Revision tags: v6.6.25, v6.6.24, v6.6.23, v6.6.16, v6.6.15, v6.6.14, v6.6.13, v6.6.12, v6.6.11, v6.6.10, v6.6.9, v6.6.8, v6.6.7, v6.6.6, v6.6.5, v6.6.4, v6.6.3, v6.6.2, v6.5.11, v6.6.1, v6.5.10, v6.6, v6.5.9, v6.5.8, v6.5.7, v6.5.6, v6.5.5, v6.5.4, v6.5.3, v6.5.2, v6.1.51, v6.5.1, v6.1.50, v6.5, v6.1.49, v6.1.48, v6.1.46, v6.1.45, v6.1.44, v6.1.43, v6.1.42, v6.1.41, v6.1.40, v6.1.39, v6.1.38, v6.1.37
# bec61a29 30-Jun-2023 Damian Muszynski <damian.muszynski@intel.com>

crypto: qat - add heartbeat counters check

A firmware update for QAT GEN2 changed the format of a data
structure used to report the heartbeat counters.

To support all firmware versions, extend the

crypto: qat - add heartbeat counters check

A firmware update for QAT GEN2 changed the format of a data
structure used to report the heartbeat counters.

To support all firmware versions, extend the heartbeat logic
with an algorithm that detects the number of counters returned
by firmware. The algorithm detects the number of counters to
be used (and size of the corresponding data structure) by the
comparison the expected size of the data in memory, with the data
which was written by the firmware.

Firmware detection is done one time during the first read of heartbeat
debugfs file to avoid increasing the time needed to load the module.

Signed-off-by: Damian Muszynski <damian.muszynski@intel.com>
Reviewed-by: Giovanni Cabiddu <giovanni.cabiddu@intel.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>

show more ...


# 359b84f8 30-Jun-2023 Damian Muszynski <damian.muszynski@intel.com>

crypto: qat - add heartbeat feature

Under some circumstances, firmware in the QAT devices could become
unresponsive. The Heartbeat feature provides a mechanism to detect
unresponsive devices.

The Q

crypto: qat - add heartbeat feature

Under some circumstances, firmware in the QAT devices could become
unresponsive. The Heartbeat feature provides a mechanism to detect
unresponsive devices.

The QAT FW periodically writes to memory a set of counters that allow
to detect the liveness of a device. This patch adds logic to enable
the reporting of those counters, analyze them and report if a device
is alive or not.

In particular this adds
(1) heartbeat enabling, reading and detection logic
(2) reporting of heartbeat status and configuration via debugfs
(3) documentation for the newly created sysfs entries
(4) configuration of FW settings related to heartbeat, e.g. tick period
(5) logic to convert time in ms (provided by the user) to clock ticks

This patch introduces a new folder in debugfs called heartbeat with the
following attributes:
- status
- queries_sent
- queries_failed
- config

All attributes except config are reading only. In particular:
- `status` file returns 0 when device is operational and -1 otherwise.
- `queries_sent` returns the total number of heartbeat queries sent.
- `queries_failed` returns the total number of heartbeat queries failed.
- `config` allows to adjust the frequency at which the firmware writes
counters to memory. This period is given in milliseconds and it is
fixed for GEN4 devices.

Signed-off-by: Damian Muszynski <damian.muszynski@intel.com>
Reviewed-by: Giovanni Cabiddu <giovanni.cabiddu@intel.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>