History log of /openbmc/pldm/oem/ampere/meson.build (Results 1 – 1 of 1)
Revision Date Author Comments
# a743e384 26-Oct-2024 Chau Ly <chaul@amperecomputing.com>

oem-ampere: eventManager: Handle `BootProgress` sensor event

Add Ampere OEM code to handle the `sensorEvent` for PLDM `BootProgress`
sensor. In Ampere system, the SOC termini will have the TID 1 or

oem-ampere: eventManager: Handle `BootProgress` sensor event

Add Ampere OEM code to handle the `sensorEvent` for PLDM `BootProgress`
sensor. In Ampere system, the SOC termini will have the TID 1 or 2. The
Ampere OEM EventManager will check the terminus TID to confirm about the
terminus type. Base on the value of `BootProgress` sensor, the OEM code
will add the Redfish Log to report the boot progress of Ampere SoC.

Tested:
1. Power on the host.
2. Check the Redfish SEL log.

Signed-off-by: Chau Ly <chaul@amperecomputing.com>
Signed-off-by: Thu Nguyen <thu@os.amperecomputing.com>
Change-Id: Icc51537ef17ee8eb4b5b571eafeea7b5d7763cbe