950ff459 | 24-Apr-2024 |
Matt Spinler <spinler@us.ibm.com> |
control:Bonnell: Increase ambient values by 4.5
Increase any values referencing the ambient temperature by 4.5 degrees to account for the fact that the actual temperature is 4.5 degrees higher than
control:Bonnell: Increase ambient values by 4.5
Increase any values referencing the ambient temperature by 4.5 degrees to account for the fact that the actual temperature is 4.5 degrees higher than what the sensor shows.
Signed-off-by: Matt Spinler <spinler@us.ibm.com> Change-Id: I2441c68676a716f7d5324b81bb48102187ab600f
show more ...
|
51465352 | 09-Apr-2024 |
Matt Spinler <spinler@us.ibm.com> |
control:Bonnell: Remove hot PCIe cards
It turns out that Bonnell doesn't have any 'hot' pcie cards, so the floor can just be based on ambient and altitude.
This commit removes the cards from pcie_c
control:Bonnell: Remove hot PCIe cards
It turns out that Bonnell doesn't have any 'hot' pcie cards, so the floor can just be based on ambient and altitude.
This commit removes the cards from pcie_cards.json and removes any PCIe floor index values from the mapped_floor action in events.json. It still leaves the infrastructure to keep things more common with the other IBM systems, and to make it easier to add in a card if/when a hot one comes into plan.
There is also a code update needed to allow an empty pcie_cards.json file.
Tested: Floors are set appropriately based on the altitude and ambient.
Signed-off-by: Matt Spinler <spinler@us.ibm.com> Change-Id: I10e6904602c7abf61121f7c610059f164405b758
show more ...
|