Revision tags: v6.6.25, v6.6.24, v6.6.23, v6.6.16, v6.6.15, v6.6.14, v6.6.13, v6.6.12, v6.6.11, v6.6.10, v6.6.9, v6.6.8, v6.6.7, v6.6.6, v6.6.5, v6.6.4, v6.6.3, v6.6.2, v6.5.11, v6.6.1, v6.5.10, v6.6, v6.5.9, v6.5.8, v6.5.7, v6.5.6, v6.5.5, v6.5.4, v6.5.3, v6.5.2, v6.1.51, v6.5.1, v6.1.50, v6.5, v6.1.49, v6.1.48, v6.1.46, v6.1.45, v6.1.44, v6.1.43 |
|
#
7abf253a |
| 02-Aug-2023 |
xingtong.wu <xingtong.wu@siemens.com> |
platform/x86/siemens: simatic-ipc-batt: fix logical error for BX-59A
The variable "priv.devmode" is missing from if statement that leads to a logical error. Add the missing variable to the if condit
platform/x86/siemens: simatic-ipc-batt: fix logical error for BX-59A
The variable "priv.devmode" is missing from if statement that leads to a logical error. Add the missing variable to the if condition.
Fixes: c56beff20375 ("platform/x86/siemens: simatic-ipc-batt: add support for module BX-59A") Reported-by: kernel test robot <lkp@intel.com> Closes: https://lore.kernel.org/oe-kbuild-all/202308010001.BGYCSQrl-lkp@intel.com/ Reviewed-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com> Signed-off-by: xingtong.wu <xingtong.wu@siemens.com> Link: https://lore.kernel.org/r/20430802173844.2483-1-xingtong_wu@163.com Signed-off-by: Hans de Goede <hdegoede@redhat.com>
show more ...
|
#
e5d5ffa4 |
| 09-Aug-2023 |
Yang Yingliang <yangyingliang@huawei.com> |
platform/x86/siemens: simatic-ipc-batt: fix wrong pointer pass to PTR_ERR()
Fix wrong pointer pass to PTR_ERR() if devm_gpiod_get_index() fails.
Fixes: 917f54340794 ("platform/x86: simatic-ipc: add
platform/x86/siemens: simatic-ipc-batt: fix wrong pointer pass to PTR_ERR()
Fix wrong pointer pass to PTR_ERR() if devm_gpiod_get_index() fails.
Fixes: 917f54340794 ("platform/x86: simatic-ipc: add CMOS battery monitoring") Signed-off-by: Yang Yingliang <yangyingliang@huawei.com> Reviewed-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com> Link: https://lore.kernel.org/r/20230809081227.1221267-1-yangyingliang@huawei.com Signed-off-by: Hans de Goede <hdegoede@redhat.com>
show more ...
|
#
c56beff2 |
| 31-Jul-2023 |
xingtong.wu <xingtong.wu@siemens.com> |
platform/x86/siemens: simatic-ipc-batt: add support for module BX-59A
This is used for the Siemens Simatic IPC BX-59A, which can monitor the voltage of the CMOS battery with two bits that indicate l
platform/x86/siemens: simatic-ipc-batt: add support for module BX-59A
This is used for the Siemens Simatic IPC BX-59A, which can monitor the voltage of the CMOS battery with two bits that indicate low or empty state
Signed-off-by: xingtong.wu <xingtong.wu@siemens.com> Link: https://lore.kernel.org/r/20230731072148.4781-1-xingtong_wu@163.com Reviewed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
show more ...
|
#
d0563dd3 |
| 28-Jul-2023 |
xingtong.wu <xingtong.wu@siemens.com> |
platform/x86/siemens: simatic-ipc-batt: fix bat reading in BX_21A
There was a case missing in a switch statement which lead to that model not actually reading the GPIOs. That switch statement got si
platform/x86/siemens: simatic-ipc-batt: fix bat reading in BX_21A
There was a case missing in a switch statement which lead to that model not actually reading the GPIOs. That switch statement got simplified now. Additionally on that model we need to initialize one pin differently. As a drive-by finding also add a missing newline.
Fixes: 917f54340794 ("platform/x86: simatic-ipc: add CMOS battery monitoring") Reported-by: Henning Schild <henning.schild@siemens.com> Signed-off-by: xingtong.wu <xingtong.wu@siemens.com> Signed-off-by: Henning Schild <henning.schild@siemens.com> Link: https://lore.kernel.org/r/20230728083651.19747-1-henning.schild@siemens.com Reviewed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
show more ...
|
Revision tags: v6.1.42, v6.1.41, v6.1.40 |
|
#
9bc289b8 |
| 19-Jul-2023 |
Henning Schild <henning.schild@siemens.com> |
platform/x86: Move all simatic ipc drivers to the subdirectory siemens
With more files around move everything to a subdirectory. Users will only see the several options once they enable the main one
platform/x86: Move all simatic ipc drivers to the subdirectory siemens
With more files around move everything to a subdirectory. Users will only see the several options once they enable the main one.
Suggested-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Henning Schild <henning.schild@siemens.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Link: https://lore.kernel.org/r/20230719153518.13073-4-henning.schild@siemens.com Reviewed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
show more ...
|