.openbmc_project.Sensors
The org.openbmc.Sensors interface has been replaced with xyz.openbmc_project.Sensors: https://github.com/openbmc/docs/blob/master/sensor-archit
fan_control: Move to using xyz.openbmc_project.Sensors
The org.openbmc.Sensors interface has been replaced with xyz.openbmc_project.Sensors: https://github.com/openbmc/docs/blob/master/sensor-architecture.md
Update the fan control app to use the supported sensor interface. This fan control provides two D-Bus methods that are not used by any current supported platform, but some platforms still include this app in their image so update it to serve as a reference. Also add an empty string as the second argument to the GetObject method call, otherwise the call fails to find the object.
Tested: Booted Romulus and verified the fan control app started.
Change-Id: I9e576e126a80863f47cab622d0029a389cddb644 Signed-off-by: Adriana Kobylak <anoo@us.ibm.com>