1 #pragma once 2 3 #include "sensors/sensor.hpp" 4 5 #include <string> 6 7 namespace pid_control 8 { 9 10 /** 11 * In a Zone you have a set of PIDs which feed each other. Fan PIDs are fed set 12 * points from Thermal PIDs. 13 */ 14 class ZoneInterface 15 { 16 public: 17 virtual ~ZoneInterface() = default; 18 19 /** If the zone implementation supports logging, initialize the log. */ 20 virtual void initializeLog(void) = 0; 21 /** If the zone implementation supports logging, write string to log. */ 22 virtual void writeLog(const std::string& value) = 0; 23 24 /** Return a pointer to the sensor specified by name. */ 25 virtual Sensor* getSensor(const std::string& name) = 0; 26 27 /* updateFanTelemetry() and updateSensors() both clear the failsafe state 28 * for a sensor if it's no longer in that state. 29 */ 30 /** For each fan input in the zone, read each to update the cachedValue and 31 * check if the fan is beyond its timeout to trigger a failsafe condition. 32 */ 33 virtual void updateFanTelemetry(void) = 0; 34 /** For each thermal input in the zone, read each to update the cachedValue 35 * and check if the sensor is beyond its timeout to trigger a failsafe 36 * condition. 37 */ 38 virtual void updateSensors(void) = 0; 39 /** For each fan and thermal input in the zone, set the cachedValue to 0 and 40 * set the input as failsafe - to default the zone to failsafe before it 41 * starts processing values to control fans. 42 */ 43 virtual void initializeCache(void) = 0; 44 /** Return cached value for sensor by name. */ 45 virtual double getCachedValue(const std::string& name) = 0; 46 47 /** Add a set point value for the Max Set Point computation. */ 48 virtual void addSetPoint(double setpoint) = 0; 49 /** Clear all set points specified via addSetPoint */ 50 virtual void clearSetPoints(void) = 0; 51 52 /** Add maximum RPM value to drive fan pids. */ 53 virtual void addRPMCeiling(double ceiling) = 0; 54 /** Clear any RPM value set with addRPMCeiling. */ 55 virtual void clearRPMCeilings(void) = 0; 56 57 /** Compute the value returned by getMaxSetPointRequest - called from the 58 * looping mechanism before triggering any Fan PIDs. The value computed is 59 * used by each fan PID. 60 */ 61 virtual void determineMaxSetPointRequest(void) = 0; 62 /** Given the set points added via addSetPoint, return the maximum value - 63 * called from the PID loop that uses that value to drive the fans. 64 */ 65 virtual double getMaxSetPointRequest() const = 0; 66 67 /** Return if the zone has any sensors in fail safe mode. */ 68 virtual bool getFailSafeMode() const = 0; 69 /** Return the rpm or pwm percent value to drive fan pids when zone is in 70 * fail safe. 71 */ 72 virtual double getFailSafePercent() const = 0; 73 74 /** Return if the zone is set to manual mode. false equates to automatic 75 * mode (the default). 76 */ 77 virtual bool getManualMode(void) const = 0; 78 79 /** For each fan pid, do processing. */ 80 virtual void processFans(void) = 0; 81 /** For each thermal pid, do processing. */ 82 virtual void processThermals(void) = 0; 83 }; 84 85 } // namespace pid_control 86