# 41d507e5 05-Oct-2021 Shantappa Teekappanavar <sbteeks@yahoo.com>

Watchdog timeout support in SBE boot window

Added support to handle SBE boot failure when watchdog
times out in the SBE boot window. FFDC information from SBE
is captured using libph

Watchdog timeout support in SBE boot window

Added support to handle SBE boot failure when watchdog
times out in the SBE boot window. FFDC information from SBE
is captured using libphal provided API, and the SBE specific
PEL for a valid FFDC is created. In case the error is related
to SBE timeout or no FFDC data then SBE dump to capture additional
debug data is initiated.

Tested: verified PEL log
root@p10bmc:~# peltool -l
{
"0x50000332": {
"SRC": "BD123504",
"Message": "timeout reported during SBE boot
process",
"PLID": "0x50000332",
"CreatorID": "BMC",
"Subsystem": "Processor Chip Cache",
"Commit Time": "10/04/2021 18:25:27",
"Sev": "Unrecoverable Error",
"CompID": "0x3500"
}
}

- Verified SBE dump was collected
Steps used:
1. obmcutil poweroff
2. istep -s0
3. systemctl start org.open_power.Dump.Manager.service
4. systemctl start openpower-debug-collector-watchdog@0.service
5. Check journal log to see SBE dump requested, dump entry created
and the dump is completed
journalctl -f -t watchdog_timeout
6. Verify the SBE dump:
ls /var/lib/phosphor-debug-collector/sbedump/<dump-entry-id>

- Verified Hostboot dump was collected
Steps Used:
1. obmcutil poweroff
2. istep -s0..6
3. systemctl start org.open_power.Dump.Manager.service
4. systemctl start openpower-debug-collector-watchdog@0.service
5. Check journal log to see Hostboot dump requested, dump entry
created and the dump is completed
journalctl -f -t watchdog_timeout
6. Verify the SBE dump:
ls /var/lib/phosphor-debug-collector/hostbootdump/<dump-entry-id>

Signed-off-by: Shantappa Teekappanavar <sbteeks@yahoo.com>
Change-Id: Ibfe7cc6619cd99f303c6106e617bc636632d0940

show more ...


# 09cf3796 11-Oct-2021 Shantappa Teekappanavar <sbteeks@yahoo.com>

Remove checks for AutoReboot in watchdog timeout

Dump collector component collects the dump depending on system dump
policy setting. If the dump policy setting is Enabled, it collects th

Remove checks for AutoReboot in watchdog timeout

Dump collector component collects the dump depending on system dump
policy setting. If the dump policy setting is Enabled, it collects the
dump even when AutoReboot property is disabled. So, removing the check
for AutoReboot which was initially used as a workaround to determine
dump collection when watchdog times out.

Tested:
Disabled AutoReboot property using busctl command, and verified that
the hostboot dump was collected.

Signed-off-by: Shantappa Teekappanavar <sbteeks@yahoo.com>
Change-Id: Iddc67f19b70461424c696754c04e2d26434247b8

show more ...


# 9b6f8474 02-Sep-2021 Patrick Williams <patrick@stwcx.xyz>

exception: switch to public sdbus exception

SdBusError was intended to be a private error type inside sdbusplus.
Switch all catch locations to use the general sdbusplus::exception type.

exception: switch to public sdbus exception

SdBusError was intended to be a private error type inside sdbusplus.
Switch all catch locations to use the general sdbusplus::exception type.

Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
Change-Id: If105f4bf34fbfa8c1e337caf10ead322099840f3

show more ...


# 1ac6162d 22-Jun-2021 Shantappa Teekappanavar <sbteeks@yahoo.com>

watchdog: Collect hostboot dump when watchdog times out

The hostboot dump collection to be initiated by watchdog_timeout
is disabled by default. When watchdog times out, only error
m

watchdog: Collect hostboot dump when watchdog times out

The hostboot dump collection to be initiated by watchdog_timeout
is disabled by default. When watchdog times out, only error
message corresponding to watchdog timeout is logged. To enable
hostboot dump collection whenever watchdog times out, the meson
option 'hostboot-dump-collection' must be enabled.

Testing - with meson option 'hostboot-dump-collection' enabled:
Ran watchdog_timeout:
case-1: CurrentHostState - off, AutoReboot - false
- Verified PEL object was not created
- Verified hostboot dump was not created
- Verified the Host State changed to Quiesce

case-2: CurrentHostState - off, AutoReboot - true
- Verified PEL object was created
- Verified hostboot dump was not created
- Verified the Host State changed to Running

case-3: CurrentHostState - Running, AutoBoot - false
- Verified PEL object was not created
- Verified hostboot dump was not created
- Verified the Host State changed to Quiesce

case-4: CurrentHostState - Running, AutoBoot - true, default timeout = 300s
- Verified PEL object was created
- Verified hostboot dump was created
- Observed Host state moving to either Running or Quiesce

case-5: CurrentHostState - Running, AutoBoot - true, specified timeout = 5s
- Verified PEL object was created
- Verified hostboot dump was created
- Observed Host state moving to either Running or Quiesce

Docker Unit test: passed

Signed-off-by: Shantappa Teekappanavar <sbteeks@yahoo.com>
Change-Id: Ib92d0c2f282816fb742cf07c1cb876b2cc093c12

show more ...