1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 8 "SRC": 9 { 10 "ReasonCode": "0x1001", 11 "Words6To9": 12 { 13 "6": 14 { 15 "Description": "Timeout in ms", 16 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 17 } 18 } 19 }, 20 21 "Documentation": 22 { 23 "Description": "This is a generic timeout error", 24 "Message": "An operation timed out", 25 "Notes": [ 26 "The journal should contain more information" 27 ] 28 } 29 }, 30 31 { 32 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 33 "Subsystem": "bmc_firmware", 34 35 "SRC": 36 { 37 "ReasonCode": "0x1002", 38 "Words6To9": 39 { 40 } 41 }, 42 43 "Documentation": 44 { 45 "Description": "BMC code had a generic internal failure", 46 "Message": "An application had an internal failure", 47 "Notes": [ 48 "The journal should contain more information" 49 ] 50 } 51 }, 52 53 { 54 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 55 "Subsystem": "user_error", 56 57 "SRC": 58 { 59 "ReasonCode": "0x1003", 60 "Words6To9": 61 { 62 } 63 }, 64 65 "Documentation": 66 { 67 "Description": "BMC code was given an invalid argument", 68 "Message": "Code was given an invalid argument", 69 "Notes": [ 70 "The journal should contain more information" 71 ] 72 } 73 }, 74 { 75 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 76 "Subsystem": "user_error", 77 78 "SRC": 79 { 80 "ReasonCode": "0x1004", 81 "Words6To9": 82 { 83 } 84 }, 85 86 "Documentation": 87 { 88 "Description": "An operation failed due to insufficient permission", 89 "Message": "An operation failed due to unsufficient permission", 90 "Notes": [ 91 "The journal should contain more information" 92 ] 93 } 94 }, 95 96 { 97 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 98 "Subsystem": "user_error", 99 100 "SRC": 101 { 102 "ReasonCode": "0x1005", 103 "Words6To9": 104 { 105 } 106 }, 107 108 "Documentation": 109 { 110 "Description": "An operation failed because it isn't allowed", 111 "Message": "An operation failed because it isn't allowed", 112 "Notes": [ 113 "The journal should contain more information" 114 ] 115 } 116 }, 117 118 { 119 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 120 "Subsystem": "user_error", 121 122 "SRC": 123 { 124 "ReasonCode": "0x1006", 125 "Words6To9": 126 { 127 } 128 }, 129 130 "Documentation": 131 { 132 "Description": "The server's CA certificate has not been provided", 133 "Message": "The server's CA certificate has not been provided" 134 } 135 }, 136 137 { 138 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 139 "Subsystem": "cec_chip_iface", 140 141 "SRC": 142 { 143 "ReasonCode": "0x1007", 144 "Words6To9": 145 { 146 "6": 147 { 148 "Description": "errno of the failure", 149 "AdditionalDataPropSource": "CALLOUT_ERRNO" 150 } 151 } 152 }, 153 154 "Documentation": 155 { 156 "Description": "Sensor device read failure", 157 "Message": "There was a failure when reading a sensor device", 158 "Notes": [ 159 "The severity is set by the creator.", 160 "The action flags are set automatically by the code.", 161 "Callouts added based on CALLOUT_DEVICE_PATH." 162 ] 163 } 164 }, 165 166 { 167 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 168 "Subsystem": "cec_chip_iface", 169 170 "SRC": 171 { 172 "ReasonCode": "0x1008", 173 "Words6To9": 174 { 175 "6": 176 { 177 "Description": "errno of the failure", 178 "AdditionalDataPropSource": "CALLOUT_ERRNO" 179 } 180 } 181 }, 182 183 "Documentation": 184 { 185 "Description": "Device read failure", 186 "Message": "There was a failure when reading a hardware device", 187 "Notes": [ 188 "The severity is set by the creator.", 189 "The action flags are set automatically by the code.", 190 "Callouts added based on CALLOUT_DEVICE_PATH." 191 ] 192 } 193 }, 194 195 { 196 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 197 "Subsystem": "cec_chip_iface", 198 199 "SRC": 200 { 201 "ReasonCode": "0x1009", 202 "Words6To9": 203 { 204 "6": 205 { 206 "Description": "errno of the failure", 207 "AdditionalDataPropSource": "CALLOUT_ERRNO" 208 } 209 } 210 }, 211 212 "Documentation": 213 { 214 "Description": "Device write failure", 215 "Message": "There was a failure when writing to a hardware device", 216 "Notes": [ 217 "The severity is set by the creator.", 218 "The action flags are set automatically by the code.", 219 "Callouts added based on CALLOUT_DEVICE_PATH" 220 ] 221 } 222 }, 223 224 { 225 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 226 "Subsystem": "cec_chip_iface", 227 228 "SRC": 229 { 230 "ReasonCode": "0x100A", 231 "Words6To9": 232 { 233 "6": 234 { 235 "Description": "errno of the failure", 236 "AdditionalDataPropSource": "CALLOUT_ERRNO" 237 } 238 } 239 }, 240 241 "Documentation": 242 { 243 "Description": "Device write failure", 244 "Message": "There was a failure when writing to a hardware device", 245 "Notes": [ 246 "The severity is set by the creator.", 247 "The action flags are set automatically by the code.", 248 "Callouts added based on CALLOUT_DEVICE_PATH" 249 ] 250 } 251 }, 252 253 { 254 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 255 "Subsystem": "bmc_firmware", 256 "Severity": "non_error", 257 258 "SRC": 259 { 260 "ReasonCode": "0x2001", 261 "Words6To9": 262 { 263 "6": 264 { 265 "Description": "The bad PEL ID", 266 "AdditionalDataPropSource": "BAD_ID" 267 } 268 } 269 }, 270 271 "Documentation": 272 { 273 "Description": "The BMC sent the host a malformed PEL", 274 "Message": "The BMC sent the host a malformed PEL", 275 "Notes": [ 276 "The host firmware rejected that PEL." 277 ] 278 } 279 }, 280 281 { 282 "Name": "org.open_power.Logging.Error.BadHostPEL", 283 "Subsystem": "platform_firmware", 284 "Severity": "unrecoverable", 285 286 "SRC": 287 { 288 "ReasonCode": "0x2002", 289 "Words6To9": 290 { 291 "6": 292 { 293 "Description": "The PLID of the invalid PEL", 294 "AdditionalDataPropSource": "PLID" 295 }, 296 "7": 297 { 298 "Description": "The corresponding OpenBMC event log ID", 299 "AdditionalDataPropSource": "OBMC_LOG_ID" 300 }, 301 "8": 302 { 303 "Description": "The size of the invalid PEL", 304 "AdditionalDataPropSource": "PEL_SIZE" 305 } 306 } 307 }, 308 309 "Documentation": 310 { 311 "Description": "The host sent the BMC an invalid PEL", 312 "Message": "The host sent the BMC an invalid PEL", 313 "Notes": [ 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.TestError1", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2003", 326 "Words6To9": 327 { 328 } 329 }, 330 331 "Callouts": [ 332 { 333 "CalloutList": [ 334 {"Priority": "high", "Procedure": "bmc_code"}, 335 {"Priority": "medium", "SymbolicFRU": "service_docs"} 336 ] 337 } 338 ], 339 340 "Documentation": 341 { 342 "Description": "An error for testing", 343 "Message": "This is a test error" 344 } 345 }, 346 347 { 348 "Name": "xyz.openbmc_project.Logging.Error.Default", 349 "Subsystem": "other_na", 350 351 "SRC": 352 { 353 "ReasonCode": "0x2004", 354 "Words6To9": 355 { 356 } 357 }, 358 359 "Documentation": 360 { 361 "Description": "This entry is used when no other matching entry is found", 362 "Message": "Unknown (Original event not in message registry)", 363 "Notes": [ 364 "This is used when the actual error name isn't found in ", 365 "the registry. The original error name will be stored ", 366 "in the UserData section that contains the AdditionalData ", 367 "properties using the key ERROR_NAME.", 368 "This error may contain callouts if the creator passed ", 369 "them in.", 370 "The severity is set by the creator.", 371 "If this error is seen, then a code change needs to be ", 372 "made to add the missing error entry to this registry." 373 ] 374 } 375 }, 376 377 { 378 "Name": "org.open_power.PHAL.Error.Boot", 379 "Subsystem": "cec_hardware", 380 "ComponentID": "0x3000", 381 "Severity": "unrecoverable", 382 383 "SRC": 384 { 385 "ReasonCode": "0x3001", 386 "Words6To9": 387 { 388 } 389 }, 390 391 "Documentation": 392 { 393 "Description": "Failure occured during boot process", 394 "Message": "Failure occured during boot process", 395 "Notes": [ 396 "Debug traces will be captured in AdditionalData section" 397 ] 398 } 399 }, 400 401 { 402 "Name": "org.open_power.PHAL.Error.PrePowerOff", 403 "Subsystem": "cec_hardware", 404 "ComponentID": "0x3000", 405 406 "SRC": 407 { 408 "ReasonCode": "0x3002", 409 "Words6To9": 410 { 411 } 412 }, 413 414 "Documentation": 415 { 416 "Description": "Failure occurred during PHAL pre-poweroff operations", 417 "Message": "Failure occurred during PHAL pre-poweroff operations", 418 "Notes": [ 419 "Severity needs to be set based on needs for this registry.", 420 "FFDC (First Failure Data Collection) will be collected ", 421 "and added into PEL." 422 ] 423 } 424 }, 425 426 { 427 "Name": "org.open_power.PHAL.Error.devtreeSync", 428 "Subsystem": "cec_hardware", 429 "ComponentID": "0x3000", 430 "Severity": "unrecoverable", 431 432 "SRC": 433 { 434 "ReasonCode": "0x3003", 435 "Words6To9": 436 { 437 } 438 }, 439 440 "Documentation": 441 { 442 "Description": "Failure occurred during PHAL devtree sync ", 443 "Message": "Failure occurred during PHAL devtree sync", 444 "Notes": [ 445 "The journal should contain more information" 446 ] 447 } 448 }, 449 450 { 451 "Name": "org.open_power.PHAL.Error.devtreeBackup", 452 "Subsystem": "cec_hardware", 453 "ComponentID": "0x3000", 454 "Severity": "unrecoverable", 455 456 "SRC": 457 { 458 "ReasonCode": "0x3004", 459 "Words6To9": 460 { 461 } 462 }, 463 464 "Documentation": 465 { 466 "Description": "Failure occurred during PHAL devtree backup ", 467 "Message": "Failure occurred during PHAL devtree backup", 468 "Notes": [ 469 "The journal should contain more information" 470 ] 471 } 472 }, 473 474 { 475 "Name": "org.open_power.PHAL.Error.HostRunning", 476 "Subsystem": "cec_sp_hostboot_iface", 477 "ComponentID": "0x3000", 478 479 "SRC": 480 { 481 "ReasonCode": "0x3005", 482 "Words6To9": 483 { 484 } 485 }, 486 487 "Documentation": 488 { 489 "Description": "Host did not respond to BMC after a BMC reset", 490 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 491 "Notes": [ 492 "System will be left in its current state to ensure host ", 493 "is not unexpectedly taken down. There is most likely an ", 494 "issue in the software or hardware communication path ", 495 "between the BMC and the Host firmware.", 496 "A BMC dump will be collected with relevant FFDC." 497 ] 498 } 499 }, 500 501 { 502 "Name": "org.open_power.PHAL.Error.devtreeReinit", 503 "Subsystem": "cec_hardware", 504 "ComponentID": "0x3000", 505 "Severity": "unrecoverable", 506 507 "SRC": 508 { 509 "ReasonCode": "0x3006", 510 "Words6To9": 511 { 512 } 513 }, 514 515 "Documentation": 516 { 517 "Description": "Failure re-initializing BMC to Host data structure", 518 "Message": "Failure occurred during re-initializing BMC to Host data structure", 519 "Notes": [ 520 "The journal should contain more information" 521 ] 522 } 523 }, 524 525 { 526 "Name": "org.open_power.HardwareIsolation.Error", 527 "Subsystem": "cec_hardware", 528 "ComponentID": "0x3100", 529 530 "SRC": 531 { 532 "ReasonCode": "0x3101", 533 "Words6To9": 534 { 535 } 536 }, 537 538 "Documentation": 539 { 540 "Description": "Failure occured during hardware isolation operations", 541 "Message": "Failure occured during hardware isolation operations", 542 "Notes": [ 543 "Severity needs to be set based on needs for this registry.", 544 "Debug traces will be captured in AdditionalData section" 545 ] 546 } 547 }, 548 549 { 550 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 551 "Subsystem": "cec_sp_hostboot_iface", 552 "ComponentID": "0x3400", 553 "SRC": 554 { 555 "ReasonCode": "0x3401", 556 "Words6To9": 557 { 558 } 559 }, 560 "Documentation": 561 { 562 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 563 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 564 "Notes": [ 565 "System will follow recovery policy, resulting in this ", 566 "error and most likely a a reboot of the host. The issue ", 567 "is most likely the result of the BMC rebooting while the ", 568 "host was booting and in a state where it still needed ", 569 "the BMC to complete its boot." 570 ] 571 } 572 }, 573 574 { 575 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 576 "Subsystem": "processor_chip", 577 "ComponentID": "0x3500", 578 579 "SRC": 580 { 581 "ReasonCode": "0x3500", 582 "Words6To9": 583 { 584 "6": 585 { 586 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 587 "AdditionalDataPropSource": "SRC6" 588 } 589 } 590 }, 591 592 "Documentation": 593 { 594 "Description": "chipop failure with SBE provided FFDC", 595 "Message": "chipop request failure reported by SBE", 596 "Notes": [ 597 "The severity is set by the creator.", 598 "Callouts added based on SBE provided FFDC.", 599 "SBE provided additional debug data included as part of the", 600 "additional user data section." 601 ] 602 } 603 }, 604 605 { 606 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 607 "Subsystem": "processor_chip", 608 "ComponentID": "0x3500", 609 610 "SRC": 611 { 612 "ReasonCode": "0x3501", 613 "Words6To9": 614 { 615 "6": 616 { 617 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 618 "AdditionalDataPropSource": "SRC6" 619 } 620 } 621 }, 622 623 "Documentation": 624 { 625 "Description": "SBE chipop timeout", 626 "Message": "chipop timeout reported during SBE communication", 627 "Notes": [ 628 "The severity is set by the creator.", 629 "Check SBE Dump associated to this error to debug the failure." 630 ] 631 } 632 }, 633 634 { 635 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 636 "Subsystem": "processor_chip", 637 "ComponentID": "0x3500", 638 639 "SRC": 640 { 641 "ReasonCode": "0x3502", 642 "Words6To9": 643 { 644 "6": 645 { 646 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 647 "AdditionalDataPropSource": "SRC6" 648 }, 649 "7": 650 { 651 "Description": "Value of SBE state", 652 "AdditionalDataPropSource": "SRC7" 653 } 654 } 655 }, 656 657 "Documentation": 658 { 659 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 660 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 661 "Notes": [ 662 "The severity is set by the creator." 663 ] 664 } 665 }, 666 667 { 668 "Name": "org.open_power.Processor.Error.SbeBootFailure", 669 "Subsystem": "processor_chip", 670 "ComponentID": "0x3500", 671 672 "SRC": 673 { 674 "ReasonCode": "0x3503", 675 "Words6To9": 676 { 677 "6": 678 { 679 "Description": "[0:15] chip position", 680 "AdditionalDataPropSource": "SRC6" 681 } 682 } 683 }, 684 685 "Documentation": 686 { 687 "Description": "Boot failure with SBE provided FFDC", 688 "Message": "Boot failure reported by SBE", 689 "Notes": [ 690 "The severity is set by the creator.", 691 "Callouts added based on SBE provided FFDC.", 692 "SBE provided additional debug data included as part of the", 693 "additional user data section." 694 ] 695 } 696 }, 697 698 { 699 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 700 "Subsystem": "processor_chip", 701 "ComponentID": "0x3500", 702 703 "SRC": 704 { 705 "ReasonCode": "0x3504", 706 "Words6To9": 707 { 708 } 709 }, 710 711 "Documentation": 712 { 713 "Description": "SBE Boot timeout", 714 "Message": "timeout reported during SBE boot process", 715 "Notes": [ 716 "The severity is set by the creator.", 717 "Check SBE Dump associated to this error to debug the failure." 718 ] 719 } 720 }, 721 722 { 723 "Name": "org.open_power.Attn.Error.Terminate", 724 "Subsystem": "cec_hardware", 725 "Severity": "non_error", 726 727 "SRC": 728 { 729 "ReasonCode": "0xD138", 730 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 731 "Words6To9": 732 { 733 } 734 }, 735 736 "Documentation": 737 { 738 "Description": "Status shows TI special attention active", 739 "Message": "TI special attention detected", 740 "Notes": [ 741 "This entry is for any TI special attention event ", 742 "reported by the attention handler component" 743 ] 744 } 745 }, 746 747 { 748 "Name": "org.open_power.Attn.Error.Fail", 749 "Subsystem": "bmc_firmware", 750 "Severity": "unrecoverable_loss_of_function", 751 752 "SRC": 753 { 754 "ReasonCode": "0xD13E", 755 "Words6To9": 756 { 757 "6": 758 { 759 "Description": "Error code from attention handler", 760 "AdditionalDataPropSource": "ERROR_CODE" 761 } 762 } 763 }, 764 "Documentation": 765 { 766 "Description": "The attention handler encountered an error", 767 "MessageArgSources" : ["SRCWord6"], 768 "Message": "Attention handler error %1", 769 "Notes": [ 770 "Attention handler will provide error code" 771 ] 772 } 773 }, 774 775 { 776 "Name": "org.open_power.Attn.Error.Vital", 777 "Subsystem": "processor_chip", 778 "Severity": "critical", 779 780 "SRC": 781 { 782 "ReasonCode": "0xD16D", 783 "Words6To9": 784 { 785 } 786 }, 787 788 "Documentation": 789 { 790 "Description": "Status shows SBE vital attention active", 791 "Message": "SBE vital attention detected", 792 "Notes": [ 793 "This entry is for any SBE vital attention event ", 794 "reported by the attention handler component" 795 ] 796 } 797 }, 798 799 { 800 "Name": "org.open_power.HwDiags.Error.Checkstop", 801 "Subsystem": "cec_hardware", 802 "ActionFlags": [ "service_action", "report", "call_home" ], 803 804 "SRC": 805 { 806 "ReasonCode": "0xE510", 807 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 808 "Words6To9": 809 { 810 "6": 811 { 812 "AdditionalDataPropSource": "SRC6" 813 }, 814 "7": 815 { 816 "AdditionalDataPropSource": "SRC7" 817 }, 818 "8": 819 { 820 "AdditionalDataPropSource": "SRC8" 821 } 822 } 823 }, 824 825 "Documentation": 826 { 827 "Description": "A system checkstop attention has occurred", 828 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 829 "Message": "Error Signature: %1 %2 %3" 830 } 831 }, 832 833 { 834 "Name": "org.open_power.HwDiags.Error.Predictive", 835 "Subsystem": "cec_hardware", 836 "ActionFlags": [ "service_action", "report", "call_home" ], 837 838 "SRC": 839 { 840 "ReasonCode": "0xE511", 841 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 842 "Words6To9": 843 { 844 "6": 845 { 846 "AdditionalDataPropSource": "SRC6" 847 }, 848 "7": 849 { 850 "AdditionalDataPropSource": "SRC7" 851 }, 852 "8": 853 { 854 "AdditionalDataPropSource": "SRC8" 855 } 856 } 857 }, 858 859 "Documentation": 860 { 861 "Description": "A hardware attention requiring service has occurred", 862 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 863 "Message": "Error Signature: %1 %2 %3" 864 } 865 }, 866 867 { 868 "Name": "org.open_power.HwDiags.Error.Informational", 869 "Subsystem": "cec_hardware", 870 "ActionFlags": [ "hidden", "dont_report" ], 871 872 "SRC": 873 { 874 "ReasonCode": "0xE512", 875 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 876 "Words6To9": 877 { 878 "6": 879 { 880 "AdditionalDataPropSource": "SRC6" 881 }, 882 "7": 883 { 884 "AdditionalDataPropSource": "SRC7" 885 }, 886 "8": 887 { 888 "AdditionalDataPropSource": "SRC8" 889 } 890 } 891 }, 892 893 "Documentation": 894 { 895 "Description": "Manual analysis was initiated via the command line. FFDC only.", 896 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 897 "Message": "Error Signature: %1 %2 %3" 898 } 899 }, 900 901 { 902 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 903 "Subsystem": "power_supply", 904 "Severity": "unrecoverable_redundancy_loss", 905 "ActionFlags": ["service_action", "report"], 906 "ComponentID": "0x2700", 907 908 "SRC": { 909 "Type": "11", 910 "ReasonCode": "0x15F0", 911 "Words6To9": {} 912 }, 913 914 "Callouts": [ 915 { 916 "CalloutList": [ 917 { "Priority": "high", "SymbolicFRU": "pwrsply" } 918 ] 919 } 920 ], 921 922 "Documentation": { 923 "Description": "Power Supply input power fault", 924 "Message": "A power supply has indicated an input or under voltage condition.", 925 "Notes": [ 926 "Check the power supply cabling and/or input power ", 927 "source. The PWRSPLY procedure is used rather than ", 928 "calling out a location code, as typically these faults ", 929 "are related to the supplied power, the cable, or the ", 930 "cable connectors. If the input fault resolves down to an ", 931 "issue with the power supply itself, the power supply ", 932 "indicating this input fault should be called out. Add the ", 933 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 934 "CALLOUT_PRIORITY to something other than high." 935 ] 936 } 937 }, 938 939 { 940 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 941 "Subsystem": "power_supply", 942 "Severity": "unrecoverable_redundancy_loss", 943 "ActionFlags": ["service_action", "report", "call_home"], 944 "ComponentID": "0x2700", 945 946 "SRC": { 947 "Type": "11", 948 "ReasonCode": "0x15F1", 949 "Words6To9": {} 950 }, 951 952 "Documentation": { 953 "Description": "Power Supply power fault", 954 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 955 "Notes": [ 956 "The power supply reporting the fault should be called ", 957 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 958 "specific fault, STATUS_* details, and code level in the ", 959 "AdditionalData section." 960 ] 961 } 962 }, 963 964 { 965 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 966 "Subsystem": "power_supply", 967 "Severity": "unrecoverable", 968 "ActionFlags": ["service_action", "report", "call_home"], 969 "ComponentID": "0x2700", 970 971 "SRC": { 972 "Type": "11", 973 "ReasonCode": "0x15F2", 974 "Words6To9": {} 975 }, 976 977 "Documentation": { 978 "Description": "Power Supply non-power fault", 979 "Message": "A communication failure occurred talking to the power supply", 980 "Notes": [ 981 "Communication problems with the power supply could be ", 982 "the power supply, or any hardware between it and the ", 983 "BMC. Reporting the error should be passing in a call ", 984 "out using CALLOUT_DEVICE_PATH." 985 ] 986 } 987 }, 988 989 { 990 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 991 "Subsystem": "power_supply", 992 "Severity": "unrecoverable_redundancy_loss", 993 "ActionFlags": ["service_action", "report", "call_home"], 994 "ComponentID": "0x2700", 995 996 "SRC": { 997 "Type": "11", 998 "ReasonCode": "0x15F6", 999 "Words6To9": {} 1000 }, 1001 1002 "Callouts": [ 1003 { 1004 "CalloutList": [ 1005 { 1006 "Priority": "high", 1007 "SymbolicFRUTrusted": "pwrsply", 1008 "UseInventoryLocCode": true 1009 } 1010 ] 1011 } 1012 ], 1013 1014 "Documentation": { 1015 "Description": "Power Supply is missing", 1016 "Message": "A power supply that should be present is missing", 1017 "Notes": [ 1018 "The CalloutList should use the PWRSPLY symbolic FRU ", 1019 "with the trusted location code property. The ", 1020 "location code in this callout is obtained from ", 1021 "the passed in CALLOUT_INVENTORY_PATH value." 1022 ] 1023 } 1024 }, 1025 1026 { 1027 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 1028 "Subsystem": "power_supply", 1029 "Severity": "unrecoverable", 1030 "ActionFlags": ["service_action", "report", "call_home"], 1031 "ComponentID": "0x2700", 1032 1033 "SRC": { 1034 "Type": "11", 1035 "ReasonCode": "0x15F7", 1036 "Words6To9": {} 1037 }, 1038 1039 "Documentation": { 1040 "Description": "Power Supply configuration is not supported", 1041 "Message": "The power supply configuration is not supported", 1042 "Notes": [ 1043 "The combination of power supplies detected in the ", 1044 "system is not supported. This could be caused by ", 1045 "mismatched models, less than expected number of power ", 1046 "supplies, or other unsupported characteristics." 1047 ] 1048 } 1049 }, 1050 1051 { 1052 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.FanFault", 1053 "Subsystem": "power_supply", 1054 "Severity": "unrecoverable", 1055 "ActionFlags": ["service_action", "report", "call_home"], 1056 "ComponentID": "0x2700", 1057 1058 "SRC": { 1059 "Type": "11", 1060 "ReasonCode": "0x15FF", 1061 "Words6To9": {} 1062 }, 1063 1064 "Documentation": { 1065 "Description": "Power Supply fan fault", 1066 "Message": "A power supply indicated a fan fault has occurred", 1067 "Notes": [ 1068 "The power supply reporting the fault should be called ", 1069 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1070 "specific fault, STATUS_* details, and code level in the ", 1071 "AdditionalData section." 1072 ] 1073 } 1074 }, 1075 1076 { 1077 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 1078 "Subsystem": "power_supply", 1079 "Severity": "unrecoverable_redundancy_loss", 1080 "ActionFlags": ["service_action", "report", "call_home"], 1081 "ComponentID": "0x2700", 1082 1083 "SRC": { 1084 "Type": "11", 1085 "ReasonCode": "0x1B01", 1086 "Words6To9": {} 1087 }, 1088 1089 "Callouts": [ 1090 { 1091 "CalloutList": [ 1092 { "Priority": "high", "Procedure": "power_overcurrent" } 1093 ] 1094 } 1095 ], 1096 1097 "Documentation": { 1098 "Description": "Power Supply output over-current power fault", 1099 "Message": "A power supply has indicated an output over-current condition." 1100 } 1101 }, 1102 1103 { 1104 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1105 "Subsystem": "power", 1106 "ActionFlags": [ "report", "service_action" ], 1107 "Severity": "unrecoverable", 1108 "ComponentID": "0x2700", 1109 1110 "SRC": 1111 { 1112 "Type": "11", 1113 "ReasonCode": "0x00AC", 1114 "Words6To9": {}, 1115 "PowerFault": true 1116 }, 1117 1118 "Callouts": [ 1119 { 1120 "CalloutList": [ 1121 { "Priority": "high", "SymbolicFRU": "ac_module"} 1122 ] 1123 } 1124 ], 1125 1126 "Documentation": { 1127 "Description": "Input power was lost while the system was powered on.", 1128 "Message": "Input power was lost while the system was powered on.", 1129 "Notes": [ 1130 "Input power was lost while system powered on.", 1131 "The CalloutList should use the ACMODUL symbolic FRU." 1132 ] 1133 } 1134 }, 1135 1136 { 1137 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1138 "Subsystem": "power_supply", 1139 "Severity": "unrecoverable", 1140 "ActionFlags": ["service_action", "report", "call_home"], 1141 "ComponentID": "0x2700", 1142 1143 "SRC": { 1144 "Type": "11", 1145 "ReasonCode": "0x2500", 1146 "Words6To9": {}, 1147 "PowerFault": true 1148 }, 1149 1150 "Callouts": [ 1151 { 1152 "CalloutList": [ 1153 { "Priority": "high", "Procedure": "power_overcurrent" } 1154 ] 1155 } 1156 ], 1157 1158 "Documentation": { 1159 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1160 "Message": "Power supply PSKill_fault", 1161 "Notes": [ 1162 ] 1163 } 1164 }, 1165 1166 { 1167 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1168 "Subsystem": "power_sequencer", 1169 "ComponentID": "0x2700", 1170 1171 "SRC": { 1172 "Type": "11", 1173 "ReasonCode": "0x2600", 1174 "Words6To9": {} 1175 }, 1176 1177 "Callouts": [ 1178 { 1179 "CalloutList": [ 1180 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1181 ] 1182 } 1183 ], 1184 1185 "Documentation": { 1186 "Description": "A power off was issued because a power fault was detected", 1187 "Message": "A power off was issued because a power fault was detected", 1188 "Notes": [ 1189 ] 1190 } 1191 }, 1192 1193 { 1194 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1195 "Subsystem": "power_control_hw", 1196 "ComponentID": "0x2700", 1197 1198 "SRC": { 1199 "Type": "11", 1200 "ReasonCode": "0x2602", 1201 "Words6To9": {}, 1202 "PowerFault": true 1203 }, 1204 1205 "Callouts": [ 1206 { 1207 "System": "ibm,rainier", 1208 "CalloutList": [ 1209 { 1210 "Priority": "high", 1211 "LocCode": "P0-C5" 1212 }, 1213 { 1214 "Priority": "medium", 1215 "LocCode": "P0" 1216 } 1217 ] 1218 }, 1219 { 1220 "System": "ibm,everest", 1221 "CalloutList": [ 1222 { 1223 "Priority": "high", 1224 "LocCode": "P0-C59" 1225 }, 1226 { 1227 "Priority": "medium", 1228 "LocCode": "P0" 1229 } 1230 ] 1231 } 1232 ], 1233 1234 "Documentation": { 1235 "Description": "A power off was issued because a regulator for standby power faulted", 1236 "Message": "A power off was issued because a regulator for standby power faulted", 1237 "Notes": [ 1238 ] 1239 } 1240 }, 1241 1242 { 1243 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1244 "Subsystem": "power_sequencer", 1245 "ComponentID": "0x2700", 1246 1247 "SRC": { 1248 "Type": "11", 1249 "ReasonCode": "0x2610", 1250 "Words6To9": {} 1251 }, 1252 1253 "CalloutsUsingAD": { 1254 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1255 { 1256 "ADValue": "PCIE_SLOT0", "Callouts": [ 1257 { 1258 "CalloutList": [ 1259 { "Priority": "high", "LocCode": "P0-C0" }, 1260 { "Priority": "medium", "LocCode": "P0" } 1261 ] 1262 } 1263 ] 1264 }, 1265 { 1266 "ADValue": "PCIE_SLOT1", "Callouts": [ 1267 { 1268 "CalloutList": [ 1269 { "Priority": "high", "LocCode": "P0-C1" }, 1270 { "Priority": "medium", "LocCode": "P0" } 1271 ] 1272 } 1273 ] 1274 }, 1275 { 1276 "ADValue": "PCIE_SLOT2", "Callouts": [ 1277 { 1278 "CalloutList": [ 1279 { "Priority": "high", "LocCode": "P0-C2" }, 1280 { "Priority": "medium", "LocCode": "P0" } 1281 ] 1282 } 1283 ] 1284 }, 1285 { 1286 "ADValue": "PCIE_SLOT3", "Callouts": [ 1287 { 1288 "CalloutList": [ 1289 { "Priority": "high", "LocCode": "P0-C3" }, 1290 { "Priority": "medium", "LocCode": "P0" } 1291 ] 1292 } 1293 ] 1294 }, 1295 { 1296 "ADValue": "PCIE_SLOT4", "Callouts": [ 1297 { 1298 "CalloutList": [ 1299 { "Priority": "high", "LocCode": "P0-C4" }, 1300 { "Priority": "medium", "LocCode": "P0" } 1301 ] 1302 } 1303 ] 1304 }, 1305 { 1306 "ADValue": "PCIE_SLOT7", "Callouts": [ 1307 { 1308 "CalloutList": [ 1309 { "Priority": "high", "LocCode": "P0-C7" }, 1310 { "Priority": "medium", "LocCode": "P0" } 1311 ] 1312 } 1313 ] 1314 }, 1315 { 1316 "ADValue": "PCIE_SLOT8", "Callouts": [ 1317 { 1318 "CalloutList": [ 1319 { "Priority": "high", "LocCode": "P0-C8" }, 1320 { "Priority": "medium", "LocCode": "P0" } 1321 ] 1322 } 1323 ] 1324 }, 1325 { 1326 "ADValue": "PCIE_SLOT9", "Callouts": [ 1327 { 1328 "CalloutList": [ 1329 { "Priority": "high", "LocCode": "P0-C9" }, 1330 { "Priority": "medium", "LocCode": "P0" } 1331 ] 1332 } 1333 ] 1334 }, 1335 { 1336 "ADValue": "PCIE_SLOT10", "Callouts": [ 1337 { 1338 "CalloutList": [ 1339 { "Priority": "high", "LocCode": "P0-C10" }, 1340 { "Priority": "medium", "LocCode": "P0" } 1341 ] 1342 } 1343 ] 1344 }, 1345 { 1346 "ADValue": "PCIE_SLOT11", "Callouts": [ 1347 { 1348 "CalloutList": [ 1349 { "Priority": "high", "LocCode": "P0-C11" }, 1350 { "Priority": "medium", "LocCode": "P0" } 1351 ] 1352 } 1353 ] 1354 }, 1355 { 1356 "ADValue": "PGOOD_12A", "Callouts": [ 1357 { 1358 "CalloutList": [ 1359 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1360 ] 1361 } 1362 ] 1363 }, 1364 { 1365 "ADValue": "PGOOD_12B", "Callouts": [ 1366 { 1367 "CalloutList": [ 1368 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1369 ] 1370 } 1371 ] 1372 }, 1373 { 1374 "ADValue": "PGOOD_12C", "Callouts": [ 1375 { 1376 "CalloutList": [ 1377 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1378 ] 1379 } 1380 ] 1381 }, 1382 { 1383 "ADValue": "PGOOD_12D", "Callouts": [ 1384 { 1385 "CalloutList": [ 1386 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1387 ] 1388 } 1389 ] 1390 }, 1391 { 1392 "ADValue": "PGOOD_12L", "Callouts": [ 1393 { 1394 "CalloutList": [ 1395 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1396 ] 1397 } 1398 ] 1399 }, 1400 { 1401 "ADValue": "PGOOD_12M", "Callouts": [ 1402 { 1403 "CalloutList": [ 1404 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1405 ] 1406 } 1407 ] 1408 }, 1409 { 1410 "ADValue": "PGOOD_12N", "Callouts": [ 1411 { 1412 "CalloutList": [ 1413 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1414 ] 1415 } 1416 ] 1417 }, 1418 { 1419 "ADValue": "PGOOD_12P", "Callouts": [ 1420 { 1421 "CalloutList": [ 1422 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1423 ] 1424 } 1425 ] 1426 }, 1427 { 1428 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1429 { 1430 "CalloutList": [ 1431 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1432 ] 1433 } 1434 ] 1435 }, 1436 { 1437 "ADValue": "PGOOD_12Q", "Callouts": [ 1438 { 1439 "CalloutList": [ 1440 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1441 ] 1442 } 1443 ] 1444 }, 1445 { 1446 "ADValue": "PGOOD_12R", "Callouts": [ 1447 { 1448 "CalloutList": [ 1449 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1450 ] 1451 } 1452 ] 1453 }, 1454 { 1455 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1456 { 1457 "CalloutList": [ 1458 { "Priority": "high", "LocCode": "P0-C14" }, 1459 { "Priority": "medium", "LocCode": "P0-C15" }, 1460 { "Priority": "low", "LocCode": "P0" } 1461 ] 1462 } 1463 ] 1464 }, 1465 { 1466 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1467 { 1468 "CalloutList": [ 1469 { "Priority": "high", "LocCode": "P0-C23" }, 1470 { "Priority": "medium", "LocCode": "P0-C24" }, 1471 { "Priority": "low", "LocCode": "P0" } 1472 ] 1473 } 1474 ] 1475 }, 1476 { 1477 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1478 { 1479 "CalloutList": [ 1480 { "Priority": "high", "LocCode": "P0-C14" }, 1481 { "Priority": "medium", "LocCode": "P0-C15" }, 1482 { "Priority": "low", "LocCode": "P0" } 1483 ] 1484 } 1485 ] 1486 }, 1487 { 1488 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1489 { 1490 "CalloutList": [ 1491 { "Priority": "high", "LocCode": "P0-C23" }, 1492 { "Priority": "medium", "LocCode": "P0-C24" }, 1493 { "Priority": "low", "LocCode": "P0" } 1494 ] 1495 } 1496 ] 1497 }, 1498 { 1499 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1500 { 1501 "CalloutList": [ 1502 { "Priority": "high", "LocCode": "P0-C14" }, 1503 { "Priority": "medium", "LocCode": "P0-C15" }, 1504 { "Priority": "low", "LocCode": "P0" } 1505 ] 1506 } 1507 ] 1508 }, 1509 { 1510 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1511 { 1512 "CalloutList": [ 1513 { "Priority": "high", "LocCode": "P0-C23" }, 1514 { "Priority": "medium", "LocCode": "P0-C24" }, 1515 { "Priority": "low", "LocCode": "P0" } 1516 ] 1517 } 1518 ] 1519 }, 1520 { 1521 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1522 { 1523 "CalloutList": [ 1524 { "Priority": "high", "LocCode": "P0-C14" }, 1525 { "Priority": "medium", "LocCode": "P0-C15" }, 1526 { "Priority": "low", "LocCode": "P0" } 1527 ] 1528 } 1529 ] 1530 }, 1531 { 1532 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1533 { 1534 "CalloutList": [ 1535 { "Priority": "high", "LocCode": "P0-C23" }, 1536 { "Priority": "medium", "LocCode": "P0-C24" }, 1537 { "Priority": "low", "LocCode": "P0" } 1538 ] 1539 } 1540 ] 1541 } 1542 ] 1543 }, 1544 1545 "Documentation": { 1546 "Description": "The power sequencer chip detected a PGOOD fault", 1547 "Message": "The power sequencer chip detected a PGOOD fault", 1548 "Notes": [ 1549 ] 1550 } 1551 }, 1552 1553 { 1554 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 1555 "Subsystem": "power_sequencer", 1556 "ComponentID": "0x2700", 1557 1558 "SRC": { 1559 "Type": "11", 1560 "ReasonCode": "0x2620", 1561 "Words6To9": {} 1562 }, 1563 1564 "CalloutsUsingAD": { 1565 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 1566 { 1567 "ADValue": "12.0V", "Callouts": [ 1568 { 1569 "CalloutList": [ 1570 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1571 ] 1572 } 1573 ] 1574 }, 1575 { 1576 "ADValue": "5.0V_USB", "Callouts": [ 1577 { 1578 "CalloutList": [ 1579 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1580 { "Priority": "medium", "LocCode": "P0" } 1581 ] 1582 } 1583 ] 1584 }, 1585 { 1586 "ADValue": "5.0V_DASD", "Callouts": [ 1587 { 1588 "CalloutList": [ 1589 { "Priority": "medium", "LocCode": "P1" }, 1590 { "Priority": "medium", "LocCode": "P2" }, 1591 { "Priority": "medium", "LocCode": "P3" }, 1592 { "Priority": "low", "LocCode": "P0" } 1593 ] 1594 } 1595 ] 1596 }, 1597 { 1598 "ADValue": "3.3VA", "Callouts": [ 1599 { 1600 "CalloutList": [ 1601 { "Priority": "high", "LocCode": "P0" } 1602 ] 1603 } 1604 ] 1605 }, 1606 { 1607 "ADValue": "3.3VB", "Callouts": [ 1608 { 1609 "CalloutList": [ 1610 { "Priority": "high", "LocCode": "P0" } 1611 ] 1612 } 1613 ] 1614 }, 1615 { 1616 "ADValue": "1.5V", "Callouts": [ 1617 { 1618 "CalloutList": [ 1619 { "Priority": "high", "LocCode": "P0" } 1620 ] 1621 } 1622 ] 1623 }, 1624 { 1625 "ADValue": "1.1V", "Callouts": [ 1626 { 1627 "CalloutList": [ 1628 { "Priority": "high", "LocCode": "P0" } 1629 ] 1630 } 1631 ] 1632 }, 1633 { 1634 "ADValue": "VDDA_DCM0", "Callouts": [ 1635 { 1636 "CalloutList": [ 1637 { "Priority": "high", "LocCode": "P0-C14" }, 1638 { "Priority": "medium", "LocCode": "P0-C15" }, 1639 { "Priority": "low", "LocCode": "P0" } 1640 ] 1641 } 1642 ] 1643 }, 1644 { 1645 "ADValue": "VDDB_DCM0", "Callouts": [ 1646 { 1647 "CalloutList": [ 1648 { "Priority": "high", "LocCode": "P0-C14" }, 1649 { "Priority": "medium", "LocCode": "P0-C15" }, 1650 { "Priority": "low", "LocCode": "P0" } 1651 ] 1652 } 1653 ] 1654 }, 1655 { 1656 "ADValue": "VDDA_DCM1", "Callouts": [ 1657 { 1658 "CalloutList": [ 1659 { "Priority": "high", "LocCode": "P0-C23" }, 1660 { "Priority": "medium", "LocCode": "P0-C24" }, 1661 { "Priority": "low", "LocCode": "P0" } 1662 ] 1663 } 1664 ] 1665 }, 1666 { 1667 "ADValue": "VDDB_DCM1", "Callouts": [ 1668 { 1669 "CalloutList": [ 1670 { "Priority": "high", "LocCode": "P0-C23" }, 1671 { "Priority": "medium", "LocCode": "P0-C24" }, 1672 { "Priority": "low", "LocCode": "P0" } 1673 ] 1674 } 1675 ] 1676 }, 1677 { 1678 "ADValue": "12.0VCS", "Callouts": [ 1679 { 1680 "CalloutList": [ 1681 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1682 ] 1683 } 1684 ] 1685 }, 1686 { 1687 "ADValue": "3.3VCS", "Callouts": [ 1688 { 1689 "CalloutList": [ 1690 { "Priority": "high", "LocCode": "P0" } 1691 ] 1692 } 1693 ] 1694 }, 1695 { 1696 "ADValue": "1.1V_Current", "Callouts": [ 1697 { 1698 "CalloutList": [ 1699 { "Priority": "high", "LocCode": "P0" } 1700 ] 1701 } 1702 ] 1703 }, 1704 { 1705 "ADValue": "5.0V_USB_Current", "Callouts": [ 1706 { 1707 "CalloutList": [ 1708 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1709 { "Priority": "medium", "LocCode": "P0" } 1710 ] 1711 } 1712 ] 1713 }, 1714 { 1715 "ADValue": "5.0V_DASD_Current", "Callouts": [ 1716 { 1717 "CalloutList": [ 1718 { "Priority": "medium", "LocCode": "P1" }, 1719 { "Priority": "medium", "LocCode": "P2" }, 1720 { "Priority": "medium", "LocCode": "P3" }, 1721 { "Priority": "low", "LocCode": "P0" } 1722 ] 1723 } 1724 ] 1725 }, 1726 { 1727 "ADValue": "12.0VN", "Callouts": [ 1728 { 1729 "CalloutList": [ 1730 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1731 ] 1732 } 1733 ] 1734 }, 1735 { 1736 "ADValue": "12.0VP", "Callouts": [ 1737 { 1738 "CalloutList": [ 1739 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1740 ] 1741 } 1742 ] 1743 }, 1744 { 1745 "ADValue": "12.0VQ", "Callouts": [ 1746 { 1747 "CalloutList": [ 1748 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1749 ] 1750 } 1751 ] 1752 }, 1753 { 1754 "ADValue": "12.0VR", "Callouts": [ 1755 { 1756 "CalloutList": [ 1757 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1758 ] 1759 } 1760 ] 1761 }, 1762 { 1763 "ADValue": "ThermalDiode1", "Callouts": [ 1764 { 1765 "CalloutList": [ 1766 { "Priority": "high", "LocCode": "P0" } 1767 ] 1768 } 1769 ] 1770 }, 1771 { 1772 "ADValue": "ThermalDiode2", "Callouts": [ 1773 { 1774 "CalloutList": [ 1775 { "Priority": "high", "LocCode": "P0" } 1776 ] 1777 } 1778 ] 1779 }, 1780 { 1781 "ADValue": "ThermalDiode3", "Callouts": [ 1782 { 1783 "CalloutList": [ 1784 { "Priority": "high", "LocCode": "P0" } 1785 ] 1786 } 1787 ] 1788 }, 1789 { 1790 "ADValue": "ThermalDiode4", "Callouts": [ 1791 { 1792 "CalloutList": [ 1793 { "Priority": "high", "LocCode": "P0" } 1794 ] 1795 } 1796 ] 1797 } 1798 ] 1799 }, 1800 1801 "Documentation": { 1802 "Description": "The power sequencer chip detected a voltage fault", 1803 "Message": "The power sequencer chip detected a voltage fault", 1804 "Notes": [ 1805 ] 1806 } 1807 }, 1808 1809 { 1810 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 1811 "Subsystem": "power", 1812 "Severity": "predictive_redundancy_loss", 1813 "ComponentID": "0x2700", 1814 1815 "SRC": { 1816 "Type": "11", 1817 "ReasonCode": "0x2700", 1818 "Words6To9": {} 1819 }, 1820 1821 "Documentation": { 1822 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1823 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1824 "Notes": [ 1825 "CALLOUT_INVENTORY_PATH should be specified in the ", 1826 "AdditionalData property of the event log so that ", 1827 "the device is called out but not the communication path." 1828 ] 1829 } 1830 }, 1831 1832 { 1833 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 1834 "Subsystem": "power", 1835 "Severity": "non_error", 1836 "MfgSeverity": "predictive_redundancy_loss", 1837 "ActionFlags": ["report"], 1838 "MfgActionFlags": ["service_action", "report", "call_home"], 1839 "ComponentID": "0x2700", 1840 1841 "SRC": { 1842 "Type": "11", 1843 "ReasonCode": "0x2701", 1844 "Words6To9": {} 1845 }, 1846 1847 "Documentation": { 1848 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1849 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1850 "Notes": [ 1851 "CALLOUT_INVENTORY_PATH should be specified in the ", 1852 "AdditionalData property of the event log so that ", 1853 "the device is called out but not the communication path." 1854 ] 1855 } 1856 }, 1857 1858 { 1859 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 1860 "Subsystem": "power", 1861 "ComponentID": "0x2700", 1862 1863 "SRC": { 1864 "Type": "11", 1865 "ReasonCode": "0x2900", 1866 "Words6To9": {} 1867 }, 1868 1869 "Documentation": { 1870 "Description": "A write verification error occurred on a device", 1871 "Message": "A write verification error occurred on a device", 1872 "Notes": [ 1873 "This error occurs when a device register is written, ", 1874 "read back, and the two values do not match. This is ", 1875 "also called a read-back error. The device should be ", 1876 "identified using the CALLOUT_DEVICE_PATH or ", 1877 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 1878 "AdditionalData property of the event log. This will ", 1879 "cause the device and the hardware in the communication ", 1880 "path to be called out." 1881 ] 1882 } 1883 }, 1884 1885 { 1886 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 1887 "Subsystem": "power", 1888 "ComponentID": "0x2700", 1889 1890 "SRC": { 1891 "Type": "11", 1892 "ReasonCode": "0xA013", 1893 "Words6To9": {} 1894 }, 1895 1896 "Callouts": [ 1897 { 1898 "CalloutList": [ 1899 { "Priority": "high", "Procedure": "bmc_code" } 1900 ] 1901 } 1902 ], 1903 1904 "Documentation": { 1905 "Description": "A regulators configuration file error occurred", 1906 "Message": "A regulators configuration file error occurred", 1907 "Notes": [ 1908 "The regulators configuration file could not be found, ", 1909 "could not be read, or had invalid contents." 1910 ] 1911 } 1912 }, 1913 1914 { 1915 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 1916 "Subsystem": "power", 1917 "Severity": "critical_system_term", 1918 "ComponentID": "0x2700", 1919 1920 "SRC": { 1921 "Type": "11", 1922 "ReasonCode": "0xA014", 1923 "Words6To9": {}, 1924 "PowerFault": true 1925 }, 1926 1927 "Callouts": [ 1928 { 1929 "CalloutList": [ 1930 { "Priority": "high", "Procedure": "bmc_code" } 1931 ] 1932 } 1933 ], 1934 1935 "Documentation": { 1936 "Description": "A critical regulators configuration file error occurred", 1937 "Message": "A critical regulators configuration file error occurred", 1938 "Notes": [ 1939 "The regulators configuration file could not be found, ", 1940 "could not be read, or had invalid contents. As a result ", 1941 "voltage regulators could not be configured, and the ", 1942 "chassis could not be powered on." 1943 ] 1944 } 1945 }, 1946 1947 { 1948 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 1949 "Subsystem": "power_sequencer", 1950 "ComponentID": "0x2700", 1951 1952 "SRC": { 1953 "Type": "11", 1954 "ReasonCode": "0xD000", 1955 "Words6To9": {} 1956 }, 1957 1958 "Callouts": [ 1959 { 1960 "CalloutList": [ 1961 { "Priority": "high", "LocCode": "P0" } 1962 ] 1963 } 1964 ], 1965 1966 "Documentation": { 1967 "Description": "The power sequencer chip detected a fault", 1968 "Message": "The power sequencer chip detected a fault", 1969 "Notes": [ 1970 ] 1971 } 1972 }, 1973 1974 { 1975 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 1976 "Subsystem": "power_sequencer", 1977 "ComponentID": "0x2700", 1978 "Severity": "critical", 1979 1980 "SRC": { 1981 "Type": "11", 1982 "ReasonCode": "0xD002", 1983 "Words6To9": {} 1984 }, 1985 1986 "Callouts": [ 1987 { 1988 "CalloutList": [ 1989 { "Priority": "high", "LocCode": "P0" } 1990 ] 1991 } 1992 ], 1993 1994 "Documentation": { 1995 "Description": "System power failed to turn on within timeout period", 1996 "Message": "System power failed to turn on within timeout period", 1997 "Notes": [ 1998 ] 1999 } 2000 }, 2001 2002 { 2003 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 2004 "Subsystem": "power_sequencer", 2005 "ComponentID": "0x2700", 2006 "Severity": "critical", 2007 2008 "SRC": { 2009 "Type": "11", 2010 "ReasonCode": "0xD008", 2011 "Words6To9": {} 2012 }, 2013 2014 "Callouts": [ 2015 { 2016 "CalloutList": [ 2017 { "Priority": "high", "LocCode": "P0" } 2018 ] 2019 } 2020 ], 2021 2022 "Documentation": { 2023 "Description": "System power failed to turn off within timeout period", 2024 "Message": "System power failed to turn off within timeout period", 2025 "Notes": [ 2026 ] 2027 } 2028 }, 2029 2030 { 2031 "Name": "xyz.openbmc_project.Power.Error.Internal", 2032 "Subsystem": "power", 2033 "ComponentID": "0x2700", 2034 2035 "SRC": { 2036 "Type": "11", 2037 "ReasonCode": "0xE000", 2038 "Words6To9": {} 2039 }, 2040 2041 "Callouts": [ 2042 { 2043 "CalloutList": [ 2044 { "Priority": "high", "Procedure": "bmc_code" } 2045 ] 2046 } 2047 ], 2048 2049 "Documentation": { 2050 "Description": "An internal firmware error occurred", 2051 "Message": "An internal firmware error occurred", 2052 "Notes": [ 2053 "The error details must be provided in the AdditionalData ", 2054 "property of the event log." 2055 ] 2056 } 2057 }, 2058 2059 { 2060 "Name": "xyz.openbmc_project.Power.Error.I2C", 2061 "Subsystem": "cec_i2c", 2062 "ComponentID": "0x2700", 2063 2064 "SRC": { 2065 "Type": "11", 2066 "ReasonCode": "0xE100", 2067 "Words6To9": {} 2068 }, 2069 2070 "Documentation": { 2071 "Description": "An I2C error occurred communicating with a device", 2072 "Message": "An I2C error occurred communicating with a device", 2073 "Notes": [ 2074 "The device should be identified using the ", 2075 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 2076 "keywords in the AdditionalData property of the event ", 2077 "log. This will cause the device and the hardware in the ", 2078 "communication path to be called out." 2079 ] 2080 } 2081 }, 2082 2083 { 2084 "Name": "xyz.openbmc_project.Power.Error.PMBus", 2085 "Subsystem": "power", 2086 "ComponentID": "0x2700", 2087 2088 "SRC": { 2089 "Type": "11", 2090 "ReasonCode": "0xE200", 2091 "Words6To9": {} 2092 }, 2093 2094 "Documentation": { 2095 "Description": "A PMBus error occurred on a device", 2096 "Message": "A PMBus error occurred on a device", 2097 "Notes": [ 2098 "This error occurs when the I2C communication was ", 2099 "successful, but the PMBus value read is invalid or ", 2100 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 2101 "in the AdditionalData property of the event log so that ", 2102 "the device is called out but not the communication path." 2103 ] 2104 } 2105 }, 2106 2107 { 2108 "Name": "xyz.openbmc_project.Power.Error.DBus", 2109 "Subsystem": "power", 2110 "ComponentID": "0x2700", 2111 2112 "SRC": { 2113 "Type": "11", 2114 "ReasonCode": "0xE300", 2115 "Words6To9": {} 2116 }, 2117 2118 "Callouts": [ 2119 { 2120 "CalloutList": [ 2121 { "Priority": "high", "Procedure": "bmc_code" } 2122 ] 2123 } 2124 ], 2125 2126 "Documentation": { 2127 "Description": "A firmware inter-process communication (D-Bus) error occurred", 2128 "Message": "A firmware inter-process communication (D-Bus) error occurred" 2129 } 2130 }, 2131 2132 { 2133 "Name": "xyz.openbmc_project.Fan.Error.Fault", 2134 "Subsystem": "power_fans", 2135 "ComponentID": "0x2800", 2136 2137 "SRC": { 2138 "Type": "11", 2139 "ReasonCode": "0x76F0", 2140 "Words6To9": {} 2141 }, 2142 2143 "Documentation": { 2144 "Description": "Fan rotor fault", 2145 "Message": "Fan rotor fault", 2146 "Notes": [ 2147 "This error occurs when a fan rotor has been faulted for a ", 2148 "certain amount of time. The callout is the fan which is ", 2149 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 2150 "passed in during creation and will be either informational ", 2151 "or unrecoverable. The action flags use the defaults and ", 2152 "vary based on the severity." 2153 ] 2154 } 2155 }, 2156 2157 { 2158 "Name": "xyz.openbmc_project.Fan.Error.Missing", 2159 "Subsystem": "power_fans", 2160 "ComponentID": "0x2800", 2161 "Severity": "unrecoverable_redundancy_loss", 2162 "ActionFlags": ["service_action", "report", "call_home"], 2163 2164 "SRC": { 2165 "Type": "11", 2166 "ReasonCode": "0x76F1", 2167 "Words6To9": {} 2168 }, 2169 2170 "Callouts": [ 2171 { 2172 "System": "ibm,rainier", 2173 "CalloutList": [ 2174 { 2175 "Priority": "high", 2176 "SymbolicFRUTrusted": "air_mover", 2177 "UseInventoryLocCode": true 2178 }, 2179 { 2180 "Priority": "low", 2181 "LocCode": "P0" 2182 } 2183 ] 2184 }, 2185 { 2186 "System": "ibm,everest", 2187 "CalloutList": [ 2188 { 2189 "Priority": "high", 2190 "SymbolicFRUTrusted": "air_mover", 2191 "UseInventoryLocCode": true 2192 }, 2193 { 2194 "Priority": "low", 2195 "LocCode": "P1" 2196 } 2197 ] 2198 } 2199 ], 2200 2201 "Documentation": { 2202 "Description": "A fan is missing", 2203 "Message": "A fan is missing", 2204 "Notes": [ 2205 "This error occurs when a fan has been missing for a ", 2206 "certain amount of time. The first callout is the ", 2207 "symbolic FRU AIR_MOVR that has the trusted fan location ", 2208 "code, which it gets using the passed in ", 2209 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 2210 "where the controller and GPIO expander are." 2211 ] 2212 } 2213 }, 2214 2215 { 2216 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 2217 "ComponentID": "0x2800", 2218 "Subsystem": "power_fans", 2219 "Severity": "non_error", 2220 "ActionFlags": ["report"], 2221 "MfgSeverity": "predictive", 2222 "MfgActionFlags": ["service_action", "report"], 2223 2224 "SRC": { 2225 "Type": "11", 2226 "ReasonCode": "0x76F2", 2227 "Words6To9": {} 2228 }, 2229 2230 "Callouts": [ 2231 { 2232 "System": "ibm,rainier", 2233 "CalloutList": [ 2234 {"Priority": "medium", "LocCode": "P0"} 2235 ] 2236 }, 2237 { 2238 "System": "ibm,everest", 2239 "CalloutList": [ 2240 {"Priority": "medium", "LocCode": "P1"} 2241 ] 2242 } 2243 ], 2244 2245 "Documentation": { 2246 "Description": "Presence detect methods for the same fan disagree", 2247 "Message": "Presence detect methods for the same fan disagree", 2248 "Notes": [ 2249 "This error occurs when there is more than one way to detect", 2250 "fan presence, and they don't all agree. For example, the", 2251 "GPIO says a fan isn't present, but the tach readings are", 2252 "nonzero. This is informational, unless in manufacturing.", 2253 "The fan FRU is passed in as a high priority callout.", 2254 "The FRU the GPIO source is on is called out medium." 2255 ] 2256 } 2257 }, 2258 2259 { 2260 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 2261 "ComponentID": "0x2800", 2262 "Subsystem": "power_fans", 2263 "Severity": "critical_system_term", 2264 "ActionFlags": ["service_action", "report", "call_home"], 2265 2266 "SRC": { 2267 "Type": "11", 2268 "ReasonCode": "0x76F3", 2269 "Words6To9": {}, 2270 "PowerFault": true 2271 }, 2272 2273 "Callouts": [ 2274 { 2275 "System": "ibm,rainier", 2276 "CalloutList": [ 2277 {"Priority": "high", "LocCode": "P0-C5"}, 2278 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 2279 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 2280 {"Priority": "low", "LocCode": "P0"} 2281 ] 2282 }, 2283 { 2284 "System": "ibm,everest", 2285 "CalloutList": [ 2286 {"Priority": "high", "LocCode": "P0-C0"}, 2287 {"Priority": "medium", "LocCode": "P1"}, 2288 {"Priority": "low", "LocCode": "P0"} 2289 ] 2290 } 2291 ], 2292 2293 "Documentation": { 2294 "Description": "The fan controller device is offline", 2295 "Message": "The fan controller is offline. The system must be powered off.", 2296 "Notes": [ 2297 "The device that controls the fans is offline so the fan", 2298 "targets and speeds are unknown. The system will be shut", 2299 "down to preserve thermal safety. There may be an I2C", 2300 "or power problem with the device." 2301 ] 2302 } 2303 }, 2304 2305 { 2306 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 2307 "Subsystem": "power_fans", 2308 "ComponentID": "0x2800", 2309 "Severity": "unrecoverable_redundancy_loss", 2310 "ActionFlags": ["service_action", "report", "call_home"], 2311 2312 "SRC": { 2313 "Type": "11", 2314 "ReasonCode": "0x76F4", 2315 "Words6To9": {} 2316 }, 2317 2318 "Callouts": [ 2319 { 2320 "System" : "ibm,rainier", 2321 "CalloutList": [ 2322 {"Priority": "high", "LocCode": "P0-C5"}, 2323 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 2324 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 2325 {"Priority": "low", "LocCode": "P0"} 2326 ] 2327 }, 2328 { 2329 "System" : "ibm,everest", 2330 "CalloutList": [ 2331 {"Priority": "high", "LocCode": "P0-C0"}, 2332 {"Priority": "medium", "LocCode": "P1"}, 2333 {"Priority": "low", "LocCode": "P0"} 2334 ] 2335 } 2336 ], 2337 2338 "Documentation": { 2339 "Description": "Fan GPIO sensors not present", 2340 "Message": "Fan GPIO sensors not present", 2341 "Notes": [ 2342 "The device that reports fan presence is not functioning." 2343 ] 2344 } 2345 }, 2346 2347 { 2348 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 2349 "Subsystem": "power", 2350 "ComponentID": "0x2800", 2351 "Severity": "predictive", 2352 "ActionFlags": ["service_action", "report"], 2353 2354 "SRC": { 2355 "ReasonCode": "0x2801", 2356 "Words6To9": {} 2357 }, 2358 2359 "CalloutsUsingAD": { 2360 "ADName": "SENSOR_NAME", 2361 "CalloutsWithTheirADValues": [ 2362 { 2363 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2364 "Callouts": [ 2365 { 2366 "CalloutList": [ 2367 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2368 ] 2369 } 2370 ] 2371 } 2372 ] 2373 }, 2374 2375 "Documentation": { 2376 "Description": "A temperature sensor exceeded its performance loss threshold.", 2377 "Message": "A temperature sensor exceeded its performance loss threshold.", 2378 "Notes": [ 2379 "A temperature sensor crossed its performance loss threshold value", 2380 "If it is the ambient sensor, then a symbolic FRU will be added.", 2381 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2382 "a FRU callout." 2383 ] 2384 } 2385 }, 2386 2387 { 2388 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 2389 "Subsystem": "power", 2390 "ComponentID": "0x2800", 2391 "Severity": "non_error", 2392 "ActionFlags": ["report"], 2393 "EventType": "env_normal", 2394 2395 "SRC": { 2396 "ReasonCode": "0x2802", 2397 "Words6To9": {} 2398 }, 2399 2400 "CalloutsUsingAD": { 2401 "ADName": "SENSOR_NAME", 2402 "CalloutsWithTheirADValues": [ 2403 { 2404 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2405 "Callouts": [ 2406 { 2407 "CalloutList": [ 2408 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2409 ] 2410 } 2411 ] 2412 } 2413 ] 2414 }, 2415 2416 "Documentation": { 2417 "Description": "A temperature sensor is under its performance loss threshold.", 2418 "Message": "A temperature sensor is under its performance loss threshold.", 2419 "Notes": [ 2420 "A temperature sensor crossed under its performance loss threshold value", 2421 "If it is the ambient sensor, then a symbolic FRU will be added." 2422 ] 2423 } 2424 }, 2425 2426 { 2427 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 2428 "Subsystem": "power", 2429 "ComponentID": "0x2800", 2430 "Severity": "predictive", 2431 "ActionFlags": ["service_action", "report"], 2432 2433 "SRC": { 2434 "ReasonCode": "0x2803", 2435 "Words6To9": {} 2436 }, 2437 2438 "CalloutsUsingAD": { 2439 "ADName": "SENSOR_NAME", 2440 "CalloutsWithTheirADValues": [ 2441 { 2442 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2443 "Callouts": [ 2444 { 2445 "CalloutList": [ 2446 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2447 ] 2448 } 2449 ] 2450 } 2451 ] 2452 }, 2453 2454 "Documentation": { 2455 "Description": "A temperature sensor exceeded its warning threshold.", 2456 "Message": "A temperature sensor exceeded its warning threshold.", 2457 "Notes": [ 2458 "A temperature sensor crossed its warning threshold value", 2459 "If it is the ambient sensor, then a symbolic FRU will be added.", 2460 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2461 "a FRU callout." 2462 ] 2463 } 2464 }, 2465 2466 { 2467 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 2468 "Subsystem": "power", 2469 "ComponentID": "0x2800", 2470 "Severity": "non_error", 2471 "ActionFlags": ["report"], 2472 "EventType": "env_normal", 2473 2474 "SRC": { 2475 "ReasonCode": "0x2804", 2476 "Words6To9": {} 2477 }, 2478 2479 "CalloutsUsingAD": { 2480 "ADName": "SENSOR_NAME", 2481 "CalloutsWithTheirADValues": [ 2482 { 2483 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2484 "Callouts": [ 2485 { 2486 "CalloutList": [ 2487 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2488 ] 2489 } 2490 ] 2491 } 2492 ] 2493 }, 2494 2495 "Documentation": { 2496 "Description": "A temperature sensor is under its warning threshold.", 2497 "Message": "A temperature sensor is under its warning threshold.", 2498 "Notes": [ 2499 "A temperature sensor crossed under its warning threshold value", 2500 "If it is the ambient sensor, then a symbolic FRU will be added." 2501 ] 2502 } 2503 }, 2504 2505 { 2506 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 2507 "Subsystem": "power", 2508 "ComponentID": "0x2800", 2509 "Severity": "predictive", 2510 "ActionFlags": ["service_action", "report"], 2511 2512 "SRC": { 2513 "ReasonCode": "0x2805", 2514 "Words6To9": {} 2515 }, 2516 2517 "CalloutsUsingAD": { 2518 "ADName": "SENSOR_NAME", 2519 "CalloutsWithTheirADValues": [ 2520 { 2521 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2522 "Callouts": [ 2523 { 2524 "CalloutList": [ 2525 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2526 ] 2527 } 2528 ] 2529 } 2530 ] 2531 }, 2532 2533 "Documentation": { 2534 "Description": "A temperature sensor exceeded its critical threshold.", 2535 "Message": "A temperature sensor exceeded its critical threshold.", 2536 "Notes": [ 2537 "A temperature sensor crossed its critical threshold value", 2538 "If it is the ambient sensor, then a symbolic FRU will be added.", 2539 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2540 "a FRU callout." 2541 ] 2542 } 2543 }, 2544 2545 { 2546 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 2547 "Subsystem": "power", 2548 "ComponentID": "0x2800", 2549 "Severity": "non_error", 2550 "ActionFlags": ["report"], 2551 "EventType": "env_normal", 2552 2553 "SRC": { 2554 "ReasonCode": "0x2806", 2555 "Words6To9": {} 2556 }, 2557 2558 "CalloutsUsingAD": { 2559 "ADName": "SENSOR_NAME", 2560 "CalloutsWithTheirADValues": [ 2561 { 2562 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2563 "Callouts": [ 2564 { 2565 "CalloutList": [ 2566 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2567 ] 2568 } 2569 ] 2570 } 2571 ] 2572 }, 2573 2574 "Documentation": { 2575 "Description": "A temperature sensor is under its critical threshold.", 2576 "Message": "A temperature sensor is under its critical threshold.", 2577 "Notes": [ 2578 "A temperature sensor crossed under its critical threshold value", 2579 "If it is the ambient sensor, then a symbolic FRU will be added." 2580 ] 2581 } 2582 }, 2583 2584 { 2585 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 2586 "Subsystem": "power", 2587 "ComponentID": "0x2800", 2588 "Severity": "predictive", 2589 "ActionFlags": ["service_action", "report"], 2590 2591 "SRC": { 2592 "ReasonCode": "0x2807", 2593 "Words6To9": {} 2594 }, 2595 2596 "Callouts": [ 2597 { 2598 "CalloutList": [ 2599 { 2600 "Priority": "high", 2601 "SymbolicFRU": "ambient_temp" 2602 } 2603 ] 2604 } 2605 ], 2606 2607 "Documentation": { 2608 "Description": "The ambient temperature passed the EPOW3 limit.", 2609 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 2610 "Notes": [ 2611 "This error occurs when the ambient temperature surpassed", 2612 "the EPOW3 shutdown limit." 2613 ] 2614 } 2615 }, 2616 2617 { 2618 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 2619 "Subsystem": "power", 2620 "ComponentID": "0x2800", 2621 "Severity": "non_error", 2622 "ActionFlags": ["report"], 2623 "EventType": "env_normal", 2624 2625 "SRC": { 2626 "ReasonCode": "0x2808", 2627 "Words6To9": {} 2628 }, 2629 2630 "Callouts": [ 2631 { 2632 "CalloutList": [ 2633 { 2634 "Priority": "high", 2635 "SymbolicFRU": "ambient_temp_back" 2636 } 2637 ] 2638 } 2639 ], 2640 2641 "Documentation": { 2642 "Description": "The ambient temperature is back under the EPOW3 limit.", 2643 "Message": "The ambient temperature is back under the EPOW3 limit." 2644 } 2645 }, 2646 2647 { 2648 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 2649 "Subsystem": "power", 2650 "ComponentID": "0x2800", 2651 "ActionFlags": ["service_action", "report"], 2652 2653 "SRC": { 2654 "ReasonCode": "0x2809", 2655 "Words6To9": {} 2656 }, 2657 2658 "Callouts": [ 2659 { 2660 "CalloutList": [ 2661 { 2662 "Priority": "high", 2663 "SymbolicFRU": "ambient_temp" 2664 } 2665 ] 2666 } 2667 ], 2668 2669 "Documentation": { 2670 "Description": "The ambient temperature passed the EPOW4 limit.", 2671 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 2672 "Notes": [ 2673 "This error occurs when the ambient temperature surpassed", 2674 "the EPOW4 shutdown limit." 2675 ] 2676 } 2677 }, 2678 2679 { 2680 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 2681 "Subsystem": "ext_env", 2682 "ComponentID": "0x2800", 2683 "Severity": "predictive", 2684 "ActionFlags": ["service_action", "report"], 2685 2686 "SRC": { 2687 "ReasonCode": "0x280A", 2688 "Words6To9": {} 2689 }, 2690 2691 "CalloutsUsingAD": { 2692 "ADName": "SENSOR_NAME", 2693 "CalloutsWithTheirADValues": [ 2694 { 2695 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 2696 "Callouts": [ 2697 { 2698 "CalloutList": [ 2699 { "Priority": "high", "SymbolicFRU": "altitude" } 2700 ] 2701 } 2702 ] 2703 } 2704 ] 2705 }, 2706 2707 "Documentation": { 2708 "Description": "An altitude sensor exceeded its warning threshold.", 2709 "Message": "An altitude sensor exceeded its warning threshold.", 2710 "Notes": [ 2711 "The virtual altitude sensor crossed its warning threshold value", 2712 " and a symbolic FRU will be added." 2713 ] 2714 } 2715 }, 2716 2717 { 2718 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 2719 "Subsystem": "ext_env", 2720 "ComponentID": "0x2800", 2721 "Severity": "non_error", 2722 "ActionFlags": ["report"], 2723 "EventType": "env_normal", 2724 2725 "SRC": { 2726 "ReasonCode": "0x280B", 2727 "Words6To9": {} 2728 }, 2729 2730 "Documentation": { 2731 "Description": "An altitude sensor is under its warning threshold.", 2732 "Message": "An altitude sensor is under its warning threshold.", 2733 "Notes": [ 2734 "The virtual altitude sensor is under its warning threshold value", 2735 " and a symbolic FRU will be added." 2736 ] 2737 } 2738 }, 2739 2740 { 2741 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 2742 "Subsystem": "cec_tod", 2743 "ComponentID": "0x2800", 2744 "Severity": "predictive", 2745 "ActionFlags": ["service_action", "report"], 2746 2747 "SRC": { 2748 "ReasonCode": "0x280C", 2749 "Words6To9": {} 2750 }, 2751 2752 "CalloutsUsingAD": { 2753 "ADName": "SENSOR_NAME", 2754 "CalloutsWithTheirADValues": [ 2755 { 2756 "ADValue": "/xyz/openbmc_project/sensors/voltage/Battery_Voltage", 2757 "Callouts": [ 2758 { 2759 "System": "ibm,rainier", 2760 "CalloutList": [ 2761 { 2762 "Priority": "high", 2763 "LocCode": "P0-E0" 2764 } 2765 ] 2766 }, 2767 { 2768 "System": "ibm,everest", 2769 "CalloutList": [ 2770 { 2771 "Priority": "high", 2772 "LocCode": "P0-C0-E0" 2773 } 2774 ] 2775 } 2776 ] 2777 } 2778 ] 2779 }, 2780 2781 "Documentation": { 2782 "Description": "A voltage sensor went below its critical low threshold.", 2783 "Message": "A voltage sensor went below its critical low threshold." 2784 } 2785 }, 2786 2787 { 2788 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 2789 "Subsystem": "cec_tod", 2790 "ComponentID": "0x2800", 2791 "Severity": "non_error", 2792 "ActionFlags": ["report"], 2793 2794 "SRC": { 2795 "ReasonCode": "0x280D", 2796 "Words6To9": {} 2797 }, 2798 2799 "Documentation": { 2800 "Description": "A voltage sensor is over its critical low threshold.", 2801 "Message": "A voltage sensor is over its critical low threshold." 2802 } 2803 }, 2804 2805 { 2806 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 2807 "Subsystem": "cec_vpd", 2808 "ComponentID": "0x4000", 2809 2810 "SRC": { 2811 "ReasonCode": "0x4000", 2812 "Words6To9": 2813 { 2814 "6": 2815 { 2816 "Description": "Errno of the failure.", 2817 "AdditionalDataPropSource": "CALLOUT_ERRNO" 2818 } 2819 } 2820 }, 2821 2822 "Documentation": { 2823 "Description": "A path access error ocurred", 2824 "Message": "An EEPROM path access error occurred.", 2825 "Notes": [ 2826 "This error occurs when parser is unable to access", 2827 "EEPROM path. Errno and device path are captured as", 2828 "additional data." 2829 ] 2830 } 2831 }, 2832 2833 { 2834 "Name": "com.ibm.VPD.Error.InvalidVPD", 2835 "Subsystem": "cec_vpd", 2836 "ComponentID": "0x4000", 2837 2838 "SRC": { 2839 "ReasonCode": "0x4001", 2840 "Words6To9": 2841 { 2842 } 2843 }, 2844 2845 "Documentation": { 2846 "Description": "Invalid VPD data.", 2847 "Message": "A VPD data exception occurred.", 2848 "Notes": [ 2849 "This error occurs when VPD data is found to be", 2850 "invalid. This can be when VPD file is missing out", 2851 "mandatory records.Inventory path is captured in", 2852 "additional data." 2853 ] 2854 } 2855 }, 2856 2857 { 2858 "Name": "com.ibm.VPD.Error.EccCheckFailed", 2859 "Subsystem": "cec_vpd", 2860 "ComponentID": "0x4000", 2861 2862 "SRC": { 2863 "ReasonCode": "0x4002", 2864 "Words6To9": 2865 { 2866 } 2867 }, 2868 2869 "Documentation": { 2870 "Description": "Invalid VPD ecc data.", 2871 "Message": "A VPD ecc exception occurred.", 2872 "Notes": [ 2873 "This error occurs when VPD ecc check fails for the FRU.", 2874 "Inventory path for the failed FRU is captured in additonal", 2875 "data." 2876 ] 2877 } 2878 }, 2879 2880 { 2881 "Name": "com.ibm.VPD.Error.InvalidJson", 2882 "Subsystem": "cec_vpd", 2883 "ComponentID": "0x4000", 2884 2885 "SRC": { 2886 "ReasonCode": "0x4003", 2887 "Words6To9": 2888 { 2889 } 2890 }, 2891 2892 "Documentation": { 2893 "Description": "Invalid Json", 2894 "Message": "A Json failure occurred.", 2895 "Notes": [ 2896 "This error occurs when parser fails to access", 2897 "Json file or there is any issue with Json data.", 2898 "Failed Json path and cause of failure is captured", 2899 "in additional data." 2900 ] 2901 } 2902 }, 2903 2904 { 2905 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 2906 "Subsystem": "cec_vpd", 2907 "ComponentID": "0x4000", 2908 2909 "SRC": { 2910 "ReasonCode": "0x4004", 2911 "Words6To9": 2912 { 2913 } 2914 }, 2915 2916 "Documentation": { 2917 "Description": "System VPD restore failed", 2918 "Message": "A system VPD restoration error occurred.", 2919 "Notes": [ 2920 "This error occurs when restoring of system VPD fails.", 2921 "The FRU path and reason for failure is captured in", 2922 "additional data." 2923 ] 2924 } 2925 }, 2926 2927 { 2928 "Name": "com.ibm.VPD.Error.DbusFailure", 2929 "Subsystem": "cec_vpd", 2930 "ComponentID": "0x4000", 2931 2932 "SRC": { 2933 "ReasonCode": "0x4005", 2934 "Words6To9": 2935 { 2936 } 2937 }, 2938 2939 "Documentation": { 2940 "Description": "Dbus exception", 2941 "Message": "A Dbus internal error occurred.", 2942 "Notes": [ 2943 "This error occurs when Dbus operation fails.", 2944 "Exceptions details are captured in additonal", 2945 "data." 2946 ] 2947 } 2948 }, 2949 2950 { 2951 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 2952 "Subsystem": "cec_sp_hostboot_iface", 2953 2954 "SRC": 2955 { 2956 "ReasonCode": "0xC101", 2957 "Words6To9": 2958 { 2959 } 2960 }, 2961 2962 "Documentation": 2963 { 2964 "Description": "Host did not respond within the watchdog timeout interval", 2965 "Message": "Host did not respond before the watchdog timeout interval expired", 2966 "Notes": [ 2967 "Host did not respond before the expiry of the watchdog timeout interval.", 2968 "Collecting hostboot dump." 2969 ] 2970 } 2971 } 2972 2973 ] 2974} 2975