1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 8 "SRC": 9 { 10 "ReasonCode": "0x1001", 11 "Words6To9": 12 { 13 "6": 14 { 15 "Description": "Timeout in ms", 16 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 17 } 18 } 19 }, 20 21 "Documentation": 22 { 23 "Description": "This is a generic timeout error", 24 "Message": "An operation timed out", 25 "Notes": [ 26 "The journal should contain more information" 27 ] 28 } 29 }, 30 31 { 32 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 33 "Subsystem": "bmc_firmware", 34 35 "SRC": 36 { 37 "ReasonCode": "0x1002", 38 "Words6To9": 39 { 40 } 41 }, 42 43 "Documentation": 44 { 45 "Description": "BMC code had a generic internal failure", 46 "Message": "An application had an internal failure", 47 "Notes": [ 48 "The journal should contain more information" 49 ] 50 } 51 }, 52 53 { 54 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 55 "Subsystem": "user_error", 56 57 "SRC": 58 { 59 "ReasonCode": "0x1003", 60 "Words6To9": 61 { 62 } 63 }, 64 65 "Documentation": 66 { 67 "Description": "BMC code was given an invalid argument", 68 "Message": "Code was given an invalid argument", 69 "Notes": [ 70 "The journal should contain more information" 71 ] 72 } 73 }, 74 { 75 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 76 "Subsystem": "user_error", 77 78 "SRC": 79 { 80 "ReasonCode": "0x1004", 81 "Words6To9": 82 { 83 } 84 }, 85 86 "Documentation": 87 { 88 "Description": "An operation failed due to insufficient permission", 89 "Message": "An operation failed due to unsufficient permission", 90 "Notes": [ 91 "The journal should contain more information" 92 ] 93 } 94 }, 95 96 { 97 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 98 "Subsystem": "user_error", 99 100 "SRC": 101 { 102 "ReasonCode": "0x1005", 103 "Words6To9": 104 { 105 } 106 }, 107 108 "Documentation": 109 { 110 "Description": "An operation failed because it isn't allowed", 111 "Message": "An operation failed because it isn't allowed", 112 "Notes": [ 113 "The journal should contain more information" 114 ] 115 } 116 }, 117 118 { 119 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 120 "Subsystem": "user_error", 121 122 "SRC": 123 { 124 "ReasonCode": "0x1006", 125 "Words6To9": 126 { 127 } 128 }, 129 130 "Documentation": 131 { 132 "Description": "The server's CA certificate has not been provided", 133 "Message": "The server's CA certificate has not been provided" 134 } 135 }, 136 137 { 138 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 139 "Subsystem": "cec_chip_iface", 140 141 "SRC": 142 { 143 "ReasonCode": "0x1007", 144 "Words6To9": 145 { 146 "6": 147 { 148 "Description": "errno of the failure", 149 "AdditionalDataPropSource": "CALLOUT_ERRNO" 150 } 151 } 152 }, 153 154 "Documentation": 155 { 156 "Description": "Sensor device read failure", 157 "Message": "There was a failure when reading a sensor device", 158 "Notes": [ 159 "The severity is set by the creator.", 160 "The action flags are set automatically by the code.", 161 "Callouts added based on CALLOUT_DEVICE_PATH." 162 ] 163 } 164 }, 165 166 { 167 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 168 "Subsystem": "cec_chip_iface", 169 170 "SRC": 171 { 172 "ReasonCode": "0x1008", 173 "Words6To9": 174 { 175 "6": 176 { 177 "Description": "errno of the failure", 178 "AdditionalDataPropSource": "CALLOUT_ERRNO" 179 } 180 } 181 }, 182 183 "Documentation": 184 { 185 "Description": "Device read failure", 186 "Message": "There was a failure when reading a hardware device", 187 "Notes": [ 188 "The severity is set by the creator.", 189 "The action flags are set automatically by the code.", 190 "Callouts added based on CALLOUT_DEVICE_PATH." 191 ] 192 } 193 }, 194 195 { 196 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 197 "Subsystem": "cec_chip_iface", 198 199 "SRC": 200 { 201 "ReasonCode": "0x1009", 202 "Words6To9": 203 { 204 "6": 205 { 206 "Description": "errno of the failure", 207 "AdditionalDataPropSource": "CALLOUT_ERRNO" 208 } 209 } 210 }, 211 212 "Documentation": 213 { 214 "Description": "Device write failure", 215 "Message": "There was a failure when writing to a hardware device", 216 "Notes": [ 217 "The severity is set by the creator.", 218 "The action flags are set automatically by the code.", 219 "Callouts added based on CALLOUT_DEVICE_PATH" 220 ] 221 } 222 }, 223 224 { 225 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 226 "Subsystem": "cec_chip_iface", 227 228 "SRC": 229 { 230 "ReasonCode": "0x100A", 231 "Words6To9": 232 { 233 "6": 234 { 235 "Description": "errno of the failure", 236 "AdditionalDataPropSource": "CALLOUT_ERRNO" 237 } 238 } 239 }, 240 241 "Documentation": 242 { 243 "Description": "Device write failure", 244 "Message": "There was a failure when writing to a hardware device", 245 "Notes": [ 246 "The severity is set by the creator.", 247 "The action flags are set automatically by the code.", 248 "Callouts added based on CALLOUT_DEVICE_PATH" 249 ] 250 } 251 }, 252 253 { 254 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 255 "Subsystem": "bmc_firmware", 256 "Severity": "non_error", 257 258 "SRC": 259 { 260 "ReasonCode": "0x2001", 261 "Words6To9": 262 { 263 "6": 264 { 265 "Description": "The bad PEL ID", 266 "AdditionalDataPropSource": "BAD_ID" 267 } 268 } 269 }, 270 271 "Documentation": 272 { 273 "Description": "The BMC sent the host a malformed PEL", 274 "Message": "The BMC sent the host a malformed PEL", 275 "Notes": [ 276 "The host firmware rejected that PEL." 277 ] 278 } 279 }, 280 281 { 282 "Name": "org.open_power.Logging.Error.BadHostPEL", 283 "Subsystem": "platform_firmware", 284 "Severity": "unrecoverable", 285 286 "SRC": 287 { 288 "ReasonCode": "0x2002", 289 "Words6To9": 290 { 291 "6": 292 { 293 "Description": "The PLID of the invalid PEL", 294 "AdditionalDataPropSource": "PLID" 295 }, 296 "7": 297 { 298 "Description": "The corresponding OpenBMC event log ID", 299 "AdditionalDataPropSource": "OBMC_LOG_ID" 300 }, 301 "8": 302 { 303 "Description": "The size of the invalid PEL", 304 "AdditionalDataPropSource": "PEL_SIZE" 305 } 306 } 307 }, 308 309 "Documentation": 310 { 311 "Description": "The host sent the BMC an invalid PEL", 312 "Message": "The host sent the BMC an invalid PEL", 313 "Notes": [ 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.TestError1", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2003", 326 "Words6To9": 327 { 328 } 329 }, 330 331 "Callouts": [ 332 { 333 "CalloutList": [ 334 {"Priority": "high", "Procedure": "bmc_code"}, 335 {"Priority": "medium", "SymbolicFRU": "service_docs"} 336 ] 337 } 338 ], 339 340 "Documentation": 341 { 342 "Description": "An error for testing", 343 "Message": "This is a test error" 344 } 345 }, 346 347 { 348 "Name": "xyz.openbmc_project.Logging.Error.Default", 349 "Subsystem": "other_na", 350 351 "SRC": 352 { 353 "ReasonCode": "0x2004", 354 "Words6To9": 355 { 356 } 357 }, 358 359 "Documentation": 360 { 361 "Description": "This entry is used when no other matching entry is found", 362 "Message": "Unknown (Original event not in message registry)", 363 "Notes": [ 364 "This is used when the actual error name isn't found in ", 365 "the registry. The original error name will be stored ", 366 "in the UserData section that contains the AdditionalData ", 367 "properties using the key ERROR_NAME.", 368 "This error may contain callouts if the creator passed ", 369 "them in.", 370 "The severity is set by the creator.", 371 "If this error is seen, then a code change needs to be ", 372 "made to add the missing error entry to this registry." 373 ] 374 } 375 }, 376 377 { 378 "Name": "org.open_power.PHAL.Error.Boot", 379 "Subsystem": "cec_hardware", 380 "ComponentID": "0x3000", 381 "Severity": "unrecoverable", 382 383 "SRC": 384 { 385 "ReasonCode": "0x3001", 386 "Words6To9": 387 { 388 } 389 }, 390 391 "Documentation": 392 { 393 "Description": "Failure occured during boot process", 394 "Message": "Failure occured during boot process", 395 "Notes": [ 396 "Debug traces will be captured in AdditionalData section" 397 ] 398 } 399 }, 400 401 { 402 "Name": "org.open_power.PHAL.Error.PrePowerOff", 403 "Subsystem": "cec_hardware", 404 "ComponentID": "0x3000", 405 406 "SRC": 407 { 408 "ReasonCode": "0x3002", 409 "Words6To9": 410 { 411 } 412 }, 413 414 "Documentation": 415 { 416 "Description": "Failure occurred during PHAL pre-poweroff operations", 417 "Message": "Failure occurred during PHAL pre-poweroff operations", 418 "Notes": [ 419 "Severity needs to be set based on needs for this registry.", 420 "FFDC (First Failure Data Collection) will be collected ", 421 "and added into PEL." 422 ] 423 } 424 }, 425 426 { 427 "Name": "org.open_power.PHAL.Error.devtreeSync", 428 "Subsystem": "cec_hardware", 429 "ComponentID": "0x3000", 430 "Severity": "unrecoverable", 431 432 "SRC": 433 { 434 "ReasonCode": "0x3003", 435 "Words6To9": 436 { 437 } 438 }, 439 440 "Documentation": 441 { 442 "Description": "Failure occurred during PHAL devtree sync ", 443 "Message": "Failure occurred during PHAL devtree sync", 444 "Notes": [ 445 "The journal should contain more information" 446 ] 447 } 448 }, 449 450 { 451 "Name": "org.open_power.PHAL.Error.devtreeBackup", 452 "Subsystem": "cec_hardware", 453 "ComponentID": "0x3000", 454 "Severity": "unrecoverable", 455 456 "SRC": 457 { 458 "ReasonCode": "0x3004", 459 "Words6To9": 460 { 461 } 462 }, 463 464 "Documentation": 465 { 466 "Description": "Failure occurred during PHAL devtree backup ", 467 "Message": "Failure occurred during PHAL devtree backup", 468 "Notes": [ 469 "The journal should contain more information" 470 ] 471 } 472 }, 473 474 { 475 "Name": "org.open_power.PHAL.Error.HostRunning", 476 "Subsystem": "cec_sp_hostboot_iface", 477 "ComponentID": "0x3000", 478 479 "SRC": 480 { 481 "ReasonCode": "0x3005", 482 "Words6To9": 483 { 484 } 485 }, 486 487 "Documentation": 488 { 489 "Description": "Host did not respond to BMC after a BMC reset", 490 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 491 "Notes": [ 492 "System will be left in its current state to ensure host ", 493 "is not unexpectedly taken down. There is most likely an ", 494 "issue in the software or hardware communication path ", 495 "between the BMC and the Host firmware.", 496 "A BMC dump will be collected with relevant FFDC." 497 ] 498 } 499 }, 500 501 { 502 "Name": "org.open_power.HardwareIsolation.Error", 503 "Subsystem": "cec_hardware", 504 "ComponentID": "0x3100", 505 506 "SRC": 507 { 508 "ReasonCode": "0x3101", 509 "Words6To9": 510 { 511 } 512 }, 513 514 "Documentation": 515 { 516 "Description": "Failure occured during hardware isolation operations", 517 "Message": "Failure occured during hardware isolation operations", 518 "Notes": [ 519 "Severity needs to be set based on needs for this registry.", 520 "Debug traces will be captured in AdditionalData section" 521 ] 522 } 523 }, 524 525 { 526 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 527 "Subsystem": "cec_sp_hostboot_iface", 528 "ComponentID": "0x3400", 529 "SRC": 530 { 531 "ReasonCode": "0x3401", 532 "Words6To9": 533 { 534 } 535 }, 536 "Documentation": 537 { 538 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 539 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 540 "Notes": [ 541 "System will follow recovery policy, resulting in this ", 542 "error and most likely a a reboot of the host. The issue ", 543 "is most likely the result of the BMC rebooting while the ", 544 "host was booting and in a state where it still needed ", 545 "the BMC to complete its boot." 546 ] 547 } 548 }, 549 550 { 551 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 552 "Subsystem": "processor_chip", 553 "ComponentID": "0x3500", 554 555 "SRC": 556 { 557 "ReasonCode": "0x3500", 558 "Words6To9": 559 { 560 "6": 561 { 562 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 563 "AdditionalDataPropSource": "SRC6" 564 } 565 } 566 }, 567 568 "Documentation": 569 { 570 "Description": "chipop failure with SBE provided FFDC", 571 "Message": "chipop request failure reported by SBE", 572 "Notes": [ 573 "The severity is set by the creator.", 574 "Callouts added based on SBE provided FFDC.", 575 "SBE provided additional debug data included as part of the", 576 "additional user data section." 577 ] 578 } 579 }, 580 581 { 582 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 583 "Subsystem": "processor_chip", 584 "ComponentID": "0x3500", 585 586 "SRC": 587 { 588 "ReasonCode": "0x3501", 589 "Words6To9": 590 { 591 "6": 592 { 593 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 594 "AdditionalDataPropSource": "SRC6" 595 } 596 } 597 }, 598 599 "Documentation": 600 { 601 "Description": "SBE chipop timeout", 602 "Message": "chipop timeout reported during SBE communication", 603 "Notes": [ 604 "The severity is set by the creator.", 605 "Check SBE Dump associated to this error to debug the failure." 606 ] 607 } 608 }, 609 610 { 611 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 612 "Subsystem": "processor_chip", 613 "ComponentID": "0x3500", 614 615 "SRC": 616 { 617 "ReasonCode": "0x3502", 618 "Words6To9": 619 { 620 "6": 621 { 622 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 623 "AdditionalDataPropSource": "SRC6" 624 }, 625 "7": 626 { 627 "Description": "Value of SBE state", 628 "AdditionalDataPropSource": "SRC7" 629 } 630 } 631 }, 632 633 "Documentation": 634 { 635 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 636 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 637 "Notes": [ 638 "The severity is set by the creator." 639 ] 640 } 641 }, 642 643 { 644 "Name": "org.open_power.Processor.Error.SbeBootFailure", 645 "Subsystem": "processor_chip", 646 "ComponentID": "0x3500", 647 648 "SRC": 649 { 650 "ReasonCode": "0x3503", 651 "Words6To9": 652 { 653 "6": 654 { 655 "Description": "[0:15] chip position", 656 "AdditionalDataPropSource": "SRC6" 657 } 658 } 659 }, 660 661 "Documentation": 662 { 663 "Description": "Boot failure with SBE provided FFDC", 664 "Message": "Boot failure reported by SBE", 665 "Notes": [ 666 "The severity is set by the creator.", 667 "Callouts added based on SBE provided FFDC.", 668 "SBE provided additional debug data included as part of the", 669 "additional user data section." 670 ] 671 } 672 }, 673 674 { 675 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 676 "Subsystem": "processor_chip", 677 "ComponentID": "0x3500", 678 679 "SRC": 680 { 681 "ReasonCode": "0x3504", 682 "Words6To9": 683 { 684 } 685 }, 686 687 "Documentation": 688 { 689 "Description": "SBE Boot timeout", 690 "Message": "timeout reported during SBE boot process", 691 "Notes": [ 692 "The severity is set by the creator.", 693 "Check SBE Dump associated to this error to debug the failure." 694 ] 695 } 696 }, 697 698 { 699 "Name": "org.open_power.Attn.Error.Terminate", 700 "Subsystem": "cec_hardware", 701 "Severity": "non_error", 702 703 "SRC": 704 { 705 "ReasonCode": "0xD138", 706 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 707 "Words6To9": 708 { 709 } 710 }, 711 712 "Documentation": 713 { 714 "Description": "Status shows TI special attention active", 715 "Message": "TI special attention detected", 716 "Notes": [ 717 "This entry is for any TI special attention event ", 718 "reported by the attention handler component" 719 ] 720 } 721 }, 722 723 { 724 "Name": "org.open_power.Attn.Error.Fail", 725 "Subsystem": "bmc_firmware", 726 "Severity": "unrecoverable_loss_of_function", 727 728 "SRC": 729 { 730 "ReasonCode": "0xD13E", 731 "Words6To9": 732 { 733 "6": 734 { 735 "Description": "Error code from attention handler", 736 "AdditionalDataPropSource": "ERROR_CODE" 737 } 738 } 739 }, 740 "Documentation": 741 { 742 "Description": "The attention handler encountered an error", 743 "MessageArgSources" : ["SRCWord6"], 744 "Message": "Attention handler error %1", 745 "Notes": [ 746 "Attention handler will provide error code" 747 ] 748 } 749 }, 750 751 { 752 "Name": "org.open_power.Attn.Error.Vital", 753 "Subsystem": "processor_chip", 754 "Severity": "critical", 755 756 "SRC": 757 { 758 "ReasonCode": "0xD16D", 759 "Words6To9": 760 { 761 } 762 }, 763 764 "Documentation": 765 { 766 "Description": "Status shows SBE vital attention active", 767 "Message": "SBE vital attention detected", 768 "Notes": [ 769 "This entry is for any SBE vital attention event ", 770 "reported by the attention handler component" 771 ] 772 } 773 }, 774 775 { 776 "Name": "org.open_power.HwDiags.Error.Checkstop", 777 "Subsystem": "cec_hardware", 778 "ActionFlags": [ "service_action", "report", "call_home" ], 779 780 "SRC": 781 { 782 "ReasonCode": "0xE510", 783 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 784 "Words6To9": 785 { 786 "6": 787 { 788 "AdditionalDataPropSource": "SRC6" 789 }, 790 "7": 791 { 792 "AdditionalDataPropSource": "SRC7" 793 }, 794 "8": 795 { 796 "AdditionalDataPropSource": "SRC8" 797 } 798 } 799 }, 800 801 "Documentation": 802 { 803 "Description": "A system checkstop attention has occurred", 804 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 805 "Message": "Error Signature: %1 %2 %3" 806 } 807 }, 808 809 { 810 "Name": "org.open_power.HwDiags.Error.Predictive", 811 "Subsystem": "cec_hardware", 812 "ActionFlags": [ "service_action", "report", "call_home" ], 813 814 "SRC": 815 { 816 "ReasonCode": "0xE511", 817 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 818 "Words6To9": 819 { 820 "6": 821 { 822 "AdditionalDataPropSource": "SRC6" 823 }, 824 "7": 825 { 826 "AdditionalDataPropSource": "SRC7" 827 }, 828 "8": 829 { 830 "AdditionalDataPropSource": "SRC8" 831 } 832 } 833 }, 834 835 "Documentation": 836 { 837 "Description": "A hardware attention requiring service has occurred", 838 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 839 "Message": "Error Signature: %1 %2 %3" 840 } 841 }, 842 843 { 844 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 845 "Subsystem": "power_supply", 846 "Severity": "unrecoverable_redundancy_loss", 847 "ActionFlags": ["service_action", "report"], 848 "ComponentID": "0x2700", 849 850 "SRC": { 851 "Type": "11", 852 "ReasonCode": "0x15F0", 853 "Words6To9": {} 854 }, 855 856 "Callouts": [ 857 { 858 "CalloutList": [ 859 { "Priority": "high", "SymbolicFRU": "pwrsply" } 860 ] 861 } 862 ], 863 864 "Documentation": { 865 "Description": "Power Supply input power fault", 866 "Message": "A power supply has indicated an input or under voltage condition.", 867 "Notes": [ 868 "Check the power supply cabling and/or input power ", 869 "source. The PWRSPLY procedure is used rather than ", 870 "calling out a location code, as typically these faults ", 871 "are related to the supplied power, the cable, or the ", 872 "cable connectors. If the input fault resolves down to an ", 873 "issue with the power supply itself, the power supply ", 874 "indicating this input fault should be called out. Add the ", 875 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 876 "CALLOUT_PRIORITY to something other than high." 877 ] 878 } 879 }, 880 881 { 882 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 883 "Subsystem": "power_supply", 884 "Severity": "unrecoverable_redundancy_loss", 885 "ActionFlags": ["service_action", "report", "call_home"], 886 "ComponentID": "0x2700", 887 888 "SRC": { 889 "Type": "11", 890 "ReasonCode": "0x15F1", 891 "Words6To9": {} 892 }, 893 894 "Documentation": { 895 "Description": "Power Supply power fault", 896 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 897 "Notes": [ 898 "The power supply reporting the fault should be called ", 899 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 900 "specific fault, STATUS_* details, and code level in the ", 901 "AdditionalData section." 902 ] 903 } 904 }, 905 906 { 907 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 908 "Subsystem": "power_supply", 909 "Severity": "unrecoverable", 910 "ActionFlags": ["service_action", "report", "call_home"], 911 "ComponentID": "0x2700", 912 913 "SRC": { 914 "Type": "11", 915 "ReasonCode": "0x15F2", 916 "Words6To9": {} 917 }, 918 919 "Documentation": { 920 "Description": "Power Supply non-power fault", 921 "Message": "A communication failure occurred talking to the power supply", 922 "Notes": [ 923 "Communication problems with the power supply could be ", 924 "the power supply, or any hardware between it and the ", 925 "BMC. Reporting the error should be passing in a call ", 926 "out using CALLOUT_DEVICE_PATH." 927 ] 928 } 929 }, 930 931 { 932 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 933 "Subsystem": "power_supply", 934 "Severity": "unrecoverable_redundancy_loss", 935 "ActionFlags": ["service_action", "report", "call_home"], 936 "ComponentID": "0x2700", 937 938 "SRC": { 939 "Type": "11", 940 "ReasonCode": "0x15F6", 941 "Words6To9": {} 942 }, 943 944 "Callouts": [ 945 { 946 "CalloutList": [ 947 { 948 "Priority": "high", 949 "SymbolicFRUTrusted": "pwrsply", 950 "UseInventoryLocCode": true 951 } 952 ] 953 } 954 ], 955 956 "Documentation": { 957 "Description": "Power Supply is missing", 958 "Message": "A power supply that should be present is missing", 959 "Notes": [ 960 "The CalloutList should use the PWRSPLY symbolic FRU ", 961 "with the trusted location code property. The ", 962 "location code in this callout is obtained from ", 963 "the passed in CALLOUT_INVENTORY_PATH value." 964 ] 965 } 966 }, 967 968 { 969 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 970 "Subsystem": "power_supply", 971 "Severity": "unrecoverable", 972 "ActionFlags": ["service_action", "report", "call_home"], 973 "ComponentID": "0x2700", 974 975 "SRC": { 976 "Type": "11", 977 "ReasonCode": "0x15F7", 978 "Words6To9": {} 979 }, 980 981 "Documentation": { 982 "Description": "Power Supply configuration is not supported", 983 "Message": "The power supply configuration is not supported", 984 "Notes": [ 985 "The combination of power supplies detected in the ", 986 "system is not supported. This could be caused by ", 987 "mismatched models, less than expected number of power ", 988 "supplies, or other unsupported characteristics." 989 ] 990 } 991 }, 992 993 { 994 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 995 "Subsystem": "power_supply", 996 "Severity": "unrecoverable_redundancy_loss", 997 "ActionFlags": ["service_action", "report", "call_home"], 998 "ComponentID": "0x2700", 999 1000 "SRC": { 1001 "Type": "11", 1002 "ReasonCode": "0x1B01", 1003 "Words6To9": {} 1004 }, 1005 1006 "Callouts": [ 1007 { 1008 "CalloutList": [ 1009 { "Priority": "high", "Procedure": "power_overcurrent" } 1010 ] 1011 } 1012 ], 1013 1014 "Documentation": { 1015 "Description": "Power Supply output over-current power fault", 1016 "Message": "A power supply has indicated an output over-current condition." 1017 } 1018 }, 1019 1020 { 1021 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1022 "Subsystem": "power", 1023 "ActionFlags": [ "report", "service_action" ], 1024 "Severity": "unrecoverable", 1025 "ComponentID": "0x2700", 1026 1027 "SRC": 1028 { 1029 "Type": "11", 1030 "ReasonCode": "0x00AC", 1031 "Words6To9": {}, 1032 "PowerFault": true 1033 }, 1034 1035 "Callouts": [ 1036 { 1037 "CalloutList": [ 1038 { "Priority": "high", "SymbolicFRU": "ac_module"} 1039 ] 1040 } 1041 ], 1042 1043 "Documentation": { 1044 "Description": "Input power was lost while the system was powered on.", 1045 "Message": "Input power was lost while the system was powered on.", 1046 "Notes": [ 1047 "Input power was lost while system powered on.", 1048 "The CalloutList should use the ACMODUL symbolic FRU." 1049 ] 1050 } 1051 }, 1052 1053 { 1054 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1055 "Subsystem": "power_sequencer", 1056 "ComponentID": "0x2700", 1057 1058 "SRC": { 1059 "Type": "11", 1060 "ReasonCode": "0x2600", 1061 "Words6To9": {} 1062 }, 1063 1064 "Callouts": [ 1065 { 1066 "CalloutList": [ 1067 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1068 ] 1069 } 1070 ], 1071 1072 "Documentation": { 1073 "Description": "A power off was issued because a power fault was detected", 1074 "Message": "A power off was issued because a power fault was detected", 1075 "Notes": [ 1076 ] 1077 } 1078 }, 1079 1080 { 1081 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1082 "Subsystem": "power_control_hw", 1083 "ComponentID": "0x2700", 1084 1085 "SRC": { 1086 "Type": "11", 1087 "ReasonCode": "0x2602", 1088 "Words6To9": {}, 1089 "PowerFault": true 1090 }, 1091 1092 "Callouts": [ 1093 { 1094 "System": "ibm,rainier", 1095 "CalloutList": [ 1096 { 1097 "Priority": "high", 1098 "LocCode": "P0-C5" 1099 }, 1100 { 1101 "Priority": "medium", 1102 "LocCode": "P0" 1103 } 1104 ] 1105 }, 1106 { 1107 "System": "ibm,everest", 1108 "CalloutList": [ 1109 { 1110 "Priority": "high", 1111 "LocCode": "P0-C59" 1112 }, 1113 { 1114 "Priority": "medium", 1115 "LocCode": "P0" 1116 } 1117 ] 1118 } 1119 ], 1120 1121 "Documentation": { 1122 "Description": "A power off was issued because a regulator for standby power faulted", 1123 "Message": "A power off was issued because a regulator for standby power faulted", 1124 "Notes": [ 1125 ] 1126 } 1127 }, 1128 1129 { 1130 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1131 "Subsystem": "power_sequencer", 1132 "ComponentID": "0x2700", 1133 1134 "SRC": { 1135 "Type": "11", 1136 "ReasonCode": "0x2610", 1137 "Words6To9": {} 1138 }, 1139 1140 "CalloutsUsingAD": { 1141 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1142 { 1143 "ADValue": "PCIE_SLOT0", "Callouts": [ 1144 { 1145 "CalloutList": [ 1146 { "Priority": "high", "LocCode": "P0-C0" }, 1147 { "Priority": "medium", "LocCode": "P0" } 1148 ] 1149 } 1150 ] 1151 }, 1152 { 1153 "ADValue": "PCIE_SLOT1", "Callouts": [ 1154 { 1155 "CalloutList": [ 1156 { "Priority": "high", "LocCode": "P0-C1" }, 1157 { "Priority": "medium", "LocCode": "P0" } 1158 ] 1159 } 1160 ] 1161 }, 1162 { 1163 "ADValue": "PCIE_SLOT2", "Callouts": [ 1164 { 1165 "CalloutList": [ 1166 { "Priority": "high", "LocCode": "P0-C2" }, 1167 { "Priority": "medium", "LocCode": "P0" } 1168 ] 1169 } 1170 ] 1171 }, 1172 { 1173 "ADValue": "PCIE_SLOT3", "Callouts": [ 1174 { 1175 "CalloutList": [ 1176 { "Priority": "high", "LocCode": "P0-C3" }, 1177 { "Priority": "medium", "LocCode": "P0" } 1178 ] 1179 } 1180 ] 1181 }, 1182 { 1183 "ADValue": "PCIE_SLOT4", "Callouts": [ 1184 { 1185 "CalloutList": [ 1186 { "Priority": "high", "LocCode": "P0-C4" }, 1187 { "Priority": "medium", "LocCode": "P0" } 1188 ] 1189 } 1190 ] 1191 }, 1192 { 1193 "ADValue": "PCIE_SLOT7", "Callouts": [ 1194 { 1195 "CalloutList": [ 1196 { "Priority": "high", "LocCode": "P0-C7" }, 1197 { "Priority": "medium", "LocCode": "P0" } 1198 ] 1199 } 1200 ] 1201 }, 1202 { 1203 "ADValue": "PCIE_SLOT8", "Callouts": [ 1204 { 1205 "CalloutList": [ 1206 { "Priority": "high", "LocCode": "P0-C8" }, 1207 { "Priority": "medium", "LocCode": "P0" } 1208 ] 1209 } 1210 ] 1211 }, 1212 { 1213 "ADValue": "PCIE_SLOT9", "Callouts": [ 1214 { 1215 "CalloutList": [ 1216 { "Priority": "high", "LocCode": "P0-C9" }, 1217 { "Priority": "medium", "LocCode": "P0" } 1218 ] 1219 } 1220 ] 1221 }, 1222 { 1223 "ADValue": "PCIE_SLOT10", "Callouts": [ 1224 { 1225 "CalloutList": [ 1226 { "Priority": "high", "LocCode": "P0-C10" }, 1227 { "Priority": "medium", "LocCode": "P0" } 1228 ] 1229 } 1230 ] 1231 }, 1232 { 1233 "ADValue": "PCIE_SLOT11", "Callouts": [ 1234 { 1235 "CalloutList": [ 1236 { "Priority": "high", "LocCode": "P0-C11" }, 1237 { "Priority": "medium", "LocCode": "P0" } 1238 ] 1239 } 1240 ] 1241 }, 1242 { 1243 "ADValue": "PGOOD_12A", "Callouts": [ 1244 { 1245 "CalloutList": [ 1246 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1247 ] 1248 } 1249 ] 1250 }, 1251 { 1252 "ADValue": "PGOOD_12B", "Callouts": [ 1253 { 1254 "CalloutList": [ 1255 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1256 ] 1257 } 1258 ] 1259 }, 1260 { 1261 "ADValue": "PGOOD_12C", "Callouts": [ 1262 { 1263 "CalloutList": [ 1264 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1265 ] 1266 } 1267 ] 1268 }, 1269 { 1270 "ADValue": "PGOOD_12D", "Callouts": [ 1271 { 1272 "CalloutList": [ 1273 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1274 ] 1275 } 1276 ] 1277 }, 1278 { 1279 "ADValue": "PGOOD_12L", "Callouts": [ 1280 { 1281 "CalloutList": [ 1282 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1283 ] 1284 } 1285 ] 1286 }, 1287 { 1288 "ADValue": "PGOOD_12M", "Callouts": [ 1289 { 1290 "CalloutList": [ 1291 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1292 ] 1293 } 1294 ] 1295 }, 1296 { 1297 "ADValue": "PGOOD_12N", "Callouts": [ 1298 { 1299 "CalloutList": [ 1300 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1301 ] 1302 } 1303 ] 1304 }, 1305 { 1306 "ADValue": "PGOOD_12P", "Callouts": [ 1307 { 1308 "CalloutList": [ 1309 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1310 ] 1311 } 1312 ] 1313 }, 1314 { 1315 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1316 { 1317 "CalloutList": [ 1318 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1319 ] 1320 } 1321 ] 1322 }, 1323 { 1324 "ADValue": "PGOOD_12Q", "Callouts": [ 1325 { 1326 "CalloutList": [ 1327 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1328 ] 1329 } 1330 ] 1331 }, 1332 { 1333 "ADValue": "PGOOD_12R", "Callouts": [ 1334 { 1335 "CalloutList": [ 1336 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1337 ] 1338 } 1339 ] 1340 }, 1341 { 1342 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1343 { 1344 "CalloutList": [ 1345 { "Priority": "high", "LocCode": "P0-C14" }, 1346 { "Priority": "medium", "LocCode": "P0-C15" }, 1347 { "Priority": "low", "LocCode": "P0" } 1348 ] 1349 } 1350 ] 1351 }, 1352 { 1353 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1354 { 1355 "CalloutList": [ 1356 { "Priority": "high", "LocCode": "P0-C23" }, 1357 { "Priority": "medium", "LocCode": "P0-C24" }, 1358 { "Priority": "low", "LocCode": "P0" } 1359 ] 1360 } 1361 ] 1362 }, 1363 { 1364 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1365 { 1366 "CalloutList": [ 1367 { "Priority": "high", "LocCode": "P0-C14" }, 1368 { "Priority": "medium", "LocCode": "P0-C15" }, 1369 { "Priority": "low", "LocCode": "P0" } 1370 ] 1371 } 1372 ] 1373 }, 1374 { 1375 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1376 { 1377 "CalloutList": [ 1378 { "Priority": "high", "LocCode": "P0-C23" }, 1379 { "Priority": "medium", "LocCode": "P0-C24" }, 1380 { "Priority": "low", "LocCode": "P0" } 1381 ] 1382 } 1383 ] 1384 }, 1385 { 1386 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1387 { 1388 "CalloutList": [ 1389 { "Priority": "high", "LocCode": "P0-C14" }, 1390 { "Priority": "medium", "LocCode": "P0-C15" }, 1391 { "Priority": "low", "LocCode": "P0" } 1392 ] 1393 } 1394 ] 1395 }, 1396 { 1397 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1398 { 1399 "CalloutList": [ 1400 { "Priority": "high", "LocCode": "P0-C23" }, 1401 { "Priority": "medium", "LocCode": "P0-C24" }, 1402 { "Priority": "low", "LocCode": "P0" } 1403 ] 1404 } 1405 ] 1406 }, 1407 { 1408 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1409 { 1410 "CalloutList": [ 1411 { "Priority": "high", "LocCode": "P0-C14" }, 1412 { "Priority": "medium", "LocCode": "P0-C15" }, 1413 { "Priority": "low", "LocCode": "P0" } 1414 ] 1415 } 1416 ] 1417 }, 1418 { 1419 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1420 { 1421 "CalloutList": [ 1422 { "Priority": "high", "LocCode": "P0-C23" }, 1423 { "Priority": "medium", "LocCode": "P0-C24" }, 1424 { "Priority": "low", "LocCode": "P0" } 1425 ] 1426 } 1427 ] 1428 } 1429 ] 1430 }, 1431 1432 "Documentation": { 1433 "Description": "The power sequencer chip detected a PGOOD fault", 1434 "Message": "The power sequencer chip detected a PGOOD fault", 1435 "Notes": [ 1436 ] 1437 } 1438 }, 1439 1440 { 1441 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 1442 "Subsystem": "power_sequencer", 1443 "ComponentID": "0x2700", 1444 1445 "SRC": { 1446 "Type": "11", 1447 "ReasonCode": "0x2620", 1448 "Words6To9": {} 1449 }, 1450 1451 "CalloutsUsingAD": { 1452 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 1453 { 1454 "ADValue": "12.0V", "Callouts": [ 1455 { 1456 "CalloutList": [ 1457 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1458 ] 1459 } 1460 ] 1461 }, 1462 { 1463 "ADValue": "5.0V_USB", "Callouts": [ 1464 { 1465 "CalloutList": [ 1466 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1467 { "Priority": "medium", "LocCode": "P0" } 1468 ] 1469 } 1470 ] 1471 }, 1472 { 1473 "ADValue": "5.0V_DASD", "Callouts": [ 1474 { 1475 "CalloutList": [ 1476 { "Priority": "medium", "LocCode": "P1" }, 1477 { "Priority": "medium", "LocCode": "P2" }, 1478 { "Priority": "medium", "LocCode": "P3" }, 1479 { "Priority": "low", "LocCode": "P0" } 1480 ] 1481 } 1482 ] 1483 }, 1484 { 1485 "ADValue": "3.3VA", "Callouts": [ 1486 { 1487 "CalloutList": [ 1488 { "Priority": "high", "LocCode": "P0" } 1489 ] 1490 } 1491 ] 1492 }, 1493 { 1494 "ADValue": "3.3VB", "Callouts": [ 1495 { 1496 "CalloutList": [ 1497 { "Priority": "high", "LocCode": "P0" } 1498 ] 1499 } 1500 ] 1501 }, 1502 { 1503 "ADValue": "1.5V", "Callouts": [ 1504 { 1505 "CalloutList": [ 1506 { "Priority": "high", "LocCode": "P0" } 1507 ] 1508 } 1509 ] 1510 }, 1511 { 1512 "ADValue": "1.1V", "Callouts": [ 1513 { 1514 "CalloutList": [ 1515 { "Priority": "high", "LocCode": "P0" } 1516 ] 1517 } 1518 ] 1519 }, 1520 { 1521 "ADValue": "VDDA_DCM0", "Callouts": [ 1522 { 1523 "CalloutList": [ 1524 { "Priority": "high", "LocCode": "P0-C14" }, 1525 { "Priority": "medium", "LocCode": "P0-C15" }, 1526 { "Priority": "low", "LocCode": "P0" } 1527 ] 1528 } 1529 ] 1530 }, 1531 { 1532 "ADValue": "VDDB_DCM0", "Callouts": [ 1533 { 1534 "CalloutList": [ 1535 { "Priority": "high", "LocCode": "P0-C14" }, 1536 { "Priority": "medium", "LocCode": "P0-C15" }, 1537 { "Priority": "low", "LocCode": "P0" } 1538 ] 1539 } 1540 ] 1541 }, 1542 { 1543 "ADValue": "VDDA_DCM1", "Callouts": [ 1544 { 1545 "CalloutList": [ 1546 { "Priority": "high", "LocCode": "P0-C23" }, 1547 { "Priority": "medium", "LocCode": "P0-C24" }, 1548 { "Priority": "low", "LocCode": "P0" } 1549 ] 1550 } 1551 ] 1552 }, 1553 { 1554 "ADValue": "VDDB_DCM1", "Callouts": [ 1555 { 1556 "CalloutList": [ 1557 { "Priority": "high", "LocCode": "P0-C23" }, 1558 { "Priority": "medium", "LocCode": "P0-C24" }, 1559 { "Priority": "low", "LocCode": "P0" } 1560 ] 1561 } 1562 ] 1563 }, 1564 { 1565 "ADValue": "12.0VCS", "Callouts": [ 1566 { 1567 "CalloutList": [ 1568 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1569 ] 1570 } 1571 ] 1572 }, 1573 { 1574 "ADValue": "3.3VCS", "Callouts": [ 1575 { 1576 "CalloutList": [ 1577 { "Priority": "high", "LocCode": "P0" } 1578 ] 1579 } 1580 ] 1581 }, 1582 { 1583 "ADValue": "1.1V_Current", "Callouts": [ 1584 { 1585 "CalloutList": [ 1586 { "Priority": "high", "LocCode": "P0" } 1587 ] 1588 } 1589 ] 1590 }, 1591 { 1592 "ADValue": "5.0V_USB_Current", "Callouts": [ 1593 { 1594 "CalloutList": [ 1595 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1596 { "Priority": "medium", "LocCode": "P0" } 1597 ] 1598 } 1599 ] 1600 }, 1601 { 1602 "ADValue": "5.0V_DASD_Current", "Callouts": [ 1603 { 1604 "CalloutList": [ 1605 { "Priority": "medium", "LocCode": "P1" }, 1606 { "Priority": "medium", "LocCode": "P2" }, 1607 { "Priority": "medium", "LocCode": "P3" }, 1608 { "Priority": "low", "LocCode": "P0" } 1609 ] 1610 } 1611 ] 1612 }, 1613 { 1614 "ADValue": "12.0VN", "Callouts": [ 1615 { 1616 "CalloutList": [ 1617 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1618 ] 1619 } 1620 ] 1621 }, 1622 { 1623 "ADValue": "12.0VP", "Callouts": [ 1624 { 1625 "CalloutList": [ 1626 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1627 ] 1628 } 1629 ] 1630 }, 1631 { 1632 "ADValue": "12.0VQ", "Callouts": [ 1633 { 1634 "CalloutList": [ 1635 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1636 ] 1637 } 1638 ] 1639 }, 1640 { 1641 "ADValue": "12.0VR", "Callouts": [ 1642 { 1643 "CalloutList": [ 1644 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1645 ] 1646 } 1647 ] 1648 }, 1649 { 1650 "ADValue": "ThermalDiode1", "Callouts": [ 1651 { 1652 "CalloutList": [ 1653 { "Priority": "high", "LocCode": "P0" } 1654 ] 1655 } 1656 ] 1657 }, 1658 { 1659 "ADValue": "ThermalDiode2", "Callouts": [ 1660 { 1661 "CalloutList": [ 1662 { "Priority": "high", "LocCode": "P0" } 1663 ] 1664 } 1665 ] 1666 }, 1667 { 1668 "ADValue": "ThermalDiode3", "Callouts": [ 1669 { 1670 "CalloutList": [ 1671 { "Priority": "high", "LocCode": "P0" } 1672 ] 1673 } 1674 ] 1675 }, 1676 { 1677 "ADValue": "ThermalDiode4", "Callouts": [ 1678 { 1679 "CalloutList": [ 1680 { "Priority": "high", "LocCode": "P0" } 1681 ] 1682 } 1683 ] 1684 } 1685 ] 1686 }, 1687 1688 "Documentation": { 1689 "Description": "The power sequencer chip detected a voltage fault", 1690 "Message": "The power sequencer chip detected a voltage fault", 1691 "Notes": [ 1692 ] 1693 } 1694 }, 1695 1696 { 1697 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 1698 "Subsystem": "power", 1699 "Severity": "predictive_redundancy_loss", 1700 "ComponentID": "0x2700", 1701 1702 "SRC": { 1703 "Type": "11", 1704 "ReasonCode": "0x2700", 1705 "Words6To9": {} 1706 }, 1707 1708 "Documentation": { 1709 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1710 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1711 "Notes": [ 1712 "CALLOUT_INVENTORY_PATH should be specified in the ", 1713 "AdditionalData property of the event log so that ", 1714 "the device is called out but not the communication path." 1715 ] 1716 } 1717 }, 1718 1719 { 1720 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 1721 "Subsystem": "power", 1722 "Severity": "non_error", 1723 "MfgSeverity": "predictive_redundancy_loss", 1724 "ActionFlags": ["report"], 1725 "MfgActionFlags": ["service_action", "report", "call_home"], 1726 "ComponentID": "0x2700", 1727 1728 "SRC": { 1729 "Type": "11", 1730 "ReasonCode": "0x2701", 1731 "Words6To9": {} 1732 }, 1733 1734 "Documentation": { 1735 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1736 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1737 "Notes": [ 1738 "CALLOUT_INVENTORY_PATH should be specified in the ", 1739 "AdditionalData property of the event log so that ", 1740 "the device is called out but not the communication path." 1741 ] 1742 } 1743 }, 1744 1745 { 1746 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 1747 "Subsystem": "power", 1748 "ComponentID": "0x2700", 1749 1750 "SRC": { 1751 "Type": "11", 1752 "ReasonCode": "0x2900", 1753 "Words6To9": {} 1754 }, 1755 1756 "Documentation": { 1757 "Description": "A write verification error occurred on a device", 1758 "Message": "A write verification error occurred on a device", 1759 "Notes": [ 1760 "This error occurs when a device register is written, ", 1761 "read back, and the two values do not match. This is ", 1762 "also called a read-back error. The device should be ", 1763 "identified using the CALLOUT_DEVICE_PATH or ", 1764 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 1765 "AdditionalData property of the event log. This will ", 1766 "cause the device and the hardware in the communication ", 1767 "path to be called out." 1768 ] 1769 } 1770 }, 1771 1772 { 1773 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 1774 "Subsystem": "power", 1775 "ComponentID": "0x2700", 1776 1777 "SRC": { 1778 "Type": "11", 1779 "ReasonCode": "0xA013", 1780 "Words6To9": {} 1781 }, 1782 1783 "Callouts": [ 1784 { 1785 "CalloutList": [ 1786 { "Priority": "high", "Procedure": "bmc_code" } 1787 ] 1788 } 1789 ], 1790 1791 "Documentation": { 1792 "Description": "A regulators configuration file error occurred", 1793 "Message": "A regulators configuration file error occurred", 1794 "Notes": [ 1795 "The regulators configuration file could not be found, ", 1796 "could not be read, or had invalid contents." 1797 ] 1798 } 1799 }, 1800 1801 { 1802 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 1803 "Subsystem": "power", 1804 "Severity": "critical_system_term", 1805 "ComponentID": "0x2700", 1806 1807 "SRC": { 1808 "Type": "11", 1809 "ReasonCode": "0xA014", 1810 "Words6To9": {}, 1811 "PowerFault": true 1812 }, 1813 1814 "Callouts": [ 1815 { 1816 "CalloutList": [ 1817 { "Priority": "high", "Procedure": "bmc_code" } 1818 ] 1819 } 1820 ], 1821 1822 "Documentation": { 1823 "Description": "A critical regulators configuration file error occurred", 1824 "Message": "A critical regulators configuration file error occurred", 1825 "Notes": [ 1826 "The regulators configuration file could not be found, ", 1827 "could not be read, or had invalid contents. As a result ", 1828 "voltage regulators could not be configured, and the ", 1829 "chassis could not be powered on." 1830 ] 1831 } 1832 }, 1833 1834 { 1835 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 1836 "Subsystem": "power_sequencer", 1837 "ComponentID": "0x2700", 1838 1839 "SRC": { 1840 "Type": "11", 1841 "ReasonCode": "0xD000", 1842 "Words6To9": {} 1843 }, 1844 1845 "Callouts": [ 1846 { 1847 "CalloutList": [ 1848 { "Priority": "high", "LocCode": "P0" } 1849 ] 1850 } 1851 ], 1852 1853 "Documentation": { 1854 "Description": "The power sequencer chip detected a fault", 1855 "Message": "The power sequencer chip detected a fault", 1856 "Notes": [ 1857 ] 1858 } 1859 }, 1860 1861 { 1862 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 1863 "Subsystem": "power_sequencer", 1864 "ComponentID": "0x2700", 1865 "Severity": "critical", 1866 1867 "SRC": { 1868 "Type": "11", 1869 "ReasonCode": "0xD002", 1870 "Words6To9": {} 1871 }, 1872 1873 "Callouts": [ 1874 { 1875 "CalloutList": [ 1876 { "Priority": "high", "LocCode": "P0" } 1877 ] 1878 } 1879 ], 1880 1881 "Documentation": { 1882 "Description": "System power failed to turn on within timeout period", 1883 "Message": "System power failed to turn on within timeout period", 1884 "Notes": [ 1885 ] 1886 } 1887 }, 1888 1889 { 1890 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 1891 "Subsystem": "power_sequencer", 1892 "ComponentID": "0x2700", 1893 "Severity": "critical", 1894 1895 "SRC": { 1896 "Type": "11", 1897 "ReasonCode": "0xD008", 1898 "Words6To9": {} 1899 }, 1900 1901 "Callouts": [ 1902 { 1903 "CalloutList": [ 1904 { "Priority": "high", "LocCode": "P0" } 1905 ] 1906 } 1907 ], 1908 1909 "Documentation": { 1910 "Description": "System power failed to turn off within timeout period", 1911 "Message": "System power failed to turn off within timeout period", 1912 "Notes": [ 1913 ] 1914 } 1915 }, 1916 1917 { 1918 "Name": "xyz.openbmc_project.Power.Error.Internal", 1919 "Subsystem": "power", 1920 "ComponentID": "0x2700", 1921 1922 "SRC": { 1923 "Type": "11", 1924 "ReasonCode": "0xE000", 1925 "Words6To9": {} 1926 }, 1927 1928 "Callouts": [ 1929 { 1930 "CalloutList": [ 1931 { "Priority": "high", "Procedure": "bmc_code" } 1932 ] 1933 } 1934 ], 1935 1936 "Documentation": { 1937 "Description": "An internal firmware error occurred", 1938 "Message": "An internal firmware error occurred", 1939 "Notes": [ 1940 "The error details must be provided in the AdditionalData ", 1941 "property of the event log." 1942 ] 1943 } 1944 }, 1945 1946 { 1947 "Name": "xyz.openbmc_project.Power.Error.I2C", 1948 "Subsystem": "cec_i2c", 1949 "ComponentID": "0x2700", 1950 1951 "SRC": { 1952 "Type": "11", 1953 "ReasonCode": "0xE100", 1954 "Words6To9": {} 1955 }, 1956 1957 "Documentation": { 1958 "Description": "An I2C error occurred communicating with a device", 1959 "Message": "An I2C error occurred communicating with a device", 1960 "Notes": [ 1961 "The device should be identified using the ", 1962 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 1963 "keywords in the AdditionalData property of the event ", 1964 "log. This will cause the device and the hardware in the ", 1965 "communication path to be called out." 1966 ] 1967 } 1968 }, 1969 1970 { 1971 "Name": "xyz.openbmc_project.Power.Error.PMBus", 1972 "Subsystem": "power", 1973 "ComponentID": "0x2700", 1974 1975 "SRC": { 1976 "Type": "11", 1977 "ReasonCode": "0xE200", 1978 "Words6To9": {} 1979 }, 1980 1981 "Documentation": { 1982 "Description": "A PMBus error occurred on a device", 1983 "Message": "A PMBus error occurred on a device", 1984 "Notes": [ 1985 "This error occurs when the I2C communication was ", 1986 "successful, but the PMBus value read is invalid or ", 1987 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 1988 "in the AdditionalData property of the event log so that ", 1989 "the device is called out but not the communication path." 1990 ] 1991 } 1992 }, 1993 1994 { 1995 "Name": "xyz.openbmc_project.Power.Error.DBus", 1996 "Subsystem": "power", 1997 "ComponentID": "0x2700", 1998 1999 "SRC": { 2000 "Type": "11", 2001 "ReasonCode": "0xE300", 2002 "Words6To9": {} 2003 }, 2004 2005 "Callouts": [ 2006 { 2007 "CalloutList": [ 2008 { "Priority": "high", "Procedure": "bmc_code" } 2009 ] 2010 } 2011 ], 2012 2013 "Documentation": { 2014 "Description": "A firmware inter-process communication (D-Bus) error occurred", 2015 "Message": "A firmware inter-process communication (D-Bus) error occurred" 2016 } 2017 }, 2018 2019 { 2020 "Name": "xyz.openbmc_project.Fan.Error.Fault", 2021 "Subsystem": "power_fans", 2022 "ComponentID": "0x2800", 2023 2024 "SRC": { 2025 "Type": "11", 2026 "ReasonCode": "0x76F0", 2027 "Words6To9": {} 2028 }, 2029 2030 "Documentation": { 2031 "Description": "Fan rotor fault", 2032 "Message": "Fan rotor fault", 2033 "Notes": [ 2034 "This error occurs when a fan rotor has been faulted for a ", 2035 "certain amount of time. The callout is the fan which is ", 2036 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 2037 "passed in during creation and will be either informational ", 2038 "or unrecoverable. The action flags use the defaults and ", 2039 "vary based on the severity." 2040 ] 2041 } 2042 }, 2043 2044 { 2045 "Name": "xyz.openbmc_project.Fan.Error.Missing", 2046 "Subsystem": "power_fans", 2047 "ComponentID": "0x2800", 2048 "Severity": "unrecoverable_redundancy_loss", 2049 "ActionFlags": ["service_action", "report", "call_home"], 2050 2051 "SRC": { 2052 "Type": "11", 2053 "ReasonCode": "0x76F1", 2054 "Words6To9": {} 2055 }, 2056 2057 "Callouts": [ 2058 { 2059 "System": "ibm,rainier", 2060 "CalloutList": [ 2061 { 2062 "Priority": "high", 2063 "SymbolicFRUTrusted": "air_mover", 2064 "UseInventoryLocCode": true 2065 }, 2066 { 2067 "Priority": "low", 2068 "LocCode": "P0" 2069 } 2070 ] 2071 }, 2072 { 2073 "System": "ibm,everest", 2074 "CalloutList": [ 2075 { 2076 "Priority": "high", 2077 "SymbolicFRUTrusted": "air_mover", 2078 "UseInventoryLocCode": true 2079 }, 2080 { 2081 "Priority": "low", 2082 "LocCode": "P1" 2083 } 2084 ] 2085 } 2086 ], 2087 2088 "Documentation": { 2089 "Description": "A fan is missing", 2090 "Message": "A fan is missing", 2091 "Notes": [ 2092 "This error occurs when a fan has been missing for a ", 2093 "certain amount of time. The first callout is the ", 2094 "symbolic FRU AIR_MOVR that has the trusted fan location ", 2095 "code, which it gets using the passed in ", 2096 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 2097 "where the controller and GPIO expander are." 2098 ] 2099 } 2100 }, 2101 2102 { 2103 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 2104 "ComponentID": "0x2800", 2105 "Subsystem": "power_fans", 2106 "Severity": "non_error", 2107 "ActionFlags": ["report"], 2108 "MfgSeverity": "predictive", 2109 "MfgActionFlags": ["service_action", "report"], 2110 2111 "SRC": { 2112 "Type": "11", 2113 "ReasonCode": "0x76F2", 2114 "Words6To9": {} 2115 }, 2116 2117 "Callouts": [ 2118 { 2119 "System": "ibm,rainier", 2120 "CalloutList": [ 2121 {"Priority": "medium", "LocCode": "P0"} 2122 ] 2123 }, 2124 { 2125 "System": "ibm,everest", 2126 "CalloutList": [ 2127 {"Priority": "medium", "LocCode": "P1"} 2128 ] 2129 } 2130 ], 2131 2132 "Documentation": { 2133 "Description": "Presence detect methods for the same fan disagree", 2134 "Message": "Presence detect methods for the same fan disagree", 2135 "Notes": [ 2136 "This error occurs when there is more than one way to detect", 2137 "fan presence, and they don't all agree. For example, the", 2138 "GPIO says a fan isn't present, but the tach readings are", 2139 "nonzero. This is informational, unless in manufacturing.", 2140 "The fan FRU is passed in as a high priority callout.", 2141 "The FRU the GPIO source is on is called out medium." 2142 ] 2143 } 2144 }, 2145 2146 { 2147 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 2148 "ComponentID": "0x2800", 2149 "Subsystem": "power_fans", 2150 "Severity": "critical_system_term", 2151 "ActionFlags": ["service_action", "report", "call_home"], 2152 2153 "SRC": { 2154 "Type": "11", 2155 "ReasonCode": "0x76F3", 2156 "Words6To9": {}, 2157 "PowerFault": true 2158 }, 2159 2160 "Callouts": [ 2161 { 2162 "System": "ibm,rainier", 2163 "CalloutList": [ 2164 {"Priority": "high", "LocCode": "P0-C5"}, 2165 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 2166 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 2167 {"Priority": "low", "LocCode": "P0"} 2168 ] 2169 }, 2170 { 2171 "System": "ibm,everest", 2172 "CalloutList": [ 2173 {"Priority": "high", "LocCode": "P0-C0"}, 2174 {"Priority": "medium", "LocCode": "P1"}, 2175 {"Priority": "low", "LocCode": "P0"} 2176 ] 2177 } 2178 ], 2179 2180 "Documentation": { 2181 "Description": "The fan controller device is offline", 2182 "Message": "The fan controller is offline. The system must be powered off.", 2183 "Notes": [ 2184 "The device that controls the fans is offline so the fan", 2185 "targets and speeds are unknown. The system will be shut", 2186 "down to preserve thermal safety. There may be an I2C", 2187 "or power problem with the device." 2188 ] 2189 } 2190 }, 2191 2192 { 2193 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 2194 "Subsystem": "power_fans", 2195 "ComponentID": "0x2800", 2196 "Severity": "unrecoverable_redundancy_loss", 2197 "ActionFlags": ["service_action", "report", "call_home"], 2198 2199 "SRC": { 2200 "Type": "11", 2201 "ReasonCode": "0x76F4", 2202 "Words6To9": {} 2203 }, 2204 2205 "Callouts": [ 2206 { 2207 "System" : "ibm,rainier", 2208 "CalloutList": [ 2209 {"Priority": "high", "LocCode": "P0-C5"}, 2210 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 2211 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 2212 {"Priority": "low", "LocCode": "P0"} 2213 ] 2214 }, 2215 { 2216 "System" : "ibm,everest", 2217 "CalloutList": [ 2218 {"Priority": "high", "LocCode": "P0-C0"}, 2219 {"Priority": "medium", "LocCode": "P1"}, 2220 {"Priority": "low", "LocCode": "P0"} 2221 ] 2222 } 2223 ], 2224 2225 "Documentation": { 2226 "Description": "Fan GPIO sensors not present", 2227 "Message": "Fan GPIO sensors not present", 2228 "Notes": [ 2229 "The device that reports fan presence is not functioning." 2230 ] 2231 } 2232 }, 2233 2234 { 2235 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 2236 "Subsystem": "power", 2237 "ComponentID": "0x2800", 2238 "Severity": "predictive", 2239 "ActionFlags": ["service_action", "report"], 2240 2241 "SRC": { 2242 "ReasonCode": "0x2801", 2243 "Words6To9": {} 2244 }, 2245 2246 "CalloutsUsingAD": { 2247 "ADName": "SENSOR_NAME", 2248 "CalloutsWithTheirADValues": [ 2249 { 2250 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2251 "Callouts": [ 2252 { 2253 "CalloutList": [ 2254 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2255 ] 2256 } 2257 ] 2258 } 2259 ] 2260 }, 2261 2262 "Documentation": { 2263 "Description": "A temperature sensor exceeded its performance loss threshold.", 2264 "Message": "A temperature sensor exceeded its performance loss threshold.", 2265 "Notes": [ 2266 "A temperature sensor crossed its performance loss threshold value", 2267 "If it is the ambient sensor, then a symbolic FRU will be added.", 2268 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2269 "a FRU callout." 2270 ] 2271 } 2272 }, 2273 2274 { 2275 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 2276 "Subsystem": "power", 2277 "ComponentID": "0x2800", 2278 "Severity": "non_error", 2279 "ActionFlags": ["report"], 2280 "EventType": "env_normal", 2281 2282 "SRC": { 2283 "ReasonCode": "0x2802", 2284 "Words6To9": {} 2285 }, 2286 2287 "CalloutsUsingAD": { 2288 "ADName": "SENSOR_NAME", 2289 "CalloutsWithTheirADValues": [ 2290 { 2291 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2292 "Callouts": [ 2293 { 2294 "CalloutList": [ 2295 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2296 ] 2297 } 2298 ] 2299 } 2300 ] 2301 }, 2302 2303 "Documentation": { 2304 "Description": "A temperature sensor is under its performance loss threshold.", 2305 "Message": "A temperature sensor is under its performance loss threshold.", 2306 "Notes": [ 2307 "A temperature sensor crossed under its performance loss threshold value", 2308 "If it is the ambient sensor, then a symbolic FRU will be added." 2309 ] 2310 } 2311 }, 2312 2313 { 2314 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 2315 "Subsystem": "power", 2316 "ComponentID": "0x2800", 2317 "Severity": "predictive", 2318 "ActionFlags": ["service_action", "report"], 2319 2320 "SRC": { 2321 "ReasonCode": "0x2803", 2322 "Words6To9": {} 2323 }, 2324 2325 "CalloutsUsingAD": { 2326 "ADName": "SENSOR_NAME", 2327 "CalloutsWithTheirADValues": [ 2328 { 2329 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2330 "Callouts": [ 2331 { 2332 "CalloutList": [ 2333 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2334 ] 2335 } 2336 ] 2337 } 2338 ] 2339 }, 2340 2341 "Documentation": { 2342 "Description": "A temperature sensor exceeded its warning threshold.", 2343 "Message": "A temperature sensor exceeded its warning threshold.", 2344 "Notes": [ 2345 "A temperature sensor crossed its warning threshold value", 2346 "If it is the ambient sensor, then a symbolic FRU will be added.", 2347 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2348 "a FRU callout." 2349 ] 2350 } 2351 }, 2352 2353 { 2354 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 2355 "Subsystem": "power", 2356 "ComponentID": "0x2800", 2357 "Severity": "non_error", 2358 "ActionFlags": ["report"], 2359 "EventType": "env_normal", 2360 2361 "SRC": { 2362 "ReasonCode": "0x2804", 2363 "Words6To9": {} 2364 }, 2365 2366 "CalloutsUsingAD": { 2367 "ADName": "SENSOR_NAME", 2368 "CalloutsWithTheirADValues": [ 2369 { 2370 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2371 "Callouts": [ 2372 { 2373 "CalloutList": [ 2374 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2375 ] 2376 } 2377 ] 2378 } 2379 ] 2380 }, 2381 2382 "Documentation": { 2383 "Description": "A temperature sensor is under its warning threshold.", 2384 "Message": "A temperature sensor is under its warning threshold.", 2385 "Notes": [ 2386 "A temperature sensor crossed under its warning threshold value", 2387 "If it is the ambient sensor, then a symbolic FRU will be added." 2388 ] 2389 } 2390 }, 2391 2392 { 2393 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 2394 "Subsystem": "power", 2395 "ComponentID": "0x2800", 2396 "Severity": "predictive", 2397 "ActionFlags": ["service_action", "report"], 2398 2399 "SRC": { 2400 "ReasonCode": "0x2805", 2401 "Words6To9": {} 2402 }, 2403 2404 "CalloutsUsingAD": { 2405 "ADName": "SENSOR_NAME", 2406 "CalloutsWithTheirADValues": [ 2407 { 2408 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2409 "Callouts": [ 2410 { 2411 "CalloutList": [ 2412 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2413 ] 2414 } 2415 ] 2416 } 2417 ] 2418 }, 2419 2420 "Documentation": { 2421 "Description": "A temperature sensor exceeded its critical threshold.", 2422 "Message": "A temperature sensor exceeded its critical threshold.", 2423 "Notes": [ 2424 "A temperature sensor crossed its critical threshold value", 2425 "If it is the ambient sensor, then a symbolic FRU will be added.", 2426 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2427 "a FRU callout." 2428 ] 2429 } 2430 }, 2431 2432 { 2433 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 2434 "Subsystem": "power", 2435 "ComponentID": "0x2800", 2436 "Severity": "non_error", 2437 "ActionFlags": ["report"], 2438 "EventType": "env_normal", 2439 2440 "SRC": { 2441 "ReasonCode": "0x2806", 2442 "Words6To9": {} 2443 }, 2444 2445 "CalloutsUsingAD": { 2446 "ADName": "SENSOR_NAME", 2447 "CalloutsWithTheirADValues": [ 2448 { 2449 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2450 "Callouts": [ 2451 { 2452 "CalloutList": [ 2453 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2454 ] 2455 } 2456 ] 2457 } 2458 ] 2459 }, 2460 2461 "Documentation": { 2462 "Description": "A temperature sensor is under its critical threshold.", 2463 "Message": "A temperature sensor is under its critical threshold.", 2464 "Notes": [ 2465 "A temperature sensor crossed under its critical threshold value", 2466 "If it is the ambient sensor, then a symbolic FRU will be added." 2467 ] 2468 } 2469 }, 2470 2471 { 2472 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 2473 "Subsystem": "power", 2474 "ComponentID": "0x2800", 2475 "Severity": "predictive", 2476 "ActionFlags": ["service_action", "report"], 2477 2478 "SRC": { 2479 "ReasonCode": "0x2807", 2480 "Words6To9": {} 2481 }, 2482 2483 "Callouts": [ 2484 { 2485 "CalloutList": [ 2486 { 2487 "Priority": "high", 2488 "SymbolicFRU": "ambient_temp" 2489 } 2490 ] 2491 } 2492 ], 2493 2494 "Documentation": { 2495 "Description": "The ambient temperature passed the EPOW3 limit.", 2496 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 2497 "Notes": [ 2498 "This error occurs when the ambient temperature surpassed", 2499 "the EPOW3 shutdown limit." 2500 ] 2501 } 2502 }, 2503 2504 { 2505 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 2506 "Subsystem": "power", 2507 "ComponentID": "0x2800", 2508 "Severity": "non_error", 2509 "ActionFlags": ["report"], 2510 "EventType": "env_normal", 2511 2512 "SRC": { 2513 "ReasonCode": "0x2808", 2514 "Words6To9": {} 2515 }, 2516 2517 "Callouts": [ 2518 { 2519 "CalloutList": [ 2520 { 2521 "Priority": "high", 2522 "SymbolicFRU": "ambient_temp_back" 2523 } 2524 ] 2525 } 2526 ], 2527 2528 "Documentation": { 2529 "Description": "The ambient temperature is back under the EPOW3 limit.", 2530 "Message": "The ambient temperature is back under the EPOW3 limit." 2531 } 2532 }, 2533 2534 { 2535 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 2536 "Subsystem": "power", 2537 "ComponentID": "0x2800", 2538 "ActionFlags": ["service_action", "report"], 2539 2540 "SRC": { 2541 "ReasonCode": "0x2809", 2542 "Words6To9": {} 2543 }, 2544 2545 "Callouts": [ 2546 { 2547 "CalloutList": [ 2548 { 2549 "Priority": "high", 2550 "SymbolicFRU": "ambient_temp" 2551 } 2552 ] 2553 } 2554 ], 2555 2556 "Documentation": { 2557 "Description": "The ambient temperature passed the EPOW4 limit.", 2558 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 2559 "Notes": [ 2560 "This error occurs when the ambient temperature surpassed", 2561 "the EPOW4 shutdown limit." 2562 ] 2563 } 2564 }, 2565 2566 { 2567 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 2568 "Subsystem": "ext_env", 2569 "ComponentID": "0x2800", 2570 "Severity": "predictive", 2571 "ActionFlags": ["service_action", "report"], 2572 2573 "SRC": { 2574 "ReasonCode": "0x280A", 2575 "Words6To9": {} 2576 }, 2577 2578 "CalloutsUsingAD": { 2579 "ADName": "SENSOR_NAME", 2580 "CalloutsWithTheirADValues": [ 2581 { 2582 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 2583 "Callouts": [ 2584 { 2585 "CalloutList": [ 2586 { "Priority": "high", "SymbolicFRU": "altitude" } 2587 ] 2588 } 2589 ] 2590 } 2591 ] 2592 }, 2593 2594 "Documentation": { 2595 "Description": "An altitude sensor exceeded its warning threshold.", 2596 "Message": "An altitude sensor exceeded its warning threshold.", 2597 "Notes": [ 2598 "The virtual altitude sensor crossed its warning threshold value", 2599 " and a symbolic FRU will be added." 2600 ] 2601 } 2602 }, 2603 2604 { 2605 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 2606 "Subsystem": "ext_env", 2607 "ComponentID": "0x2800", 2608 "Severity": "non_error", 2609 "ActionFlags": ["report"], 2610 "EventType": "env_normal", 2611 2612 "SRC": { 2613 "ReasonCode": "0x280B", 2614 "Words6To9": {} 2615 }, 2616 2617 "Documentation": { 2618 "Description": "An altitude sensor is under its warning threshold.", 2619 "Message": "An altitude sensor is under its warning threshold.", 2620 "Notes": [ 2621 "The virtual altitude sensor is under its warning threshold value", 2622 " and a symbolic FRU will be added." 2623 ] 2624 } 2625 }, 2626 2627 { 2628 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 2629 "Subsystem": "cec_tod", 2630 "ComponentID": "0x2800", 2631 "Severity": "predictive", 2632 "ActionFlags": ["service_action", "report"], 2633 2634 "SRC": { 2635 "ReasonCode": "0x280C", 2636 "Words6To9": {} 2637 }, 2638 2639 "CalloutsUsingAD": { 2640 "ADName": "SENSOR_NAME", 2641 "CalloutsWithTheirADValues": [ 2642 { 2643 "ADValue": "/xyz/openbmc_project/sensors/voltage/Battery_Voltage", 2644 "Callouts": [ 2645 { 2646 "System": "ibm,rainier", 2647 "CalloutList": [ 2648 { 2649 "Priority": "high", 2650 "LocCode": "P0-E0" 2651 } 2652 ] 2653 }, 2654 { 2655 "System": "ibm,everest", 2656 "CalloutList": [ 2657 { 2658 "Priority": "high", 2659 "LocCode": "P0-C0-E0" 2660 } 2661 ] 2662 } 2663 ] 2664 } 2665 ] 2666 }, 2667 2668 "Documentation": { 2669 "Description": "A voltage sensor went below its critical low threshold.", 2670 "Message": "A voltage sensor went below its critical low threshold." 2671 } 2672 }, 2673 2674 { 2675 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 2676 "Subsystem": "cec_tod", 2677 "ComponentID": "0x2800", 2678 "Severity": "non_error", 2679 "ActionFlags": ["report"], 2680 2681 "SRC": { 2682 "ReasonCode": "0x280D", 2683 "Words6To9": {} 2684 }, 2685 2686 "Documentation": { 2687 "Description": "A voltage sensor is over its critical low threshold.", 2688 "Message": "A voltage sensor is over its critical low threshold." 2689 } 2690 }, 2691 2692 { 2693 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 2694 "Subsystem": "cec_vpd", 2695 "ComponentID": "0x4000", 2696 2697 "SRC": { 2698 "ReasonCode": "0x4000", 2699 "Words6To9": 2700 { 2701 "6": 2702 { 2703 "Description": "Errno of the failure.", 2704 "AdditionalDataPropSource": "CALLOUT_ERRNO" 2705 } 2706 } 2707 }, 2708 2709 "Documentation": { 2710 "Description": "A path access error ocurred", 2711 "Message": "An EEPROM path access error occurred.", 2712 "Notes": [ 2713 "This error occurs when parser is unable to access", 2714 "EEPROM path. Errno and device path are captured as", 2715 "additional data." 2716 ] 2717 } 2718 }, 2719 2720 { 2721 "Name": "com.ibm.VPD.Error.InvalidVPD", 2722 "Subsystem": "cec_vpd", 2723 "ComponentID": "0x4000", 2724 2725 "SRC": { 2726 "ReasonCode": "0x4001", 2727 "Words6To9": 2728 { 2729 } 2730 }, 2731 2732 "Documentation": { 2733 "Description": "Invalid VPD data.", 2734 "Message": "A VPD data exception occurred.", 2735 "Notes": [ 2736 "This error occurs when VPD data is found to be", 2737 "invalid. This can be when VPD file is missing out", 2738 "mandatory records.Inventory path is captured in", 2739 "additional data." 2740 ] 2741 } 2742 }, 2743 2744 { 2745 "Name": "com.ibm.VPD.Error.EccCheckFailed", 2746 "Subsystem": "cec_vpd", 2747 "ComponentID": "0x4000", 2748 2749 "SRC": { 2750 "ReasonCode": "0x4002", 2751 "Words6To9": 2752 { 2753 } 2754 }, 2755 2756 "Documentation": { 2757 "Description": "Invalid VPD ecc data.", 2758 "Message": "A VPD ecc exception occurred.", 2759 "Notes": [ 2760 "This error occurs when VPD ecc check fails for the FRU.", 2761 "Inventory path for the failed FRU is captured in additonal", 2762 "data." 2763 ] 2764 } 2765 }, 2766 2767 { 2768 "Name": "com.ibm.VPD.Error.InvalidJson", 2769 "Subsystem": "cec_vpd", 2770 "ComponentID": "0x4000", 2771 2772 "SRC": { 2773 "ReasonCode": "0x4003", 2774 "Words6To9": 2775 { 2776 } 2777 }, 2778 2779 "Documentation": { 2780 "Description": "Invalid Json", 2781 "Message": "A Json failure occurred.", 2782 "Notes": [ 2783 "This error occurs when parser fails to access", 2784 "Json file or there is any issue with Json data.", 2785 "Failed Json path and cause of failure is captured", 2786 "in additional data." 2787 ] 2788 } 2789 }, 2790 2791 { 2792 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 2793 "Subsystem": "cec_vpd", 2794 "ComponentID": "0x4000", 2795 2796 "SRC": { 2797 "ReasonCode": "0x4004", 2798 "Words6To9": 2799 { 2800 } 2801 }, 2802 2803 "Documentation": { 2804 "Description": "System VPD restore failed", 2805 "Message": "A system VPD restoration error occurred.", 2806 "Notes": [ 2807 "This error occurs when restoring of system VPD fails.", 2808 "The FRU path and reason for failure is captured in", 2809 "additional data." 2810 ] 2811 } 2812 }, 2813 2814 { 2815 "Name": "com.ibm.VPD.Error.DbusFailure", 2816 "Subsystem": "cec_vpd", 2817 "ComponentID": "0x4000", 2818 2819 "SRC": { 2820 "ReasonCode": "0x4005", 2821 "Words6To9": 2822 { 2823 } 2824 }, 2825 2826 "Documentation": { 2827 "Description": "Dbus exception", 2828 "Message": "A Dbus internal error occurred.", 2829 "Notes": [ 2830 "This error occurs when Dbus operation fails.", 2831 "Exceptions details are captured in additonal", 2832 "data." 2833 ] 2834 } 2835 }, 2836 2837 { 2838 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 2839 "Subsystem": "cec_sp_hostboot_iface", 2840 2841 "SRC": 2842 { 2843 "ReasonCode": "0xC101", 2844 "Words6To9": 2845 { 2846 } 2847 }, 2848 2849 "Documentation": 2850 { 2851 "Description": "Host did not respond within the watchdog timeout interval", 2852 "Message": "Host did not respond before the watchdog timeout interval expired", 2853 "Notes": [ 2854 "Host did not respond before the expiry of the watchdog timeout interval.", 2855 "Collecting hostboot dump." 2856 ] 2857 } 2858 } 2859 2860 ] 2861} 2862