1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 "Severity": "non_error", 8 9 "SRC": 10 { 11 "ReasonCode": "0x1001", 12 "Words6To9": 13 { 14 "6": 15 { 16 "Description": "Timeout in ms", 17 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 18 } 19 } 20 }, 21 22 "Documentation": 23 { 24 "Description": "This is a generic timeout error", 25 "Message": "An operation timed out", 26 "Notes": [ 27 "The journal should contain more information" 28 ] 29 } 30 }, 31 32 { 33 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 34 "Subsystem": "bmc_firmware", 35 "Severity": "non_error", 36 37 "SRC": 38 { 39 "ReasonCode": "0x1002", 40 "Words6To9": 41 { 42 } 43 }, 44 45 "Documentation": 46 { 47 "Description": "BMC code had a generic internal failure", 48 "Message": "An application had an internal failure", 49 "Notes": [ 50 "The journal should contain more information" 51 ] 52 } 53 }, 54 55 { 56 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 57 "Subsystem": "user_error", 58 "Severity": "non_error", 59 60 "SRC": 61 { 62 "ReasonCode": "0x1003", 63 "Words6To9": 64 { 65 } 66 }, 67 68 "Documentation": 69 { 70 "Description": "BMC code was given an invalid argument", 71 "Message": "Code was given an invalid argument", 72 "Notes": [ 73 "The journal should contain more information" 74 ] 75 } 76 }, 77 { 78 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 79 "Subsystem": "user_error", 80 "Severity": "non_error", 81 82 "SRC": 83 { 84 "ReasonCode": "0x1004", 85 "Words6To9": 86 { 87 } 88 }, 89 90 "Documentation": 91 { 92 "Description": "An operation failed due to insufficient permission", 93 "Message": "An operation failed due to unsufficient permission", 94 "Notes": [ 95 "The journal should contain more information" 96 ] 97 } 98 }, 99 100 { 101 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 102 "Subsystem": "user_error", 103 "Severity": "non_error", 104 105 "SRC": 106 { 107 "ReasonCode": "0x1005", 108 "Words6To9": 109 { 110 } 111 }, 112 113 "Documentation": 114 { 115 "Description": "An operation failed because it isn't allowed", 116 "Message": "An operation failed because it isn't allowed", 117 "Notes": [ 118 "The journal should contain more information" 119 ] 120 } 121 }, 122 123 { 124 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 125 "Subsystem": "user_error", 126 "Severity": "non_error", 127 128 "SRC": 129 { 130 "ReasonCode": "0x1006", 131 "Words6To9": 132 { 133 } 134 }, 135 136 "Documentation": 137 { 138 "Description": "The server's CA certificate has not been provided", 139 "Message": "The server's CA certificate has not been provided" 140 } 141 }, 142 143 { 144 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 145 "Subsystem": "cec_i2c", 146 147 "SRC": 148 { 149 "ReasonCode": "0x1007", 150 "Words6To9": 151 { 152 "6": 153 { 154 "Description": "errno of the failure", 155 "AdditionalDataPropSource": "CALLOUT_ERRNO" 156 } 157 } 158 }, 159 160 "Documentation": 161 { 162 "Description": "Sensor device read failure", 163 "Message": "There was a failure when reading a sensor device", 164 "Notes": [ 165 "The severity is set by the creator.", 166 "The action flags are set automatically by the code.", 167 "Callouts added based on CALLOUT_DEVICE_PATH." 168 ] 169 } 170 }, 171 172 { 173 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 174 "Subsystem": "cec_i2c", 175 176 "SRC": 177 { 178 "ReasonCode": "0x1008", 179 "Words6To9": 180 { 181 "6": 182 { 183 "Description": "errno of the failure", 184 "AdditionalDataPropSource": "CALLOUT_ERRNO" 185 } 186 } 187 }, 188 189 "Documentation": 190 { 191 "Description": "Device read failure", 192 "Message": "There was a failure when reading a hardware device", 193 "Notes": [ 194 "The severity is set by the creator.", 195 "The action flags are set automatically by the code.", 196 "Callouts added based on CALLOUT_DEVICE_PATH." 197 ] 198 } 199 }, 200 201 { 202 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 203 "Subsystem": "cec_i2c", 204 205 "SRC": 206 { 207 "ReasonCode": "0x1009", 208 "Words6To9": 209 { 210 "6": 211 { 212 "Description": "errno of the failure", 213 "AdditionalDataPropSource": "CALLOUT_ERRNO" 214 } 215 } 216 }, 217 218 "Documentation": 219 { 220 "Description": "Device write failure", 221 "Message": "There was a failure when writing to a hardware device", 222 "Notes": [ 223 "The severity is set by the creator.", 224 "The action flags are set automatically by the code.", 225 "Callouts added based on CALLOUT_DEVICE_PATH" 226 ] 227 } 228 }, 229 230 { 231 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 232 "Subsystem": "cec_i2c", 233 234 "SRC": 235 { 236 "ReasonCode": "0x100A", 237 "Words6To9": 238 { 239 "6": 240 { 241 "Description": "errno of the failure", 242 "AdditionalDataPropSource": "CALLOUT_ERRNO" 243 } 244 } 245 }, 246 247 "Documentation": 248 { 249 "Description": "Device write failure", 250 "Message": "There was a failure when writing to a hardware device", 251 "Notes": [ 252 "The severity is set by the creator.", 253 "The action flags are set automatically by the code.", 254 "Callouts added based on CALLOUT_DEVICE_PATH" 255 ] 256 } 257 }, 258 259 { 260 "Name": "xyz.openbmc_project.Common.File.Error.Write", 261 "Subsystem": "bmc_firmware", 262 "ComponentID": "0x1000", 263 "SRC": 264 { 265 "ReasonCode": "0x100B", 266 "Words6To9": 267 { 268 } 269 }, 270 271 "Callouts": [ 272 { 273 "CalloutList": [ 274 { "Priority": "high", "Procedure": "bmc_code" } 275 ] 276 } 277 ], 278 279 "Documentation": 280 { 281 "Description": "Failed to write to a file", 282 "Message": "Failed to write to a file", 283 "Notes": [ 284 "The severity is set by the creator.", 285 "The journal should contain more information" 286 ] 287 } 288 }, 289 290 { 291 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 292 "Subsystem": "bmc_firmware", 293 "Severity": "non_error", 294 295 "SRC": 296 { 297 "ReasonCode": "0x2001", 298 "Words6To9": 299 { 300 "6": 301 { 302 "Description": "The bad PEL ID", 303 "AdditionalDataPropSource": "BAD_ID" 304 } 305 } 306 }, 307 308 "Documentation": 309 { 310 "Description": "The BMC sent the host a malformed PEL", 311 "Message": "The BMC sent the host a malformed PEL", 312 "Notes": [ 313 "The host firmware rejected that PEL." 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.BadHostPEL", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2002", 326 "Words6To9": 327 { 328 "6": 329 { 330 "Description": "The PLID of the invalid PEL", 331 "AdditionalDataPropSource": "PLID" 332 }, 333 "7": 334 { 335 "Description": "The corresponding OpenBMC event log ID", 336 "AdditionalDataPropSource": "OBMC_LOG_ID" 337 }, 338 "8": 339 { 340 "Description": "The size of the invalid PEL", 341 "AdditionalDataPropSource": "PEL_SIZE" 342 } 343 } 344 }, 345 346 "Callouts": [ 347 { 348 "CalloutList": [ 349 { "Priority": "high", "Procedure": "bmc_code" } 350 ] 351 } 352 ], 353 354 "Documentation": 355 { 356 "Description": "The host sent the BMC an invalid PEL", 357 "Message": "The host sent the BMC an invalid PEL", 358 "Notes": [ 359 ] 360 } 361 }, 362 363 { 364 "Name": "org.open_power.Logging.Error.TestError1", 365 "Subsystem": "platform_firmware", 366 "Severity": "unrecoverable", 367 368 "SRC": 369 { 370 "ReasonCode": "0x2003", 371 "Words6To9": 372 { 373 } 374 }, 375 376 "Callouts": [ 377 { 378 "CalloutList": [ 379 {"Priority": "high", "Procedure": "bmc_code"}, 380 {"Priority": "medium", "SymbolicFRU": "service_docs"} 381 ] 382 } 383 ], 384 385 "Documentation": 386 { 387 "Description": "An error for testing", 388 "Message": "This is a test error" 389 } 390 }, 391 392 { 393 "Name": "xyz.openbmc_project.Logging.Error.Default", 394 "Subsystem": "other_na", 395 396 "SRC": 397 { 398 "ReasonCode": "0x2004", 399 "Words6To9": 400 { 401 } 402 }, 403 404 "Callouts": [ 405 { 406 "CalloutList": [ 407 { "Priority": "high", "Procedure": "bmc_code" } 408 ] 409 } 410 ], 411 412 "Documentation": 413 { 414 "Description": "This entry is used when no other matching entry is found", 415 "Message": "Unknown (Original event not in message registry)", 416 "Notes": [ 417 "This is used when the actual error name isn't found in ", 418 "the registry. The original error name will be stored ", 419 "in the UserData section that contains the AdditionalData ", 420 "properties using the key ERROR_NAME.", 421 "This error may contain callouts if the creator passed ", 422 "them in.", 423 "The severity is set by the creator.", 424 "If this error is seen, then a code change needs to be ", 425 "made to add the missing error entry to this registry." 426 ] 427 } 428 }, 429 430 { 431 "Name": "org.open_power.Logging.Error.TestError2", 432 "Subsystem": "bmc_firmware", 433 "Severity": "recovered", 434 "ActionFlags": ["report"], 435 436 "SRC": 437 { 438 "ReasonCode": "0x2005", 439 "Words6To9": 440 { 441 } 442 }, 443 444 "Callouts": [ 445 { 446 "CalloutList": [ 447 { "Priority": "high", "LocCode": "P0" } 448 ] 449 } 450 ], 451 452 "Documentation": 453 { 454 "Description": "An error for testing", 455 "Message": "This is a test recoverable error", 456 "Notes": [ 457 "This error is not created by BMC code and is ", 458 "only used for error injection tests." 459 ] 460 } 461 }, 462 463 { 464 "Name": "org.open_power.Logging.Error.TestError3", 465 "Subsystem": "bmc_firmware", 466 "Severity": "predictive", 467 468 "SRC": 469 { 470 "ReasonCode": "0x2006", 471 "Words6To9": 472 { 473 } 474 }, 475 476 "Documentation": 477 { 478 "Description": "This is an error used for testing only", 479 "Message": "This is a test predictive error", 480 "Notes": [ 481 "This error is not created by BMC code and is ", 482 "only used for error injection tests." 483 ] 484 } 485 }, 486 487 { 488 "Name": "org.open_power.PHAL.Error.Boot", 489 "Subsystem": "cec_hardware", 490 "ComponentID": "0x3000", 491 492 "SRC": 493 { 494 "ReasonCode": "0x3001", 495 "Words6To9": 496 { 497 } 498 }, 499 500 "Documentation": 501 { 502 "Description": "Failure occurred during boot process", 503 "Message": "Failure occurred during boot process", 504 "Notes": [ 505 "Debug traces will be captured in AdditionalData section" 506 ] 507 } 508 }, 509 510 { 511 "Name": "org.open_power.PHAL.Error.PrePowerOff", 512 "Subsystem": "cec_hardware", 513 "ComponentID": "0x3000", 514 515 "SRC": 516 { 517 "ReasonCode": "0x3002", 518 "Words6To9": 519 { 520 } 521 }, 522 523 "Documentation": 524 { 525 "Description": "Failure occurred during PHAL pre-poweroff operations", 526 "Message": "Failure occurred during PHAL pre-poweroff operations", 527 "Notes": [ 528 "Severity needs to be set based on needs for this registry.", 529 "FFDC (First Failure Data Collection) will be collected ", 530 "and added into PEL." 531 ] 532 } 533 }, 534 535 { 536 "Name": "org.open_power.PHAL.Error.devtreeSync", 537 "Subsystem": "cec_hardware", 538 "ComponentID": "0x3000", 539 "Severity": "unrecoverable", 540 541 "SRC": 542 { 543 "ReasonCode": "0x3003", 544 "Words6To9": 545 { 546 } 547 }, 548 549 "Documentation": 550 { 551 "Description": "Failure occurred during PHAL devtree sync ", 552 "Message": "Failure occurred during PHAL devtree sync", 553 "Notes": [ 554 "The journal should contain more information" 555 ] 556 } 557 }, 558 559 { 560 "Name": "org.open_power.PHAL.Error.devtreeBackup", 561 "Subsystem": "cec_hardware", 562 "ComponentID": "0x3000", 563 "Severity": "unrecoverable", 564 565 "SRC": 566 { 567 "ReasonCode": "0x3004", 568 "Words6To9": 569 { 570 } 571 }, 572 573 "Documentation": 574 { 575 "Description": "Failure occurred during PHAL devtree backup ", 576 "Message": "Failure occurred during PHAL devtree backup", 577 "Notes": [ 578 "The journal should contain more information" 579 ] 580 } 581 }, 582 583 { 584 "Name": "org.open_power.PHAL.Error.HostRunning", 585 "Subsystem": "cec_sp_hyp_iface", 586 "ComponentID": "0x3000", 587 588 "SRC": 589 { 590 "ReasonCode": "0x3005", 591 "Words6To9": 592 { 593 } 594 }, 595 596 "Documentation": 597 { 598 "Description": "Host did not respond to BMC after a BMC reset", 599 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 600 "Notes": [ 601 "System will be left in its current state to ensure host ", 602 "is not unexpectedly taken down. There is most likely an ", 603 "issue in the software or hardware communication path ", 604 "between the BMC and the Host firmware.", 605 "A BMC dump will be collected with relevant FFDC." 606 ] 607 } 608 }, 609 610 { 611 "Name": "org.open_power.PHAL.Error.devtreeReinit", 612 "Subsystem": "cec_hardware", 613 "ComponentID": "0x3000", 614 "Severity": "unrecoverable", 615 616 "SRC": 617 { 618 "ReasonCode": "0x3006", 619 "Words6To9": 620 { 621 } 622 }, 623 624 "Documentation": 625 { 626 "Description": "Failure re-initializing BMC to Host data structure", 627 "Message": "Failure occurred during re-initializing BMC to Host data structure", 628 "Notes": [ 629 "The journal should contain more information" 630 ] 631 } 632 }, 633 634 { 635 "Name": "org.open_power.PHAL.Error.NonFunctionalBootProc", 636 "Subsystem": "cec_hardware", 637 "ComponentID": "0x3000", 638 "Severity": "unrecoverable", 639 640 "SRC": 641 { 642 "ReasonCode": "0x3007", 643 "Words6To9": 644 { 645 } 646 }, 647 648 "Documentation": 649 { 650 "Description": "Non functional boot processor", 651 "Message": "Non functional boot processor", 652 "Notes": [ 653 "BMC firmware couldn't find functional primary processor", 654 "required to boot the host", 655 "Debug traces will be captured in AdditionalData section" 656 ] 657 } 658 }, 659 660 { 661 "Name": "org.open_power.PHAL.Error.MPReboot", 662 "Subsystem": "cec_hardware", 663 "ComponentID": "0x3000", 664 "Severity": "unrecoverable", 665 666 "SRC": 667 { 668 "ReasonCode": "0x3008", 669 "Words6To9": 670 { 671 } 672 }, 673 674 "Callouts": [ 675 { 676 "CalloutList": [{"Priority": "high", "Procedure": "bmc_code" } 677 ] 678 } 679 ], 680 681 "Documentation": 682 { 683 "Description": "Error during memory preserving reboot", 684 "Message": "Error during memory preserving reboot", 685 "Notes": [ 686 "Software error occured during memory preserving reboot" 687 ] 688 } 689 } 690, 691 { 692 "Name": "org.open_power.PHAL.Error.SpareClock", 693 "Subsystem": "cec_hardware", 694 "ComponentID": "0x3000", 695 "Severity": "non_error", 696 697 "SRC": 698 { 699 "ReasonCode": "0x3009", 700 "Words6To9": 701 { 702 } 703 }, 704 705 "Callouts": [ 706 { 707 "System": "ibm,rainier", 708 "CalloutList": [ 709 { 710 "Priority": "high", 711 "LocCode": "P0" 712 }, 713 { 714 "Priority": "low", 715 "LocCode": "P0-C15" 716 } 717 ] 718 }, 719 { 720 "System": "ibm,everest", 721 "CalloutList": [ 722 { 723 "Priority": "high", 724 "LocCode": "P0" 725 }, 726 { 727 "Priority": "low", 728 "LocCode": "P0-C61" 729 } 730 ] 731 } 732 ], 733 734 "Documentation": 735 { 736 "Description": "Error during Spare clock initialisation", 737 "Message": "Error during Spare clock initialisation", 738 "Notes": [ 739 "The clock symbolic FRU in the CalloutList provides the", 740 "reference to clock unit." 741 ] 742 } 743 }, 744 745 { 746 "Name": "org.open_power.PHAL.Info.ClockDailyLog", 747 "Subsystem": "cec_clocks", 748 "ComponentID": "0x3000", 749 "Severity": "non_error", 750 "ActionFlags": [ "report", "call_home" ], 751 752 "SRC": 753 { 754 "ReasonCode": "0x300A", 755 "Words6To9": 756 { 757 } 758 }, 759 760 "Documentation": 761 { 762 "Description": "Informational error to house clock debug info", 763 "Message": "Informational error to house clock debug info", 764 "Notes": [ 765 "User data includes processor and clock register state information." 766 ] 767 } 768 }, 769 770 { 771 "Name": "org.open_power.PHAL.Error.GuardPartitionAccess", 772 "Subsystem": "bmc_firmware", 773 "ComponentID": "0x3000", 774 "Severity": "predictive", 775 776 "SRC": 777 { 778 "ReasonCode": "0x300B", 779 "Words6To9": 780 { 781 } 782 }, 783 784 "Callouts": [ 785 { 786 "CalloutList": [ 787 { "Priority": "high", "Procedure": "bmc_code" } 788 ] 789 } 790 ], 791 792 "Documentation": 793 { 794 "Description": "Guard partition access failure", 795 "Message": "Guard partition access failure", 796 "Notes": [ 797 "User data and journal should contain more information" 798 ] 799 } 800 }, 801 802 { 803 "Name": "org.open_power.OCC.Firmware.PresenceMismatch", 804 "Subsystem": "bmc_firmware", 805 "ComponentID": "0x2600", 806 "Severity": "predictive", 807 808 "SRC": 809 { 810 "ReasonCode": "0x2681", 811 "Words6To9": 812 { 813 } 814 }, 815 816 "Callouts": [ 817 { 818 "CalloutList": [ 819 { "Priority": "medium", "Procedure": "bmc_code" } 820 ] 821 } 822 ], 823 824 "Documentation": 825 { 826 "Description": "OCC presence mismatch", 827 "Message": "BMC firmware detected incorrect number of OCCs", 828 "Notes": [ 829 "The number of OCCs detected by the BMC does not match the number of OCCs detected by the OCC.", 830 "The BMC requests that the OCC reset." 831 ] 832 } 833 }, 834 835 { 836 "Name": "org.open_power.OCC.Device.SafeState", 837 "Subsystem": "processor_chip", 838 "ComponentID": "0x2600", 839 "Severity": "non_error", 840 841 "SRC": 842 { 843 "ReasonCode": "0x2682", 844 "Words6To9": 845 { 846 } 847 }, 848 849 "Documentation": 850 { 851 "Description": "OCC safe state", 852 "Message": "OCC in safe state while active for one minute", 853 "Notes": [ 854 "The BMC detected that the OCC was in safe state for one minute while active.", 855 "The BMC requests that the OCC reset." 856 ] 857 } 858 }, 859 860 { 861 "Name": "org.open_power.OCC.Device.ReadFailure", 862 "Subsystem": "cec_chip_iface", 863 "ComponentID": "0x2600", 864 "Severity": "predictive", 865 866 "SRC": 867 { 868 "ReasonCode": "0x2683", 869 "Words6To9": 870 { 871 } 872 }, 873 874 "Documentation": 875 { 876 "Description": "OCC communication failure", 877 "Message": "BMC failed to communicate with the OCC", 878 "Notes": [ 879 "The BMC failed to communicate with the OCC and retried three times.", 880 "The BMC requests that the OCC reset." 881 ] 882 } 883 }, 884 885 { 886 "Name": "org.open_power.HardwareIsolation.Error", 887 "Subsystem": "cec_hardware", 888 "ComponentID": "0x3100", 889 890 "SRC": 891 { 892 "ReasonCode": "0x3101", 893 "Words6To9": 894 { 895 } 896 }, 897 898 "Documentation": 899 { 900 "Description": "Failure occurred during hardware isolation operations", 901 "Message": "Failure occurred during hardware isolation operations", 902 "Notes": [ 903 "Severity needs to be set based on needs for this registry.", 904 "Debug traces will be captured in AdditionalData section" 905 ] 906 } 907 }, 908 909 { 910 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 911 "Subsystem": "cec_sp_hostboot_iface", 912 "ComponentID": "0x3400", 913 "SRC": 914 { 915 "ReasonCode": "0x3401", 916 "Words6To9": 917 { 918 } 919 }, 920 "Documentation": 921 { 922 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 923 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 924 "Notes": [ 925 "System will follow recovery policy, resulting in this ", 926 "error and most likely a a reboot of the host. The issue ", 927 "is most likely the result of the BMC rebooting while the ", 928 "host was booting and in a state where it still needed ", 929 "the BMC to complete its boot." 930 ] 931 } 932 }, 933 934 { 935 "Name": "xyz.openbmc_project.State.ChassisPowerBad", 936 "Subsystem": "input_power_source", 937 "ComponentID": "0x3400", 938 "SRC": 939 { 940 "ReasonCode": "0x3402", 941 "Words6To9": 942 { 943 } 944 }, 945 "Callouts": [ 946 { 947 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 948 } 949 ], 950 "Documentation": 951 { 952 "Description": "Chassis input power is in a bad state", 953 "Message": "Chassis input power is in a bad state, look for other logs with more details", 954 "Notes": [ 955 "The system is most likely in a limited power situation. ", 956 "There is enough power for the BMC to operate but not the ", 957 "CEC hardware. Check for UPS or brownout logs." 958 ] 959 } 960 }, 961 962 { 963 "Name": "xyz.openbmc_project.State.PinholeReset", 964 "Subsystem": "cec_op_panel", 965 "ComponentID": "0x3400", 966 "SRC": 967 { 968 "ReasonCode": "0x3403", 969 "Words6To9": 970 { 971 } 972 }, 973 "Documentation": 974 { 975 "Description": "User initiated a pinhole reset via the op-panel", 976 "Message": "User initiated a pinhole reset via the op-panel", 977 "Notes": [ 978 "This is a notification log to record the fact that a ", 979 "pinhole reset was performed on the BMC, resulting in a ", 980 "hard reset of the BMC." 981 ] 982 } 983 }, 984 985 { 986 "Name": "xyz.openbmc_project.State.Error.CriticalServiceFailure", 987 "Subsystem": "bmc_firmware", 988 "ComponentID": "0x3400", 989 "SRC": 990 { 991 "ReasonCode": "0x3404", 992 "Words6To9": 993 { 994 } 995 }, 996 "Callouts": [ 997 { 998 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 999 } 1000 ], 1001 "Documentation": 1002 { 1003 "Description": "A critical BMC application has failed on the system", 1004 "Message": "A critical BMC application has failed on the system, the BMC is in an undefined state", 1005 "Notes": [ 1006 "As a part of generating this error log, a BMC dump has ", 1007 "also been generated. Please collect this dump if possible. ", 1008 "The BMC state is undefined but basic services could still ", 1009 "be available. Usually an AC cycle of the entire system is ", 1010 "the best recovery option from this error." 1011 ] 1012 } 1013 }, 1014 1015 { 1016 "Name": "xyz.openbmc_project.State.Error.SecurityCheckFail", 1017 "Subsystem": "bmc_firmware", 1018 "ComponentID": "0x3400", 1019 "SRC": 1020 { 1021 "ReasonCode": "0x3405", 1022 "Words6To9": 1023 { 1024 } 1025 }, 1026 "Callouts": [ 1027 { 1028 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1029 } 1030 ], 1031 "Documentation": 1032 { 1033 "Description": "A firmware security check has failed", 1034 "Message": "A firmware security check has failed, most likely something is not configured correctly", 1035 "Notes": [ 1036 "This log is only generated in the manufacturing ", 1037 "environment and it indicates that something has not ", 1038 "been configured correctly. Use the data in the PEL to ", 1039 "determine what that is." 1040 ] 1041 } 1042 }, 1043 1044 { 1045 "Name": "xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure", 1046 "Subsystem": "bmc_firmware", 1047 "ComponentID": "0x3400", 1048 "SRC": 1049 { 1050 "ReasonCode": "0x3406", 1051 "Words6To9": 1052 { 1053 } 1054 }, 1055 "Callouts": [ 1056 { 1057 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1058 } 1059 ], 1060 "Documentation": 1061 { 1062 "Description": "The system has failed to reach BMC Ready state", 1063 "Message": "The system has failed to reach BMC Ready state, look for other errors", 1064 "Notes": [ 1065 "This log indicates a critical BMC application required ", 1066 "for the BMC to reach Ready state has failed to start ", 1067 "successfully. Look in the log for other errors indicating ", 1068 "what has failed." 1069 ] 1070 } 1071 }, 1072 1073 { 1074 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOnFailure", 1075 "Subsystem": "bmc_firmware", 1076 "ComponentID": "0x3400", 1077 "SRC": 1078 { 1079 "ReasonCode": "0x3407", 1080 "Words6To9": 1081 { 1082 } 1083 }, 1084 "Callouts": [ 1085 { 1086 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1087 } 1088 ], 1089 "Documentation": 1090 { 1091 "Description": "The system has failed to reach chassis power on state", 1092 "Message": "The system has failed to reach chassis power on state, look for other errors", 1093 "Notes": [ 1094 "This log indicates a critical BMC application required ", 1095 "for the BMC to power on the chassis has failed to start ", 1096 "successfully. Look in the log for other errors indicating ", 1097 "what has failed." 1098 ] 1099 } 1100 }, 1101 1102 { 1103 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOffFailure", 1104 "Subsystem": "bmc_firmware", 1105 "ComponentID": "0x3400", 1106 "SRC": 1107 { 1108 "ReasonCode": "0x3408", 1109 "Words6To9": 1110 { 1111 } 1112 }, 1113 "Callouts": [ 1114 { 1115 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1116 } 1117 ], 1118 "Documentation": 1119 { 1120 "Description": "The system has failed to reach chassis power off state", 1121 "Message": "The system has failed to reach chassis power off state, look for other errors", 1122 "Notes": [ 1123 "This log indicates a critical BMC application required ", 1124 "for the BMC to power off the chassis has failed to start ", 1125 "successfully. Look in the log for other errors indicating ", 1126 "what has failed." 1127 ] 1128 } 1129 }, 1130 1131 { 1132 "Name": "xyz.openbmc_project.State.Host.Error.HostStartFailure", 1133 "Subsystem": "bmc_firmware", 1134 "ComponentID": "0x3400", 1135 "SRC": 1136 { 1137 "ReasonCode": "0x3409", 1138 "Words6To9": 1139 { 1140 } 1141 }, 1142 "Callouts": [ 1143 { 1144 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1145 } 1146 ], 1147 "Documentation": 1148 { 1149 "Description": "The system has failed to start the host firmware", 1150 "Message": "The system has failed to start the host firmware, look for other errors", 1151 "Notes": [ 1152 "This log indicates a critical BMC application required ", 1153 "for the BMC to start the host has failed to start ", 1154 "successfully. Look in the log for other errors indicating ", 1155 "what has failed." 1156 ] 1157 } 1158 }, 1159 1160 { 1161 "Name": "xyz.openbmc_project.State.Host.Error.HostStartMinFailure", 1162 "Subsystem": "bmc_firmware", 1163 "ComponentID": "0x3400", 1164 "SRC": 1165 { 1166 "ReasonCode": "0x3410", 1167 "Words6To9": 1168 { 1169 } 1170 }, 1171 "Callouts": [ 1172 { 1173 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1174 } 1175 ], 1176 "Documentation": 1177 { 1178 "Description": "The system has failed to start the host firmware", 1179 "Message": "The system has failed to start the host firmware, look for other errors", 1180 "Notes": [ 1181 "This log indicates a critical BMC application required ", 1182 "for the BMC to start the host has failed to start ", 1183 "successfully. Look in the log for other errors indicating ", 1184 "what has failed." 1185 ] 1186 } 1187 }, 1188 1189 { 1190 "Name": "xyz.openbmc_project.State.Host.Error.HostShutdownFailure", 1191 "Subsystem": "bmc_firmware", 1192 "ComponentID": "0x3400", 1193 "SRC": 1194 { 1195 "ReasonCode": "0x3411", 1196 "Words6To9": 1197 { 1198 } 1199 }, 1200 "Callouts": [ 1201 { 1202 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1203 } 1204 ], 1205 "Documentation": 1206 { 1207 "Description": "The system has failed to shutdown the host firmware", 1208 "Message": "The system has failed to shutdown the host firmware, look for other errors", 1209 "Notes": [ 1210 "This log indicates a critical BMC application required ", 1211 "to shutdown the host firmware has failed to start ", 1212 "successfully. Look in the log for other errors indicating ", 1213 "what has failed." 1214 ] 1215 } 1216 }, 1217 1218 { 1219 "Name": "xyz.openbmc_project.State.Host.Error.HostStopFailure", 1220 "Subsystem": "bmc_firmware", 1221 "ComponentID": "0x3400", 1222 "SRC": 1223 { 1224 "ReasonCode": "0x3412", 1225 "Words6To9": 1226 { 1227 } 1228 }, 1229 "Callouts": [ 1230 { 1231 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1232 } 1233 ], 1234 "Documentation": 1235 { 1236 "Description": "The system has failed to stop the host firmware", 1237 "Message": "The system has failed to stop the host firmware, look for other errors", 1238 "Notes": [ 1239 "This log indicates a critical BMC application required ", 1240 "to stop the host firmware has failed to start ", 1241 "successfully. Look in the log for other errors indicating ", 1242 "what has failed." 1243 ] 1244 } 1245 }, 1246 1247 { 1248 "Name": "xyz.openbmc_project.State.Host.Error.HostRebootFailure", 1249 "Subsystem": "bmc_firmware", 1250 "ComponentID": "0x3400", 1251 "SRC": 1252 { 1253 "ReasonCode": "0x3413", 1254 "Words6To9": 1255 { 1256 } 1257 }, 1258 "Callouts": [ 1259 { 1260 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1261 } 1262 ], 1263 "Documentation": 1264 { 1265 "Description": "The system has failed to reboot the host firmware", 1266 "Message": "The system has failed to reboot the host firmware, look for other errors", 1267 "Notes": [ 1268 "This log indicates a critical BMC application required ", 1269 "to reboot the host firmware has failed to start ", 1270 "successfully. Look in the log for other errors indicating ", 1271 "what has failed." 1272 ] 1273 } 1274 }, 1275 1276 { 1277 "Name": "xyz.openbmc_project.State.Error.HostQuiesce", 1278 "Subsystem": "bmc_firmware", 1279 "ComponentID": "0x3400", 1280 "SRC": 1281 { 1282 "ReasonCode": "0x3414", 1283 "Words6To9": 1284 { 1285 } 1286 }, 1287 "Callouts": [ 1288 { 1289 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1290 } 1291 ], 1292 "Documentation": 1293 { 1294 "Description": "The host firmware has failed to boot", 1295 "Message": "The host firmware has failed to boot and has entered a Quiesce state. Look for other errors.", 1296 "Notes": [ 1297 "This log indicates that the host firmware has failed to ", 1298 "boot and all retries have been exhausted. There should be ", 1299 "other logs with more details on the boot failure reason. " 1300 ] 1301 } 1302 }, 1303 1304 { 1305 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 1306 "Subsystem": "processor_chip", 1307 "ComponentID": "0x3500", 1308 1309 "SRC": 1310 { 1311 "ReasonCode": "0x3500", 1312 "Words6To9": 1313 { 1314 "6": 1315 { 1316 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1317 "AdditionalDataPropSource": "SRC6" 1318 } 1319 } 1320 }, 1321 1322 "Documentation": 1323 { 1324 "Description": "chipop failure with SBE provided FFDC", 1325 "Message": "chipop request failure reported by SBE", 1326 "Notes": [ 1327 "The severity is set by the creator.", 1328 "Callouts added based on SBE provided FFDC.", 1329 "SBE provided additional debug data included as part of the", 1330 "additional user data section." 1331 ] 1332 } 1333 }, 1334 1335 { 1336 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 1337 "Subsystem": "processor_chip", 1338 "ComponentID": "0x3500", 1339 1340 "SRC": 1341 { 1342 "ReasonCode": "0x3501", 1343 "Words6To9": 1344 { 1345 "6": 1346 { 1347 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1348 "AdditionalDataPropSource": "SRC6" 1349 } 1350 } 1351 }, 1352 1353 "Callouts": [ 1354 { 1355 "CalloutList": [ 1356 { "Priority": "high", "Procedure": "next_level_support" } 1357 ] 1358 } 1359 ], 1360 1361 "Documentation": 1362 { 1363 "Description": "SBE chipop timeout", 1364 "Message": "chipop timeout reported during SBE communication", 1365 "Notes": [ 1366 "The severity is set by the creator.", 1367 "Check SBE Dump associated to this error to debug the failure." 1368 ] 1369 } 1370 }, 1371 1372 { 1373 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 1374 "Subsystem": "processor_chip", 1375 "ComponentID": "0x3500", 1376 1377 "SRC": 1378 { 1379 "ReasonCode": "0x3502", 1380 "Words6To9": 1381 { 1382 "6": 1383 { 1384 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1385 "AdditionalDataPropSource": "SRC6" 1386 }, 1387 "7": 1388 { 1389 "Description": "Value of SBE state", 1390 "AdditionalDataPropSource": "SRC7" 1391 } 1392 } 1393 }, 1394 1395 "Documentation": 1396 { 1397 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 1398 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 1399 "Notes": [ 1400 "The severity is set by the creator." 1401 ] 1402 } 1403 }, 1404 1405 { 1406 "Name": "org.open_power.Processor.Error.SbeBootFailure", 1407 "Subsystem": "processor_chip", 1408 "ComponentID": "0x3500", 1409 "ActionFlags": [ "service_action", "report", "call_home" ], 1410 1411 "SRC": 1412 { 1413 "ReasonCode": "0x3503", 1414 "Words6To9": 1415 { 1416 "6": 1417 { 1418 "Description": "[0:15] chip position", 1419 "AdditionalDataPropSource": "SRC6" 1420 } 1421 } 1422 }, 1423 1424 "Documentation": 1425 { 1426 "Description": "Boot failure with SBE provided FFDC", 1427 "Message": "Boot failure reported by SBE", 1428 "Notes": [ 1429 "The severity is set by the creator.", 1430 "Callouts added based on SBE provided FFDC.", 1431 "SBE provided additional debug data included as part of the", 1432 "additional user data section." 1433 ] 1434 } 1435 }, 1436 1437 { 1438 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 1439 "Subsystem": "processor_chip", 1440 "ComponentID": "0x3500", 1441 1442 "SRC": 1443 { 1444 "ReasonCode": "0x3504", 1445 "Words6To9": 1446 { 1447 } 1448 }, 1449 1450 "Callouts": [ 1451 { 1452 "System": "ibm,rainier", 1453 "CalloutList": [ 1454 { 1455 "Priority": "low", 1456 "LocCode": "P0" 1457 }, 1458 { 1459 "Priority": "low", 1460 "LocCode": "P0-C22" 1461 } 1462 ] 1463 }, 1464 { 1465 "System": "ibm,everest", 1466 "CalloutList": [ 1467 { 1468 "Priority": "low", 1469 "LocCode": "P0" 1470 }, 1471 { 1472 "Priority": "low", 1473 "LocCode": "P0-C96" 1474 } 1475 ] 1476 } 1477 ], 1478 1479 "Documentation": 1480 { 1481 "Description": "SBE Boot timeout", 1482 "Message": "timeout reported during SBE boot process", 1483 "Notes": [ 1484 "The severity is set by the creator.", 1485 "Check SBE Dump associated to this error to debug the failure." 1486 ] 1487 } 1488 }, 1489 1490 { 1491 "Name": "org.open_power.Attn.Error.Terminate", 1492 "Subsystem": "cec_hardware", 1493 "Severity": "non_error", 1494 1495 "SRC": 1496 { 1497 "ReasonCode": "0xD138", 1498 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 1499 "Words6To9": 1500 { 1501 } 1502 }, 1503 1504 "Documentation": 1505 { 1506 "Description": "Status shows TI special attention active", 1507 "Message": "TI special attention detected", 1508 "Notes": [ 1509 "This entry is for any TI special attention event ", 1510 "reported by the attention handler component" 1511 ] 1512 } 1513 }, 1514 1515 { 1516 "Name": "org.open_power.Attn.Error.Fail", 1517 "Subsystem": "bmc_firmware", 1518 "Severity": "unrecoverable_loss_of_function", 1519 1520 "SRC": 1521 { 1522 "ReasonCode": "0xD13E", 1523 "Words6To9": 1524 { 1525 "6": 1526 { 1527 "Description": "Error code from attention handler", 1528 "AdditionalDataPropSource": "ERROR_CODE" 1529 } 1530 } 1531 }, 1532 "Documentation": 1533 { 1534 "Description": "The attention handler encountered an error", 1535 "MessageArgSources" : ["SRCWord6"], 1536 "Message": "Attention handler error %1", 1537 "Notes": [ 1538 "Attention handler will provide error code" 1539 ] 1540 } 1541 }, 1542 1543 { 1544 "Name": "org.open_power.Attn.Error.Vital", 1545 "Subsystem": "processor_chip", 1546 "Severity": "critical", 1547 1548 "SRC": 1549 { 1550 "ReasonCode": "0xD16D", 1551 "Words6To9": 1552 { 1553 } 1554 }, 1555 1556 "Documentation": 1557 { 1558 "Description": "Status shows SBE vital attention active", 1559 "Message": "SBE vital attention detected", 1560 "Notes": [ 1561 "This entry is for any SBE vital attention event ", 1562 "reported by the attention handler component" 1563 ] 1564 } 1565 }, 1566 1567 { 1568 "Name": "org.open_power.HwDiags.Error.Checkstop", 1569 "PossibleSubsystems": [ 1570 "processor", "processor_fru", "processor_unit", "processor_bus", 1571 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1572 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1573 ], 1574 "Severity": "unrecoverable", 1575 "ActionFlags": [ "service_action", "report", "call_home" ], 1576 1577 "SRC": 1578 { 1579 "ReasonCode": "0xE510", 1580 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1581 "Words6To9": 1582 { 1583 "6": 1584 { 1585 "AdditionalDataPropSource": "SRC6" 1586 }, 1587 "7": 1588 { 1589 "AdditionalDataPropSource": "SRC7" 1590 }, 1591 "8": 1592 { 1593 "AdditionalDataPropSource": "SRC8" 1594 } 1595 } 1596 }, 1597 1598 "Documentation": 1599 { 1600 "Description": "A system checkstop attention has occurred", 1601 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1602 "Message": "Error Signature: %1 %2 %3" 1603 } 1604 }, 1605 1606 { 1607 "Name": "org.open_power.HwDiags.Error.Predictive", 1608 "PossibleSubsystems": [ 1609 "processor", "processor_fru", "processor_unit", "processor_bus", 1610 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1611 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1612 ], 1613 "Severity": "predictive", 1614 "ActionFlags": [ "service_action", "report", "call_home" ], 1615 1616 "SRC": 1617 { 1618 "ReasonCode": "0xE511", 1619 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1620 "Words6To9": 1621 { 1622 "6": 1623 { 1624 "AdditionalDataPropSource": "SRC6" 1625 }, 1626 "7": 1627 { 1628 "AdditionalDataPropSource": "SRC7" 1629 }, 1630 "8": 1631 { 1632 "AdditionalDataPropSource": "SRC8" 1633 } 1634 } 1635 }, 1636 1637 "Documentation": 1638 { 1639 "Description": "A hardware attention requiring service has occurred", 1640 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1641 "Message": "Error Signature: %1 %2 %3" 1642 } 1643 }, 1644 1645 { 1646 "Name": "org.open_power.HwDiags.Error.Informational", 1647 "PossibleSubsystems": [ 1648 "processor", "processor_fru", "processor_unit", "processor_bus", 1649 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1650 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1651 ], 1652 "Severity": "non_error", 1653 "ActionFlags": [ "hidden", "dont_report" ], 1654 1655 "SRC": 1656 { 1657 "ReasonCode": "0xE512", 1658 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1659 "Words6To9": 1660 { 1661 "6": 1662 { 1663 "AdditionalDataPropSource": "SRC6" 1664 }, 1665 "7": 1666 { 1667 "AdditionalDataPropSource": "SRC7" 1668 }, 1669 "8": 1670 { 1671 "AdditionalDataPropSource": "SRC8" 1672 } 1673 } 1674 }, 1675 1676 "Documentation": 1677 { 1678 "Description": "Manual analysis was initiated via the command line. FFDC only.", 1679 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1680 "Message": "Error Signature: %1 %2 %3" 1681 } 1682 }, 1683 1684 { 1685 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 1686 "Subsystem": "power_supply", 1687 "ActionFlags": ["service_action", "report"], 1688 "ComponentID": "0x2700", 1689 1690 "SRC": { 1691 "Type": "11", 1692 "ReasonCode": "0x15F0", 1693 "Words6To9": {} 1694 }, 1695 1696 "Callouts": [ 1697 { 1698 "CalloutList": [ 1699 { "Priority": "high", "SymbolicFRU": "pwrsply" } 1700 ] 1701 } 1702 ], 1703 1704 "Documentation": { 1705 "Description": "Power Supply input power fault", 1706 "Message": "A power supply has indicated an input or under voltage condition.", 1707 "Notes": [ 1708 "Check the power supply cabling and/or input power ", 1709 "source. The PWRSPLY procedure is used rather than ", 1710 "calling out a location code, as typically these faults ", 1711 "are related to the supplied power, the cable, or the ", 1712 "cable connectors. If the input fault resolves down to an ", 1713 "issue with the power supply itself, the power supply ", 1714 "indicating this input fault should be called out. Add the ", 1715 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 1716 "CALLOUT_PRIORITY to something other than high." 1717 ] 1718 } 1719 }, 1720 1721 { 1722 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 1723 "Subsystem": "power_supply", 1724 "ActionFlags": ["service_action", "report", "call_home"], 1725 "ComponentID": "0x2700", 1726 1727 "SRC": { 1728 "Type": "11", 1729 "ReasonCode": "0x15F1", 1730 "Words6To9": {} 1731 }, 1732 1733 "Callouts": [ 1734 { 1735 "CalloutList": [ 1736 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1737 ] 1738 } 1739 ], 1740 1741 "Documentation": { 1742 "Description": "Power Supply power fault", 1743 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 1744 "Notes": [ 1745 "The power supply reporting the fault should be called ", 1746 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1747 "specific fault, STATUS_* details, and code level in the ", 1748 "AdditionalData section." 1749 ] 1750 } 1751 }, 1752 1753 { 1754 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 1755 "Subsystem": "power_supply", 1756 "ActionFlags": ["service_action", "report", "call_home"], 1757 "ComponentID": "0x2700", 1758 1759 "SRC": { 1760 "Type": "11", 1761 "ReasonCode": "0x15F2", 1762 "Words6To9": {} 1763 }, 1764 1765 "Callouts": [ 1766 { 1767 "CalloutList": [ 1768 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1769 ] 1770 } 1771 ], 1772 1773 "Documentation": { 1774 "Description": "Power Supply non-power fault", 1775 "Message": "A communication failure occurred talking to the power supply", 1776 "Notes": [ 1777 "Communication problems with the power supply could be ", 1778 "the power supply, or any hardware between it and the ", 1779 "BMC. Reporting the error should be passing in a call ", 1780 "out using CALLOUT_DEVICE_PATH." 1781 ] 1782 } 1783 }, 1784 1785 { 1786 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 1787 "Subsystem": "power_supply", 1788 "ActionFlags": ["service_action", "report", "call_home"], 1789 "ComponentID": "0x2700", 1790 1791 "SRC": { 1792 "Type": "11", 1793 "ReasonCode": "0x15F6", 1794 "Words6To9": {} 1795 }, 1796 1797 "Callouts": [ 1798 { 1799 "CalloutList": [ 1800 { 1801 "Priority": "high", 1802 "SymbolicFRUTrusted": "pwrsply", 1803 "UseInventoryLocCode": true 1804 } 1805 ] 1806 } 1807 ], 1808 1809 "Documentation": { 1810 "Description": "Power Supply is missing", 1811 "Message": "A power supply that should be present is missing", 1812 "Notes": [ 1813 "The CalloutList should use the PWRSPLY symbolic FRU ", 1814 "with the trusted location code property. The ", 1815 "location code in this callout is obtained from ", 1816 "the passed in CALLOUT_INVENTORY_PATH value." 1817 ] 1818 } 1819 }, 1820 1821 { 1822 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 1823 "Subsystem": "power_supply", 1824 "ActionFlags": ["service_action", "report", "call_home"], 1825 "ComponentID": "0x2700", 1826 1827 "SRC": { 1828 "Type": "11", 1829 "ReasonCode": "0x15F7", 1830 "Words6To9": {} 1831 }, 1832 1833 "Callouts": [ 1834 { 1835 "CalloutList": [ 1836 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1837 ] 1838 } 1839 ], 1840 1841 "Documentation": { 1842 "Description": "Power Supply configuration is not supported", 1843 "Message": "The power supply configuration is not supported", 1844 "Notes": [ 1845 "The combination of power supplies detected in the ", 1846 "system is not supported. This could be caused by ", 1847 "mismatched models, less than expected number of power ", 1848 "supplies, or other unsupported characteristics." 1849 ] 1850 } 1851 }, 1852 1853 { 1854 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.FanFault", 1855 "Subsystem": "power_supply", 1856 "ActionFlags": ["service_action", "report", "call_home"], 1857 "ComponentID": "0x2700", 1858 1859 "SRC": { 1860 "Type": "11", 1861 "ReasonCode": "0x15FF", 1862 "Words6To9": {} 1863 }, 1864 1865 "Callouts": [ 1866 { 1867 "CalloutList": [ 1868 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1869 ] 1870 } 1871 ], 1872 1873 "Documentation": { 1874 "Description": "Power Supply fan fault", 1875 "Message": "A power supply indicated a fan fault has occurred", 1876 "Notes": [ 1877 "The power supply reporting the fault should be called ", 1878 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1879 "specific fault, STATUS_* details, and code level in the ", 1880 "AdditionalData section." 1881 ] 1882 } 1883 }, 1884 1885 { 1886 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 1887 "Subsystem": "power_supply", 1888 "ActionFlags": ["service_action", "report", "call_home"], 1889 "ComponentID": "0x2700", 1890 1891 "SRC": { 1892 "Type": "11", 1893 "ReasonCode": "0x1B01", 1894 "Words6To9": {} 1895 }, 1896 1897 "Callouts": [ 1898 { 1899 "CalloutList": [ 1900 { "Priority": "high", "Procedure": "power_overcurrent" } 1901 ] 1902 } 1903 ], 1904 1905 "Documentation": { 1906 "Description": "Power Supply output over-current power fault", 1907 "Message": "A power supply has indicated an output over-current condition." 1908 } 1909 }, 1910 1911 { 1912 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1913 "Subsystem": "power", 1914 "ActionFlags": [ "report", "service_action" ], 1915 "ComponentID": "0x2700", 1916 1917 "SRC": 1918 { 1919 "Type": "11", 1920 "ReasonCode": "0x00AC", 1921 "Words6To9": {} 1922 }, 1923 1924 "Callouts": [ 1925 { 1926 "CalloutList": [ 1927 { "Priority": "high", "SymbolicFRU": "ac_module"} 1928 ] 1929 } 1930 ], 1931 1932 "Documentation": { 1933 "Description": "Input power was lost while the system was powered on.", 1934 "Message": "Input power was lost while the system was powered on.", 1935 "Notes": [ 1936 "Input power was lost while system powered on.", 1937 "The CalloutList should use the ACMODUL symbolic FRU." 1938 ] 1939 } 1940 }, 1941 1942 { 1943 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1944 "Subsystem": "power_supply", 1945 "ActionFlags": ["service_action", "report", "call_home"], 1946 "ComponentID": "0x2700", 1947 1948 "SRC": { 1949 "Type": "11", 1950 "ReasonCode": "0x2500", 1951 "Words6To9": {} 1952 }, 1953 1954 "Callouts": [ 1955 { 1956 "CalloutList": [ 1957 { "Priority": "high", "Procedure": "power_overcurrent" } 1958 ] 1959 } 1960 ], 1961 1962 "Documentation": { 1963 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1964 "Message": "Power supply PSKill_fault", 1965 "Notes": [ 1966 ] 1967 } 1968 }, 1969 1970 { 1971 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1972 "Subsystem": "power_sequencer", 1973 "ComponentID": "0x2700", 1974 1975 "SRC": { 1976 "Type": "11", 1977 "ReasonCode": "0x2600", 1978 "Words6To9": {} 1979 }, 1980 1981 "Callouts": [ 1982 { 1983 "CalloutList": [ 1984 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1985 ] 1986 } 1987 ], 1988 1989 "Documentation": { 1990 "Description": "A power off was issued because a power fault was detected", 1991 "Message": "A power off was issued because a power fault was detected", 1992 "Notes": [ 1993 ] 1994 } 1995 }, 1996 1997 { 1998 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1999 "Subsystem": "power_control_hw", 2000 "Severity": "critical_system_term", 2001 "ComponentID": "0x2700", 2002 2003 "SRC": { 2004 "Type": "11", 2005 "ReasonCode": "0x2602", 2006 "Words6To9": {} 2007 }, 2008 2009 "Callouts": [ 2010 { 2011 "System": "ibm,rainier", 2012 "CalloutList": [ 2013 { 2014 "Priority": "high", 2015 "LocCode": "P0-C5" 2016 }, 2017 { 2018 "Priority": "medium", 2019 "LocCode": "P0" 2020 } 2021 ] 2022 }, 2023 { 2024 "System": "ibm,everest", 2025 "CalloutList": [ 2026 { 2027 "Priority": "high", 2028 "LocCode": "P0-C59" 2029 }, 2030 { 2031 "Priority": "medium", 2032 "LocCode": "P0" 2033 } 2034 ] 2035 } 2036 ], 2037 2038 "Documentation": { 2039 "Description": "A power off was issued because a regulator for standby power faulted", 2040 "Message": "A power off was issued because a regulator for standby power faulted", 2041 "Notes": [ 2042 ] 2043 } 2044 }, 2045 2046 { 2047 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 2048 "Subsystem": "power_sequencer", 2049 "ComponentID": "0x2700", 2050 2051 "SRC": { 2052 "Type": "11", 2053 "ReasonCode": "0x2610", 2054 "Words6To9": {} 2055 }, 2056 2057 "CalloutsUsingAD": { 2058 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 2059 { 2060 "ADValue": "PCIE_SLOT0", "Callouts": [ 2061 { 2062 "CalloutList": [ 2063 { "Priority": "high", "LocCode": "P0-C0" }, 2064 { "Priority": "medium", "LocCode": "P0" } 2065 ] 2066 } 2067 ] 2068 }, 2069 { 2070 "ADValue": "PCIE_SLOT1", "Callouts": [ 2071 { 2072 "CalloutList": [ 2073 { "Priority": "high", "LocCode": "P0-C1" }, 2074 { "Priority": "medium", "LocCode": "P0" } 2075 ] 2076 } 2077 ] 2078 }, 2079 { 2080 "ADValue": "PCIE_SLOT2", "Callouts": [ 2081 { 2082 "CalloutList": [ 2083 { "Priority": "high", "LocCode": "P0-C2" }, 2084 { "Priority": "medium", "LocCode": "P0" } 2085 ] 2086 } 2087 ] 2088 }, 2089 { 2090 "ADValue": "PCIE_SLOT3", "Callouts": [ 2091 { 2092 "CalloutList": [ 2093 { "Priority": "high", "LocCode": "P0-C3" }, 2094 { "Priority": "medium", "LocCode": "P0" } 2095 ] 2096 } 2097 ] 2098 }, 2099 { 2100 "ADValue": "PCIE_SLOT4", "Callouts": [ 2101 { 2102 "CalloutList": [ 2103 { "Priority": "high", "LocCode": "P0-C4" }, 2104 { "Priority": "medium", "LocCode": "P0" } 2105 ] 2106 } 2107 ] 2108 }, 2109 { 2110 "ADValue": "PCIE_SLOT5", "Callouts": [ 2111 { 2112 "CalloutList": [ 2113 { "Priority": "high", "LocCode": "P0-C5" }, 2114 { "Priority": "medium", "LocCode": "P0" } 2115 ] 2116 } 2117 ] 2118 }, 2119 { 2120 "ADValue": "PCIE_SLOT6", "Callouts": [ 2121 { 2122 "CalloutList": [ 2123 { "Priority": "high", "LocCode": "P0-C6" }, 2124 { "Priority": "medium", "LocCode": "P0" } 2125 ] 2126 } 2127 ] 2128 }, 2129 { 2130 "ADValue": "PCIE_SLOT7", "Callouts": [ 2131 { 2132 "CalloutList": [ 2133 { "Priority": "high", "LocCode": "P0-C7" }, 2134 { "Priority": "medium", "LocCode": "P0" } 2135 ] 2136 } 2137 ] 2138 }, 2139 { 2140 "ADValue": "PCIE_SLOT8", "Callouts": [ 2141 { 2142 "CalloutList": [ 2143 { "Priority": "high", "LocCode": "P0-C8" }, 2144 { "Priority": "medium", "LocCode": "P0" } 2145 ] 2146 } 2147 ] 2148 }, 2149 { 2150 "ADValue": "PCIE_SLOT9", "Callouts": [ 2151 { 2152 "CalloutList": [ 2153 { "Priority": "high", "LocCode": "P0-C9" }, 2154 { "Priority": "medium", "LocCode": "P0" } 2155 ] 2156 } 2157 ] 2158 }, 2159 { 2160 "ADValue": "PCIE_SLOT10", "Callouts": [ 2161 { 2162 "CalloutList": [ 2163 { "Priority": "high", "LocCode": "P0-C10" }, 2164 { "Priority": "medium", "LocCode": "P0" } 2165 ] 2166 } 2167 ] 2168 }, 2169 { 2170 "ADValue": "PCIE_SLOT11", "Callouts": [ 2171 { 2172 "CalloutList": [ 2173 { "Priority": "high", "LocCode": "P0-C11" }, 2174 { "Priority": "medium", "LocCode": "P0" } 2175 ] 2176 } 2177 ] 2178 }, 2179 { 2180 "ADValue": "PGOOD_12A", "Callouts": [ 2181 { 2182 "CalloutList": [ 2183 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2184 ] 2185 } 2186 ] 2187 }, 2188 { 2189 "ADValue": "PGOOD_12B", "Callouts": [ 2190 { 2191 "CalloutList": [ 2192 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2193 ] 2194 } 2195 ] 2196 }, 2197 { 2198 "ADValue": "PGOOD_12C", "Callouts": [ 2199 { 2200 "CalloutList": [ 2201 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2202 ] 2203 } 2204 ] 2205 }, 2206 { 2207 "ADValue": "PGOOD_12D", "Callouts": [ 2208 { 2209 "CalloutList": [ 2210 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2211 ] 2212 } 2213 ] 2214 }, 2215 { 2216 "ADValue": "PGOOD_12L", "Callouts": [ 2217 { 2218 "CalloutList": [ 2219 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2220 ] 2221 } 2222 ] 2223 }, 2224 { 2225 "ADValue": "PGOOD_12M", "Callouts": [ 2226 { 2227 "CalloutList": [ 2228 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2229 ] 2230 } 2231 ] 2232 }, 2233 { 2234 "ADValue": "PGOOD_12N", "Callouts": [ 2235 { 2236 "CalloutList": [ 2237 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2238 ] 2239 } 2240 ] 2241 }, 2242 { 2243 "ADValue": "PGOOD_12P", "Callouts": [ 2244 { 2245 "CalloutList": [ 2246 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2247 ] 2248 } 2249 ] 2250 }, 2251 { 2252 "ADValue": "PGOOD_12PCIE", "Callouts": [ 2253 { 2254 "CalloutList": [ 2255 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2256 ] 2257 } 2258 ] 2259 }, 2260 { 2261 "ADValue": "PGOOD_12Q", "Callouts": [ 2262 { 2263 "CalloutList": [ 2264 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2265 ] 2266 } 2267 ] 2268 }, 2269 { 2270 "ADValue": "PGOOD_12R", "Callouts": [ 2271 { 2272 "CalloutList": [ 2273 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2274 ] 2275 } 2276 ] 2277 }, 2278 { 2279 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 2280 { 2281 "CalloutList": [ 2282 { "Priority": "high", "LocCode": "P0-C14" }, 2283 { "Priority": "medium", "LocCode": "P0-C15" }, 2284 { "Priority": "low", "LocCode": "P0" } 2285 ] 2286 } 2287 ] 2288 }, 2289 { 2290 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 2291 { 2292 "CalloutList": [ 2293 { "Priority": "high", "LocCode": "P0-C23" }, 2294 { "Priority": "medium", "LocCode": "P0-C24" }, 2295 { "Priority": "low", "LocCode": "P0" } 2296 ] 2297 } 2298 ] 2299 }, 2300 { 2301 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 2302 { 2303 "CalloutList": [ 2304 { "Priority": "high", "LocCode": "P0-C14" }, 2305 { "Priority": "medium", "LocCode": "P0-C15" }, 2306 { "Priority": "low", "LocCode": "P0" } 2307 ] 2308 } 2309 ] 2310 }, 2311 { 2312 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 2313 { 2314 "CalloutList": [ 2315 { "Priority": "high", "LocCode": "P0-C23" }, 2316 { "Priority": "medium", "LocCode": "P0-C24" }, 2317 { "Priority": "low", "LocCode": "P0" } 2318 ] 2319 } 2320 ] 2321 }, 2322 { 2323 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 2324 { 2325 "CalloutList": [ 2326 { "Priority": "high", "LocCode": "P0-C14" }, 2327 { "Priority": "medium", "LocCode": "P0-C15" }, 2328 { "Priority": "low", "LocCode": "P0" } 2329 ] 2330 } 2331 ] 2332 }, 2333 { 2334 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 2335 { 2336 "CalloutList": [ 2337 { "Priority": "high", "LocCode": "P0-C23" }, 2338 { "Priority": "medium", "LocCode": "P0-C24" }, 2339 { "Priority": "low", "LocCode": "P0" } 2340 ] 2341 } 2342 ] 2343 }, 2344 { 2345 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 2346 { 2347 "CalloutList": [ 2348 { "Priority": "high", "LocCode": "P0-C14" }, 2349 { "Priority": "medium", "LocCode": "P0-C15" }, 2350 { "Priority": "low", "LocCode": "P0" } 2351 ] 2352 } 2353 ] 2354 }, 2355 { 2356 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 2357 { 2358 "CalloutList": [ 2359 { "Priority": "high", "LocCode": "P0-C23" }, 2360 { "Priority": "medium", "LocCode": "P0-C24" }, 2361 { "Priority": "low", "LocCode": "P0" } 2362 ] 2363 } 2364 ] 2365 }, 2366 { 2367 "ADValue": "CP0_VPCIE", "Callouts": [ 2368 { 2369 "CalloutList": [ 2370 { "Priority": "high", "LocCode": "P0-C58" }, 2371 { "Priority": "medium", "LocCode": "P0-C61" }, 2372 { "Priority": "low", "LocCode": "P0" } 2373 ] 2374 } 2375 ] 2376 }, 2377 { 2378 "ADValue": "CP1_VPCIE", "Callouts": [ 2379 { 2380 "CalloutList": [ 2381 { "Priority": "high", "LocCode": "P0-C16" }, 2382 { "Priority": "medium", "LocCode": "P0-C14" }, 2383 { "Priority": "low", "LocCode": "P0" } 2384 ] 2385 } 2386 ] 2387 }, 2388 { 2389 "ADValue": "CP2_VPCIE", "Callouts": [ 2390 { 2391 "CalloutList": [ 2392 { "Priority": "high", "LocCode": "P0-C16" }, 2393 { "Priority": "medium", "LocCode": "P0-C19" }, 2394 { "Priority": "low", "LocCode": "P0" } 2395 ] 2396 } 2397 ] 2398 }, 2399 { 2400 "ADValue": "CP3_VPCIE", "Callouts": [ 2401 { 2402 "CalloutList": [ 2403 { "Priority": "high", "LocCode": "P0-C58" }, 2404 { "Priority": "medium", "LocCode": "P0-C56" }, 2405 { "Priority": "low", "LocCode": "P0" } 2406 ] 2407 } 2408 ] 2409 }, 2410 { 2411 "ADValue": "5.0V_USB_front", "Callouts": [ 2412 { 2413 "CalloutList": [ 2414 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2415 { "Priority": "low", "LocCode": "P1" }, 2416 { "Priority": "low", "LocCode": "P0" } 2417 ] 2418 } 2419 ] 2420 }, 2421 { 2422 "ADValue": "CP0_VDN", "Callouts": [ 2423 { 2424 "CalloutList": [ 2425 { "Priority": "high", "LocCode": "P0-C63" }, 2426 { "Priority": "medium", "LocCode": "P0-C61" }, 2427 { "Priority": "low", "LocCode": "P0" } 2428 ] 2429 } 2430 ] 2431 }, 2432 { 2433 "ADValue": "CP1_VDN", "Callouts": [ 2434 { 2435 "CalloutList": [ 2436 { "Priority": "high", "LocCode": "P0-C12" }, 2437 { "Priority": "medium", "LocCode": "P0-C14" }, 2438 { "Priority": "low", "LocCode": "P0" } 2439 ] 2440 } 2441 ] 2442 }, 2443 { 2444 "ADValue": "CP2_VDN", "Callouts": [ 2445 { 2446 "CalloutList": [ 2447 { "Priority": "high", "LocCode": "P0-C21" }, 2448 { "Priority": "medium", "LocCode": "P0-C19" }, 2449 { "Priority": "low", "LocCode": "P0" } 2450 ] 2451 } 2452 ] 2453 }, 2454 { 2455 "ADValue": "CP3_VDN", "Callouts": [ 2456 { 2457 "CalloutList": [ 2458 { "Priority": "high", "LocCode": "P0-C54" }, 2459 { "Priority": "medium", "LocCode": "P0-C56" }, 2460 { "Priority": "low", "LocCode": "P0" } 2461 ] 2462 } 2463 ] 2464 }, 2465 { 2466 "ADValue": "CP0_VIO", "Callouts": [ 2467 { 2468 "CalloutList": [ 2469 { "Priority": "high", "LocCode": "P0-C63" }, 2470 { "Priority": "medium", "LocCode": "P0-C61" }, 2471 { "Priority": "low", "LocCode": "P0" } 2472 ] 2473 } 2474 ] 2475 }, 2476 { 2477 "ADValue": "CP1_VIO", "Callouts": [ 2478 { 2479 "CalloutList": [ 2480 { "Priority": "high", "LocCode": "P0-C12" }, 2481 { "Priority": "medium", "LocCode": "P0-C14" }, 2482 { "Priority": "low", "LocCode": "P0" } 2483 ] 2484 } 2485 ] 2486 }, 2487 { 2488 "ADValue": "CP2_VIO", "Callouts": [ 2489 { 2490 "CalloutList": [ 2491 { "Priority": "high", "LocCode": "P0-C21" }, 2492 { "Priority": "medium", "LocCode": "P0-C19" }, 2493 { "Priority": "low", "LocCode": "P0" } 2494 ] 2495 } 2496 ] 2497 }, 2498 { 2499 "ADValue": "CP3_VIO", "Callouts": [ 2500 { 2501 "CalloutList": [ 2502 { "Priority": "high", "LocCode": "P0-C54" }, 2503 { "Priority": "medium", "LocCode": "P0-C56" }, 2504 { "Priority": "low", "LocCode": "P0" } 2505 ] 2506 } 2507 ] 2508 }, 2509 { 2510 "ADValue": "PGOOD_PSU1", "Callouts": [ 2511 { 2512 "CalloutList": [ 2513 { "Priority": "high", "LocCode": "E0" } 2514 ] 2515 } 2516 ] 2517 }, 2518 { 2519 "ADValue": "PGOOD_PSU2", "Callouts": [ 2520 { 2521 "CalloutList": [ 2522 { "Priority": "high", "LocCode": "E1" } 2523 ] 2524 } 2525 ] 2526 }, 2527 { 2528 "ADValue": "PGOOD_PSU3", "Callouts": [ 2529 { 2530 "CalloutList": [ 2531 { "Priority": "high", "LocCode": "E2" } 2532 ] 2533 } 2534 ] 2535 }, 2536 { 2537 "ADValue": "PGOOD_PSU4", "Callouts": [ 2538 { 2539 "CalloutList": [ 2540 { "Priority": "high", "LocCode": "E3" } 2541 ] 2542 } 2543 ] 2544 } 2545 ] 2546 }, 2547 2548 "Documentation": { 2549 "Description": "The power sequencer chip detected a PGOOD fault", 2550 "Message": "The power sequencer chip detected a PGOOD fault", 2551 "Notes": [ 2552 ] 2553 } 2554 }, 2555 2556 { 2557 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 2558 "Subsystem": "power_sequencer", 2559 "ComponentID": "0x2700", 2560 2561 "SRC": { 2562 "Type": "11", 2563 "ReasonCode": "0x2620", 2564 "Words6To9": {} 2565 }, 2566 2567 "CalloutsUsingAD": { 2568 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 2569 { 2570 "ADValue": "12.0V", "Callouts": [ 2571 { 2572 "CalloutList": [ 2573 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2574 ] 2575 } 2576 ] 2577 }, 2578 { 2579 "ADValue": "5.0V_USB", "Callouts": [ 2580 { 2581 "CalloutList": [ 2582 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2583 { "Priority": "medium", "LocCode": "P0" } 2584 ] 2585 } 2586 ] 2587 }, 2588 { 2589 "ADValue": "5.0V_DASD", "Callouts": [ 2590 { 2591 "CalloutList": [ 2592 { "Priority": "medium", "LocCode": "P1" }, 2593 { "Priority": "medium", "LocCode": "P2" }, 2594 { "Priority": "low", "LocCode": "P0" } 2595 ] 2596 } 2597 ] 2598 }, 2599 { 2600 "ADValue": "3.3VA", "Callouts": [ 2601 { 2602 "CalloutList": [ 2603 { "Priority": "high", "LocCode": "P0" } 2604 ] 2605 } 2606 ] 2607 }, 2608 { 2609 "ADValue": "3.3VB", "Callouts": [ 2610 { 2611 "CalloutList": [ 2612 { "Priority": "high", "LocCode": "P0" } 2613 ] 2614 } 2615 ] 2616 }, 2617 { 2618 "ADValue": "3V3IO", "Callouts": [ 2619 { 2620 "CalloutList": [ 2621 { "Priority": "high", "LocCode": "P0-C17" }, 2622 { "Priority": "medium", "LocCode": "P0-C96" }, 2623 { "Priority": "medium", "LocCode": "P0-C0" }, 2624 { "Priority": "medium", "SymbolicFRU": "pcie_hot_plug" }, 2625 { "Priority": "low", "LocCode": "P0" } 2626 ] 2627 } 2628 ] 2629 }, 2630 { 2631 "ADValue": "1.5V", "Callouts": [ 2632 { 2633 "CalloutList": [ 2634 { "Priority": "high", "LocCode": "P0" } 2635 ] 2636 } 2637 ] 2638 }, 2639 { 2640 "ADValue": "1.1V", "Callouts": [ 2641 { 2642 "CalloutList": [ 2643 { "Priority": "high", "LocCode": "P0" } 2644 ] 2645 } 2646 ] 2647 }, 2648 { 2649 "ADValue": "VDDA_DCM0", "Callouts": [ 2650 { 2651 "CalloutList": [ 2652 { "Priority": "high", "LocCode": "P0-C14" }, 2653 { "Priority": "medium", "LocCode": "P0-C15" }, 2654 { "Priority": "low", "LocCode": "P0" } 2655 ] 2656 } 2657 ] 2658 }, 2659 { 2660 "ADValue": "VDDB_DCM0", "Callouts": [ 2661 { 2662 "CalloutList": [ 2663 { "Priority": "high", "LocCode": "P0-C14" }, 2664 { "Priority": "medium", "LocCode": "P0-C15" }, 2665 { "Priority": "low", "LocCode": "P0" } 2666 ] 2667 } 2668 ] 2669 }, 2670 { 2671 "ADValue": "VDDA_DCM1", "Callouts": [ 2672 { 2673 "CalloutList": [ 2674 { "Priority": "high", "LocCode": "P0-C23" }, 2675 { "Priority": "medium", "LocCode": "P0-C24" }, 2676 { "Priority": "low", "LocCode": "P0" } 2677 ] 2678 } 2679 ] 2680 }, 2681 { 2682 "ADValue": "VDDB_DCM1", "Callouts": [ 2683 { 2684 "CalloutList": [ 2685 { "Priority": "high", "LocCode": "P0-C23" }, 2686 { "Priority": "medium", "LocCode": "P0-C24" }, 2687 { "Priority": "low", "LocCode": "P0" } 2688 ] 2689 } 2690 ] 2691 }, 2692 { 2693 "ADValue": "CP03_AVDD", "Callouts": [ 2694 { 2695 "CalloutList": [ 2696 { "Priority": "high", "LocCode": "P0-C58" }, 2697 { "Priority": "medium", "LocCode": "P0-C61" }, 2698 { "Priority": "medium", "LocCode": "P0-C56" }, 2699 { "Priority": "low", "LocCode": "P0" } 2700 ] 2701 } 2702 ] 2703 }, 2704 { 2705 "ADValue": "CP12_AVDD", "Callouts": [ 2706 { 2707 "CalloutList": [ 2708 { "Priority": "high", "LocCode": "P0-C16" }, 2709 { "Priority": "medium", "LocCode": "P0-C14" }, 2710 { "Priority": "medium", "LocCode": "P0-C19" }, 2711 { "Priority": "low", "LocCode": "P0" } 2712 ] 2713 } 2714 ] 2715 }, 2716 { 2717 "ADValue": "CP0_VDD0", "Callouts": [ 2718 { 2719 "CalloutList": [ 2720 { "Priority": "high", "LocCode": "P0-C62" }, 2721 { "Priority": "medium", "LocCode": "P0-C61" }, 2722 { "Priority": "low", "LocCode": "P0" } 2723 ] 2724 } 2725 ] 2726 }, 2727 { 2728 "ADValue": "CP0_VDD1", "Callouts": [ 2729 { 2730 "CalloutList": [ 2731 { "Priority": "high", "LocCode": "P0-C60" }, 2732 { "Priority": "medium", "LocCode": "P0-C61" }, 2733 { "Priority": "low", "LocCode": "P0" } 2734 ] 2735 } 2736 ] 2737 }, 2738 { 2739 "ADValue": "CP1_VDD0", "Callouts": [ 2740 { 2741 "CalloutList": [ 2742 { "Priority": "high", "LocCode": "P0-C13" }, 2743 { "Priority": "medium", "LocCode": "P0-C14" }, 2744 { "Priority": "low", "LocCode": "P0" } 2745 ] 2746 } 2747 ] 2748 }, 2749 { 2750 "ADValue": "CP1_VDD1", "Callouts": [ 2751 { 2752 "CalloutList": [ 2753 { "Priority": "high", "LocCode": "P0-C15" }, 2754 { "Priority": "medium", "LocCode": "P0-C14" }, 2755 { "Priority": "low", "LocCode": "P0" } 2756 ] 2757 } 2758 ] 2759 }, 2760 { 2761 "ADValue": "CP2_VDD0", "Callouts": [ 2762 { 2763 "CalloutList": [ 2764 { "Priority": "high", "LocCode": "P0-C18" }, 2765 { "Priority": "medium", "LocCode": "P0-C19" }, 2766 { "Priority": "low", "LocCode": "P0" } 2767 ] 2768 } 2769 ] 2770 }, 2771 { 2772 "ADValue": "CP2_VDD1", "Callouts": [ 2773 { 2774 "CalloutList": [ 2775 { "Priority": "high", "LocCode": "P0-C20" }, 2776 { "Priority": "medium", "LocCode": "P0-C19" }, 2777 { "Priority": "low", "LocCode": "P0" } 2778 ] 2779 } 2780 ] 2781 }, 2782 { 2783 "ADValue": "CP3_VDD0", "Callouts": [ 2784 { 2785 "CalloutList": [ 2786 { "Priority": "high", "LocCode": "P0-C57" }, 2787 { "Priority": "medium", "LocCode": "P0-C56" }, 2788 { "Priority": "low", "LocCode": "P0" } 2789 ] 2790 } 2791 ] 2792 }, 2793 { 2794 "ADValue": "CP3_VDD1", "Callouts": [ 2795 { 2796 "CalloutList": [ 2797 { "Priority": "high", "LocCode": "P0-C55" }, 2798 { "Priority": "medium", "LocCode": "P0-C56" }, 2799 { "Priority": "low", "LocCode": "P0" } 2800 ] 2801 } 2802 ] 2803 }, 2804 { 2805 "ADValue": "CP0_VCS0", "Callouts": [ 2806 { 2807 "CalloutList": [ 2808 { "Priority": "high", "LocCode": "P0-C63" }, 2809 { "Priority": "medium", "LocCode": "P0-C61" }, 2810 { "Priority": "low", "LocCode": "P0" } 2811 ] 2812 } 2813 ] 2814 }, 2815 { 2816 "ADValue": "CP0_VCS1", "Callouts": [ 2817 { 2818 "CalloutList": [ 2819 { "Priority": "high", "LocCode": "P0-C59" }, 2820 { "Priority": "medium", "LocCode": "P0-C61" }, 2821 { "Priority": "low", "LocCode": "P0" } 2822 ] 2823 } 2824 ] 2825 }, 2826 { 2827 "ADValue": "CP1_VCS0", "Callouts": [ 2828 { 2829 "CalloutList": [ 2830 { "Priority": "high", "LocCode": "P0-C12" }, 2831 { "Priority": "medium", "LocCode": "P0-C14" }, 2832 { "Priority": "low", "LocCode": "P0" } 2833 ] 2834 } 2835 ] 2836 }, 2837 { 2838 "ADValue": "CP1_VCS1", "Callouts": [ 2839 { 2840 "CalloutList": [ 2841 { "Priority": "high", "LocCode": "P0-C16" }, 2842 { "Priority": "medium", "LocCode": "P0-C14" }, 2843 { "Priority": "low", "LocCode": "P0" } 2844 ] 2845 } 2846 ] 2847 }, 2848 { 2849 "ADValue": "CP2_VCS0", "Callouts": [ 2850 { 2851 "CalloutList": [ 2852 { "Priority": "high", "LocCode": "P0-C17" }, 2853 { "Priority": "medium", "LocCode": "P0-C19" }, 2854 { "Priority": "low", "LocCode": "P0" } 2855 ] 2856 } 2857 ] 2858 }, 2859 { 2860 "ADValue": "CP2_VCS1", "Callouts": [ 2861 { 2862 "CalloutList": [ 2863 { "Priority": "high", "LocCode": "P0-C21" }, 2864 { "Priority": "medium", "LocCode": "P0-C19" }, 2865 { "Priority": "low", "LocCode": "P0" } 2866 ] 2867 } 2868 ] 2869 }, 2870 { 2871 "ADValue": "CP3_VCS0", "Callouts": [ 2872 { 2873 "CalloutList": [ 2874 { "Priority": "high", "LocCode": "P0-C58" }, 2875 { "Priority": "medium", "LocCode": "P0-C56" }, 2876 { "Priority": "low", "LocCode": "P0" } 2877 ] 2878 } 2879 ] 2880 }, 2881 { 2882 "ADValue": "CP3_VCS1", "Callouts": [ 2883 { 2884 "CalloutList": [ 2885 { "Priority": "high", "LocCode": "P0-C54" }, 2886 { "Priority": "medium", "LocCode": "P0-C56" }, 2887 { "Priority": "low", "LocCode": "P0" } 2888 ] 2889 } 2890 ] 2891 }, 2892 { 2893 "ADValue": "CP0_VDN", "Callouts": [ 2894 { 2895 "CalloutList": [ 2896 { "Priority": "high", "LocCode": "P0-C63" }, 2897 { "Priority": "medium", "LocCode": "P0-C61" }, 2898 { "Priority": "low", "LocCode": "P0" } 2899 ] 2900 } 2901 ] 2902 }, 2903 { 2904 "ADValue": "CP1_VDN", "Callouts": [ 2905 { 2906 "CalloutList": [ 2907 { "Priority": "high", "LocCode": "P0-C12" }, 2908 { "Priority": "medium", "LocCode": "P0-C14" }, 2909 { "Priority": "low", "LocCode": "P0" } 2910 ] 2911 } 2912 ] 2913 }, 2914 { 2915 "ADValue": "CP2_VDN", "Callouts": [ 2916 { 2917 "CalloutList": [ 2918 { "Priority": "high", "LocCode": "P0-C21" }, 2919 { "Priority": "medium", "LocCode": "P0-C19" }, 2920 { "Priority": "low", "LocCode": "P0" } 2921 ] 2922 } 2923 ] 2924 }, 2925 { 2926 "ADValue": "CP3_VDN", "Callouts": [ 2927 { 2928 "CalloutList": [ 2929 { "Priority": "high", "LocCode": "P0-C54" }, 2930 { "Priority": "medium", "LocCode": "P0-C56" }, 2931 { "Priority": "low", "LocCode": "P0" } 2932 ] 2933 } 2934 ] 2935 }, 2936 { 2937 "ADValue": "CP0_VIO", "Callouts": [ 2938 { 2939 "CalloutList": [ 2940 { "Priority": "high", "LocCode": "P0-C63" }, 2941 { "Priority": "medium", "LocCode": "P0-C61" }, 2942 { "Priority": "low", "LocCode": "P0" } 2943 ] 2944 } 2945 ] 2946 }, 2947 { 2948 "ADValue": "CP1_VIO", "Callouts": [ 2949 { 2950 "CalloutList": [ 2951 { "Priority": "high", "LocCode": "P0-C12" }, 2952 { "Priority": "medium", "LocCode": "P0-C14" }, 2953 { "Priority": "low", "LocCode": "P0" } 2954 ] 2955 } 2956 ] 2957 }, 2958 { 2959 "ADValue": "CP2_VIO", "Callouts": [ 2960 { 2961 "CalloutList": [ 2962 { "Priority": "high", "LocCode": "P0-C21" }, 2963 { "Priority": "medium", "LocCode": "P0-C19" }, 2964 { "Priority": "low", "LocCode": "P0" } 2965 ] 2966 } 2967 ] 2968 }, 2969 { 2970 "ADValue": "CP3_VIO", "Callouts": [ 2971 { 2972 "CalloutList": [ 2973 { "Priority": "high", "LocCode": "P0-C54" }, 2974 { "Priority": "medium", "LocCode": "P0-C56" }, 2975 { "Priority": "low", "LocCode": "P0" } 2976 ] 2977 } 2978 ] 2979 }, 2980 { 2981 "ADValue": "CP0_VPCIE", "Callouts": [ 2982 { 2983 "CalloutList": [ 2984 { "Priority": "high", "LocCode": "P0-C58" }, 2985 { "Priority": "medium", "LocCode": "P0-C61" }, 2986 { "Priority": "low", "LocCode": "P0" } 2987 ] 2988 } 2989 ] 2990 }, 2991 { 2992 "ADValue": "CP1_VPCIE", "Callouts": [ 2993 { 2994 "CalloutList": [ 2995 { "Priority": "high", "LocCode": "P0-C16" }, 2996 { "Priority": "medium", "LocCode": "P0-C14" }, 2997 { "Priority": "low", "LocCode": "P0" } 2998 ] 2999 } 3000 ] 3001 }, 3002 { 3003 "ADValue": "CP2_VPCIE", "Callouts": [ 3004 { 3005 "CalloutList": [ 3006 { "Priority": "high", "LocCode": "P0-C16" }, 3007 { "Priority": "medium", "LocCode": "P0-C19" }, 3008 { "Priority": "low", "LocCode": "P0" } 3009 ] 3010 } 3011 ] 3012 }, 3013 { 3014 "ADValue": "CP3_VPCIE", "Callouts": [ 3015 { 3016 "CalloutList": [ 3017 { "Priority": "high", "LocCode": "P0-C58" }, 3018 { "Priority": "medium", "LocCode": "P0-C56" }, 3019 { "Priority": "low", "LocCode": "P0" } 3020 ] 3021 } 3022 ] 3023 }, 3024 { 3025 "ADValue": "12.0VCS", "Callouts": [ 3026 { 3027 "CalloutList": [ 3028 { "Priority": "high", "SymbolicFRU": "pgood_part" } 3029 ] 3030 } 3031 ] 3032 }, 3033 { 3034 "ADValue": "3.3VCS", "Callouts": [ 3035 { 3036 "CalloutList": [ 3037 { "Priority": "high", "LocCode": "P0" } 3038 ] 3039 } 3040 ] 3041 }, 3042 { 3043 "ADValue": "1.1V_Current", "Callouts": [ 3044 { 3045 "CalloutList": [ 3046 { "Priority": "high", "LocCode": "P0" } 3047 ] 3048 } 3049 ] 3050 }, 3051 { 3052 "ADValue": "5.0V_USB_Current", "Callouts": [ 3053 { 3054 "CalloutList": [ 3055 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 3056 { "Priority": "medium", "LocCode": "P0" } 3057 ] 3058 } 3059 ] 3060 }, 3061 { 3062 "ADValue": "5.0V_DASD_Current", "Callouts": [ 3063 { 3064 "CalloutList": [ 3065 { "Priority": "medium", "LocCode": "P1" }, 3066 { "Priority": "medium", "LocCode": "P2" }, 3067 { "Priority": "low", "LocCode": "P0" } 3068 ] 3069 } 3070 ] 3071 }, 3072 { 3073 "ADValue": "12.0VN", "Callouts": [ 3074 { 3075 "CalloutList": [ 3076 { "Priority": "high", "SymbolicFRU": "pgood_part" } 3077 ] 3078 } 3079 ] 3080 }, 3081 { 3082 "ADValue": "12.0VP", "Callouts": [ 3083 { 3084 "CalloutList": [ 3085 { "Priority": "high", "SymbolicFRU": "pgood_part" } 3086 ] 3087 } 3088 ] 3089 }, 3090 { 3091 "ADValue": "12.0VQ", "Callouts": [ 3092 { 3093 "CalloutList": [ 3094 { "Priority": "high", "SymbolicFRU": "pgood_part" } 3095 ] 3096 } 3097 ] 3098 }, 3099 { 3100 "ADValue": "12.0VR", "Callouts": [ 3101 { 3102 "CalloutList": [ 3103 { "Priority": "high", "SymbolicFRU": "pgood_part" } 3104 ] 3105 } 3106 ] 3107 }, 3108 { 3109 "ADValue": "ThermalDiode1", "Callouts": [ 3110 { 3111 "CalloutList": [ 3112 { "Priority": "high", "LocCode": "P0" } 3113 ] 3114 } 3115 ] 3116 }, 3117 { 3118 "ADValue": "ThermalDiode2", "Callouts": [ 3119 { 3120 "CalloutList": [ 3121 { "Priority": "high", "LocCode": "P0" } 3122 ] 3123 } 3124 ] 3125 }, 3126 { 3127 "ADValue": "ThermalDiode3", "Callouts": [ 3128 { 3129 "CalloutList": [ 3130 { "Priority": "high", "LocCode": "P0" } 3131 ] 3132 } 3133 ] 3134 }, 3135 { 3136 "ADValue": "ThermalDiode4", "Callouts": [ 3137 { 3138 "CalloutList": [ 3139 { "Priority": "high", "LocCode": "P0" } 3140 ] 3141 } 3142 ] 3143 }, 3144 { 3145 "ADValue": "VDN_DCM0", "Callouts": [ 3146 { 3147 "CalloutList": [ 3148 { "Priority": "high", "LocCode": "P0-C14" }, 3149 { "Priority": "medium", "LocCode": "P0-C15" }, 3150 { "Priority": "low", "LocCode": "P0" } 3151 ] 3152 } 3153 ] 3154 }, 3155 { 3156 "ADValue": "VDN_DCM1", "Callouts": [ 3157 { 3158 "CalloutList": [ 3159 { "Priority": "high", "LocCode": "P0-C23" }, 3160 { "Priority": "medium", "LocCode": "P0-C24" }, 3161 { "Priority": "low", "LocCode": "P0" } 3162 ] 3163 } 3164 ] 3165 }, 3166 { 3167 "ADValue": "VCS_DCM0", "Callouts": [ 3168 { 3169 "CalloutList": [ 3170 { "Priority": "high", "LocCode": "P0-C14" }, 3171 { "Priority": "medium", "LocCode": "P0-C15" }, 3172 { "Priority": "low", "LocCode": "P0" } 3173 ] 3174 } 3175 ] 3176 }, 3177 { 3178 "ADValue": "VCS_DCM1", "Callouts": [ 3179 { 3180 "CalloutList": [ 3181 { "Priority": "high", "LocCode": "P0-C23" }, 3182 { "Priority": "medium", "LocCode": "P0-C24" }, 3183 { "Priority": "low", "LocCode": "P0" } 3184 ] 3185 } 3186 ] 3187 }, 3188 { 3189 "ADValue": "VIO_DCM0", "Callouts": [ 3190 { 3191 "CalloutList": [ 3192 { "Priority": "high", "LocCode": "P0-C14" }, 3193 { "Priority": "medium", "LocCode": "P0-C15" }, 3194 { "Priority": "low", "LocCode": "P0" } 3195 ] 3196 } 3197 ] 3198 }, 3199 { 3200 "ADValue": "VIO_DCM1", "Callouts": [ 3201 { 3202 "CalloutList": [ 3203 { "Priority": "high", "LocCode": "P0-C23" }, 3204 { "Priority": "medium", "LocCode": "P0-C24" }, 3205 { "Priority": "low", "LocCode": "P0" } 3206 ] 3207 } 3208 ] 3209 }, 3210 { 3211 "ADValue": "VPCIE_DCM0", "Callouts": [ 3212 { 3213 "CalloutList": [ 3214 { "Priority": "high", "LocCode": "P0-C14" }, 3215 { "Priority": "medium", "LocCode": "P0-C15" }, 3216 { "Priority": "low", "LocCode": "P0" } 3217 ] 3218 } 3219 ] 3220 }, 3221 { 3222 "ADValue": "VPCIE_DCM1", "Callouts": [ 3223 { 3224 "CalloutList": [ 3225 { "Priority": "high", "LocCode": "P0-C23" }, 3226 { "Priority": "medium", "LocCode": "P0-C24" }, 3227 { "Priority": "low", "LocCode": "P0" } 3228 ] 3229 } 3230 ] 3231 } 3232 ] 3233 }, 3234 3235 "Documentation": { 3236 "Description": "The power sequencer chip detected a voltage fault", 3237 "Message": "The power sequencer chip detected a voltage fault", 3238 "Notes": [ 3239 ] 3240 } 3241 }, 3242 3243 { 3244 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 3245 "Subsystem": "power", 3246 "Severity": "predictive_redundancy_loss", 3247 "ComponentID": "0x2700", 3248 3249 "SRC": { 3250 "Type": "11", 3251 "ReasonCode": "0x2700", 3252 "Words6To9": {} 3253 }, 3254 3255 "Documentation": { 3256 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 3257 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 3258 "Notes": [ 3259 "CALLOUT_INVENTORY_PATH should be specified in the ", 3260 "AdditionalData property of the event log so that ", 3261 "the device is called out but not the communication path." 3262 ] 3263 } 3264 }, 3265 3266 { 3267 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 3268 "Subsystem": "power", 3269 "Severity": "non_error", 3270 "MfgSeverity": "predictive_redundancy_loss", 3271 "ActionFlags": ["report"], 3272 "MfgActionFlags": ["service_action", "report", "call_home"], 3273 "ComponentID": "0x2700", 3274 3275 "SRC": { 3276 "Type": "11", 3277 "ReasonCode": "0x2701", 3278 "Words6To9": {} 3279 }, 3280 3281 "Documentation": { 3282 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 3283 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 3284 "Notes": [ 3285 "CALLOUT_INVENTORY_PATH should be specified in the ", 3286 "AdditionalData property of the event log so that ", 3287 "the device is called out but not the communication path." 3288 ] 3289 } 3290 }, 3291 3292 { 3293 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 3294 "Subsystem": "power", 3295 "ComponentID": "0x2700", 3296 3297 "SRC": { 3298 "Type": "11", 3299 "ReasonCode": "0x2900", 3300 "Words6To9": {} 3301 }, 3302 3303 "Documentation": { 3304 "Description": "A write verification error occurred on a device", 3305 "Message": "A write verification error occurred on a device", 3306 "Notes": [ 3307 "This error occurs when a device register is written, ", 3308 "read back, and the two values do not match. This is ", 3309 "also called a read-back error. The device should be ", 3310 "identified using the CALLOUT_DEVICE_PATH or ", 3311 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 3312 "AdditionalData property of the event log. This will ", 3313 "cause the device and the hardware in the communication ", 3314 "path to be called out." 3315 ] 3316 } 3317 }, 3318 3319 { 3320 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Discharging", 3321 "Subsystem": "power", 3322 "Severity": "non_error", 3323 "ActionFlags": ["report"], 3324 "ComponentID": "0x2700", 3325 3326 "SRC": { 3327 "Type": "11", 3328 "ReasonCode": "0x4201", 3329 "Words6To9": {} 3330 }, 3331 3332 "Documentation": { 3333 "Description": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 3334 "Message": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 3335 "Notes": [ 3336 ] 3337 } 3338 }, 3339 3340 { 3341 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Low", 3342 "Subsystem": "power", 3343 "Severity": "non_error", 3344 "ActionFlags": ["report"], 3345 "ComponentID": "0x2700", 3346 3347 "SRC": { 3348 "Type": "11", 3349 "ReasonCode": "0x4203", 3350 "Words6To9": {} 3351 }, 3352 3353 "Documentation": { 3354 "Description": "The Uninterruptible Power Supply (UPS) battery level is low", 3355 "Message": "The Uninterruptible Power Supply (UPS) battery level is low", 3356 "Notes": [ 3357 ] 3358 } 3359 }, 3360 3361 { 3362 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 3363 "Subsystem": "power", 3364 "ComponentID": "0x2700", 3365 3366 "SRC": { 3367 "Type": "11", 3368 "ReasonCode": "0xA013", 3369 "Words6To9": {} 3370 }, 3371 3372 "Callouts": [ 3373 { 3374 "CalloutList": [ 3375 { "Priority": "high", "Procedure": "bmc_code" } 3376 ] 3377 } 3378 ], 3379 3380 "Documentation": { 3381 "Description": "A regulators configuration file error occurred", 3382 "Message": "A regulators configuration file error occurred", 3383 "Notes": [ 3384 "The regulators configuration file could not be found, ", 3385 "could not be read, or had invalid contents." 3386 ] 3387 } 3388 }, 3389 3390 { 3391 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 3392 "Subsystem": "power", 3393 "Severity": "critical_system_term", 3394 "ComponentID": "0x2700", 3395 3396 "SRC": { 3397 "Type": "11", 3398 "ReasonCode": "0xA014", 3399 "Words6To9": {} 3400 }, 3401 3402 "Callouts": [ 3403 { 3404 "CalloutList": [ 3405 { "Priority": "high", "Procedure": "bmc_code" } 3406 ] 3407 } 3408 ], 3409 3410 "Documentation": { 3411 "Description": "A critical regulators configuration file error occurred", 3412 "Message": "A critical regulators configuration file error occurred", 3413 "Notes": [ 3414 "The regulators configuration file could not be found, ", 3415 "could not be read, or had invalid contents. As a result ", 3416 "voltage regulators could not be configured, and the ", 3417 "chassis could not be powered on." 3418 ] 3419 } 3420 }, 3421 3422 { 3423 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 3424 "Subsystem": "power_sequencer", 3425 "ComponentID": "0x2700", 3426 3427 "SRC": { 3428 "Type": "11", 3429 "ReasonCode": "0xD000", 3430 "Words6To9": {} 3431 }, 3432 3433 "Callouts": [ 3434 { 3435 "CalloutList": [ 3436 { "Priority": "high", "LocCode": "P0" } 3437 ] 3438 } 3439 ], 3440 3441 "Documentation": { 3442 "Description": "The power sequencer chip detected a fault", 3443 "Message": "The power sequencer chip detected a fault", 3444 "Notes": [ 3445 ] 3446 } 3447 }, 3448 3449 { 3450 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 3451 "Subsystem": "power_sequencer", 3452 "ComponentID": "0x2700", 3453 "Severity": "critical", 3454 3455 "SRC": { 3456 "Type": "11", 3457 "ReasonCode": "0xD002", 3458 "Words6To9": {} 3459 }, 3460 3461 "Callouts": [ 3462 { 3463 "CalloutList": [ 3464 { "Priority": "high", "LocCode": "P0" } 3465 ] 3466 } 3467 ], 3468 3469 "Documentation": { 3470 "Description": "System power failed to turn on within timeout period", 3471 "Message": "System power failed to turn on within timeout period", 3472 "Notes": [ 3473 ] 3474 } 3475 }, 3476 3477 { 3478 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 3479 "Subsystem": "power_sequencer", 3480 "ComponentID": "0x2700", 3481 "Severity": "critical", 3482 3483 "SRC": { 3484 "Type": "11", 3485 "ReasonCode": "0xD008", 3486 "Words6To9": {} 3487 }, 3488 3489 "Callouts": [ 3490 { 3491 "CalloutList": [ 3492 { "Priority": "high", "LocCode": "P0" } 3493 ] 3494 } 3495 ], 3496 3497 "Documentation": { 3498 "Description": "System power failed to turn off within timeout period", 3499 "Message": "System power failed to turn off within timeout period", 3500 "Notes": [ 3501 ] 3502 } 3503 }, 3504 3505 { 3506 "Name": "xyz.openbmc_project.Power.Error.Internal", 3507 "Subsystem": "power", 3508 "ComponentID": "0x2700", 3509 3510 "SRC": { 3511 "Type": "11", 3512 "ReasonCode": "0xE000", 3513 "Words6To9": {} 3514 }, 3515 3516 "Callouts": [ 3517 { 3518 "CalloutList": [ 3519 { "Priority": "high", "Procedure": "bmc_code" } 3520 ] 3521 } 3522 ], 3523 3524 "Documentation": { 3525 "Description": "An internal firmware error occurred", 3526 "Message": "An internal firmware error occurred", 3527 "Notes": [ 3528 "The error details must be provided in the AdditionalData ", 3529 "property of the event log." 3530 ] 3531 } 3532 }, 3533 3534 { 3535 "Name": "xyz.openbmc_project.Power.Error.I2C", 3536 "Subsystem": "cec_i2c", 3537 "ComponentID": "0x2700", 3538 3539 "SRC": { 3540 "Type": "11", 3541 "ReasonCode": "0xE100", 3542 "Words6To9": {} 3543 }, 3544 3545 "Documentation": { 3546 "Description": "An I2C error occurred communicating with a device", 3547 "Message": "An I2C error occurred communicating with a device", 3548 "Notes": [ 3549 "The device should be identified using the ", 3550 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 3551 "keywords in the AdditionalData property of the event ", 3552 "log. This will cause the device and the hardware in the ", 3553 "communication path to be called out." 3554 ] 3555 } 3556 }, 3557 3558 { 3559 "Name": "xyz.openbmc_project.Power.Error.PMBus", 3560 "Subsystem": "power", 3561 "ComponentID": "0x2700", 3562 3563 "SRC": { 3564 "Type": "11", 3565 "ReasonCode": "0xE200", 3566 "Words6To9": {} 3567 }, 3568 3569 "Documentation": { 3570 "Description": "A PMBus error occurred on a device", 3571 "Message": "A PMBus error occurred on a device", 3572 "Notes": [ 3573 "This error occurs when the I2C communication was ", 3574 "successful, but the PMBus value read is invalid or ", 3575 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 3576 "in the AdditionalData property of the event log so that ", 3577 "the device is called out but not the communication path." 3578 ] 3579 } 3580 }, 3581 3582 { 3583 "Name": "xyz.openbmc_project.Power.Error.DBus", 3584 "Subsystem": "power", 3585 "ComponentID": "0x2700", 3586 3587 "SRC": { 3588 "Type": "11", 3589 "ReasonCode": "0xE300", 3590 "Words6To9": {} 3591 }, 3592 3593 "Callouts": [ 3594 { 3595 "CalloutList": [ 3596 { "Priority": "high", "Procedure": "bmc_code" } 3597 ] 3598 } 3599 ], 3600 3601 "Documentation": { 3602 "Description": "A firmware inter-process communication (D-Bus) error occurred", 3603 "Message": "A firmware inter-process communication (D-Bus) error occurred" 3604 } 3605 }, 3606 3607 { 3608 "Name": "xyz.openbmc_project.Fan.Error.Fault", 3609 "Subsystem": "power_fans", 3610 "ComponentID": "0x2800", 3611 3612 "SRC": { 3613 "Type": "11", 3614 "ReasonCode": "0x76F0", 3615 "Words6To9": {} 3616 }, 3617 3618 "Documentation": { 3619 "Description": "Fan rotor fault", 3620 "Message": "Fan rotor fault", 3621 "Notes": [ 3622 "This error occurs when a fan rotor has been faulted for a ", 3623 "certain amount of time. The callout is the fan which is ", 3624 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 3625 "passed in during creation and will be either informational ", 3626 "or unrecoverable. The action flags use the defaults and ", 3627 "vary based on the severity." 3628 ] 3629 } 3630 }, 3631 3632 { 3633 "Name": "xyz.openbmc_project.Fan.Error.Missing", 3634 "Subsystem": "power_fans", 3635 "ComponentID": "0x2800", 3636 "Severity": "unrecoverable_redundancy_loss", 3637 "ActionFlags": ["service_action", "report", "call_home"], 3638 3639 "SRC": { 3640 "Type": "11", 3641 "ReasonCode": "0x76F1", 3642 "Words6To9": {} 3643 }, 3644 3645 "Callouts": [ 3646 { 3647 "System": "ibm,rainier", 3648 "CalloutList": [ 3649 { 3650 "Priority": "high", 3651 "SymbolicFRUTrusted": "air_mover", 3652 "UseInventoryLocCode": true 3653 }, 3654 { 3655 "Priority": "low", 3656 "LocCode": "P0" 3657 } 3658 ] 3659 }, 3660 { 3661 "System": "ibm,everest", 3662 "CalloutList": [ 3663 { 3664 "Priority": "high", 3665 "SymbolicFRUTrusted": "air_mover", 3666 "UseInventoryLocCode": true 3667 }, 3668 { 3669 "Priority": "low", 3670 "LocCode": "P1" 3671 } 3672 ] 3673 } 3674 ], 3675 3676 "Documentation": { 3677 "Description": "A fan is missing", 3678 "Message": "A fan is missing", 3679 "Notes": [ 3680 "This error occurs when a fan has been missing for a ", 3681 "certain amount of time. The first callout is the ", 3682 "symbolic FRU AIR_MOVR that has the trusted fan location ", 3683 "code, which it gets using the passed in ", 3684 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 3685 "where the controller and GPIO expander are." 3686 ] 3687 } 3688 }, 3689 3690 { 3691 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 3692 "ComponentID": "0x2800", 3693 "Subsystem": "power_fans", 3694 "Severity": "non_error", 3695 "ActionFlags": ["report"], 3696 "MfgSeverity": "predictive", 3697 "MfgActionFlags": ["service_action", "report"], 3698 3699 "SRC": { 3700 "Type": "11", 3701 "ReasonCode": "0x76F2", 3702 "Words6To9": {} 3703 }, 3704 3705 "Callouts": [ 3706 { 3707 "System": "ibm,rainier", 3708 "CalloutList": [ 3709 {"Priority": "medium", "LocCode": "P0"} 3710 ] 3711 }, 3712 { 3713 "System": "ibm,everest", 3714 "CalloutList": [ 3715 {"Priority": "medium", "LocCode": "P1"} 3716 ] 3717 } 3718 ], 3719 3720 "Documentation": { 3721 "Description": "Presence detect methods for the same fan disagree", 3722 "Message": "Presence detect methods for the same fan disagree", 3723 "Notes": [ 3724 "This error occurs when there is more than one way to detect", 3725 "fan presence, and they don't all agree. For example, the", 3726 "GPIO says a fan isn't present, but the tach readings are", 3727 "nonzero. This is informational, unless in manufacturing.", 3728 "The fan FRU is passed in as a high priority callout.", 3729 "The FRU the GPIO source is on is called out medium." 3730 ] 3731 } 3732 }, 3733 3734 { 3735 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 3736 "ComponentID": "0x2800", 3737 "Subsystem": "power_fans", 3738 "Severity": "critical_system_term", 3739 "ActionFlags": ["service_action", "report", "call_home"], 3740 3741 "SRC": { 3742 "Type": "11", 3743 "ReasonCode": "0x76F3", 3744 "Words6To9": {} 3745 }, 3746 3747 "Callouts": [ 3748 { 3749 "System": "ibm,rainier", 3750 "CalloutList": [ 3751 {"Priority": "high", "LocCode": "P0-C5"}, 3752 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 3753 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 3754 {"Priority": "low", "LocCode": "P0"} 3755 ] 3756 }, 3757 { 3758 "System": "ibm,everest", 3759 "CalloutList": [ 3760 {"Priority": "high", "LocCode": "P0-C0"}, 3761 {"Priority": "medium", "LocCode": "P1"}, 3762 {"Priority": "low", "LocCode": "P0"} 3763 ] 3764 } 3765 ], 3766 3767 "Documentation": { 3768 "Description": "The fan controller device is offline", 3769 "Message": "The fan controller is offline. The system must be powered off.", 3770 "Notes": [ 3771 "The device that controls the fans is offline so the fan", 3772 "targets and speeds are unknown. The system will be shut", 3773 "down to preserve thermal safety. There may be an I2C", 3774 "or power problem with the device." 3775 ] 3776 } 3777 }, 3778 3779 { 3780 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 3781 "Subsystem": "power_fans", 3782 "ComponentID": "0x2800", 3783 "Severity": "unrecoverable_redundancy_loss", 3784 "ActionFlags": ["service_action", "report", "call_home"], 3785 3786 "SRC": { 3787 "Type": "11", 3788 "ReasonCode": "0x76F4", 3789 "Words6To9": {} 3790 }, 3791 3792 "Callouts": [ 3793 { 3794 "System" : "ibm,rainier", 3795 "CalloutList": [ 3796 {"Priority": "high", "LocCode": "P0-C5"}, 3797 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 3798 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 3799 {"Priority": "low", "LocCode": "P0"} 3800 ] 3801 }, 3802 { 3803 "System" : "ibm,everest", 3804 "CalloutList": [ 3805 {"Priority": "high", "LocCode": "P0-C0"}, 3806 {"Priority": "medium", "LocCode": "P1"}, 3807 {"Priority": "low", "LocCode": "P0"} 3808 ] 3809 } 3810 ], 3811 3812 "Documentation": { 3813 "Description": "Fan GPIO sensors not present", 3814 "Message": "Fan GPIO sensors not present", 3815 "Notes": [ 3816 "The device that reports fan presence is not functioning." 3817 ] 3818 } 3819 }, 3820 3821 { 3822 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 3823 "Subsystem": "power", 3824 "ComponentID": "0x2800", 3825 "Severity": "predictive", 3826 "ActionFlags": ["service_action", "report"], 3827 3828 "SRC": { 3829 "ReasonCode": "0x2801", 3830 "Words6To9": {} 3831 }, 3832 3833 "CalloutsUsingAD": { 3834 "ADName": "SENSOR_NAME", 3835 "CalloutsWithTheirADValues": [ 3836 { 3837 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3838 "Callouts": [ 3839 { 3840 "CalloutList": [ 3841 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3842 ] 3843 } 3844 ] 3845 } 3846 ], 3847 "CalloutsWhenNoADMatch": [ 3848 { 3849 "CalloutList": [ 3850 { 3851 "Priority": "high", 3852 "SymbolicFRU": "overtemp" 3853 } 3854 ] 3855 } 3856 ] 3857 }, 3858 3859 "Documentation": { 3860 "Description": "A temperature sensor exceeded its performance loss threshold.", 3861 "Message": "A temperature sensor exceeded its performance loss threshold.", 3862 "Notes": [ 3863 "A temperature sensor crossed its performance loss threshold value", 3864 "If it is the ambient sensor, then a symbolic FRU will be added.", 3865 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3866 "a FRU callout." 3867 ] 3868 } 3869 }, 3870 3871 { 3872 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 3873 "Subsystem": "power", 3874 "ComponentID": "0x2800", 3875 "Severity": "non_error", 3876 "ActionFlags": ["report"], 3877 "EventType": "env_normal", 3878 3879 "SRC": { 3880 "ReasonCode": "0x2802", 3881 "Words6To9": {} 3882 }, 3883 3884 "CalloutsUsingAD": { 3885 "ADName": "SENSOR_NAME", 3886 "CalloutsWithTheirADValues": [ 3887 { 3888 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3889 "Callouts": [ 3890 { 3891 "CalloutList": [ 3892 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3893 ] 3894 } 3895 ] 3896 } 3897 ] 3898 }, 3899 3900 "Documentation": { 3901 "Description": "A temperature sensor is under its performance loss threshold.", 3902 "Message": "A temperature sensor is under its performance loss threshold.", 3903 "Notes": [ 3904 "A temperature sensor crossed under its performance loss threshold value", 3905 "If it is the ambient sensor, then a symbolic FRU will be added." 3906 ] 3907 } 3908 }, 3909 3910 { 3911 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 3912 "Subsystem": "power", 3913 "ComponentID": "0x2800", 3914 "Severity": "predictive", 3915 "ActionFlags": ["service_action", "report"], 3916 3917 "SRC": { 3918 "ReasonCode": "0x2803", 3919 "Words6To9": {} 3920 }, 3921 3922 "CalloutsUsingAD": { 3923 "ADName": "SENSOR_NAME", 3924 "CalloutsWithTheirADValues": [ 3925 { 3926 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3927 "Callouts": [ 3928 { 3929 "CalloutList": [ 3930 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3931 ] 3932 } 3933 ] 3934 } 3935 ], 3936 "CalloutsWhenNoADMatch": [ 3937 { 3938 "CalloutList": [ 3939 { 3940 "Priority": "high", 3941 "SymbolicFRU": "overtemp" 3942 } 3943 ] 3944 } 3945 ] 3946 }, 3947 3948 "Documentation": { 3949 "Description": "A temperature sensor exceeded its warning threshold.", 3950 "Message": "A temperature sensor exceeded its warning threshold.", 3951 "Notes": [ 3952 "A temperature sensor crossed its warning threshold value", 3953 "If it is the ambient sensor, then a symbolic FRU will be added.", 3954 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3955 "a FRU callout." 3956 ] 3957 } 3958 }, 3959 3960 { 3961 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 3962 "Subsystem": "power", 3963 "ComponentID": "0x2800", 3964 "Severity": "non_error", 3965 "ActionFlags": ["report"], 3966 "EventType": "env_normal", 3967 3968 "SRC": { 3969 "ReasonCode": "0x2804", 3970 "Words6To9": {} 3971 }, 3972 3973 "CalloutsUsingAD": { 3974 "ADName": "SENSOR_NAME", 3975 "CalloutsWithTheirADValues": [ 3976 { 3977 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3978 "Callouts": [ 3979 { 3980 "CalloutList": [ 3981 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3982 ] 3983 } 3984 ] 3985 } 3986 ] 3987 }, 3988 3989 "Documentation": { 3990 "Description": "A temperature sensor is under its warning threshold.", 3991 "Message": "A temperature sensor is under its warning threshold.", 3992 "Notes": [ 3993 "A temperature sensor crossed under its warning threshold value", 3994 "If it is the ambient sensor, then a symbolic FRU will be added." 3995 ] 3996 } 3997 }, 3998 3999 { 4000 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 4001 "Subsystem": "power", 4002 "ComponentID": "0x2800", 4003 "Severity": "predictive", 4004 "ActionFlags": ["service_action", "report"], 4005 4006 "SRC": { 4007 "ReasonCode": "0x2805", 4008 "Words6To9": {} 4009 }, 4010 4011 "CalloutsUsingAD": { 4012 "ADName": "SENSOR_NAME", 4013 "CalloutsWithTheirADValues": [ 4014 { 4015 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 4016 "Callouts": [ 4017 { 4018 "CalloutList": [ 4019 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 4020 ] 4021 } 4022 ] 4023 } 4024 ], 4025 "CalloutsWhenNoADMatch": [ 4026 { 4027 "CalloutList": [ 4028 { 4029 "Priority": "high", 4030 "SymbolicFRU": "overtemp" 4031 } 4032 ] 4033 } 4034 ] 4035 }, 4036 4037 "Documentation": { 4038 "Description": "A temperature sensor exceeded its critical threshold.", 4039 "Message": "A temperature sensor exceeded its critical threshold.", 4040 "Notes": [ 4041 "A temperature sensor crossed its critical threshold value", 4042 "If it is the ambient sensor, then a symbolic FRU will be added.", 4043 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 4044 "a FRU callout." 4045 ] 4046 } 4047 }, 4048 4049 { 4050 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 4051 "Subsystem": "power", 4052 "ComponentID": "0x2800", 4053 "Severity": "non_error", 4054 "ActionFlags": ["report"], 4055 "EventType": "env_normal", 4056 4057 "SRC": { 4058 "ReasonCode": "0x2806", 4059 "Words6To9": {} 4060 }, 4061 4062 "CalloutsUsingAD": { 4063 "ADName": "SENSOR_NAME", 4064 "CalloutsWithTheirADValues": [ 4065 { 4066 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 4067 "Callouts": [ 4068 { 4069 "CalloutList": [ 4070 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 4071 ] 4072 } 4073 ] 4074 } 4075 ] 4076 }, 4077 4078 "Documentation": { 4079 "Description": "A temperature sensor is under its critical threshold.", 4080 "Message": "A temperature sensor is under its critical threshold.", 4081 "Notes": [ 4082 "A temperature sensor crossed under its critical threshold value", 4083 "If it is the ambient sensor, then a symbolic FRU will be added." 4084 ] 4085 } 4086 }, 4087 4088 { 4089 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 4090 "Subsystem": "power", 4091 "ComponentID": "0x2800", 4092 "Severity": "predictive", 4093 "ActionFlags": ["service_action", "report"], 4094 4095 "SRC": { 4096 "ReasonCode": "0x2807", 4097 "Words6To9": {} 4098 }, 4099 4100 "Callouts": [ 4101 { 4102 "CalloutList": [ 4103 { 4104 "Priority": "high", 4105 "SymbolicFRU": "ambient_temp" 4106 } 4107 ] 4108 } 4109 ], 4110 4111 "Documentation": { 4112 "Description": "The ambient temperature passed the EPOW3 limit.", 4113 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 4114 "Notes": [ 4115 "This error occurs when the ambient temperature surpassed", 4116 "the EPOW3 shutdown limit." 4117 ] 4118 } 4119 }, 4120 4121 { 4122 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 4123 "Subsystem": "power", 4124 "ComponentID": "0x2800", 4125 "Severity": "non_error", 4126 "ActionFlags": ["report"], 4127 "EventType": "env_normal", 4128 4129 "SRC": { 4130 "ReasonCode": "0x2808", 4131 "Words6To9": {} 4132 }, 4133 4134 "Callouts": [ 4135 { 4136 "CalloutList": [ 4137 { 4138 "Priority": "high", 4139 "SymbolicFRU": "ambient_temp_back" 4140 } 4141 ] 4142 } 4143 ], 4144 4145 "Documentation": { 4146 "Description": "The ambient temperature is back under the EPOW3 limit.", 4147 "Message": "The ambient temperature is back under the EPOW3 limit." 4148 } 4149 }, 4150 4151 { 4152 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 4153 "Subsystem": "power", 4154 "ComponentID": "0x2800", 4155 "ActionFlags": ["service_action", "report"], 4156 4157 "SRC": { 4158 "ReasonCode": "0x2809", 4159 "Words6To9": {} 4160 }, 4161 4162 "Callouts": [ 4163 { 4164 "CalloutList": [ 4165 { 4166 "Priority": "high", 4167 "SymbolicFRU": "ambient_temp" 4168 } 4169 ] 4170 } 4171 ], 4172 4173 "Documentation": { 4174 "Description": "The ambient temperature passed the EPOW4 limit.", 4175 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 4176 "Notes": [ 4177 "This error occurs when the ambient temperature surpassed", 4178 "the EPOW4 shutdown limit." 4179 ] 4180 } 4181 }, 4182 4183 { 4184 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 4185 "Subsystem": "ext_env", 4186 "ComponentID": "0x2800", 4187 "Severity": "predictive", 4188 "ActionFlags": ["service_action", "report"], 4189 4190 "SRC": { 4191 "ReasonCode": "0x280A", 4192 "Words6To9": {} 4193 }, 4194 4195 "CalloutsUsingAD": { 4196 "ADName": "SENSOR_NAME", 4197 "CalloutsWithTheirADValues": [ 4198 { 4199 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 4200 "Callouts": [ 4201 { 4202 "CalloutList": [ 4203 { "Priority": "high", "SymbolicFRU": "altitude" } 4204 ] 4205 } 4206 ] 4207 } 4208 ] 4209 }, 4210 4211 "Documentation": { 4212 "Description": "An altitude sensor exceeded its warning threshold.", 4213 "Message": "An altitude sensor exceeded its warning threshold.", 4214 "Notes": [ 4215 "The virtual altitude sensor crossed its warning threshold value", 4216 " and a symbolic FRU will be added." 4217 ] 4218 } 4219 }, 4220 4221 { 4222 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 4223 "Subsystem": "ext_env", 4224 "ComponentID": "0x2800", 4225 "Severity": "non_error", 4226 "ActionFlags": ["report"], 4227 "EventType": "env_normal", 4228 4229 "SRC": { 4230 "ReasonCode": "0x280B", 4231 "Words6To9": {} 4232 }, 4233 4234 "Documentation": { 4235 "Description": "An altitude sensor is under its warning threshold.", 4236 "Message": "An altitude sensor is under its warning threshold.", 4237 "Notes": [ 4238 "The virtual altitude sensor is under its warning threshold value", 4239 " and a symbolic FRU will be added." 4240 ] 4241 } 4242 }, 4243 4244 { 4245 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 4246 "Subsystem": "cec_tod", 4247 "ComponentID": "0x2800", 4248 "Severity": "predictive", 4249 "ActionFlags": ["service_action", "report"], 4250 4251 "SRC": { 4252 "ReasonCode": "0x280C", 4253 "Words6To9": {} 4254 }, 4255 4256 "Documentation": { 4257 "Description": "A voltage sensor went below its critical low threshold.", 4258 "Message": "A voltage sensor went below its critical low threshold." 4259 } 4260 }, 4261 4262 { 4263 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 4264 "Subsystem": "cec_tod", 4265 "ComponentID": "0x2800", 4266 "Severity": "non_error", 4267 "ActionFlags": ["report"], 4268 4269 "SRC": { 4270 "ReasonCode": "0x280D", 4271 "Words6To9": {} 4272 }, 4273 4274 "Documentation": { 4275 "Description": "A voltage sensor is over its critical low threshold.", 4276 "Message": "A voltage sensor is over its critical low threshold." 4277 } 4278 }, 4279 4280 { 4281 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLow", 4282 "Subsystem": "power", 4283 "ComponentID": "0x2800", 4284 "Severity": "predictive", 4285 "ActionFlags": ["service_action", "report"], 4286 4287 "SRC": { 4288 "ReasonCode": "0x280E", 4289 "Words6To9": {} 4290 }, 4291 4292 "Documentation": { 4293 "Description": "A temperature sensor is under its low warning threshold.", 4294 "Message": "A temperature sensor is under its low warning threshold.", 4295 "Notes": [ 4296 "A temperature sensor crossed its low warning threshold value", 4297 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 4298 ] 4299 } 4300 }, 4301 4302 { 4303 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLowClear", 4304 "Subsystem": "power", 4305 "ComponentID": "0x2800", 4306 "Severity": "non_error", 4307 "ActionFlags": ["report"], 4308 "EventType": "env_normal", 4309 4310 "SRC": { 4311 "ReasonCode": "0x280F", 4312 "Words6To9": {} 4313 }, 4314 4315 "Documentation": { 4316 "Description": "A temperature sensor is above its low warning threshold.", 4317 "Message": "A temperature sensor is above its low warning threshold.", 4318 "Notes": [ 4319 "A temperature sensor crossed above its low warning threshold value." 4320 ] 4321 } 4322 }, 4323 4324 { 4325 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLow", 4326 "Subsystem": "power", 4327 "ComponentID": "0x2800", 4328 "Severity": "predictive", 4329 "ActionFlags": ["service_action", "report"], 4330 4331 "SRC": { 4332 "ReasonCode": "0x2810", 4333 "Words6To9": {} 4334 }, 4335 4336 "Documentation": { 4337 "Description": "A temperature sensor is under its low critical threshold.", 4338 "Message": "A temperature sensor is under its low critical threshold.", 4339 "Notes": [ 4340 "A temperature sensor crossed its low critical threshold value", 4341 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 4342 ] 4343 } 4344 }, 4345 4346 { 4347 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLowClear", 4348 "Subsystem": "power", 4349 "ComponentID": "0x2800", 4350 "Severity": "non_error", 4351 "ActionFlags": ["report"], 4352 "EventType": "env_normal", 4353 4354 "SRC": { 4355 "ReasonCode": "0x2811", 4356 "Words6To9": {} 4357 }, 4358 4359 "Documentation": { 4360 "Description": "A temperature sensor is over its low critical threshold.", 4361 "Message": "A temperature sensor is over its low critical threshold.", 4362 "Notes": [ 4363 "A temperature sensor crossed above its critical threshold value" 4364 ] 4365 } 4366 }, 4367 4368 { 4369 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 4370 "Subsystem": "cec_vpd", 4371 "ComponentID": "0x4000", 4372 4373 "SRC": { 4374 "ReasonCode": "0x4000", 4375 "Words6To9": 4376 { 4377 "6": 4378 { 4379 "Description": "Errno of the failure.", 4380 "AdditionalDataPropSource": "CALLOUT_ERRNO" 4381 } 4382 } 4383 }, 4384 4385 "Documentation": { 4386 "Description": "A path access error occurred", 4387 "Message": "An EEPROM path access error occurred.", 4388 "Notes": [ 4389 "This error occurs when parser is unable to access", 4390 "EEPROM path. Errno and device path are captured as", 4391 "additional data." 4392 ] 4393 } 4394 }, 4395 4396 { 4397 "Name": "com.ibm.VPD.Error.InvalidVPD", 4398 "Subsystem": "cec_vpd", 4399 "ComponentID": "0x4000", 4400 4401 "SRC": { 4402 "ReasonCode": "0x4001", 4403 "Words6To9": 4404 { 4405 } 4406 }, 4407 4408 "Documentation": { 4409 "Description": "Invalid VPD data.", 4410 "Message": "A VPD data exception occurred.", 4411 "Notes": [ 4412 "This error occurs when VPD data is found to be", 4413 "invalid. This can be when VPD file is missing out", 4414 "mandatory records.Inventory path is captured in", 4415 "additional data." 4416 ] 4417 } 4418 }, 4419 4420 { 4421 "Name": "com.ibm.VPD.Error.EccCheckFailed", 4422 "Subsystem": "cec_vpd", 4423 "ComponentID": "0x4000", 4424 4425 "SRC": { 4426 "ReasonCode": "0x4002", 4427 "Words6To9": 4428 { 4429 } 4430 }, 4431 4432 "Documentation": { 4433 "Description": "Invalid VPD ecc data.", 4434 "Message": "A VPD ecc exception occurred.", 4435 "Notes": [ 4436 "This error occurs when VPD ecc check fails for the FRU.", 4437 "Inventory path for the failed FRU is captured in additonal", 4438 "data." 4439 ] 4440 } 4441 }, 4442 4443 { 4444 "Name": "com.ibm.VPD.Error.InvalidJson", 4445 "Subsystem": "cec_vpd", 4446 "ComponentID": "0x4000", 4447 4448 "SRC": { 4449 "ReasonCode": "0x4003", 4450 "Words6To9": 4451 { 4452 } 4453 }, 4454 4455 "Callouts": [ 4456 { 4457 "CalloutList": [ 4458 { "Priority": "high", "Procedure": "bmc_code" } 4459 ] 4460 } 4461 ], 4462 4463 "Documentation": { 4464 "Description": "Invalid Json", 4465 "Message": "A Json failure occurred.", 4466 "Notes": [ 4467 "This error occurs when parser fails to access", 4468 "Json file or there is any issue with Json data.", 4469 "Failed Json path and cause of failure is captured", 4470 "in additional data." 4471 ] 4472 } 4473 }, 4474 4475 { 4476 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 4477 "Subsystem": "cec_vpd", 4478 "ComponentID": "0x4000", 4479 4480 "SRC": { 4481 "ReasonCode": "0x4004", 4482 "Words6To9": 4483 { 4484 } 4485 }, 4486 4487 "Documentation": { 4488 "Description": "System VPD restore failed", 4489 "Message": "A system VPD restoration error occurred.", 4490 "Notes": [ 4491 "This error occurs when restoring of system VPD fails.", 4492 "The FRU path and reason for failure is captured in", 4493 "additional data." 4494 ] 4495 } 4496 }, 4497 4498 { 4499 "Name": "com.ibm.VPD.Error.DbusFailure", 4500 "Subsystem": "cec_vpd", 4501 "ComponentID": "0x4000", 4502 4503 "SRC": { 4504 "ReasonCode": "0x4005", 4505 "Words6To9": 4506 { 4507 } 4508 }, 4509 4510 "Callouts": [ 4511 { 4512 "CalloutList": [ 4513 { "Priority": "high", "Procedure": "bmc_code" } 4514 ] 4515 } 4516 ], 4517 4518 "Documentation": { 4519 "Description": "Dbus exception", 4520 "Message": "A Dbus internal error occurred.", 4521 "Notes": [ 4522 "This error occurs when Dbus operation fails.", 4523 "Exceptions details are captured in additonal", 4524 "data." 4525 ] 4526 } 4527 }, 4528 4529 { 4530 "Name": "com.ibm.VPD.Error.UnknownSystemType", 4531 "Subsystem": "cec_vpd", 4532 "ComponentID": "0x4000", 4533 4534 "SRC": { 4535 "ReasonCode": "0x4006", 4536 "Words6To9": 4537 { 4538 } 4539 }, 4540 4541 "Callouts": [ 4542 { 4543 "CalloutList": [ 4544 { "Priority": "high", "LocCode": "P0" } 4545 ] 4546 } 4547 ], 4548 4549 "Documentation": { 4550 "Description": "Unknown System Type", 4551 "Message": "System type not supported in DTB table.", 4552 "Notes": [ 4553 "System type comes from combination of HW and IM value of system VPD.", 4554 "If anything gets changed in that combination, then it can't determine", 4555 "the appropriate DTB for that system. Need to check HW and IM keywords." 4556 ] 4557 } 4558 }, 4559 4560 { 4561 "Name": "com.ibm.VPD.Error.GPIOError", 4562 "Subsystem": "cec_vpd", 4563 "ComponentID": "0x4000", 4564 4565 "SRC": { 4566 "ReasonCode": "0x4007", 4567 "Words6To9": 4568 { 4569 } 4570 }, 4571 4572 "Callouts": [ 4573 { 4574 "CalloutList": [ 4575 { "Priority": "high", "Procedure": "bmc_code" } 4576 ] 4577 } 4578 ], 4579 4580 "Documentation": { 4581 "Description": "GPIO line error", 4582 "Message": "GPIO line couldn't be found or read.", 4583 "Notes": [ 4584 "The BMC could not access a GPIO line. This can be a hardware issue", 4585 " or driver issue. Since a hardware or a software issue cannot be", 4586 " differentiated, the BMC code will be called out." 4587 ] 4588 } 4589 }, 4590 4591 { 4592 "Name": "com.ibm.VPD.Error.SystemVPDMismatch", 4593 "Subsystem": "cec_vpd", 4594 "ComponentID": "0x4000", 4595 4596 "SRC": { 4597 "ReasonCode": "0x4008", 4598 "Words6To9": 4599 { 4600 } 4601 }, 4602 4603 "Callouts": [ 4604 { 4605 "CalloutList": [ 4606 { "Priority": "high", "Procedure": "bmc_code" } 4607 ] 4608 } 4609 ], 4610 4611 "Documentation": { 4612 "Description": "System VPD restore failed", 4613 "Message": "A system VPD restoration error occurred.", 4614 "Notes": [ 4615 "This error occurs when restoring of system VPD fails due to", 4616 "mismatch in cache data and hardware data.", 4617 "The record and keyword causing the failure is captured in", 4618 "additional data." 4619 ] 4620 } 4621 }, 4622 4623 { 4624 "Name": "com.ibm.VPD.Error.RequiredFRUMissing", 4625 "Subsystem": "cec_vpd", 4626 "ComponentID": "0x4000", 4627 4628 "SRC": { 4629 "ReasonCode": "0x4009", 4630 "Words6To9": 4631 { 4632 } 4633 }, 4634 4635 "Documentation": { 4636 "Description": "Essential FRU check.", 4637 "Message": "Essential FRU check failed", 4638 "Notes": [ 4639 "This error occurs when VPD manager service detects any", 4640 "missing essential FRU. These are FRUs which are required", 4641 "to be present in the system at the time of power on.", 4642 "The inventory path is captured in additional data." 4643 ] 4644 } 4645 }, 4646 4647 { 4648 "Name": "com.ibm.Panel.Error.InputDevPathFailure", 4649 "Subsystem": "cec_op_panel", 4650 "ComponentID": "0x5000", 4651 4652 "SRC": { 4653 "ReasonCode": "0x5001", 4654 "Words6To9": {} 4655 }, 4656 4657 "Documentation": { 4658 "Description": "Button Handler Failure", 4659 "Message": "Input Device path failure", 4660 "Notes": [ 4661 "Button events will not be processed." 4662 ] 4663 } 4664 }, 4665 4666 { 4667 "Name": "com.ibm.Panel.Error.I2CSetupFailure", 4668 "Subsystem": "cec_op_panel", 4669 "ComponentID": "0x5000", 4670 4671 "SRC": { 4672 "ReasonCode": "0x5002", 4673 "Words6To9": {} 4674 }, 4675 4676 "Documentation": { 4677 "Description": "Panel I2C setup failure", 4678 "Message": "Unable to open device path or ioctl failure", 4679 "Notes": [ 4680 "The Panel is unable to open device", 4681 " path or ioctl failure" 4682 ] 4683 } 4684 }, 4685 4686 { 4687 "Name": "com.ibm.Panel.Error.HostCommunicationError", 4688 "Subsystem": "cec_op_panel", 4689 "ComponentID": "0x5000", 4690 4691 "SRC": { 4692 "ReasonCode": "0x5003", 4693 "Words6To9": {} 4694 }, 4695 4696 "Callouts": [{ 4697 "CalloutList": [{ 4698 "Priority": "high", 4699 "Procedure": "bmc_code" 4700 }] 4701 }], 4702 4703 "Documentation": { 4704 "Description": "Host Communication failure", 4705 "Message": "Error in sending message to host", 4706 "Notes": [ 4707 "Failure from PLDM sending message to", 4708 "Host" 4709 ] 4710 } 4711 }, 4712 4713 { 4714 "Name": "com.ibm.Panel.Error.DbusError", 4715 "Subsystem": "cec_op_panel", 4716 "ComponentID": "0x5000", 4717 4718 "SRC": { 4719 "ReasonCode": "0x5004", 4720 "Words6To9": {} 4721 }, 4722 4723 "Callouts": [{ 4724 "CalloutList": [{ 4725 "Priority": "high", 4726 "Procedure": "bmc_code" 4727 }] 4728 }], 4729 4730 "Documentation": { 4731 "Description": "Dbus exception", 4732 "Message": "A Dbus internal error occurred.", 4733 "Notes": [ 4734 "This error occurs when Dbus operation fails.", 4735 "Exceptions details are captured in additional", 4736 "data." 4737 ] 4738 } 4739 }, 4740 4741 { 4742 "Name": "com.ibm.Panel.Error.CodeUpdateFailure", 4743 "Subsystem": "cec_op_panel", 4744 "ComponentID": "0x5000", 4745 4746 "SRC": { 4747 "ReasonCode": "0x5005", 4748 "Words6To9": {} 4749 }, 4750 4751 "Documentation": { 4752 "Description": "LCD/Bootfail PIC code update failure.", 4753 "Message": "Error while doing LCD/bootfail PIC code update.", 4754 "Notes": [ 4755 "Panel firmware(LCD/bootfail PIC) update fails due to ", 4756 "unsupportable firmware version. Inventory path to the", 4757 "FRU on which PIC controller is physically present will", 4758 "be called out." 4759 ] 4760 } 4761 }, 4762 4763 { 4764 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 4765 "Subsystem": "cec_sp_hostboot_iface", 4766 4767 "SRC": 4768 { 4769 "ReasonCode": "0xC101", 4770 "Words6To9": 4771 { 4772 } 4773 }, 4774 4775 "Documentation": 4776 { 4777 "Description": "Host did not respond within the watchdog timeout interval", 4778 "Message": "Host did not respond before the watchdog timeout interval expired", 4779 "Notes": [ 4780 "Host did not respond before the expiry of the watchdog timeout interval.", 4781 "Collecting hostboot dump." 4782 ] 4783 } 4784 }, 4785 4786 { 4787 "Name": "xyz.openbmc_project.Software.Version.Error.Incompatible", 4788 "Subsystem": "bmc_firmware", 4789 "ComponentID": "0x3600", 4790 "SRC": 4791 { 4792 "ReasonCode": "0x3601", 4793 "Words6To9": 4794 { 4795 } 4796 }, 4797 4798 "Callouts": [ 4799 { 4800 "CalloutList": [ 4801 { "Priority": "high", "Procedure": "bmc_code" } 4802 ] 4803 } 4804 ], 4805 4806 "Documentation": 4807 { 4808 "Description": "A system component has a software version that is incompatible.", 4809 "Message": "A system component has a software version that is incompatible." 4810 } 4811 }, 4812 4813 { 4814 "Name": "xyz.openbmc_project.Software.Version.Error.AlreadyExists", 4815 "Subsystem": "bmc_firmware", 4816 "ComponentID": "0x3600", 4817 "SRC": 4818 { 4819 "ReasonCode": "0x3602", 4820 "Words6To9": 4821 { 4822 } 4823 }, 4824 4825 "Callouts": [ 4826 { 4827 "CalloutList": [ 4828 { "Priority": "high", "Procedure": "bmc_code" } 4829 ] 4830 } 4831 ], 4832 4833 "Documentation": 4834 { 4835 "Description": "This image version already exists on the device.", 4836 "Message": "This image version already exists on the device." 4837 } 4838 }, 4839 4840 { 4841 "Name": "xyz.openbmc_project.Software.Image.Error.UnTarFailure", 4842 "Subsystem": "bmc_firmware", 4843 "ComponentID": "0x3600", 4844 "SRC": 4845 { 4846 "ReasonCode": "0x3603", 4847 "Words6To9": 4848 { 4849 } 4850 }, 4851 4852 "Callouts": [ 4853 { 4854 "CalloutList": [ 4855 { "Priority": "high", "Procedure": "bmc_code" } 4856 ] 4857 } 4858 ], 4859 4860 "Documentation": 4861 { 4862 "Description": "An error occurred during untar.", 4863 "Message": "An error occurred during untar." 4864 } 4865 }, 4866 4867 { 4868 "Name": "xyz.openbmc_project.Software.Image.Error.ManifestFileFailure", 4869 "Subsystem": "bmc_firmware", 4870 "ComponentID": "0x3600", 4871 "SRC": 4872 { 4873 "ReasonCode": "0x3604", 4874 "Words6To9": 4875 { 4876 } 4877 }, 4878 4879 "Callouts": [ 4880 { 4881 "CalloutList": [ 4882 { "Priority": "high", "Procedure": "bmc_code" } 4883 ] 4884 } 4885 ], 4886 4887 "Documentation": 4888 { 4889 "Description": "An error occurred when reading the software image Manifest file.", 4890 "Message": "An error occurred when reading the software image Manifest file." 4891 } 4892 }, 4893 4894 { 4895 "Name": "xyz.openbmc_project.Software.Image.Error.InternalFailure", 4896 "Subsystem": "bmc_firmware", 4897 "ComponentID": "0x3600", 4898 "SRC": 4899 { 4900 "ReasonCode": "0x3605", 4901 "Words6To9": 4902 { 4903 } 4904 }, 4905 4906 "Callouts": [ 4907 { 4908 "CalloutList": [ 4909 { "Priority": "high", "Procedure": "bmc_code" } 4910 ] 4911 } 4912 ], 4913 4914 "Documentation": 4915 { 4916 "Description": "The operation failed internally during processing the image.", 4917 "Message": "The operation failed internally during processing the image." 4918 } 4919 }, 4920 4921 { 4922 "Name": "xyz.openbmc_project.Software.Image.Error.ImageFailure", 4923 "Subsystem": "bmc_firmware", 4924 "ComponentID": "0x3600", 4925 "SRC": 4926 { 4927 "ReasonCode": "0x3606", 4928 "Words6To9": 4929 { 4930 } 4931 }, 4932 4933 "Callouts": [ 4934 { 4935 "CalloutList": [ 4936 { "Priority": "high", "Procedure": "bmc_code" } 4937 ] 4938 } 4939 ], 4940 4941 "Documentation": 4942 { 4943 "Description": "An error occurred processing the image.", 4944 "Message": "An error occurred processing the image." 4945 } 4946 }, 4947 4948 { 4949 "Name": "xyz.openbmc_project.Software.Image.Error.BusyFailure", 4950 "Subsystem": "bmc_firmware", 4951 "ComponentID": "0x3600", 4952 "SRC": 4953 { 4954 "ReasonCode": "0x3607", 4955 "Words6To9": 4956 { 4957 } 4958 }, 4959 4960 "Callouts": [ 4961 { 4962 "CalloutList": [ 4963 { "Priority": "high", "Procedure": "bmc_code" } 4964 ] 4965 } 4966 ], 4967 4968 "Documentation": 4969 { 4970 "Description": "The device is busy during the update.", 4971 "Message": "The device is busy during the update." 4972 } 4973 }, 4974 4975 { 4976 "Name": "xyz.openbmc_project.Software.Version.Error.ExpiredAccessKey", 4977 "Subsystem": "bmc_firmware", 4978 "ComponentID": "0x3600", 4979 "SRC": 4980 { 4981 "ReasonCode": "0x3608", 4982 "Words6To9": 4983 { 4984 } 4985 }, 4986 4987 "Callouts": [ 4988 { 4989 "CalloutList": [ 4990 { "Priority": "high", "Procedure": "bmc_code" } 4991 ] 4992 } 4993 ], 4994 4995 "Documentation": 4996 { 4997 "Description": "The Update Access Key has expired.", 4998 "Message": "The Update Access Key has expired." 4999 } 5000 }, 5001 5002 { 5003 "Name": "xyz.openbmc_project.Software.Version.Error.InvalidSignature", 5004 "Subsystem": "bmc_firmware", 5005 "ComponentID": "0x3600", 5006 "SRC": 5007 { 5008 "ReasonCode": "0x3609", 5009 "Words6To9": 5010 { 5011 } 5012 }, 5013 5014 "Callouts": [ 5015 { 5016 "CalloutList": [ 5017 { "Priority": "high", "Procedure": "bmc_code" } 5018 ] 5019 } 5020 ], 5021 5022 "Documentation": 5023 { 5024 "Description": "The software image has an invalid signature.", 5025 "Message": "The software image has an invalid signature" 5026 } 5027 }, 5028 5029 { 5030 "Name" : "xyz.openbmc_project.Software.Version.Error.HostFile", 5031 "Subsystem" : "bmc_firmware", 5032 "ComponentID" : "0x3600", 5033 5034 "SRC" : 5035 { 5036 "ReasonCode" : "0x360A", 5037 "Words6To9": 5038 { 5039 "6": 5040 { 5041 "Description" : "Size of the current running partition", 5042 "AdditionalDataPropSource" : "CURRENT_FILE_SIZE" 5043 }, 5044 "7": 5045 { 5046 "Description" : "Size of the read only partition", 5047 "AdditionalDataPropSource" : "EXPECTED_FILE_SIZE" 5048 } 5049 } 5050 }, 5051 "Callouts": [ 5052 { 5053 "CalloutList": [ 5054 { "Priority": "high", "Procedure": "bmc_code" } 5055 ] 5056 } 5057 ], 5058 "Documentation" : 5059 { 5060 "Description" : "Corrupted or changed preserved file", 5061 "Message" : "Partition was not preserved on reboot", 5062 "Notes" : [ 5063 "This error may occur if one of the partitions marked", 5064 "PRESERVED is either corrupted, or a change of size is ", 5065 "desired for a particular partition." 5066 ] 5067 } 5068 }, 5069 5070 { 5071 "Name": "xyz.openbmc_project.PLDM.Error.findDumpObjPath.GetManagedObjectsFail", 5072 "Subsystem": "bmc_firmware", 5073 "ComponentID": "0x6000", 5074 "Severity": "predictive", 5075 "SRC": 5076 { 5077 "ReasonCode": "0x6001", 5078 "Words6To9": 5079 { 5080 } 5081 }, 5082 "Callouts": [ 5083 { 5084 "CalloutList": [ 5085 { "Priority": "high", "Procedure": "bmc_code" } 5086 ] 5087 } 5088 ], 5089 5090 "Documentation": 5091 { 5092 "Description": "Failed to get the requested dump object path.", 5093 "Message": "Failed to get the requested dump object path from the system." 5094 } 5095 }, 5096 { 5097 "Name": "xyz.openbmc_project.PLDM.Error.newFileAvailable.NewDumpNotifyFail", 5098 "Subsystem": "bmc_firmware", 5099 "ComponentID": "0x6000", 5100 "Severity": "unrecoverable", 5101 "SRC": 5102 { 5103 "ReasonCode": "0x6002", 5104 "Words6To9": 5105 { 5106 } 5107 }, 5108 "Callouts": [ 5109 { 5110 "CalloutList": [ 5111 { "Priority": "high", "Procedure": "bmc_code" } 5112 ] 5113 } 5114 ], 5115 "Documentation": 5116 { 5117 "Description": "Failed to make a new dump notify request to the dump manager application.", 5118 "Message": "Failed to make a new dump notify request to the dump manager application." 5119 } 5120 }, 5121 { 5122 "Name": "xyz.openbmc_project.PLDM.Error.DumpHandler.getOffloadUriFail", 5123 "Subsystem": "bmc_firmware", 5124 "ComponentID": "0x6000", 5125 "Severity": "unrecoverable", 5126 "SRC": 5127 { 5128 "ReasonCode": "0x6003", 5129 "Words6To9": 5130 { 5131 } 5132 }, 5133 "Callouts": [ 5134 { 5135 "CalloutList": [ 5136 { "Priority": "high", "Procedure": "bmc_code" } 5137 ] 5138 } 5139 ], 5140 "Documentation": 5141 { 5142 "Description": "Failed to get the dump offload URI path from the dump entry.", 5143 "Message": "Failed to get the dump offload URI path from the dump entry." 5144 } 5145 }, 5146 { 5147 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.ResourceDumpFileAckFail", 5148 "Subsystem": "bmc_firmware", 5149 "ComponentID": "0x6000", 5150 "Severity": "non_error", 5151 "SRC": 5152 { 5153 "ReasonCode": "0x6004", 5154 "Words6To9": 5155 { 5156 } 5157 }, 5158 "Callouts": [ 5159 { 5160 "CalloutList": [ 5161 { "Priority": "medium", "Procedure": "bmc_code" } 5162 ] 5163 } 5164 ], 5165 "Documentation": 5166 { 5167 "Description": "The hypervisor rejected the request to initiate a new resource dump.", 5168 "Message": "The hypervisor rejected the request to initiate a new resource dump." 5169 } 5170 }, 5171 { 5172 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.SourceDumpIdResetFail", 5173 "Subsystem": "bmc_firmware", 5174 "ComponentID": "0x6000", 5175 "Severity": "unrecoverable", 5176 "SRC": 5177 { 5178 "ReasonCode": "0x6005", 5179 "Words6To9": 5180 { 5181 } 5182 }, 5183 "Callouts": [ 5184 { 5185 "CalloutList": [ 5186 { "Priority": "high", "Procedure": "bmc_code" } 5187 ] 5188 } 5189 ], 5190 "Documentation": 5191 { 5192 "Description": "Failed to reset the dump ID, due to this requested dump will not be deleted.", 5193 "Message": "Failed to reset the dump ID, due to this requested dump will not be deleted." 5194 } 5195 }, 5196 { 5197 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryDeleteFail", 5198 "Subsystem": "bmc_firmware", 5199 "ComponentID": "0x6000", 5200 "Severity": "unrecoverable", 5201 "SRC": 5202 { 5203 "ReasonCode": "0x6006", 5204 "Words6To9": 5205 { 5206 } 5207 }, 5208 "Callouts": [ 5209 { 5210 "CalloutList": [ 5211 { "Priority": "high", "Procedure": "bmc_code" } 5212 ] 5213 } 5214 ], 5215 "Documentation": 5216 { 5217 "Description": "Failed to carry out the dump delete request from the hypervisor.", 5218 "Message": "Failed to carry out the dump delete request from the hypervisor." 5219 } 5220 }, 5221 { 5222 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryOffloadedSetFail", 5223 "Subsystem": "bmc_firmware", 5224 "ComponentID": "0x6000", 5225 "Severity": "unrecoverable", 5226 "SRC": 5227 { 5228 "ReasonCode": "0x6007", 5229 "Words6To9": 5230 { 5231 } 5232 }, 5233 "Callouts": [ 5234 { 5235 "CalloutList": [ 5236 { "Priority": "high", "Procedure": "bmc_code" } 5237 ] 5238 } 5239 ], 5240 "Documentation": 5241 { 5242 "Description": "Failed to set the dump offloaded completion flag in the dump entry.", 5243 "Message": "Failed to set the dump offloaded completion flag in the dump entry." 5244 } 5245 }, 5246 { 5247 "Name": "xyz.openbmc_project.PLDM.Error.readIntoMemory.GetFilepathFail", 5248 "Subsystem": "bmc_firmware", 5249 "ComponentID": "0x6000", 5250 "Severity": "unrecoverable", 5251 "SRC": 5252 { 5253 "ReasonCode": "0x6008", 5254 "Words6To9": 5255 { 5256 } 5257 }, 5258 "Callouts": [ 5259 { 5260 "CalloutList": [ 5261 { "Priority": "high", "Procedure": "bmc_code" } 5262 ] 5263 } 5264 ], 5265 "Documentation": 5266 { 5267 "Description": "Failed to get the file path for the BMC dump and offload to the hypervisor.", 5268 "Message": "Failed to get the file path for the BMC dump and offload to the hypervisor." 5269 } 5270 }, 5271 { 5272 "Name": "xyz.openbmc_project.PLDM.Error.read.GetFilepathFail", 5273 "Subsystem": "bmc_firmware", 5274 "ComponentID": "0x6000", 5275 "Severity": "unrecoverable", 5276 "SRC": 5277 { 5278 "ReasonCode": "0x6009", 5279 "Words6To9": 5280 { 5281 } 5282 }, 5283 "Callouts": [ 5284 { 5285 "CalloutList": [ 5286 { "Priority": "high", "Procedure": "bmc_code" } 5287 ] 5288 } 5289 ], 5290 "Documentation": 5291 { 5292 "Description": "Failed to get the file path for the BMC dump and offload to the hypervisor.", 5293 "Message": "Failed to get the file path for the BMC dump and offload to the hypervisor." 5294 } 5295 }, 5296 { 5297 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.ResourceDumpFileAckWithMetaDataFail", 5298 "Subsystem": "bmc_firmware", 5299 "ComponentID": "0x6000", 5300 "Severity": "non_error", 5301 "SRC": 5302 { 5303 "ReasonCode": "0x6010", 5304 "Words6To9": 5305 { 5306 } 5307 }, 5308 "Callouts": [ 5309 { 5310 "CalloutList": [ 5311 { "Priority": "medium", "Procedure": "bmc_code" } 5312 ] 5313 } 5314 ], 5315 "Documentation": 5316 { 5317 "Description": "Could not create a new resource dump due to hypervisor verification failed.", 5318 "Message": "Could not create a new resource dump due to hypervisor verification failed." 5319 } 5320 }, 5321 { 5322 "Name": "xyz.openbmc_project.PLDM.Error.fileAckWithMetaData.DumpEntryOffloadedSetFail", 5323 "Subsystem": "bmc_firmware", 5324 "ComponentID": "0x6000", 5325 "Severity": "unrecoverable", 5326 "SRC": 5327 { 5328 "ReasonCode": "0x6011", 5329 "Words6To9": 5330 { 5331 } 5332 }, 5333 "Callouts": [ 5334 { 5335 "CalloutList": [ 5336 { "Priority": "high", "Procedure": "bmc_code" } 5337 ] 5338 } 5339 ], 5340 "Documentation": 5341 { 5342 "Description": "Failed to set the dump offload completion flag in the dump entry details.", 5343 "Message": "Failed to set the dump offload completion flag in the dump entry details." 5344 } 5345 }, 5346 { 5347 "Name": "xyz.openbmc_project.PLDM.Error.newFileAvailableWithMetaData.NewDumpNotifyFail", 5348 "Subsystem": "bmc_firmware", 5349 "ComponentID": "0x6000", 5350 "Severity": "unrecoverable", 5351 "SRC": 5352 { 5353 "ReasonCode": "0x6012", 5354 "Words6To9": 5355 { 5356 } 5357 }, 5358 "Callouts": [ 5359 { 5360 "CalloutList": [ 5361 { "Priority": "high", "Procedure": "bmc_code" } 5362 ] 5363 } 5364 ], 5365 "Documentation": 5366 { 5367 "Description": "Failed to notify a new dump available request.", 5368 "Message": "Failed to notify a new dump available request." 5369 } 5370 }, 5371 { 5372 "Name": "xyz.openbmc_project.PLDM.Error.sendNewFileAvailableCmd.SendDumpParametersFail", 5373 "Subsystem": "bmc_firmware", 5374 "ComponentID": "0x6000", 5375 "Severity": "unrecoverable", 5376 "SRC": 5377 { 5378 "ReasonCode": "0x6013", 5379 "Words6To9": 5380 { 5381 } 5382 }, 5383 "Callouts": [ 5384 { 5385 "CalloutList": [ 5386 { "Priority": "high", "Procedure": "bmc_code" } 5387 ] 5388 } 5389 ], 5390 "Documentation": 5391 { 5392 "Description": "Failed to send the resource dump parameters for a new dump initiation.", 5393 "Message": "Failed to send the resource dump parameters for a new dump initiation." 5394 } 5395 }, 5396 { 5397 "Name": "xyz.openbmc_project.PLDM.Error.SendFileToHostFail", 5398 "Subsystem": "bmc_firmware", 5399 "ComponentID": "0x6000", 5400 "Severity": "unrecoverable", 5401 "SRC": 5402 { 5403 "ReasonCode": "0x6014", 5404 "Words6To9": 5405 { 5406 } 5407 }, 5408 "Callouts": [ 5409 { 5410 "CalloutList": [ 5411 { "Priority": "high", "Procedure": "bmc_code" } 5412 ] 5413 } 5414 ], 5415 "Documentation": 5416 { 5417 "Description": "Failed to send the certificate/license file to the host.", 5418 "Message": "Failed to send the certificate/license file to the host." 5419 } 5420 }, 5421 { 5422 "Name": "xyz.openbmc_project.PLDM.Error.DecodeNewFileResponseFail", 5423 "Subsystem": "bmc_firmware", 5424 "ComponentID": "0x6000", 5425 "Severity": "unrecoverable", 5426 "SRC": 5427 { 5428 "ReasonCode": "0x6015", 5429 "Words6To9": 5430 { 5431 } 5432 }, 5433 "Callouts": [ 5434 { 5435 "CalloutList": [ 5436 { "Priority": "high", "Procedure": "bmc_code" } 5437 ] 5438 } 5439 ], 5440 "Documentation": 5441 { 5442 "Description": "Failed to decode the response of certificate/license file sent to the host.", 5443 "Message": "Failed to decode the response of certificate/license file sent to the host." 5444 } 5445 }, 5446 { 5447 "Name": "xyz.openbmc_project.PLDM.Error.NewFileAvailableRequestFail", 5448 "Subsystem": "bmc_firmware", 5449 "ComponentID": "0x6000", 5450 "Severity": "unrecoverable", 5451 "SRC": 5452 { 5453 "ReasonCode": "0x6016", 5454 "Words6To9": 5455 { 5456 } 5457 }, 5458 "Callouts": [ 5459 { 5460 "CalloutList": [ 5461 { "Priority": "high", "Procedure": "bmc_code" } 5462 ] 5463 } 5464 ], 5465 "Documentation": 5466 { 5467 "Description": "Failed to send the new certificate/license file to the host.", 5468 "Message": "Failed to send the new certificate/license file to the host." 5469 } 5470 }, 5471 { 5472 "Name": "xyz.openbmc_project.PLDM.Error.SetHostEffecterFailed", 5473 "Subsystem": "bmc_firmware", 5474 "ComponentID": "0x6000", 5475 "Severity": "unrecoverable", 5476 "SRC": 5477 { 5478 "ReasonCode": "0x6017", 5479 "Words6To9": 5480 { 5481 } 5482 }, 5483 5484 "Callouts": [ 5485 { 5486 "CalloutList": [ 5487 { "Priority": "high", "Procedure": "bmc_code" } 5488 ] 5489 } 5490 ], 5491 "Documentation": 5492 { 5493 "Description": "Failed to set state effecter states.", 5494 "Message": "Failed to set state effecter states." 5495 } 5496 }, 5497 { 5498 "Name": "xyz.openbmc_project.PLDM.Error.Generate.PDRJsonFileParseFail", 5499 "Subsystem": "bmc_firmware", 5500 "ComponentID": "0x6000", 5501 "Severity": "unrecoverable", 5502 "SRC": 5503 { 5504 "ReasonCode": "0x6018", 5505 "Words6To9": 5506 { 5507 } 5508 }, 5509 "Callouts": [ 5510 { 5511 "CalloutList": [ 5512 { "Priority": "high", "Procedure": "bmc_code" } 5513 ] 5514 } 5515 ], 5516 "Documentation": 5517 { 5518 "Description": "Failed to parse PDR JSON file.", 5519 "Message": "Failed to parse PDR JSON file." 5520 } 5521 }, 5522 { 5523 "Name": "xyz.openbmc_project.PLDM.Error.SetHostSensorState.GetStateSensorPDRFail", 5524 "Subsystem": "bmc_firmware", 5525 "ComponentID": "0x6000", 5526 "Severity": "unrecoverable", 5527 "SRC": 5528 { 5529 "ReasonCode": "0x6019", 5530 "Words6To9": 5531 { 5532 } 5533 }, 5534 "Callouts": [ 5535 { 5536 "CalloutList": [ 5537 { "Priority": "high", "Procedure": "bmc_code" } 5538 ] 5539 } 5540 ], 5541 "Documentation": 5542 { 5543 "Description": "Failed to get state sensor PDR state.", 5544 "Message": "Failed to get state sensor PDR state." 5545 } 5546 }, 5547 { 5548 "Name": "xyz.openbmc_project.PLDM.Error.SetHostSensorState.EncodeStateSensorFail", 5549 "Subsystem": "bmc_firmware", 5550 "ComponentID": "0x6000", 5551 "Severity": "unrecoverable", 5552 "SRC": 5553 { 5554 "ReasonCode": "0x6020", 5555 "Words6To9": 5556 { 5557 } 5558 }, 5559 "Callouts": [ 5560 { 5561 "CalloutList": [ 5562 { "Priority": "high", "Procedure": "bmc_code" } 5563 ] 5564 } 5565 ], 5566 "Documentation": 5567 { 5568 "Description": "Failed to encode state sensor request.", 5569 "Message": "Failed to encode state sensor request." 5570 } 5571 }, 5572 { 5573 "Name": "xyz.openbmc_project.PLDM.Error.CMsubscribeFailure", 5574 "Subsystem": "bmc_firmware", 5575 "ComponentID": "0x6000", 5576 "Severity": "unrecoverable", 5577 "SRC": 5578 { 5579 "ReasonCode": "0x6021", 5580 "Words6To9": 5581 { 5582 } 5583 }, 5584 "Callouts": [ 5585 { 5586 "CalloutList": [ 5587 { "Priority": "high", "Procedure": "bmc_code" } 5588 ] 5589 } 5590 ], 5591 "Documentation": 5592 { 5593 "Description": "Failed to subscribe for concurrent maintenance of FRU.", 5594 "Message": "Failed to subscribe for concurrent maintenance of FRU." 5595 } 5596 }, 5597 { 5598 "Name": "xyz.openbmc_project.PLDM.Error.setSurvTimer.RecvSurveillancePingFail", 5599 "Subsystem": "bmc_firmware", 5600 "ComponentID": "0x6000", 5601 "Severity": "non_error", 5602 "SRC": 5603 { 5604 "ReasonCode": "0x6022", 5605 "Words6To9": 5606 { 5607 } 5608 }, 5609 "Callouts": [ 5610 { 5611 "CalloutList": [ 5612 { "Priority": "high", "Procedure": "bmc_code" } 5613 ] 5614 } 5615 ], 5616 "Documentation": 5617 { 5618 "Description": "Host did not send a surveillance ping within stipulated timeout interval.", 5619 "Message": "Host did not send a surveillance ping within stipulated timeout interval." 5620 } 5621 }, 5622 { 5623 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryOffloadUriSetFail", 5624 "Subsystem": "bmc_firmware", 5625 "ComponentID": "0x6000", 5626 "Severity": "unrecoverable", 5627 "SRC": 5628 { 5629 "ReasonCode": "0x6023", 5630 "Words6To9": 5631 { 5632 } 5633 }, 5634 "Callouts": [ 5635 { 5636 "CalloutList": [ 5637 { "Priority": "high", "Procedure": "bmc_code" } 5638 ] 5639 } 5640 ], 5641 "Documentation": 5642 { 5643 "Description": "Failed to reset the dump offload URI path from the dump entry.", 5644 "Message": "Failed to reset the dump offload URI path from the dump entry." 5645 } 5646 }, 5647 { 5648 "Name": "xyz.openbmc_project.PLDM.Error.SoftPowerOff.HostSoftOffTimeOut", 5649 "Subsystem": "bmc_firmware", 5650 "ComponentID": "0x6000", 5651 "Severity": "unrecoverable", 5652 "SRC": 5653 { 5654 "ReasonCode": "0x6024", 5655 "Words6To9": 5656 { 5657 } 5658 }, 5659 "Callouts": [ 5660 { 5661 "CalloutList": [ 5662 { "Priority": "high", "Procedure": "bmc_code" } 5663 ] 5664 } 5665 ], 5666 "Documentation": 5667 { 5668 "Description": "Host failed to complete the power off gracefully within the timeout.", 5669 "Message": "Host failed to complete the power off gracefully within the timeout." 5670 } 5671 } 5672 ] 5673} 5674