1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 8 "SRC": 9 { 10 "ReasonCode": "0x1001", 11 "Words6To9": 12 { 13 "6": 14 { 15 "Description": "Timeout in ms", 16 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 17 } 18 } 19 }, 20 21 "Documentation": 22 { 23 "Description": "This is a generic timeout error", 24 "Message": "An operation timed out", 25 "Notes": [ 26 "The journal should contain more information" 27 ] 28 } 29 }, 30 31 { 32 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 33 "Subsystem": "bmc_firmware", 34 35 "SRC": 36 { 37 "ReasonCode": "0x1002", 38 "Words6To9": 39 { 40 } 41 }, 42 43 "Documentation": 44 { 45 "Description": "BMC code had a generic internal failure", 46 "Message": "An application had an internal failure", 47 "Notes": [ 48 "The journal should contain more information" 49 ] 50 } 51 }, 52 53 { 54 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 55 "Subsystem": "user_error", 56 57 "SRC": 58 { 59 "ReasonCode": "0x1003", 60 "Words6To9": 61 { 62 } 63 }, 64 65 "Documentation": 66 { 67 "Description": "BMC code was given an invalid argument", 68 "Message": "Code was given an invalid argument", 69 "Notes": [ 70 "The journal should contain more information" 71 ] 72 } 73 }, 74 { 75 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 76 "Subsystem": "user_error", 77 78 "SRC": 79 { 80 "ReasonCode": "0x1004", 81 "Words6To9": 82 { 83 } 84 }, 85 86 "Documentation": 87 { 88 "Description": "An operation failed due to insufficient permission", 89 "Message": "An operation failed due to unsufficient permission", 90 "Notes": [ 91 "The journal should contain more information" 92 ] 93 } 94 }, 95 96 { 97 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 98 "Subsystem": "user_error", 99 100 "SRC": 101 { 102 "ReasonCode": "0x1005", 103 "Words6To9": 104 { 105 } 106 }, 107 108 "Documentation": 109 { 110 "Description": "An operation failed because it isn't allowed", 111 "Message": "An operation failed because it isn't allowed", 112 "Notes": [ 113 "The journal should contain more information" 114 ] 115 } 116 }, 117 118 { 119 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 120 "Subsystem": "user_error", 121 122 "SRC": 123 { 124 "ReasonCode": "0x1006", 125 "Words6To9": 126 { 127 } 128 }, 129 130 "Documentation": 131 { 132 "Description": "The server's CA certificate has not been provided", 133 "Message": "The server's CA certificate has not been provided" 134 } 135 }, 136 137 { 138 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 139 "Subsystem": "cec_chip_iface", 140 141 "SRC": 142 { 143 "ReasonCode": "0x1007", 144 "Words6To9": 145 { 146 "6": 147 { 148 "Description": "errno of the failure", 149 "AdditionalDataPropSource": "CALLOUT_ERRNO" 150 } 151 } 152 }, 153 154 "Documentation": 155 { 156 "Description": "Sensor device read failure", 157 "Message": "There was a failure when reading a sensor device", 158 "Notes": [ 159 "The severity is set by the creator.", 160 "The action flags are set automatically by the code.", 161 "Callouts added based on CALLOUT_DEVICE_PATH." 162 ] 163 } 164 }, 165 166 { 167 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 168 "Subsystem": "cec_chip_iface", 169 170 "SRC": 171 { 172 "ReasonCode": "0x1008", 173 "Words6To9": 174 { 175 "6": 176 { 177 "Description": "errno of the failure", 178 "AdditionalDataPropSource": "CALLOUT_ERRNO" 179 } 180 } 181 }, 182 183 "Documentation": 184 { 185 "Description": "Device read failure", 186 "Message": "There was a failure when reading a hardware device", 187 "Notes": [ 188 "The severity is set by the creator.", 189 "The action flags are set automatically by the code.", 190 "Callouts added based on CALLOUT_DEVICE_PATH." 191 ] 192 } 193 }, 194 195 { 196 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 197 "Subsystem": "cec_chip_iface", 198 199 "SRC": 200 { 201 "ReasonCode": "0x1009", 202 "Words6To9": 203 { 204 "6": 205 { 206 "Description": "errno of the failure", 207 "AdditionalDataPropSource": "CALLOUT_ERRNO" 208 } 209 } 210 }, 211 212 "Documentation": 213 { 214 "Description": "Device write failure", 215 "Message": "There was a failure when writing to a hardware device", 216 "Notes": [ 217 "The severity is set by the creator.", 218 "The action flags are set automatically by the code.", 219 "Callouts added based on CALLOUT_DEVICE_PATH" 220 ] 221 } 222 }, 223 224 { 225 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 226 "Subsystem": "cec_chip_iface", 227 228 "SRC": 229 { 230 "ReasonCode": "0x100A", 231 "Words6To9": 232 { 233 "6": 234 { 235 "Description": "errno of the failure", 236 "AdditionalDataPropSource": "CALLOUT_ERRNO" 237 } 238 } 239 }, 240 241 "Documentation": 242 { 243 "Description": "Device write failure", 244 "Message": "There was a failure when writing to a hardware device", 245 "Notes": [ 246 "The severity is set by the creator.", 247 "The action flags are set automatically by the code.", 248 "Callouts added based on CALLOUT_DEVICE_PATH" 249 ] 250 } 251 }, 252 253 { 254 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 255 "Subsystem": "bmc_firmware", 256 "Severity": "non_error", 257 258 "SRC": 259 { 260 "ReasonCode": "0x2001", 261 "Words6To9": 262 { 263 "6": 264 { 265 "Description": "The bad PEL ID", 266 "AdditionalDataPropSource": "BAD_ID" 267 } 268 } 269 }, 270 271 "Documentation": 272 { 273 "Description": "The BMC sent the host a malformed PEL", 274 "Message": "The BMC sent the host a malformed PEL", 275 "Notes": [ 276 "The host firmware rejected that PEL." 277 ] 278 } 279 }, 280 281 { 282 "Name": "org.open_power.Logging.Error.BadHostPEL", 283 "Subsystem": "platform_firmware", 284 "Severity": "unrecoverable", 285 286 "SRC": 287 { 288 "ReasonCode": "0x2002", 289 "Words6To9": 290 { 291 "6": 292 { 293 "Description": "The PLID of the invalid PEL", 294 "AdditionalDataPropSource": "PLID" 295 }, 296 "7": 297 { 298 "Description": "The corresponding OpenBMC event log ID", 299 "AdditionalDataPropSource": "OBMC_LOG_ID" 300 }, 301 "8": 302 { 303 "Description": "The size of the invalid PEL", 304 "AdditionalDataPropSource": "PEL_SIZE" 305 } 306 } 307 }, 308 309 "Documentation": 310 { 311 "Description": "The host sent the BMC an invalid PEL", 312 "Message": "The host sent the BMC an invalid PEL", 313 "Notes": [ 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.TestError1", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2003", 326 "Words6To9": 327 { 328 } 329 }, 330 331 "Callouts": [ 332 { 333 "CalloutList": [ 334 {"Priority": "high", "Procedure": "bmc_code"}, 335 {"Priority": "medium", "SymbolicFRU": "service_docs"} 336 ] 337 } 338 ], 339 340 "Documentation": 341 { 342 "Description": "An error for testing", 343 "Message": "This is a test error" 344 } 345 }, 346 347 { 348 "Name": "xyz.openbmc_project.Logging.Error.Default", 349 "Subsystem": "other_na", 350 351 "SRC": 352 { 353 "ReasonCode": "0x2004", 354 "Words6To9": 355 { 356 } 357 }, 358 359 "Documentation": 360 { 361 "Description": "This entry is used when no other matching entry is found", 362 "Message": "Unknown (Original event not in message registry)", 363 "Notes": [ 364 "This is used when the actual error name isn't found in ", 365 "the registry. The original error name will be stored ", 366 "in the UserData section that contains the AdditionalData ", 367 "properties using the key ERROR_NAME.", 368 "This error may contain callouts if the creator passed ", 369 "them in.", 370 "The severity is set by the creator.", 371 "If this error is seen, then a code change needs to be ", 372 "made to add the missing error entry to this registry." 373 ] 374 } 375 }, 376 377 { 378 "Name": "org.open_power.PHAL.Error.Boot", 379 "Subsystem": "cec_hardware", 380 "ComponentID": "0x3000", 381 "Severity": "unrecoverable", 382 383 "SRC": 384 { 385 "ReasonCode": "0x3001", 386 "Words6To9": 387 { 388 } 389 }, 390 391 "Documentation": 392 { 393 "Description": "Failure occured during boot process", 394 "Message": "Failure occured during boot process", 395 "Notes": [ 396 "Debug traces will be captured in AdditionalData section" 397 ] 398 } 399 }, 400 401 { 402 "Name": "org.open_power.PHAL.Error.PrePowerOff", 403 "Subsystem": "cec_hardware", 404 "ComponentID": "0x3000", 405 406 "SRC": 407 { 408 "ReasonCode": "0x3002", 409 "Words6To9": 410 { 411 } 412 }, 413 414 "Documentation": 415 { 416 "Description": "Failure occurred during PHAL pre-poweroff operations", 417 "Message": "Failure occurred during PHAL pre-poweroff operations", 418 "Notes": [ 419 "Severity needs to be set based on needs for this registry.", 420 "FFDC (First Failure Data Collection) will be collected ", 421 "and added into PEL." 422 ] 423 } 424 }, 425 426 { 427 "Name": "org.open_power.PHAL.Error.devtreeSync", 428 "Subsystem": "cec_hardware", 429 "ComponentID": "0x3000", 430 "Severity": "unrecoverable", 431 432 "SRC": 433 { 434 "ReasonCode": "0x3003", 435 "Words6To9": 436 { 437 } 438 }, 439 440 "Documentation": 441 { 442 "Description": "Failure occurred during PHAL devtree sync ", 443 "Message": "Failure occurred during PHAL devtree sync", 444 "Notes": [ 445 "The journal should contain more information" 446 ] 447 } 448 }, 449 450 { 451 "Name": "org.open_power.PHAL.Error.devtreeBackup", 452 "Subsystem": "cec_hardware", 453 "ComponentID": "0x3000", 454 "Severity": "unrecoverable", 455 456 "SRC": 457 { 458 "ReasonCode": "0x3004", 459 "Words6To9": 460 { 461 } 462 }, 463 464 "Documentation": 465 { 466 "Description": "Failure occurred during PHAL devtree backup ", 467 "Message": "Failure occurred during PHAL devtree backup", 468 "Notes": [ 469 "The journal should contain more information" 470 ] 471 } 472 }, 473 474 { 475 "Name": "org.open_power.PHAL.Error.HostRunning", 476 "Subsystem": "cec_sp_hostboot_iface", 477 "ComponentID": "0x3000", 478 479 "SRC": 480 { 481 "ReasonCode": "0x3005", 482 "Words6To9": 483 { 484 } 485 }, 486 487 "Documentation": 488 { 489 "Description": "Host did not respond to BMC after a BMC reset", 490 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 491 "Notes": [ 492 "System will be left in its current state to ensure host ", 493 "is not unexpectedly taken down. There is most likely an ", 494 "issue in the software or hardware communication path ", 495 "between the BMC and the Host firmware.", 496 "A BMC dump will be collected with relevant FFDC." 497 ] 498 } 499 }, 500 501 { 502 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 503 "Subsystem": "processor_chip", 504 "ComponentID": "0x3500", 505 506 "SRC": 507 { 508 "ReasonCode": "0x3500", 509 "Words6To9": 510 { 511 "6": 512 { 513 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 514 "AdditionalDataPropSource": "SRC6" 515 } 516 } 517 }, 518 519 "Documentation": 520 { 521 "Description": "chipop failure with SBE provided FFDC", 522 "Message": "chipop request failure reported by SBE", 523 "Notes": [ 524 "The severity is set by the creator.", 525 "Callouts added based on SBE provided FFDC.", 526 "SBE provided additional debug data included as part of the", 527 "additional user data section." 528 ] 529 } 530 }, 531 532 { 533 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 534 "Subsystem": "processor_chip", 535 "ComponentID": "0x3500", 536 537 "SRC": 538 { 539 "ReasonCode": "0x3501", 540 "Words6To9": 541 { 542 "6": 543 { 544 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 545 "AdditionalDataPropSource": "SRC6" 546 } 547 } 548 }, 549 550 "Documentation": 551 { 552 "Description": "SBE chipop timeout", 553 "Message": "chipop timeout reported during SBE communication", 554 "Notes": [ 555 "The severity is set by the creator.", 556 "Check SBE Dump associated to this error to debug the failure." 557 ] 558 } 559 }, 560 561 { 562 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 563 "Subsystem": "processor_chip", 564 "ComponentID": "0x3500", 565 566 "SRC": 567 { 568 "ReasonCode": "0x3502", 569 "Words6To9": 570 { 571 "6": 572 { 573 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 574 "AdditionalDataPropSource": "SRC6" 575 }, 576 "7": 577 { 578 "Description": "Value of SBE state", 579 "AdditionalDataPropSource": "SRC7" 580 } 581 } 582 }, 583 584 "Documentation": 585 { 586 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 587 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 588 "Notes": [ 589 "The severity is set by the creator." 590 ] 591 } 592 }, 593 594 { 595 "Name": "org.open_power.Attn.Error.Terminate", 596 "Subsystem": "cec_hardware", 597 "Severity": "non_error", 598 599 "SRC": 600 { 601 "ReasonCode": "0xD138", 602 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 603 "Words6To9": 604 { 605 } 606 }, 607 608 "Documentation": 609 { 610 "Description": "Status shows TI special attention active", 611 "Message": "TI special attention detected", 612 "Notes": [ 613 "This entry is for any TI special attention event ", 614 "reported by the attention handler component" 615 ] 616 } 617 }, 618 619 { 620 "Name": "org.open_power.Attn.Error.Fail", 621 "Subsystem": "bmc_firmware", 622 "Severity": "unrecoverable_loss_of_function", 623 624 "SRC": 625 { 626 "ReasonCode": "0xD13E", 627 "Words6To9": 628 { 629 "6": 630 { 631 "Description": "Error code from attention handler", 632 "AdditionalDataPropSource": "ERROR_CODE" 633 } 634 } 635 }, 636 "Documentation": 637 { 638 "Description": "The attention handler encountered an error", 639 "MessageArgSources" : ["SRCWord6"], 640 "Message": "Attention handler error %1", 641 "Notes": [ 642 "Attention handler will provide error code" 643 ] 644 } 645 }, 646 647 { 648 "Name": "org.open_power.Attn.Error.Vital", 649 "Subsystem": "processor_chip", 650 "Severity": "critical", 651 652 "SRC": 653 { 654 "ReasonCode": "0xD16D", 655 "Words6To9": 656 { 657 } 658 }, 659 660 "Documentation": 661 { 662 "Description": "Status shows SBE vital attention active", 663 "Message": "SBE vital attention detected", 664 "Notes": [ 665 "This entry is for any SBE vital attention event ", 666 "reported by the attention handler component" 667 ] 668 } 669 }, 670 671 { 672 "Name": "org.open_power.HwDiags.Error.Checkstop", 673 "Subsystem": "cec_hardware", 674 "ActionFlags": [ "service_action", "report", "call_home" ], 675 676 "SRC": 677 { 678 "ReasonCode": "0xE510", 679 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 680 "Words6To9": 681 { 682 } 683 }, 684 685 "Documentation": 686 { 687 "Description": "A system checkstop attention has occurred", 688 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 689 "Message": "hw-diags signature: %1 %2 %3" 690 } 691 }, 692 693 { 694 "Name": "org.open_power.HwDiags.Error.Predictive", 695 "Subsystem": "cec_hardware", 696 "ActionFlags": [ "service_action", "report", "call_home" ], 697 698 "SRC": 699 { 700 "ReasonCode": "0xE511", 701 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 702 "Words6To9": 703 { 704 } 705 }, 706 707 "Documentation": 708 { 709 "Description": "A hardware attention requiring service has occurred", 710 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 711 "Message": "hw-diags signature: %1 %2 %3" 712 } 713 }, 714 715 { 716 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 717 "Subsystem": "power_supply", 718 "Severity": "unrecoverable_redundancy_loss", 719 "ActionFlags": ["service_action", "report"], 720 "ComponentID": "0x2700", 721 722 "SRC": { 723 "Type": "11", 724 "ReasonCode": "0x15F0", 725 "Words6To9": {} 726 }, 727 728 "Callouts": [ 729 { 730 "CalloutList": [ 731 { "Priority": "high", "SymbolicFRU": "pwrsply" } 732 ] 733 } 734 ], 735 736 "Documentation": { 737 "Description": "Power Supply input power fault", 738 "Message": "A power supply has indicated an input or under voltage condition.", 739 "Notes": [ 740 "Check the power supply cabling and/or input power ", 741 "source. The PWRSPLY procedure is used rather than ", 742 "calling out a location code, as typically these faults ", 743 "are related to the supplied power, the cable, or the ", 744 "cable connectors. If the input fault resolves down to an ", 745 "issue with the power supply itself, the power supply ", 746 "indicating this input fault should be called out. Add the ", 747 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 748 "CALLOUT_PRIORITY to something other than high." 749 ] 750 } 751 }, 752 753 { 754 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 755 "Subsystem": "power_supply", 756 "Severity": "unrecoverable_redundancy_loss", 757 "ActionFlags": ["service_action", "report", "call_home"], 758 "ComponentID": "0x2700", 759 760 "SRC": { 761 "Type": "11", 762 "ReasonCode": "0x15F1", 763 "Words6To9": {} 764 }, 765 766 "Documentation": { 767 "Description": "Power Supply power fault", 768 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 769 "Notes": [ 770 "The power supply reporting the fault should be called ", 771 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 772 "specific fault, STATUS_* details, and code level in the ", 773 "AdditionalData section." 774 ] 775 } 776 }, 777 778 { 779 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 780 "Subsystem": "power_supply", 781 "Severity": "unrecoverable", 782 "ActionFlags": ["service_action", "report", "call_home"], 783 "ComponentID": "0x2700", 784 785 "SRC": { 786 "Type": "11", 787 "ReasonCode": "0x15F2", 788 "Words6To9": {} 789 }, 790 791 "Documentation": { 792 "Description": "Power Supply non-power fault", 793 "Message": "A communication failure occurred talking to the power supply", 794 "Notes": [ 795 "Communication problems with the power supply could be ", 796 "the power supply, or any hardware between it and the ", 797 "BMC. Reporting the error should be passing in a call ", 798 "out using CALLOUT_DEVICE_PATH." 799 ] 800 } 801 }, 802 803 { 804 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 805 "Subsystem": "power_supply", 806 "Severity": "unrecoverable_redundancy_loss", 807 "ActionFlags": ["service_action", "report", "call_home"], 808 "ComponentID": "0x2700", 809 810 "SRC": { 811 "Type": "11", 812 "ReasonCode": "0x15F6", 813 "Words6To9": {} 814 }, 815 816 "Callouts": [ 817 { 818 "CalloutList": [ 819 { 820 "Priority": "high", 821 "SymbolicFRUTrusted": "pwrsply", 822 "UseInventoryLocCode": true 823 } 824 ] 825 } 826 ], 827 828 "Documentation": { 829 "Description": "Power Supply is missing", 830 "Message": "A power supply that should be present is missing", 831 "Notes": [ 832 "The CalloutList should use the PWRSPLY symbolic FRU ", 833 "with the trusted location code property. The ", 834 "location code in this callout is obtained from ", 835 "the passed in CALLOUT_INVENTORY_PATH value." 836 ] 837 } 838 }, 839 840 { 841 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 842 "Subsystem": "power_supply", 843 "Severity": "unrecoverable", 844 "ActionFlags": ["service_action", "report", "call_home"], 845 "ComponentID": "0x2700", 846 847 "SRC": { 848 "Type": "11", 849 "ReasonCode": "0x15F7", 850 "Words6To9": {} 851 }, 852 853 "Documentation": { 854 "Description": "Power Supply configuration is not supported", 855 "Message": "The power supply configuration is not supported", 856 "Notes": [ 857 "The combination of power supplies detected in the ", 858 "system is not supported. This could be caused by ", 859 "mismatched models, less than expected number of power ", 860 "supplies, or other unsupported characteristics." 861 ] 862 } 863 }, 864 865 { 866 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 867 "Subsystem": "power", 868 "ActionFlags": [ "report", "service_action" ], 869 "Severity": "unrecoverable", 870 "ComponentID": "0x2700", 871 872 "SRC": 873 { 874 "Type": "11", 875 "ReasonCode": "0x00AC", 876 "Words6To9": {}, 877 "PowerFault": true 878 }, 879 880 "Callouts": [ 881 { 882 "CalloutList": [ 883 { "Priority": "high", "SymbolicFRU": "ac_module"} 884 ] 885 } 886 ], 887 888 "Documentation": { 889 "Description": "Input power was lost while the system was powered on.", 890 "Message": "Input power was lost while the system was powered on.", 891 "Notes": [ 892 "Input power was lost while system powered on.", 893 "The CalloutList should use the ACMODUL symbolic FRU." 894 ] 895 } 896 }, 897 898 { 899 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 900 "Subsystem": "power_sequencer", 901 "ComponentID": "0x2700", 902 903 "SRC": { 904 "Type": "11", 905 "ReasonCode": "0x2600", 906 "Words6To9": {} 907 }, 908 909 "Callouts": [ 910 { 911 "CalloutList": [ 912 { "Priority": "high", "SymbolicFRU": "pgood_part" } 913 ] 914 } 915 ], 916 917 "Documentation": { 918 "Description": "A power off was issued because a power fault was detected", 919 "Message": "A power off was issued because a power fault was detected", 920 "Notes": [ 921 ] 922 } 923 }, 924 925 { 926 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 927 "Subsystem": "power_sequencer", 928 "ComponentID": "0x2700", 929 930 "SRC": { 931 "Type": "11", 932 "ReasonCode": "0x2610", 933 "Words6To9": {} 934 }, 935 936 "CalloutsUsingAD": { 937 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 938 { 939 "ADValue": "PCIE_SLOT0", "Callouts": [ 940 { 941 "CalloutList": [ 942 { "Priority": "high", "LocCode": "P0-C0" }, 943 { "Priority": "medium", "LocCode": "P0" } 944 ] 945 } 946 ] 947 }, 948 { 949 "ADValue": "PCIE_SLOT1", "Callouts": [ 950 { 951 "CalloutList": [ 952 { "Priority": "high", "LocCode": "P0-C1" }, 953 { "Priority": "medium", "LocCode": "P0" } 954 ] 955 } 956 ] 957 }, 958 { 959 "ADValue": "PCIE_SLOT2", "Callouts": [ 960 { 961 "CalloutList": [ 962 { "Priority": "high", "LocCode": "P0-C2" }, 963 { "Priority": "medium", "LocCode": "P0" } 964 ] 965 } 966 ] 967 }, 968 { 969 "ADValue": "PCIE_SLOT3", "Callouts": [ 970 { 971 "CalloutList": [ 972 { "Priority": "high", "LocCode": "P0-C3" }, 973 { "Priority": "medium", "LocCode": "P0" } 974 ] 975 } 976 ] 977 }, 978 { 979 "ADValue": "PCIE_SLOT4", "Callouts": [ 980 { 981 "CalloutList": [ 982 { "Priority": "high", "LocCode": "P0-C4" }, 983 { "Priority": "medium", "LocCode": "P0" } 984 ] 985 } 986 ] 987 }, 988 { 989 "ADValue": "PCIE_SLOT7", "Callouts": [ 990 { 991 "CalloutList": [ 992 { "Priority": "high", "LocCode": "P0-C7" }, 993 { "Priority": "medium", "LocCode": "P0" } 994 ] 995 } 996 ] 997 }, 998 { 999 "ADValue": "PCIE_SLOT8", "Callouts": [ 1000 { 1001 "CalloutList": [ 1002 { "Priority": "high", "LocCode": "P0-C8" }, 1003 { "Priority": "medium", "LocCode": "P0" } 1004 ] 1005 } 1006 ] 1007 }, 1008 { 1009 "ADValue": "PCIE_SLOT9", "Callouts": [ 1010 { 1011 "CalloutList": [ 1012 { "Priority": "high", "LocCode": "P0-C9" }, 1013 { "Priority": "medium", "LocCode": "P0" } 1014 ] 1015 } 1016 ] 1017 }, 1018 { 1019 "ADValue": "PCIE_SLOT10", "Callouts": [ 1020 { 1021 "CalloutList": [ 1022 { "Priority": "high", "LocCode": "P0-C10" }, 1023 { "Priority": "medium", "LocCode": "P0" } 1024 ] 1025 } 1026 ] 1027 }, 1028 { 1029 "ADValue": "PCIE_SLOT11", "Callouts": [ 1030 { 1031 "CalloutList": [ 1032 { "Priority": "high", "LocCode": "P0-C11" }, 1033 { "Priority": "medium", "LocCode": "P0" } 1034 ] 1035 } 1036 ] 1037 }, 1038 { 1039 "ADValue": "PGOOD_12A", "Callouts": [ 1040 { 1041 "CalloutList": [ 1042 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1043 ] 1044 } 1045 ] 1046 }, 1047 { 1048 "ADValue": "PGOOD_12B", "Callouts": [ 1049 { 1050 "CalloutList": [ 1051 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1052 ] 1053 } 1054 ] 1055 }, 1056 { 1057 "ADValue": "PGOOD_12C", "Callouts": [ 1058 { 1059 "CalloutList": [ 1060 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1061 ] 1062 } 1063 ] 1064 }, 1065 { 1066 "ADValue": "PGOOD_12D", "Callouts": [ 1067 { 1068 "CalloutList": [ 1069 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1070 ] 1071 } 1072 ] 1073 }, 1074 { 1075 "ADValue": "PGOOD_12L", "Callouts": [ 1076 { 1077 "CalloutList": [ 1078 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1079 ] 1080 } 1081 ] 1082 }, 1083 { 1084 "ADValue": "PGOOD_12M", "Callouts": [ 1085 { 1086 "CalloutList": [ 1087 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1088 ] 1089 } 1090 ] 1091 }, 1092 { 1093 "ADValue": "PGOOD_12N", "Callouts": [ 1094 { 1095 "CalloutList": [ 1096 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1097 ] 1098 } 1099 ] 1100 }, 1101 { 1102 "ADValue": "PGOOD_12P", "Callouts": [ 1103 { 1104 "CalloutList": [ 1105 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1106 ] 1107 } 1108 ] 1109 }, 1110 { 1111 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1112 { 1113 "CalloutList": [ 1114 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1115 ] 1116 } 1117 ] 1118 }, 1119 { 1120 "ADValue": "PGOOD_12Q", "Callouts": [ 1121 { 1122 "CalloutList": [ 1123 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1124 ] 1125 } 1126 ] 1127 }, 1128 { 1129 "ADValue": "PGOOD_12R", "Callouts": [ 1130 { 1131 "CalloutList": [ 1132 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1133 ] 1134 } 1135 ] 1136 }, 1137 { 1138 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1139 { 1140 "CalloutList": [ 1141 { "Priority": "high", "LocCode": "P0-C14" }, 1142 { "Priority": "medium", "LocCode": "P0-C15" }, 1143 { "Priority": "low", "LocCode": "P0" } 1144 ] 1145 } 1146 ] 1147 }, 1148 { 1149 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1150 { 1151 "CalloutList": [ 1152 { "Priority": "high", "LocCode": "P0-C23" }, 1153 { "Priority": "medium", "LocCode": "P0-C24" }, 1154 { "Priority": "low", "LocCode": "P0" } 1155 ] 1156 } 1157 ] 1158 }, 1159 { 1160 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1161 { 1162 "CalloutList": [ 1163 { "Priority": "high", "LocCode": "P0-C14" }, 1164 { "Priority": "medium", "LocCode": "P0-C15" }, 1165 { "Priority": "low", "LocCode": "P0" } 1166 ] 1167 } 1168 ] 1169 }, 1170 { 1171 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1172 { 1173 "CalloutList": [ 1174 { "Priority": "high", "LocCode": "P0-C23" }, 1175 { "Priority": "medium", "LocCode": "P0-C24" }, 1176 { "Priority": "low", "LocCode": "P0" } 1177 ] 1178 } 1179 ] 1180 }, 1181 { 1182 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1183 { 1184 "CalloutList": [ 1185 { "Priority": "high", "LocCode": "P0-C14" }, 1186 { "Priority": "medium", "LocCode": "P0-C15" }, 1187 { "Priority": "low", "LocCode": "P0" } 1188 ] 1189 } 1190 ] 1191 }, 1192 { 1193 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1194 { 1195 "CalloutList": [ 1196 { "Priority": "high", "LocCode": "P0-C23" }, 1197 { "Priority": "medium", "LocCode": "P0-C24" }, 1198 { "Priority": "low", "LocCode": "P0" } 1199 ] 1200 } 1201 ] 1202 }, 1203 { 1204 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1205 { 1206 "CalloutList": [ 1207 { "Priority": "high", "LocCode": "P0-C14" }, 1208 { "Priority": "medium", "LocCode": "P0-C15" }, 1209 { "Priority": "low", "LocCode": "P0" } 1210 ] 1211 } 1212 ] 1213 }, 1214 { 1215 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1216 { 1217 "CalloutList": [ 1218 { "Priority": "high", "LocCode": "P0-C23" }, 1219 { "Priority": "medium", "LocCode": "P0-C24" }, 1220 { "Priority": "low", "LocCode": "P0" } 1221 ] 1222 } 1223 ] 1224 } 1225 ] 1226 }, 1227 1228 "Documentation": { 1229 "Description": "The power sequencer chip detected a PGOOD fault", 1230 "Message": "The power sequencer chip detected a PGOOD fault", 1231 "Notes": [ 1232 ] 1233 } 1234 }, 1235 1236 { 1237 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 1238 "Subsystem": "power_sequencer", 1239 "ComponentID": "0x2700", 1240 1241 "SRC": { 1242 "Type": "11", 1243 "ReasonCode": "0x2620", 1244 "Words6To9": {} 1245 }, 1246 1247 "CalloutsUsingAD": { 1248 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 1249 { 1250 "ADValue": "12.0V", "Callouts": [ 1251 { 1252 "CalloutList": [ 1253 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1254 ] 1255 } 1256 ] 1257 }, 1258 { 1259 "ADValue": "5.0V_USB", "Callouts": [ 1260 { 1261 "CalloutList": [ 1262 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1263 { "Priority": "medium", "LocCode": "P0" } 1264 ] 1265 } 1266 ] 1267 }, 1268 { 1269 "ADValue": "5.0V_DASD", "Callouts": [ 1270 { 1271 "CalloutList": [ 1272 { "Priority": "medium", "LocCode": "P1" }, 1273 { "Priority": "medium", "LocCode": "P2" }, 1274 { "Priority": "medium", "LocCode": "P3" }, 1275 { "Priority": "low", "LocCode": "P0" } 1276 ] 1277 } 1278 ] 1279 }, 1280 { 1281 "ADValue": "3.3VA", "Callouts": [ 1282 { 1283 "CalloutList": [ 1284 { "Priority": "high", "LocCode": "P0" } 1285 ] 1286 } 1287 ] 1288 }, 1289 { 1290 "ADValue": "3.3VB", "Callouts": [ 1291 { 1292 "CalloutList": [ 1293 { "Priority": "high", "LocCode": "P0" } 1294 ] 1295 } 1296 ] 1297 }, 1298 { 1299 "ADValue": "1.5V", "Callouts": [ 1300 { 1301 "CalloutList": [ 1302 { "Priority": "high", "LocCode": "P0" } 1303 ] 1304 } 1305 ] 1306 }, 1307 { 1308 "ADValue": "1.1V", "Callouts": [ 1309 { 1310 "CalloutList": [ 1311 { "Priority": "high", "LocCode": "P0" } 1312 ] 1313 } 1314 ] 1315 }, 1316 { 1317 "ADValue": "VDDA_DCM0", "Callouts": [ 1318 { 1319 "CalloutList": [ 1320 { "Priority": "high", "LocCode": "P0-C14" }, 1321 { "Priority": "medium", "LocCode": "P0-C15" }, 1322 { "Priority": "low", "LocCode": "P0" } 1323 ] 1324 } 1325 ] 1326 }, 1327 { 1328 "ADValue": "VDDB_DCM0", "Callouts": [ 1329 { 1330 "CalloutList": [ 1331 { "Priority": "high", "LocCode": "P0-C14" }, 1332 { "Priority": "medium", "LocCode": "P0-C15" }, 1333 { "Priority": "low", "LocCode": "P0" } 1334 ] 1335 } 1336 ] 1337 }, 1338 { 1339 "ADValue": "VDDA_DCM1", "Callouts": [ 1340 { 1341 "CalloutList": [ 1342 { "Priority": "high", "LocCode": "P0-C23" }, 1343 { "Priority": "medium", "LocCode": "P0-C24" }, 1344 { "Priority": "low", "LocCode": "P0" } 1345 ] 1346 } 1347 ] 1348 }, 1349 { 1350 "ADValue": "VDDB_DCM1", "Callouts": [ 1351 { 1352 "CalloutList": [ 1353 { "Priority": "high", "LocCode": "P0-C23" }, 1354 { "Priority": "medium", "LocCode": "P0-C24" }, 1355 { "Priority": "low", "LocCode": "P0" } 1356 ] 1357 } 1358 ] 1359 }, 1360 { 1361 "ADValue": "12.0VCS", "Callouts": [ 1362 { 1363 "CalloutList": [ 1364 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1365 ] 1366 } 1367 ] 1368 }, 1369 { 1370 "ADValue": "3.3VCS", "Callouts": [ 1371 { 1372 "CalloutList": [ 1373 { "Priority": "high", "LocCode": "P0" } 1374 ] 1375 } 1376 ] 1377 }, 1378 { 1379 "ADValue": "1.1V_Current", "Callouts": [ 1380 { 1381 "CalloutList": [ 1382 { "Priority": "high", "LocCode": "P0" } 1383 ] 1384 } 1385 ] 1386 }, 1387 { 1388 "ADValue": "5.0V_USB_Current", "Callouts": [ 1389 { 1390 "CalloutList": [ 1391 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1392 { "Priority": "medium", "LocCode": "P0" } 1393 ] 1394 } 1395 ] 1396 }, 1397 { 1398 "ADValue": "5.0V_DASD_Current", "Callouts": [ 1399 { 1400 "CalloutList": [ 1401 { "Priority": "medium", "LocCode": "P1" }, 1402 { "Priority": "medium", "LocCode": "P2" }, 1403 { "Priority": "medium", "LocCode": "P3" }, 1404 { "Priority": "low", "LocCode": "P0" } 1405 ] 1406 } 1407 ] 1408 }, 1409 { 1410 "ADValue": "12.0VN", "Callouts": [ 1411 { 1412 "CalloutList": [ 1413 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1414 ] 1415 } 1416 ] 1417 }, 1418 { 1419 "ADValue": "12.0VP", "Callouts": [ 1420 { 1421 "CalloutList": [ 1422 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1423 ] 1424 } 1425 ] 1426 }, 1427 { 1428 "ADValue": "12.0VQ", "Callouts": [ 1429 { 1430 "CalloutList": [ 1431 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1432 ] 1433 } 1434 ] 1435 }, 1436 { 1437 "ADValue": "12.0VR", "Callouts": [ 1438 { 1439 "CalloutList": [ 1440 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1441 ] 1442 } 1443 ] 1444 }, 1445 { 1446 "ADValue": "ThermalDiode1", "Callouts": [ 1447 { 1448 "CalloutList": [ 1449 { "Priority": "high", "LocCode": "P0" } 1450 ] 1451 } 1452 ] 1453 }, 1454 { 1455 "ADValue": "ThermalDiode2", "Callouts": [ 1456 { 1457 "CalloutList": [ 1458 { "Priority": "high", "LocCode": "P0" } 1459 ] 1460 } 1461 ] 1462 }, 1463 { 1464 "ADValue": "ThermalDiode3", "Callouts": [ 1465 { 1466 "CalloutList": [ 1467 { "Priority": "high", "LocCode": "P0" } 1468 ] 1469 } 1470 ] 1471 }, 1472 { 1473 "ADValue": "ThermalDiode4", "Callouts": [ 1474 { 1475 "CalloutList": [ 1476 { "Priority": "high", "LocCode": "P0" } 1477 ] 1478 } 1479 ] 1480 } 1481 ] 1482 }, 1483 1484 "Documentation": { 1485 "Description": "The power sequencer chip detected a voltage fault", 1486 "Message": "The power sequencer chip detected a voltage fault", 1487 "Notes": [ 1488 ] 1489 } 1490 }, 1491 1492 { 1493 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 1494 "Subsystem": "power", 1495 "Severity": "predictive_redundancy_loss", 1496 "ComponentID": "0x2700", 1497 1498 "SRC": { 1499 "Type": "11", 1500 "ReasonCode": "0x2700", 1501 "Words6To9": {} 1502 }, 1503 1504 "Documentation": { 1505 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1506 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1507 "Notes": [ 1508 "CALLOUT_INVENTORY_PATH should be specified in the ", 1509 "AdditionalData property of the event log so that ", 1510 "the device is called out but not the communication path." 1511 ] 1512 } 1513 }, 1514 1515 { 1516 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 1517 "Subsystem": "power", 1518 "Severity": "non_error", 1519 "MfgSeverity": "predictive_redundancy_loss", 1520 "ActionFlags": ["report"], 1521 "MfgActionFlags": ["service_action", "report", "call_home"], 1522 "ComponentID": "0x2700", 1523 1524 "SRC": { 1525 "Type": "11", 1526 "ReasonCode": "0x2701", 1527 "Words6To9": {} 1528 }, 1529 1530 "Documentation": { 1531 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1532 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1533 "Notes": [ 1534 "CALLOUT_INVENTORY_PATH should be specified in the ", 1535 "AdditionalData property of the event log so that ", 1536 "the device is called out but not the communication path." 1537 ] 1538 } 1539 }, 1540 1541 { 1542 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 1543 "Subsystem": "power", 1544 "ComponentID": "0x2700", 1545 1546 "SRC": { 1547 "Type": "11", 1548 "ReasonCode": "0x2900", 1549 "Words6To9": {} 1550 }, 1551 1552 "Documentation": { 1553 "Description": "A write verification error occurred on a device", 1554 "Message": "A write verification error occurred on a device", 1555 "Notes": [ 1556 "This error occurs when a device register is written, ", 1557 "read back, and the two values do not match. This is ", 1558 "also called a read-back error. The device should be ", 1559 "identified using the CALLOUT_DEVICE_PATH or ", 1560 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 1561 "AdditionalData property of the event log. This will ", 1562 "cause the device and the hardware in the communication ", 1563 "path to be called out." 1564 ] 1565 } 1566 }, 1567 1568 { 1569 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 1570 "Subsystem": "power", 1571 "ComponentID": "0x2700", 1572 1573 "SRC": { 1574 "Type": "11", 1575 "ReasonCode": "0xA013", 1576 "Words6To9": {} 1577 }, 1578 1579 "Callouts": [ 1580 { 1581 "CalloutList": [ 1582 { "Priority": "high", "Procedure": "bmc_code" } 1583 ] 1584 } 1585 ], 1586 1587 "Documentation": { 1588 "Description": "A regulators configuration file error occurred", 1589 "Message": "A regulators configuration file error occurred", 1590 "Notes": [ 1591 "The regulators configuration file could not be found, ", 1592 "could not be read, or had invalid contents." 1593 ] 1594 } 1595 }, 1596 1597 { 1598 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 1599 "Subsystem": "power", 1600 "Severity": "critical_system_term", 1601 "ComponentID": "0x2700", 1602 1603 "SRC": { 1604 "Type": "11", 1605 "ReasonCode": "0xA014", 1606 "Words6To9": {}, 1607 "PowerFault": true 1608 }, 1609 1610 "Callouts": [ 1611 { 1612 "CalloutList": [ 1613 { "Priority": "high", "Procedure": "bmc_code" } 1614 ] 1615 } 1616 ], 1617 1618 "Documentation": { 1619 "Description": "A critical regulators configuration file error occurred", 1620 "Message": "A critical regulators configuration file error occurred", 1621 "Notes": [ 1622 "The regulators configuration file could not be found, ", 1623 "could not be read, or had invalid contents. As a result ", 1624 "voltage regulators could not be configured, and the ", 1625 "chassis could not be powered on." 1626 ] 1627 } 1628 }, 1629 1630 { 1631 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 1632 "Subsystem": "power_sequencer", 1633 "ComponentID": "0x2700", 1634 1635 "SRC": { 1636 "Type": "11", 1637 "ReasonCode": "0xD000", 1638 "Words6To9": {} 1639 }, 1640 1641 "Callouts": [ 1642 { 1643 "CalloutList": [ 1644 { "Priority": "high", "LocCode": "P0" } 1645 ] 1646 } 1647 ], 1648 1649 "Documentation": { 1650 "Description": "The power sequencer chip detected a fault", 1651 "Message": "The power sequencer chip detected a fault", 1652 "Notes": [ 1653 ] 1654 } 1655 }, 1656 1657 { 1658 "Name": "xyz.openbmc_project.Power.Error.PowerOnFailure", 1659 "Subsystem": "power_sequencer", 1660 "ComponentID": "0x2700", 1661 1662 "SRC": { 1663 "Type": "11", 1664 "ReasonCode": "0xD002", 1665 "Words6To9": {} 1666 }, 1667 1668 "Callouts": [ 1669 { 1670 "CalloutList": [ 1671 { "Priority": "high", "LocCode": "P0" } 1672 ] 1673 } 1674 ], 1675 1676 "Documentation": { 1677 "Description": "System power failed to turn on", 1678 "Message": "System power failed to turn on", 1679 "Notes": [ 1680 ] 1681 } 1682 }, 1683 1684 { 1685 "Name": "xyz.openbmc_project.Power.Error.Internal", 1686 "Subsystem": "power", 1687 "ComponentID": "0x2700", 1688 1689 "SRC": { 1690 "Type": "11", 1691 "ReasonCode": "0xE000", 1692 "Words6To9": {} 1693 }, 1694 1695 "Callouts": [ 1696 { 1697 "CalloutList": [ 1698 { "Priority": "high", "Procedure": "bmc_code" } 1699 ] 1700 } 1701 ], 1702 1703 "Documentation": { 1704 "Description": "An internal firmware error occurred", 1705 "Message": "An internal firmware error occurred", 1706 "Notes": [ 1707 "The error details must be provided in the AdditionalData ", 1708 "property of the event log." 1709 ] 1710 } 1711 }, 1712 1713 { 1714 "Name": "xyz.openbmc_project.Power.Error.I2C", 1715 "Subsystem": "cec_i2c", 1716 "ComponentID": "0x2700", 1717 1718 "SRC": { 1719 "Type": "11", 1720 "ReasonCode": "0xE100", 1721 "Words6To9": {} 1722 }, 1723 1724 "Documentation": { 1725 "Description": "An I2C error occurred communicating with a device", 1726 "Message": "An I2C error occurred communicating with a device", 1727 "Notes": [ 1728 "The device should be identified using the ", 1729 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 1730 "keywords in the AdditionalData property of the event ", 1731 "log. This will cause the device and the hardware in the ", 1732 "communication path to be called out." 1733 ] 1734 } 1735 }, 1736 1737 { 1738 "Name": "xyz.openbmc_project.Power.Error.PMBus", 1739 "Subsystem": "power", 1740 "ComponentID": "0x2700", 1741 1742 "SRC": { 1743 "Type": "11", 1744 "ReasonCode": "0xE200", 1745 "Words6To9": {} 1746 }, 1747 1748 "Documentation": { 1749 "Description": "A PMBus error occurred on a device", 1750 "Message": "A PMBus error occurred on a device", 1751 "Notes": [ 1752 "This error occurs when the I2C communication was ", 1753 "successful, but the PMBus value read is invalid or ", 1754 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 1755 "in the AdditionalData property of the event log so that ", 1756 "the device is called out but not the communication path." 1757 ] 1758 } 1759 }, 1760 1761 { 1762 "Name": "xyz.openbmc_project.Power.Error.DBus", 1763 "Subsystem": "power", 1764 "ComponentID": "0x2700", 1765 1766 "SRC": { 1767 "Type": "11", 1768 "ReasonCode": "0xE300", 1769 "Words6To9": {} 1770 }, 1771 1772 "Callouts": [ 1773 { 1774 "CalloutList": [ 1775 { "Priority": "high", "Procedure": "bmc_code" } 1776 ] 1777 } 1778 ], 1779 1780 "Documentation": { 1781 "Description": "A firmware inter-process communication (D-Bus) error occurred", 1782 "Message": "A firmware inter-process communication (D-Bus) error occurred" 1783 } 1784 }, 1785 1786 { 1787 "Name": "xyz.openbmc_project.Fan.Error.Fault", 1788 "Subsystem": "power_fans", 1789 "ComponentID": "0x2800", 1790 1791 "SRC": { 1792 "Type": "11", 1793 "ReasonCode": "0x76F0", 1794 "Words6To9": {} 1795 }, 1796 1797 "Documentation": { 1798 "Description": "Fan rotor fault", 1799 "Message": "Fan rotor fault", 1800 "Notes": [ 1801 "This error occurs when a fan rotor has been faulted for a ", 1802 "certain amount of time. The callout is the fan which is ", 1803 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 1804 "passed in during creation and will be either informational ", 1805 "or unrecoverable. The action flags use the defaults and ", 1806 "vary based on the severity." 1807 ] 1808 } 1809 }, 1810 1811 { 1812 "Name": "xyz.openbmc_project.Fan.Error.Missing", 1813 "Subsystem": "power_fans", 1814 "ComponentID": "0x2800", 1815 "Severity": "unrecoverable_redundancy_loss", 1816 "ActionFlags": ["service_action", "report", "call_home"], 1817 1818 "SRC": { 1819 "Type": "11", 1820 "ReasonCode": "0x76F1", 1821 "Words6To9": {} 1822 }, 1823 1824 "Callouts": [ 1825 { 1826 "System": "ibm,rainier", 1827 "CalloutList": [ 1828 { 1829 "Priority": "high", 1830 "SymbolicFRUTrusted": "air_mover", 1831 "UseInventoryLocCode": true 1832 }, 1833 { 1834 "Priority": "low", 1835 "LocCode": "P0" 1836 } 1837 ] 1838 }, 1839 { 1840 "System": "ibm,everest", 1841 "CalloutList": [ 1842 { 1843 "Priority": "high", 1844 "SymbolicFRUTrusted": "air_mover", 1845 "UseInventoryLocCode": true 1846 }, 1847 { 1848 "Priority": "low", 1849 "LocCode": "P1" 1850 } 1851 ] 1852 } 1853 ], 1854 1855 "Documentation": { 1856 "Description": "A fan is missing", 1857 "Message": "A fan is missing", 1858 "Notes": [ 1859 "This error occurs when a fan has been missing for a ", 1860 "certain amount of time. The first callout is the ", 1861 "symbolic FRU AIR_MOVR that has the trusted fan location ", 1862 "code, which it gets using the passed in ", 1863 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 1864 "where the controller and GPIO expander are." 1865 ] 1866 } 1867 }, 1868 1869 { 1870 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 1871 "ComponentID": "0x2800", 1872 "Subsystem": "power_fans", 1873 "Severity": "non_error", 1874 "ActionFlags": ["report"], 1875 "MfgSeverity": "predictive", 1876 "MfgActionFlags": ["service_action", "report"], 1877 1878 "SRC": { 1879 "Type": "11", 1880 "ReasonCode": "0x76F2", 1881 "Words6To9": {} 1882 }, 1883 1884 "Callouts": [ 1885 { 1886 "System": "ibm,rainier", 1887 "CalloutList": [ 1888 {"Priority": "medium", "LocCode": "P0"} 1889 ] 1890 }, 1891 { 1892 "System": "ibm,everest", 1893 "CalloutList": [ 1894 {"Priority": "medium", "LocCode": "P1"} 1895 ] 1896 } 1897 ], 1898 1899 "Documentation": { 1900 "Description": "Presence detect methods for the same fan disagree", 1901 "Message": "Presence detect methods for the same fan disagree", 1902 "Notes": [ 1903 "This error occurs when there is more than one way to detect", 1904 "fan presence, and they don't all agree. For example, the", 1905 "GPIO says a fan isn't present, but the tach readings are", 1906 "nonzero. This is informational, unless in manufacturing.", 1907 "The fan FRU is passed in as a high priority callout.", 1908 "The FRU the GPIO source is on is called out medium." 1909 ] 1910 } 1911 }, 1912 1913 { 1914 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 1915 "ComponentID": "0x2800", 1916 "Subsystem": "power_fans", 1917 "Severity": "critical_system_term", 1918 "ActionFlags": ["service_action", "report", "call_home"], 1919 1920 "SRC": { 1921 "Type": "11", 1922 "ReasonCode": "0x76F3", 1923 "Words6To9": {}, 1924 "PowerFault": true 1925 }, 1926 1927 "Callouts": [ 1928 { 1929 "System": "ibm,rainier", 1930 "CalloutList": [ 1931 {"Priority": "high", "LocCode": "P0-C5"}, 1932 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 1933 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 1934 {"Priority": "low", "LocCode": "P0"} 1935 ] 1936 }, 1937 { 1938 "System": "ibm,everest", 1939 "CalloutList": [ 1940 {"Priority": "high", "LocCode": "P0-C0"}, 1941 {"Priority": "medium", "LocCode": "P1"}, 1942 {"Priority": "low", "LocCode": "P0"} 1943 ] 1944 } 1945 ], 1946 1947 "Documentation": { 1948 "Description": "The fan controller device is offline", 1949 "Message": "The fan controller is offline. The system must be powered off.", 1950 "Notes": [ 1951 "The device that controls the fans is offline so the fan", 1952 "targets and speeds are unknown. The system will be shut", 1953 "down to preserve thermal safety. There may be an I2C", 1954 "or power problem with the device." 1955 ] 1956 } 1957 }, 1958 1959 { 1960 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 1961 "Subsystem": "power_fans", 1962 "ComponentID": "0x2800", 1963 "Severity": "unrecoverable_redundancy_loss", 1964 "ActionFlags": ["service_action", "report", "call_home"], 1965 1966 "SRC": { 1967 "Type": "11", 1968 "ReasonCode": "0x76F4", 1969 "Words6To9": {} 1970 }, 1971 1972 "Callouts": [ 1973 { 1974 "System" : "ibm,rainier", 1975 "CalloutList": [ 1976 {"Priority": "high", "LocCode": "P0-C5"}, 1977 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 1978 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 1979 {"Priority": "low", "LocCode": "P0"} 1980 ] 1981 }, 1982 { 1983 "System" : "ibm,everest", 1984 "CalloutList": [ 1985 {"Priority": "high", "LocCode": "P0-C0"}, 1986 {"Priority": "medium", "LocCode": "P1"}, 1987 {"Priority": "low", "LocCode": "P0"} 1988 ] 1989 } 1990 ], 1991 1992 "Documentation": { 1993 "Description": "Fan GPIO sensors not present", 1994 "Message": "Fan GPIO sensors not present", 1995 "Notes": [ 1996 "The device that reports fan presence is not functioning." 1997 ] 1998 } 1999 }, 2000 2001 { 2002 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 2003 "Subsystem": "power", 2004 "ComponentID": "0x2800", 2005 "Severity": "predictive", 2006 "ActionFlags": ["service_action", "report"], 2007 2008 "SRC": { 2009 "ReasonCode": "0x2801", 2010 "Words6To9": {} 2011 }, 2012 2013 "CalloutsUsingAD": { 2014 "ADName": "SENSOR_NAME", 2015 "CalloutsWithTheirADValues": [ 2016 { 2017 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2018 "Callouts": [ 2019 { 2020 "CalloutList": [ 2021 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2022 ] 2023 } 2024 ] 2025 } 2026 ] 2027 }, 2028 2029 "Documentation": { 2030 "Description": "A temperature sensor exceeded its performance loss threshold.", 2031 "Message": "A temperature sensor exceeded its performance loss threshold.", 2032 "Notes": [ 2033 "A temperature sensor crossed its performance loss threshold value", 2034 "If it is the ambient sensor, then a symbolic FRU will be added.", 2035 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2036 "a FRU callout." 2037 ] 2038 } 2039 }, 2040 2041 { 2042 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 2043 "Subsystem": "power", 2044 "ComponentID": "0x2800", 2045 "Severity": "non_error", 2046 "ActionFlags": ["report"], 2047 "EventType": "env_normal", 2048 2049 "SRC": { 2050 "ReasonCode": "0x2802", 2051 "Words6To9": {} 2052 }, 2053 2054 "CalloutsUsingAD": { 2055 "ADName": "SENSOR_NAME", 2056 "CalloutsWithTheirADValues": [ 2057 { 2058 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2059 "Callouts": [ 2060 { 2061 "CalloutList": [ 2062 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2063 ] 2064 } 2065 ] 2066 } 2067 ] 2068 }, 2069 2070 "Documentation": { 2071 "Description": "A temperature sensor is under its performance loss threshold.", 2072 "Message": "A temperature sensor is under its performance loss threshold.", 2073 "Notes": [ 2074 "A temperature sensor crossed under its performance loss threshold value", 2075 "If it is the ambient sensor, then a symbolic FRU will be added." 2076 ] 2077 } 2078 }, 2079 2080 { 2081 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 2082 "Subsystem": "power", 2083 "ComponentID": "0x2800", 2084 "Severity": "predictive", 2085 "ActionFlags": ["service_action", "report"], 2086 2087 "SRC": { 2088 "ReasonCode": "0x2803", 2089 "Words6To9": {} 2090 }, 2091 2092 "CalloutsUsingAD": { 2093 "ADName": "SENSOR_NAME", 2094 "CalloutsWithTheirADValues": [ 2095 { 2096 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2097 "Callouts": [ 2098 { 2099 "CalloutList": [ 2100 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2101 ] 2102 } 2103 ] 2104 } 2105 ] 2106 }, 2107 2108 "Documentation": { 2109 "Description": "A temperature sensor exceeded its warning threshold.", 2110 "Message": "A temperature sensor exceeded its warning threshold.", 2111 "Notes": [ 2112 "A temperature sensor crossed its warning threshold value", 2113 "If it is the ambient sensor, then a symbolic FRU will be added.", 2114 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2115 "a FRU callout." 2116 ] 2117 } 2118 }, 2119 2120 { 2121 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 2122 "Subsystem": "power", 2123 "ComponentID": "0x2800", 2124 "Severity": "non_error", 2125 "ActionFlags": ["report"], 2126 "EventType": "env_normal", 2127 2128 "SRC": { 2129 "ReasonCode": "0x2804", 2130 "Words6To9": {} 2131 }, 2132 2133 "CalloutsUsingAD": { 2134 "ADName": "SENSOR_NAME", 2135 "CalloutsWithTheirADValues": [ 2136 { 2137 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2138 "Callouts": [ 2139 { 2140 "CalloutList": [ 2141 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2142 ] 2143 } 2144 ] 2145 } 2146 ] 2147 }, 2148 2149 "Documentation": { 2150 "Description": "A temperature sensor is under its warning threshold.", 2151 "Message": "A temperature sensor is under its warning threshold.", 2152 "Notes": [ 2153 "A temperature sensor crossed under its warning threshold value", 2154 "If it is the ambient sensor, then a symbolic FRU will be added." 2155 ] 2156 } 2157 }, 2158 2159 { 2160 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 2161 "Subsystem": "power", 2162 "ComponentID": "0x2800", 2163 "Severity": "predictive", 2164 "ActionFlags": ["service_action", "report"], 2165 2166 "SRC": { 2167 "ReasonCode": "0x2805", 2168 "Words6To9": {} 2169 }, 2170 2171 "CalloutsUsingAD": { 2172 "ADName": "SENSOR_NAME", 2173 "CalloutsWithTheirADValues": [ 2174 { 2175 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2176 "Callouts": [ 2177 { 2178 "CalloutList": [ 2179 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2180 ] 2181 } 2182 ] 2183 } 2184 ] 2185 }, 2186 2187 "Documentation": { 2188 "Description": "A temperature sensor exceeded its critical threshold.", 2189 "Message": "A temperature sensor exceeded its critical threshold.", 2190 "Notes": [ 2191 "A temperature sensor crossed its critical threshold value", 2192 "If it is the ambient sensor, then a symbolic FRU will be added.", 2193 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2194 "a FRU callout." 2195 ] 2196 } 2197 }, 2198 2199 { 2200 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 2201 "Subsystem": "power", 2202 "ComponentID": "0x2800", 2203 "Severity": "non_error", 2204 "ActionFlags": ["report"], 2205 "EventType": "env_normal", 2206 2207 "SRC": { 2208 "ReasonCode": "0x2806", 2209 "Words6To9": {} 2210 }, 2211 2212 "CalloutsUsingAD": { 2213 "ADName": "SENSOR_NAME", 2214 "CalloutsWithTheirADValues": [ 2215 { 2216 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2217 "Callouts": [ 2218 { 2219 "CalloutList": [ 2220 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2221 ] 2222 } 2223 ] 2224 } 2225 ] 2226 }, 2227 2228 "Documentation": { 2229 "Description": "A temperature sensor is under its critical threshold.", 2230 "Message": "A temperature sensor is under its critical threshold.", 2231 "Notes": [ 2232 "A temperature sensor crossed under its critical threshold value", 2233 "If it is the ambient sensor, then a symbolic FRU will be added." 2234 ] 2235 } 2236 }, 2237 2238 { 2239 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 2240 "Subsystem": "power", 2241 "ComponentID": "0x2800", 2242 "Severity": "predictive", 2243 "ActionFlags": ["service_action", "report"], 2244 2245 "SRC": { 2246 "ReasonCode": "0x2807", 2247 "Words6To9": {} 2248 }, 2249 2250 "Callouts": [ 2251 { 2252 "CalloutList": [ 2253 { 2254 "Priority": "high", 2255 "SymbolicFRU": "ambient_temp" 2256 } 2257 ] 2258 } 2259 ], 2260 2261 "Documentation": { 2262 "Description": "The ambient temperature passed the EPOW3 limit.", 2263 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 2264 "Notes": [ 2265 "This error occurs when the ambient temperature surpassed", 2266 "the EPOW3 shutdown limit." 2267 ] 2268 } 2269 }, 2270 2271 { 2272 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 2273 "Subsystem": "power", 2274 "ComponentID": "0x2800", 2275 "Severity": "non_error", 2276 "ActionFlags": ["report"], 2277 "EventType": "env_normal", 2278 2279 "SRC": { 2280 "ReasonCode": "0x2808", 2281 "Words6To9": {} 2282 }, 2283 2284 "Callouts": [ 2285 { 2286 "CalloutList": [ 2287 { 2288 "Priority": "high", 2289 "SymbolicFRU": "ambient_temp_back" 2290 } 2291 ] 2292 } 2293 ], 2294 2295 "Documentation": { 2296 "Description": "The ambient temperature is back under the EPOW3 limit.", 2297 "Message": "The ambient temperature is back under the EPOW3 limit." 2298 } 2299 }, 2300 2301 { 2302 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 2303 "Subsystem": "power", 2304 "ComponentID": "0x2800", 2305 "ActionFlags": ["service_action", "report"], 2306 2307 "SRC": { 2308 "ReasonCode": "0x2809", 2309 "Words6To9": {} 2310 }, 2311 2312 "Callouts": [ 2313 { 2314 "CalloutList": [ 2315 { 2316 "Priority": "high", 2317 "SymbolicFRU": "ambient_temp" 2318 } 2319 ] 2320 } 2321 ], 2322 2323 "Documentation": { 2324 "Description": "The ambient temperature passed the EPOW4 limit.", 2325 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 2326 "Notes": [ 2327 "This error occurs when the ambient temperature surpassed", 2328 "the EPOW4 shutdown limit." 2329 ] 2330 } 2331 }, 2332 2333 { 2334 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 2335 "Subsystem": "ext_env", 2336 "ComponentID": "0x2800", 2337 "Severity": "predictive", 2338 "ActionFlags": ["service_action", "report"], 2339 2340 "SRC": { 2341 "ReasonCode": "0x280A", 2342 "Words6To9": {} 2343 }, 2344 2345 "CalloutsUsingAD": { 2346 "ADName": "SENSOR_NAME", 2347 "CalloutsWithTheirADValues": [ 2348 { 2349 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 2350 "Callouts": [ 2351 { 2352 "CalloutList": [ 2353 { "Priority": "high", "SymbolicFRU": "altitude" } 2354 ] 2355 } 2356 ] 2357 } 2358 ] 2359 }, 2360 2361 "Documentation": { 2362 "Description": "An altitude sensor exceeded its warning threshold.", 2363 "Message": "An altitude sensor exceeded its warning threshold.", 2364 "Notes": [ 2365 "The virtual altitude sensor crossed its warning threshold value", 2366 " and a symbolic FRU will be added." 2367 ] 2368 } 2369 }, 2370 2371 { 2372 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 2373 "Subsystem": "ext_env", 2374 "ComponentID": "0x2800", 2375 "Severity": "non_error", 2376 "ActionFlags": ["report"], 2377 "EventType": "env_normal", 2378 2379 "SRC": { 2380 "ReasonCode": "0x280B", 2381 "Words6To9": {} 2382 }, 2383 2384 "Documentation": { 2385 "Description": "An altitude sensor is under its warning threshold.", 2386 "Message": "An altitude sensor is under its warning threshold.", 2387 "Notes": [ 2388 "The virtual altitude sensor is under its warning threshold value", 2389 " and a symbolic FRU will be added." 2390 ] 2391 } 2392 }, 2393 2394 { 2395 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 2396 "Subsystem": "cec_vpd", 2397 "ComponentID": "0x4000", 2398 2399 "SRC": { 2400 "ReasonCode": "0x4000", 2401 "Words6To9": 2402 { 2403 "6": 2404 { 2405 "Description": "Errno of the failure.", 2406 "AdditionalDataPropSource": "CALLOUT_ERRNO" 2407 } 2408 } 2409 }, 2410 2411 "Documentation": { 2412 "Description": "A path access error ocurred", 2413 "Message": "An EEPROM path access error occurred.", 2414 "Notes": [ 2415 "This error occurs when parser is unable to access", 2416 "EEPROM path. Errno and device path are captured as", 2417 "additional data." 2418 ] 2419 } 2420 }, 2421 2422 { 2423 "Name": "com.ibm.VPD.Error.InvalidVPD", 2424 "Subsystem": "cec_vpd", 2425 "ComponentID": "0x4000", 2426 2427 "SRC": { 2428 "ReasonCode": "0x4001", 2429 "Words6To9": 2430 { 2431 } 2432 }, 2433 2434 "Documentation": { 2435 "Description": "Invalid VPD data.", 2436 "Message": "A VPD data exception occurred.", 2437 "Notes": [ 2438 "This error occurs when VPD data is found to be", 2439 "invalid. This can be when VPD file is missing out", 2440 "mandatory records.Inventory path is captured in", 2441 "additional data." 2442 ] 2443 } 2444 }, 2445 2446 { 2447 "Name": "com.ibm.VPD.Error.EccCheckFailed", 2448 "Subsystem": "cec_vpd", 2449 "ComponentID": "0x4000", 2450 2451 "SRC": { 2452 "ReasonCode": "0x4002", 2453 "Words6To9": 2454 { 2455 } 2456 }, 2457 2458 "Documentation": { 2459 "Description": "Invalid VPD ecc data.", 2460 "Message": "A VPD ecc exception occurred.", 2461 "Notes": [ 2462 "This error occurs when VPD ecc check fails for the FRU.", 2463 "Inventory path for the failed FRU is captured in additonal", 2464 "data." 2465 ] 2466 } 2467 }, 2468 2469 { 2470 "Name": "com.ibm.VPD.Error.InvalidJson", 2471 "Subsystem": "cec_vpd", 2472 "ComponentID": "0x4000", 2473 2474 "SRC": { 2475 "ReasonCode": "0x4003", 2476 "Words6To9": 2477 { 2478 } 2479 }, 2480 2481 "Documentation": { 2482 "Description": "Invalid Json", 2483 "Message": "A Json failure occurred.", 2484 "Notes": [ 2485 "This error occurs when parser fails to access", 2486 "Json file or there is any issue with Json data.", 2487 "Failed Json path and cause of failure is captured", 2488 "in additional data." 2489 ] 2490 } 2491 }, 2492 2493 { 2494 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 2495 "Subsystem": "cec_vpd", 2496 "ComponentID": "0x4000", 2497 2498 "SRC": { 2499 "ReasonCode": "0x4004", 2500 "Words6To9": 2501 { 2502 } 2503 }, 2504 2505 "Documentation": { 2506 "Description": "System VPD restore failed", 2507 "Message": "A system VPD restoration error occurred.", 2508 "Notes": [ 2509 "This error occurs when restoring of system VPD fails.", 2510 "The FRU path and reason for failure is captured in", 2511 "additional data." 2512 ] 2513 } 2514 }, 2515 2516 { 2517 "Name": "com.ibm.VPD.Error.DbusFailure", 2518 "Subsystem": "cec_vpd", 2519 "ComponentID": "0x4000", 2520 2521 "SRC": { 2522 "ReasonCode": "0x4005", 2523 "Words6To9": 2524 { 2525 } 2526 }, 2527 2528 "Documentation": { 2529 "Description": "Dbus exception", 2530 "Message": "A Dbus internal error occurred.", 2531 "Notes": [ 2532 "This error occurs when Dbus operation fails.", 2533 "Exceptions details are captured in additonal", 2534 "data." 2535 ] 2536 } 2537 }, 2538 2539 { 2540 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 2541 "Subsystem": "cec_sp_hostboot_iface", 2542 2543 "SRC": 2544 { 2545 "ReasonCode": "0xC101", 2546 "Words6To9": 2547 { 2548 } 2549 }, 2550 2551 "Documentation": 2552 { 2553 "Description": "Host did not respond within the watchdog timeout interval", 2554 "Message": "Host did not respond before the watchdog timeout interval expired", 2555 "Notes": [ 2556 "Host did not respond before the expiry of the watchdog timeout interval.", 2557 "Collecting hostboot dump." 2558 ] 2559 } 2560 } 2561 2562 ] 2563} 2564