1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 "Severity": "non_error", 8 9 "SRC": 10 { 11 "ReasonCode": "0x1001", 12 "Words6To9": 13 { 14 "6": 15 { 16 "Description": "Timeout in ms", 17 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 18 } 19 } 20 }, 21 22 "Documentation": 23 { 24 "Description": "This is a generic timeout error", 25 "Message": "An operation timed out", 26 "Notes": [ 27 "The journal should contain more information" 28 ] 29 } 30 }, 31 32 { 33 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 34 "Subsystem": "bmc_firmware", 35 "Severity": "non_error", 36 37 "SRC": 38 { 39 "ReasonCode": "0x1002", 40 "Words6To9": 41 { 42 } 43 }, 44 45 "Documentation": 46 { 47 "Description": "BMC code had a generic internal failure", 48 "Message": "An application had an internal failure", 49 "Notes": [ 50 "The journal should contain more information" 51 ] 52 } 53 }, 54 55 { 56 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 57 "Subsystem": "user_error", 58 "Severity": "non_error", 59 60 "SRC": 61 { 62 "ReasonCode": "0x1003", 63 "Words6To9": 64 { 65 } 66 }, 67 68 "Documentation": 69 { 70 "Description": "BMC code was given an invalid argument", 71 "Message": "Code was given an invalid argument", 72 "Notes": [ 73 "The journal should contain more information" 74 ] 75 } 76 }, 77 { 78 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 79 "Subsystem": "user_error", 80 "Severity": "non_error", 81 82 "SRC": 83 { 84 "ReasonCode": "0x1004", 85 "Words6To9": 86 { 87 } 88 }, 89 90 "Documentation": 91 { 92 "Description": "An operation failed due to insufficient permission", 93 "Message": "An operation failed due to unsufficient permission", 94 "Notes": [ 95 "The journal should contain more information" 96 ] 97 } 98 }, 99 100 { 101 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 102 "Subsystem": "user_error", 103 "Severity": "non_error", 104 105 "SRC": 106 { 107 "ReasonCode": "0x1005", 108 "Words6To9": 109 { 110 } 111 }, 112 113 "Documentation": 114 { 115 "Description": "An operation failed because it isn't allowed", 116 "Message": "An operation failed because it isn't allowed", 117 "Notes": [ 118 "The journal should contain more information" 119 ] 120 } 121 }, 122 123 { 124 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 125 "Subsystem": "user_error", 126 "Severity": "non_error", 127 128 "SRC": 129 { 130 "ReasonCode": "0x1006", 131 "Words6To9": 132 { 133 } 134 }, 135 136 "Documentation": 137 { 138 "Description": "The server's CA certificate has not been provided", 139 "Message": "The server's CA certificate has not been provided" 140 } 141 }, 142 143 { 144 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 145 "Subsystem": "cec_i2c", 146 147 "SRC": 148 { 149 "ReasonCode": "0x1007", 150 "Words6To9": 151 { 152 "6": 153 { 154 "Description": "errno of the failure", 155 "AdditionalDataPropSource": "CALLOUT_ERRNO" 156 } 157 } 158 }, 159 160 "Documentation": 161 { 162 "Description": "Sensor device read failure", 163 "Message": "There was a failure when reading a sensor device", 164 "Notes": [ 165 "The severity is set by the creator.", 166 "The action flags are set automatically by the code.", 167 "Callouts added based on CALLOUT_DEVICE_PATH." 168 ] 169 } 170 }, 171 172 { 173 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 174 "Subsystem": "cec_i2c", 175 176 "SRC": 177 { 178 "ReasonCode": "0x1008", 179 "Words6To9": 180 { 181 "6": 182 { 183 "Description": "errno of the failure", 184 "AdditionalDataPropSource": "CALLOUT_ERRNO" 185 } 186 } 187 }, 188 189 "Documentation": 190 { 191 "Description": "Device read failure", 192 "Message": "There was a failure when reading a hardware device", 193 "Notes": [ 194 "The severity is set by the creator.", 195 "The action flags are set automatically by the code.", 196 "Callouts added based on CALLOUT_DEVICE_PATH." 197 ] 198 } 199 }, 200 201 { 202 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 203 "Subsystem": "cec_i2c", 204 205 "SRC": 206 { 207 "ReasonCode": "0x1009", 208 "Words6To9": 209 { 210 "6": 211 { 212 "Description": "errno of the failure", 213 "AdditionalDataPropSource": "CALLOUT_ERRNO" 214 } 215 } 216 }, 217 218 "Documentation": 219 { 220 "Description": "Device write failure", 221 "Message": "There was a failure when writing to a hardware device", 222 "Notes": [ 223 "The severity is set by the creator.", 224 "The action flags are set automatically by the code.", 225 "Callouts added based on CALLOUT_DEVICE_PATH" 226 ] 227 } 228 }, 229 230 { 231 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 232 "Subsystem": "cec_i2c", 233 234 "SRC": 235 { 236 "ReasonCode": "0x100A", 237 "Words6To9": 238 { 239 "6": 240 { 241 "Description": "errno of the failure", 242 "AdditionalDataPropSource": "CALLOUT_ERRNO" 243 } 244 } 245 }, 246 247 "Documentation": 248 { 249 "Description": "Device write failure", 250 "Message": "There was a failure when writing to a hardware device", 251 "Notes": [ 252 "The severity is set by the creator.", 253 "The action flags are set automatically by the code.", 254 "Callouts added based on CALLOUT_DEVICE_PATH" 255 ] 256 } 257 }, 258 259 { 260 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 261 "Subsystem": "bmc_firmware", 262 "Severity": "non_error", 263 264 "SRC": 265 { 266 "ReasonCode": "0x2001", 267 "Words6To9": 268 { 269 "6": 270 { 271 "Description": "The bad PEL ID", 272 "AdditionalDataPropSource": "BAD_ID" 273 } 274 } 275 }, 276 277 "Documentation": 278 { 279 "Description": "The BMC sent the host a malformed PEL", 280 "Message": "The BMC sent the host a malformed PEL", 281 "Notes": [ 282 "The host firmware rejected that PEL." 283 ] 284 } 285 }, 286 287 { 288 "Name": "org.open_power.Logging.Error.BadHostPEL", 289 "Subsystem": "platform_firmware", 290 "Severity": "unrecoverable", 291 292 "SRC": 293 { 294 "ReasonCode": "0x2002", 295 "Words6To9": 296 { 297 "6": 298 { 299 "Description": "The PLID of the invalid PEL", 300 "AdditionalDataPropSource": "PLID" 301 }, 302 "7": 303 { 304 "Description": "The corresponding OpenBMC event log ID", 305 "AdditionalDataPropSource": "OBMC_LOG_ID" 306 }, 307 "8": 308 { 309 "Description": "The size of the invalid PEL", 310 "AdditionalDataPropSource": "PEL_SIZE" 311 } 312 } 313 }, 314 315 "Callouts": [ 316 { 317 "CalloutList": [ 318 { "Priority": "high", "Procedure": "bmc_code" } 319 ] 320 } 321 ], 322 323 "Documentation": 324 { 325 "Description": "The host sent the BMC an invalid PEL", 326 "Message": "The host sent the BMC an invalid PEL", 327 "Notes": [ 328 ] 329 } 330 }, 331 332 { 333 "Name": "org.open_power.Logging.Error.TestError1", 334 "Subsystem": "platform_firmware", 335 "Severity": "unrecoverable", 336 337 "SRC": 338 { 339 "ReasonCode": "0x2003", 340 "Words6To9": 341 { 342 } 343 }, 344 345 "Callouts": [ 346 { 347 "CalloutList": [ 348 {"Priority": "high", "Procedure": "bmc_code"}, 349 {"Priority": "medium", "SymbolicFRU": "service_docs"} 350 ] 351 } 352 ], 353 354 "Documentation": 355 { 356 "Description": "An error for testing", 357 "Message": "This is a test error" 358 } 359 }, 360 361 { 362 "Name": "xyz.openbmc_project.Logging.Error.Default", 363 "Subsystem": "other_na", 364 365 "SRC": 366 { 367 "ReasonCode": "0x2004", 368 "Words6To9": 369 { 370 } 371 }, 372 373 "Callouts": [ 374 { 375 "CalloutList": [ 376 { "Priority": "high", "Procedure": "bmc_code" } 377 ] 378 } 379 ], 380 381 "Documentation": 382 { 383 "Description": "This entry is used when no other matching entry is found", 384 "Message": "Unknown (Original event not in message registry)", 385 "Notes": [ 386 "This is used when the actual error name isn't found in ", 387 "the registry. The original error name will be stored ", 388 "in the UserData section that contains the AdditionalData ", 389 "properties using the key ERROR_NAME.", 390 "This error may contain callouts if the creator passed ", 391 "them in.", 392 "The severity is set by the creator.", 393 "If this error is seen, then a code change needs to be ", 394 "made to add the missing error entry to this registry." 395 ] 396 } 397 }, 398 399 { 400 "Name": "org.open_power.PHAL.Error.Boot", 401 "Subsystem": "cec_hardware", 402 "ComponentID": "0x3000", 403 "Severity": "unrecoverable", 404 405 "SRC": 406 { 407 "ReasonCode": "0x3001", 408 "Words6To9": 409 { 410 } 411 }, 412 413 "Documentation": 414 { 415 "Description": "Failure occured during boot process", 416 "Message": "Failure occured during boot process", 417 "Notes": [ 418 "Debug traces will be captured in AdditionalData section" 419 ] 420 } 421 }, 422 423 { 424 "Name": "org.open_power.PHAL.Error.PrePowerOff", 425 "Subsystem": "cec_hardware", 426 "ComponentID": "0x3000", 427 428 "SRC": 429 { 430 "ReasonCode": "0x3002", 431 "Words6To9": 432 { 433 } 434 }, 435 436 "Documentation": 437 { 438 "Description": "Failure occurred during PHAL pre-poweroff operations", 439 "Message": "Failure occurred during PHAL pre-poweroff operations", 440 "Notes": [ 441 "Severity needs to be set based on needs for this registry.", 442 "FFDC (First Failure Data Collection) will be collected ", 443 "and added into PEL." 444 ] 445 } 446 }, 447 448 { 449 "Name": "org.open_power.PHAL.Error.devtreeSync", 450 "Subsystem": "cec_hardware", 451 "ComponentID": "0x3000", 452 "Severity": "unrecoverable", 453 454 "SRC": 455 { 456 "ReasonCode": "0x3003", 457 "Words6To9": 458 { 459 } 460 }, 461 462 "Documentation": 463 { 464 "Description": "Failure occurred during PHAL devtree sync ", 465 "Message": "Failure occurred during PHAL devtree sync", 466 "Notes": [ 467 "The journal should contain more information" 468 ] 469 } 470 }, 471 472 { 473 "Name": "org.open_power.PHAL.Error.devtreeBackup", 474 "Subsystem": "cec_hardware", 475 "ComponentID": "0x3000", 476 "Severity": "unrecoverable", 477 478 "SRC": 479 { 480 "ReasonCode": "0x3004", 481 "Words6To9": 482 { 483 } 484 }, 485 486 "Documentation": 487 { 488 "Description": "Failure occurred during PHAL devtree backup ", 489 "Message": "Failure occurred during PHAL devtree backup", 490 "Notes": [ 491 "The journal should contain more information" 492 ] 493 } 494 }, 495 496 { 497 "Name": "org.open_power.PHAL.Error.HostRunning", 498 "Subsystem": "cec_sp_hostboot_iface", 499 "ComponentID": "0x3000", 500 501 "SRC": 502 { 503 "ReasonCode": "0x3005", 504 "Words6To9": 505 { 506 } 507 }, 508 509 "Documentation": 510 { 511 "Description": "Host did not respond to BMC after a BMC reset", 512 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 513 "Notes": [ 514 "System will be left in its current state to ensure host ", 515 "is not unexpectedly taken down. There is most likely an ", 516 "issue in the software or hardware communication path ", 517 "between the BMC and the Host firmware.", 518 "A BMC dump will be collected with relevant FFDC." 519 ] 520 } 521 }, 522 523 { 524 "Name": "org.open_power.PHAL.Error.devtreeReinit", 525 "Subsystem": "cec_hardware", 526 "ComponentID": "0x3000", 527 "Severity": "unrecoverable", 528 529 "SRC": 530 { 531 "ReasonCode": "0x3006", 532 "Words6To9": 533 { 534 } 535 }, 536 537 "Documentation": 538 { 539 "Description": "Failure re-initializing BMC to Host data structure", 540 "Message": "Failure occurred during re-initializing BMC to Host data structure", 541 "Notes": [ 542 "The journal should contain more information" 543 ] 544 } 545 }, 546 547 { 548 "Name": "org.open_power.HardwareIsolation.Error", 549 "Subsystem": "cec_hardware", 550 "ComponentID": "0x3100", 551 552 "SRC": 553 { 554 "ReasonCode": "0x3101", 555 "Words6To9": 556 { 557 } 558 }, 559 560 "Documentation": 561 { 562 "Description": "Failure occured during hardware isolation operations", 563 "Message": "Failure occured during hardware isolation operations", 564 "Notes": [ 565 "Severity needs to be set based on needs for this registry.", 566 "Debug traces will be captured in AdditionalData section" 567 ] 568 } 569 }, 570 571 { 572 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 573 "Subsystem": "cec_sp_hostboot_iface", 574 "ComponentID": "0x3400", 575 "SRC": 576 { 577 "ReasonCode": "0x3401", 578 "Words6To9": 579 { 580 } 581 }, 582 "Documentation": 583 { 584 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 585 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 586 "Notes": [ 587 "System will follow recovery policy, resulting in this ", 588 "error and most likely a a reboot of the host. The issue ", 589 "is most likely the result of the BMC rebooting while the ", 590 "host was booting and in a state where it still needed ", 591 "the BMC to complete its boot." 592 ] 593 } 594 }, 595 596 { 597 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 598 "Subsystem": "processor_chip", 599 "ComponentID": "0x3500", 600 601 "SRC": 602 { 603 "ReasonCode": "0x3500", 604 "Words6To9": 605 { 606 "6": 607 { 608 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 609 "AdditionalDataPropSource": "SRC6" 610 } 611 } 612 }, 613 614 "Documentation": 615 { 616 "Description": "chipop failure with SBE provided FFDC", 617 "Message": "chipop request failure reported by SBE", 618 "Notes": [ 619 "The severity is set by the creator.", 620 "Callouts added based on SBE provided FFDC.", 621 "SBE provided additional debug data included as part of the", 622 "additional user data section." 623 ] 624 } 625 }, 626 627 { 628 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 629 "Subsystem": "processor_chip", 630 "ComponentID": "0x3500", 631 632 "SRC": 633 { 634 "ReasonCode": "0x3501", 635 "Words6To9": 636 { 637 "6": 638 { 639 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 640 "AdditionalDataPropSource": "SRC6" 641 } 642 } 643 }, 644 645 "Documentation": 646 { 647 "Description": "SBE chipop timeout", 648 "Message": "chipop timeout reported during SBE communication", 649 "Notes": [ 650 "The severity is set by the creator.", 651 "Check SBE Dump associated to this error to debug the failure." 652 ] 653 } 654 }, 655 656 { 657 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 658 "Subsystem": "processor_chip", 659 "ComponentID": "0x3500", 660 661 "SRC": 662 { 663 "ReasonCode": "0x3502", 664 "Words6To9": 665 { 666 "6": 667 { 668 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 669 "AdditionalDataPropSource": "SRC6" 670 }, 671 "7": 672 { 673 "Description": "Value of SBE state", 674 "AdditionalDataPropSource": "SRC7" 675 } 676 } 677 }, 678 679 "Documentation": 680 { 681 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 682 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 683 "Notes": [ 684 "The severity is set by the creator." 685 ] 686 } 687 }, 688 689 { 690 "Name": "org.open_power.Processor.Error.SbeBootFailure", 691 "Subsystem": "processor_chip", 692 "ComponentID": "0x3500", 693 694 "SRC": 695 { 696 "ReasonCode": "0x3503", 697 "Words6To9": 698 { 699 "6": 700 { 701 "Description": "[0:15] chip position", 702 "AdditionalDataPropSource": "SRC6" 703 } 704 } 705 }, 706 707 "Documentation": 708 { 709 "Description": "Boot failure with SBE provided FFDC", 710 "Message": "Boot failure reported by SBE", 711 "Notes": [ 712 "The severity is set by the creator.", 713 "Callouts added based on SBE provided FFDC.", 714 "SBE provided additional debug data included as part of the", 715 "additional user data section." 716 ] 717 } 718 }, 719 720 { 721 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 722 "Subsystem": "processor_chip", 723 "ComponentID": "0x3500", 724 725 "SRC": 726 { 727 "ReasonCode": "0x3504", 728 "Words6To9": 729 { 730 } 731 }, 732 733 "Documentation": 734 { 735 "Description": "SBE Boot timeout", 736 "Message": "timeout reported during SBE boot process", 737 "Notes": [ 738 "The severity is set by the creator.", 739 "Check SBE Dump associated to this error to debug the failure." 740 ] 741 } 742 }, 743 744 { 745 "Name": "org.open_power.Attn.Error.Terminate", 746 "Subsystem": "cec_hardware", 747 "Severity": "non_error", 748 749 "SRC": 750 { 751 "ReasonCode": "0xD138", 752 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 753 "Words6To9": 754 { 755 } 756 }, 757 758 "Documentation": 759 { 760 "Description": "Status shows TI special attention active", 761 "Message": "TI special attention detected", 762 "Notes": [ 763 "This entry is for any TI special attention event ", 764 "reported by the attention handler component" 765 ] 766 } 767 }, 768 769 { 770 "Name": "org.open_power.Attn.Error.Fail", 771 "Subsystem": "bmc_firmware", 772 "Severity": "unrecoverable_loss_of_function", 773 774 "SRC": 775 { 776 "ReasonCode": "0xD13E", 777 "Words6To9": 778 { 779 "6": 780 { 781 "Description": "Error code from attention handler", 782 "AdditionalDataPropSource": "ERROR_CODE" 783 } 784 } 785 }, 786 "Documentation": 787 { 788 "Description": "The attention handler encountered an error", 789 "MessageArgSources" : ["SRCWord6"], 790 "Message": "Attention handler error %1", 791 "Notes": [ 792 "Attention handler will provide error code" 793 ] 794 } 795 }, 796 797 { 798 "Name": "org.open_power.Attn.Error.Vital", 799 "Subsystem": "processor_chip", 800 "Severity": "critical", 801 802 "SRC": 803 { 804 "ReasonCode": "0xD16D", 805 "Words6To9": 806 { 807 } 808 }, 809 810 "Documentation": 811 { 812 "Description": "Status shows SBE vital attention active", 813 "Message": "SBE vital attention detected", 814 "Notes": [ 815 "This entry is for any SBE vital attention event ", 816 "reported by the attention handler component" 817 ] 818 } 819 }, 820 821 { 822 "Name": "org.open_power.HwDiags.Error.Checkstop", 823 "Subsystem": "cec_hardware", 824 "ActionFlags": [ "service_action", "report", "call_home" ], 825 826 "SRC": 827 { 828 "ReasonCode": "0xE510", 829 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 830 "Words6To9": 831 { 832 "6": 833 { 834 "AdditionalDataPropSource": "SRC6" 835 }, 836 "7": 837 { 838 "AdditionalDataPropSource": "SRC7" 839 }, 840 "8": 841 { 842 "AdditionalDataPropSource": "SRC8" 843 } 844 } 845 }, 846 847 "Documentation": 848 { 849 "Description": "A system checkstop attention has occurred", 850 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 851 "Message": "Error Signature: %1 %2 %3" 852 } 853 }, 854 855 { 856 "Name": "org.open_power.HwDiags.Error.Predictive", 857 "Subsystem": "cec_hardware", 858 "ActionFlags": [ "service_action", "report", "call_home" ], 859 860 "SRC": 861 { 862 "ReasonCode": "0xE511", 863 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 864 "Words6To9": 865 { 866 "6": 867 { 868 "AdditionalDataPropSource": "SRC6" 869 }, 870 "7": 871 { 872 "AdditionalDataPropSource": "SRC7" 873 }, 874 "8": 875 { 876 "AdditionalDataPropSource": "SRC8" 877 } 878 } 879 }, 880 881 "Documentation": 882 { 883 "Description": "A hardware attention requiring service has occurred", 884 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 885 "Message": "Error Signature: %1 %2 %3" 886 } 887 }, 888 889 { 890 "Name": "org.open_power.HwDiags.Error.Informational", 891 "Subsystem": "cec_hardware", 892 "ActionFlags": [ "hidden", "dont_report" ], 893 894 "SRC": 895 { 896 "ReasonCode": "0xE512", 897 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 898 "Words6To9": 899 { 900 "6": 901 { 902 "AdditionalDataPropSource": "SRC6" 903 }, 904 "7": 905 { 906 "AdditionalDataPropSource": "SRC7" 907 }, 908 "8": 909 { 910 "AdditionalDataPropSource": "SRC8" 911 } 912 } 913 }, 914 915 "Documentation": 916 { 917 "Description": "Manual analysis was initiated via the command line. FFDC only.", 918 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 919 "Message": "Error Signature: %1 %2 %3" 920 } 921 }, 922 923 { 924 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 925 "Subsystem": "power_supply", 926 "Severity": "unrecoverable_redundancy_loss", 927 "ActionFlags": ["service_action", "report"], 928 "ComponentID": "0x2700", 929 930 "SRC": { 931 "Type": "11", 932 "ReasonCode": "0x15F0", 933 "Words6To9": {} 934 }, 935 936 "Callouts": [ 937 { 938 "CalloutList": [ 939 { "Priority": "high", "SymbolicFRU": "pwrsply" } 940 ] 941 } 942 ], 943 944 "Documentation": { 945 "Description": "Power Supply input power fault", 946 "Message": "A power supply has indicated an input or under voltage condition.", 947 "Notes": [ 948 "Check the power supply cabling and/or input power ", 949 "source. The PWRSPLY procedure is used rather than ", 950 "calling out a location code, as typically these faults ", 951 "are related to the supplied power, the cable, or the ", 952 "cable connectors. If the input fault resolves down to an ", 953 "issue with the power supply itself, the power supply ", 954 "indicating this input fault should be called out. Add the ", 955 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 956 "CALLOUT_PRIORITY to something other than high." 957 ] 958 } 959 }, 960 961 { 962 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 963 "Subsystem": "power_supply", 964 "Severity": "unrecoverable_redundancy_loss", 965 "ActionFlags": ["service_action", "report", "call_home"], 966 "ComponentID": "0x2700", 967 968 "SRC": { 969 "Type": "11", 970 "ReasonCode": "0x15F1", 971 "Words6To9": {} 972 }, 973 974 "Documentation": { 975 "Description": "Power Supply power fault", 976 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 977 "Notes": [ 978 "The power supply reporting the fault should be called ", 979 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 980 "specific fault, STATUS_* details, and code level in the ", 981 "AdditionalData section." 982 ] 983 } 984 }, 985 986 { 987 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 988 "Subsystem": "power_supply", 989 "Severity": "unrecoverable", 990 "ActionFlags": ["service_action", "report", "call_home"], 991 "ComponentID": "0x2700", 992 993 "SRC": { 994 "Type": "11", 995 "ReasonCode": "0x15F2", 996 "Words6To9": {} 997 }, 998 999 "Documentation": { 1000 "Description": "Power Supply non-power fault", 1001 "Message": "A communication failure occurred talking to the power supply", 1002 "Notes": [ 1003 "Communication problems with the power supply could be ", 1004 "the power supply, or any hardware between it and the ", 1005 "BMC. Reporting the error should be passing in a call ", 1006 "out using CALLOUT_DEVICE_PATH." 1007 ] 1008 } 1009 }, 1010 1011 { 1012 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 1013 "Subsystem": "power_supply", 1014 "Severity": "unrecoverable_redundancy_loss", 1015 "ActionFlags": ["service_action", "report", "call_home"], 1016 "ComponentID": "0x2700", 1017 1018 "SRC": { 1019 "Type": "11", 1020 "ReasonCode": "0x15F6", 1021 "Words6To9": {} 1022 }, 1023 1024 "Callouts": [ 1025 { 1026 "CalloutList": [ 1027 { 1028 "Priority": "high", 1029 "SymbolicFRUTrusted": "pwrsply", 1030 "UseInventoryLocCode": true 1031 } 1032 ] 1033 } 1034 ], 1035 1036 "Documentation": { 1037 "Description": "Power Supply is missing", 1038 "Message": "A power supply that should be present is missing", 1039 "Notes": [ 1040 "The CalloutList should use the PWRSPLY symbolic FRU ", 1041 "with the trusted location code property. The ", 1042 "location code in this callout is obtained from ", 1043 "the passed in CALLOUT_INVENTORY_PATH value." 1044 ] 1045 } 1046 }, 1047 1048 { 1049 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 1050 "Subsystem": "power_supply", 1051 "Severity": "unrecoverable", 1052 "ActionFlags": ["service_action", "report", "call_home"], 1053 "ComponentID": "0x2700", 1054 1055 "SRC": { 1056 "Type": "11", 1057 "ReasonCode": "0x15F7", 1058 "Words6To9": {} 1059 }, 1060 1061 "Documentation": { 1062 "Description": "Power Supply configuration is not supported", 1063 "Message": "The power supply configuration is not supported", 1064 "Notes": [ 1065 "The combination of power supplies detected in the ", 1066 "system is not supported. This could be caused by ", 1067 "mismatched models, less than expected number of power ", 1068 "supplies, or other unsupported characteristics." 1069 ] 1070 } 1071 }, 1072 1073 { 1074 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.FanFault", 1075 "Subsystem": "power_supply", 1076 "Severity": "unrecoverable", 1077 "ActionFlags": ["service_action", "report", "call_home"], 1078 "ComponentID": "0x2700", 1079 1080 "SRC": { 1081 "Type": "11", 1082 "ReasonCode": "0x15FF", 1083 "Words6To9": {} 1084 }, 1085 1086 "Documentation": { 1087 "Description": "Power Supply fan fault", 1088 "Message": "A power supply indicated a fan fault has occurred", 1089 "Notes": [ 1090 "The power supply reporting the fault should be called ", 1091 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1092 "specific fault, STATUS_* details, and code level in the ", 1093 "AdditionalData section." 1094 ] 1095 } 1096 }, 1097 1098 { 1099 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 1100 "Subsystem": "power_supply", 1101 "Severity": "unrecoverable_redundancy_loss", 1102 "ActionFlags": ["service_action", "report", "call_home"], 1103 "ComponentID": "0x2700", 1104 1105 "SRC": { 1106 "Type": "11", 1107 "ReasonCode": "0x1B01", 1108 "Words6To9": {} 1109 }, 1110 1111 "Callouts": [ 1112 { 1113 "CalloutList": [ 1114 { "Priority": "high", "Procedure": "power_overcurrent" } 1115 ] 1116 } 1117 ], 1118 1119 "Documentation": { 1120 "Description": "Power Supply output over-current power fault", 1121 "Message": "A power supply has indicated an output over-current condition." 1122 } 1123 }, 1124 1125 { 1126 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1127 "Subsystem": "power", 1128 "ActionFlags": [ "report", "service_action" ], 1129 "Severity": "unrecoverable", 1130 "ComponentID": "0x2700", 1131 1132 "SRC": 1133 { 1134 "Type": "11", 1135 "ReasonCode": "0x00AC", 1136 "Words6To9": {}, 1137 "PowerFault": true 1138 }, 1139 1140 "Callouts": [ 1141 { 1142 "CalloutList": [ 1143 { "Priority": "high", "SymbolicFRU": "ac_module"} 1144 ] 1145 } 1146 ], 1147 1148 "Documentation": { 1149 "Description": "Input power was lost while the system was powered on.", 1150 "Message": "Input power was lost while the system was powered on.", 1151 "Notes": [ 1152 "Input power was lost while system powered on.", 1153 "The CalloutList should use the ACMODUL symbolic FRU." 1154 ] 1155 } 1156 }, 1157 1158 { 1159 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1160 "Subsystem": "power_supply", 1161 "Severity": "unrecoverable", 1162 "ActionFlags": ["service_action", "report", "call_home"], 1163 "ComponentID": "0x2700", 1164 1165 "SRC": { 1166 "Type": "11", 1167 "ReasonCode": "0x2500", 1168 "Words6To9": {}, 1169 "PowerFault": true 1170 }, 1171 1172 "Callouts": [ 1173 { 1174 "CalloutList": [ 1175 { "Priority": "high", "Procedure": "power_overcurrent" } 1176 ] 1177 } 1178 ], 1179 1180 "Documentation": { 1181 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1182 "Message": "Power supply PSKill_fault", 1183 "Notes": [ 1184 ] 1185 } 1186 }, 1187 1188 { 1189 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1190 "Subsystem": "power_sequencer", 1191 "ComponentID": "0x2700", 1192 1193 "SRC": { 1194 "Type": "11", 1195 "ReasonCode": "0x2600", 1196 "Words6To9": {} 1197 }, 1198 1199 "Callouts": [ 1200 { 1201 "CalloutList": [ 1202 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1203 ] 1204 } 1205 ], 1206 1207 "Documentation": { 1208 "Description": "A power off was issued because a power fault was detected", 1209 "Message": "A power off was issued because a power fault was detected", 1210 "Notes": [ 1211 ] 1212 } 1213 }, 1214 1215 { 1216 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1217 "Subsystem": "power_control_hw", 1218 "ComponentID": "0x2700", 1219 1220 "SRC": { 1221 "Type": "11", 1222 "ReasonCode": "0x2602", 1223 "Words6To9": {}, 1224 "PowerFault": true 1225 }, 1226 1227 "Callouts": [ 1228 { 1229 "System": "ibm,rainier", 1230 "CalloutList": [ 1231 { 1232 "Priority": "high", 1233 "LocCode": "P0-C5" 1234 }, 1235 { 1236 "Priority": "medium", 1237 "LocCode": "P0" 1238 } 1239 ] 1240 }, 1241 { 1242 "System": "ibm,everest", 1243 "CalloutList": [ 1244 { 1245 "Priority": "high", 1246 "LocCode": "P0-C59" 1247 }, 1248 { 1249 "Priority": "medium", 1250 "LocCode": "P0" 1251 } 1252 ] 1253 } 1254 ], 1255 1256 "Documentation": { 1257 "Description": "A power off was issued because a regulator for standby power faulted", 1258 "Message": "A power off was issued because a regulator for standby power faulted", 1259 "Notes": [ 1260 ] 1261 } 1262 }, 1263 1264 { 1265 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1266 "Subsystem": "power_sequencer", 1267 "ComponentID": "0x2700", 1268 1269 "SRC": { 1270 "Type": "11", 1271 "ReasonCode": "0x2610", 1272 "Words6To9": {} 1273 }, 1274 1275 "CalloutsUsingAD": { 1276 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1277 { 1278 "ADValue": "PCIE_SLOT0", "Callouts": [ 1279 { 1280 "CalloutList": [ 1281 { "Priority": "high", "LocCode": "P0-C0" }, 1282 { "Priority": "medium", "LocCode": "P0" } 1283 ] 1284 } 1285 ] 1286 }, 1287 { 1288 "ADValue": "PCIE_SLOT1", "Callouts": [ 1289 { 1290 "CalloutList": [ 1291 { "Priority": "high", "LocCode": "P0-C1" }, 1292 { "Priority": "medium", "LocCode": "P0" } 1293 ] 1294 } 1295 ] 1296 }, 1297 { 1298 "ADValue": "PCIE_SLOT2", "Callouts": [ 1299 { 1300 "CalloutList": [ 1301 { "Priority": "high", "LocCode": "P0-C2" }, 1302 { "Priority": "medium", "LocCode": "P0" } 1303 ] 1304 } 1305 ] 1306 }, 1307 { 1308 "ADValue": "PCIE_SLOT3", "Callouts": [ 1309 { 1310 "CalloutList": [ 1311 { "Priority": "high", "LocCode": "P0-C3" }, 1312 { "Priority": "medium", "LocCode": "P0" } 1313 ] 1314 } 1315 ] 1316 }, 1317 { 1318 "ADValue": "PCIE_SLOT4", "Callouts": [ 1319 { 1320 "CalloutList": [ 1321 { "Priority": "high", "LocCode": "P0-C4" }, 1322 { "Priority": "medium", "LocCode": "P0" } 1323 ] 1324 } 1325 ] 1326 }, 1327 { 1328 "ADValue": "PCIE_SLOT5", "Callouts": [ 1329 { 1330 "CalloutList": [ 1331 { "Priority": "high", "LocCode": "P0-C5" }, 1332 { "Priority": "medium", "LocCode": "P0" } 1333 ] 1334 } 1335 ] 1336 }, 1337 { 1338 "ADValue": "PCIE_SLOT6", "Callouts": [ 1339 { 1340 "CalloutList": [ 1341 { "Priority": "high", "LocCode": "P0-C6" }, 1342 { "Priority": "medium", "LocCode": "P0" } 1343 ] 1344 } 1345 ] 1346 }, 1347 { 1348 "ADValue": "PCIE_SLOT7", "Callouts": [ 1349 { 1350 "CalloutList": [ 1351 { "Priority": "high", "LocCode": "P0-C7" }, 1352 { "Priority": "medium", "LocCode": "P0" } 1353 ] 1354 } 1355 ] 1356 }, 1357 { 1358 "ADValue": "PCIE_SLOT8", "Callouts": [ 1359 { 1360 "CalloutList": [ 1361 { "Priority": "high", "LocCode": "P0-C8" }, 1362 { "Priority": "medium", "LocCode": "P0" } 1363 ] 1364 } 1365 ] 1366 }, 1367 { 1368 "ADValue": "PCIE_SLOT9", "Callouts": [ 1369 { 1370 "CalloutList": [ 1371 { "Priority": "high", "LocCode": "P0-C9" }, 1372 { "Priority": "medium", "LocCode": "P0" } 1373 ] 1374 } 1375 ] 1376 }, 1377 { 1378 "ADValue": "PCIE_SLOT10", "Callouts": [ 1379 { 1380 "CalloutList": [ 1381 { "Priority": "high", "LocCode": "P0-C10" }, 1382 { "Priority": "medium", "LocCode": "P0" } 1383 ] 1384 } 1385 ] 1386 }, 1387 { 1388 "ADValue": "PCIE_SLOT11", "Callouts": [ 1389 { 1390 "CalloutList": [ 1391 { "Priority": "high", "LocCode": "P0-C11" }, 1392 { "Priority": "medium", "LocCode": "P0" } 1393 ] 1394 } 1395 ] 1396 }, 1397 { 1398 "ADValue": "PGOOD_12A", "Callouts": [ 1399 { 1400 "CalloutList": [ 1401 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1402 ] 1403 } 1404 ] 1405 }, 1406 { 1407 "ADValue": "PGOOD_12B", "Callouts": [ 1408 { 1409 "CalloutList": [ 1410 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1411 ] 1412 } 1413 ] 1414 }, 1415 { 1416 "ADValue": "PGOOD_12C", "Callouts": [ 1417 { 1418 "CalloutList": [ 1419 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1420 ] 1421 } 1422 ] 1423 }, 1424 { 1425 "ADValue": "PGOOD_12D", "Callouts": [ 1426 { 1427 "CalloutList": [ 1428 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1429 ] 1430 } 1431 ] 1432 }, 1433 { 1434 "ADValue": "PGOOD_12L", "Callouts": [ 1435 { 1436 "CalloutList": [ 1437 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1438 ] 1439 } 1440 ] 1441 }, 1442 { 1443 "ADValue": "PGOOD_12M", "Callouts": [ 1444 { 1445 "CalloutList": [ 1446 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1447 ] 1448 } 1449 ] 1450 }, 1451 { 1452 "ADValue": "PGOOD_12N", "Callouts": [ 1453 { 1454 "CalloutList": [ 1455 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1456 ] 1457 } 1458 ] 1459 }, 1460 { 1461 "ADValue": "PGOOD_12P", "Callouts": [ 1462 { 1463 "CalloutList": [ 1464 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1465 ] 1466 } 1467 ] 1468 }, 1469 { 1470 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1471 { 1472 "CalloutList": [ 1473 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1474 ] 1475 } 1476 ] 1477 }, 1478 { 1479 "ADValue": "PGOOD_12Q", "Callouts": [ 1480 { 1481 "CalloutList": [ 1482 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1483 ] 1484 } 1485 ] 1486 }, 1487 { 1488 "ADValue": "PGOOD_12R", "Callouts": [ 1489 { 1490 "CalloutList": [ 1491 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1492 ] 1493 } 1494 ] 1495 }, 1496 { 1497 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1498 { 1499 "CalloutList": [ 1500 { "Priority": "high", "LocCode": "P0-C14" }, 1501 { "Priority": "medium", "LocCode": "P0-C15" }, 1502 { "Priority": "low", "LocCode": "P0" } 1503 ] 1504 } 1505 ] 1506 }, 1507 { 1508 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1509 { 1510 "CalloutList": [ 1511 { "Priority": "high", "LocCode": "P0-C23" }, 1512 { "Priority": "medium", "LocCode": "P0-C24" }, 1513 { "Priority": "low", "LocCode": "P0" } 1514 ] 1515 } 1516 ] 1517 }, 1518 { 1519 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1520 { 1521 "CalloutList": [ 1522 { "Priority": "high", "LocCode": "P0-C14" }, 1523 { "Priority": "medium", "LocCode": "P0-C15" }, 1524 { "Priority": "low", "LocCode": "P0" } 1525 ] 1526 } 1527 ] 1528 }, 1529 { 1530 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1531 { 1532 "CalloutList": [ 1533 { "Priority": "high", "LocCode": "P0-C23" }, 1534 { "Priority": "medium", "LocCode": "P0-C24" }, 1535 { "Priority": "low", "LocCode": "P0" } 1536 ] 1537 } 1538 ] 1539 }, 1540 { 1541 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1542 { 1543 "CalloutList": [ 1544 { "Priority": "high", "LocCode": "P0-C14" }, 1545 { "Priority": "medium", "LocCode": "P0-C15" }, 1546 { "Priority": "low", "LocCode": "P0" } 1547 ] 1548 } 1549 ] 1550 }, 1551 { 1552 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1553 { 1554 "CalloutList": [ 1555 { "Priority": "high", "LocCode": "P0-C23" }, 1556 { "Priority": "medium", "LocCode": "P0-C24" }, 1557 { "Priority": "low", "LocCode": "P0" } 1558 ] 1559 } 1560 ] 1561 }, 1562 { 1563 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1564 { 1565 "CalloutList": [ 1566 { "Priority": "high", "LocCode": "P0-C14" }, 1567 { "Priority": "medium", "LocCode": "P0-C15" }, 1568 { "Priority": "low", "LocCode": "P0" } 1569 ] 1570 } 1571 ] 1572 }, 1573 { 1574 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1575 { 1576 "CalloutList": [ 1577 { "Priority": "high", "LocCode": "P0-C23" }, 1578 { "Priority": "medium", "LocCode": "P0-C24" }, 1579 { "Priority": "low", "LocCode": "P0" } 1580 ] 1581 } 1582 ] 1583 }, 1584 { 1585 "ADValue": "CP0_VPCIE", "Callouts": [ 1586 { 1587 "CalloutList": [ 1588 { "Priority": "high", "LocCode": "P0-C58" }, 1589 { "Priority": "medium", "LocCode": "P0-C60" }, 1590 { "Priority": "low", "LocCode": "P0" } 1591 ] 1592 } 1593 ] 1594 }, 1595 { 1596 "ADValue": "CP1_VPCIE", "Callouts": [ 1597 { 1598 "CalloutList": [ 1599 { "Priority": "high", "LocCode": "P0-C16" }, 1600 { "Priority": "medium", "LocCode": "P0-C13" }, 1601 { "Priority": "low", "LocCode": "P0" } 1602 ] 1603 } 1604 ] 1605 }, 1606 { 1607 "ADValue": "CP2_VPCIE", "Callouts": [ 1608 { 1609 "CalloutList": [ 1610 { "Priority": "high", "LocCode": "P0-C16" }, 1611 { "Priority": "medium", "LocCode": "P0-C20" }, 1612 { "Priority": "low", "LocCode": "P0" } 1613 ] 1614 } 1615 ] 1616 }, 1617 { 1618 "ADValue": "CP3_VPCIE", "Callouts": [ 1619 { 1620 "CalloutList": [ 1621 { "Priority": "high", "LocCode": "P0-C58" }, 1622 { "Priority": "medium", "LocCode": "P0-C56" }, 1623 { "Priority": "low", "LocCode": "P0" } 1624 ] 1625 } 1626 ] 1627 }, 1628 { 1629 "ADValue": "0V_USB_front", "Callouts": [ 1630 { 1631 "CalloutList": [ 1632 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1633 { "Priority": "medium", "LocCode": "P0" } 1634 ] 1635 } 1636 ] 1637 }, 1638 { 1639 "ADValue": "CP0_VDN", "Callouts": [ 1640 { 1641 "CalloutList": [ 1642 { "Priority": "high", "LocCode": "P0-C63" }, 1643 { "Priority": "medium", "LocCode": "P0-C60" }, 1644 { "Priority": "low", "LocCode": "P0" } 1645 ] 1646 } 1647 ] 1648 }, 1649 { 1650 "ADValue": "CP1_VDN", "Callouts": [ 1651 { 1652 "CalloutList": [ 1653 { "Priority": "high", "LocCode": "P0-C12" }, 1654 { "Priority": "medium", "LocCode": "P0-C13" }, 1655 { "Priority": "low", "LocCode": "P0" } 1656 ] 1657 } 1658 ] 1659 }, 1660 { 1661 "ADValue": "CP2_VDN", "Callouts": [ 1662 { 1663 "CalloutList": [ 1664 { "Priority": "high", "LocCode": "P0-C21" }, 1665 { "Priority": "medium", "LocCode": "P0-C20" }, 1666 { "Priority": "low", "LocCode": "P0" } 1667 ] 1668 } 1669 ] 1670 }, 1671 { 1672 "ADValue": "CP3_VDN", "Callouts": [ 1673 { 1674 "CalloutList": [ 1675 { "Priority": "high", "LocCode": "P0-C54" }, 1676 { "Priority": "medium", "LocCode": "P0-C56" }, 1677 { "Priority": "low", "LocCode": "P0" } 1678 ] 1679 } 1680 ] 1681 }, 1682 { 1683 "ADValue": "CP0_VIO", "Callouts": [ 1684 { 1685 "CalloutList": [ 1686 { "Priority": "high", "LocCode": "P0-C63" }, 1687 { "Priority": "medium", "LocCode": "P0-C60" }, 1688 { "Priority": "low", "LocCode": "P0" } 1689 ] 1690 } 1691 ] 1692 }, 1693 { 1694 "ADValue": "CP1_VIO", "Callouts": [ 1695 { 1696 "CalloutList": [ 1697 { "Priority": "high", "LocCode": "P0-C12" }, 1698 { "Priority": "medium", "LocCode": "P0-C13" }, 1699 { "Priority": "low", "LocCode": "P0" } 1700 ] 1701 } 1702 ] 1703 }, 1704 { 1705 "ADValue": "CP2_VIO", "Callouts": [ 1706 { 1707 "CalloutList": [ 1708 { "Priority": "high", "LocCode": "P0-C21" }, 1709 { "Priority": "medium", "LocCode": "P0-C20" }, 1710 { "Priority": "low", "LocCode": "P0" } 1711 ] 1712 } 1713 ] 1714 }, 1715 { 1716 "ADValue": "CP3_VIO", "Callouts": [ 1717 { 1718 "CalloutList": [ 1719 { "Priority": "high", "LocCode": "P0-C54" }, 1720 { "Priority": "medium", "LocCode": "P0-C56" }, 1721 { "Priority": "low", "LocCode": "P0" } 1722 ] 1723 } 1724 ] 1725 }, 1726 { 1727 "ADValue": "PGOOD_PSU1", "Callouts": [ 1728 { 1729 "CalloutList": [ 1730 { "Priority": "high", "LocCode": "E0" } 1731 ] 1732 } 1733 ] 1734 }, 1735 { 1736 "ADValue": "PGOOD_PSU2", "Callouts": [ 1737 { 1738 "CalloutList": [ 1739 { "Priority": "high", "LocCode": "E1" } 1740 ] 1741 } 1742 ] 1743 }, 1744 { 1745 "ADValue": "PGOOD_PSU3", "Callouts": [ 1746 { 1747 "CalloutList": [ 1748 { "Priority": "high", "LocCode": "E2" } 1749 ] 1750 } 1751 ] 1752 }, 1753 { 1754 "ADValue": "PGOOD_PSU4", "Callouts": [ 1755 { 1756 "CalloutList": [ 1757 { "Priority": "high", "LocCode": "E3" } 1758 ] 1759 } 1760 ] 1761 } 1762 ] 1763 }, 1764 1765 "Documentation": { 1766 "Description": "The power sequencer chip detected a PGOOD fault", 1767 "Message": "The power sequencer chip detected a PGOOD fault", 1768 "Notes": [ 1769 ] 1770 } 1771 }, 1772 1773 { 1774 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 1775 "Subsystem": "power_sequencer", 1776 "ComponentID": "0x2700", 1777 1778 "SRC": { 1779 "Type": "11", 1780 "ReasonCode": "0x2620", 1781 "Words6To9": {} 1782 }, 1783 1784 "CalloutsUsingAD": { 1785 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 1786 { 1787 "ADValue": "12.0V", "Callouts": [ 1788 { 1789 "CalloutList": [ 1790 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1791 ] 1792 } 1793 ] 1794 }, 1795 { 1796 "ADValue": "5.0V_USB", "Callouts": [ 1797 { 1798 "CalloutList": [ 1799 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1800 { "Priority": "medium", "LocCode": "P0" } 1801 ] 1802 } 1803 ] 1804 }, 1805 { 1806 "ADValue": "5.0V_DASD", "Callouts": [ 1807 { 1808 "CalloutList": [ 1809 { "Priority": "medium", "LocCode": "P1" }, 1810 { "Priority": "medium", "LocCode": "P2" }, 1811 { "Priority": "medium", "LocCode": "P3" }, 1812 { "Priority": "low", "LocCode": "P0" } 1813 ] 1814 } 1815 ] 1816 }, 1817 { 1818 "ADValue": "3.3VA", "Callouts": [ 1819 { 1820 "CalloutList": [ 1821 { "Priority": "high", "LocCode": "P0" } 1822 ] 1823 } 1824 ] 1825 }, 1826 { 1827 "ADValue": "3.3VB", "Callouts": [ 1828 { 1829 "CalloutList": [ 1830 { "Priority": "high", "LocCode": "P0" } 1831 ] 1832 } 1833 ] 1834 }, 1835 { 1836 "ADValue": "3V3IO", "Callouts": [ 1837 { 1838 "CalloutList": [ 1839 { "Priority": "high", "LocCode": "P0-C17" } 1840 ] 1841 } 1842 ] 1843 }, 1844 { 1845 "ADValue": "1.5V", "Callouts": [ 1846 { 1847 "CalloutList": [ 1848 { "Priority": "high", "LocCode": "P0" } 1849 ] 1850 } 1851 ] 1852 }, 1853 { 1854 "ADValue": "1.1V", "Callouts": [ 1855 { 1856 "CalloutList": [ 1857 { "Priority": "high", "LocCode": "P0" } 1858 ] 1859 } 1860 ] 1861 }, 1862 { 1863 "ADValue": "VDDA_DCM0", "Callouts": [ 1864 { 1865 "CalloutList": [ 1866 { "Priority": "high", "LocCode": "P0-C14" }, 1867 { "Priority": "medium", "LocCode": "P0-C15" }, 1868 { "Priority": "low", "LocCode": "P0" } 1869 ] 1870 } 1871 ] 1872 }, 1873 { 1874 "ADValue": "VDDB_DCM0", "Callouts": [ 1875 { 1876 "CalloutList": [ 1877 { "Priority": "high", "LocCode": "P0-C14" }, 1878 { "Priority": "medium", "LocCode": "P0-C15" }, 1879 { "Priority": "low", "LocCode": "P0" } 1880 ] 1881 } 1882 ] 1883 }, 1884 { 1885 "ADValue": "VDDA_DCM1", "Callouts": [ 1886 { 1887 "CalloutList": [ 1888 { "Priority": "high", "LocCode": "P0-C23" }, 1889 { "Priority": "medium", "LocCode": "P0-C24" }, 1890 { "Priority": "low", "LocCode": "P0" } 1891 ] 1892 } 1893 ] 1894 }, 1895 { 1896 "ADValue": "VDDB_DCM1", "Callouts": [ 1897 { 1898 "CalloutList": [ 1899 { "Priority": "high", "LocCode": "P0-C23" }, 1900 { "Priority": "medium", "LocCode": "P0-C24" }, 1901 { "Priority": "low", "LocCode": "P0" } 1902 ] 1903 } 1904 ] 1905 }, 1906 { 1907 "ADValue": "CP03_AVDD", "Callouts": [ 1908 { 1909 "CalloutList": [ 1910 { "Priority": "high", "LocCode": "P0-C58" }, 1911 { "Priority": "medium", "LocCode": "P0-C56" }, 1912 { "Priority": "medium", "LocCode": "P0-C61" }, 1913 { "Priority": "low", "LocCode": "P0" } 1914 ] 1915 } 1916 ] 1917 }, 1918 { 1919 "ADValue": "CP12_AVDD", "Callouts": [ 1920 { 1921 "CalloutList": [ 1922 { "Priority": "high", "LocCode": "P0-C16" }, 1923 { "Priority": "medium", "LocCode": "P0-C14" }, 1924 { "Priority": "medium", "LocCode": "P0-C19" }, 1925 { "Priority": "low", "LocCode": "P0" } 1926 ] 1927 } 1928 ] 1929 }, 1930 { 1931 "ADValue": "CP0_VDD0", "Callouts": [ 1932 { 1933 "CalloutList": [ 1934 { "Priority": "high", "LocCode": "P0-C62" }, 1935 { "Priority": "medium", "LocCode": "P0-C61" }, 1936 { "Priority": "low", "LocCode": "P0" } 1937 ] 1938 } 1939 ] 1940 }, 1941 { 1942 "ADValue": "CP0_VDD1", "Callouts": [ 1943 { 1944 "CalloutList": [ 1945 { "Priority": "high", "LocCode": "P0-C60" }, 1946 { "Priority": "medium", "LocCode": "P0-C61" }, 1947 { "Priority": "low", "LocCode": "P0" } 1948 ] 1949 } 1950 ] 1951 }, 1952 { 1953 "ADValue": "CP1_VDD0", "Callouts": [ 1954 { 1955 "CalloutList": [ 1956 { "Priority": "high", "LocCode": "P0-C13" }, 1957 { "Priority": "medium", "LocCode": "P0-C14" }, 1958 { "Priority": "low", "LocCode": "P0" } 1959 ] 1960 } 1961 ] 1962 }, 1963 { 1964 "ADValue": "CP1_VDD1", "Callouts": [ 1965 { 1966 "CalloutList": [ 1967 { "Priority": "high", "LocCode": "P0-C15" }, 1968 { "Priority": "medium", "LocCode": "P0-C14" }, 1969 { "Priority": "low", "LocCode": "P0" } 1970 ] 1971 } 1972 ] 1973 }, 1974 { 1975 "ADValue": "CP2_VDD0", "Callouts": [ 1976 { 1977 "CalloutList": [ 1978 { "Priority": "high", "LocCode": "P0-C18" }, 1979 { "Priority": "medium", "LocCode": "P0-C19" }, 1980 { "Priority": "low", "LocCode": "P0" } 1981 ] 1982 } 1983 ] 1984 }, 1985 { 1986 "ADValue": "CP2_VDD1", "Callouts": [ 1987 { 1988 "CalloutList": [ 1989 { "Priority": "high", "LocCode": "P0-C20" }, 1990 { "Priority": "medium", "LocCode": "P0-C19" }, 1991 { "Priority": "low", "LocCode": "P0" } 1992 ] 1993 } 1994 ] 1995 }, 1996 { 1997 "ADValue": "CP3_VDD0", "Callouts": [ 1998 { 1999 "CalloutList": [ 2000 { "Priority": "high", "LocCode": "P0-C57" }, 2001 { "Priority": "medium", "LocCode": "P0-C56" }, 2002 { "Priority": "low", "LocCode": "P0" } 2003 ] 2004 } 2005 ] 2006 }, 2007 { 2008 "ADValue": "CP3_VDD1", "Callouts": [ 2009 { 2010 "CalloutList": [ 2011 { "Priority": "high", "LocCode": "P0-C55" }, 2012 { "Priority": "medium", "LocCode": "P0-C56" }, 2013 { "Priority": "low", "LocCode": "P0" } 2014 ] 2015 } 2016 ] 2017 }, 2018 { 2019 "ADValue": "CP0_VCS0", "Callouts": [ 2020 { 2021 "CalloutList": [ 2022 { "Priority": "high", "LocCode": "P0-C63" }, 2023 { "Priority": "medium", "LocCode": "P0-C61" }, 2024 { "Priority": "low", "LocCode": "P0" } 2025 ] 2026 } 2027 ] 2028 }, 2029 { 2030 "ADValue": "CP0_VCS1", "Callouts": [ 2031 { 2032 "CalloutList": [ 2033 { "Priority": "high", "LocCode": "P0-C59" }, 2034 { "Priority": "medium", "LocCode": "P0-C61" }, 2035 { "Priority": "low", "LocCode": "P0" } 2036 ] 2037 } 2038 ] 2039 }, 2040 { 2041 "ADValue": "CP1_VCS0", "Callouts": [ 2042 { 2043 "CalloutList": [ 2044 { "Priority": "high", "LocCode": "P0-C12" }, 2045 { "Priority": "medium", "LocCode": "P0-C14" }, 2046 { "Priority": "low", "LocCode": "P0" } 2047 ] 2048 } 2049 ] 2050 }, 2051 { 2052 "ADValue": "CP1_VCS1", "Callouts": [ 2053 { 2054 "CalloutList": [ 2055 { "Priority": "high", "LocCode": "P0-C16" }, 2056 { "Priority": "medium", "LocCode": "P0-C14" }, 2057 { "Priority": "low", "LocCode": "P0" } 2058 ] 2059 } 2060 ] 2061 }, 2062 { 2063 "ADValue": "CP2_VCS0", "Callouts": [ 2064 { 2065 "CalloutList": [ 2066 { "Priority": "high", "LocCode": "P0-C17" }, 2067 { "Priority": "medium", "LocCode": "P0-C19" }, 2068 { "Priority": "low", "LocCode": "P0" } 2069 ] 2070 } 2071 ] 2072 }, 2073 { 2074 "ADValue": "CP2_VCS1", "Callouts": [ 2075 { 2076 "CalloutList": [ 2077 { "Priority": "high", "LocCode": "P0-C21" }, 2078 { "Priority": "medium", "LocCode": "P0-C19" }, 2079 { "Priority": "low", "LocCode": "P0" } 2080 ] 2081 } 2082 ] 2083 }, 2084 { 2085 "ADValue": "CP3_VCS0", "Callouts": [ 2086 { 2087 "CalloutList": [ 2088 { "Priority": "high", "LocCode": "P0-C58" }, 2089 { "Priority": "medium", "LocCode": "P0-C56" }, 2090 { "Priority": "low", "LocCode": "P0" } 2091 ] 2092 } 2093 ] 2094 }, 2095 { 2096 "ADValue": "CP3_VCS1", "Callouts": [ 2097 { 2098 "CalloutList": [ 2099 { "Priority": "high", "LocCode": "P0-C54" }, 2100 { "Priority": "medium", "LocCode": "P0-C56" }, 2101 { "Priority": "low", "LocCode": "P0" } 2102 ] 2103 } 2104 ] 2105 }, 2106 { 2107 "ADValue": "12.0VCS", "Callouts": [ 2108 { 2109 "CalloutList": [ 2110 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2111 ] 2112 } 2113 ] 2114 }, 2115 { 2116 "ADValue": "3.3VCS", "Callouts": [ 2117 { 2118 "CalloutList": [ 2119 { "Priority": "high", "LocCode": "P0" } 2120 ] 2121 } 2122 ] 2123 }, 2124 { 2125 "ADValue": "1.1V_Current", "Callouts": [ 2126 { 2127 "CalloutList": [ 2128 { "Priority": "high", "LocCode": "P0" } 2129 ] 2130 } 2131 ] 2132 }, 2133 { 2134 "ADValue": "5.0V_USB_Current", "Callouts": [ 2135 { 2136 "CalloutList": [ 2137 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2138 { "Priority": "medium", "LocCode": "P0" } 2139 ] 2140 } 2141 ] 2142 }, 2143 { 2144 "ADValue": "5.0V_DASD_Current", "Callouts": [ 2145 { 2146 "CalloutList": [ 2147 { "Priority": "medium", "LocCode": "P1" }, 2148 { "Priority": "medium", "LocCode": "P2" }, 2149 { "Priority": "medium", "LocCode": "P3" }, 2150 { "Priority": "low", "LocCode": "P0" } 2151 ] 2152 } 2153 ] 2154 }, 2155 { 2156 "ADValue": "12.0VN", "Callouts": [ 2157 { 2158 "CalloutList": [ 2159 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2160 ] 2161 } 2162 ] 2163 }, 2164 { 2165 "ADValue": "12.0VP", "Callouts": [ 2166 { 2167 "CalloutList": [ 2168 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2169 ] 2170 } 2171 ] 2172 }, 2173 { 2174 "ADValue": "12.0VQ", "Callouts": [ 2175 { 2176 "CalloutList": [ 2177 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2178 ] 2179 } 2180 ] 2181 }, 2182 { 2183 "ADValue": "12.0VR", "Callouts": [ 2184 { 2185 "CalloutList": [ 2186 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2187 ] 2188 } 2189 ] 2190 }, 2191 { 2192 "ADValue": "ThermalDiode1", "Callouts": [ 2193 { 2194 "CalloutList": [ 2195 { "Priority": "high", "LocCode": "P0" } 2196 ] 2197 } 2198 ] 2199 }, 2200 { 2201 "ADValue": "ThermalDiode2", "Callouts": [ 2202 { 2203 "CalloutList": [ 2204 { "Priority": "high", "LocCode": "P0" } 2205 ] 2206 } 2207 ] 2208 }, 2209 { 2210 "ADValue": "ThermalDiode3", "Callouts": [ 2211 { 2212 "CalloutList": [ 2213 { "Priority": "high", "LocCode": "P0" } 2214 ] 2215 } 2216 ] 2217 }, 2218 { 2219 "ADValue": "ThermalDiode4", "Callouts": [ 2220 { 2221 "CalloutList": [ 2222 { "Priority": "high", "LocCode": "P0" } 2223 ] 2224 } 2225 ] 2226 } 2227 ] 2228 }, 2229 2230 "Documentation": { 2231 "Description": "The power sequencer chip detected a voltage fault", 2232 "Message": "The power sequencer chip detected a voltage fault", 2233 "Notes": [ 2234 ] 2235 } 2236 }, 2237 2238 { 2239 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 2240 "Subsystem": "power", 2241 "Severity": "predictive_redundancy_loss", 2242 "ComponentID": "0x2700", 2243 2244 "SRC": { 2245 "Type": "11", 2246 "ReasonCode": "0x2700", 2247 "Words6To9": {} 2248 }, 2249 2250 "Documentation": { 2251 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 2252 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 2253 "Notes": [ 2254 "CALLOUT_INVENTORY_PATH should be specified in the ", 2255 "AdditionalData property of the event log so that ", 2256 "the device is called out but not the communication path." 2257 ] 2258 } 2259 }, 2260 2261 { 2262 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 2263 "Subsystem": "power", 2264 "Severity": "non_error", 2265 "MfgSeverity": "predictive_redundancy_loss", 2266 "ActionFlags": ["report"], 2267 "MfgActionFlags": ["service_action", "report", "call_home"], 2268 "ComponentID": "0x2700", 2269 2270 "SRC": { 2271 "Type": "11", 2272 "ReasonCode": "0x2701", 2273 "Words6To9": {} 2274 }, 2275 2276 "Documentation": { 2277 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 2278 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 2279 "Notes": [ 2280 "CALLOUT_INVENTORY_PATH should be specified in the ", 2281 "AdditionalData property of the event log so that ", 2282 "the device is called out but not the communication path." 2283 ] 2284 } 2285 }, 2286 2287 { 2288 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 2289 "Subsystem": "power", 2290 "ComponentID": "0x2700", 2291 2292 "SRC": { 2293 "Type": "11", 2294 "ReasonCode": "0x2900", 2295 "Words6To9": {} 2296 }, 2297 2298 "Documentation": { 2299 "Description": "A write verification error occurred on a device", 2300 "Message": "A write verification error occurred on a device", 2301 "Notes": [ 2302 "This error occurs when a device register is written, ", 2303 "read back, and the two values do not match. This is ", 2304 "also called a read-back error. The device should be ", 2305 "identified using the CALLOUT_DEVICE_PATH or ", 2306 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 2307 "AdditionalData property of the event log. This will ", 2308 "cause the device and the hardware in the communication ", 2309 "path to be called out." 2310 ] 2311 } 2312 }, 2313 2314 { 2315 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Discharging", 2316 "Subsystem": "power", 2317 "Severity": "non_error", 2318 "ActionFlags": ["report"], 2319 "ComponentID": "0x2700", 2320 2321 "SRC": { 2322 "Type": "11", 2323 "ReasonCode": "0x4201", 2324 "Words6To9": {} 2325 }, 2326 2327 "Documentation": { 2328 "Description": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 2329 "Message": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 2330 "Notes": [ 2331 ] 2332 } 2333 }, 2334 2335 { 2336 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Low", 2337 "Subsystem": "power", 2338 "Severity": "non_error", 2339 "ActionFlags": ["report"], 2340 "ComponentID": "0x2700", 2341 2342 "SRC": { 2343 "Type": "11", 2344 "ReasonCode": "0x4203", 2345 "Words6To9": {} 2346 }, 2347 2348 "Documentation": { 2349 "Description": "The Uninterruptible Power Supply (UPS) battery level is low", 2350 "Message": "The Uninterruptible Power Supply (UPS) battery level is low", 2351 "Notes": [ 2352 ] 2353 } 2354 }, 2355 2356 { 2357 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 2358 "Subsystem": "power", 2359 "ComponentID": "0x2700", 2360 2361 "SRC": { 2362 "Type": "11", 2363 "ReasonCode": "0xA013", 2364 "Words6To9": {} 2365 }, 2366 2367 "Callouts": [ 2368 { 2369 "CalloutList": [ 2370 { "Priority": "high", "Procedure": "bmc_code" } 2371 ] 2372 } 2373 ], 2374 2375 "Documentation": { 2376 "Description": "A regulators configuration file error occurred", 2377 "Message": "A regulators configuration file error occurred", 2378 "Notes": [ 2379 "The regulators configuration file could not be found, ", 2380 "could not be read, or had invalid contents." 2381 ] 2382 } 2383 }, 2384 2385 { 2386 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 2387 "Subsystem": "power", 2388 "Severity": "critical_system_term", 2389 "ComponentID": "0x2700", 2390 2391 "SRC": { 2392 "Type": "11", 2393 "ReasonCode": "0xA014", 2394 "Words6To9": {}, 2395 "PowerFault": true 2396 }, 2397 2398 "Callouts": [ 2399 { 2400 "CalloutList": [ 2401 { "Priority": "high", "Procedure": "bmc_code" } 2402 ] 2403 } 2404 ], 2405 2406 "Documentation": { 2407 "Description": "A critical regulators configuration file error occurred", 2408 "Message": "A critical regulators configuration file error occurred", 2409 "Notes": [ 2410 "The regulators configuration file could not be found, ", 2411 "could not be read, or had invalid contents. As a result ", 2412 "voltage regulators could not be configured, and the ", 2413 "chassis could not be powered on." 2414 ] 2415 } 2416 }, 2417 2418 { 2419 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 2420 "Subsystem": "power_sequencer", 2421 "ComponentID": "0x2700", 2422 2423 "SRC": { 2424 "Type": "11", 2425 "ReasonCode": "0xD000", 2426 "Words6To9": {} 2427 }, 2428 2429 "Callouts": [ 2430 { 2431 "CalloutList": [ 2432 { "Priority": "high", "LocCode": "P0" } 2433 ] 2434 } 2435 ], 2436 2437 "Documentation": { 2438 "Description": "The power sequencer chip detected a fault", 2439 "Message": "The power sequencer chip detected a fault", 2440 "Notes": [ 2441 ] 2442 } 2443 }, 2444 2445 { 2446 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 2447 "Subsystem": "power_sequencer", 2448 "ComponentID": "0x2700", 2449 "Severity": "critical", 2450 2451 "SRC": { 2452 "Type": "11", 2453 "ReasonCode": "0xD002", 2454 "Words6To9": {} 2455 }, 2456 2457 "Callouts": [ 2458 { 2459 "CalloutList": [ 2460 { "Priority": "high", "LocCode": "P0" } 2461 ] 2462 } 2463 ], 2464 2465 "Documentation": { 2466 "Description": "System power failed to turn on within timeout period", 2467 "Message": "System power failed to turn on within timeout period", 2468 "Notes": [ 2469 ] 2470 } 2471 }, 2472 2473 { 2474 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 2475 "Subsystem": "power_sequencer", 2476 "ComponentID": "0x2700", 2477 "Severity": "critical", 2478 2479 "SRC": { 2480 "Type": "11", 2481 "ReasonCode": "0xD008", 2482 "Words6To9": {} 2483 }, 2484 2485 "Callouts": [ 2486 { 2487 "CalloutList": [ 2488 { "Priority": "high", "LocCode": "P0" } 2489 ] 2490 } 2491 ], 2492 2493 "Documentation": { 2494 "Description": "System power failed to turn off within timeout period", 2495 "Message": "System power failed to turn off within timeout period", 2496 "Notes": [ 2497 ] 2498 } 2499 }, 2500 2501 { 2502 "Name": "xyz.openbmc_project.Power.Error.Internal", 2503 "Subsystem": "power", 2504 "ComponentID": "0x2700", 2505 2506 "SRC": { 2507 "Type": "11", 2508 "ReasonCode": "0xE000", 2509 "Words6To9": {} 2510 }, 2511 2512 "Callouts": [ 2513 { 2514 "CalloutList": [ 2515 { "Priority": "high", "Procedure": "bmc_code" } 2516 ] 2517 } 2518 ], 2519 2520 "Documentation": { 2521 "Description": "An internal firmware error occurred", 2522 "Message": "An internal firmware error occurred", 2523 "Notes": [ 2524 "The error details must be provided in the AdditionalData ", 2525 "property of the event log." 2526 ] 2527 } 2528 }, 2529 2530 { 2531 "Name": "xyz.openbmc_project.Power.Error.I2C", 2532 "Subsystem": "cec_i2c", 2533 "ComponentID": "0x2700", 2534 2535 "SRC": { 2536 "Type": "11", 2537 "ReasonCode": "0xE100", 2538 "Words6To9": {} 2539 }, 2540 2541 "Documentation": { 2542 "Description": "An I2C error occurred communicating with a device", 2543 "Message": "An I2C error occurred communicating with a device", 2544 "Notes": [ 2545 "The device should be identified using the ", 2546 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 2547 "keywords in the AdditionalData property of the event ", 2548 "log. This will cause the device and the hardware in the ", 2549 "communication path to be called out." 2550 ] 2551 } 2552 }, 2553 2554 { 2555 "Name": "xyz.openbmc_project.Power.Error.PMBus", 2556 "Subsystem": "power", 2557 "ComponentID": "0x2700", 2558 2559 "SRC": { 2560 "Type": "11", 2561 "ReasonCode": "0xE200", 2562 "Words6To9": {} 2563 }, 2564 2565 "Documentation": { 2566 "Description": "A PMBus error occurred on a device", 2567 "Message": "A PMBus error occurred on a device", 2568 "Notes": [ 2569 "This error occurs when the I2C communication was ", 2570 "successful, but the PMBus value read is invalid or ", 2571 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 2572 "in the AdditionalData property of the event log so that ", 2573 "the device is called out but not the communication path." 2574 ] 2575 } 2576 }, 2577 2578 { 2579 "Name": "xyz.openbmc_project.Power.Error.DBus", 2580 "Subsystem": "power", 2581 "ComponentID": "0x2700", 2582 2583 "SRC": { 2584 "Type": "11", 2585 "ReasonCode": "0xE300", 2586 "Words6To9": {} 2587 }, 2588 2589 "Callouts": [ 2590 { 2591 "CalloutList": [ 2592 { "Priority": "high", "Procedure": "bmc_code" } 2593 ] 2594 } 2595 ], 2596 2597 "Documentation": { 2598 "Description": "A firmware inter-process communication (D-Bus) error occurred", 2599 "Message": "A firmware inter-process communication (D-Bus) error occurred" 2600 } 2601 }, 2602 2603 { 2604 "Name": "xyz.openbmc_project.Fan.Error.Fault", 2605 "Subsystem": "power_fans", 2606 "ComponentID": "0x2800", 2607 2608 "SRC": { 2609 "Type": "11", 2610 "ReasonCode": "0x76F0", 2611 "Words6To9": {} 2612 }, 2613 2614 "Documentation": { 2615 "Description": "Fan rotor fault", 2616 "Message": "Fan rotor fault", 2617 "Notes": [ 2618 "This error occurs when a fan rotor has been faulted for a ", 2619 "certain amount of time. The callout is the fan which is ", 2620 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 2621 "passed in during creation and will be either informational ", 2622 "or unrecoverable. The action flags use the defaults and ", 2623 "vary based on the severity." 2624 ] 2625 } 2626 }, 2627 2628 { 2629 "Name": "xyz.openbmc_project.Fan.Error.Missing", 2630 "Subsystem": "power_fans", 2631 "ComponentID": "0x2800", 2632 "Severity": "unrecoverable_redundancy_loss", 2633 "ActionFlags": ["service_action", "report", "call_home"], 2634 2635 "SRC": { 2636 "Type": "11", 2637 "ReasonCode": "0x76F1", 2638 "Words6To9": {} 2639 }, 2640 2641 "Callouts": [ 2642 { 2643 "System": "ibm,rainier", 2644 "CalloutList": [ 2645 { 2646 "Priority": "high", 2647 "SymbolicFRUTrusted": "air_mover", 2648 "UseInventoryLocCode": true 2649 }, 2650 { 2651 "Priority": "low", 2652 "LocCode": "P0" 2653 } 2654 ] 2655 }, 2656 { 2657 "System": "ibm,everest", 2658 "CalloutList": [ 2659 { 2660 "Priority": "high", 2661 "SymbolicFRUTrusted": "air_mover", 2662 "UseInventoryLocCode": true 2663 }, 2664 { 2665 "Priority": "low", 2666 "LocCode": "P1" 2667 } 2668 ] 2669 } 2670 ], 2671 2672 "Documentation": { 2673 "Description": "A fan is missing", 2674 "Message": "A fan is missing", 2675 "Notes": [ 2676 "This error occurs when a fan has been missing for a ", 2677 "certain amount of time. The first callout is the ", 2678 "symbolic FRU AIR_MOVR that has the trusted fan location ", 2679 "code, which it gets using the passed in ", 2680 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 2681 "where the controller and GPIO expander are." 2682 ] 2683 } 2684 }, 2685 2686 { 2687 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 2688 "ComponentID": "0x2800", 2689 "Subsystem": "power_fans", 2690 "Severity": "non_error", 2691 "ActionFlags": ["report"], 2692 "MfgSeverity": "predictive", 2693 "MfgActionFlags": ["service_action", "report"], 2694 2695 "SRC": { 2696 "Type": "11", 2697 "ReasonCode": "0x76F2", 2698 "Words6To9": {} 2699 }, 2700 2701 "Callouts": [ 2702 { 2703 "System": "ibm,rainier", 2704 "CalloutList": [ 2705 {"Priority": "medium", "LocCode": "P0"} 2706 ] 2707 }, 2708 { 2709 "System": "ibm,everest", 2710 "CalloutList": [ 2711 {"Priority": "medium", "LocCode": "P1"} 2712 ] 2713 } 2714 ], 2715 2716 "Documentation": { 2717 "Description": "Presence detect methods for the same fan disagree", 2718 "Message": "Presence detect methods for the same fan disagree", 2719 "Notes": [ 2720 "This error occurs when there is more than one way to detect", 2721 "fan presence, and they don't all agree. For example, the", 2722 "GPIO says a fan isn't present, but the tach readings are", 2723 "nonzero. This is informational, unless in manufacturing.", 2724 "The fan FRU is passed in as a high priority callout.", 2725 "The FRU the GPIO source is on is called out medium." 2726 ] 2727 } 2728 }, 2729 2730 { 2731 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 2732 "ComponentID": "0x2800", 2733 "Subsystem": "power_fans", 2734 "Severity": "critical_system_term", 2735 "ActionFlags": ["service_action", "report", "call_home"], 2736 2737 "SRC": { 2738 "Type": "11", 2739 "ReasonCode": "0x76F3", 2740 "Words6To9": {}, 2741 "PowerFault": true 2742 }, 2743 2744 "Callouts": [ 2745 { 2746 "System": "ibm,rainier", 2747 "CalloutList": [ 2748 {"Priority": "high", "LocCode": "P0-C5"}, 2749 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 2750 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 2751 {"Priority": "low", "LocCode": "P0"} 2752 ] 2753 }, 2754 { 2755 "System": "ibm,everest", 2756 "CalloutList": [ 2757 {"Priority": "high", "LocCode": "P0-C0"}, 2758 {"Priority": "medium", "LocCode": "P1"}, 2759 {"Priority": "low", "LocCode": "P0"} 2760 ] 2761 } 2762 ], 2763 2764 "Documentation": { 2765 "Description": "The fan controller device is offline", 2766 "Message": "The fan controller is offline. The system must be powered off.", 2767 "Notes": [ 2768 "The device that controls the fans is offline so the fan", 2769 "targets and speeds are unknown. The system will be shut", 2770 "down to preserve thermal safety. There may be an I2C", 2771 "or power problem with the device." 2772 ] 2773 } 2774 }, 2775 2776 { 2777 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 2778 "Subsystem": "power_fans", 2779 "ComponentID": "0x2800", 2780 "Severity": "unrecoverable_redundancy_loss", 2781 "ActionFlags": ["service_action", "report", "call_home"], 2782 2783 "SRC": { 2784 "Type": "11", 2785 "ReasonCode": "0x76F4", 2786 "Words6To9": {} 2787 }, 2788 2789 "Callouts": [ 2790 { 2791 "System" : "ibm,rainier", 2792 "CalloutList": [ 2793 {"Priority": "high", "LocCode": "P0-C5"}, 2794 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 2795 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 2796 {"Priority": "low", "LocCode": "P0"} 2797 ] 2798 }, 2799 { 2800 "System" : "ibm,everest", 2801 "CalloutList": [ 2802 {"Priority": "high", "LocCode": "P0-C0"}, 2803 {"Priority": "medium", "LocCode": "P1"}, 2804 {"Priority": "low", "LocCode": "P0"} 2805 ] 2806 } 2807 ], 2808 2809 "Documentation": { 2810 "Description": "Fan GPIO sensors not present", 2811 "Message": "Fan GPIO sensors not present", 2812 "Notes": [ 2813 "The device that reports fan presence is not functioning." 2814 ] 2815 } 2816 }, 2817 2818 { 2819 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 2820 "Subsystem": "power", 2821 "ComponentID": "0x2800", 2822 "Severity": "predictive", 2823 "ActionFlags": ["service_action", "report"], 2824 2825 "SRC": { 2826 "ReasonCode": "0x2801", 2827 "Words6To9": {} 2828 }, 2829 2830 "CalloutsUsingAD": { 2831 "ADName": "SENSOR_NAME", 2832 "CalloutsWithTheirADValues": [ 2833 { 2834 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2835 "Callouts": [ 2836 { 2837 "CalloutList": [ 2838 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2839 ] 2840 } 2841 ] 2842 } 2843 ] 2844 }, 2845 2846 "Documentation": { 2847 "Description": "A temperature sensor exceeded its performance loss threshold.", 2848 "Message": "A temperature sensor exceeded its performance loss threshold.", 2849 "Notes": [ 2850 "A temperature sensor crossed its performance loss threshold value", 2851 "If it is the ambient sensor, then a symbolic FRU will be added.", 2852 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2853 "a FRU callout." 2854 ] 2855 } 2856 }, 2857 2858 { 2859 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 2860 "Subsystem": "power", 2861 "ComponentID": "0x2800", 2862 "Severity": "non_error", 2863 "ActionFlags": ["report"], 2864 "EventType": "env_normal", 2865 2866 "SRC": { 2867 "ReasonCode": "0x2802", 2868 "Words6To9": {} 2869 }, 2870 2871 "CalloutsUsingAD": { 2872 "ADName": "SENSOR_NAME", 2873 "CalloutsWithTheirADValues": [ 2874 { 2875 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2876 "Callouts": [ 2877 { 2878 "CalloutList": [ 2879 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2880 ] 2881 } 2882 ] 2883 } 2884 ] 2885 }, 2886 2887 "Documentation": { 2888 "Description": "A temperature sensor is under its performance loss threshold.", 2889 "Message": "A temperature sensor is under its performance loss threshold.", 2890 "Notes": [ 2891 "A temperature sensor crossed under its performance loss threshold value", 2892 "If it is the ambient sensor, then a symbolic FRU will be added." 2893 ] 2894 } 2895 }, 2896 2897 { 2898 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 2899 "Subsystem": "power", 2900 "ComponentID": "0x2800", 2901 "Severity": "predictive", 2902 "ActionFlags": ["service_action", "report"], 2903 2904 "SRC": { 2905 "ReasonCode": "0x2803", 2906 "Words6To9": {} 2907 }, 2908 2909 "CalloutsUsingAD": { 2910 "ADName": "SENSOR_NAME", 2911 "CalloutsWithTheirADValues": [ 2912 { 2913 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2914 "Callouts": [ 2915 { 2916 "CalloutList": [ 2917 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2918 ] 2919 } 2920 ] 2921 } 2922 ] 2923 }, 2924 2925 "Documentation": { 2926 "Description": "A temperature sensor exceeded its warning threshold.", 2927 "Message": "A temperature sensor exceeded its warning threshold.", 2928 "Notes": [ 2929 "A temperature sensor crossed its warning threshold value", 2930 "If it is the ambient sensor, then a symbolic FRU will be added.", 2931 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2932 "a FRU callout." 2933 ] 2934 } 2935 }, 2936 2937 { 2938 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 2939 "Subsystem": "power", 2940 "ComponentID": "0x2800", 2941 "Severity": "non_error", 2942 "ActionFlags": ["report"], 2943 "EventType": "env_normal", 2944 2945 "SRC": { 2946 "ReasonCode": "0x2804", 2947 "Words6To9": {} 2948 }, 2949 2950 "CalloutsUsingAD": { 2951 "ADName": "SENSOR_NAME", 2952 "CalloutsWithTheirADValues": [ 2953 { 2954 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2955 "Callouts": [ 2956 { 2957 "CalloutList": [ 2958 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2959 ] 2960 } 2961 ] 2962 } 2963 ] 2964 }, 2965 2966 "Documentation": { 2967 "Description": "A temperature sensor is under its warning threshold.", 2968 "Message": "A temperature sensor is under its warning threshold.", 2969 "Notes": [ 2970 "A temperature sensor crossed under its warning threshold value", 2971 "If it is the ambient sensor, then a symbolic FRU will be added." 2972 ] 2973 } 2974 }, 2975 2976 { 2977 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 2978 "Subsystem": "power", 2979 "ComponentID": "0x2800", 2980 "Severity": "predictive", 2981 "ActionFlags": ["service_action", "report"], 2982 2983 "SRC": { 2984 "ReasonCode": "0x2805", 2985 "Words6To9": {} 2986 }, 2987 2988 "CalloutsUsingAD": { 2989 "ADName": "SENSOR_NAME", 2990 "CalloutsWithTheirADValues": [ 2991 { 2992 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2993 "Callouts": [ 2994 { 2995 "CalloutList": [ 2996 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2997 ] 2998 } 2999 ] 3000 } 3001 ] 3002 }, 3003 3004 "Documentation": { 3005 "Description": "A temperature sensor exceeded its critical threshold.", 3006 "Message": "A temperature sensor exceeded its critical threshold.", 3007 "Notes": [ 3008 "A temperature sensor crossed its critical threshold value", 3009 "If it is the ambient sensor, then a symbolic FRU will be added.", 3010 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3011 "a FRU callout." 3012 ] 3013 } 3014 }, 3015 3016 { 3017 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 3018 "Subsystem": "power", 3019 "ComponentID": "0x2800", 3020 "Severity": "non_error", 3021 "ActionFlags": ["report"], 3022 "EventType": "env_normal", 3023 3024 "SRC": { 3025 "ReasonCode": "0x2806", 3026 "Words6To9": {} 3027 }, 3028 3029 "CalloutsUsingAD": { 3030 "ADName": "SENSOR_NAME", 3031 "CalloutsWithTheirADValues": [ 3032 { 3033 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3034 "Callouts": [ 3035 { 3036 "CalloutList": [ 3037 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3038 ] 3039 } 3040 ] 3041 } 3042 ] 3043 }, 3044 3045 "Documentation": { 3046 "Description": "A temperature sensor is under its critical threshold.", 3047 "Message": "A temperature sensor is under its critical threshold.", 3048 "Notes": [ 3049 "A temperature sensor crossed under its critical threshold value", 3050 "If it is the ambient sensor, then a symbolic FRU will be added." 3051 ] 3052 } 3053 }, 3054 3055 { 3056 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 3057 "Subsystem": "power", 3058 "ComponentID": "0x2800", 3059 "Severity": "predictive", 3060 "ActionFlags": ["service_action", "report"], 3061 3062 "SRC": { 3063 "ReasonCode": "0x2807", 3064 "Words6To9": {} 3065 }, 3066 3067 "Callouts": [ 3068 { 3069 "CalloutList": [ 3070 { 3071 "Priority": "high", 3072 "SymbolicFRU": "ambient_temp" 3073 } 3074 ] 3075 } 3076 ], 3077 3078 "Documentation": { 3079 "Description": "The ambient temperature passed the EPOW3 limit.", 3080 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 3081 "Notes": [ 3082 "This error occurs when the ambient temperature surpassed", 3083 "the EPOW3 shutdown limit." 3084 ] 3085 } 3086 }, 3087 3088 { 3089 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 3090 "Subsystem": "power", 3091 "ComponentID": "0x2800", 3092 "Severity": "non_error", 3093 "ActionFlags": ["report"], 3094 "EventType": "env_normal", 3095 3096 "SRC": { 3097 "ReasonCode": "0x2808", 3098 "Words6To9": {} 3099 }, 3100 3101 "Callouts": [ 3102 { 3103 "CalloutList": [ 3104 { 3105 "Priority": "high", 3106 "SymbolicFRU": "ambient_temp_back" 3107 } 3108 ] 3109 } 3110 ], 3111 3112 "Documentation": { 3113 "Description": "The ambient temperature is back under the EPOW3 limit.", 3114 "Message": "The ambient temperature is back under the EPOW3 limit." 3115 } 3116 }, 3117 3118 { 3119 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 3120 "Subsystem": "power", 3121 "ComponentID": "0x2800", 3122 "ActionFlags": ["service_action", "report"], 3123 3124 "SRC": { 3125 "ReasonCode": "0x2809", 3126 "Words6To9": {} 3127 }, 3128 3129 "Callouts": [ 3130 { 3131 "CalloutList": [ 3132 { 3133 "Priority": "high", 3134 "SymbolicFRU": "ambient_temp" 3135 } 3136 ] 3137 } 3138 ], 3139 3140 "Documentation": { 3141 "Description": "The ambient temperature passed the EPOW4 limit.", 3142 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 3143 "Notes": [ 3144 "This error occurs when the ambient temperature surpassed", 3145 "the EPOW4 shutdown limit." 3146 ] 3147 } 3148 }, 3149 3150 { 3151 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 3152 "Subsystem": "ext_env", 3153 "ComponentID": "0x2800", 3154 "Severity": "predictive", 3155 "ActionFlags": ["service_action", "report"], 3156 3157 "SRC": { 3158 "ReasonCode": "0x280A", 3159 "Words6To9": {} 3160 }, 3161 3162 "CalloutsUsingAD": { 3163 "ADName": "SENSOR_NAME", 3164 "CalloutsWithTheirADValues": [ 3165 { 3166 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 3167 "Callouts": [ 3168 { 3169 "CalloutList": [ 3170 { "Priority": "high", "SymbolicFRU": "altitude" } 3171 ] 3172 } 3173 ] 3174 } 3175 ] 3176 }, 3177 3178 "Documentation": { 3179 "Description": "An altitude sensor exceeded its warning threshold.", 3180 "Message": "An altitude sensor exceeded its warning threshold.", 3181 "Notes": [ 3182 "The virtual altitude sensor crossed its warning threshold value", 3183 " and a symbolic FRU will be added." 3184 ] 3185 } 3186 }, 3187 3188 { 3189 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 3190 "Subsystem": "ext_env", 3191 "ComponentID": "0x2800", 3192 "Severity": "non_error", 3193 "ActionFlags": ["report"], 3194 "EventType": "env_normal", 3195 3196 "SRC": { 3197 "ReasonCode": "0x280B", 3198 "Words6To9": {} 3199 }, 3200 3201 "Documentation": { 3202 "Description": "An altitude sensor is under its warning threshold.", 3203 "Message": "An altitude sensor is under its warning threshold.", 3204 "Notes": [ 3205 "The virtual altitude sensor is under its warning threshold value", 3206 " and a symbolic FRU will be added." 3207 ] 3208 } 3209 }, 3210 3211 { 3212 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 3213 "Subsystem": "cec_tod", 3214 "ComponentID": "0x2800", 3215 "Severity": "predictive", 3216 "ActionFlags": ["service_action", "report"], 3217 3218 "SRC": { 3219 "ReasonCode": "0x280C", 3220 "Words6To9": {} 3221 }, 3222 3223 "CalloutsUsingAD": { 3224 "ADName": "SENSOR_NAME", 3225 "CalloutsWithTheirADValues": [ 3226 { 3227 "ADValue": "/xyz/openbmc_project/sensors/voltage/Battery_Voltage", 3228 "Callouts": [ 3229 { 3230 "System": "ibm,rainier", 3231 "CalloutList": [ 3232 { 3233 "Priority": "high", 3234 "LocCode": "P0-E0" 3235 } 3236 ] 3237 }, 3238 { 3239 "System": "ibm,everest", 3240 "CalloutList": [ 3241 { 3242 "Priority": "high", 3243 "LocCode": "P0-C0-E0" 3244 } 3245 ] 3246 } 3247 ] 3248 } 3249 ] 3250 }, 3251 3252 "Documentation": { 3253 "Description": "A voltage sensor went below its critical low threshold.", 3254 "Message": "A voltage sensor went below its critical low threshold." 3255 } 3256 }, 3257 3258 { 3259 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 3260 "Subsystem": "cec_tod", 3261 "ComponentID": "0x2800", 3262 "Severity": "non_error", 3263 "ActionFlags": ["report"], 3264 3265 "SRC": { 3266 "ReasonCode": "0x280D", 3267 "Words6To9": {} 3268 }, 3269 3270 "Documentation": { 3271 "Description": "A voltage sensor is over its critical low threshold.", 3272 "Message": "A voltage sensor is over its critical low threshold." 3273 } 3274 }, 3275 3276 { 3277 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLow", 3278 "Subsystem": "power", 3279 "ComponentID": "0x2800", 3280 "Severity": "predictive", 3281 "ActionFlags": ["service_action", "report"], 3282 3283 "SRC": { 3284 "ReasonCode": "0x280E", 3285 "Words6To9": {} 3286 }, 3287 3288 "Documentation": { 3289 "Description": "A temperature sensor is under its low warning threshold.", 3290 "Message": "A temperature sensor is under its low warning threshold.", 3291 "Notes": [ 3292 "A temperature sensor crossed its low warning threshold value", 3293 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 3294 ] 3295 } 3296 }, 3297 3298 { 3299 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLowClear", 3300 "Subsystem": "power", 3301 "ComponentID": "0x2800", 3302 "Severity": "non_error", 3303 "ActionFlags": ["report"], 3304 "EventType": "env_normal", 3305 3306 "SRC": { 3307 "ReasonCode": "0x280F", 3308 "Words6To9": {} 3309 }, 3310 3311 "Documentation": { 3312 "Description": "A temperature sensor is above its low warning threshold.", 3313 "Message": "A temperature sensor is above its low warning threshold.", 3314 "Notes": [ 3315 "A temperature sensor crossed above its low warning threshold value." 3316 ] 3317 } 3318 }, 3319 3320 { 3321 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLow", 3322 "Subsystem": "power", 3323 "ComponentID": "0x2800", 3324 "Severity": "predictive", 3325 "ActionFlags": ["service_action", "report"], 3326 3327 "SRC": { 3328 "ReasonCode": "0x2810", 3329 "Words6To9": {} 3330 }, 3331 3332 "Documentation": { 3333 "Description": "A temperature sensor is under its low critical threshold.", 3334 "Message": "A temperature sensor is under its low critical threshold.", 3335 "Notes": [ 3336 "A temperature sensor crossed its low critical threshold value", 3337 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 3338 ] 3339 } 3340 }, 3341 3342 { 3343 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLowClear", 3344 "Subsystem": "power", 3345 "ComponentID": "0x2800", 3346 "Severity": "non_error", 3347 "ActionFlags": ["report"], 3348 "EventType": "env_normal", 3349 3350 "SRC": { 3351 "ReasonCode": "0x2811", 3352 "Words6To9": {} 3353 }, 3354 3355 "Documentation": { 3356 "Description": "A temperature sensor is over its low critical threshold.", 3357 "Message": "A temperature sensor is over its low critical threshold.", 3358 "Notes": [ 3359 "A temperature sensor crossed above its critical threshold value" 3360 ] 3361 } 3362 }, 3363 3364 { 3365 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 3366 "Subsystem": "cec_vpd", 3367 "ComponentID": "0x4000", 3368 3369 "SRC": { 3370 "ReasonCode": "0x4000", 3371 "Words6To9": 3372 { 3373 "6": 3374 { 3375 "Description": "Errno of the failure.", 3376 "AdditionalDataPropSource": "CALLOUT_ERRNO" 3377 } 3378 } 3379 }, 3380 3381 "Documentation": { 3382 "Description": "A path access error ocurred", 3383 "Message": "An EEPROM path access error occurred.", 3384 "Notes": [ 3385 "This error occurs when parser is unable to access", 3386 "EEPROM path. Errno and device path are captured as", 3387 "additional data." 3388 ] 3389 } 3390 }, 3391 3392 { 3393 "Name": "com.ibm.VPD.Error.InvalidVPD", 3394 "Subsystem": "cec_vpd", 3395 "ComponentID": "0x4000", 3396 3397 "SRC": { 3398 "ReasonCode": "0x4001", 3399 "Words6To9": 3400 { 3401 } 3402 }, 3403 3404 "Documentation": { 3405 "Description": "Invalid VPD data.", 3406 "Message": "A VPD data exception occurred.", 3407 "Notes": [ 3408 "This error occurs when VPD data is found to be", 3409 "invalid. This can be when VPD file is missing out", 3410 "mandatory records.Inventory path is captured in", 3411 "additional data." 3412 ] 3413 } 3414 }, 3415 3416 { 3417 "Name": "com.ibm.VPD.Error.EccCheckFailed", 3418 "Subsystem": "cec_vpd", 3419 "ComponentID": "0x4000", 3420 3421 "SRC": { 3422 "ReasonCode": "0x4002", 3423 "Words6To9": 3424 { 3425 } 3426 }, 3427 3428 "Documentation": { 3429 "Description": "Invalid VPD ecc data.", 3430 "Message": "A VPD ecc exception occurred.", 3431 "Notes": [ 3432 "This error occurs when VPD ecc check fails for the FRU.", 3433 "Inventory path for the failed FRU is captured in additonal", 3434 "data." 3435 ] 3436 } 3437 }, 3438 3439 { 3440 "Name": "com.ibm.VPD.Error.InvalidJson", 3441 "Subsystem": "cec_vpd", 3442 "ComponentID": "0x4000", 3443 3444 "SRC": { 3445 "ReasonCode": "0x4003", 3446 "Words6To9": 3447 { 3448 } 3449 }, 3450 3451 "Callouts": [ 3452 { 3453 "CalloutList": [ 3454 { "Priority": "high", "Procedure": "bmc_code" } 3455 ] 3456 } 3457 ], 3458 3459 "Documentation": { 3460 "Description": "Invalid Json", 3461 "Message": "A Json failure occurred.", 3462 "Notes": [ 3463 "This error occurs when parser fails to access", 3464 "Json file or there is any issue with Json data.", 3465 "Failed Json path and cause of failure is captured", 3466 "in additional data." 3467 ] 3468 } 3469 }, 3470 3471 { 3472 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 3473 "Subsystem": "cec_vpd", 3474 "ComponentID": "0x4000", 3475 3476 "SRC": { 3477 "ReasonCode": "0x4004", 3478 "Words6To9": 3479 { 3480 } 3481 }, 3482 3483 "Documentation": { 3484 "Description": "System VPD restore failed", 3485 "Message": "A system VPD restoration error occurred.", 3486 "Notes": [ 3487 "This error occurs when restoring of system VPD fails.", 3488 "The FRU path and reason for failure is captured in", 3489 "additional data." 3490 ] 3491 } 3492 }, 3493 3494 { 3495 "Name": "com.ibm.VPD.Error.DbusFailure", 3496 "Subsystem": "cec_vpd", 3497 "ComponentID": "0x4000", 3498 3499 "SRC": { 3500 "ReasonCode": "0x4005", 3501 "Words6To9": 3502 { 3503 } 3504 }, 3505 3506 "Callouts": [ 3507 { 3508 "CalloutList": [ 3509 { "Priority": "high", "Procedure": "bmc_code" } 3510 ] 3511 } 3512 ], 3513 3514 "Documentation": { 3515 "Description": "Dbus exception", 3516 "Message": "A Dbus internal error occurred.", 3517 "Notes": [ 3518 "This error occurs when Dbus operation fails.", 3519 "Exceptions details are captured in additonal", 3520 "data." 3521 ] 3522 } 3523 }, 3524 3525 { 3526 "Name": "com.ibm.VPD.Error.UnknownSystemType", 3527 "Subsystem": "cec_vpd", 3528 "ComponentID": "0x4000", 3529 3530 "SRC": { 3531 "ReasonCode": "0x4006", 3532 "Words6To9": 3533 { 3534 } 3535 }, 3536 3537 "Callouts": [ 3538 { 3539 "CalloutList": [ 3540 { "Priority": "high", "LocCode": "P0" } 3541 ] 3542 } 3543 ], 3544 3545 "Documentation": { 3546 "Description": "Unknown System Type", 3547 "Message": "System type not supported in DTB table.", 3548 "Notes": [ 3549 "System type comes from combination of HW and IM value of system VPD.", 3550 "If anything gets changed in that combination, then it can't determine", 3551 "the appropriate DTB for that system. Need to check HW and IM keywords." 3552 ] 3553 } 3554 }, 3555 3556 { 3557 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 3558 "Subsystem": "cec_sp_hostboot_iface", 3559 3560 "SRC": 3561 { 3562 "ReasonCode": "0xC101", 3563 "Words6To9": 3564 { 3565 } 3566 }, 3567 3568 "Documentation": 3569 { 3570 "Description": "Host did not respond within the watchdog timeout interval", 3571 "Message": "Host did not respond before the watchdog timeout interval expired", 3572 "Notes": [ 3573 "Host did not respond before the expiry of the watchdog timeout interval.", 3574 "Collecting hostboot dump." 3575 ] 3576 } 3577 }, 3578 3579 { 3580 "Name": "xyz.openbmc_project.Software.Version.Error.Incompatible", 3581 "Subsystem": "bmc_firmware", 3582 "ComponentID": "0x3600", 3583 "SRC": 3584 { 3585 "ReasonCode": "0x3601", 3586 "Words6To9": 3587 { 3588 } 3589 }, 3590 3591 "Callouts": [ 3592 { 3593 "CalloutList": [ 3594 { "Priority": "high", "Procedure": "bmc_code" } 3595 ] 3596 } 3597 ], 3598 3599 "Documentation": 3600 { 3601 "Description": "A system component has a software version that is incompatible.", 3602 "Message": "A system component has a software version that is incompatible." 3603 } 3604 }, 3605 3606 { 3607 "Name": "xyz.openbmc_project.Software.Version.Error.AlreadyExists", 3608 "Subsystem": "bmc_firmware", 3609 "ComponentID": "0x3600", 3610 "SRC": 3611 { 3612 "ReasonCode": "0x3602", 3613 "Words6To9": 3614 { 3615 } 3616 }, 3617 3618 "Callouts": [ 3619 { 3620 "CalloutList": [ 3621 { "Priority": "high", "Procedure": "bmc_code" } 3622 ] 3623 } 3624 ], 3625 3626 "Documentation": 3627 { 3628 "Description": "This image version already exists on the device.", 3629 "Message": "This image version already exists on the device." 3630 } 3631 }, 3632 3633 { 3634 "Name": "xyz.openbmc_project.Software.Image.Error.UnTarFailure", 3635 "Subsystem": "bmc_firmware", 3636 "ComponentID": "0x3600", 3637 "SRC": 3638 { 3639 "ReasonCode": "0x3603", 3640 "Words6To9": 3641 { 3642 } 3643 }, 3644 3645 "Callouts": [ 3646 { 3647 "CalloutList": [ 3648 { "Priority": "high", "Procedure": "bmc_code" } 3649 ] 3650 } 3651 ], 3652 3653 "Documentation": 3654 { 3655 "Description": "An error occurred during untar.", 3656 "Message": "An error occurred during untar." 3657 } 3658 }, 3659 3660 { 3661 "Name": "xyz.openbmc_project.Software.Image.Error.ManifestFileFailure", 3662 "Subsystem": "bmc_firmware", 3663 "ComponentID": "0x3600", 3664 "SRC": 3665 { 3666 "ReasonCode": "0x3604", 3667 "Words6To9": 3668 { 3669 } 3670 }, 3671 3672 "Callouts": [ 3673 { 3674 "CalloutList": [ 3675 { "Priority": "high", "Procedure": "bmc_code" } 3676 ] 3677 } 3678 ], 3679 3680 "Documentation": 3681 { 3682 "Description": "An error when reading the Manifest file..", 3683 "Message": "An error when reading the Manifest file.." 3684 } 3685 }, 3686 3687 { 3688 "Name": "xyz.openbmc_project.Software.Image.Error.InternalFailure", 3689 "Subsystem": "bmc_firmware", 3690 "ComponentID": "0x3600", 3691 "SRC": 3692 { 3693 "ReasonCode": "0x3605", 3694 "Words6To9": 3695 { 3696 } 3697 }, 3698 3699 "Callouts": [ 3700 { 3701 "CalloutList": [ 3702 { "Priority": "high", "Procedure": "bmc_code" } 3703 ] 3704 } 3705 ], 3706 3707 "Documentation": 3708 { 3709 "Description": "The operation failed internally during processing the image.", 3710 "Message": "The operation failed internally during processing the image." 3711 } 3712 }, 3713 3714 { 3715 "Name": "xyz.openbmc_project.Software.Image.Error.ImageFailure", 3716 "Subsystem": "bmc_firmware", 3717 "ComponentID": "0x3600", 3718 "SRC": 3719 { 3720 "ReasonCode": "0x3606", 3721 "Words6To9": 3722 { 3723 } 3724 }, 3725 3726 "Callouts": [ 3727 { 3728 "CalloutList": [ 3729 { "Priority": "high", "Procedure": "bmc_code" } 3730 ] 3731 } 3732 ], 3733 3734 "Documentation": 3735 { 3736 "Description": "An error occurred processing the image.", 3737 "Message": "An error occurred processing the image." 3738 } 3739 }, 3740 3741 { 3742 "Name": "xyz.openbmc_project.Software.Image.Error.BusyFailure", 3743 "Subsystem": "bmc_firmware", 3744 "ComponentID": "0x3600", 3745 "SRC": 3746 { 3747 "ReasonCode": "0x3607", 3748 "Words6To9": 3749 { 3750 } 3751 }, 3752 3753 "Callouts": [ 3754 { 3755 "CalloutList": [ 3756 { "Priority": "high", "Procedure": "bmc_code" } 3757 ] 3758 } 3759 ], 3760 3761 "Documentation": 3762 { 3763 "Description": "The device is busy during the update.", 3764 "Message": "The device is busy during the update." 3765 } 3766 } 3767 3768 ] 3769} 3770