1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 "Severity": "non_error", 8 9 "SRC": 10 { 11 "ReasonCode": "0x1001", 12 "Words6To9": 13 { 14 "6": 15 { 16 "Description": "Timeout in ms", 17 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 18 } 19 } 20 }, 21 22 "Documentation": 23 { 24 "Description": "This is a generic timeout error", 25 "Message": "An operation timed out", 26 "Notes": [ 27 "The journal should contain more information" 28 ] 29 } 30 }, 31 32 { 33 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 34 "Subsystem": "bmc_firmware", 35 "Severity": "non_error", 36 37 "SRC": 38 { 39 "ReasonCode": "0x1002", 40 "Words6To9": 41 { 42 } 43 }, 44 45 "Documentation": 46 { 47 "Description": "BMC code had a generic internal failure", 48 "Message": "An application had an internal failure", 49 "Notes": [ 50 "The journal should contain more information" 51 ] 52 } 53 }, 54 55 { 56 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 57 "Subsystem": "user_error", 58 "Severity": "non_error", 59 60 "SRC": 61 { 62 "ReasonCode": "0x1003", 63 "Words6To9": 64 { 65 } 66 }, 67 68 "Documentation": 69 { 70 "Description": "BMC code was given an invalid argument", 71 "Message": "Code was given an invalid argument", 72 "Notes": [ 73 "The journal should contain more information" 74 ] 75 } 76 }, 77 { 78 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 79 "Subsystem": "user_error", 80 "Severity": "non_error", 81 82 "SRC": 83 { 84 "ReasonCode": "0x1004", 85 "Words6To9": 86 { 87 } 88 }, 89 90 "Documentation": 91 { 92 "Description": "An operation failed due to insufficient permission", 93 "Message": "An operation failed due to unsufficient permission", 94 "Notes": [ 95 "The journal should contain more information" 96 ] 97 } 98 }, 99 100 { 101 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 102 "Subsystem": "user_error", 103 "Severity": "non_error", 104 105 "SRC": 106 { 107 "ReasonCode": "0x1005", 108 "Words6To9": 109 { 110 } 111 }, 112 113 "Documentation": 114 { 115 "Description": "An operation failed because it isn't allowed", 116 "Message": "An operation failed because it isn't allowed", 117 "Notes": [ 118 "The journal should contain more information" 119 ] 120 } 121 }, 122 123 { 124 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 125 "Subsystem": "user_error", 126 "Severity": "non_error", 127 128 "SRC": 129 { 130 "ReasonCode": "0x1006", 131 "Words6To9": 132 { 133 } 134 }, 135 136 "Documentation": 137 { 138 "Description": "The server's CA certificate has not been provided", 139 "Message": "The server's CA certificate has not been provided" 140 } 141 }, 142 143 { 144 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 145 "Subsystem": "cec_i2c", 146 147 "SRC": 148 { 149 "ReasonCode": "0x1007", 150 "Words6To9": 151 { 152 "6": 153 { 154 "Description": "errno of the failure", 155 "AdditionalDataPropSource": "CALLOUT_ERRNO" 156 } 157 } 158 }, 159 160 "Documentation": 161 { 162 "Description": "Sensor device read failure", 163 "Message": "There was a failure when reading a sensor device", 164 "Notes": [ 165 "The severity is set by the creator.", 166 "The action flags are set automatically by the code.", 167 "Callouts added based on CALLOUT_DEVICE_PATH." 168 ] 169 } 170 }, 171 172 { 173 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 174 "Subsystem": "cec_i2c", 175 176 "SRC": 177 { 178 "ReasonCode": "0x1008", 179 "Words6To9": 180 { 181 "6": 182 { 183 "Description": "errno of the failure", 184 "AdditionalDataPropSource": "CALLOUT_ERRNO" 185 } 186 } 187 }, 188 189 "Documentation": 190 { 191 "Description": "Device read failure", 192 "Message": "There was a failure when reading a hardware device", 193 "Notes": [ 194 "The severity is set by the creator.", 195 "The action flags are set automatically by the code.", 196 "Callouts added based on CALLOUT_DEVICE_PATH." 197 ] 198 } 199 }, 200 201 { 202 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 203 "Subsystem": "cec_i2c", 204 205 "SRC": 206 { 207 "ReasonCode": "0x1009", 208 "Words6To9": 209 { 210 "6": 211 { 212 "Description": "errno of the failure", 213 "AdditionalDataPropSource": "CALLOUT_ERRNO" 214 } 215 } 216 }, 217 218 "Documentation": 219 { 220 "Description": "Device write failure", 221 "Message": "There was a failure when writing to a hardware device", 222 "Notes": [ 223 "The severity is set by the creator.", 224 "The action flags are set automatically by the code.", 225 "Callouts added based on CALLOUT_DEVICE_PATH" 226 ] 227 } 228 }, 229 230 { 231 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 232 "Subsystem": "cec_i2c", 233 234 "SRC": 235 { 236 "ReasonCode": "0x100A", 237 "Words6To9": 238 { 239 "6": 240 { 241 "Description": "errno of the failure", 242 "AdditionalDataPropSource": "CALLOUT_ERRNO" 243 } 244 } 245 }, 246 247 "Documentation": 248 { 249 "Description": "Device write failure", 250 "Message": "There was a failure when writing to a hardware device", 251 "Notes": [ 252 "The severity is set by the creator.", 253 "The action flags are set automatically by the code.", 254 "Callouts added based on CALLOUT_DEVICE_PATH" 255 ] 256 } 257 }, 258 259 { 260 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 261 "Subsystem": "bmc_firmware", 262 "Severity": "non_error", 263 264 "SRC": 265 { 266 "ReasonCode": "0x2001", 267 "Words6To9": 268 { 269 "6": 270 { 271 "Description": "The bad PEL ID", 272 "AdditionalDataPropSource": "BAD_ID" 273 } 274 } 275 }, 276 277 "Documentation": 278 { 279 "Description": "The BMC sent the host a malformed PEL", 280 "Message": "The BMC sent the host a malformed PEL", 281 "Notes": [ 282 "The host firmware rejected that PEL." 283 ] 284 } 285 }, 286 287 { 288 "Name": "org.open_power.Logging.Error.BadHostPEL", 289 "Subsystem": "platform_firmware", 290 "Severity": "unrecoverable", 291 292 "SRC": 293 { 294 "ReasonCode": "0x2002", 295 "Words6To9": 296 { 297 "6": 298 { 299 "Description": "The PLID of the invalid PEL", 300 "AdditionalDataPropSource": "PLID" 301 }, 302 "7": 303 { 304 "Description": "The corresponding OpenBMC event log ID", 305 "AdditionalDataPropSource": "OBMC_LOG_ID" 306 }, 307 "8": 308 { 309 "Description": "The size of the invalid PEL", 310 "AdditionalDataPropSource": "PEL_SIZE" 311 } 312 } 313 }, 314 315 "Callouts": [ 316 { 317 "CalloutList": [ 318 { "Priority": "high", "Procedure": "bmc_code" } 319 ] 320 } 321 ], 322 323 "Documentation": 324 { 325 "Description": "The host sent the BMC an invalid PEL", 326 "Message": "The host sent the BMC an invalid PEL", 327 "Notes": [ 328 ] 329 } 330 }, 331 332 { 333 "Name": "org.open_power.Logging.Error.TestError1", 334 "Subsystem": "platform_firmware", 335 "Severity": "unrecoverable", 336 337 "SRC": 338 { 339 "ReasonCode": "0x2003", 340 "Words6To9": 341 { 342 } 343 }, 344 345 "Callouts": [ 346 { 347 "CalloutList": [ 348 {"Priority": "high", "Procedure": "bmc_code"}, 349 {"Priority": "medium", "SymbolicFRU": "service_docs"} 350 ] 351 } 352 ], 353 354 "Documentation": 355 { 356 "Description": "An error for testing", 357 "Message": "This is a test error" 358 } 359 }, 360 361 { 362 "Name": "xyz.openbmc_project.Logging.Error.Default", 363 "Subsystem": "other_na", 364 365 "SRC": 366 { 367 "ReasonCode": "0x2004", 368 "Words6To9": 369 { 370 } 371 }, 372 373 "Callouts": [ 374 { 375 "CalloutList": [ 376 { "Priority": "high", "Procedure": "bmc_code" } 377 ] 378 } 379 ], 380 381 "Documentation": 382 { 383 "Description": "This entry is used when no other matching entry is found", 384 "Message": "Unknown (Original event not in message registry)", 385 "Notes": [ 386 "This is used when the actual error name isn't found in ", 387 "the registry. The original error name will be stored ", 388 "in the UserData section that contains the AdditionalData ", 389 "properties using the key ERROR_NAME.", 390 "This error may contain callouts if the creator passed ", 391 "them in.", 392 "The severity is set by the creator.", 393 "If this error is seen, then a code change needs to be ", 394 "made to add the missing error entry to this registry." 395 ] 396 } 397 }, 398 399 { 400 "Name": "org.open_power.Logging.Error.TestError2", 401 "Subsystem": "bmc_firmware", 402 "Severity": "recovered", 403 "ActionFlags": ["report"], 404 405 "SRC": 406 { 407 "ReasonCode": "0x2005", 408 "Words6To9": 409 { 410 } 411 }, 412 413 "Callouts": [ 414 { 415 "CalloutList": [ 416 { "Priority": "high", "LocCode": "P0" } 417 ] 418 } 419 ], 420 421 "Documentation": 422 { 423 "Description": "An error for testing", 424 "Message": "This is a test recoverable error", 425 "Notes": [ 426 "This error is not created by BMC code and is ", 427 "only used for error injection tests." 428 ] 429 } 430 }, 431 432 { 433 "Name": "org.open_power.PHAL.Error.Boot", 434 "Subsystem": "cec_hardware", 435 "ComponentID": "0x3000", 436 "Severity": "unrecoverable", 437 438 "SRC": 439 { 440 "ReasonCode": "0x3001", 441 "Words6To9": 442 { 443 } 444 }, 445 446 "Documentation": 447 { 448 "Description": "Failure occurred during boot process", 449 "Message": "Failure occurred during boot process", 450 "Notes": [ 451 "Debug traces will be captured in AdditionalData section" 452 ] 453 } 454 }, 455 456 { 457 "Name": "org.open_power.PHAL.Error.PrePowerOff", 458 "Subsystem": "cec_hardware", 459 "ComponentID": "0x3000", 460 461 "SRC": 462 { 463 "ReasonCode": "0x3002", 464 "Words6To9": 465 { 466 } 467 }, 468 469 "Documentation": 470 { 471 "Description": "Failure occurred during PHAL pre-poweroff operations", 472 "Message": "Failure occurred during PHAL pre-poweroff operations", 473 "Notes": [ 474 "Severity needs to be set based on needs for this registry.", 475 "FFDC (First Failure Data Collection) will be collected ", 476 "and added into PEL." 477 ] 478 } 479 }, 480 481 { 482 "Name": "org.open_power.PHAL.Error.devtreeSync", 483 "Subsystem": "cec_hardware", 484 "ComponentID": "0x3000", 485 "Severity": "unrecoverable", 486 487 "SRC": 488 { 489 "ReasonCode": "0x3003", 490 "Words6To9": 491 { 492 } 493 }, 494 495 "Documentation": 496 { 497 "Description": "Failure occurred during PHAL devtree sync ", 498 "Message": "Failure occurred during PHAL devtree sync", 499 "Notes": [ 500 "The journal should contain more information" 501 ] 502 } 503 }, 504 505 { 506 "Name": "org.open_power.PHAL.Error.devtreeBackup", 507 "Subsystem": "cec_hardware", 508 "ComponentID": "0x3000", 509 "Severity": "unrecoverable", 510 511 "SRC": 512 { 513 "ReasonCode": "0x3004", 514 "Words6To9": 515 { 516 } 517 }, 518 519 "Documentation": 520 { 521 "Description": "Failure occurred during PHAL devtree backup ", 522 "Message": "Failure occurred during PHAL devtree backup", 523 "Notes": [ 524 "The journal should contain more information" 525 ] 526 } 527 }, 528 529 { 530 "Name": "org.open_power.PHAL.Error.HostRunning", 531 "Subsystem": "cec_sp_hostboot_iface", 532 "ComponentID": "0x3000", 533 534 "SRC": 535 { 536 "ReasonCode": "0x3005", 537 "Words6To9": 538 { 539 } 540 }, 541 542 "Documentation": 543 { 544 "Description": "Host did not respond to BMC after a BMC reset", 545 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 546 "Notes": [ 547 "System will be left in its current state to ensure host ", 548 "is not unexpectedly taken down. There is most likely an ", 549 "issue in the software or hardware communication path ", 550 "between the BMC and the Host firmware.", 551 "A BMC dump will be collected with relevant FFDC." 552 ] 553 } 554 }, 555 556 { 557 "Name": "org.open_power.PHAL.Error.devtreeReinit", 558 "Subsystem": "cec_hardware", 559 "ComponentID": "0x3000", 560 "Severity": "unrecoverable", 561 562 "SRC": 563 { 564 "ReasonCode": "0x3006", 565 "Words6To9": 566 { 567 } 568 }, 569 570 "Documentation": 571 { 572 "Description": "Failure re-initializing BMC to Host data structure", 573 "Message": "Failure occurred during re-initializing BMC to Host data structure", 574 "Notes": [ 575 "The journal should contain more information" 576 ] 577 } 578 }, 579 580 { 581 "Name": "org.open_power.HardwareIsolation.Error", 582 "Subsystem": "cec_hardware", 583 "ComponentID": "0x3100", 584 585 "SRC": 586 { 587 "ReasonCode": "0x3101", 588 "Words6To9": 589 { 590 } 591 }, 592 593 "Documentation": 594 { 595 "Description": "Failure occurred during hardware isolation operations", 596 "Message": "Failure occurred during hardware isolation operations", 597 "Notes": [ 598 "Severity needs to be set based on needs for this registry.", 599 "Debug traces will be captured in AdditionalData section" 600 ] 601 } 602 }, 603 604 { 605 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 606 "Subsystem": "cec_sp_hostboot_iface", 607 "ComponentID": "0x3400", 608 "SRC": 609 { 610 "ReasonCode": "0x3401", 611 "Words6To9": 612 { 613 } 614 }, 615 "Documentation": 616 { 617 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 618 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 619 "Notes": [ 620 "System will follow recovery policy, resulting in this ", 621 "error and most likely a a reboot of the host. The issue ", 622 "is most likely the result of the BMC rebooting while the ", 623 "host was booting and in a state where it still needed ", 624 "the BMC to complete its boot." 625 ] 626 } 627 }, 628 629 { 630 "Name": "xyz.openbmc_project.State.ChassisPowerBad", 631 "Subsystem": "input_power_source", 632 "ComponentID": "0x3400", 633 "SRC": 634 { 635 "ReasonCode": "0x3402", 636 "Words6To9": 637 { 638 } 639 }, 640 "Callouts": [ 641 { 642 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 643 } 644 ], 645 "Documentation": 646 { 647 "Description": "Chassis input power is in a bad state", 648 "Message": "Chassis input power is in a bad state, look for other logs with more details", 649 "Notes": [ 650 "The system is most likely in a limited power situation. ", 651 "There is enough power for the BMC to operate but not the ", 652 "CEC hardware. Check for UPS or brownout logs." 653 ] 654 } 655 }, 656 657 { 658 "Name": "xyz.openbmc_project.State.PinholeReset", 659 "Subsystem": "cec_op_panel", 660 "ComponentID": "0x3400", 661 "SRC": 662 { 663 "ReasonCode": "0x3403", 664 "Words6To9": 665 { 666 } 667 }, 668 "Documentation": 669 { 670 "Description": "User initiated a pinhole reset via the op-panel", 671 "Message": "User initiated a pinhole reset via the op-panel", 672 "Notes": [ 673 "This is a notification log to record the fact that a ", 674 "pinhole reset was performed on the BMC, resulting in a ", 675 "hard reset of the BMC." 676 ] 677 } 678 }, 679 680 { 681 "Name": "xyz.openbmc_project.State.Error.CriticalServiceFailure", 682 "Subsystem": "bmc_firmware", 683 "ComponentID": "0x3400", 684 "SRC": 685 { 686 "ReasonCode": "0x3404", 687 "Words6To9": 688 { 689 } 690 }, 691 "Callouts": [ 692 { 693 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 694 } 695 ], 696 "Documentation": 697 { 698 "Description": "A critical BMC application has failed on the system", 699 "Message": "A critical BMC application has failed on the system, the BMC is in an undefined state", 700 "Notes": [ 701 "As a part of generating this error log, a BMC dump has ", 702 "also been generated. Please collect this dump if possible. ", 703 "The BMC state is undefined but basic services could still ", 704 "be available. Usually an AC cycle of the entire system is ", 705 "the best recovery option from this error." 706 ] 707 } 708 }, 709 710 { 711 "Name": "xyz.openbmc_project.State.Error.SecurityCheckFail", 712 "Subsystem": "bmc_firmware", 713 "ComponentID": "0x3400", 714 "SRC": 715 { 716 "ReasonCode": "0x3405", 717 "Words6To9": 718 { 719 } 720 }, 721 "Callouts": [ 722 { 723 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 724 } 725 ], 726 "Documentation": 727 { 728 "Description": "A firmware security check has failed", 729 "Message": "A firmware security check has failed, most likely something is not configured correctly", 730 "Notes": [ 731 "This log is only generated in the manufacturing ", 732 "environment and it indicates that something has not ", 733 "been configured correctly. Use the data in the PEL to ", 734 "determine what that is." 735 ] 736 } 737 }, 738 739 { 740 "Name": "xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure", 741 "Subsystem": "bmc_firmware", 742 "ComponentID": "0x3400", 743 "SRC": 744 { 745 "ReasonCode": "0x3406", 746 "Words6To9": 747 { 748 } 749 }, 750 "Callouts": [ 751 { 752 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 753 } 754 ], 755 "Documentation": 756 { 757 "Description": "The system has failed to reach BMC Ready state", 758 "Message": "The system has failed to reach BMC Ready state, look for other errors", 759 "Notes": [ 760 "This log indicates a critical BMC application required ", 761 "for the BMC to reach Ready state has failed to start ", 762 "successfully. Look in the log for other errors indicating ", 763 "what has failed." 764 ] 765 } 766 }, 767 768 { 769 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOnFailure", 770 "Subsystem": "bmc_firmware", 771 "ComponentID": "0x3400", 772 "SRC": 773 { 774 "ReasonCode": "0x3407", 775 "Words6To9": 776 { 777 } 778 }, 779 "Callouts": [ 780 { 781 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 782 } 783 ], 784 "Documentation": 785 { 786 "Description": "The system has failed to reach chassis power on state", 787 "Message": "The system has failed to reach chassis power on state, look for other errors", 788 "Notes": [ 789 "This log indicates a critical BMC application required ", 790 "for the BMC to power on the chassis has failed to start ", 791 "successfully. Look in the log for other errors indicating ", 792 "what has failed." 793 ] 794 } 795 }, 796 797 { 798 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOffFailure", 799 "Subsystem": "bmc_firmware", 800 "ComponentID": "0x3400", 801 "SRC": 802 { 803 "ReasonCode": "0x3408", 804 "Words6To9": 805 { 806 } 807 }, 808 "Callouts": [ 809 { 810 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 811 } 812 ], 813 "Documentation": 814 { 815 "Description": "The system has failed to reach chassis power off state", 816 "Message": "The system has failed to reach chassis power off state, look for other errors", 817 "Notes": [ 818 "This log indicates a critical BMC application required ", 819 "for the BMC to power off the chassis has failed to start ", 820 "successfully. Look in the log for other errors indicating ", 821 "what has failed." 822 ] 823 } 824 }, 825 826 { 827 "Name": "xyz.openbmc_project.State.Host.Error.HostStartFailure", 828 "Subsystem": "bmc_firmware", 829 "ComponentID": "0x3400", 830 "SRC": 831 { 832 "ReasonCode": "0x3409", 833 "Words6To9": 834 { 835 } 836 }, 837 "Callouts": [ 838 { 839 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 840 } 841 ], 842 "Documentation": 843 { 844 "Description": "The system has failed to start the host firmware", 845 "Message": "The system has failed to start the host firmware, look for other errors", 846 "Notes": [ 847 "This log indicates a critical BMC application required ", 848 "for the BMC to start the host has failed to start ", 849 "successfully. Look in the log for other errors indicating ", 850 "what has failed." 851 ] 852 } 853 }, 854 855 { 856 "Name": "xyz.openbmc_project.State.Host.Error.HostStartMinFailure", 857 "Subsystem": "bmc_firmware", 858 "ComponentID": "0x3400", 859 "SRC": 860 { 861 "ReasonCode": "0x3410", 862 "Words6To9": 863 { 864 } 865 }, 866 "Callouts": [ 867 { 868 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 869 } 870 ], 871 "Documentation": 872 { 873 "Description": "The system has failed to start the host firmware", 874 "Message": "The system has failed to start the host firmware, look for other errors", 875 "Notes": [ 876 "This log indicates a critical BMC application required ", 877 "for the BMC to start the host has failed to start ", 878 "successfully. Look in the log for other errors indicating ", 879 "what has failed." 880 ] 881 } 882 }, 883 884 { 885 "Name": "xyz.openbmc_project.State.Host.Error.HostShutdownFailure", 886 "Subsystem": "bmc_firmware", 887 "ComponentID": "0x3400", 888 "SRC": 889 { 890 "ReasonCode": "0x3411", 891 "Words6To9": 892 { 893 } 894 }, 895 "Callouts": [ 896 { 897 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 898 } 899 ], 900 "Documentation": 901 { 902 "Description": "The system has failed to shutdown the host firmware", 903 "Message": "The system has failed to shutdown the host firmware, look for other errors", 904 "Notes": [ 905 "This log indicates a critical BMC application required ", 906 "to shutdown the host firmware has failed to start ", 907 "successfully. Look in the log for other errors indicating ", 908 "what has failed." 909 ] 910 } 911 }, 912 913 { 914 "Name": "xyz.openbmc_project.State.Host.Error.HostStopFailure", 915 "Subsystem": "bmc_firmware", 916 "ComponentID": "0x3400", 917 "SRC": 918 { 919 "ReasonCode": "0x3412", 920 "Words6To9": 921 { 922 } 923 }, 924 "Callouts": [ 925 { 926 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 927 } 928 ], 929 "Documentation": 930 { 931 "Description": "The system has failed to stop the host firmware", 932 "Message": "The system has failed to stop the host firmware, look for other errors", 933 "Notes": [ 934 "This log indicates a critical BMC application required ", 935 "to stop the host firmware has failed to start ", 936 "successfully. Look in the log for other errors indicating ", 937 "what has failed." 938 ] 939 } 940 }, 941 942 { 943 "Name": "xyz.openbmc_project.State.Host.Error.HostRebootFailure", 944 "Subsystem": "bmc_firmware", 945 "ComponentID": "0x3400", 946 "SRC": 947 { 948 "ReasonCode": "0x3413", 949 "Words6To9": 950 { 951 } 952 }, 953 "Callouts": [ 954 { 955 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 956 } 957 ], 958 "Documentation": 959 { 960 "Description": "The system has failed to reboot the host firmware", 961 "Message": "The system has failed to reboot the host firmware, look for other errors", 962 "Notes": [ 963 "This log indicates a critical BMC application required ", 964 "to reboot the host firmware has failed to start ", 965 "successfully. Look in the log for other errors indicating ", 966 "what has failed." 967 ] 968 } 969 }, 970 971 { 972 "Name": "xyz.openbmc_project.State.Error.HostQuiesce", 973 "Subsystem": "bmc_firmware", 974 "ComponentID": "0x3400", 975 "SRC": 976 { 977 "ReasonCode": "0x3414", 978 "Words6To9": 979 { 980 } 981 }, 982 "Callouts": [ 983 { 984 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 985 } 986 ], 987 "Documentation": 988 { 989 "Description": "The host firmware has failed to boot", 990 "Message": "The host firmware has failed to boot and has entered a Quiesce state. Look for other errors.", 991 "Notes": [ 992 "This log indicates that the host firmware has failed to ", 993 "boot and all retries have been exhausted. There should be ", 994 "other logs with more details on the boot failure reason. " 995 ] 996 } 997 }, 998 999 { 1000 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 1001 "Subsystem": "processor_chip", 1002 "ComponentID": "0x3500", 1003 1004 "SRC": 1005 { 1006 "ReasonCode": "0x3500", 1007 "Words6To9": 1008 { 1009 "6": 1010 { 1011 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1012 "AdditionalDataPropSource": "SRC6" 1013 } 1014 } 1015 }, 1016 1017 "Documentation": 1018 { 1019 "Description": "chipop failure with SBE provided FFDC", 1020 "Message": "chipop request failure reported by SBE", 1021 "Notes": [ 1022 "The severity is set by the creator.", 1023 "Callouts added based on SBE provided FFDC.", 1024 "SBE provided additional debug data included as part of the", 1025 "additional user data section." 1026 ] 1027 } 1028 }, 1029 1030 { 1031 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 1032 "Subsystem": "processor_chip", 1033 "ComponentID": "0x3500", 1034 1035 "SRC": 1036 { 1037 "ReasonCode": "0x3501", 1038 "Words6To9": 1039 { 1040 "6": 1041 { 1042 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1043 "AdditionalDataPropSource": "SRC6" 1044 } 1045 } 1046 }, 1047 1048 "Documentation": 1049 { 1050 "Description": "SBE chipop timeout", 1051 "Message": "chipop timeout reported during SBE communication", 1052 "Notes": [ 1053 "The severity is set by the creator.", 1054 "Check SBE Dump associated to this error to debug the failure." 1055 ] 1056 } 1057 }, 1058 1059 { 1060 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 1061 "Subsystem": "processor_chip", 1062 "ComponentID": "0x3500", 1063 1064 "SRC": 1065 { 1066 "ReasonCode": "0x3502", 1067 "Words6To9": 1068 { 1069 "6": 1070 { 1071 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1072 "AdditionalDataPropSource": "SRC6" 1073 }, 1074 "7": 1075 { 1076 "Description": "Value of SBE state", 1077 "AdditionalDataPropSource": "SRC7" 1078 } 1079 } 1080 }, 1081 1082 "Documentation": 1083 { 1084 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 1085 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 1086 "Notes": [ 1087 "The severity is set by the creator." 1088 ] 1089 } 1090 }, 1091 1092 { 1093 "Name": "org.open_power.Processor.Error.SbeBootFailure", 1094 "Subsystem": "processor_chip", 1095 "ComponentID": "0x3500", 1096 1097 "SRC": 1098 { 1099 "ReasonCode": "0x3503", 1100 "Words6To9": 1101 { 1102 "6": 1103 { 1104 "Description": "[0:15] chip position", 1105 "AdditionalDataPropSource": "SRC6" 1106 } 1107 } 1108 }, 1109 1110 "Documentation": 1111 { 1112 "Description": "Boot failure with SBE provided FFDC", 1113 "Message": "Boot failure reported by SBE", 1114 "Notes": [ 1115 "The severity is set by the creator.", 1116 "Callouts added based on SBE provided FFDC.", 1117 "SBE provided additional debug data included as part of the", 1118 "additional user data section." 1119 ] 1120 } 1121 }, 1122 1123 { 1124 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 1125 "Subsystem": "processor_chip", 1126 "ComponentID": "0x3500", 1127 1128 "SRC": 1129 { 1130 "ReasonCode": "0x3504", 1131 "Words6To9": 1132 { 1133 } 1134 }, 1135 1136 "Documentation": 1137 { 1138 "Description": "SBE Boot timeout", 1139 "Message": "timeout reported during SBE boot process", 1140 "Notes": [ 1141 "The severity is set by the creator.", 1142 "Check SBE Dump associated to this error to debug the failure." 1143 ] 1144 } 1145 }, 1146 1147 { 1148 "Name": "org.open_power.Attn.Error.Terminate", 1149 "Subsystem": "cec_hardware", 1150 "Severity": "non_error", 1151 1152 "SRC": 1153 { 1154 "ReasonCode": "0xD138", 1155 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 1156 "Words6To9": 1157 { 1158 } 1159 }, 1160 1161 "Documentation": 1162 { 1163 "Description": "Status shows TI special attention active", 1164 "Message": "TI special attention detected", 1165 "Notes": [ 1166 "This entry is for any TI special attention event ", 1167 "reported by the attention handler component" 1168 ] 1169 } 1170 }, 1171 1172 { 1173 "Name": "org.open_power.Attn.Error.Fail", 1174 "Subsystem": "bmc_firmware", 1175 "Severity": "unrecoverable_loss_of_function", 1176 1177 "SRC": 1178 { 1179 "ReasonCode": "0xD13E", 1180 "Words6To9": 1181 { 1182 "6": 1183 { 1184 "Description": "Error code from attention handler", 1185 "AdditionalDataPropSource": "ERROR_CODE" 1186 } 1187 } 1188 }, 1189 "Documentation": 1190 { 1191 "Description": "The attention handler encountered an error", 1192 "MessageArgSources" : ["SRCWord6"], 1193 "Message": "Attention handler error %1", 1194 "Notes": [ 1195 "Attention handler will provide error code" 1196 ] 1197 } 1198 }, 1199 1200 { 1201 "Name": "org.open_power.Attn.Error.Vital", 1202 "Subsystem": "processor_chip", 1203 "Severity": "critical", 1204 1205 "SRC": 1206 { 1207 "ReasonCode": "0xD16D", 1208 "Words6To9": 1209 { 1210 } 1211 }, 1212 1213 "Documentation": 1214 { 1215 "Description": "Status shows SBE vital attention active", 1216 "Message": "SBE vital attention detected", 1217 "Notes": [ 1218 "This entry is for any SBE vital attention event ", 1219 "reported by the attention handler component" 1220 ] 1221 } 1222 }, 1223 1224 { 1225 "Name": "org.open_power.HwDiags.Error.Checkstop", 1226 "PossibleSubsystems": [ 1227 "processor", "processor_fru", "processor_unit", "processor_bus", 1228 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1229 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1230 ], 1231 "Severity": "unrecoverable", 1232 "ActionFlags": [ "service_action", "report", "call_home" ], 1233 1234 "SRC": 1235 { 1236 "ReasonCode": "0xE510", 1237 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1238 "Words6To9": 1239 { 1240 "6": 1241 { 1242 "AdditionalDataPropSource": "SRC6" 1243 }, 1244 "7": 1245 { 1246 "AdditionalDataPropSource": "SRC7" 1247 }, 1248 "8": 1249 { 1250 "AdditionalDataPropSource": "SRC8" 1251 } 1252 } 1253 }, 1254 1255 "Documentation": 1256 { 1257 "Description": "A system checkstop attention has occurred", 1258 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1259 "Message": "Error Signature: %1 %2 %3" 1260 } 1261 }, 1262 1263 { 1264 "Name": "org.open_power.HwDiags.Error.Predictive", 1265 "PossibleSubsystems": [ 1266 "processor", "processor_fru", "processor_unit", "processor_bus", 1267 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1268 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1269 ], 1270 "Severity": "predictive", 1271 "ActionFlags": [ "service_action", "report", "call_home" ], 1272 1273 "SRC": 1274 { 1275 "ReasonCode": "0xE511", 1276 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1277 "Words6To9": 1278 { 1279 "6": 1280 { 1281 "AdditionalDataPropSource": "SRC6" 1282 }, 1283 "7": 1284 { 1285 "AdditionalDataPropSource": "SRC7" 1286 }, 1287 "8": 1288 { 1289 "AdditionalDataPropSource": "SRC8" 1290 } 1291 } 1292 }, 1293 1294 "Documentation": 1295 { 1296 "Description": "A hardware attention requiring service has occurred", 1297 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1298 "Message": "Error Signature: %1 %2 %3" 1299 } 1300 }, 1301 1302 { 1303 "Name": "org.open_power.HwDiags.Error.Informational", 1304 "PossibleSubsystems": [ 1305 "processor", "processor_fru", "processor_unit", "processor_bus", 1306 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1307 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1308 ], 1309 "Severity": "non_error", 1310 "ActionFlags": [ "hidden", "dont_report" ], 1311 1312 "SRC": 1313 { 1314 "ReasonCode": "0xE512", 1315 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1316 "Words6To9": 1317 { 1318 "6": 1319 { 1320 "AdditionalDataPropSource": "SRC6" 1321 }, 1322 "7": 1323 { 1324 "AdditionalDataPropSource": "SRC7" 1325 }, 1326 "8": 1327 { 1328 "AdditionalDataPropSource": "SRC8" 1329 } 1330 } 1331 }, 1332 1333 "Documentation": 1334 { 1335 "Description": "Manual analysis was initiated via the command line. FFDC only.", 1336 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1337 "Message": "Error Signature: %1 %2 %3" 1338 } 1339 }, 1340 1341 { 1342 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 1343 "Subsystem": "power_supply", 1344 "ActionFlags": ["service_action", "report"], 1345 "ComponentID": "0x2700", 1346 1347 "SRC": { 1348 "Type": "11", 1349 "ReasonCode": "0x15F0", 1350 "Words6To9": {} 1351 }, 1352 1353 "Callouts": [ 1354 { 1355 "CalloutList": [ 1356 { "Priority": "high", "SymbolicFRU": "pwrsply" } 1357 ] 1358 } 1359 ], 1360 1361 "Documentation": { 1362 "Description": "Power Supply input power fault", 1363 "Message": "A power supply has indicated an input or under voltage condition.", 1364 "Notes": [ 1365 "Check the power supply cabling and/or input power ", 1366 "source. The PWRSPLY procedure is used rather than ", 1367 "calling out a location code, as typically these faults ", 1368 "are related to the supplied power, the cable, or the ", 1369 "cable connectors. If the input fault resolves down to an ", 1370 "issue with the power supply itself, the power supply ", 1371 "indicating this input fault should be called out. Add the ", 1372 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 1373 "CALLOUT_PRIORITY to something other than high." 1374 ] 1375 } 1376 }, 1377 1378 { 1379 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 1380 "Subsystem": "power_supply", 1381 "ActionFlags": ["service_action", "report", "call_home"], 1382 "ComponentID": "0x2700", 1383 1384 "SRC": { 1385 "Type": "11", 1386 "ReasonCode": "0x15F1", 1387 "Words6To9": {} 1388 }, 1389 1390 "Documentation": { 1391 "Description": "Power Supply power fault", 1392 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 1393 "Notes": [ 1394 "The power supply reporting the fault should be called ", 1395 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1396 "specific fault, STATUS_* details, and code level in the ", 1397 "AdditionalData section." 1398 ] 1399 } 1400 }, 1401 1402 { 1403 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 1404 "Subsystem": "power_supply", 1405 "ActionFlags": ["service_action", "report", "call_home"], 1406 "ComponentID": "0x2700", 1407 1408 "SRC": { 1409 "Type": "11", 1410 "ReasonCode": "0x15F2", 1411 "Words6To9": {} 1412 }, 1413 1414 "Documentation": { 1415 "Description": "Power Supply non-power fault", 1416 "Message": "A communication failure occurred talking to the power supply", 1417 "Notes": [ 1418 "Communication problems with the power supply could be ", 1419 "the power supply, or any hardware between it and the ", 1420 "BMC. Reporting the error should be passing in a call ", 1421 "out using CALLOUT_DEVICE_PATH." 1422 ] 1423 } 1424 }, 1425 1426 { 1427 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 1428 "Subsystem": "power_supply", 1429 "ActionFlags": ["service_action", "report", "call_home"], 1430 "ComponentID": "0x2700", 1431 1432 "SRC": { 1433 "Type": "11", 1434 "ReasonCode": "0x15F6", 1435 "Words6To9": {} 1436 }, 1437 1438 "Callouts": [ 1439 { 1440 "CalloutList": [ 1441 { 1442 "Priority": "high", 1443 "SymbolicFRUTrusted": "pwrsply", 1444 "UseInventoryLocCode": true 1445 } 1446 ] 1447 } 1448 ], 1449 1450 "Documentation": { 1451 "Description": "Power Supply is missing", 1452 "Message": "A power supply that should be present is missing", 1453 "Notes": [ 1454 "The CalloutList should use the PWRSPLY symbolic FRU ", 1455 "with the trusted location code property. The ", 1456 "location code in this callout is obtained from ", 1457 "the passed in CALLOUT_INVENTORY_PATH value." 1458 ] 1459 } 1460 }, 1461 1462 { 1463 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 1464 "Subsystem": "power_supply", 1465 "ActionFlags": ["service_action", "report", "call_home"], 1466 "ComponentID": "0x2700", 1467 1468 "SRC": { 1469 "Type": "11", 1470 "ReasonCode": "0x15F7", 1471 "Words6To9": {} 1472 }, 1473 1474 "Documentation": { 1475 "Description": "Power Supply configuration is not supported", 1476 "Message": "The power supply configuration is not supported", 1477 "Notes": [ 1478 "The combination of power supplies detected in the ", 1479 "system is not supported. This could be caused by ", 1480 "mismatched models, less than expected number of power ", 1481 "supplies, or other unsupported characteristics." 1482 ] 1483 } 1484 }, 1485 1486 { 1487 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.FanFault", 1488 "Subsystem": "power_supply", 1489 "ActionFlags": ["service_action", "report", "call_home"], 1490 "ComponentID": "0x2700", 1491 1492 "SRC": { 1493 "Type": "11", 1494 "ReasonCode": "0x15FF", 1495 "Words6To9": {} 1496 }, 1497 1498 "Documentation": { 1499 "Description": "Power Supply fan fault", 1500 "Message": "A power supply indicated a fan fault has occurred", 1501 "Notes": [ 1502 "The power supply reporting the fault should be called ", 1503 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1504 "specific fault, STATUS_* details, and code level in the ", 1505 "AdditionalData section." 1506 ] 1507 } 1508 }, 1509 1510 { 1511 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 1512 "Subsystem": "power_supply", 1513 "ActionFlags": ["service_action", "report", "call_home"], 1514 "ComponentID": "0x2700", 1515 1516 "SRC": { 1517 "Type": "11", 1518 "ReasonCode": "0x1B01", 1519 "Words6To9": {} 1520 }, 1521 1522 "Callouts": [ 1523 { 1524 "CalloutList": [ 1525 { "Priority": "high", "Procedure": "power_overcurrent" } 1526 ] 1527 } 1528 ], 1529 1530 "Documentation": { 1531 "Description": "Power Supply output over-current power fault", 1532 "Message": "A power supply has indicated an output over-current condition." 1533 } 1534 }, 1535 1536 { 1537 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1538 "Subsystem": "power", 1539 "ActionFlags": [ "report", "service_action" ], 1540 "ComponentID": "0x2700", 1541 1542 "SRC": 1543 { 1544 "Type": "11", 1545 "ReasonCode": "0x00AC", 1546 "Words6To9": {} 1547 }, 1548 1549 "Callouts": [ 1550 { 1551 "CalloutList": [ 1552 { "Priority": "high", "SymbolicFRU": "ac_module"} 1553 ] 1554 } 1555 ], 1556 1557 "Documentation": { 1558 "Description": "Input power was lost while the system was powered on.", 1559 "Message": "Input power was lost while the system was powered on.", 1560 "Notes": [ 1561 "Input power was lost while system powered on.", 1562 "The CalloutList should use the ACMODUL symbolic FRU." 1563 ] 1564 } 1565 }, 1566 1567 { 1568 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1569 "Subsystem": "power_supply", 1570 "ActionFlags": ["service_action", "report", "call_home"], 1571 "ComponentID": "0x2700", 1572 1573 "SRC": { 1574 "Type": "11", 1575 "ReasonCode": "0x2500", 1576 "Words6To9": {} 1577 }, 1578 1579 "Callouts": [ 1580 { 1581 "CalloutList": [ 1582 { "Priority": "high", "Procedure": "power_overcurrent" } 1583 ] 1584 } 1585 ], 1586 1587 "Documentation": { 1588 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1589 "Message": "Power supply PSKill_fault", 1590 "Notes": [ 1591 ] 1592 } 1593 }, 1594 1595 { 1596 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1597 "Subsystem": "power_sequencer", 1598 "ComponentID": "0x2700", 1599 1600 "SRC": { 1601 "Type": "11", 1602 "ReasonCode": "0x2600", 1603 "Words6To9": {} 1604 }, 1605 1606 "Callouts": [ 1607 { 1608 "CalloutList": [ 1609 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1610 ] 1611 } 1612 ], 1613 1614 "Documentation": { 1615 "Description": "A power off was issued because a power fault was detected", 1616 "Message": "A power off was issued because a power fault was detected", 1617 "Notes": [ 1618 ] 1619 } 1620 }, 1621 1622 { 1623 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1624 "Subsystem": "power_control_hw", 1625 "Severity": "critical_system_term", 1626 "ComponentID": "0x2700", 1627 1628 "SRC": { 1629 "Type": "11", 1630 "ReasonCode": "0x2602", 1631 "Words6To9": {} 1632 }, 1633 1634 "Callouts": [ 1635 { 1636 "System": "ibm,rainier", 1637 "CalloutList": [ 1638 { 1639 "Priority": "high", 1640 "LocCode": "P0-C5" 1641 }, 1642 { 1643 "Priority": "medium", 1644 "LocCode": "P0" 1645 } 1646 ] 1647 }, 1648 { 1649 "System": "ibm,everest", 1650 "CalloutList": [ 1651 { 1652 "Priority": "high", 1653 "LocCode": "P0-C59" 1654 }, 1655 { 1656 "Priority": "medium", 1657 "LocCode": "P0" 1658 } 1659 ] 1660 } 1661 ], 1662 1663 "Documentation": { 1664 "Description": "A power off was issued because a regulator for standby power faulted", 1665 "Message": "A power off was issued because a regulator for standby power faulted", 1666 "Notes": [ 1667 ] 1668 } 1669 }, 1670 1671 { 1672 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1673 "Subsystem": "power_sequencer", 1674 "ComponentID": "0x2700", 1675 1676 "SRC": { 1677 "Type": "11", 1678 "ReasonCode": "0x2610", 1679 "Words6To9": {} 1680 }, 1681 1682 "CalloutsUsingAD": { 1683 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1684 { 1685 "ADValue": "PCIE_SLOT0", "Callouts": [ 1686 { 1687 "CalloutList": [ 1688 { "Priority": "high", "LocCode": "P0-C0" }, 1689 { "Priority": "medium", "LocCode": "P0" } 1690 ] 1691 } 1692 ] 1693 }, 1694 { 1695 "ADValue": "PCIE_SLOT1", "Callouts": [ 1696 { 1697 "CalloutList": [ 1698 { "Priority": "high", "LocCode": "P0-C1" }, 1699 { "Priority": "medium", "LocCode": "P0" } 1700 ] 1701 } 1702 ] 1703 }, 1704 { 1705 "ADValue": "PCIE_SLOT2", "Callouts": [ 1706 { 1707 "CalloutList": [ 1708 { "Priority": "high", "LocCode": "P0-C2" }, 1709 { "Priority": "medium", "LocCode": "P0" } 1710 ] 1711 } 1712 ] 1713 }, 1714 { 1715 "ADValue": "PCIE_SLOT3", "Callouts": [ 1716 { 1717 "CalloutList": [ 1718 { "Priority": "high", "LocCode": "P0-C3" }, 1719 { "Priority": "medium", "LocCode": "P0" } 1720 ] 1721 } 1722 ] 1723 }, 1724 { 1725 "ADValue": "PCIE_SLOT4", "Callouts": [ 1726 { 1727 "CalloutList": [ 1728 { "Priority": "high", "LocCode": "P0-C4" }, 1729 { "Priority": "medium", "LocCode": "P0" } 1730 ] 1731 } 1732 ] 1733 }, 1734 { 1735 "ADValue": "PCIE_SLOT5", "Callouts": [ 1736 { 1737 "CalloutList": [ 1738 { "Priority": "high", "LocCode": "P0-C5" }, 1739 { "Priority": "medium", "LocCode": "P0" } 1740 ] 1741 } 1742 ] 1743 }, 1744 { 1745 "ADValue": "PCIE_SLOT6", "Callouts": [ 1746 { 1747 "CalloutList": [ 1748 { "Priority": "high", "LocCode": "P0-C6" }, 1749 { "Priority": "medium", "LocCode": "P0" } 1750 ] 1751 } 1752 ] 1753 }, 1754 { 1755 "ADValue": "PCIE_SLOT7", "Callouts": [ 1756 { 1757 "CalloutList": [ 1758 { "Priority": "high", "LocCode": "P0-C7" }, 1759 { "Priority": "medium", "LocCode": "P0" } 1760 ] 1761 } 1762 ] 1763 }, 1764 { 1765 "ADValue": "PCIE_SLOT8", "Callouts": [ 1766 { 1767 "CalloutList": [ 1768 { "Priority": "high", "LocCode": "P0-C8" }, 1769 { "Priority": "medium", "LocCode": "P0" } 1770 ] 1771 } 1772 ] 1773 }, 1774 { 1775 "ADValue": "PCIE_SLOT9", "Callouts": [ 1776 { 1777 "CalloutList": [ 1778 { "Priority": "high", "LocCode": "P0-C9" }, 1779 { "Priority": "medium", "LocCode": "P0" } 1780 ] 1781 } 1782 ] 1783 }, 1784 { 1785 "ADValue": "PCIE_SLOT10", "Callouts": [ 1786 { 1787 "CalloutList": [ 1788 { "Priority": "high", "LocCode": "P0-C10" }, 1789 { "Priority": "medium", "LocCode": "P0" } 1790 ] 1791 } 1792 ] 1793 }, 1794 { 1795 "ADValue": "PCIE_SLOT11", "Callouts": [ 1796 { 1797 "CalloutList": [ 1798 { "Priority": "high", "LocCode": "P0-C11" }, 1799 { "Priority": "medium", "LocCode": "P0" } 1800 ] 1801 } 1802 ] 1803 }, 1804 { 1805 "ADValue": "PGOOD_12A", "Callouts": [ 1806 { 1807 "CalloutList": [ 1808 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1809 ] 1810 } 1811 ] 1812 }, 1813 { 1814 "ADValue": "PGOOD_12B", "Callouts": [ 1815 { 1816 "CalloutList": [ 1817 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1818 ] 1819 } 1820 ] 1821 }, 1822 { 1823 "ADValue": "PGOOD_12C", "Callouts": [ 1824 { 1825 "CalloutList": [ 1826 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1827 ] 1828 } 1829 ] 1830 }, 1831 { 1832 "ADValue": "PGOOD_12D", "Callouts": [ 1833 { 1834 "CalloutList": [ 1835 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1836 ] 1837 } 1838 ] 1839 }, 1840 { 1841 "ADValue": "PGOOD_12L", "Callouts": [ 1842 { 1843 "CalloutList": [ 1844 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1845 ] 1846 } 1847 ] 1848 }, 1849 { 1850 "ADValue": "PGOOD_12M", "Callouts": [ 1851 { 1852 "CalloutList": [ 1853 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1854 ] 1855 } 1856 ] 1857 }, 1858 { 1859 "ADValue": "PGOOD_12N", "Callouts": [ 1860 { 1861 "CalloutList": [ 1862 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1863 ] 1864 } 1865 ] 1866 }, 1867 { 1868 "ADValue": "PGOOD_12P", "Callouts": [ 1869 { 1870 "CalloutList": [ 1871 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1872 ] 1873 } 1874 ] 1875 }, 1876 { 1877 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1878 { 1879 "CalloutList": [ 1880 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1881 ] 1882 } 1883 ] 1884 }, 1885 { 1886 "ADValue": "PGOOD_12Q", "Callouts": [ 1887 { 1888 "CalloutList": [ 1889 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1890 ] 1891 } 1892 ] 1893 }, 1894 { 1895 "ADValue": "PGOOD_12R", "Callouts": [ 1896 { 1897 "CalloutList": [ 1898 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1899 ] 1900 } 1901 ] 1902 }, 1903 { 1904 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1905 { 1906 "CalloutList": [ 1907 { "Priority": "high", "LocCode": "P0-C14" }, 1908 { "Priority": "medium", "LocCode": "P0-C15" }, 1909 { "Priority": "low", "LocCode": "P0" } 1910 ] 1911 } 1912 ] 1913 }, 1914 { 1915 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1916 { 1917 "CalloutList": [ 1918 { "Priority": "high", "LocCode": "P0-C23" }, 1919 { "Priority": "medium", "LocCode": "P0-C24" }, 1920 { "Priority": "low", "LocCode": "P0" } 1921 ] 1922 } 1923 ] 1924 }, 1925 { 1926 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1927 { 1928 "CalloutList": [ 1929 { "Priority": "high", "LocCode": "P0-C14" }, 1930 { "Priority": "medium", "LocCode": "P0-C15" }, 1931 { "Priority": "low", "LocCode": "P0" } 1932 ] 1933 } 1934 ] 1935 }, 1936 { 1937 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1938 { 1939 "CalloutList": [ 1940 { "Priority": "high", "LocCode": "P0-C23" }, 1941 { "Priority": "medium", "LocCode": "P0-C24" }, 1942 { "Priority": "low", "LocCode": "P0" } 1943 ] 1944 } 1945 ] 1946 }, 1947 { 1948 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1949 { 1950 "CalloutList": [ 1951 { "Priority": "high", "LocCode": "P0-C14" }, 1952 { "Priority": "medium", "LocCode": "P0-C15" }, 1953 { "Priority": "low", "LocCode": "P0" } 1954 ] 1955 } 1956 ] 1957 }, 1958 { 1959 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1960 { 1961 "CalloutList": [ 1962 { "Priority": "high", "LocCode": "P0-C23" }, 1963 { "Priority": "medium", "LocCode": "P0-C24" }, 1964 { "Priority": "low", "LocCode": "P0" } 1965 ] 1966 } 1967 ] 1968 }, 1969 { 1970 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1971 { 1972 "CalloutList": [ 1973 { "Priority": "high", "LocCode": "P0-C14" }, 1974 { "Priority": "medium", "LocCode": "P0-C15" }, 1975 { "Priority": "low", "LocCode": "P0" } 1976 ] 1977 } 1978 ] 1979 }, 1980 { 1981 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1982 { 1983 "CalloutList": [ 1984 { "Priority": "high", "LocCode": "P0-C23" }, 1985 { "Priority": "medium", "LocCode": "P0-C24" }, 1986 { "Priority": "low", "LocCode": "P0" } 1987 ] 1988 } 1989 ] 1990 }, 1991 { 1992 "ADValue": "CP0_VPCIE", "Callouts": [ 1993 { 1994 "CalloutList": [ 1995 { "Priority": "high", "LocCode": "P0-C58" }, 1996 { "Priority": "medium", "LocCode": "P0-C60" }, 1997 { "Priority": "low", "LocCode": "P0" } 1998 ] 1999 } 2000 ] 2001 }, 2002 { 2003 "ADValue": "CP1_VPCIE", "Callouts": [ 2004 { 2005 "CalloutList": [ 2006 { "Priority": "high", "LocCode": "P0-C16" }, 2007 { "Priority": "medium", "LocCode": "P0-C13" }, 2008 { "Priority": "low", "LocCode": "P0" } 2009 ] 2010 } 2011 ] 2012 }, 2013 { 2014 "ADValue": "CP2_VPCIE", "Callouts": [ 2015 { 2016 "CalloutList": [ 2017 { "Priority": "high", "LocCode": "P0-C16" }, 2018 { "Priority": "medium", "LocCode": "P0-C20" }, 2019 { "Priority": "low", "LocCode": "P0" } 2020 ] 2021 } 2022 ] 2023 }, 2024 { 2025 "ADValue": "CP3_VPCIE", "Callouts": [ 2026 { 2027 "CalloutList": [ 2028 { "Priority": "high", "LocCode": "P0-C58" }, 2029 { "Priority": "medium", "LocCode": "P0-C56" }, 2030 { "Priority": "low", "LocCode": "P0" } 2031 ] 2032 } 2033 ] 2034 }, 2035 { 2036 "ADValue": "0V_USB_front", "Callouts": [ 2037 { 2038 "CalloutList": [ 2039 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2040 { "Priority": "medium", "LocCode": "P0" } 2041 ] 2042 } 2043 ] 2044 }, 2045 { 2046 "ADValue": "CP0_VDN", "Callouts": [ 2047 { 2048 "CalloutList": [ 2049 { "Priority": "high", "LocCode": "P0-C63" }, 2050 { "Priority": "medium", "LocCode": "P0-C60" }, 2051 { "Priority": "low", "LocCode": "P0" } 2052 ] 2053 } 2054 ] 2055 }, 2056 { 2057 "ADValue": "CP1_VDN", "Callouts": [ 2058 { 2059 "CalloutList": [ 2060 { "Priority": "high", "LocCode": "P0-C12" }, 2061 { "Priority": "medium", "LocCode": "P0-C13" }, 2062 { "Priority": "low", "LocCode": "P0" } 2063 ] 2064 } 2065 ] 2066 }, 2067 { 2068 "ADValue": "CP2_VDN", "Callouts": [ 2069 { 2070 "CalloutList": [ 2071 { "Priority": "high", "LocCode": "P0-C21" }, 2072 { "Priority": "medium", "LocCode": "P0-C20" }, 2073 { "Priority": "low", "LocCode": "P0" } 2074 ] 2075 } 2076 ] 2077 }, 2078 { 2079 "ADValue": "CP3_VDN", "Callouts": [ 2080 { 2081 "CalloutList": [ 2082 { "Priority": "high", "LocCode": "P0-C54" }, 2083 { "Priority": "medium", "LocCode": "P0-C56" }, 2084 { "Priority": "low", "LocCode": "P0" } 2085 ] 2086 } 2087 ] 2088 }, 2089 { 2090 "ADValue": "CP0_VIO", "Callouts": [ 2091 { 2092 "CalloutList": [ 2093 { "Priority": "high", "LocCode": "P0-C63" }, 2094 { "Priority": "medium", "LocCode": "P0-C60" }, 2095 { "Priority": "low", "LocCode": "P0" } 2096 ] 2097 } 2098 ] 2099 }, 2100 { 2101 "ADValue": "CP1_VIO", "Callouts": [ 2102 { 2103 "CalloutList": [ 2104 { "Priority": "high", "LocCode": "P0-C12" }, 2105 { "Priority": "medium", "LocCode": "P0-C13" }, 2106 { "Priority": "low", "LocCode": "P0" } 2107 ] 2108 } 2109 ] 2110 }, 2111 { 2112 "ADValue": "CP2_VIO", "Callouts": [ 2113 { 2114 "CalloutList": [ 2115 { "Priority": "high", "LocCode": "P0-C21" }, 2116 { "Priority": "medium", "LocCode": "P0-C20" }, 2117 { "Priority": "low", "LocCode": "P0" } 2118 ] 2119 } 2120 ] 2121 }, 2122 { 2123 "ADValue": "CP3_VIO", "Callouts": [ 2124 { 2125 "CalloutList": [ 2126 { "Priority": "high", "LocCode": "P0-C54" }, 2127 { "Priority": "medium", "LocCode": "P0-C56" }, 2128 { "Priority": "low", "LocCode": "P0" } 2129 ] 2130 } 2131 ] 2132 }, 2133 { 2134 "ADValue": "PGOOD_PSU1", "Callouts": [ 2135 { 2136 "CalloutList": [ 2137 { "Priority": "high", "LocCode": "E0" } 2138 ] 2139 } 2140 ] 2141 }, 2142 { 2143 "ADValue": "PGOOD_PSU2", "Callouts": [ 2144 { 2145 "CalloutList": [ 2146 { "Priority": "high", "LocCode": "E1" } 2147 ] 2148 } 2149 ] 2150 }, 2151 { 2152 "ADValue": "PGOOD_PSU3", "Callouts": [ 2153 { 2154 "CalloutList": [ 2155 { "Priority": "high", "LocCode": "E2" } 2156 ] 2157 } 2158 ] 2159 }, 2160 { 2161 "ADValue": "PGOOD_PSU4", "Callouts": [ 2162 { 2163 "CalloutList": [ 2164 { "Priority": "high", "LocCode": "E3" } 2165 ] 2166 } 2167 ] 2168 } 2169 ] 2170 }, 2171 2172 "Documentation": { 2173 "Description": "The power sequencer chip detected a PGOOD fault", 2174 "Message": "The power sequencer chip detected a PGOOD fault", 2175 "Notes": [ 2176 ] 2177 } 2178 }, 2179 2180 { 2181 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 2182 "Subsystem": "power_sequencer", 2183 "ComponentID": "0x2700", 2184 2185 "SRC": { 2186 "Type": "11", 2187 "ReasonCode": "0x2620", 2188 "Words6To9": {} 2189 }, 2190 2191 "CalloutsUsingAD": { 2192 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 2193 { 2194 "ADValue": "12.0V", "Callouts": [ 2195 { 2196 "CalloutList": [ 2197 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2198 ] 2199 } 2200 ] 2201 }, 2202 { 2203 "ADValue": "5.0V_USB", "Callouts": [ 2204 { 2205 "CalloutList": [ 2206 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2207 { "Priority": "medium", "LocCode": "P0" } 2208 ] 2209 } 2210 ] 2211 }, 2212 { 2213 "ADValue": "5.0V_DASD", "Callouts": [ 2214 { 2215 "CalloutList": [ 2216 { "Priority": "medium", "LocCode": "P1" }, 2217 { "Priority": "medium", "LocCode": "P2" }, 2218 { "Priority": "medium", "LocCode": "P3" }, 2219 { "Priority": "low", "LocCode": "P0" } 2220 ] 2221 } 2222 ] 2223 }, 2224 { 2225 "ADValue": "3.3VA", "Callouts": [ 2226 { 2227 "CalloutList": [ 2228 { "Priority": "high", "LocCode": "P0" } 2229 ] 2230 } 2231 ] 2232 }, 2233 { 2234 "ADValue": "3.3VB", "Callouts": [ 2235 { 2236 "CalloutList": [ 2237 { "Priority": "high", "LocCode": "P0" } 2238 ] 2239 } 2240 ] 2241 }, 2242 { 2243 "ADValue": "3V3IO", "Callouts": [ 2244 { 2245 "CalloutList": [ 2246 { "Priority": "high", "LocCode": "P0-C17" } 2247 ] 2248 } 2249 ] 2250 }, 2251 { 2252 "ADValue": "1.5V", "Callouts": [ 2253 { 2254 "CalloutList": [ 2255 { "Priority": "high", "LocCode": "P0" } 2256 ] 2257 } 2258 ] 2259 }, 2260 { 2261 "ADValue": "1.1V", "Callouts": [ 2262 { 2263 "CalloutList": [ 2264 { "Priority": "high", "LocCode": "P0" } 2265 ] 2266 } 2267 ] 2268 }, 2269 { 2270 "ADValue": "VDDA_DCM0", "Callouts": [ 2271 { 2272 "CalloutList": [ 2273 { "Priority": "high", "LocCode": "P0-C14" }, 2274 { "Priority": "medium", "LocCode": "P0-C15" }, 2275 { "Priority": "low", "LocCode": "P0" } 2276 ] 2277 } 2278 ] 2279 }, 2280 { 2281 "ADValue": "VDDB_DCM0", "Callouts": [ 2282 { 2283 "CalloutList": [ 2284 { "Priority": "high", "LocCode": "P0-C14" }, 2285 { "Priority": "medium", "LocCode": "P0-C15" }, 2286 { "Priority": "low", "LocCode": "P0" } 2287 ] 2288 } 2289 ] 2290 }, 2291 { 2292 "ADValue": "VDDA_DCM1", "Callouts": [ 2293 { 2294 "CalloutList": [ 2295 { "Priority": "high", "LocCode": "P0-C23" }, 2296 { "Priority": "medium", "LocCode": "P0-C24" }, 2297 { "Priority": "low", "LocCode": "P0" } 2298 ] 2299 } 2300 ] 2301 }, 2302 { 2303 "ADValue": "VDDB_DCM1", "Callouts": [ 2304 { 2305 "CalloutList": [ 2306 { "Priority": "high", "LocCode": "P0-C23" }, 2307 { "Priority": "medium", "LocCode": "P0-C24" }, 2308 { "Priority": "low", "LocCode": "P0" } 2309 ] 2310 } 2311 ] 2312 }, 2313 { 2314 "ADValue": "CP03_AVDD", "Callouts": [ 2315 { 2316 "CalloutList": [ 2317 { "Priority": "high", "LocCode": "P0-C58" }, 2318 { "Priority": "medium", "LocCode": "P0-C56" }, 2319 { "Priority": "medium", "LocCode": "P0-C61" }, 2320 { "Priority": "low", "LocCode": "P0" } 2321 ] 2322 } 2323 ] 2324 }, 2325 { 2326 "ADValue": "CP12_AVDD", "Callouts": [ 2327 { 2328 "CalloutList": [ 2329 { "Priority": "high", "LocCode": "P0-C16" }, 2330 { "Priority": "medium", "LocCode": "P0-C14" }, 2331 { "Priority": "medium", "LocCode": "P0-C19" }, 2332 { "Priority": "low", "LocCode": "P0" } 2333 ] 2334 } 2335 ] 2336 }, 2337 { 2338 "ADValue": "CP0_VDD0", "Callouts": [ 2339 { 2340 "CalloutList": [ 2341 { "Priority": "high", "LocCode": "P0-C62" }, 2342 { "Priority": "medium", "LocCode": "P0-C61" }, 2343 { "Priority": "low", "LocCode": "P0" } 2344 ] 2345 } 2346 ] 2347 }, 2348 { 2349 "ADValue": "CP0_VDD1", "Callouts": [ 2350 { 2351 "CalloutList": [ 2352 { "Priority": "high", "LocCode": "P0-C60" }, 2353 { "Priority": "medium", "LocCode": "P0-C61" }, 2354 { "Priority": "low", "LocCode": "P0" } 2355 ] 2356 } 2357 ] 2358 }, 2359 { 2360 "ADValue": "CP1_VDD0", "Callouts": [ 2361 { 2362 "CalloutList": [ 2363 { "Priority": "high", "LocCode": "P0-C13" }, 2364 { "Priority": "medium", "LocCode": "P0-C14" }, 2365 { "Priority": "low", "LocCode": "P0" } 2366 ] 2367 } 2368 ] 2369 }, 2370 { 2371 "ADValue": "CP1_VDD1", "Callouts": [ 2372 { 2373 "CalloutList": [ 2374 { "Priority": "high", "LocCode": "P0-C15" }, 2375 { "Priority": "medium", "LocCode": "P0-C14" }, 2376 { "Priority": "low", "LocCode": "P0" } 2377 ] 2378 } 2379 ] 2380 }, 2381 { 2382 "ADValue": "CP2_VDD0", "Callouts": [ 2383 { 2384 "CalloutList": [ 2385 { "Priority": "high", "LocCode": "P0-C18" }, 2386 { "Priority": "medium", "LocCode": "P0-C19" }, 2387 { "Priority": "low", "LocCode": "P0" } 2388 ] 2389 } 2390 ] 2391 }, 2392 { 2393 "ADValue": "CP2_VDD1", "Callouts": [ 2394 { 2395 "CalloutList": [ 2396 { "Priority": "high", "LocCode": "P0-C20" }, 2397 { "Priority": "medium", "LocCode": "P0-C19" }, 2398 { "Priority": "low", "LocCode": "P0" } 2399 ] 2400 } 2401 ] 2402 }, 2403 { 2404 "ADValue": "CP3_VDD0", "Callouts": [ 2405 { 2406 "CalloutList": [ 2407 { "Priority": "high", "LocCode": "P0-C57" }, 2408 { "Priority": "medium", "LocCode": "P0-C56" }, 2409 { "Priority": "low", "LocCode": "P0" } 2410 ] 2411 } 2412 ] 2413 }, 2414 { 2415 "ADValue": "CP3_VDD1", "Callouts": [ 2416 { 2417 "CalloutList": [ 2418 { "Priority": "high", "LocCode": "P0-C55" }, 2419 { "Priority": "medium", "LocCode": "P0-C56" }, 2420 { "Priority": "low", "LocCode": "P0" } 2421 ] 2422 } 2423 ] 2424 }, 2425 { 2426 "ADValue": "CP0_VCS0", "Callouts": [ 2427 { 2428 "CalloutList": [ 2429 { "Priority": "high", "LocCode": "P0-C63" }, 2430 { "Priority": "medium", "LocCode": "P0-C61" }, 2431 { "Priority": "low", "LocCode": "P0" } 2432 ] 2433 } 2434 ] 2435 }, 2436 { 2437 "ADValue": "CP0_VCS1", "Callouts": [ 2438 { 2439 "CalloutList": [ 2440 { "Priority": "high", "LocCode": "P0-C59" }, 2441 { "Priority": "medium", "LocCode": "P0-C61" }, 2442 { "Priority": "low", "LocCode": "P0" } 2443 ] 2444 } 2445 ] 2446 }, 2447 { 2448 "ADValue": "CP1_VCS0", "Callouts": [ 2449 { 2450 "CalloutList": [ 2451 { "Priority": "high", "LocCode": "P0-C12" }, 2452 { "Priority": "medium", "LocCode": "P0-C14" }, 2453 { "Priority": "low", "LocCode": "P0" } 2454 ] 2455 } 2456 ] 2457 }, 2458 { 2459 "ADValue": "CP1_VCS1", "Callouts": [ 2460 { 2461 "CalloutList": [ 2462 { "Priority": "high", "LocCode": "P0-C16" }, 2463 { "Priority": "medium", "LocCode": "P0-C14" }, 2464 { "Priority": "low", "LocCode": "P0" } 2465 ] 2466 } 2467 ] 2468 }, 2469 { 2470 "ADValue": "CP2_VCS0", "Callouts": [ 2471 { 2472 "CalloutList": [ 2473 { "Priority": "high", "LocCode": "P0-C17" }, 2474 { "Priority": "medium", "LocCode": "P0-C19" }, 2475 { "Priority": "low", "LocCode": "P0" } 2476 ] 2477 } 2478 ] 2479 }, 2480 { 2481 "ADValue": "CP2_VCS1", "Callouts": [ 2482 { 2483 "CalloutList": [ 2484 { "Priority": "high", "LocCode": "P0-C21" }, 2485 { "Priority": "medium", "LocCode": "P0-C19" }, 2486 { "Priority": "low", "LocCode": "P0" } 2487 ] 2488 } 2489 ] 2490 }, 2491 { 2492 "ADValue": "CP3_VCS0", "Callouts": [ 2493 { 2494 "CalloutList": [ 2495 { "Priority": "high", "LocCode": "P0-C58" }, 2496 { "Priority": "medium", "LocCode": "P0-C56" }, 2497 { "Priority": "low", "LocCode": "P0" } 2498 ] 2499 } 2500 ] 2501 }, 2502 { 2503 "ADValue": "CP3_VCS1", "Callouts": [ 2504 { 2505 "CalloutList": [ 2506 { "Priority": "high", "LocCode": "P0-C54" }, 2507 { "Priority": "medium", "LocCode": "P0-C56" }, 2508 { "Priority": "low", "LocCode": "P0" } 2509 ] 2510 } 2511 ] 2512 }, 2513 { 2514 "ADValue": "12.0VCS", "Callouts": [ 2515 { 2516 "CalloutList": [ 2517 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2518 ] 2519 } 2520 ] 2521 }, 2522 { 2523 "ADValue": "3.3VCS", "Callouts": [ 2524 { 2525 "CalloutList": [ 2526 { "Priority": "high", "LocCode": "P0" } 2527 ] 2528 } 2529 ] 2530 }, 2531 { 2532 "ADValue": "1.1V_Current", "Callouts": [ 2533 { 2534 "CalloutList": [ 2535 { "Priority": "high", "LocCode": "P0" } 2536 ] 2537 } 2538 ] 2539 }, 2540 { 2541 "ADValue": "5.0V_USB_Current", "Callouts": [ 2542 { 2543 "CalloutList": [ 2544 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2545 { "Priority": "medium", "LocCode": "P0" } 2546 ] 2547 } 2548 ] 2549 }, 2550 { 2551 "ADValue": "5.0V_DASD_Current", "Callouts": [ 2552 { 2553 "CalloutList": [ 2554 { "Priority": "medium", "LocCode": "P1" }, 2555 { "Priority": "medium", "LocCode": "P2" }, 2556 { "Priority": "medium", "LocCode": "P3" }, 2557 { "Priority": "low", "LocCode": "P0" } 2558 ] 2559 } 2560 ] 2561 }, 2562 { 2563 "ADValue": "12.0VN", "Callouts": [ 2564 { 2565 "CalloutList": [ 2566 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2567 ] 2568 } 2569 ] 2570 }, 2571 { 2572 "ADValue": "12.0VP", "Callouts": [ 2573 { 2574 "CalloutList": [ 2575 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2576 ] 2577 } 2578 ] 2579 }, 2580 { 2581 "ADValue": "12.0VQ", "Callouts": [ 2582 { 2583 "CalloutList": [ 2584 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2585 ] 2586 } 2587 ] 2588 }, 2589 { 2590 "ADValue": "12.0VR", "Callouts": [ 2591 { 2592 "CalloutList": [ 2593 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2594 ] 2595 } 2596 ] 2597 }, 2598 { 2599 "ADValue": "ThermalDiode1", "Callouts": [ 2600 { 2601 "CalloutList": [ 2602 { "Priority": "high", "LocCode": "P0" } 2603 ] 2604 } 2605 ] 2606 }, 2607 { 2608 "ADValue": "ThermalDiode2", "Callouts": [ 2609 { 2610 "CalloutList": [ 2611 { "Priority": "high", "LocCode": "P0" } 2612 ] 2613 } 2614 ] 2615 }, 2616 { 2617 "ADValue": "ThermalDiode3", "Callouts": [ 2618 { 2619 "CalloutList": [ 2620 { "Priority": "high", "LocCode": "P0" } 2621 ] 2622 } 2623 ] 2624 }, 2625 { 2626 "ADValue": "ThermalDiode4", "Callouts": [ 2627 { 2628 "CalloutList": [ 2629 { "Priority": "high", "LocCode": "P0" } 2630 ] 2631 } 2632 ] 2633 } 2634 ] 2635 }, 2636 2637 "Documentation": { 2638 "Description": "The power sequencer chip detected a voltage fault", 2639 "Message": "The power sequencer chip detected a voltage fault", 2640 "Notes": [ 2641 ] 2642 } 2643 }, 2644 2645 { 2646 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 2647 "Subsystem": "power", 2648 "Severity": "predictive_redundancy_loss", 2649 "ComponentID": "0x2700", 2650 2651 "SRC": { 2652 "Type": "11", 2653 "ReasonCode": "0x2700", 2654 "Words6To9": {} 2655 }, 2656 2657 "Documentation": { 2658 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 2659 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 2660 "Notes": [ 2661 "CALLOUT_INVENTORY_PATH should be specified in the ", 2662 "AdditionalData property of the event log so that ", 2663 "the device is called out but not the communication path." 2664 ] 2665 } 2666 }, 2667 2668 { 2669 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 2670 "Subsystem": "power", 2671 "Severity": "non_error", 2672 "MfgSeverity": "predictive_redundancy_loss", 2673 "ActionFlags": ["report"], 2674 "MfgActionFlags": ["service_action", "report", "call_home"], 2675 "ComponentID": "0x2700", 2676 2677 "SRC": { 2678 "Type": "11", 2679 "ReasonCode": "0x2701", 2680 "Words6To9": {} 2681 }, 2682 2683 "Documentation": { 2684 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 2685 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 2686 "Notes": [ 2687 "CALLOUT_INVENTORY_PATH should be specified in the ", 2688 "AdditionalData property of the event log so that ", 2689 "the device is called out but not the communication path." 2690 ] 2691 } 2692 }, 2693 2694 { 2695 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 2696 "Subsystem": "power", 2697 "ComponentID": "0x2700", 2698 2699 "SRC": { 2700 "Type": "11", 2701 "ReasonCode": "0x2900", 2702 "Words6To9": {} 2703 }, 2704 2705 "Documentation": { 2706 "Description": "A write verification error occurred on a device", 2707 "Message": "A write verification error occurred on a device", 2708 "Notes": [ 2709 "This error occurs when a device register is written, ", 2710 "read back, and the two values do not match. This is ", 2711 "also called a read-back error. The device should be ", 2712 "identified using the CALLOUT_DEVICE_PATH or ", 2713 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 2714 "AdditionalData property of the event log. This will ", 2715 "cause the device and the hardware in the communication ", 2716 "path to be called out." 2717 ] 2718 } 2719 }, 2720 2721 { 2722 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Discharging", 2723 "Subsystem": "power", 2724 "Severity": "non_error", 2725 "ActionFlags": ["report"], 2726 "ComponentID": "0x2700", 2727 2728 "SRC": { 2729 "Type": "11", 2730 "ReasonCode": "0x4201", 2731 "Words6To9": {} 2732 }, 2733 2734 "Documentation": { 2735 "Description": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 2736 "Message": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 2737 "Notes": [ 2738 ] 2739 } 2740 }, 2741 2742 { 2743 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Low", 2744 "Subsystem": "power", 2745 "Severity": "non_error", 2746 "ActionFlags": ["report"], 2747 "ComponentID": "0x2700", 2748 2749 "SRC": { 2750 "Type": "11", 2751 "ReasonCode": "0x4203", 2752 "Words6To9": {} 2753 }, 2754 2755 "Documentation": { 2756 "Description": "The Uninterruptible Power Supply (UPS) battery level is low", 2757 "Message": "The Uninterruptible Power Supply (UPS) battery level is low", 2758 "Notes": [ 2759 ] 2760 } 2761 }, 2762 2763 { 2764 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 2765 "Subsystem": "power", 2766 "ComponentID": "0x2700", 2767 2768 "SRC": { 2769 "Type": "11", 2770 "ReasonCode": "0xA013", 2771 "Words6To9": {} 2772 }, 2773 2774 "Callouts": [ 2775 { 2776 "CalloutList": [ 2777 { "Priority": "high", "Procedure": "bmc_code" } 2778 ] 2779 } 2780 ], 2781 2782 "Documentation": { 2783 "Description": "A regulators configuration file error occurred", 2784 "Message": "A regulators configuration file error occurred", 2785 "Notes": [ 2786 "The regulators configuration file could not be found, ", 2787 "could not be read, or had invalid contents." 2788 ] 2789 } 2790 }, 2791 2792 { 2793 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 2794 "Subsystem": "power", 2795 "Severity": "critical_system_term", 2796 "ComponentID": "0x2700", 2797 2798 "SRC": { 2799 "Type": "11", 2800 "ReasonCode": "0xA014", 2801 "Words6To9": {} 2802 }, 2803 2804 "Callouts": [ 2805 { 2806 "CalloutList": [ 2807 { "Priority": "high", "Procedure": "bmc_code" } 2808 ] 2809 } 2810 ], 2811 2812 "Documentation": { 2813 "Description": "A critical regulators configuration file error occurred", 2814 "Message": "A critical regulators configuration file error occurred", 2815 "Notes": [ 2816 "The regulators configuration file could not be found, ", 2817 "could not be read, or had invalid contents. As a result ", 2818 "voltage regulators could not be configured, and the ", 2819 "chassis could not be powered on." 2820 ] 2821 } 2822 }, 2823 2824 { 2825 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 2826 "Subsystem": "power_sequencer", 2827 "ComponentID": "0x2700", 2828 2829 "SRC": { 2830 "Type": "11", 2831 "ReasonCode": "0xD000", 2832 "Words6To9": {} 2833 }, 2834 2835 "Callouts": [ 2836 { 2837 "CalloutList": [ 2838 { "Priority": "high", "LocCode": "P0" } 2839 ] 2840 } 2841 ], 2842 2843 "Documentation": { 2844 "Description": "The power sequencer chip detected a fault", 2845 "Message": "The power sequencer chip detected a fault", 2846 "Notes": [ 2847 ] 2848 } 2849 }, 2850 2851 { 2852 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 2853 "Subsystem": "power_sequencer", 2854 "ComponentID": "0x2700", 2855 "Severity": "critical", 2856 2857 "SRC": { 2858 "Type": "11", 2859 "ReasonCode": "0xD002", 2860 "Words6To9": {} 2861 }, 2862 2863 "Callouts": [ 2864 { 2865 "CalloutList": [ 2866 { "Priority": "high", "LocCode": "P0" } 2867 ] 2868 } 2869 ], 2870 2871 "Documentation": { 2872 "Description": "System power failed to turn on within timeout period", 2873 "Message": "System power failed to turn on within timeout period", 2874 "Notes": [ 2875 ] 2876 } 2877 }, 2878 2879 { 2880 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 2881 "Subsystem": "power_sequencer", 2882 "ComponentID": "0x2700", 2883 "Severity": "critical", 2884 2885 "SRC": { 2886 "Type": "11", 2887 "ReasonCode": "0xD008", 2888 "Words6To9": {} 2889 }, 2890 2891 "Callouts": [ 2892 { 2893 "CalloutList": [ 2894 { "Priority": "high", "LocCode": "P0" } 2895 ] 2896 } 2897 ], 2898 2899 "Documentation": { 2900 "Description": "System power failed to turn off within timeout period", 2901 "Message": "System power failed to turn off within timeout period", 2902 "Notes": [ 2903 ] 2904 } 2905 }, 2906 2907 { 2908 "Name": "xyz.openbmc_project.Power.Error.Internal", 2909 "Subsystem": "power", 2910 "ComponentID": "0x2700", 2911 2912 "SRC": { 2913 "Type": "11", 2914 "ReasonCode": "0xE000", 2915 "Words6To9": {} 2916 }, 2917 2918 "Callouts": [ 2919 { 2920 "CalloutList": [ 2921 { "Priority": "high", "Procedure": "bmc_code" } 2922 ] 2923 } 2924 ], 2925 2926 "Documentation": { 2927 "Description": "An internal firmware error occurred", 2928 "Message": "An internal firmware error occurred", 2929 "Notes": [ 2930 "The error details must be provided in the AdditionalData ", 2931 "property of the event log." 2932 ] 2933 } 2934 }, 2935 2936 { 2937 "Name": "xyz.openbmc_project.Power.Error.I2C", 2938 "Subsystem": "cec_i2c", 2939 "ComponentID": "0x2700", 2940 2941 "SRC": { 2942 "Type": "11", 2943 "ReasonCode": "0xE100", 2944 "Words6To9": {} 2945 }, 2946 2947 "Documentation": { 2948 "Description": "An I2C error occurred communicating with a device", 2949 "Message": "An I2C error occurred communicating with a device", 2950 "Notes": [ 2951 "The device should be identified using the ", 2952 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 2953 "keywords in the AdditionalData property of the event ", 2954 "log. This will cause the device and the hardware in the ", 2955 "communication path to be called out." 2956 ] 2957 } 2958 }, 2959 2960 { 2961 "Name": "xyz.openbmc_project.Power.Error.PMBus", 2962 "Subsystem": "power", 2963 "ComponentID": "0x2700", 2964 2965 "SRC": { 2966 "Type": "11", 2967 "ReasonCode": "0xE200", 2968 "Words6To9": {} 2969 }, 2970 2971 "Documentation": { 2972 "Description": "A PMBus error occurred on a device", 2973 "Message": "A PMBus error occurred on a device", 2974 "Notes": [ 2975 "This error occurs when the I2C communication was ", 2976 "successful, but the PMBus value read is invalid or ", 2977 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 2978 "in the AdditionalData property of the event log so that ", 2979 "the device is called out but not the communication path." 2980 ] 2981 } 2982 }, 2983 2984 { 2985 "Name": "xyz.openbmc_project.Power.Error.DBus", 2986 "Subsystem": "power", 2987 "ComponentID": "0x2700", 2988 2989 "SRC": { 2990 "Type": "11", 2991 "ReasonCode": "0xE300", 2992 "Words6To9": {} 2993 }, 2994 2995 "Callouts": [ 2996 { 2997 "CalloutList": [ 2998 { "Priority": "high", "Procedure": "bmc_code" } 2999 ] 3000 } 3001 ], 3002 3003 "Documentation": { 3004 "Description": "A firmware inter-process communication (D-Bus) error occurred", 3005 "Message": "A firmware inter-process communication (D-Bus) error occurred" 3006 } 3007 }, 3008 3009 { 3010 "Name": "xyz.openbmc_project.Fan.Error.Fault", 3011 "Subsystem": "power_fans", 3012 "ComponentID": "0x2800", 3013 3014 "SRC": { 3015 "Type": "11", 3016 "ReasonCode": "0x76F0", 3017 "Words6To9": {} 3018 }, 3019 3020 "Documentation": { 3021 "Description": "Fan rotor fault", 3022 "Message": "Fan rotor fault", 3023 "Notes": [ 3024 "This error occurs when a fan rotor has been faulted for a ", 3025 "certain amount of time. The callout is the fan which is ", 3026 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 3027 "passed in during creation and will be either informational ", 3028 "or unrecoverable. The action flags use the defaults and ", 3029 "vary based on the severity." 3030 ] 3031 } 3032 }, 3033 3034 { 3035 "Name": "xyz.openbmc_project.Fan.Error.Missing", 3036 "Subsystem": "power_fans", 3037 "ComponentID": "0x2800", 3038 "Severity": "unrecoverable_redundancy_loss", 3039 "ActionFlags": ["service_action", "report", "call_home"], 3040 3041 "SRC": { 3042 "Type": "11", 3043 "ReasonCode": "0x76F1", 3044 "Words6To9": {} 3045 }, 3046 3047 "Callouts": [ 3048 { 3049 "System": "ibm,rainier", 3050 "CalloutList": [ 3051 { 3052 "Priority": "high", 3053 "SymbolicFRUTrusted": "air_mover", 3054 "UseInventoryLocCode": true 3055 }, 3056 { 3057 "Priority": "low", 3058 "LocCode": "P0" 3059 } 3060 ] 3061 }, 3062 { 3063 "System": "ibm,everest", 3064 "CalloutList": [ 3065 { 3066 "Priority": "high", 3067 "SymbolicFRUTrusted": "air_mover", 3068 "UseInventoryLocCode": true 3069 }, 3070 { 3071 "Priority": "low", 3072 "LocCode": "P1" 3073 } 3074 ] 3075 } 3076 ], 3077 3078 "Documentation": { 3079 "Description": "A fan is missing", 3080 "Message": "A fan is missing", 3081 "Notes": [ 3082 "This error occurs when a fan has been missing for a ", 3083 "certain amount of time. The first callout is the ", 3084 "symbolic FRU AIR_MOVR that has the trusted fan location ", 3085 "code, which it gets using the passed in ", 3086 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 3087 "where the controller and GPIO expander are." 3088 ] 3089 } 3090 }, 3091 3092 { 3093 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 3094 "ComponentID": "0x2800", 3095 "Subsystem": "power_fans", 3096 "Severity": "non_error", 3097 "ActionFlags": ["report"], 3098 "MfgSeverity": "predictive", 3099 "MfgActionFlags": ["service_action", "report"], 3100 3101 "SRC": { 3102 "Type": "11", 3103 "ReasonCode": "0x76F2", 3104 "Words6To9": {} 3105 }, 3106 3107 "Callouts": [ 3108 { 3109 "System": "ibm,rainier", 3110 "CalloutList": [ 3111 {"Priority": "medium", "LocCode": "P0"} 3112 ] 3113 }, 3114 { 3115 "System": "ibm,everest", 3116 "CalloutList": [ 3117 {"Priority": "medium", "LocCode": "P1"} 3118 ] 3119 } 3120 ], 3121 3122 "Documentation": { 3123 "Description": "Presence detect methods for the same fan disagree", 3124 "Message": "Presence detect methods for the same fan disagree", 3125 "Notes": [ 3126 "This error occurs when there is more than one way to detect", 3127 "fan presence, and they don't all agree. For example, the", 3128 "GPIO says a fan isn't present, but the tach readings are", 3129 "nonzero. This is informational, unless in manufacturing.", 3130 "The fan FRU is passed in as a high priority callout.", 3131 "The FRU the GPIO source is on is called out medium." 3132 ] 3133 } 3134 }, 3135 3136 { 3137 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 3138 "ComponentID": "0x2800", 3139 "Subsystem": "power_fans", 3140 "Severity": "critical_system_term", 3141 "ActionFlags": ["service_action", "report", "call_home"], 3142 3143 "SRC": { 3144 "Type": "11", 3145 "ReasonCode": "0x76F3", 3146 "Words6To9": {} 3147 }, 3148 3149 "Callouts": [ 3150 { 3151 "System": "ibm,rainier", 3152 "CalloutList": [ 3153 {"Priority": "high", "LocCode": "P0-C5"}, 3154 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 3155 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 3156 {"Priority": "low", "LocCode": "P0"} 3157 ] 3158 }, 3159 { 3160 "System": "ibm,everest", 3161 "CalloutList": [ 3162 {"Priority": "high", "LocCode": "P0-C0"}, 3163 {"Priority": "medium", "LocCode": "P1"}, 3164 {"Priority": "low", "LocCode": "P0"} 3165 ] 3166 } 3167 ], 3168 3169 "Documentation": { 3170 "Description": "The fan controller device is offline", 3171 "Message": "The fan controller is offline. The system must be powered off.", 3172 "Notes": [ 3173 "The device that controls the fans is offline so the fan", 3174 "targets and speeds are unknown. The system will be shut", 3175 "down to preserve thermal safety. There may be an I2C", 3176 "or power problem with the device." 3177 ] 3178 } 3179 }, 3180 3181 { 3182 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 3183 "Subsystem": "power_fans", 3184 "ComponentID": "0x2800", 3185 "Severity": "unrecoverable_redundancy_loss", 3186 "ActionFlags": ["service_action", "report", "call_home"], 3187 3188 "SRC": { 3189 "Type": "11", 3190 "ReasonCode": "0x76F4", 3191 "Words6To9": {} 3192 }, 3193 3194 "Callouts": [ 3195 { 3196 "System" : "ibm,rainier", 3197 "CalloutList": [ 3198 {"Priority": "high", "LocCode": "P0-C5"}, 3199 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 3200 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 3201 {"Priority": "low", "LocCode": "P0"} 3202 ] 3203 }, 3204 { 3205 "System" : "ibm,everest", 3206 "CalloutList": [ 3207 {"Priority": "high", "LocCode": "P0-C0"}, 3208 {"Priority": "medium", "LocCode": "P1"}, 3209 {"Priority": "low", "LocCode": "P0"} 3210 ] 3211 } 3212 ], 3213 3214 "Documentation": { 3215 "Description": "Fan GPIO sensors not present", 3216 "Message": "Fan GPIO sensors not present", 3217 "Notes": [ 3218 "The device that reports fan presence is not functioning." 3219 ] 3220 } 3221 }, 3222 3223 { 3224 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 3225 "Subsystem": "power", 3226 "ComponentID": "0x2800", 3227 "Severity": "predictive", 3228 "ActionFlags": ["service_action", "report"], 3229 3230 "SRC": { 3231 "ReasonCode": "0x2801", 3232 "Words6To9": {} 3233 }, 3234 3235 "CalloutsUsingAD": { 3236 "ADName": "SENSOR_NAME", 3237 "CalloutsWithTheirADValues": [ 3238 { 3239 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3240 "Callouts": [ 3241 { 3242 "CalloutList": [ 3243 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3244 ] 3245 } 3246 ] 3247 } 3248 ] 3249 }, 3250 3251 "Documentation": { 3252 "Description": "A temperature sensor exceeded its performance loss threshold.", 3253 "Message": "A temperature sensor exceeded its performance loss threshold.", 3254 "Notes": [ 3255 "A temperature sensor crossed its performance loss threshold value", 3256 "If it is the ambient sensor, then a symbolic FRU will be added.", 3257 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3258 "a FRU callout." 3259 ] 3260 } 3261 }, 3262 3263 { 3264 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 3265 "Subsystem": "power", 3266 "ComponentID": "0x2800", 3267 "Severity": "non_error", 3268 "ActionFlags": ["report"], 3269 "EventType": "env_normal", 3270 3271 "SRC": { 3272 "ReasonCode": "0x2802", 3273 "Words6To9": {} 3274 }, 3275 3276 "CalloutsUsingAD": { 3277 "ADName": "SENSOR_NAME", 3278 "CalloutsWithTheirADValues": [ 3279 { 3280 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3281 "Callouts": [ 3282 { 3283 "CalloutList": [ 3284 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3285 ] 3286 } 3287 ] 3288 } 3289 ] 3290 }, 3291 3292 "Documentation": { 3293 "Description": "A temperature sensor is under its performance loss threshold.", 3294 "Message": "A temperature sensor is under its performance loss threshold.", 3295 "Notes": [ 3296 "A temperature sensor crossed under its performance loss threshold value", 3297 "If it is the ambient sensor, then a symbolic FRU will be added." 3298 ] 3299 } 3300 }, 3301 3302 { 3303 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 3304 "Subsystem": "power", 3305 "ComponentID": "0x2800", 3306 "Severity": "predictive", 3307 "ActionFlags": ["service_action", "report"], 3308 3309 "SRC": { 3310 "ReasonCode": "0x2803", 3311 "Words6To9": {} 3312 }, 3313 3314 "CalloutsUsingAD": { 3315 "ADName": "SENSOR_NAME", 3316 "CalloutsWithTheirADValues": [ 3317 { 3318 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3319 "Callouts": [ 3320 { 3321 "CalloutList": [ 3322 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3323 ] 3324 } 3325 ] 3326 } 3327 ] 3328 }, 3329 3330 "Documentation": { 3331 "Description": "A temperature sensor exceeded its warning threshold.", 3332 "Message": "A temperature sensor exceeded its warning threshold.", 3333 "Notes": [ 3334 "A temperature sensor crossed its warning threshold value", 3335 "If it is the ambient sensor, then a symbolic FRU will be added.", 3336 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3337 "a FRU callout." 3338 ] 3339 } 3340 }, 3341 3342 { 3343 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 3344 "Subsystem": "power", 3345 "ComponentID": "0x2800", 3346 "Severity": "non_error", 3347 "ActionFlags": ["report"], 3348 "EventType": "env_normal", 3349 3350 "SRC": { 3351 "ReasonCode": "0x2804", 3352 "Words6To9": {} 3353 }, 3354 3355 "CalloutsUsingAD": { 3356 "ADName": "SENSOR_NAME", 3357 "CalloutsWithTheirADValues": [ 3358 { 3359 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3360 "Callouts": [ 3361 { 3362 "CalloutList": [ 3363 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3364 ] 3365 } 3366 ] 3367 } 3368 ] 3369 }, 3370 3371 "Documentation": { 3372 "Description": "A temperature sensor is under its warning threshold.", 3373 "Message": "A temperature sensor is under its warning threshold.", 3374 "Notes": [ 3375 "A temperature sensor crossed under its warning threshold value", 3376 "If it is the ambient sensor, then a symbolic FRU will be added." 3377 ] 3378 } 3379 }, 3380 3381 { 3382 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 3383 "Subsystem": "power", 3384 "ComponentID": "0x2800", 3385 "Severity": "predictive", 3386 "ActionFlags": ["service_action", "report"], 3387 3388 "SRC": { 3389 "ReasonCode": "0x2805", 3390 "Words6To9": {} 3391 }, 3392 3393 "CalloutsUsingAD": { 3394 "ADName": "SENSOR_NAME", 3395 "CalloutsWithTheirADValues": [ 3396 { 3397 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3398 "Callouts": [ 3399 { 3400 "CalloutList": [ 3401 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3402 ] 3403 } 3404 ] 3405 } 3406 ] 3407 }, 3408 3409 "Documentation": { 3410 "Description": "A temperature sensor exceeded its critical threshold.", 3411 "Message": "A temperature sensor exceeded its critical threshold.", 3412 "Notes": [ 3413 "A temperature sensor crossed its critical threshold value", 3414 "If it is the ambient sensor, then a symbolic FRU will be added.", 3415 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3416 "a FRU callout." 3417 ] 3418 } 3419 }, 3420 3421 { 3422 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 3423 "Subsystem": "power", 3424 "ComponentID": "0x2800", 3425 "Severity": "non_error", 3426 "ActionFlags": ["report"], 3427 "EventType": "env_normal", 3428 3429 "SRC": { 3430 "ReasonCode": "0x2806", 3431 "Words6To9": {} 3432 }, 3433 3434 "CalloutsUsingAD": { 3435 "ADName": "SENSOR_NAME", 3436 "CalloutsWithTheirADValues": [ 3437 { 3438 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3439 "Callouts": [ 3440 { 3441 "CalloutList": [ 3442 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3443 ] 3444 } 3445 ] 3446 } 3447 ] 3448 }, 3449 3450 "Documentation": { 3451 "Description": "A temperature sensor is under its critical threshold.", 3452 "Message": "A temperature sensor is under its critical threshold.", 3453 "Notes": [ 3454 "A temperature sensor crossed under its critical threshold value", 3455 "If it is the ambient sensor, then a symbolic FRU will be added." 3456 ] 3457 } 3458 }, 3459 3460 { 3461 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 3462 "Subsystem": "power", 3463 "ComponentID": "0x2800", 3464 "Severity": "predictive", 3465 "ActionFlags": ["service_action", "report"], 3466 3467 "SRC": { 3468 "ReasonCode": "0x2807", 3469 "Words6To9": {} 3470 }, 3471 3472 "Callouts": [ 3473 { 3474 "CalloutList": [ 3475 { 3476 "Priority": "high", 3477 "SymbolicFRU": "ambient_temp" 3478 } 3479 ] 3480 } 3481 ], 3482 3483 "Documentation": { 3484 "Description": "The ambient temperature passed the EPOW3 limit.", 3485 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 3486 "Notes": [ 3487 "This error occurs when the ambient temperature surpassed", 3488 "the EPOW3 shutdown limit." 3489 ] 3490 } 3491 }, 3492 3493 { 3494 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 3495 "Subsystem": "power", 3496 "ComponentID": "0x2800", 3497 "Severity": "non_error", 3498 "ActionFlags": ["report"], 3499 "EventType": "env_normal", 3500 3501 "SRC": { 3502 "ReasonCode": "0x2808", 3503 "Words6To9": {} 3504 }, 3505 3506 "Callouts": [ 3507 { 3508 "CalloutList": [ 3509 { 3510 "Priority": "high", 3511 "SymbolicFRU": "ambient_temp_back" 3512 } 3513 ] 3514 } 3515 ], 3516 3517 "Documentation": { 3518 "Description": "The ambient temperature is back under the EPOW3 limit.", 3519 "Message": "The ambient temperature is back under the EPOW3 limit." 3520 } 3521 }, 3522 3523 { 3524 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 3525 "Subsystem": "power", 3526 "ComponentID": "0x2800", 3527 "ActionFlags": ["service_action", "report"], 3528 3529 "SRC": { 3530 "ReasonCode": "0x2809", 3531 "Words6To9": {} 3532 }, 3533 3534 "Callouts": [ 3535 { 3536 "CalloutList": [ 3537 { 3538 "Priority": "high", 3539 "SymbolicFRU": "ambient_temp" 3540 } 3541 ] 3542 } 3543 ], 3544 3545 "Documentation": { 3546 "Description": "The ambient temperature passed the EPOW4 limit.", 3547 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 3548 "Notes": [ 3549 "This error occurs when the ambient temperature surpassed", 3550 "the EPOW4 shutdown limit." 3551 ] 3552 } 3553 }, 3554 3555 { 3556 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 3557 "Subsystem": "ext_env", 3558 "ComponentID": "0x2800", 3559 "Severity": "predictive", 3560 "ActionFlags": ["service_action", "report"], 3561 3562 "SRC": { 3563 "ReasonCode": "0x280A", 3564 "Words6To9": {} 3565 }, 3566 3567 "CalloutsUsingAD": { 3568 "ADName": "SENSOR_NAME", 3569 "CalloutsWithTheirADValues": [ 3570 { 3571 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 3572 "Callouts": [ 3573 { 3574 "CalloutList": [ 3575 { "Priority": "high", "SymbolicFRU": "altitude" } 3576 ] 3577 } 3578 ] 3579 } 3580 ] 3581 }, 3582 3583 "Documentation": { 3584 "Description": "An altitude sensor exceeded its warning threshold.", 3585 "Message": "An altitude sensor exceeded its warning threshold.", 3586 "Notes": [ 3587 "The virtual altitude sensor crossed its warning threshold value", 3588 " and a symbolic FRU will be added." 3589 ] 3590 } 3591 }, 3592 3593 { 3594 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 3595 "Subsystem": "ext_env", 3596 "ComponentID": "0x2800", 3597 "Severity": "non_error", 3598 "ActionFlags": ["report"], 3599 "EventType": "env_normal", 3600 3601 "SRC": { 3602 "ReasonCode": "0x280B", 3603 "Words6To9": {} 3604 }, 3605 3606 "Documentation": { 3607 "Description": "An altitude sensor is under its warning threshold.", 3608 "Message": "An altitude sensor is under its warning threshold.", 3609 "Notes": [ 3610 "The virtual altitude sensor is under its warning threshold value", 3611 " and a symbolic FRU will be added." 3612 ] 3613 } 3614 }, 3615 3616 { 3617 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 3618 "Subsystem": "cec_tod", 3619 "ComponentID": "0x2800", 3620 "Severity": "predictive", 3621 "ActionFlags": ["service_action", "report"], 3622 3623 "SRC": { 3624 "ReasonCode": "0x280C", 3625 "Words6To9": {} 3626 }, 3627 3628 "Documentation": { 3629 "Description": "A voltage sensor went below its critical low threshold.", 3630 "Message": "A voltage sensor went below its critical low threshold." 3631 } 3632 }, 3633 3634 { 3635 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 3636 "Subsystem": "cec_tod", 3637 "ComponentID": "0x2800", 3638 "Severity": "non_error", 3639 "ActionFlags": ["report"], 3640 3641 "SRC": { 3642 "ReasonCode": "0x280D", 3643 "Words6To9": {} 3644 }, 3645 3646 "Documentation": { 3647 "Description": "A voltage sensor is over its critical low threshold.", 3648 "Message": "A voltage sensor is over its critical low threshold." 3649 } 3650 }, 3651 3652 { 3653 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLow", 3654 "Subsystem": "power", 3655 "ComponentID": "0x2800", 3656 "Severity": "predictive", 3657 "ActionFlags": ["service_action", "report"], 3658 3659 "SRC": { 3660 "ReasonCode": "0x280E", 3661 "Words6To9": {} 3662 }, 3663 3664 "Documentation": { 3665 "Description": "A temperature sensor is under its low warning threshold.", 3666 "Message": "A temperature sensor is under its low warning threshold.", 3667 "Notes": [ 3668 "A temperature sensor crossed its low warning threshold value", 3669 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 3670 ] 3671 } 3672 }, 3673 3674 { 3675 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLowClear", 3676 "Subsystem": "power", 3677 "ComponentID": "0x2800", 3678 "Severity": "non_error", 3679 "ActionFlags": ["report"], 3680 "EventType": "env_normal", 3681 3682 "SRC": { 3683 "ReasonCode": "0x280F", 3684 "Words6To9": {} 3685 }, 3686 3687 "Documentation": { 3688 "Description": "A temperature sensor is above its low warning threshold.", 3689 "Message": "A temperature sensor is above its low warning threshold.", 3690 "Notes": [ 3691 "A temperature sensor crossed above its low warning threshold value." 3692 ] 3693 } 3694 }, 3695 3696 { 3697 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLow", 3698 "Subsystem": "power", 3699 "ComponentID": "0x2800", 3700 "Severity": "predictive", 3701 "ActionFlags": ["service_action", "report"], 3702 3703 "SRC": { 3704 "ReasonCode": "0x2810", 3705 "Words6To9": {} 3706 }, 3707 3708 "Documentation": { 3709 "Description": "A temperature sensor is under its low critical threshold.", 3710 "Message": "A temperature sensor is under its low critical threshold.", 3711 "Notes": [ 3712 "A temperature sensor crossed its low critical threshold value", 3713 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 3714 ] 3715 } 3716 }, 3717 3718 { 3719 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLowClear", 3720 "Subsystem": "power", 3721 "ComponentID": "0x2800", 3722 "Severity": "non_error", 3723 "ActionFlags": ["report"], 3724 "EventType": "env_normal", 3725 3726 "SRC": { 3727 "ReasonCode": "0x2811", 3728 "Words6To9": {} 3729 }, 3730 3731 "Documentation": { 3732 "Description": "A temperature sensor is over its low critical threshold.", 3733 "Message": "A temperature sensor is over its low critical threshold.", 3734 "Notes": [ 3735 "A temperature sensor crossed above its critical threshold value" 3736 ] 3737 } 3738 }, 3739 3740 { 3741 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 3742 "Subsystem": "cec_vpd", 3743 "ComponentID": "0x4000", 3744 3745 "SRC": { 3746 "ReasonCode": "0x4000", 3747 "Words6To9": 3748 { 3749 "6": 3750 { 3751 "Description": "Errno of the failure.", 3752 "AdditionalDataPropSource": "CALLOUT_ERRNO" 3753 } 3754 } 3755 }, 3756 3757 "Documentation": { 3758 "Description": "A path access error ocurred", 3759 "Message": "An EEPROM path access error occurred.", 3760 "Notes": [ 3761 "This error occurs when parser is unable to access", 3762 "EEPROM path. Errno and device path are captured as", 3763 "additional data." 3764 ] 3765 } 3766 }, 3767 3768 { 3769 "Name": "com.ibm.VPD.Error.InvalidVPD", 3770 "Subsystem": "cec_vpd", 3771 "ComponentID": "0x4000", 3772 3773 "SRC": { 3774 "ReasonCode": "0x4001", 3775 "Words6To9": 3776 { 3777 } 3778 }, 3779 3780 "Documentation": { 3781 "Description": "Invalid VPD data.", 3782 "Message": "A VPD data exception occurred.", 3783 "Notes": [ 3784 "This error occurs when VPD data is found to be", 3785 "invalid. This can be when VPD file is missing out", 3786 "mandatory records.Inventory path is captured in", 3787 "additional data." 3788 ] 3789 } 3790 }, 3791 3792 { 3793 "Name": "com.ibm.VPD.Error.EccCheckFailed", 3794 "Subsystem": "cec_vpd", 3795 "ComponentID": "0x4000", 3796 3797 "SRC": { 3798 "ReasonCode": "0x4002", 3799 "Words6To9": 3800 { 3801 } 3802 }, 3803 3804 "Documentation": { 3805 "Description": "Invalid VPD ecc data.", 3806 "Message": "A VPD ecc exception occurred.", 3807 "Notes": [ 3808 "This error occurs when VPD ecc check fails for the FRU.", 3809 "Inventory path for the failed FRU is captured in additonal", 3810 "data." 3811 ] 3812 } 3813 }, 3814 3815 { 3816 "Name": "com.ibm.VPD.Error.InvalidJson", 3817 "Subsystem": "cec_vpd", 3818 "ComponentID": "0x4000", 3819 3820 "SRC": { 3821 "ReasonCode": "0x4003", 3822 "Words6To9": 3823 { 3824 } 3825 }, 3826 3827 "Callouts": [ 3828 { 3829 "CalloutList": [ 3830 { "Priority": "high", "Procedure": "bmc_code" } 3831 ] 3832 } 3833 ], 3834 3835 "Documentation": { 3836 "Description": "Invalid Json", 3837 "Message": "A Json failure occurred.", 3838 "Notes": [ 3839 "This error occurs when parser fails to access", 3840 "Json file or there is any issue with Json data.", 3841 "Failed Json path and cause of failure is captured", 3842 "in additional data." 3843 ] 3844 } 3845 }, 3846 3847 { 3848 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 3849 "Subsystem": "cec_vpd", 3850 "ComponentID": "0x4000", 3851 3852 "SRC": { 3853 "ReasonCode": "0x4004", 3854 "Words6To9": 3855 { 3856 } 3857 }, 3858 3859 "Documentation": { 3860 "Description": "System VPD restore failed", 3861 "Message": "A system VPD restoration error occurred.", 3862 "Notes": [ 3863 "This error occurs when restoring of system VPD fails.", 3864 "The FRU path and reason for failure is captured in", 3865 "additional data." 3866 ] 3867 } 3868 }, 3869 3870 { 3871 "Name": "com.ibm.VPD.Error.DbusFailure", 3872 "Subsystem": "cec_vpd", 3873 "ComponentID": "0x4000", 3874 3875 "SRC": { 3876 "ReasonCode": "0x4005", 3877 "Words6To9": 3878 { 3879 } 3880 }, 3881 3882 "Callouts": [ 3883 { 3884 "CalloutList": [ 3885 { "Priority": "high", "Procedure": "bmc_code" } 3886 ] 3887 } 3888 ], 3889 3890 "Documentation": { 3891 "Description": "Dbus exception", 3892 "Message": "A Dbus internal error occurred.", 3893 "Notes": [ 3894 "This error occurs when Dbus operation fails.", 3895 "Exceptions details are captured in additonal", 3896 "data." 3897 ] 3898 } 3899 }, 3900 3901 { 3902 "Name": "com.ibm.VPD.Error.UnknownSystemType", 3903 "Subsystem": "cec_vpd", 3904 "ComponentID": "0x4000", 3905 3906 "SRC": { 3907 "ReasonCode": "0x4006", 3908 "Words6To9": 3909 { 3910 } 3911 }, 3912 3913 "Callouts": [ 3914 { 3915 "CalloutList": [ 3916 { "Priority": "high", "LocCode": "P0" } 3917 ] 3918 } 3919 ], 3920 3921 "Documentation": { 3922 "Description": "Unknown System Type", 3923 "Message": "System type not supported in DTB table.", 3924 "Notes": [ 3925 "System type comes from combination of HW and IM value of system VPD.", 3926 "If anything gets changed in that combination, then it can't determine", 3927 "the appropriate DTB for that system. Need to check HW and IM keywords." 3928 ] 3929 } 3930 }, 3931 3932 { 3933 "Name": "com.ibm.VPD.Error.GPIOError", 3934 "Subsystem": "cec_vpd", 3935 "ComponentID": "0x4000", 3936 3937 "SRC": { 3938 "ReasonCode": "0x4007", 3939 "Words6To9": 3940 { 3941 } 3942 }, 3943 3944 "Documentation": { 3945 "Description": "GPIO line error", 3946 "Message": "GPIO line couldn't be found or read.", 3947 "Notes": [ 3948 "The BMC could not access a GPIO line. This generally means that the", 3949 " hardware had issues toggling the line and/or the device driver has", 3950 " not exposed the GPIO line to userspace due to underlying I2C issues.", 3951 " The I2C path will be called out." 3952 ] 3953 } 3954 }, 3955 3956 { 3957 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 3958 "Subsystem": "cec_sp_hostboot_iface", 3959 3960 "SRC": 3961 { 3962 "ReasonCode": "0xC101", 3963 "Words6To9": 3964 { 3965 } 3966 }, 3967 3968 "Documentation": 3969 { 3970 "Description": "Host did not respond within the watchdog timeout interval", 3971 "Message": "Host did not respond before the watchdog timeout interval expired", 3972 "Notes": [ 3973 "Host did not respond before the expiry of the watchdog timeout interval.", 3974 "Collecting hostboot dump." 3975 ] 3976 } 3977 }, 3978 3979 { 3980 "Name": "xyz.openbmc_project.Software.Version.Error.Incompatible", 3981 "Subsystem": "bmc_firmware", 3982 "ComponentID": "0x3600", 3983 "SRC": 3984 { 3985 "ReasonCode": "0x3601", 3986 "Words6To9": 3987 { 3988 } 3989 }, 3990 3991 "Callouts": [ 3992 { 3993 "CalloutList": [ 3994 { "Priority": "high", "Procedure": "bmc_code" } 3995 ] 3996 } 3997 ], 3998 3999 "Documentation": 4000 { 4001 "Description": "A system component has a software version that is incompatible.", 4002 "Message": "A system component has a software version that is incompatible." 4003 } 4004 }, 4005 4006 { 4007 "Name": "xyz.openbmc_project.Software.Version.Error.AlreadyExists", 4008 "Subsystem": "bmc_firmware", 4009 "ComponentID": "0x3600", 4010 "SRC": 4011 { 4012 "ReasonCode": "0x3602", 4013 "Words6To9": 4014 { 4015 } 4016 }, 4017 4018 "Callouts": [ 4019 { 4020 "CalloutList": [ 4021 { "Priority": "high", "Procedure": "bmc_code" } 4022 ] 4023 } 4024 ], 4025 4026 "Documentation": 4027 { 4028 "Description": "This image version already exists on the device.", 4029 "Message": "This image version already exists on the device." 4030 } 4031 }, 4032 4033 { 4034 "Name": "xyz.openbmc_project.Software.Image.Error.UnTarFailure", 4035 "Subsystem": "bmc_firmware", 4036 "ComponentID": "0x3600", 4037 "SRC": 4038 { 4039 "ReasonCode": "0x3603", 4040 "Words6To9": 4041 { 4042 } 4043 }, 4044 4045 "Callouts": [ 4046 { 4047 "CalloutList": [ 4048 { "Priority": "high", "Procedure": "bmc_code" } 4049 ] 4050 } 4051 ], 4052 4053 "Documentation": 4054 { 4055 "Description": "An error occurred during untar.", 4056 "Message": "An error occurred during untar." 4057 } 4058 }, 4059 4060 { 4061 "Name": "xyz.openbmc_project.Software.Image.Error.ManifestFileFailure", 4062 "Subsystem": "bmc_firmware", 4063 "ComponentID": "0x3600", 4064 "SRC": 4065 { 4066 "ReasonCode": "0x3604", 4067 "Words6To9": 4068 { 4069 } 4070 }, 4071 4072 "Callouts": [ 4073 { 4074 "CalloutList": [ 4075 { "Priority": "high", "Procedure": "bmc_code" } 4076 ] 4077 } 4078 ], 4079 4080 "Documentation": 4081 { 4082 "Description": "An error when reading the Manifest file..", 4083 "Message": "An error when reading the Manifest file.." 4084 } 4085 }, 4086 4087 { 4088 "Name": "xyz.openbmc_project.Software.Image.Error.InternalFailure", 4089 "Subsystem": "bmc_firmware", 4090 "ComponentID": "0x3600", 4091 "SRC": 4092 { 4093 "ReasonCode": "0x3605", 4094 "Words6To9": 4095 { 4096 } 4097 }, 4098 4099 "Callouts": [ 4100 { 4101 "CalloutList": [ 4102 { "Priority": "high", "Procedure": "bmc_code" } 4103 ] 4104 } 4105 ], 4106 4107 "Documentation": 4108 { 4109 "Description": "The operation failed internally during processing the image.", 4110 "Message": "The operation failed internally during processing the image." 4111 } 4112 }, 4113 4114 { 4115 "Name": "xyz.openbmc_project.Software.Image.Error.ImageFailure", 4116 "Subsystem": "bmc_firmware", 4117 "ComponentID": "0x3600", 4118 "SRC": 4119 { 4120 "ReasonCode": "0x3606", 4121 "Words6To9": 4122 { 4123 } 4124 }, 4125 4126 "Callouts": [ 4127 { 4128 "CalloutList": [ 4129 { "Priority": "high", "Procedure": "bmc_code" } 4130 ] 4131 } 4132 ], 4133 4134 "Documentation": 4135 { 4136 "Description": "An error occurred processing the image.", 4137 "Message": "An error occurred processing the image." 4138 } 4139 }, 4140 4141 { 4142 "Name": "xyz.openbmc_project.Software.Image.Error.BusyFailure", 4143 "Subsystem": "bmc_firmware", 4144 "ComponentID": "0x3600", 4145 "SRC": 4146 { 4147 "ReasonCode": "0x3607", 4148 "Words6To9": 4149 { 4150 } 4151 }, 4152 4153 "Callouts": [ 4154 { 4155 "CalloutList": [ 4156 { "Priority": "high", "Procedure": "bmc_code" } 4157 ] 4158 } 4159 ], 4160 4161 "Documentation": 4162 { 4163 "Description": "The device is busy during the update.", 4164 "Message": "The device is busy during the update." 4165 } 4166 } 4167 4168 ] 4169} 4170