1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 8 "SRC": 9 { 10 "ReasonCode": "0x1001", 11 "Words6To9": 12 { 13 "6": 14 { 15 "Description": "Timeout in ms", 16 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 17 } 18 } 19 }, 20 21 "Documentation": 22 { 23 "Description": "This is a generic timeout error", 24 "Message": "An operation timed out", 25 "Notes": [ 26 "The journal should contain more information" 27 ] 28 } 29 }, 30 31 { 32 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 33 "Subsystem": "bmc_firmware", 34 35 "SRC": 36 { 37 "ReasonCode": "0x1002", 38 "Words6To9": 39 { 40 } 41 }, 42 43 "Documentation": 44 { 45 "Description": "BMC code had a generic internal failure", 46 "Message": "An application had an internal failure", 47 "Notes": [ 48 "The journal should contain more information" 49 ] 50 } 51 }, 52 53 { 54 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 55 "Subsystem": "user_error", 56 57 "SRC": 58 { 59 "ReasonCode": "0x1003", 60 "Words6To9": 61 { 62 } 63 }, 64 65 "Documentation": 66 { 67 "Description": "BMC code was given an invalid argument", 68 "Message": "Code was given an invalid argument", 69 "Notes": [ 70 "The journal should contain more information" 71 ] 72 } 73 }, 74 { 75 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 76 "Subsystem": "user_error", 77 78 "SRC": 79 { 80 "ReasonCode": "0x1004", 81 "Words6To9": 82 { 83 } 84 }, 85 86 "Documentation": 87 { 88 "Description": "An operation failed due to insufficient permission", 89 "Message": "An operation failed due to unsufficient permission", 90 "Notes": [ 91 "The journal should contain more information" 92 ] 93 } 94 }, 95 96 { 97 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 98 "Subsystem": "user_error", 99 100 "SRC": 101 { 102 "ReasonCode": "0x1005", 103 "Words6To9": 104 { 105 } 106 }, 107 108 "Documentation": 109 { 110 "Description": "An operation failed because it isn't allowed", 111 "Message": "An operation failed because it isn't allowed", 112 "Notes": [ 113 "The journal should contain more information" 114 ] 115 } 116 }, 117 118 { 119 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 120 "Subsystem": "user_error", 121 122 "SRC": 123 { 124 "ReasonCode": "0x1006", 125 "Words6To9": 126 { 127 } 128 }, 129 130 "Documentation": 131 { 132 "Description": "The server's CA certificate has not been provided", 133 "Message": "The server's CA certificate has not been provided" 134 } 135 }, 136 137 { 138 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 139 "Subsystem": "cec_chip_iface", 140 141 "SRC": 142 { 143 "ReasonCode": "0x1007", 144 "Words6To9": 145 { 146 "6": 147 { 148 "Description": "errno of the failure", 149 "AdditionalDataPropSource": "CALLOUT_ERRNO" 150 } 151 } 152 }, 153 154 "Documentation": 155 { 156 "Description": "Sensor device read failure", 157 "Message": "There was a failure when reading a sensor device", 158 "Notes": [ 159 "The severity is set by the creator.", 160 "The action flags are set automatically by the code.", 161 "Callouts added based on CALLOUT_DEVICE_PATH." 162 ] 163 } 164 }, 165 166 { 167 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 168 "Subsystem": "cec_chip_iface", 169 170 "SRC": 171 { 172 "ReasonCode": "0x1008", 173 "Words6To9": 174 { 175 "6": 176 { 177 "Description": "errno of the failure", 178 "AdditionalDataPropSource": "CALLOUT_ERRNO" 179 } 180 } 181 }, 182 183 "Documentation": 184 { 185 "Description": "Device read failure", 186 "Message": "There was a failure when reading a hardware device", 187 "Notes": [ 188 "The severity is set by the creator.", 189 "The action flags are set automatically by the code.", 190 "Callouts added based on CALLOUT_DEVICE_PATH." 191 ] 192 } 193 }, 194 195 { 196 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 197 "Subsystem": "cec_chip_iface", 198 199 "SRC": 200 { 201 "ReasonCode": "0x1009", 202 "Words6To9": 203 { 204 "6": 205 { 206 "Description": "errno of the failure", 207 "AdditionalDataPropSource": "CALLOUT_ERRNO" 208 } 209 } 210 }, 211 212 "Documentation": 213 { 214 "Description": "Device write failure", 215 "Message": "There was a failure when writing to a hardware device", 216 "Notes": [ 217 "The severity is set by the creator.", 218 "The action flags are set automatically by the code.", 219 "Callouts added based on CALLOUT_DEVICE_PATH" 220 ] 221 } 222 }, 223 224 { 225 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 226 "Subsystem": "cec_chip_iface", 227 228 "SRC": 229 { 230 "ReasonCode": "0x100A", 231 "Words6To9": 232 { 233 "6": 234 { 235 "Description": "errno of the failure", 236 "AdditionalDataPropSource": "CALLOUT_ERRNO" 237 } 238 } 239 }, 240 241 "Documentation": 242 { 243 "Description": "Device write failure", 244 "Message": "There was a failure when writing to a hardware device", 245 "Notes": [ 246 "The severity is set by the creator.", 247 "The action flags are set automatically by the code.", 248 "Callouts added based on CALLOUT_DEVICE_PATH" 249 ] 250 } 251 }, 252 253 { 254 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 255 "Subsystem": "bmc_firmware", 256 "Severity": "non_error", 257 258 "SRC": 259 { 260 "ReasonCode": "0x2001", 261 "Words6To9": 262 { 263 "6": 264 { 265 "Description": "The bad PEL ID", 266 "AdditionalDataPropSource": "BAD_ID" 267 } 268 } 269 }, 270 271 "Documentation": 272 { 273 "Description": "The BMC sent the host a malformed PEL", 274 "Message": "The BMC sent the host a malformed PEL", 275 "Notes": [ 276 "The host firmware rejected that PEL." 277 ] 278 } 279 }, 280 281 { 282 "Name": "org.open_power.Logging.Error.BadHostPEL", 283 "Subsystem": "platform_firmware", 284 "Severity": "unrecoverable", 285 286 "SRC": 287 { 288 "ReasonCode": "0x2002", 289 "Words6To9": 290 { 291 "6": 292 { 293 "Description": "The PLID of the invalid PEL", 294 "AdditionalDataPropSource": "PLID" 295 }, 296 "7": 297 { 298 "Description": "The corresponding OpenBMC event log ID", 299 "AdditionalDataPropSource": "OBMC_LOG_ID" 300 }, 301 "8": 302 { 303 "Description": "The size of the invalid PEL", 304 "AdditionalDataPropSource": "PEL_SIZE" 305 } 306 } 307 }, 308 309 "Documentation": 310 { 311 "Description": "The host sent the BMC an invalid PEL", 312 "Message": "The host sent the BMC an invalid PEL", 313 "Notes": [ 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.TestError1", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2003", 326 "Words6To9": 327 { 328 } 329 }, 330 331 "Callouts": [ 332 { 333 "CalloutList": [ 334 {"Priority": "high", "Procedure": "bmc_code"}, 335 {"Priority": "medium", "SymbolicFRU": "service_docs"} 336 ] 337 } 338 ], 339 340 "Documentation": 341 { 342 "Description": "An error for testing", 343 "Message": "This is a test error" 344 } 345 }, 346 347 { 348 "Name": "xyz.openbmc_project.Logging.Error.Default", 349 "Subsystem": "other_na", 350 351 "SRC": 352 { 353 "ReasonCode": "0x2004", 354 "Words6To9": 355 { 356 } 357 }, 358 359 "Documentation": 360 { 361 "Description": "This entry is used when no other matching entry is found", 362 "Message": "Unknown (Original event not in message registry)", 363 "Notes": [ 364 "This is used when the actual error name isn't found in ", 365 "the registry. The original error name will be stored ", 366 "in the UserData section that contains the AdditionalData ", 367 "properties using the key ERROR_NAME.", 368 "This error may contain callouts if the creator passed ", 369 "them in.", 370 "The severity is set by the creator.", 371 "If this error is seen, then a code change needs to be ", 372 "made to add the missing error entry to this registry." 373 ] 374 } 375 }, 376 377 { 378 "Name": "org.open_power.PHAL.Error.Boot", 379 "Subsystem": "cec_hardware", 380 "ComponentID": "0x3000", 381 "Severity": "unrecoverable", 382 383 "SRC": 384 { 385 "ReasonCode": "0x3001", 386 "Words6To9": 387 { 388 } 389 }, 390 391 "Documentation": 392 { 393 "Description": "Failure occured during boot process", 394 "Message": "Failure occured during boot process", 395 "Notes": [ 396 "Debug traces will be captured in AdditionalData section" 397 ] 398 } 399 }, 400 401 { 402 "Name": "org.open_power.PHAL.Error.PrePowerOff", 403 "Subsystem": "cec_hardware", 404 "ComponentID": "0x3000", 405 406 "SRC": 407 { 408 "ReasonCode": "0x3002", 409 "Words6To9": 410 { 411 } 412 }, 413 414 "Documentation": 415 { 416 "Description": "Failure occurred during PHAL pre-poweroff operations", 417 "Message": "Failure occurred during PHAL pre-poweroff operations", 418 "Notes": [ 419 "Severity needs to be set based on needs for this registry.", 420 "FFDC (First Failure Data Collection) will be collected ", 421 "and added into PEL." 422 ] 423 } 424 }, 425 426 { 427 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 428 "Subsystem": "processor_chip", 429 "ComponentID": "0x3500", 430 431 "SRC": 432 { 433 "ReasonCode": "0x3500", 434 "Words6To9": 435 { 436 "6": 437 { 438 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 439 "AdditionalDataPropSource": "SRC6" 440 } 441 } 442 }, 443 444 "Documentation": 445 { 446 "Description": "chipop failure with SBE provided FFDC", 447 "Message": "chipop request failure reported by SBE", 448 "Notes": [ 449 "The severity is set by the creator.", 450 "Callouts added based on SBE provided FFDC.", 451 "SBE provided additional debug data included as part of the", 452 "additional user data section." 453 ] 454 } 455 }, 456 457 { 458 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 459 "Subsystem": "processor_chip", 460 "ComponentID": "0x3500", 461 462 "SRC": 463 { 464 "ReasonCode": "0x3501", 465 "Words6To9": 466 { 467 "6": 468 { 469 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 470 "AdditionalDataPropSource": "SRC6" 471 } 472 } 473 }, 474 475 "Documentation": 476 { 477 "Description": "SBE chipop timeout", 478 "Message": "chipop timeout reported during SBE communication", 479 "Notes": [ 480 "The severity is set by the creator.", 481 "Check SBE Dump associated to this error to debug the failure." 482 ] 483 } 484 }, 485 486 { 487 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 488 "Subsystem": "processor_chip", 489 "ComponentID": "0x3500", 490 491 "SRC": 492 { 493 "ReasonCode": "0x3502", 494 "Words6To9": 495 { 496 "6": 497 { 498 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 499 "AdditionalDataPropSource": "SRC6" 500 }, 501 "7": 502 { 503 "Description": "Value of SBE state", 504 "AdditionalDataPropSource": "SRC7" 505 } 506 } 507 }, 508 509 "Documentation": 510 { 511 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 512 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 513 "Notes": [ 514 "The severity is set by the creator." 515 ] 516 } 517 }, 518 519 { 520 "Name": "org.open_power.Attn.Error.Terminate", 521 "Subsystem": "cec_hardware", 522 "Severity": "non_error", 523 524 "SRC": 525 { 526 "ReasonCode": "0xD138", 527 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 528 "Words6To9": 529 { 530 } 531 }, 532 533 "Documentation": 534 { 535 "Description": "Status shows TI special attention active", 536 "Message": "TI special attention detected", 537 "Notes": [ 538 "This entry is for any TI special attention event ", 539 "reported by the attention handler component" 540 ] 541 } 542 }, 543 544 { 545 "Name": "org.open_power.Attn.Error.Fail", 546 "Subsystem": "bmc_firmware", 547 "Severity": "unrecoverable_loss_of_function", 548 549 "SRC": 550 { 551 "ReasonCode": "0xD13E", 552 "Words6To9": 553 { 554 "6": 555 { 556 "Description": "Error code from attention handler", 557 "AdditionalDataPropSource": "ERROR_CODE" 558 } 559 } 560 }, 561 "Documentation": 562 { 563 "Description": "The attention handler encountered an error", 564 "MessageArgSources" : ["SRCWord6"], 565 "Message": "Attention handler error %1", 566 "Notes": [ 567 "Attention handler will provide error code" 568 ] 569 } 570 }, 571 572 { 573 "Name": "org.open_power.Attn.Error.Vital", 574 "Subsystem": "processor_chip", 575 "Severity": "critical", 576 577 "SRC": 578 { 579 "ReasonCode": "0xD16D", 580 "Words6To9": 581 { 582 } 583 }, 584 585 "Documentation": 586 { 587 "Description": "Status shows SBE vital attention active", 588 "Message": "SBE vital attention detected", 589 "Notes": [ 590 "This entry is for any SBE vital attention event ", 591 "reported by the attention handler component" 592 ] 593 } 594 }, 595 596 { 597 "Name": "org.open_power.HwDiags.Error.Checkstop", 598 "Subsystem": "cec_hardware", 599 "ActionFlags": [ "service_action", "report", "call_home" ], 600 601 "SRC": 602 { 603 "ReasonCode": "0xE510", 604 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 605 "Words6To9": 606 { 607 "6": 608 { 609 "Description": "[0:15] chip model, [16:23] reserved, [24:31] chip EC level", 610 "AdditionalDataPropSource": "SRC6" 611 }, 612 "7": 613 { 614 "Description": "[0:15] chip position, [16:23] unused, [24:31] signature attn type", 615 "AdditionalDataPropSource": "SRC7" 616 }, 617 "8": 618 { 619 "Description": "[0:15] signature ID, [16:23] signature instance, [24:31] signature bit position", 620 "AdditionalDataPropSource": "SRC8" 621 } 622 } 623 }, 624 625 "Documentation": 626 { 627 "Description": "A system checkstop attention has occurred", 628 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 629 "Message": "hw-diags signature: %1 %2 %3" 630 } 631 }, 632 633 { 634 "Name": "org.open_power.HwDiags.Error.Predictive", 635 "Subsystem": "cec_hardware", 636 "ActionFlags": [ "service_action", "report", "call_home" ], 637 638 "SRC": 639 { 640 "ReasonCode": "0xE511", 641 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 642 "Words6To9": 643 { 644 "6": 645 { 646 "Description": "[0:15] chip model, [16:23] reserved, [24:31] chip EC level", 647 "AdditionalDataPropSource": "SRC6" 648 }, 649 "7": 650 { 651 "Description": "[0:15] chip position, [16:23] unused, [24:31] signature attn type", 652 "AdditionalDataPropSource": "SRC7" 653 }, 654 "8": 655 { 656 "Description": "[0:15] signature ID, [16:23] signature instance, [24:31] signature bit position", 657 "AdditionalDataPropSource": "SRC8" 658 } 659 } 660 }, 661 662 "Documentation": 663 { 664 "Description": "A hardware attention requiring service has occurred", 665 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 666 "Message": "hw-diags signature: %1 %2 %3" 667 } 668 }, 669 670 { 671 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 672 "Subsystem": "power_supply", 673 "Severity": "unrecoverable_redundancy_loss", 674 "ActionFlags": ["service_action", "report"], 675 "ComponentID": "0x2700", 676 677 "SRC": { 678 "Type": "11", 679 "ReasonCode": "0x15F0", 680 "Words6To9": {} 681 }, 682 683 "Callouts": [ 684 { 685 "CalloutList": [ 686 { "Priority": "high", "SymbolicFRU": "pwrsply" } 687 ] 688 } 689 ], 690 691 "Documentation": { 692 "Description": "Power Supply input power fault", 693 "Message": "A power supply has indicated an input or under voltage condition.", 694 "Notes": [ 695 "Check the power supply cabling and/or input power ", 696 "source. The PWRSPLY procedure is used rather than ", 697 "calling out a location code, as typically these faults ", 698 "are related to the supplied power, the cable, or the ", 699 "cable connectors. If the input fault resolves down to an ", 700 "issue with the power supply itself, the power supply ", 701 "indicating this input fault should be called out. Add the ", 702 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 703 "CALLOUT_PRIORITY to something other than high." 704 ] 705 } 706 }, 707 708 { 709 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 710 "Subsystem": "power_supply", 711 "Severity": "unrecoverable_redundancy_loss", 712 "ActionFlags": ["service_action", "report", "call_home"], 713 "ComponentID": "0x2700", 714 715 "SRC": { 716 "Type": "11", 717 "ReasonCode": "0x15F1", 718 "Words6To9": {} 719 }, 720 721 "Documentation": { 722 "Description": "Power Supply power fault", 723 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 724 "Notes": [ 725 "The power supply reporting the fault should be called ", 726 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 727 "specific fault, STATUS_* details, and code level in the ", 728 "AdditionalData section." 729 ] 730 } 731 }, 732 733 { 734 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 735 "Subsystem": "power_supply", 736 "Severity": "unrecoverable", 737 "ActionFlags": ["service_action", "report", "call_home"], 738 "ComponentID": "0x2700", 739 740 "SRC": { 741 "Type": "11", 742 "ReasonCode": "0x15F2", 743 "Words6To9": {} 744 }, 745 746 "Documentation": { 747 "Description": "Power Supply non-power fault", 748 "Message": "A communication failure occurred talking to the power supply", 749 "Notes": [ 750 "Communication problems with the power supply could be ", 751 "the power supply, or any hardware between it and the ", 752 "BMC. Reporting the error should be passing in a call ", 753 "out using CALLOUT_DEVICE_PATH." 754 ] 755 } 756 }, 757 758 { 759 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 760 "Subsystem": "power_supply", 761 "Severity": "unrecoverable_redundancy_loss", 762 "ActionFlags": ["service_action", "report", "call_home"], 763 "ComponentID": "0x2700", 764 765 "SRC": { 766 "Type": "11", 767 "ReasonCode": "0x15F6", 768 "Words6To9": {} 769 }, 770 771 "Callouts": [ 772 { 773 "CalloutList": [ 774 { 775 "Priority": "high", 776 "SymbolicFRUTrusted": "pwrsply", 777 "UseInventoryLocCode": true 778 } 779 ] 780 } 781 ], 782 783 "Documentation": { 784 "Description": "Power Supply is missing", 785 "Message": "A power supply that should be present is missing", 786 "Notes": [ 787 "The CalloutList should use the PWRSPLY symbolic FRU ", 788 "with the trusted location code property. The ", 789 "location code in this callout is obtained from ", 790 "the passed in CALLOUT_INVENTORY_PATH value." 791 ] 792 } 793 }, 794 795 { 796 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 797 "Subsystem": "power", 798 "ActionFlags": [ "report", "service_action" ], 799 "Severity": "unrecoverable", 800 "ComponentID": "0x2700", 801 802 "SRC": 803 { 804 "Type": "11", 805 "ReasonCode": "0x00AC", 806 "Words6To9": {}, 807 "PowerFault": true 808 }, 809 810 "Callouts": [ 811 { 812 "CalloutList": [ 813 { "Priority": "high", "SymbolicFRU": "ac_module"} 814 ] 815 } 816 ], 817 818 "Documentation": { 819 "Description": "Input power was lost while the system was powered on.", 820 "Message": "Input power was lost while the system was powered on.", 821 "Notes": [ 822 "Input power was lost while system powered on.", 823 "The CalloutList should use the ACMODUL symbolic FRU." 824 ] 825 } 826 }, 827 828 { 829 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 830 "Subsystem": "power_sequencer", 831 "ComponentID": "0x2700", 832 833 "SRC": { 834 "Type": "11", 835 "ReasonCode": "0x2600", 836 "Words6To9": {} 837 }, 838 839 "Callouts": [ 840 { 841 "CalloutList": [ 842 { "Priority": "high", "SymbolicFRU": "pgood_part" } 843 ] 844 } 845 ], 846 847 "Documentation": { 848 "Description": "A power off was issued because a power fault was detected", 849 "Message": "A power off was issued because a power fault was detected", 850 "Notes": [ 851 ] 852 } 853 }, 854 855 { 856 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 857 "Subsystem": "power_sequencer", 858 "ComponentID": "0x2700", 859 860 "SRC": { 861 "Type": "11", 862 "ReasonCode": "0x2610", 863 "Words6To9": {} 864 }, 865 866 "CalloutsUsingAD": { 867 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 868 { 869 "ADValue": "PCIE_SLOT0", "Callouts": [ 870 { 871 "CalloutList": [ 872 { "Priority": "high", "LocCode": "P0-C0" }, 873 { "Priority": "medium", "LocCode": "P0" } 874 ] 875 } 876 ] 877 }, 878 { 879 "ADValue": "PCIE_SLOT1", "Callouts": [ 880 { 881 "CalloutList": [ 882 { "Priority": "high", "LocCode": "P0-C1" }, 883 { "Priority": "medium", "LocCode": "P0" } 884 ] 885 } 886 ] 887 }, 888 { 889 "ADValue": "PCIE_SLOT2", "Callouts": [ 890 { 891 "CalloutList": [ 892 { "Priority": "high", "LocCode": "P0-C2" }, 893 { "Priority": "medium", "LocCode": "P0" } 894 ] 895 } 896 ] 897 }, 898 { 899 "ADValue": "PCIE_SLOT3", "Callouts": [ 900 { 901 "CalloutList": [ 902 { "Priority": "high", "LocCode": "P0-C3" }, 903 { "Priority": "medium", "LocCode": "P0" } 904 ] 905 } 906 ] 907 }, 908 { 909 "ADValue": "PCIE_SLOT4", "Callouts": [ 910 { 911 "CalloutList": [ 912 { "Priority": "high", "LocCode": "P0-C4" }, 913 { "Priority": "medium", "LocCode": "P0" } 914 ] 915 } 916 ] 917 }, 918 { 919 "ADValue": "PCIE_SLOT7", "Callouts": [ 920 { 921 "CalloutList": [ 922 { "Priority": "high", "LocCode": "P0-C7" }, 923 { "Priority": "medium", "LocCode": "P0" } 924 ] 925 } 926 ] 927 }, 928 { 929 "ADValue": "PCIE_SLOT8", "Callouts": [ 930 { 931 "CalloutList": [ 932 { "Priority": "high", "LocCode": "P0-C8" }, 933 { "Priority": "medium", "LocCode": "P0" } 934 ] 935 } 936 ] 937 }, 938 { 939 "ADValue": "PCIE_SLOT9", "Callouts": [ 940 { 941 "CalloutList": [ 942 { "Priority": "high", "LocCode": "P0-C9" }, 943 { "Priority": "medium", "LocCode": "P0" } 944 ] 945 } 946 ] 947 }, 948 { 949 "ADValue": "PCIE_SLOT10", "Callouts": [ 950 { 951 "CalloutList": [ 952 { "Priority": "high", "LocCode": "P0-C10" }, 953 { "Priority": "medium", "LocCode": "P0" } 954 ] 955 } 956 ] 957 }, 958 { 959 "ADValue": "PCIE_SLOT11", "Callouts": [ 960 { 961 "CalloutList": [ 962 { "Priority": "high", "LocCode": "P0-C11" }, 963 { "Priority": "medium", "LocCode": "P0" } 964 ] 965 } 966 ] 967 }, 968 { 969 "ADValue": "PGOOD_12A", "Callouts": [ 970 { 971 "CalloutList": [ 972 { "Priority": "high", "SymbolicFRU": "pgood_part" } 973 ] 974 } 975 ] 976 }, 977 { 978 "ADValue": "PGOOD_12B", "Callouts": [ 979 { 980 "CalloutList": [ 981 { "Priority": "high", "SymbolicFRU": "pgood_part" } 982 ] 983 } 984 ] 985 }, 986 { 987 "ADValue": "PGOOD_12C", "Callouts": [ 988 { 989 "CalloutList": [ 990 { "Priority": "high", "SymbolicFRU": "pgood_part" } 991 ] 992 } 993 ] 994 }, 995 { 996 "ADValue": "PGOOD_12D", "Callouts": [ 997 { 998 "CalloutList": [ 999 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1000 ] 1001 } 1002 ] 1003 }, 1004 { 1005 "ADValue": "PGOOD_12L", "Callouts": [ 1006 { 1007 "CalloutList": [ 1008 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1009 ] 1010 } 1011 ] 1012 }, 1013 { 1014 "ADValue": "PGOOD_12M", "Callouts": [ 1015 { 1016 "CalloutList": [ 1017 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1018 ] 1019 } 1020 ] 1021 }, 1022 { 1023 "ADValue": "PGOOD_12N", "Callouts": [ 1024 { 1025 "CalloutList": [ 1026 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1027 ] 1028 } 1029 ] 1030 }, 1031 { 1032 "ADValue": "PGOOD_12P", "Callouts": [ 1033 { 1034 "CalloutList": [ 1035 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1036 ] 1037 } 1038 ] 1039 }, 1040 { 1041 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1042 { 1043 "CalloutList": [ 1044 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1045 ] 1046 } 1047 ] 1048 }, 1049 { 1050 "ADValue": "PGOOD_12Q", "Callouts": [ 1051 { 1052 "CalloutList": [ 1053 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1054 ] 1055 } 1056 ] 1057 }, 1058 { 1059 "ADValue": "PGOOD_12R", "Callouts": [ 1060 { 1061 "CalloutList": [ 1062 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1063 ] 1064 } 1065 ] 1066 }, 1067 { 1068 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1069 { 1070 "CalloutList": [ 1071 { "Priority": "high", "LocCode": "P0-C14" }, 1072 { "Priority": "medium", "LocCode": "P0-C15" }, 1073 { "Priority": "low", "LocCode": "P0" } 1074 ] 1075 } 1076 ] 1077 }, 1078 { 1079 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1080 { 1081 "CalloutList": [ 1082 { "Priority": "high", "LocCode": "P0-C23" }, 1083 { "Priority": "medium", "LocCode": "P0-C24" }, 1084 { "Priority": "low", "LocCode": "P0" } 1085 ] 1086 } 1087 ] 1088 }, 1089 { 1090 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1091 { 1092 "CalloutList": [ 1093 { "Priority": "high", "LocCode": "P0-C14" }, 1094 { "Priority": "medium", "LocCode": "P0-C15" }, 1095 { "Priority": "low", "LocCode": "P0" } 1096 ] 1097 } 1098 ] 1099 }, 1100 { 1101 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1102 { 1103 "CalloutList": [ 1104 { "Priority": "high", "LocCode": "P0-C23" }, 1105 { "Priority": "medium", "LocCode": "P0-C24" }, 1106 { "Priority": "low", "LocCode": "P0" } 1107 ] 1108 } 1109 ] 1110 }, 1111 { 1112 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1113 { 1114 "CalloutList": [ 1115 { "Priority": "high", "LocCode": "P0-C14" }, 1116 { "Priority": "medium", "LocCode": "P0-C15" }, 1117 { "Priority": "low", "LocCode": "P0" } 1118 ] 1119 } 1120 ] 1121 }, 1122 { 1123 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1124 { 1125 "CalloutList": [ 1126 { "Priority": "high", "LocCode": "P0-C23" }, 1127 { "Priority": "medium", "LocCode": "P0-C24" }, 1128 { "Priority": "low", "LocCode": "P0" } 1129 ] 1130 } 1131 ] 1132 }, 1133 { 1134 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1135 { 1136 "CalloutList": [ 1137 { "Priority": "high", "LocCode": "P0-C14" }, 1138 { "Priority": "medium", "LocCode": "P0-C15" }, 1139 { "Priority": "low", "LocCode": "P0" } 1140 ] 1141 } 1142 ] 1143 }, 1144 { 1145 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1146 { 1147 "CalloutList": [ 1148 { "Priority": "high", "LocCode": "P0-C23" }, 1149 { "Priority": "medium", "LocCode": "P0-C24" }, 1150 { "Priority": "low", "LocCode": "P0" } 1151 ] 1152 } 1153 ] 1154 } 1155 ] 1156 }, 1157 1158 "Documentation": { 1159 "Description": "The power sequencer chip detected a PGOOD fault", 1160 "Message": "The power sequencer chip detected a PGOOD fault", 1161 "Notes": [ 1162 ] 1163 } 1164 }, 1165 1166 { 1167 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 1168 "Subsystem": "power_sequencer", 1169 "ComponentID": "0x2700", 1170 1171 "SRC": { 1172 "Type": "11", 1173 "ReasonCode": "0x2620", 1174 "Words6To9": {} 1175 }, 1176 1177 "CalloutsUsingAD": { 1178 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 1179 { 1180 "ADValue": "12.0V", "Callouts": [ 1181 { 1182 "CalloutList": [ 1183 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1184 ] 1185 } 1186 ] 1187 }, 1188 { 1189 "ADValue": "5.0V_USB", "Callouts": [ 1190 { 1191 "CalloutList": [ 1192 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1193 { "Priority": "medium", "LocCode": "P0" } 1194 ] 1195 } 1196 ] 1197 }, 1198 { 1199 "ADValue": "5.0V_DASD", "Callouts": [ 1200 { 1201 "CalloutList": [ 1202 { "Priority": "medium", "LocCode": "P1" }, 1203 { "Priority": "medium", "LocCode": "P2" }, 1204 { "Priority": "medium", "LocCode": "P3" }, 1205 { "Priority": "low", "LocCode": "P0" } 1206 ] 1207 } 1208 ] 1209 }, 1210 { 1211 "ADValue": "3.3VA", "Callouts": [ 1212 { 1213 "CalloutList": [ 1214 { "Priority": "high", "LocCode": "P0" } 1215 ] 1216 } 1217 ] 1218 }, 1219 { 1220 "ADValue": "3.3VB", "Callouts": [ 1221 { 1222 "CalloutList": [ 1223 { "Priority": "high", "LocCode": "P0" } 1224 ] 1225 } 1226 ] 1227 }, 1228 { 1229 "ADValue": "1.5V", "Callouts": [ 1230 { 1231 "CalloutList": [ 1232 { "Priority": "high", "LocCode": "P0" } 1233 ] 1234 } 1235 ] 1236 }, 1237 { 1238 "ADValue": "1.1V", "Callouts": [ 1239 { 1240 "CalloutList": [ 1241 { "Priority": "high", "LocCode": "P0" } 1242 ] 1243 } 1244 ] 1245 }, 1246 { 1247 "ADValue": "VDDA_DCM0", "Callouts": [ 1248 { 1249 "CalloutList": [ 1250 { "Priority": "high", "LocCode": "P0-C14" }, 1251 { "Priority": "medium", "LocCode": "P0-C15" }, 1252 { "Priority": "low", "LocCode": "P0" } 1253 ] 1254 } 1255 ] 1256 }, 1257 { 1258 "ADValue": "VDDB_DCM0", "Callouts": [ 1259 { 1260 "CalloutList": [ 1261 { "Priority": "high", "LocCode": "P0-C14" }, 1262 { "Priority": "medium", "LocCode": "P0-C15" }, 1263 { "Priority": "low", "LocCode": "P0" } 1264 ] 1265 } 1266 ] 1267 }, 1268 { 1269 "ADValue": "VDDA_DCM1", "Callouts": [ 1270 { 1271 "CalloutList": [ 1272 { "Priority": "high", "LocCode": "P0-C23" }, 1273 { "Priority": "medium", "LocCode": "P0-C24" }, 1274 { "Priority": "low", "LocCode": "P0" } 1275 ] 1276 } 1277 ] 1278 }, 1279 { 1280 "ADValue": "VDDB_DCM1", "Callouts": [ 1281 { 1282 "CalloutList": [ 1283 { "Priority": "high", "LocCode": "P0-C23" }, 1284 { "Priority": "medium", "LocCode": "P0-C24" }, 1285 { "Priority": "low", "LocCode": "P0" } 1286 ] 1287 } 1288 ] 1289 }, 1290 { 1291 "ADValue": "12.0VCS", "Callouts": [ 1292 { 1293 "CalloutList": [ 1294 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1295 ] 1296 } 1297 ] 1298 }, 1299 { 1300 "ADValue": "3.3VCS", "Callouts": [ 1301 { 1302 "CalloutList": [ 1303 { "Priority": "high", "LocCode": "P0" } 1304 ] 1305 } 1306 ] 1307 }, 1308 { 1309 "ADValue": "1.1V_Current", "Callouts": [ 1310 { 1311 "CalloutList": [ 1312 { "Priority": "high", "LocCode": "P0" } 1313 ] 1314 } 1315 ] 1316 }, 1317 { 1318 "ADValue": "5.0V_USB_Current", "Callouts": [ 1319 { 1320 "CalloutList": [ 1321 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1322 { "Priority": "medium", "LocCode": "P0" } 1323 ] 1324 } 1325 ] 1326 }, 1327 { 1328 "ADValue": "5.0V_DASD_Current", "Callouts": [ 1329 { 1330 "CalloutList": [ 1331 { "Priority": "medium", "LocCode": "P1" }, 1332 { "Priority": "medium", "LocCode": "P2" }, 1333 { "Priority": "medium", "LocCode": "P3" }, 1334 { "Priority": "low", "LocCode": "P0" } 1335 ] 1336 } 1337 ] 1338 }, 1339 { 1340 "ADValue": "12.0VN", "Callouts": [ 1341 { 1342 "CalloutList": [ 1343 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1344 ] 1345 } 1346 ] 1347 }, 1348 { 1349 "ADValue": "12.0VP", "Callouts": [ 1350 { 1351 "CalloutList": [ 1352 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1353 ] 1354 } 1355 ] 1356 }, 1357 { 1358 "ADValue": "12.0VQ", "Callouts": [ 1359 { 1360 "CalloutList": [ 1361 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1362 ] 1363 } 1364 ] 1365 }, 1366 { 1367 "ADValue": "12.0VR", "Callouts": [ 1368 { 1369 "CalloutList": [ 1370 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1371 ] 1372 } 1373 ] 1374 }, 1375 { 1376 "ADValue": "ThermalDiode1", "Callouts": [ 1377 { 1378 "CalloutList": [ 1379 { "Priority": "high", "LocCode": "P0" } 1380 ] 1381 } 1382 ] 1383 }, 1384 { 1385 "ADValue": "ThermalDiode2", "Callouts": [ 1386 { 1387 "CalloutList": [ 1388 { "Priority": "high", "LocCode": "P0" } 1389 ] 1390 } 1391 ] 1392 }, 1393 { 1394 "ADValue": "ThermalDiode3", "Callouts": [ 1395 { 1396 "CalloutList": [ 1397 { "Priority": "high", "LocCode": "P0" } 1398 ] 1399 } 1400 ] 1401 }, 1402 { 1403 "ADValue": "ThermalDiode4", "Callouts": [ 1404 { 1405 "CalloutList": [ 1406 { "Priority": "high", "LocCode": "P0" } 1407 ] 1408 } 1409 ] 1410 } 1411 ] 1412 }, 1413 1414 "Documentation": { 1415 "Description": "The power sequencer chip detected a voltage fault", 1416 "Message": "The power sequencer chip detected a voltage fault", 1417 "Notes": [ 1418 ] 1419 } 1420 }, 1421 1422 { 1423 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 1424 "Subsystem": "power", 1425 "ComponentID": "0x2700", 1426 1427 "SRC": { 1428 "Type": "11", 1429 "ReasonCode": "0x2900", 1430 "Words6To9": {} 1431 }, 1432 1433 "Documentation": { 1434 "Description": "A write verification error occurred on a device", 1435 "Message": "A write verification error occurred on a device", 1436 "Notes": [ 1437 "This error occurs when a device register is written, ", 1438 "read back, and the two values do not match. This is ", 1439 "also called a read-back error. The device should be ", 1440 "identified using the CALLOUT_DEVICE_PATH or ", 1441 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 1442 "AdditionalData property of the event log. This will ", 1443 "cause the device and the hardware in the communication ", 1444 "path to be called out." 1445 ] 1446 } 1447 }, 1448 1449 { 1450 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 1451 "Subsystem": "power", 1452 "ComponentID": "0x2700", 1453 1454 "SRC": { 1455 "Type": "11", 1456 "ReasonCode": "0xA013", 1457 "Words6To9": {} 1458 }, 1459 1460 "Callouts": [ 1461 { 1462 "CalloutList": [ 1463 { "Priority": "high", "Procedure": "bmc_code" } 1464 ] 1465 } 1466 ], 1467 1468 "Documentation": { 1469 "Description": "A regulators configuration file error occurred", 1470 "Message": "A regulators configuration file error occurred", 1471 "Notes": [ 1472 "The regulators configuration file could not be found, ", 1473 "could not be read, or had invalid contents." 1474 ] 1475 } 1476 }, 1477 1478 { 1479 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 1480 "Subsystem": "power", 1481 "Severity": "critical_system_term", 1482 "ComponentID": "0x2700", 1483 1484 "SRC": { 1485 "Type": "11", 1486 "ReasonCode": "0xA014", 1487 "Words6To9": {}, 1488 "PowerFault": true 1489 }, 1490 1491 "Callouts": [ 1492 { 1493 "CalloutList": [ 1494 { "Priority": "high", "Procedure": "bmc_code" } 1495 ] 1496 } 1497 ], 1498 1499 "Documentation": { 1500 "Description": "A critical regulators configuration file error occurred", 1501 "Message": "A critical regulators configuration file error occurred", 1502 "Notes": [ 1503 "The regulators configuration file could not be found, ", 1504 "could not be read, or had invalid contents. As a result ", 1505 "voltage regulators could not be configured, and the ", 1506 "chassis could not be powered on." 1507 ] 1508 } 1509 }, 1510 1511 { 1512 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 1513 "Subsystem": "power_sequencer", 1514 "ComponentID": "0x2700", 1515 1516 "SRC": { 1517 "Type": "11", 1518 "ReasonCode": "0xD000", 1519 "Words6To9": {} 1520 }, 1521 1522 "Callouts": [ 1523 { 1524 "CalloutList": [ 1525 { "Priority": "high", "LocCode": "P0" } 1526 ] 1527 } 1528 ], 1529 1530 "Documentation": { 1531 "Description": "The power sequencer chip detected a fault", 1532 "Message": "The power sequencer chip detected a fault", 1533 "Notes": [ 1534 ] 1535 } 1536 }, 1537 1538 { 1539 "Name": "xyz.openbmc_project.Power.Error.PowerOnFailure", 1540 "Subsystem": "power_sequencer", 1541 "ComponentID": "0x2700", 1542 1543 "SRC": { 1544 "Type": "11", 1545 "ReasonCode": "0xD002", 1546 "Words6To9": {} 1547 }, 1548 1549 "Callouts": [ 1550 { 1551 "CalloutList": [ 1552 { "Priority": "high", "LocCode": "P0" } 1553 ] 1554 } 1555 ], 1556 1557 "Documentation": { 1558 "Description": "System power failed to turn on", 1559 "Message": "System power failed to turn on", 1560 "Notes": [ 1561 ] 1562 } 1563 }, 1564 1565 { 1566 "Name": "xyz.openbmc_project.Power.Error.Internal", 1567 "Subsystem": "power", 1568 "ComponentID": "0x2700", 1569 1570 "SRC": { 1571 "Type": "11", 1572 "ReasonCode": "0xE000", 1573 "Words6To9": {} 1574 }, 1575 1576 "Callouts": [ 1577 { 1578 "CalloutList": [ 1579 { "Priority": "high", "Procedure": "bmc_code" } 1580 ] 1581 } 1582 ], 1583 1584 "Documentation": { 1585 "Description": "An internal firmware error occurred", 1586 "Message": "An internal firmware error occurred", 1587 "Notes": [ 1588 "The error details must be provided in the AdditionalData ", 1589 "property of the event log." 1590 ] 1591 } 1592 }, 1593 1594 { 1595 "Name": "xyz.openbmc_project.Power.Error.I2C", 1596 "Subsystem": "cec_i2c", 1597 "ComponentID": "0x2700", 1598 1599 "SRC": { 1600 "Type": "11", 1601 "ReasonCode": "0xE100", 1602 "Words6To9": {} 1603 }, 1604 1605 "Documentation": { 1606 "Description": "An I2C error occurred communicating with a device", 1607 "Message": "An I2C error occurred communicating with a device", 1608 "Notes": [ 1609 "The device should be identified using the ", 1610 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 1611 "keywords in the AdditionalData property of the event ", 1612 "log. This will cause the device and the hardware in the ", 1613 "communication path to be called out." 1614 ] 1615 } 1616 }, 1617 1618 { 1619 "Name": "xyz.openbmc_project.Power.Error.PMBus", 1620 "Subsystem": "power", 1621 "ComponentID": "0x2700", 1622 1623 "SRC": { 1624 "Type": "11", 1625 "ReasonCode": "0xE200", 1626 "Words6To9": {} 1627 }, 1628 1629 "Documentation": { 1630 "Description": "A PMBus error occurred on a device", 1631 "Message": "A PMBus error occurred on a device", 1632 "Notes": [ 1633 "This error occurs when the I2C communication was ", 1634 "successful, but the PMBus value read is invalid or ", 1635 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 1636 "in the AdditionalData property of the event log so that ", 1637 "the device is called out but not the communication path." 1638 ] 1639 } 1640 }, 1641 1642 { 1643 "Name": "xyz.openbmc_project.Power.Error.DBus", 1644 "Subsystem": "power", 1645 "ComponentID": "0x2700", 1646 1647 "SRC": { 1648 "Type": "11", 1649 "ReasonCode": "0xE300", 1650 "Words6To9": {} 1651 }, 1652 1653 "Callouts": [ 1654 { 1655 "CalloutList": [ 1656 { "Priority": "high", "Procedure": "bmc_code" } 1657 ] 1658 } 1659 ], 1660 1661 "Documentation": { 1662 "Description": "A firmware inter-process communication (D-Bus) error occurred", 1663 "Message": "A firmware inter-process communication (D-Bus) error occurred" 1664 } 1665 }, 1666 1667 { 1668 "Name": "xyz.openbmc_project.Fan.Error.Fault", 1669 "Subsystem": "power_fans", 1670 "ComponentID": "0x2800", 1671 1672 "SRC": { 1673 "Type": "11", 1674 "ReasonCode": "0x76F0", 1675 "Words6To9": {} 1676 }, 1677 1678 "Documentation": { 1679 "Description": "Fan rotor fault", 1680 "Message": "Fan rotor fault", 1681 "Notes": [ 1682 "This error occurs when a fan rotor has been faulted for a ", 1683 "certain amount of time. The callout is the fan which is ", 1684 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 1685 "passed in during creation and will be either informational ", 1686 "or unrecoverable. The action flags use the defaults and ", 1687 "vary based on the severity." 1688 ] 1689 } 1690 }, 1691 1692 { 1693 "Name": "xyz.openbmc_project.Fan.Error.Missing", 1694 "Subsystem": "power_fans", 1695 "ComponentID": "0x2800", 1696 "Severity": "unrecoverable_redundancy_loss", 1697 "ActionFlags": ["service_action", "report", "call_home"], 1698 1699 "SRC": { 1700 "Type": "11", 1701 "ReasonCode": "0x76F1", 1702 "Words6To9": {} 1703 }, 1704 1705 "Callouts": [ 1706 { 1707 "System": "ibm,rainier", 1708 "CalloutList": [ 1709 { 1710 "Priority": "high", 1711 "SymbolicFRUTrusted": "air_mover", 1712 "UseInventoryLocCode": true 1713 }, 1714 { 1715 "Priority": "low", 1716 "LocCode": "P0" 1717 } 1718 ] 1719 }, 1720 { 1721 "System": "ibm,everest", 1722 "CalloutList": [ 1723 { 1724 "Priority": "high", 1725 "SymbolicFRUTrusted": "air_mover", 1726 "UseInventoryLocCode": true 1727 }, 1728 { 1729 "Priority": "low", 1730 "LocCode": "P1" 1731 } 1732 ] 1733 } 1734 ], 1735 1736 "Documentation": { 1737 "Description": "A fan is missing", 1738 "Message": "A fan is missing", 1739 "Notes": [ 1740 "This error occurs when a fan has been missing for a ", 1741 "certain amount of time. The first callout is the ", 1742 "symbolic FRU AIR_MOVR that has the trusted fan location ", 1743 "code, which it gets using the passed in ", 1744 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 1745 "where the controller and GPIO expander are." 1746 ] 1747 } 1748 }, 1749 1750 { 1751 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 1752 "ComponentID": "0x2800", 1753 "Subsystem": "power_fans", 1754 "Severity": "non_error", 1755 "ActionFlags": ["report"], 1756 "MfgSeverity": "predictive", 1757 "MfgActionFlags": ["service_action", "report"], 1758 1759 "SRC": { 1760 "Type": "11", 1761 "ReasonCode": "0x76F2", 1762 "Words6To9": {} 1763 }, 1764 1765 "Callouts": [ 1766 { 1767 "System": "ibm,rainier", 1768 "CalloutList": [ 1769 {"Priority": "medium", "LocCode": "P0"} 1770 ] 1771 }, 1772 { 1773 "System": "ibm,everest", 1774 "CalloutList": [ 1775 {"Priority": "medium", "LocCode": "P1"} 1776 ] 1777 } 1778 ], 1779 1780 "Documentation": { 1781 "Description": "Presence detect methods for the same fan disagree", 1782 "Message": "Presence detect methods for the same fan disagree", 1783 "Notes": [ 1784 "This error occurs when there is more than one way to detect", 1785 "fan presence, and they don't all agree. For example, the", 1786 "GPIO says a fan isn't present, but the tach readings are", 1787 "nonzero. This is informational, unless in manufacturing.", 1788 "The fan FRU is passed in as a high priority callout.", 1789 "The FRU the GPIO source is on is called out medium." 1790 ] 1791 } 1792 }, 1793 1794 { 1795 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 1796 "ComponentID": "0x2800", 1797 "Subsystem": "power_fans", 1798 "Severity": "critical_system_term", 1799 "ActionFlags": ["service_action", "report", "call_home"], 1800 1801 "SRC": { 1802 "Type": "11", 1803 "ReasonCode": "0x76F3", 1804 "Words6To9": {}, 1805 "PowerFault": true 1806 }, 1807 1808 "Callouts": [ 1809 { 1810 "System": "ibm,rainier", 1811 "CalloutList": [ 1812 {"Priority": "high", "LocCode": "P0-C5"}, 1813 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 1814 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 1815 {"Priority": "low", "LocCode": "P0"} 1816 ] 1817 }, 1818 { 1819 "System": "ibm,everest", 1820 "CalloutList": [ 1821 {"Priority": "high", "LocCode": "P0-C0"}, 1822 {"Priority": "medium", "LocCode": "P1"}, 1823 {"Priority": "low", "LocCode": "P0"} 1824 ] 1825 } 1826 ], 1827 1828 "Documentation": { 1829 "Description": "The fan controller device is offline", 1830 "Message": "The fan controller is offline. The system must be powered off.", 1831 "Notes": [ 1832 "The device that controls the fans is offline so the fan", 1833 "targets and speeds are unknown. The system will be shut", 1834 "down to preserve thermal safety. There may be an I2C", 1835 "or power problem with the device." 1836 ] 1837 } 1838 }, 1839 1840 { 1841 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 1842 "Subsystem": "power_fans", 1843 "ComponentID": "0x2800", 1844 "Severity": "unrecoverable_redundancy_loss", 1845 "ActionFlags": ["service_action", "report", "call_home"], 1846 1847 "SRC": { 1848 "Type": "11", 1849 "ReasonCode": "0x76F4", 1850 "Words6To9": {} 1851 }, 1852 1853 "Callouts": [ 1854 { 1855 "System" : "ibm,rainier", 1856 "CalloutList": [ 1857 {"Priority": "high", "LocCode": "P0-C5"}, 1858 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 1859 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 1860 {"Priority": "low", "LocCode": "P0"} 1861 ] 1862 }, 1863 { 1864 "System" : "ibm,everest", 1865 "CalloutList": [ 1866 {"Priority": "high", "LocCode": "P0-C0"}, 1867 {"Priority": "medium", "LocCode": "P1"}, 1868 {"Priority": "low", "LocCode": "P0"} 1869 ] 1870 } 1871 ], 1872 1873 "Documentation": { 1874 "Description": "Fan GPIO sensors not present", 1875 "Message": "Fan GPIO sensors not present", 1876 "Notes": [ 1877 "The device that reports fan presence is not functioning." 1878 ] 1879 } 1880 }, 1881 1882 { 1883 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 1884 "Subsystem": "power", 1885 "ComponentID": "0x2800", 1886 "Severity": "predictive", 1887 "ActionFlags": ["service_action", "report"], 1888 1889 "SRC": { 1890 "ReasonCode": "0x2801", 1891 "Words6To9": {} 1892 }, 1893 1894 "CalloutsUsingAD": { 1895 "ADName": "SENSOR_NAME", 1896 "CalloutsWithTheirADValues": [ 1897 { 1898 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 1899 "Callouts": [ 1900 { 1901 "CalloutList": [ 1902 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 1903 ] 1904 } 1905 ] 1906 } 1907 ] 1908 }, 1909 1910 "Documentation": { 1911 "Description": "A temperature sensor exceeded its performance loss threshold.", 1912 "Message": "A temperature sensor exceeded its performance loss threshold.", 1913 "Notes": [ 1914 "A temperature sensor crossed its performance loss threshold value", 1915 "If it is the ambient sensor, then a symbolic FRU will be added.", 1916 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 1917 "a FRU callout." 1918 ] 1919 } 1920 }, 1921 1922 { 1923 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 1924 "Subsystem": "power", 1925 "ComponentID": "0x2800", 1926 "Severity": "non_error", 1927 "ActionFlags": ["report"], 1928 "EventType": "env_normal", 1929 1930 "SRC": { 1931 "ReasonCode": "0x2802", 1932 "Words6To9": {} 1933 }, 1934 1935 "CalloutsUsingAD": { 1936 "ADName": "SENSOR_NAME", 1937 "CalloutsWithTheirADValues": [ 1938 { 1939 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 1940 "Callouts": [ 1941 { 1942 "CalloutList": [ 1943 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 1944 ] 1945 } 1946 ] 1947 } 1948 ] 1949 }, 1950 1951 "Documentation": { 1952 "Description": "A temperature sensor is under its performance loss threshold.", 1953 "Message": "A temperature sensor is under its performance loss threshold.", 1954 "Notes": [ 1955 "A temperature sensor crossed under its performance loss threshold value", 1956 "If it is the ambient sensor, then a symbolic FRU will be added." 1957 ] 1958 } 1959 }, 1960 1961 { 1962 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 1963 "Subsystem": "power", 1964 "ComponentID": "0x2800", 1965 "Severity": "predictive", 1966 "ActionFlags": ["service_action", "report"], 1967 1968 "SRC": { 1969 "ReasonCode": "0x2803", 1970 "Words6To9": {} 1971 }, 1972 1973 "CalloutsUsingAD": { 1974 "ADName": "SENSOR_NAME", 1975 "CalloutsWithTheirADValues": [ 1976 { 1977 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 1978 "Callouts": [ 1979 { 1980 "CalloutList": [ 1981 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 1982 ] 1983 } 1984 ] 1985 } 1986 ] 1987 }, 1988 1989 "Documentation": { 1990 "Description": "A temperature sensor exceeded its warning threshold.", 1991 "Message": "A temperature sensor exceeded its warning threshold.", 1992 "Notes": [ 1993 "A temperature sensor crossed its warning threshold value", 1994 "If it is the ambient sensor, then a symbolic FRU will be added.", 1995 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 1996 "a FRU callout." 1997 ] 1998 } 1999 }, 2000 2001 { 2002 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 2003 "Subsystem": "power", 2004 "ComponentID": "0x2800", 2005 "Severity": "non_error", 2006 "ActionFlags": ["report"], 2007 "EventType": "env_normal", 2008 2009 "SRC": { 2010 "ReasonCode": "0x2804", 2011 "Words6To9": {} 2012 }, 2013 2014 "CalloutsUsingAD": { 2015 "ADName": "SENSOR_NAME", 2016 "CalloutsWithTheirADValues": [ 2017 { 2018 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2019 "Callouts": [ 2020 { 2021 "CalloutList": [ 2022 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2023 ] 2024 } 2025 ] 2026 } 2027 ] 2028 }, 2029 2030 "Documentation": { 2031 "Description": "A temperature sensor is under its warning threshold.", 2032 "Message": "A temperature sensor is under its warning threshold.", 2033 "Notes": [ 2034 "A temperature sensor crossed under its warning threshold value", 2035 "If it is the ambient sensor, then a symbolic FRU will be added." 2036 ] 2037 } 2038 }, 2039 2040 { 2041 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 2042 "Subsystem": "power", 2043 "ComponentID": "0x2800", 2044 "Severity": "predictive", 2045 "ActionFlags": ["service_action", "report"], 2046 2047 "SRC": { 2048 "ReasonCode": "0x2805", 2049 "Words6To9": {} 2050 }, 2051 2052 "CalloutsUsingAD": { 2053 "ADName": "SENSOR_NAME", 2054 "CalloutsWithTheirADValues": [ 2055 { 2056 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2057 "Callouts": [ 2058 { 2059 "CalloutList": [ 2060 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2061 ] 2062 } 2063 ] 2064 } 2065 ] 2066 }, 2067 2068 "Documentation": { 2069 "Description": "A temperature sensor exceeded its critical threshold.", 2070 "Message": "A temperature sensor exceeded its critical threshold.", 2071 "Notes": [ 2072 "A temperature sensor crossed its critical threshold value", 2073 "If it is the ambient sensor, then a symbolic FRU will be added.", 2074 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2075 "a FRU callout." 2076 ] 2077 } 2078 }, 2079 2080 { 2081 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 2082 "Subsystem": "power", 2083 "ComponentID": "0x2800", 2084 "Severity": "non_error", 2085 "ActionFlags": ["report"], 2086 "EventType": "env_normal", 2087 2088 "SRC": { 2089 "ReasonCode": "0x2806", 2090 "Words6To9": {} 2091 }, 2092 2093 "CalloutsUsingAD": { 2094 "ADName": "SENSOR_NAME", 2095 "CalloutsWithTheirADValues": [ 2096 { 2097 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2098 "Callouts": [ 2099 { 2100 "CalloutList": [ 2101 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2102 ] 2103 } 2104 ] 2105 } 2106 ] 2107 }, 2108 2109 "Documentation": { 2110 "Description": "A temperature sensor is under its critical threshold.", 2111 "Message": "A temperature sensor is under its critical threshold.", 2112 "Notes": [ 2113 "A temperature sensor crossed under its critical threshold value", 2114 "If it is the ambient sensor, then a symbolic FRU will be added." 2115 ] 2116 } 2117 }, 2118 2119 { 2120 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 2121 "Subsystem": "power", 2122 "ComponentID": "0x2800", 2123 "Severity": "predictive", 2124 "ActionFlags": ["service_action", "report"], 2125 2126 "SRC": { 2127 "ReasonCode": "0x2807", 2128 "Words6To9": {} 2129 }, 2130 2131 "Callouts": [ 2132 { 2133 "CalloutList": [ 2134 { 2135 "Priority": "high", 2136 "SymbolicFRU": "ambient_temp" 2137 } 2138 ] 2139 } 2140 ], 2141 2142 "Documentation": { 2143 "Description": "The ambient temperature passed the EPOW3 limit.", 2144 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 2145 "Notes": [ 2146 "This error occurs when the ambient temperature surpassed", 2147 "the EPOW3 shutdown limit." 2148 ] 2149 } 2150 }, 2151 2152 { 2153 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 2154 "Subsystem": "power", 2155 "ComponentID": "0x2800", 2156 "Severity": "non_error", 2157 "ActionFlags": ["report"], 2158 "EventType": "env_normal", 2159 2160 "SRC": { 2161 "ReasonCode": "0x2808", 2162 "Words6To9": {} 2163 }, 2164 2165 "Callouts": [ 2166 { 2167 "CalloutList": [ 2168 { 2169 "Priority": "high", 2170 "SymbolicFRU": "ambient_temp_back" 2171 } 2172 ] 2173 } 2174 ], 2175 2176 "Documentation": { 2177 "Description": "The ambient temperature is back under the EPOW3 limit.", 2178 "Message": "The ambient temperature is back under the EPOW3 limit." 2179 } 2180 }, 2181 2182 { 2183 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 2184 "Subsystem": "power", 2185 "ComponentID": "0x2800", 2186 "ActionFlags": ["service_action", "report"], 2187 2188 "SRC": { 2189 "ReasonCode": "0x2809", 2190 "Words6To9": {} 2191 }, 2192 2193 "Callouts": [ 2194 { 2195 "CalloutList": [ 2196 { 2197 "Priority": "high", 2198 "SymbolicFRU": "ambient_temp" 2199 } 2200 ] 2201 } 2202 ], 2203 2204 "Documentation": { 2205 "Description": "The ambient temperature passed the EPOW4 limit.", 2206 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 2207 "Notes": [ 2208 "This error occurs when the ambient temperature surpassed", 2209 "the EPOW4 shutdown limit." 2210 ] 2211 } 2212 }, 2213 2214 { 2215 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 2216 "Subsystem": "cec_vpd", 2217 "ComponentID": "0x4000", 2218 2219 "SRC": { 2220 "ReasonCode": "0x4000", 2221 "Words6To9": 2222 { 2223 "6": 2224 { 2225 "Description": "Errno of the failure.", 2226 "AdditionalDataPropSource": "CALLOUT_ERRNO" 2227 } 2228 } 2229 }, 2230 2231 "Documentation": { 2232 "Description": "A path access error ocurred", 2233 "Message": "An EEPROM path access error occurred.", 2234 "Notes": [ 2235 "This error occurs when parser is unable to access", 2236 "EEPROM path. Errno and device path are captured as", 2237 "additional data." 2238 ] 2239 } 2240 }, 2241 2242 { 2243 "Name": "com.ibm.VPD.Error.InvalidVPD", 2244 "Subsystem": "cec_vpd", 2245 "ComponentID": "0x4000", 2246 2247 "SRC": { 2248 "ReasonCode": "0x4001", 2249 "Words6To9": 2250 { 2251 } 2252 }, 2253 2254 "Documentation": { 2255 "Description": "Invalid VPD data.", 2256 "Message": "A VPD data exception occurred.", 2257 "Notes": [ 2258 "This error occurs when VPD data is found to be", 2259 "invalid. This can be when VPD file is missing out", 2260 "mandatory records.Inventory path is captured in", 2261 "additional data." 2262 ] 2263 } 2264 }, 2265 2266 { 2267 "Name": "com.ibm.VPD.Error.EccCheckFailed", 2268 "Subsystem": "cec_vpd", 2269 "ComponentID": "0x4000", 2270 2271 "SRC": { 2272 "ReasonCode": "0x4002", 2273 "Words6To9": 2274 { 2275 } 2276 }, 2277 2278 "Documentation": { 2279 "Description": "Invalid VPD ecc data.", 2280 "Message": "A VPD ecc exception occurred.", 2281 "Notes": [ 2282 "This error occurs when VPD ecc check fails for the FRU.", 2283 "Inventory path for the failed FRU is captured in additonal", 2284 "data." 2285 ] 2286 } 2287 }, 2288 2289 { 2290 "Name": "com.ibm.VPD.Error.InvalidJson", 2291 "Subsystem": "cec_vpd", 2292 "ComponentID": "0x4000", 2293 2294 "SRC": { 2295 "ReasonCode": "0x4003", 2296 "Words6To9": 2297 { 2298 } 2299 }, 2300 2301 "Documentation": { 2302 "Description": "Invalid Json", 2303 "Message": "A Json failure occurred.", 2304 "Notes": [ 2305 "This error occurs when parser fails to access", 2306 "Json file or there is any issue with Json data.", 2307 "Failed Json path and cause of failure is captured", 2308 "in additional data." 2309 ] 2310 } 2311 }, 2312 2313 { 2314 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 2315 "Subsystem": "cec_vpd", 2316 "ComponentID": "0x4000", 2317 2318 "SRC": { 2319 "ReasonCode": "0x4004", 2320 "Words6To9": 2321 { 2322 } 2323 }, 2324 2325 "Documentation": { 2326 "Description": "System VPD restore failed", 2327 "Message": "A system VPD restoration error occurred.", 2328 "Notes": [ 2329 "This error occurs when restoring of system VPD fails.", 2330 "The FRU path and reason for failure is captured in", 2331 "additional data." 2332 ] 2333 } 2334 }, 2335 2336 { 2337 "Name": "com.ibm.VPD.Error.DbusFailure", 2338 "Subsystem": "cec_vpd", 2339 "ComponentID": "0x4000", 2340 2341 "SRC": { 2342 "ReasonCode": "0x4005", 2343 "Words6To9": 2344 { 2345 } 2346 }, 2347 2348 "Documentation": { 2349 "Description": "Dbus exception", 2350 "Message": "A Dbus internal error occurred.", 2351 "Notes": [ 2352 "This error occurs when Dbus operation fails.", 2353 "Exceptions details are captured in additonal", 2354 "data." 2355 ] 2356 } 2357 }, 2358 2359 { 2360 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 2361 "Subsystem": "cec_sp_hostboot_iface", 2362 2363 "SRC": 2364 { 2365 "ReasonCode": "0xC101", 2366 "Words6To9": 2367 { 2368 } 2369 }, 2370 2371 "Documentation": 2372 { 2373 "Description": "Host did not respond within the watchdog timeout interval", 2374 "Message": "Host did not respond before the watchdog timeout interval expired", 2375 "Notes": [ 2376 "Host did not respond before the expiry of the watchdog timeout interval.", 2377 "Collecting hostboot dump." 2378 ] 2379 } 2380 } 2381 2382 ] 2383} 2384