1Voltage/Current regulator 2 3Binding: 4The regulator devices don't use the "compatible" property. The binding is done 5by the prefix of regulator node's name, or, if this fails, by the prefix of the 6regulator's "regulator-name" property. Usually the pmic I/O driver will provide 7the array of 'struct pmic_child_info' with the prefixes and compatible drivers. 8The bind is done by calling function: pmic_bind_childs(). 9Example drivers: 10pmic: drivers/power/pmic/max77686.c 11regulator: drivers/power/regulator/max77686.c 12 13For the node name e.g.: "prefix[:alpha:]num { ... }": 14- the driver prefix should be: "prefix" - case sensitive 15- the node name's "num" is set as "dev->driver_data" on bind 16 17Example the prefix "ldo" will pass for: "ldo1", "ldo@1", "ldoreg@1, ... 18 19Binding by means of the node's name is preferred. However if the node names 20would produce ambiguous prefixes (like "regulator@1" and "regualtor@11") and you 21can't or do not want to change them then binding against the "regulator-name" 22property is possible. The syntax for the prefix of the "regulator-name" property 23is the same as the one for the regulator's node name. 24Use case: a regulator named "regulator@1" to be bound to a driver named 25"LDO_DRV" and a regulator named "regualator@11" to be bound to an other driver 26named "BOOST_DRV". Using prefix "regualtor@1" for driver matching would load 27the same driver for both regulators, hence the prefix is ambiguous. 28 29Optional properties: 30- regulator-name: a string, required by the regulator uclass, used for driver 31 binding if binding by node's name prefix fails 32- regulator-min-microvolt: a minimum allowed Voltage value 33- regulator-max-microvolt: a maximum allowed Voltage value 34- regulator-min-microamp: a minimum allowed Current value 35- regulator-max-microamp: a maximum allowed Current value 36- regulator-always-on: regulator should never be disabled 37- regulator-boot-on: enabled by bootloader/firmware 38 39Note 40The "regulator-name" constraint is used for setting the device's uclass 41platform data '.name' field. And the regulator device name is set from 42it's node name. If "regulator-name" is not provided in dts, node name 43is chosen for setting the device's uclass platform data '.name' field. 44 45Other kernel-style properties, are currently not used. 46 47Note: 48For the regulator autoset from constraints, the framework expects that: 49- regulator-min-microvolt is equal to regulator-max-microvolt 50- regulator-min-microamp is equal to regulator-max-microamp 51- regulator-always-on or regulator-boot-on is set 52 53Example: 54ldo0 { 55 /* Optional */ 56 regulator-name = "VDDQ_EMMC_1.8V"; 57 regulator-min-microvolt = <1800000>; 58 regulator-max-microvolt = <1800000>; 59 regulator-min-microamp = <100000>; 60 regulator-max-microamp = <100000>; 61 regulator-always-on; 62 regulator-boot-on; 63}; 64