1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 "Severity": "non_error", 8 9 "SRC": 10 { 11 "ReasonCode": "0x1001", 12 "Words6To9": 13 { 14 "6": 15 { 16 "Description": "Timeout in ms", 17 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 18 } 19 } 20 }, 21 22 "Documentation": 23 { 24 "Description": "This is a generic timeout error", 25 "Message": "An operation timed out", 26 "Notes": [ 27 "The journal should contain more information" 28 ] 29 } 30 }, 31 32 { 33 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 34 "Subsystem": "bmc_firmware", 35 "Severity": "non_error", 36 37 "SRC": 38 { 39 "ReasonCode": "0x1002", 40 "Words6To9": 41 { 42 } 43 }, 44 45 "Documentation": 46 { 47 "Description": "BMC code had a generic internal failure", 48 "Message": "An application had an internal failure", 49 "Notes": [ 50 "The journal should contain more information" 51 ] 52 } 53 }, 54 55 { 56 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 57 "Subsystem": "user_error", 58 "Severity": "non_error", 59 60 "SRC": 61 { 62 "ReasonCode": "0x1003", 63 "Words6To9": 64 { 65 } 66 }, 67 68 "Documentation": 69 { 70 "Description": "BMC code was given an invalid argument", 71 "Message": "Code was given an invalid argument", 72 "Notes": [ 73 "The journal should contain more information" 74 ] 75 } 76 }, 77 { 78 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 79 "Subsystem": "user_error", 80 "Severity": "non_error", 81 82 "SRC": 83 { 84 "ReasonCode": "0x1004", 85 "Words6To9": 86 { 87 } 88 }, 89 90 "Documentation": 91 { 92 "Description": "An operation failed due to insufficient permission", 93 "Message": "An operation failed due to unsufficient permission", 94 "Notes": [ 95 "The journal should contain more information" 96 ] 97 } 98 }, 99 100 { 101 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 102 "Subsystem": "user_error", 103 "Severity": "non_error", 104 105 "SRC": 106 { 107 "ReasonCode": "0x1005", 108 "Words6To9": 109 { 110 } 111 }, 112 113 "Documentation": 114 { 115 "Description": "An operation failed because it isn't allowed", 116 "Message": "An operation failed because it isn't allowed", 117 "Notes": [ 118 "The journal should contain more information" 119 ] 120 } 121 }, 122 123 { 124 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 125 "Subsystem": "user_error", 126 "Severity": "non_error", 127 128 "SRC": 129 { 130 "ReasonCode": "0x1006", 131 "Words6To9": 132 { 133 } 134 }, 135 136 "Documentation": 137 { 138 "Description": "The server's CA certificate has not been provided", 139 "Message": "The server's CA certificate has not been provided" 140 } 141 }, 142 143 { 144 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 145 "Subsystem": "cec_i2c", 146 147 "SRC": 148 { 149 "ReasonCode": "0x1007", 150 "Words6To9": 151 { 152 "6": 153 { 154 "Description": "errno of the failure", 155 "AdditionalDataPropSource": "CALLOUT_ERRNO" 156 } 157 } 158 }, 159 160 "Documentation": 161 { 162 "Description": "Sensor device read failure", 163 "Message": "There was a failure when reading a sensor device", 164 "Notes": [ 165 "The severity is set by the creator.", 166 "The action flags are set automatically by the code.", 167 "Callouts added based on CALLOUT_DEVICE_PATH." 168 ] 169 } 170 }, 171 172 { 173 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 174 "Subsystem": "cec_i2c", 175 176 "SRC": 177 { 178 "ReasonCode": "0x1008", 179 "Words6To9": 180 { 181 "6": 182 { 183 "Description": "errno of the failure", 184 "AdditionalDataPropSource": "CALLOUT_ERRNO" 185 } 186 } 187 }, 188 189 "Documentation": 190 { 191 "Description": "Device read failure", 192 "Message": "There was a failure when reading a hardware device", 193 "Notes": [ 194 "The severity is set by the creator.", 195 "The action flags are set automatically by the code.", 196 "Callouts added based on CALLOUT_DEVICE_PATH." 197 ] 198 } 199 }, 200 201 { 202 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 203 "Subsystem": "cec_i2c", 204 205 "SRC": 206 { 207 "ReasonCode": "0x1009", 208 "Words6To9": 209 { 210 "6": 211 { 212 "Description": "errno of the failure", 213 "AdditionalDataPropSource": "CALLOUT_ERRNO" 214 } 215 } 216 }, 217 218 "Documentation": 219 { 220 "Description": "Device write failure", 221 "Message": "There was a failure when writing to a hardware device", 222 "Notes": [ 223 "The severity is set by the creator.", 224 "The action flags are set automatically by the code.", 225 "Callouts added based on CALLOUT_DEVICE_PATH" 226 ] 227 } 228 }, 229 230 { 231 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 232 "Subsystem": "cec_i2c", 233 234 "SRC": 235 { 236 "ReasonCode": "0x100A", 237 "Words6To9": 238 { 239 "6": 240 { 241 "Description": "errno of the failure", 242 "AdditionalDataPropSource": "CALLOUT_ERRNO" 243 } 244 } 245 }, 246 247 "Documentation": 248 { 249 "Description": "Device write failure", 250 "Message": "There was a failure when writing to a hardware device", 251 "Notes": [ 252 "The severity is set by the creator.", 253 "The action flags are set automatically by the code.", 254 "Callouts added based on CALLOUT_DEVICE_PATH" 255 ] 256 } 257 }, 258 259 { 260 "Name": "xyz.openbmc_project.Common.File.Error.Write", 261 "Subsystem": "bmc_firmware", 262 "ComponentID": "0x1000", 263 "SRC": 264 { 265 "ReasonCode": "0x100B", 266 "Words6To9": 267 { 268 } 269 }, 270 271 "Callouts": [ 272 { 273 "CalloutList": [ 274 { "Priority": "high", "Procedure": "bmc_code" } 275 ] 276 } 277 ], 278 279 "Documentation": 280 { 281 "Description": "Failed to write to a file", 282 "Message": "Failed to write to a file", 283 "Notes": [ 284 "The severity is set by the creator.", 285 "The journal should contain more information" 286 ] 287 } 288 }, 289 290 { 291 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 292 "Subsystem": "bmc_firmware", 293 "Severity": "non_error", 294 295 "SRC": 296 { 297 "ReasonCode": "0x2001", 298 "Words6To9": 299 { 300 "6": 301 { 302 "Description": "The bad PEL ID", 303 "AdditionalDataPropSource": "BAD_ID" 304 } 305 } 306 }, 307 308 "Documentation": 309 { 310 "Description": "The BMC sent the host a malformed PEL", 311 "Message": "The BMC sent the host a malformed PEL", 312 "Notes": [ 313 "The host firmware rejected that PEL." 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.BadHostPEL", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2002", 326 "Words6To9": 327 { 328 "6": 329 { 330 "Description": "The PLID of the invalid PEL", 331 "AdditionalDataPropSource": "PLID" 332 }, 333 "7": 334 { 335 "Description": "The corresponding OpenBMC event log ID", 336 "AdditionalDataPropSource": "OBMC_LOG_ID" 337 }, 338 "8": 339 { 340 "Description": "The size of the invalid PEL", 341 "AdditionalDataPropSource": "PEL_SIZE" 342 } 343 } 344 }, 345 346 "Callouts": [ 347 { 348 "CalloutList": [ 349 { "Priority": "high", "Procedure": "bmc_code" } 350 ] 351 } 352 ], 353 354 "Documentation": 355 { 356 "Description": "The host sent the BMC an invalid PEL", 357 "Message": "The host sent the BMC an invalid PEL", 358 "Notes": [ 359 ] 360 } 361 }, 362 363 { 364 "Name": "org.open_power.Logging.Error.TestError1", 365 "Subsystem": "platform_firmware", 366 "Severity": "unrecoverable", 367 368 "SRC": 369 { 370 "ReasonCode": "0x2003", 371 "Words6To9": 372 { 373 } 374 }, 375 376 "Callouts": [ 377 { 378 "CalloutList": [ 379 {"Priority": "high", "Procedure": "bmc_code"}, 380 {"Priority": "medium", "SymbolicFRU": "service_docs"} 381 ] 382 } 383 ], 384 385 "Documentation": 386 { 387 "Description": "An error for testing", 388 "Message": "This is a test error" 389 } 390 }, 391 392 { 393 "Name": "xyz.openbmc_project.Logging.Error.Default", 394 "Subsystem": "other_na", 395 396 "SRC": 397 { 398 "ReasonCode": "0x2004", 399 "Words6To9": 400 { 401 } 402 }, 403 404 "Callouts": [ 405 { 406 "CalloutList": [ 407 { "Priority": "high", "Procedure": "bmc_code" } 408 ] 409 } 410 ], 411 412 "Documentation": 413 { 414 "Description": "This entry is used when no other matching entry is found", 415 "Message": "Unknown (Original event not in message registry)", 416 "Notes": [ 417 "This is used when the actual error name isn't found in ", 418 "the registry. The original error name will be stored ", 419 "in the UserData section that contains the AdditionalData ", 420 "properties using the key ERROR_NAME.", 421 "This error may contain callouts if the creator passed ", 422 "them in.", 423 "The severity is set by the creator.", 424 "If this error is seen, then a code change needs to be ", 425 "made to add the missing error entry to this registry." 426 ] 427 } 428 }, 429 430 { 431 "Name": "org.open_power.Logging.Error.TestError2", 432 "Subsystem": "bmc_firmware", 433 "Severity": "recovered", 434 "ActionFlags": ["report"], 435 436 "SRC": 437 { 438 "ReasonCode": "0x2005", 439 "Words6To9": 440 { 441 } 442 }, 443 444 "Callouts": [ 445 { 446 "CalloutList": [ 447 { "Priority": "high", "LocCode": "P0" } 448 ] 449 } 450 ], 451 452 "Documentation": 453 { 454 "Description": "An error for testing", 455 "Message": "This is a test recoverable error", 456 "Notes": [ 457 "This error is not created by BMC code and is ", 458 "only used for error injection tests." 459 ] 460 } 461 }, 462 463 { 464 "Name": "org.open_power.PHAL.Error.Boot", 465 "Subsystem": "cec_hardware", 466 "ComponentID": "0x3000", 467 468 "SRC": 469 { 470 "ReasonCode": "0x3001", 471 "Words6To9": 472 { 473 } 474 }, 475 476 "Documentation": 477 { 478 "Description": "Failure occurred during boot process", 479 "Message": "Failure occurred during boot process", 480 "Notes": [ 481 "Debug traces will be captured in AdditionalData section" 482 ] 483 } 484 }, 485 486 { 487 "Name": "org.open_power.PHAL.Error.PrePowerOff", 488 "Subsystem": "cec_hardware", 489 "ComponentID": "0x3000", 490 491 "SRC": 492 { 493 "ReasonCode": "0x3002", 494 "Words6To9": 495 { 496 } 497 }, 498 499 "Documentation": 500 { 501 "Description": "Failure occurred during PHAL pre-poweroff operations", 502 "Message": "Failure occurred during PHAL pre-poweroff operations", 503 "Notes": [ 504 "Severity needs to be set based on needs for this registry.", 505 "FFDC (First Failure Data Collection) will be collected ", 506 "and added into PEL." 507 ] 508 } 509 }, 510 511 { 512 "Name": "org.open_power.PHAL.Error.devtreeSync", 513 "Subsystem": "cec_hardware", 514 "ComponentID": "0x3000", 515 "Severity": "unrecoverable", 516 517 "SRC": 518 { 519 "ReasonCode": "0x3003", 520 "Words6To9": 521 { 522 } 523 }, 524 525 "Documentation": 526 { 527 "Description": "Failure occurred during PHAL devtree sync ", 528 "Message": "Failure occurred during PHAL devtree sync", 529 "Notes": [ 530 "The journal should contain more information" 531 ] 532 } 533 }, 534 535 { 536 "Name": "org.open_power.PHAL.Error.devtreeBackup", 537 "Subsystem": "cec_hardware", 538 "ComponentID": "0x3000", 539 "Severity": "unrecoverable", 540 541 "SRC": 542 { 543 "ReasonCode": "0x3004", 544 "Words6To9": 545 { 546 } 547 }, 548 549 "Documentation": 550 { 551 "Description": "Failure occurred during PHAL devtree backup ", 552 "Message": "Failure occurred during PHAL devtree backup", 553 "Notes": [ 554 "The journal should contain more information" 555 ] 556 } 557 }, 558 559 { 560 "Name": "org.open_power.PHAL.Error.HostRunning", 561 "Subsystem": "cec_sp_hyp_iface", 562 "ComponentID": "0x3000", 563 564 "SRC": 565 { 566 "ReasonCode": "0x3005", 567 "Words6To9": 568 { 569 } 570 }, 571 572 "Documentation": 573 { 574 "Description": "Host did not respond to BMC after a BMC reset", 575 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 576 "Notes": [ 577 "System will be left in its current state to ensure host ", 578 "is not unexpectedly taken down. There is most likely an ", 579 "issue in the software or hardware communication path ", 580 "between the BMC and the Host firmware.", 581 "A BMC dump will be collected with relevant FFDC." 582 ] 583 } 584 }, 585 586 { 587 "Name": "org.open_power.PHAL.Error.devtreeReinit", 588 "Subsystem": "cec_hardware", 589 "ComponentID": "0x3000", 590 "Severity": "unrecoverable", 591 592 "SRC": 593 { 594 "ReasonCode": "0x3006", 595 "Words6To9": 596 { 597 } 598 }, 599 600 "Documentation": 601 { 602 "Description": "Failure re-initializing BMC to Host data structure", 603 "Message": "Failure occurred during re-initializing BMC to Host data structure", 604 "Notes": [ 605 "The journal should contain more information" 606 ] 607 } 608 }, 609 610 { 611 "Name": "org.open_power.PHAL.Error.NonFunctionalBootProc", 612 "Subsystem": "cec_hardware", 613 "ComponentID": "0x3000", 614 "Severity": "unrecoverable", 615 616 "SRC": 617 { 618 "ReasonCode": "0x3007", 619 "Words6To9": 620 { 621 } 622 }, 623 624 "Documentation": 625 { 626 "Description": "Non functional boot processor", 627 "Message": "Non functional boot processor", 628 "Notes": [ 629 "BMC firmware couldn't find functional primary processor", 630 "required to boot the host", 631 "Debug traces will be captured in AdditionalData section" 632 ] 633 } 634 }, 635 636 { 637 "Name": "org.open_power.PHAL.Error.MPReboot", 638 "Subsystem": "cec_hardware", 639 "ComponentID": "0x3000", 640 "Severity": "unrecoverable", 641 642 "SRC": 643 { 644 "ReasonCode": "0x3008", 645 "Words6To9": 646 { 647 } 648 }, 649 650 "Callouts": [ 651 { 652 "CalloutList": [{"Priority": "high", "Procedure": "bmc_code" } 653 ] 654 } 655 ], 656 657 "Documentation": 658 { 659 "Description": "Error during memory preserving reboot", 660 "Message": "Error during memory preserving reboot", 661 "Notes": [ 662 "Software error occured during memory preserving reboot" 663 ] 664 } 665 }, 666 667 { 668 "Name": "org.open_power.OCC.Firmware.PresenceMismatch", 669 "Subsystem": "bmc_firmware", 670 "ComponentID": "0x3200", 671 "Severity": "predictive", 672 673 "SRC": 674 { 675 "ReasonCode": "0x3201", 676 "Words6To9": 677 { 678 } 679 }, 680 681 "Callouts": [ 682 { 683 "CalloutList": [ 684 { "Priority": "medium", "Procedure": "bmc_code" } 685 ] 686 } 687 ], 688 689 "Documentation": 690 { 691 "Description": "OCC presence mismatch", 692 "Message": "BMC firmware detected incorrect number of OCCs", 693 "Notes": [ 694 "The number of OCCs detected by the BMC does not match the number of OCCs detected by the OCC.", 695 "The BMC requests that the OCC reset." 696 ] 697 } 698 }, 699 700 { 701 "Name": "org.open_power.OCC.Device.SafeState", 702 "Subsystem": "processor_chip", 703 "ComponentID": "0x3200", 704 "Severity": "non_error", 705 706 "SRC": 707 { 708 "ReasonCode": "0x3202", 709 "Words6To9": 710 { 711 } 712 }, 713 714 "Documentation": 715 { 716 "Description": "OCC safe state", 717 "Message": "OCC in safe state while active for one minute", 718 "Notes": [ 719 "The BMC detected that the OCC was in safe state for one minute while active.", 720 "The BMC requests that the OCC reset." 721 ] 722 } 723 }, 724 725 { 726 "Name": "org.open_power.OCC.Device.ReadFailure", 727 "Subsystem": "cec_chip_iface", 728 "ComponentID": "0x3200", 729 "Severity": "predictive", 730 731 "SRC": 732 { 733 "ReasonCode": "0x3203", 734 "Words6To9": 735 { 736 } 737 }, 738 739 "Documentation": 740 { 741 "Description": "OCC communication failure", 742 "Message": "BMC failed to communicate with the OCC", 743 "Notes": [ 744 "The BMC failed to communicate with the OCC and retried three times.", 745 "The BMC requests that the OCC reset." 746 ] 747 } 748 }, 749 750 { 751 "Name": "org.open_power.HardwareIsolation.Error", 752 "Subsystem": "cec_hardware", 753 "ComponentID": "0x3100", 754 755 "SRC": 756 { 757 "ReasonCode": "0x3101", 758 "Words6To9": 759 { 760 } 761 }, 762 763 "Documentation": 764 { 765 "Description": "Failure occurred during hardware isolation operations", 766 "Message": "Failure occurred during hardware isolation operations", 767 "Notes": [ 768 "Severity needs to be set based on needs for this registry.", 769 "Debug traces will be captured in AdditionalData section" 770 ] 771 } 772 }, 773 774 { 775 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 776 "Subsystem": "cec_sp_hostboot_iface", 777 "ComponentID": "0x3400", 778 "SRC": 779 { 780 "ReasonCode": "0x3401", 781 "Words6To9": 782 { 783 } 784 }, 785 "Documentation": 786 { 787 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 788 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 789 "Notes": [ 790 "System will follow recovery policy, resulting in this ", 791 "error and most likely a a reboot of the host. The issue ", 792 "is most likely the result of the BMC rebooting while the ", 793 "host was booting and in a state where it still needed ", 794 "the BMC to complete its boot." 795 ] 796 } 797 }, 798 799 { 800 "Name": "xyz.openbmc_project.State.ChassisPowerBad", 801 "Subsystem": "input_power_source", 802 "ComponentID": "0x3400", 803 "SRC": 804 { 805 "ReasonCode": "0x3402", 806 "Words6To9": 807 { 808 } 809 }, 810 "Callouts": [ 811 { 812 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 813 } 814 ], 815 "Documentation": 816 { 817 "Description": "Chassis input power is in a bad state", 818 "Message": "Chassis input power is in a bad state, look for other logs with more details", 819 "Notes": [ 820 "The system is most likely in a limited power situation. ", 821 "There is enough power for the BMC to operate but not the ", 822 "CEC hardware. Check for UPS or brownout logs." 823 ] 824 } 825 }, 826 827 { 828 "Name": "xyz.openbmc_project.State.PinholeReset", 829 "Subsystem": "cec_op_panel", 830 "ComponentID": "0x3400", 831 "SRC": 832 { 833 "ReasonCode": "0x3403", 834 "Words6To9": 835 { 836 } 837 }, 838 "Documentation": 839 { 840 "Description": "User initiated a pinhole reset via the op-panel", 841 "Message": "User initiated a pinhole reset via the op-panel", 842 "Notes": [ 843 "This is a notification log to record the fact that a ", 844 "pinhole reset was performed on the BMC, resulting in a ", 845 "hard reset of the BMC." 846 ] 847 } 848 }, 849 850 { 851 "Name": "xyz.openbmc_project.State.Error.CriticalServiceFailure", 852 "Subsystem": "bmc_firmware", 853 "ComponentID": "0x3400", 854 "SRC": 855 { 856 "ReasonCode": "0x3404", 857 "Words6To9": 858 { 859 } 860 }, 861 "Callouts": [ 862 { 863 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 864 } 865 ], 866 "Documentation": 867 { 868 "Description": "A critical BMC application has failed on the system", 869 "Message": "A critical BMC application has failed on the system, the BMC is in an undefined state", 870 "Notes": [ 871 "As a part of generating this error log, a BMC dump has ", 872 "also been generated. Please collect this dump if possible. ", 873 "The BMC state is undefined but basic services could still ", 874 "be available. Usually an AC cycle of the entire system is ", 875 "the best recovery option from this error." 876 ] 877 } 878 }, 879 880 { 881 "Name": "xyz.openbmc_project.State.Error.SecurityCheckFail", 882 "Subsystem": "bmc_firmware", 883 "ComponentID": "0x3400", 884 "SRC": 885 { 886 "ReasonCode": "0x3405", 887 "Words6To9": 888 { 889 } 890 }, 891 "Callouts": [ 892 { 893 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 894 } 895 ], 896 "Documentation": 897 { 898 "Description": "A firmware security check has failed", 899 "Message": "A firmware security check has failed, most likely something is not configured correctly", 900 "Notes": [ 901 "This log is only generated in the manufacturing ", 902 "environment and it indicates that something has not ", 903 "been configured correctly. Use the data in the PEL to ", 904 "determine what that is." 905 ] 906 } 907 }, 908 909 { 910 "Name": "xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure", 911 "Subsystem": "bmc_firmware", 912 "ComponentID": "0x3400", 913 "SRC": 914 { 915 "ReasonCode": "0x3406", 916 "Words6To9": 917 { 918 } 919 }, 920 "Callouts": [ 921 { 922 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 923 } 924 ], 925 "Documentation": 926 { 927 "Description": "The system has failed to reach BMC Ready state", 928 "Message": "The system has failed to reach BMC Ready state, look for other errors", 929 "Notes": [ 930 "This log indicates a critical BMC application required ", 931 "for the BMC to reach Ready state has failed to start ", 932 "successfully. Look in the log for other errors indicating ", 933 "what has failed." 934 ] 935 } 936 }, 937 938 { 939 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOnFailure", 940 "Subsystem": "bmc_firmware", 941 "ComponentID": "0x3400", 942 "SRC": 943 { 944 "ReasonCode": "0x3407", 945 "Words6To9": 946 { 947 } 948 }, 949 "Callouts": [ 950 { 951 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 952 } 953 ], 954 "Documentation": 955 { 956 "Description": "The system has failed to reach chassis power on state", 957 "Message": "The system has failed to reach chassis power on state, look for other errors", 958 "Notes": [ 959 "This log indicates a critical BMC application required ", 960 "for the BMC to power on the chassis has failed to start ", 961 "successfully. Look in the log for other errors indicating ", 962 "what has failed." 963 ] 964 } 965 }, 966 967 { 968 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOffFailure", 969 "Subsystem": "bmc_firmware", 970 "ComponentID": "0x3400", 971 "SRC": 972 { 973 "ReasonCode": "0x3408", 974 "Words6To9": 975 { 976 } 977 }, 978 "Callouts": [ 979 { 980 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 981 } 982 ], 983 "Documentation": 984 { 985 "Description": "The system has failed to reach chassis power off state", 986 "Message": "The system has failed to reach chassis power off state, look for other errors", 987 "Notes": [ 988 "This log indicates a critical BMC application required ", 989 "for the BMC to power off the chassis has failed to start ", 990 "successfully. Look in the log for other errors indicating ", 991 "what has failed." 992 ] 993 } 994 }, 995 996 { 997 "Name": "xyz.openbmc_project.State.Host.Error.HostStartFailure", 998 "Subsystem": "bmc_firmware", 999 "ComponentID": "0x3400", 1000 "SRC": 1001 { 1002 "ReasonCode": "0x3409", 1003 "Words6To9": 1004 { 1005 } 1006 }, 1007 "Callouts": [ 1008 { 1009 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1010 } 1011 ], 1012 "Documentation": 1013 { 1014 "Description": "The system has failed to start the host firmware", 1015 "Message": "The system has failed to start the host firmware, look for other errors", 1016 "Notes": [ 1017 "This log indicates a critical BMC application required ", 1018 "for the BMC to start the host has failed to start ", 1019 "successfully. Look in the log for other errors indicating ", 1020 "what has failed." 1021 ] 1022 } 1023 }, 1024 1025 { 1026 "Name": "xyz.openbmc_project.State.Host.Error.HostStartMinFailure", 1027 "Subsystem": "bmc_firmware", 1028 "ComponentID": "0x3400", 1029 "SRC": 1030 { 1031 "ReasonCode": "0x3410", 1032 "Words6To9": 1033 { 1034 } 1035 }, 1036 "Callouts": [ 1037 { 1038 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1039 } 1040 ], 1041 "Documentation": 1042 { 1043 "Description": "The system has failed to start the host firmware", 1044 "Message": "The system has failed to start the host firmware, look for other errors", 1045 "Notes": [ 1046 "This log indicates a critical BMC application required ", 1047 "for the BMC to start the host has failed to start ", 1048 "successfully. Look in the log for other errors indicating ", 1049 "what has failed." 1050 ] 1051 } 1052 }, 1053 1054 { 1055 "Name": "xyz.openbmc_project.State.Host.Error.HostShutdownFailure", 1056 "Subsystem": "bmc_firmware", 1057 "ComponentID": "0x3400", 1058 "SRC": 1059 { 1060 "ReasonCode": "0x3411", 1061 "Words6To9": 1062 { 1063 } 1064 }, 1065 "Callouts": [ 1066 { 1067 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1068 } 1069 ], 1070 "Documentation": 1071 { 1072 "Description": "The system has failed to shutdown the host firmware", 1073 "Message": "The system has failed to shutdown the host firmware, look for other errors", 1074 "Notes": [ 1075 "This log indicates a critical BMC application required ", 1076 "to shutdown the host firmware has failed to start ", 1077 "successfully. Look in the log for other errors indicating ", 1078 "what has failed." 1079 ] 1080 } 1081 }, 1082 1083 { 1084 "Name": "xyz.openbmc_project.State.Host.Error.HostStopFailure", 1085 "Subsystem": "bmc_firmware", 1086 "ComponentID": "0x3400", 1087 "SRC": 1088 { 1089 "ReasonCode": "0x3412", 1090 "Words6To9": 1091 { 1092 } 1093 }, 1094 "Callouts": [ 1095 { 1096 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1097 } 1098 ], 1099 "Documentation": 1100 { 1101 "Description": "The system has failed to stop the host firmware", 1102 "Message": "The system has failed to stop the host firmware, look for other errors", 1103 "Notes": [ 1104 "This log indicates a critical BMC application required ", 1105 "to stop the host firmware has failed to start ", 1106 "successfully. Look in the log for other errors indicating ", 1107 "what has failed." 1108 ] 1109 } 1110 }, 1111 1112 { 1113 "Name": "xyz.openbmc_project.State.Host.Error.HostRebootFailure", 1114 "Subsystem": "bmc_firmware", 1115 "ComponentID": "0x3400", 1116 "SRC": 1117 { 1118 "ReasonCode": "0x3413", 1119 "Words6To9": 1120 { 1121 } 1122 }, 1123 "Callouts": [ 1124 { 1125 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1126 } 1127 ], 1128 "Documentation": 1129 { 1130 "Description": "The system has failed to reboot the host firmware", 1131 "Message": "The system has failed to reboot the host firmware, look for other errors", 1132 "Notes": [ 1133 "This log indicates a critical BMC application required ", 1134 "to reboot the host firmware has failed to start ", 1135 "successfully. Look in the log for other errors indicating ", 1136 "what has failed." 1137 ] 1138 } 1139 }, 1140 1141 { 1142 "Name": "xyz.openbmc_project.State.Error.HostQuiesce", 1143 "Subsystem": "bmc_firmware", 1144 "ComponentID": "0x3400", 1145 "SRC": 1146 { 1147 "ReasonCode": "0x3414", 1148 "Words6To9": 1149 { 1150 } 1151 }, 1152 "Callouts": [ 1153 { 1154 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1155 } 1156 ], 1157 "Documentation": 1158 { 1159 "Description": "The host firmware has failed to boot", 1160 "Message": "The host firmware has failed to boot and has entered a Quiesce state. Look for other errors.", 1161 "Notes": [ 1162 "This log indicates that the host firmware has failed to ", 1163 "boot and all retries have been exhausted. There should be ", 1164 "other logs with more details on the boot failure reason. " 1165 ] 1166 } 1167 }, 1168 1169 { 1170 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 1171 "Subsystem": "processor_chip", 1172 "ComponentID": "0x3500", 1173 1174 "SRC": 1175 { 1176 "ReasonCode": "0x3500", 1177 "Words6To9": 1178 { 1179 "6": 1180 { 1181 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1182 "AdditionalDataPropSource": "SRC6" 1183 } 1184 } 1185 }, 1186 1187 "Documentation": 1188 { 1189 "Description": "chipop failure with SBE provided FFDC", 1190 "Message": "chipop request failure reported by SBE", 1191 "Notes": [ 1192 "The severity is set by the creator.", 1193 "Callouts added based on SBE provided FFDC.", 1194 "SBE provided additional debug data included as part of the", 1195 "additional user data section." 1196 ] 1197 } 1198 }, 1199 1200 { 1201 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 1202 "Subsystem": "processor_chip", 1203 "ComponentID": "0x3500", 1204 1205 "SRC": 1206 { 1207 "ReasonCode": "0x3501", 1208 "Words6To9": 1209 { 1210 "6": 1211 { 1212 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1213 "AdditionalDataPropSource": "SRC6" 1214 } 1215 } 1216 }, 1217 1218 "Callouts": [ 1219 { 1220 "CalloutList": [ 1221 { "Priority": "high", "Procedure": "next_level_support" } 1222 ] 1223 } 1224 ], 1225 1226 "Documentation": 1227 { 1228 "Description": "SBE chipop timeout", 1229 "Message": "chipop timeout reported during SBE communication", 1230 "Notes": [ 1231 "The severity is set by the creator.", 1232 "Check SBE Dump associated to this error to debug the failure." 1233 ] 1234 } 1235 }, 1236 1237 { 1238 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 1239 "Subsystem": "processor_chip", 1240 "ComponentID": "0x3500", 1241 1242 "SRC": 1243 { 1244 "ReasonCode": "0x3502", 1245 "Words6To9": 1246 { 1247 "6": 1248 { 1249 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1250 "AdditionalDataPropSource": "SRC6" 1251 }, 1252 "7": 1253 { 1254 "Description": "Value of SBE state", 1255 "AdditionalDataPropSource": "SRC7" 1256 } 1257 } 1258 }, 1259 1260 "Documentation": 1261 { 1262 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 1263 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 1264 "Notes": [ 1265 "The severity is set by the creator." 1266 ] 1267 } 1268 }, 1269 1270 { 1271 "Name": "org.open_power.Processor.Error.SbeBootFailure", 1272 "Subsystem": "processor_chip", 1273 "ComponentID": "0x3500", 1274 1275 "SRC": 1276 { 1277 "ReasonCode": "0x3503", 1278 "Words6To9": 1279 { 1280 "6": 1281 { 1282 "Description": "[0:15] chip position", 1283 "AdditionalDataPropSource": "SRC6" 1284 } 1285 } 1286 }, 1287 1288 "Documentation": 1289 { 1290 "Description": "Boot failure with SBE provided FFDC", 1291 "Message": "Boot failure reported by SBE", 1292 "Notes": [ 1293 "The severity is set by the creator.", 1294 "Callouts added based on SBE provided FFDC.", 1295 "SBE provided additional debug data included as part of the", 1296 "additional user data section." 1297 ] 1298 } 1299 }, 1300 1301 { 1302 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 1303 "Subsystem": "processor_chip", 1304 "ComponentID": "0x3500", 1305 1306 "SRC": 1307 { 1308 "ReasonCode": "0x3504", 1309 "Words6To9": 1310 { 1311 } 1312 }, 1313 1314 "Callouts": [ 1315 { 1316 "System": "ibm,rainier", 1317 "CalloutList": [ 1318 { 1319 "Priority": "low", 1320 "LocCode": "P0" 1321 }, 1322 { 1323 "Priority": "low", 1324 "LocCode": "P0-C22" 1325 } 1326 ] 1327 }, 1328 { 1329 "System": "ibm,everest", 1330 "CalloutList": [ 1331 { 1332 "Priority": "low", 1333 "LocCode": "P0" 1334 }, 1335 { 1336 "Priority": "low", 1337 "LocCode": "P0-C96" 1338 } 1339 ] 1340 } 1341 ], 1342 1343 "Documentation": 1344 { 1345 "Description": "SBE Boot timeout", 1346 "Message": "timeout reported during SBE boot process", 1347 "Notes": [ 1348 "The severity is set by the creator.", 1349 "Check SBE Dump associated to this error to debug the failure." 1350 ] 1351 } 1352 }, 1353 1354 { 1355 "Name": "org.open_power.Attn.Error.Terminate", 1356 "Subsystem": "cec_hardware", 1357 "Severity": "non_error", 1358 1359 "SRC": 1360 { 1361 "ReasonCode": "0xD138", 1362 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 1363 "Words6To9": 1364 { 1365 } 1366 }, 1367 1368 "Documentation": 1369 { 1370 "Description": "Status shows TI special attention active", 1371 "Message": "TI special attention detected", 1372 "Notes": [ 1373 "This entry is for any TI special attention event ", 1374 "reported by the attention handler component" 1375 ] 1376 } 1377 }, 1378 1379 { 1380 "Name": "org.open_power.Attn.Error.Fail", 1381 "Subsystem": "bmc_firmware", 1382 "Severity": "unrecoverable_loss_of_function", 1383 1384 "SRC": 1385 { 1386 "ReasonCode": "0xD13E", 1387 "Words6To9": 1388 { 1389 "6": 1390 { 1391 "Description": "Error code from attention handler", 1392 "AdditionalDataPropSource": "ERROR_CODE" 1393 } 1394 } 1395 }, 1396 "Documentation": 1397 { 1398 "Description": "The attention handler encountered an error", 1399 "MessageArgSources" : ["SRCWord6"], 1400 "Message": "Attention handler error %1", 1401 "Notes": [ 1402 "Attention handler will provide error code" 1403 ] 1404 } 1405 }, 1406 1407 { 1408 "Name": "org.open_power.Attn.Error.Vital", 1409 "Subsystem": "processor_chip", 1410 "Severity": "critical", 1411 1412 "SRC": 1413 { 1414 "ReasonCode": "0xD16D", 1415 "Words6To9": 1416 { 1417 } 1418 }, 1419 1420 "Documentation": 1421 { 1422 "Description": "Status shows SBE vital attention active", 1423 "Message": "SBE vital attention detected", 1424 "Notes": [ 1425 "This entry is for any SBE vital attention event ", 1426 "reported by the attention handler component" 1427 ] 1428 } 1429 }, 1430 1431 { 1432 "Name": "org.open_power.HwDiags.Error.Checkstop", 1433 "PossibleSubsystems": [ 1434 "processor", "processor_fru", "processor_unit", "processor_bus", 1435 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1436 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1437 ], 1438 "Severity": "unrecoverable", 1439 "ActionFlags": [ "service_action", "report", "call_home" ], 1440 1441 "SRC": 1442 { 1443 "ReasonCode": "0xE510", 1444 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1445 "Words6To9": 1446 { 1447 "6": 1448 { 1449 "AdditionalDataPropSource": "SRC6" 1450 }, 1451 "7": 1452 { 1453 "AdditionalDataPropSource": "SRC7" 1454 }, 1455 "8": 1456 { 1457 "AdditionalDataPropSource": "SRC8" 1458 } 1459 } 1460 }, 1461 1462 "Documentation": 1463 { 1464 "Description": "A system checkstop attention has occurred", 1465 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1466 "Message": "Error Signature: %1 %2 %3" 1467 } 1468 }, 1469 1470 { 1471 "Name": "org.open_power.HwDiags.Error.Predictive", 1472 "PossibleSubsystems": [ 1473 "processor", "processor_fru", "processor_unit", "processor_bus", 1474 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1475 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1476 ], 1477 "Severity": "predictive", 1478 "ActionFlags": [ "service_action", "report", "call_home" ], 1479 1480 "SRC": 1481 { 1482 "ReasonCode": "0xE511", 1483 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1484 "Words6To9": 1485 { 1486 "6": 1487 { 1488 "AdditionalDataPropSource": "SRC6" 1489 }, 1490 "7": 1491 { 1492 "AdditionalDataPropSource": "SRC7" 1493 }, 1494 "8": 1495 { 1496 "AdditionalDataPropSource": "SRC8" 1497 } 1498 } 1499 }, 1500 1501 "Documentation": 1502 { 1503 "Description": "A hardware attention requiring service has occurred", 1504 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1505 "Message": "Error Signature: %1 %2 %3" 1506 } 1507 }, 1508 1509 { 1510 "Name": "org.open_power.HwDiags.Error.Informational", 1511 "PossibleSubsystems": [ 1512 "processor", "processor_fru", "processor_unit", "processor_bus", 1513 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1514 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1515 ], 1516 "Severity": "non_error", 1517 "ActionFlags": [ "hidden", "dont_report" ], 1518 1519 "SRC": 1520 { 1521 "ReasonCode": "0xE512", 1522 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1523 "Words6To9": 1524 { 1525 "6": 1526 { 1527 "AdditionalDataPropSource": "SRC6" 1528 }, 1529 "7": 1530 { 1531 "AdditionalDataPropSource": "SRC7" 1532 }, 1533 "8": 1534 { 1535 "AdditionalDataPropSource": "SRC8" 1536 } 1537 } 1538 }, 1539 1540 "Documentation": 1541 { 1542 "Description": "Manual analysis was initiated via the command line. FFDC only.", 1543 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1544 "Message": "Error Signature: %1 %2 %3" 1545 } 1546 }, 1547 1548 { 1549 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 1550 "Subsystem": "power_supply", 1551 "ActionFlags": ["service_action", "report"], 1552 "ComponentID": "0x2700", 1553 1554 "SRC": { 1555 "Type": "11", 1556 "ReasonCode": "0x15F0", 1557 "Words6To9": {} 1558 }, 1559 1560 "Callouts": [ 1561 { 1562 "CalloutList": [ 1563 { "Priority": "high", "SymbolicFRU": "pwrsply" } 1564 ] 1565 } 1566 ], 1567 1568 "Documentation": { 1569 "Description": "Power Supply input power fault", 1570 "Message": "A power supply has indicated an input or under voltage condition.", 1571 "Notes": [ 1572 "Check the power supply cabling and/or input power ", 1573 "source. The PWRSPLY procedure is used rather than ", 1574 "calling out a location code, as typically these faults ", 1575 "are related to the supplied power, the cable, or the ", 1576 "cable connectors. If the input fault resolves down to an ", 1577 "issue with the power supply itself, the power supply ", 1578 "indicating this input fault should be called out. Add the ", 1579 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 1580 "CALLOUT_PRIORITY to something other than high." 1581 ] 1582 } 1583 }, 1584 1585 { 1586 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 1587 "Subsystem": "power_supply", 1588 "ActionFlags": ["service_action", "report", "call_home"], 1589 "ComponentID": "0x2700", 1590 1591 "SRC": { 1592 "Type": "11", 1593 "ReasonCode": "0x15F1", 1594 "Words6To9": {} 1595 }, 1596 1597 "Callouts": [ 1598 { 1599 "CalloutList": [ 1600 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1601 ] 1602 } 1603 ], 1604 1605 "Documentation": { 1606 "Description": "Power Supply power fault", 1607 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 1608 "Notes": [ 1609 "The power supply reporting the fault should be called ", 1610 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1611 "specific fault, STATUS_* details, and code level in the ", 1612 "AdditionalData section." 1613 ] 1614 } 1615 }, 1616 1617 { 1618 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 1619 "Subsystem": "power_supply", 1620 "ActionFlags": ["service_action", "report", "call_home"], 1621 "ComponentID": "0x2700", 1622 1623 "SRC": { 1624 "Type": "11", 1625 "ReasonCode": "0x15F2", 1626 "Words6To9": {} 1627 }, 1628 1629 "Callouts": [ 1630 { 1631 "CalloutList": [ 1632 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1633 ] 1634 } 1635 ], 1636 1637 "Documentation": { 1638 "Description": "Power Supply non-power fault", 1639 "Message": "A communication failure occurred talking to the power supply", 1640 "Notes": [ 1641 "Communication problems with the power supply could be ", 1642 "the power supply, or any hardware between it and the ", 1643 "BMC. Reporting the error should be passing in a call ", 1644 "out using CALLOUT_DEVICE_PATH." 1645 ] 1646 } 1647 }, 1648 1649 { 1650 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 1651 "Subsystem": "power_supply", 1652 "ActionFlags": ["service_action", "report", "call_home"], 1653 "ComponentID": "0x2700", 1654 1655 "SRC": { 1656 "Type": "11", 1657 "ReasonCode": "0x15F6", 1658 "Words6To9": {} 1659 }, 1660 1661 "Callouts": [ 1662 { 1663 "CalloutList": [ 1664 { 1665 "Priority": "high", 1666 "SymbolicFRUTrusted": "pwrsply", 1667 "UseInventoryLocCode": true 1668 } 1669 ] 1670 } 1671 ], 1672 1673 "Documentation": { 1674 "Description": "Power Supply is missing", 1675 "Message": "A power supply that should be present is missing", 1676 "Notes": [ 1677 "The CalloutList should use the PWRSPLY symbolic FRU ", 1678 "with the trusted location code property. The ", 1679 "location code in this callout is obtained from ", 1680 "the passed in CALLOUT_INVENTORY_PATH value." 1681 ] 1682 } 1683 }, 1684 1685 { 1686 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 1687 "Subsystem": "power_supply", 1688 "ActionFlags": ["service_action", "report", "call_home"], 1689 "ComponentID": "0x2700", 1690 1691 "SRC": { 1692 "Type": "11", 1693 "ReasonCode": "0x15F7", 1694 "Words6To9": {} 1695 }, 1696 1697 "Callouts": [ 1698 { 1699 "CalloutList": [ 1700 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1701 ] 1702 } 1703 ], 1704 1705 "Documentation": { 1706 "Description": "Power Supply configuration is not supported", 1707 "Message": "The power supply configuration is not supported", 1708 "Notes": [ 1709 "The combination of power supplies detected in the ", 1710 "system is not supported. This could be caused by ", 1711 "mismatched models, less than expected number of power ", 1712 "supplies, or other unsupported characteristics." 1713 ] 1714 } 1715 }, 1716 1717 { 1718 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.FanFault", 1719 "Subsystem": "power_supply", 1720 "ActionFlags": ["service_action", "report", "call_home"], 1721 "ComponentID": "0x2700", 1722 1723 "SRC": { 1724 "Type": "11", 1725 "ReasonCode": "0x15FF", 1726 "Words6To9": {} 1727 }, 1728 1729 "Callouts": [ 1730 { 1731 "CalloutList": [ 1732 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1733 ] 1734 } 1735 ], 1736 1737 "Documentation": { 1738 "Description": "Power Supply fan fault", 1739 "Message": "A power supply indicated a fan fault has occurred", 1740 "Notes": [ 1741 "The power supply reporting the fault should be called ", 1742 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1743 "specific fault, STATUS_* details, and code level in the ", 1744 "AdditionalData section." 1745 ] 1746 } 1747 }, 1748 1749 { 1750 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 1751 "Subsystem": "power_supply", 1752 "ActionFlags": ["service_action", "report", "call_home"], 1753 "ComponentID": "0x2700", 1754 1755 "SRC": { 1756 "Type": "11", 1757 "ReasonCode": "0x1B01", 1758 "Words6To9": {} 1759 }, 1760 1761 "Callouts": [ 1762 { 1763 "CalloutList": [ 1764 { "Priority": "high", "Procedure": "power_overcurrent" } 1765 ] 1766 } 1767 ], 1768 1769 "Documentation": { 1770 "Description": "Power Supply output over-current power fault", 1771 "Message": "A power supply has indicated an output over-current condition." 1772 } 1773 }, 1774 1775 { 1776 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1777 "Subsystem": "power", 1778 "ActionFlags": [ "report", "service_action" ], 1779 "ComponentID": "0x2700", 1780 1781 "SRC": 1782 { 1783 "Type": "11", 1784 "ReasonCode": "0x00AC", 1785 "Words6To9": {} 1786 }, 1787 1788 "Callouts": [ 1789 { 1790 "CalloutList": [ 1791 { "Priority": "high", "SymbolicFRU": "ac_module"} 1792 ] 1793 } 1794 ], 1795 1796 "Documentation": { 1797 "Description": "Input power was lost while the system was powered on.", 1798 "Message": "Input power was lost while the system was powered on.", 1799 "Notes": [ 1800 "Input power was lost while system powered on.", 1801 "The CalloutList should use the ACMODUL symbolic FRU." 1802 ] 1803 } 1804 }, 1805 1806 { 1807 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1808 "Subsystem": "power_supply", 1809 "ActionFlags": ["service_action", "report", "call_home"], 1810 "ComponentID": "0x2700", 1811 1812 "SRC": { 1813 "Type": "11", 1814 "ReasonCode": "0x2500", 1815 "Words6To9": {} 1816 }, 1817 1818 "Callouts": [ 1819 { 1820 "CalloutList": [ 1821 { "Priority": "high", "Procedure": "power_overcurrent" } 1822 ] 1823 } 1824 ], 1825 1826 "Documentation": { 1827 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1828 "Message": "Power supply PSKill_fault", 1829 "Notes": [ 1830 ] 1831 } 1832 }, 1833 1834 { 1835 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1836 "Subsystem": "power_sequencer", 1837 "ComponentID": "0x2700", 1838 1839 "SRC": { 1840 "Type": "11", 1841 "ReasonCode": "0x2600", 1842 "Words6To9": {} 1843 }, 1844 1845 "Callouts": [ 1846 { 1847 "CalloutList": [ 1848 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1849 ] 1850 } 1851 ], 1852 1853 "Documentation": { 1854 "Description": "A power off was issued because a power fault was detected", 1855 "Message": "A power off was issued because a power fault was detected", 1856 "Notes": [ 1857 ] 1858 } 1859 }, 1860 1861 { 1862 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1863 "Subsystem": "power_control_hw", 1864 "Severity": "critical_system_term", 1865 "ComponentID": "0x2700", 1866 1867 "SRC": { 1868 "Type": "11", 1869 "ReasonCode": "0x2602", 1870 "Words6To9": {} 1871 }, 1872 1873 "Callouts": [ 1874 { 1875 "System": "ibm,rainier", 1876 "CalloutList": [ 1877 { 1878 "Priority": "high", 1879 "LocCode": "P0-C5" 1880 }, 1881 { 1882 "Priority": "medium", 1883 "LocCode": "P0" 1884 } 1885 ] 1886 }, 1887 { 1888 "System": "ibm,everest", 1889 "CalloutList": [ 1890 { 1891 "Priority": "high", 1892 "LocCode": "P0-C59" 1893 }, 1894 { 1895 "Priority": "medium", 1896 "LocCode": "P0" 1897 } 1898 ] 1899 } 1900 ], 1901 1902 "Documentation": { 1903 "Description": "A power off was issued because a regulator for standby power faulted", 1904 "Message": "A power off was issued because a regulator for standby power faulted", 1905 "Notes": [ 1906 ] 1907 } 1908 }, 1909 1910 { 1911 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1912 "Subsystem": "power_sequencer", 1913 "ComponentID": "0x2700", 1914 1915 "SRC": { 1916 "Type": "11", 1917 "ReasonCode": "0x2610", 1918 "Words6To9": {} 1919 }, 1920 1921 "CalloutsUsingAD": { 1922 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1923 { 1924 "ADValue": "PCIE_SLOT0", "Callouts": [ 1925 { 1926 "CalloutList": [ 1927 { "Priority": "high", "LocCode": "P0-C0" }, 1928 { "Priority": "medium", "LocCode": "P0" } 1929 ] 1930 } 1931 ] 1932 }, 1933 { 1934 "ADValue": "PCIE_SLOT1", "Callouts": [ 1935 { 1936 "CalloutList": [ 1937 { "Priority": "high", "LocCode": "P0-C1" }, 1938 { "Priority": "medium", "LocCode": "P0" } 1939 ] 1940 } 1941 ] 1942 }, 1943 { 1944 "ADValue": "PCIE_SLOT2", "Callouts": [ 1945 { 1946 "CalloutList": [ 1947 { "Priority": "high", "LocCode": "P0-C2" }, 1948 { "Priority": "medium", "LocCode": "P0" } 1949 ] 1950 } 1951 ] 1952 }, 1953 { 1954 "ADValue": "PCIE_SLOT3", "Callouts": [ 1955 { 1956 "CalloutList": [ 1957 { "Priority": "high", "LocCode": "P0-C3" }, 1958 { "Priority": "medium", "LocCode": "P0" } 1959 ] 1960 } 1961 ] 1962 }, 1963 { 1964 "ADValue": "PCIE_SLOT4", "Callouts": [ 1965 { 1966 "CalloutList": [ 1967 { "Priority": "high", "LocCode": "P0-C4" }, 1968 { "Priority": "medium", "LocCode": "P0" } 1969 ] 1970 } 1971 ] 1972 }, 1973 { 1974 "ADValue": "PCIE_SLOT5", "Callouts": [ 1975 { 1976 "CalloutList": [ 1977 { "Priority": "high", "LocCode": "P0-C5" }, 1978 { "Priority": "medium", "LocCode": "P0" } 1979 ] 1980 } 1981 ] 1982 }, 1983 { 1984 "ADValue": "PCIE_SLOT6", "Callouts": [ 1985 { 1986 "CalloutList": [ 1987 { "Priority": "high", "LocCode": "P0-C6" }, 1988 { "Priority": "medium", "LocCode": "P0" } 1989 ] 1990 } 1991 ] 1992 }, 1993 { 1994 "ADValue": "PCIE_SLOT7", "Callouts": [ 1995 { 1996 "CalloutList": [ 1997 { "Priority": "high", "LocCode": "P0-C7" }, 1998 { "Priority": "medium", "LocCode": "P0" } 1999 ] 2000 } 2001 ] 2002 }, 2003 { 2004 "ADValue": "PCIE_SLOT8", "Callouts": [ 2005 { 2006 "CalloutList": [ 2007 { "Priority": "high", "LocCode": "P0-C8" }, 2008 { "Priority": "medium", "LocCode": "P0" } 2009 ] 2010 } 2011 ] 2012 }, 2013 { 2014 "ADValue": "PCIE_SLOT9", "Callouts": [ 2015 { 2016 "CalloutList": [ 2017 { "Priority": "high", "LocCode": "P0-C9" }, 2018 { "Priority": "medium", "LocCode": "P0" } 2019 ] 2020 } 2021 ] 2022 }, 2023 { 2024 "ADValue": "PCIE_SLOT10", "Callouts": [ 2025 { 2026 "CalloutList": [ 2027 { "Priority": "high", "LocCode": "P0-C10" }, 2028 { "Priority": "medium", "LocCode": "P0" } 2029 ] 2030 } 2031 ] 2032 }, 2033 { 2034 "ADValue": "PCIE_SLOT11", "Callouts": [ 2035 { 2036 "CalloutList": [ 2037 { "Priority": "high", "LocCode": "P0-C11" }, 2038 { "Priority": "medium", "LocCode": "P0" } 2039 ] 2040 } 2041 ] 2042 }, 2043 { 2044 "ADValue": "PGOOD_12A", "Callouts": [ 2045 { 2046 "CalloutList": [ 2047 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2048 ] 2049 } 2050 ] 2051 }, 2052 { 2053 "ADValue": "PGOOD_12B", "Callouts": [ 2054 { 2055 "CalloutList": [ 2056 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2057 ] 2058 } 2059 ] 2060 }, 2061 { 2062 "ADValue": "PGOOD_12C", "Callouts": [ 2063 { 2064 "CalloutList": [ 2065 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2066 ] 2067 } 2068 ] 2069 }, 2070 { 2071 "ADValue": "PGOOD_12D", "Callouts": [ 2072 { 2073 "CalloutList": [ 2074 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2075 ] 2076 } 2077 ] 2078 }, 2079 { 2080 "ADValue": "PGOOD_12L", "Callouts": [ 2081 { 2082 "CalloutList": [ 2083 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2084 ] 2085 } 2086 ] 2087 }, 2088 { 2089 "ADValue": "PGOOD_12M", "Callouts": [ 2090 { 2091 "CalloutList": [ 2092 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2093 ] 2094 } 2095 ] 2096 }, 2097 { 2098 "ADValue": "PGOOD_12N", "Callouts": [ 2099 { 2100 "CalloutList": [ 2101 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2102 ] 2103 } 2104 ] 2105 }, 2106 { 2107 "ADValue": "PGOOD_12P", "Callouts": [ 2108 { 2109 "CalloutList": [ 2110 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2111 ] 2112 } 2113 ] 2114 }, 2115 { 2116 "ADValue": "PGOOD_12PCIE", "Callouts": [ 2117 { 2118 "CalloutList": [ 2119 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2120 ] 2121 } 2122 ] 2123 }, 2124 { 2125 "ADValue": "PGOOD_12Q", "Callouts": [ 2126 { 2127 "CalloutList": [ 2128 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2129 ] 2130 } 2131 ] 2132 }, 2133 { 2134 "ADValue": "PGOOD_12R", "Callouts": [ 2135 { 2136 "CalloutList": [ 2137 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2138 ] 2139 } 2140 ] 2141 }, 2142 { 2143 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 2144 { 2145 "CalloutList": [ 2146 { "Priority": "high", "LocCode": "P0-C14" }, 2147 { "Priority": "medium", "LocCode": "P0-C15" }, 2148 { "Priority": "low", "LocCode": "P0" } 2149 ] 2150 } 2151 ] 2152 }, 2153 { 2154 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 2155 { 2156 "CalloutList": [ 2157 { "Priority": "high", "LocCode": "P0-C23" }, 2158 { "Priority": "medium", "LocCode": "P0-C24" }, 2159 { "Priority": "low", "LocCode": "P0" } 2160 ] 2161 } 2162 ] 2163 }, 2164 { 2165 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 2166 { 2167 "CalloutList": [ 2168 { "Priority": "high", "LocCode": "P0-C14" }, 2169 { "Priority": "medium", "LocCode": "P0-C15" }, 2170 { "Priority": "low", "LocCode": "P0" } 2171 ] 2172 } 2173 ] 2174 }, 2175 { 2176 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 2177 { 2178 "CalloutList": [ 2179 { "Priority": "high", "LocCode": "P0-C23" }, 2180 { "Priority": "medium", "LocCode": "P0-C24" }, 2181 { "Priority": "low", "LocCode": "P0" } 2182 ] 2183 } 2184 ] 2185 }, 2186 { 2187 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 2188 { 2189 "CalloutList": [ 2190 { "Priority": "high", "LocCode": "P0-C14" }, 2191 { "Priority": "medium", "LocCode": "P0-C15" }, 2192 { "Priority": "low", "LocCode": "P0" } 2193 ] 2194 } 2195 ] 2196 }, 2197 { 2198 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 2199 { 2200 "CalloutList": [ 2201 { "Priority": "high", "LocCode": "P0-C23" }, 2202 { "Priority": "medium", "LocCode": "P0-C24" }, 2203 { "Priority": "low", "LocCode": "P0" } 2204 ] 2205 } 2206 ] 2207 }, 2208 { 2209 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 2210 { 2211 "CalloutList": [ 2212 { "Priority": "high", "LocCode": "P0-C14" }, 2213 { "Priority": "medium", "LocCode": "P0-C15" }, 2214 { "Priority": "low", "LocCode": "P0" } 2215 ] 2216 } 2217 ] 2218 }, 2219 { 2220 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 2221 { 2222 "CalloutList": [ 2223 { "Priority": "high", "LocCode": "P0-C23" }, 2224 { "Priority": "medium", "LocCode": "P0-C24" }, 2225 { "Priority": "low", "LocCode": "P0" } 2226 ] 2227 } 2228 ] 2229 }, 2230 { 2231 "ADValue": "CP0_VPCIE", "Callouts": [ 2232 { 2233 "CalloutList": [ 2234 { "Priority": "high", "LocCode": "P0-C58" }, 2235 { "Priority": "medium", "LocCode": "P0-C61" }, 2236 { "Priority": "low", "LocCode": "P0" } 2237 ] 2238 } 2239 ] 2240 }, 2241 { 2242 "ADValue": "CP1_VPCIE", "Callouts": [ 2243 { 2244 "CalloutList": [ 2245 { "Priority": "high", "LocCode": "P0-C16" }, 2246 { "Priority": "medium", "LocCode": "P0-C14" }, 2247 { "Priority": "low", "LocCode": "P0" } 2248 ] 2249 } 2250 ] 2251 }, 2252 { 2253 "ADValue": "CP2_VPCIE", "Callouts": [ 2254 { 2255 "CalloutList": [ 2256 { "Priority": "high", "LocCode": "P0-C16" }, 2257 { "Priority": "medium", "LocCode": "P0-C19" }, 2258 { "Priority": "low", "LocCode": "P0" } 2259 ] 2260 } 2261 ] 2262 }, 2263 { 2264 "ADValue": "CP3_VPCIE", "Callouts": [ 2265 { 2266 "CalloutList": [ 2267 { "Priority": "high", "LocCode": "P0-C58" }, 2268 { "Priority": "medium", "LocCode": "P0-C56" }, 2269 { "Priority": "low", "LocCode": "P0" } 2270 ] 2271 } 2272 ] 2273 }, 2274 { 2275 "ADValue": "5.0V_USB_front", "Callouts": [ 2276 { 2277 "CalloutList": [ 2278 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2279 { "Priority": "low", "LocCode": "P1" }, 2280 { "Priority": "low", "LocCode": "P0" } 2281 ] 2282 } 2283 ] 2284 }, 2285 { 2286 "ADValue": "CP0_VDN", "Callouts": [ 2287 { 2288 "CalloutList": [ 2289 { "Priority": "high", "LocCode": "P0-C63" }, 2290 { "Priority": "medium", "LocCode": "P0-C61" }, 2291 { "Priority": "low", "LocCode": "P0" } 2292 ] 2293 } 2294 ] 2295 }, 2296 { 2297 "ADValue": "CP1_VDN", "Callouts": [ 2298 { 2299 "CalloutList": [ 2300 { "Priority": "high", "LocCode": "P0-C12" }, 2301 { "Priority": "medium", "LocCode": "P0-C14" }, 2302 { "Priority": "low", "LocCode": "P0" } 2303 ] 2304 } 2305 ] 2306 }, 2307 { 2308 "ADValue": "CP2_VDN", "Callouts": [ 2309 { 2310 "CalloutList": [ 2311 { "Priority": "high", "LocCode": "P0-C21" }, 2312 { "Priority": "medium", "LocCode": "P0-C19" }, 2313 { "Priority": "low", "LocCode": "P0" } 2314 ] 2315 } 2316 ] 2317 }, 2318 { 2319 "ADValue": "CP3_VDN", "Callouts": [ 2320 { 2321 "CalloutList": [ 2322 { "Priority": "high", "LocCode": "P0-C54" }, 2323 { "Priority": "medium", "LocCode": "P0-C56" }, 2324 { "Priority": "low", "LocCode": "P0" } 2325 ] 2326 } 2327 ] 2328 }, 2329 { 2330 "ADValue": "CP0_VIO", "Callouts": [ 2331 { 2332 "CalloutList": [ 2333 { "Priority": "high", "LocCode": "P0-C63" }, 2334 { "Priority": "medium", "LocCode": "P0-C61" }, 2335 { "Priority": "low", "LocCode": "P0" } 2336 ] 2337 } 2338 ] 2339 }, 2340 { 2341 "ADValue": "CP1_VIO", "Callouts": [ 2342 { 2343 "CalloutList": [ 2344 { "Priority": "high", "LocCode": "P0-C12" }, 2345 { "Priority": "medium", "LocCode": "P0-C14" }, 2346 { "Priority": "low", "LocCode": "P0" } 2347 ] 2348 } 2349 ] 2350 }, 2351 { 2352 "ADValue": "CP2_VIO", "Callouts": [ 2353 { 2354 "CalloutList": [ 2355 { "Priority": "high", "LocCode": "P0-C21" }, 2356 { "Priority": "medium", "LocCode": "P0-C19" }, 2357 { "Priority": "low", "LocCode": "P0" } 2358 ] 2359 } 2360 ] 2361 }, 2362 { 2363 "ADValue": "CP3_VIO", "Callouts": [ 2364 { 2365 "CalloutList": [ 2366 { "Priority": "high", "LocCode": "P0-C54" }, 2367 { "Priority": "medium", "LocCode": "P0-C56" }, 2368 { "Priority": "low", "LocCode": "P0" } 2369 ] 2370 } 2371 ] 2372 }, 2373 { 2374 "ADValue": "PGOOD_PSU1", "Callouts": [ 2375 { 2376 "CalloutList": [ 2377 { "Priority": "high", "LocCode": "E0" } 2378 ] 2379 } 2380 ] 2381 }, 2382 { 2383 "ADValue": "PGOOD_PSU2", "Callouts": [ 2384 { 2385 "CalloutList": [ 2386 { "Priority": "high", "LocCode": "E1" } 2387 ] 2388 } 2389 ] 2390 }, 2391 { 2392 "ADValue": "PGOOD_PSU3", "Callouts": [ 2393 { 2394 "CalloutList": [ 2395 { "Priority": "high", "LocCode": "E2" } 2396 ] 2397 } 2398 ] 2399 }, 2400 { 2401 "ADValue": "PGOOD_PSU4", "Callouts": [ 2402 { 2403 "CalloutList": [ 2404 { "Priority": "high", "LocCode": "E3" } 2405 ] 2406 } 2407 ] 2408 } 2409 ] 2410 }, 2411 2412 "Documentation": { 2413 "Description": "The power sequencer chip detected a PGOOD fault", 2414 "Message": "The power sequencer chip detected a PGOOD fault", 2415 "Notes": [ 2416 ] 2417 } 2418 }, 2419 2420 { 2421 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 2422 "Subsystem": "power_sequencer", 2423 "ComponentID": "0x2700", 2424 2425 "SRC": { 2426 "Type": "11", 2427 "ReasonCode": "0x2620", 2428 "Words6To9": {} 2429 }, 2430 2431 "CalloutsUsingAD": { 2432 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 2433 { 2434 "ADValue": "12.0V", "Callouts": [ 2435 { 2436 "CalloutList": [ 2437 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2438 ] 2439 } 2440 ] 2441 }, 2442 { 2443 "ADValue": "5.0V_USB", "Callouts": [ 2444 { 2445 "CalloutList": [ 2446 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2447 { "Priority": "medium", "LocCode": "P0" } 2448 ] 2449 } 2450 ] 2451 }, 2452 { 2453 "ADValue": "5.0V_DASD", "Callouts": [ 2454 { 2455 "CalloutList": [ 2456 { "Priority": "medium", "LocCode": "P1" }, 2457 { "Priority": "medium", "LocCode": "P2" }, 2458 { "Priority": "low", "LocCode": "P0" } 2459 ] 2460 } 2461 ] 2462 }, 2463 { 2464 "ADValue": "3.3VA", "Callouts": [ 2465 { 2466 "CalloutList": [ 2467 { "Priority": "high", "LocCode": "P0" } 2468 ] 2469 } 2470 ] 2471 }, 2472 { 2473 "ADValue": "3.3VB", "Callouts": [ 2474 { 2475 "CalloutList": [ 2476 { "Priority": "high", "LocCode": "P0" } 2477 ] 2478 } 2479 ] 2480 }, 2481 { 2482 "ADValue": "3V3IO", "Callouts": [ 2483 { 2484 "CalloutList": [ 2485 { "Priority": "high", "LocCode": "P0-C17" }, 2486 { "Priority": "medium", "LocCode": "P0-C96" }, 2487 { "Priority": "medium", "LocCode": "P0-C0" }, 2488 { "Priority": "medium", "SymbolicFRU": "pcie_hot_plug" }, 2489 { "Priority": "low", "LocCode": "P0" } 2490 ] 2491 } 2492 ] 2493 }, 2494 { 2495 "ADValue": "1.5V", "Callouts": [ 2496 { 2497 "CalloutList": [ 2498 { "Priority": "high", "LocCode": "P0" } 2499 ] 2500 } 2501 ] 2502 }, 2503 { 2504 "ADValue": "1.1V", "Callouts": [ 2505 { 2506 "CalloutList": [ 2507 { "Priority": "high", "LocCode": "P0" } 2508 ] 2509 } 2510 ] 2511 }, 2512 { 2513 "ADValue": "VDDA_DCM0", "Callouts": [ 2514 { 2515 "CalloutList": [ 2516 { "Priority": "high", "LocCode": "P0-C14" }, 2517 { "Priority": "medium", "LocCode": "P0-C15" }, 2518 { "Priority": "low", "LocCode": "P0" } 2519 ] 2520 } 2521 ] 2522 }, 2523 { 2524 "ADValue": "VDDB_DCM0", "Callouts": [ 2525 { 2526 "CalloutList": [ 2527 { "Priority": "high", "LocCode": "P0-C14" }, 2528 { "Priority": "medium", "LocCode": "P0-C15" }, 2529 { "Priority": "low", "LocCode": "P0" } 2530 ] 2531 } 2532 ] 2533 }, 2534 { 2535 "ADValue": "VDDA_DCM1", "Callouts": [ 2536 { 2537 "CalloutList": [ 2538 { "Priority": "high", "LocCode": "P0-C23" }, 2539 { "Priority": "medium", "LocCode": "P0-C24" }, 2540 { "Priority": "low", "LocCode": "P0" } 2541 ] 2542 } 2543 ] 2544 }, 2545 { 2546 "ADValue": "VDDB_DCM1", "Callouts": [ 2547 { 2548 "CalloutList": [ 2549 { "Priority": "high", "LocCode": "P0-C23" }, 2550 { "Priority": "medium", "LocCode": "P0-C24" }, 2551 { "Priority": "low", "LocCode": "P0" } 2552 ] 2553 } 2554 ] 2555 }, 2556 { 2557 "ADValue": "CP03_AVDD", "Callouts": [ 2558 { 2559 "CalloutList": [ 2560 { "Priority": "high", "LocCode": "P0-C58" }, 2561 { "Priority": "medium", "LocCode": "P0-C61" }, 2562 { "Priority": "medium", "LocCode": "P0-C56" }, 2563 { "Priority": "low", "LocCode": "P0" } 2564 ] 2565 } 2566 ] 2567 }, 2568 { 2569 "ADValue": "CP12_AVDD", "Callouts": [ 2570 { 2571 "CalloutList": [ 2572 { "Priority": "high", "LocCode": "P0-C16" }, 2573 { "Priority": "medium", "LocCode": "P0-C14" }, 2574 { "Priority": "medium", "LocCode": "P0-C19" }, 2575 { "Priority": "low", "LocCode": "P0" } 2576 ] 2577 } 2578 ] 2579 }, 2580 { 2581 "ADValue": "CP0_VDD0", "Callouts": [ 2582 { 2583 "CalloutList": [ 2584 { "Priority": "high", "LocCode": "P0-C62" }, 2585 { "Priority": "medium", "LocCode": "P0-C61" }, 2586 { "Priority": "low", "LocCode": "P0" } 2587 ] 2588 } 2589 ] 2590 }, 2591 { 2592 "ADValue": "CP0_VDD1", "Callouts": [ 2593 { 2594 "CalloutList": [ 2595 { "Priority": "high", "LocCode": "P0-C60" }, 2596 { "Priority": "medium", "LocCode": "P0-C61" }, 2597 { "Priority": "low", "LocCode": "P0" } 2598 ] 2599 } 2600 ] 2601 }, 2602 { 2603 "ADValue": "CP1_VDD0", "Callouts": [ 2604 { 2605 "CalloutList": [ 2606 { "Priority": "high", "LocCode": "P0-C13" }, 2607 { "Priority": "medium", "LocCode": "P0-C14" }, 2608 { "Priority": "low", "LocCode": "P0" } 2609 ] 2610 } 2611 ] 2612 }, 2613 { 2614 "ADValue": "CP1_VDD1", "Callouts": [ 2615 { 2616 "CalloutList": [ 2617 { "Priority": "high", "LocCode": "P0-C15" }, 2618 { "Priority": "medium", "LocCode": "P0-C14" }, 2619 { "Priority": "low", "LocCode": "P0" } 2620 ] 2621 } 2622 ] 2623 }, 2624 { 2625 "ADValue": "CP2_VDD0", "Callouts": [ 2626 { 2627 "CalloutList": [ 2628 { "Priority": "high", "LocCode": "P0-C18" }, 2629 { "Priority": "medium", "LocCode": "P0-C19" }, 2630 { "Priority": "low", "LocCode": "P0" } 2631 ] 2632 } 2633 ] 2634 }, 2635 { 2636 "ADValue": "CP2_VDD1", "Callouts": [ 2637 { 2638 "CalloutList": [ 2639 { "Priority": "high", "LocCode": "P0-C20" }, 2640 { "Priority": "medium", "LocCode": "P0-C19" }, 2641 { "Priority": "low", "LocCode": "P0" } 2642 ] 2643 } 2644 ] 2645 }, 2646 { 2647 "ADValue": "CP3_VDD0", "Callouts": [ 2648 { 2649 "CalloutList": [ 2650 { "Priority": "high", "LocCode": "P0-C57" }, 2651 { "Priority": "medium", "LocCode": "P0-C56" }, 2652 { "Priority": "low", "LocCode": "P0" } 2653 ] 2654 } 2655 ] 2656 }, 2657 { 2658 "ADValue": "CP3_VDD1", "Callouts": [ 2659 { 2660 "CalloutList": [ 2661 { "Priority": "high", "LocCode": "P0-C55" }, 2662 { "Priority": "medium", "LocCode": "P0-C56" }, 2663 { "Priority": "low", "LocCode": "P0" } 2664 ] 2665 } 2666 ] 2667 }, 2668 { 2669 "ADValue": "CP0_VCS0", "Callouts": [ 2670 { 2671 "CalloutList": [ 2672 { "Priority": "high", "LocCode": "P0-C63" }, 2673 { "Priority": "medium", "LocCode": "P0-C61" }, 2674 { "Priority": "low", "LocCode": "P0" } 2675 ] 2676 } 2677 ] 2678 }, 2679 { 2680 "ADValue": "CP0_VCS1", "Callouts": [ 2681 { 2682 "CalloutList": [ 2683 { "Priority": "high", "LocCode": "P0-C59" }, 2684 { "Priority": "medium", "LocCode": "P0-C61" }, 2685 { "Priority": "low", "LocCode": "P0" } 2686 ] 2687 } 2688 ] 2689 }, 2690 { 2691 "ADValue": "CP1_VCS0", "Callouts": [ 2692 { 2693 "CalloutList": [ 2694 { "Priority": "high", "LocCode": "P0-C12" }, 2695 { "Priority": "medium", "LocCode": "P0-C14" }, 2696 { "Priority": "low", "LocCode": "P0" } 2697 ] 2698 } 2699 ] 2700 }, 2701 { 2702 "ADValue": "CP1_VCS1", "Callouts": [ 2703 { 2704 "CalloutList": [ 2705 { "Priority": "high", "LocCode": "P0-C16" }, 2706 { "Priority": "medium", "LocCode": "P0-C14" }, 2707 { "Priority": "low", "LocCode": "P0" } 2708 ] 2709 } 2710 ] 2711 }, 2712 { 2713 "ADValue": "CP2_VCS0", "Callouts": [ 2714 { 2715 "CalloutList": [ 2716 { "Priority": "high", "LocCode": "P0-C17" }, 2717 { "Priority": "medium", "LocCode": "P0-C19" }, 2718 { "Priority": "low", "LocCode": "P0" } 2719 ] 2720 } 2721 ] 2722 }, 2723 { 2724 "ADValue": "CP2_VCS1", "Callouts": [ 2725 { 2726 "CalloutList": [ 2727 { "Priority": "high", "LocCode": "P0-C21" }, 2728 { "Priority": "medium", "LocCode": "P0-C19" }, 2729 { "Priority": "low", "LocCode": "P0" } 2730 ] 2731 } 2732 ] 2733 }, 2734 { 2735 "ADValue": "CP3_VCS0", "Callouts": [ 2736 { 2737 "CalloutList": [ 2738 { "Priority": "high", "LocCode": "P0-C58" }, 2739 { "Priority": "medium", "LocCode": "P0-C56" }, 2740 { "Priority": "low", "LocCode": "P0" } 2741 ] 2742 } 2743 ] 2744 }, 2745 { 2746 "ADValue": "CP3_VCS1", "Callouts": [ 2747 { 2748 "CalloutList": [ 2749 { "Priority": "high", "LocCode": "P0-C54" }, 2750 { "Priority": "medium", "LocCode": "P0-C56" }, 2751 { "Priority": "low", "LocCode": "P0" } 2752 ] 2753 } 2754 ] 2755 }, 2756 { 2757 "ADValue": "CP0_VDN", "Callouts": [ 2758 { 2759 "CalloutList": [ 2760 { "Priority": "high", "LocCode": "P0-C63" }, 2761 { "Priority": "medium", "LocCode": "P0-C61" }, 2762 { "Priority": "low", "LocCode": "P0" } 2763 ] 2764 } 2765 ] 2766 }, 2767 { 2768 "ADValue": "CP1_VDN", "Callouts": [ 2769 { 2770 "CalloutList": [ 2771 { "Priority": "high", "LocCode": "P0-C12" }, 2772 { "Priority": "medium", "LocCode": "P0-C14" }, 2773 { "Priority": "low", "LocCode": "P0" } 2774 ] 2775 } 2776 ] 2777 }, 2778 { 2779 "ADValue": "CP2_VDN", "Callouts": [ 2780 { 2781 "CalloutList": [ 2782 { "Priority": "high", "LocCode": "P0-C21" }, 2783 { "Priority": "medium", "LocCode": "P0-C19" }, 2784 { "Priority": "low", "LocCode": "P0" } 2785 ] 2786 } 2787 ] 2788 }, 2789 { 2790 "ADValue": "CP3_VDN", "Callouts": [ 2791 { 2792 "CalloutList": [ 2793 { "Priority": "high", "LocCode": "P0-C54" }, 2794 { "Priority": "medium", "LocCode": "P0-C56" }, 2795 { "Priority": "low", "LocCode": "P0" } 2796 ] 2797 } 2798 ] 2799 }, 2800 { 2801 "ADValue": "CP0_VIO", "Callouts": [ 2802 { 2803 "CalloutList": [ 2804 { "Priority": "high", "LocCode": "P0-C63" }, 2805 { "Priority": "medium", "LocCode": "P0-C61" }, 2806 { "Priority": "low", "LocCode": "P0" } 2807 ] 2808 } 2809 ] 2810 }, 2811 { 2812 "ADValue": "CP1_VIO", "Callouts": [ 2813 { 2814 "CalloutList": [ 2815 { "Priority": "high", "LocCode": "P0-C12" }, 2816 { "Priority": "medium", "LocCode": "P0-C14" }, 2817 { "Priority": "low", "LocCode": "P0" } 2818 ] 2819 } 2820 ] 2821 }, 2822 { 2823 "ADValue": "CP2_VIO", "Callouts": [ 2824 { 2825 "CalloutList": [ 2826 { "Priority": "high", "LocCode": "P0-C21" }, 2827 { "Priority": "medium", "LocCode": "P0-C19" }, 2828 { "Priority": "low", "LocCode": "P0" } 2829 ] 2830 } 2831 ] 2832 }, 2833 { 2834 "ADValue": "CP3_VIO", "Callouts": [ 2835 { 2836 "CalloutList": [ 2837 { "Priority": "high", "LocCode": "P0-C54" }, 2838 { "Priority": "medium", "LocCode": "P0-C56" }, 2839 { "Priority": "low", "LocCode": "P0" } 2840 ] 2841 } 2842 ] 2843 }, 2844 { 2845 "ADValue": "CP0_VPCIE", "Callouts": [ 2846 { 2847 "CalloutList": [ 2848 { "Priority": "high", "LocCode": "P0-C58" }, 2849 { "Priority": "medium", "LocCode": "P0-C61" }, 2850 { "Priority": "low", "LocCode": "P0" } 2851 ] 2852 } 2853 ] 2854 }, 2855 { 2856 "ADValue": "CP1_VPCIE", "Callouts": [ 2857 { 2858 "CalloutList": [ 2859 { "Priority": "high", "LocCode": "P0-C16" }, 2860 { "Priority": "medium", "LocCode": "P0-C14" }, 2861 { "Priority": "low", "LocCode": "P0" } 2862 ] 2863 } 2864 ] 2865 }, 2866 { 2867 "ADValue": "CP2_VPCIE", "Callouts": [ 2868 { 2869 "CalloutList": [ 2870 { "Priority": "high", "LocCode": "P0-C16" }, 2871 { "Priority": "medium", "LocCode": "P0-C19" }, 2872 { "Priority": "low", "LocCode": "P0" } 2873 ] 2874 } 2875 ] 2876 }, 2877 { 2878 "ADValue": "CP3_VPCIE", "Callouts": [ 2879 { 2880 "CalloutList": [ 2881 { "Priority": "high", "LocCode": "P0-C58" }, 2882 { "Priority": "medium", "LocCode": "P0-C56" }, 2883 { "Priority": "low", "LocCode": "P0" } 2884 ] 2885 } 2886 ] 2887 }, 2888 { 2889 "ADValue": "12.0VCS", "Callouts": [ 2890 { 2891 "CalloutList": [ 2892 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2893 ] 2894 } 2895 ] 2896 }, 2897 { 2898 "ADValue": "3.3VCS", "Callouts": [ 2899 { 2900 "CalloutList": [ 2901 { "Priority": "high", "LocCode": "P0" } 2902 ] 2903 } 2904 ] 2905 }, 2906 { 2907 "ADValue": "1.1V_Current", "Callouts": [ 2908 { 2909 "CalloutList": [ 2910 { "Priority": "high", "LocCode": "P0" } 2911 ] 2912 } 2913 ] 2914 }, 2915 { 2916 "ADValue": "5.0V_USB_Current", "Callouts": [ 2917 { 2918 "CalloutList": [ 2919 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2920 { "Priority": "medium", "LocCode": "P0" } 2921 ] 2922 } 2923 ] 2924 }, 2925 { 2926 "ADValue": "5.0V_DASD_Current", "Callouts": [ 2927 { 2928 "CalloutList": [ 2929 { "Priority": "medium", "LocCode": "P1" }, 2930 { "Priority": "medium", "LocCode": "P2" }, 2931 { "Priority": "low", "LocCode": "P0" } 2932 ] 2933 } 2934 ] 2935 }, 2936 { 2937 "ADValue": "12.0VN", "Callouts": [ 2938 { 2939 "CalloutList": [ 2940 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2941 ] 2942 } 2943 ] 2944 }, 2945 { 2946 "ADValue": "12.0VP", "Callouts": [ 2947 { 2948 "CalloutList": [ 2949 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2950 ] 2951 } 2952 ] 2953 }, 2954 { 2955 "ADValue": "12.0VQ", "Callouts": [ 2956 { 2957 "CalloutList": [ 2958 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2959 ] 2960 } 2961 ] 2962 }, 2963 { 2964 "ADValue": "12.0VR", "Callouts": [ 2965 { 2966 "CalloutList": [ 2967 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2968 ] 2969 } 2970 ] 2971 }, 2972 { 2973 "ADValue": "ThermalDiode1", "Callouts": [ 2974 { 2975 "CalloutList": [ 2976 { "Priority": "high", "LocCode": "P0" } 2977 ] 2978 } 2979 ] 2980 }, 2981 { 2982 "ADValue": "ThermalDiode2", "Callouts": [ 2983 { 2984 "CalloutList": [ 2985 { "Priority": "high", "LocCode": "P0" } 2986 ] 2987 } 2988 ] 2989 }, 2990 { 2991 "ADValue": "ThermalDiode3", "Callouts": [ 2992 { 2993 "CalloutList": [ 2994 { "Priority": "high", "LocCode": "P0" } 2995 ] 2996 } 2997 ] 2998 }, 2999 { 3000 "ADValue": "ThermalDiode4", "Callouts": [ 3001 { 3002 "CalloutList": [ 3003 { "Priority": "high", "LocCode": "P0" } 3004 ] 3005 } 3006 ] 3007 }, 3008 { 3009 "ADValue": "VDN_DCM0", "Callouts": [ 3010 { 3011 "CalloutList": [ 3012 { "Priority": "high", "LocCode": "P0-C14" }, 3013 { "Priority": "medium", "LocCode": "P0-C15" }, 3014 { "Priority": "low", "LocCode": "P0" } 3015 ] 3016 } 3017 ] 3018 }, 3019 { 3020 "ADValue": "VDN_DCM1", "Callouts": [ 3021 { 3022 "CalloutList": [ 3023 { "Priority": "high", "LocCode": "P0-C23" }, 3024 { "Priority": "medium", "LocCode": "P0-C24" }, 3025 { "Priority": "low", "LocCode": "P0" } 3026 ] 3027 } 3028 ] 3029 }, 3030 { 3031 "ADValue": "VCS_DCM0", "Callouts": [ 3032 { 3033 "CalloutList": [ 3034 { "Priority": "high", "LocCode": "P0-C14" }, 3035 { "Priority": "medium", "LocCode": "P0-C15" }, 3036 { "Priority": "low", "LocCode": "P0" } 3037 ] 3038 } 3039 ] 3040 }, 3041 { 3042 "ADValue": "VCS_DCM1", "Callouts": [ 3043 { 3044 "CalloutList": [ 3045 { "Priority": "high", "LocCode": "P0-C23" }, 3046 { "Priority": "medium", "LocCode": "P0-C24" }, 3047 { "Priority": "low", "LocCode": "P0" } 3048 ] 3049 } 3050 ] 3051 }, 3052 { 3053 "ADValue": "VIO_DCM0", "Callouts": [ 3054 { 3055 "CalloutList": [ 3056 { "Priority": "high", "LocCode": "P0-C14" }, 3057 { "Priority": "medium", "LocCode": "P0-C15" }, 3058 { "Priority": "low", "LocCode": "P0" } 3059 ] 3060 } 3061 ] 3062 }, 3063 { 3064 "ADValue": "VIO_DCM1", "Callouts": [ 3065 { 3066 "CalloutList": [ 3067 { "Priority": "high", "LocCode": "P0-C23" }, 3068 { "Priority": "medium", "LocCode": "P0-C24" }, 3069 { "Priority": "low", "LocCode": "P0" } 3070 ] 3071 } 3072 ] 3073 }, 3074 { 3075 "ADValue": "VPCIE_DCM0", "Callouts": [ 3076 { 3077 "CalloutList": [ 3078 { "Priority": "high", "LocCode": "P0-C14" }, 3079 { "Priority": "medium", "LocCode": "P0-C15" }, 3080 { "Priority": "low", "LocCode": "P0" } 3081 ] 3082 } 3083 ] 3084 }, 3085 { 3086 "ADValue": "VPCIE_DCM1", "Callouts": [ 3087 { 3088 "CalloutList": [ 3089 { "Priority": "high", "LocCode": "P0-C23" }, 3090 { "Priority": "medium", "LocCode": "P0-C24" }, 3091 { "Priority": "low", "LocCode": "P0" } 3092 ] 3093 } 3094 ] 3095 } 3096 ] 3097 }, 3098 3099 "Documentation": { 3100 "Description": "The power sequencer chip detected a voltage fault", 3101 "Message": "The power sequencer chip detected a voltage fault", 3102 "Notes": [ 3103 ] 3104 } 3105 }, 3106 3107 { 3108 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 3109 "Subsystem": "power", 3110 "Severity": "predictive_redundancy_loss", 3111 "ComponentID": "0x2700", 3112 3113 "SRC": { 3114 "Type": "11", 3115 "ReasonCode": "0x2700", 3116 "Words6To9": {} 3117 }, 3118 3119 "Documentation": { 3120 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 3121 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 3122 "Notes": [ 3123 "CALLOUT_INVENTORY_PATH should be specified in the ", 3124 "AdditionalData property of the event log so that ", 3125 "the device is called out but not the communication path." 3126 ] 3127 } 3128 }, 3129 3130 { 3131 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 3132 "Subsystem": "power", 3133 "Severity": "non_error", 3134 "MfgSeverity": "predictive_redundancy_loss", 3135 "ActionFlags": ["report"], 3136 "MfgActionFlags": ["service_action", "report", "call_home"], 3137 "ComponentID": "0x2700", 3138 3139 "SRC": { 3140 "Type": "11", 3141 "ReasonCode": "0x2701", 3142 "Words6To9": {} 3143 }, 3144 3145 "Documentation": { 3146 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 3147 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 3148 "Notes": [ 3149 "CALLOUT_INVENTORY_PATH should be specified in the ", 3150 "AdditionalData property of the event log so that ", 3151 "the device is called out but not the communication path." 3152 ] 3153 } 3154 }, 3155 3156 { 3157 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 3158 "Subsystem": "power", 3159 "ComponentID": "0x2700", 3160 3161 "SRC": { 3162 "Type": "11", 3163 "ReasonCode": "0x2900", 3164 "Words6To9": {} 3165 }, 3166 3167 "Documentation": { 3168 "Description": "A write verification error occurred on a device", 3169 "Message": "A write verification error occurred on a device", 3170 "Notes": [ 3171 "This error occurs when a device register is written, ", 3172 "read back, and the two values do not match. This is ", 3173 "also called a read-back error. The device should be ", 3174 "identified using the CALLOUT_DEVICE_PATH or ", 3175 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 3176 "AdditionalData property of the event log. This will ", 3177 "cause the device and the hardware in the communication ", 3178 "path to be called out." 3179 ] 3180 } 3181 }, 3182 3183 { 3184 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Discharging", 3185 "Subsystem": "power", 3186 "Severity": "non_error", 3187 "ActionFlags": ["report"], 3188 "ComponentID": "0x2700", 3189 3190 "SRC": { 3191 "Type": "11", 3192 "ReasonCode": "0x4201", 3193 "Words6To9": {} 3194 }, 3195 3196 "Documentation": { 3197 "Description": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 3198 "Message": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 3199 "Notes": [ 3200 ] 3201 } 3202 }, 3203 3204 { 3205 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Low", 3206 "Subsystem": "power", 3207 "Severity": "non_error", 3208 "ActionFlags": ["report"], 3209 "ComponentID": "0x2700", 3210 3211 "SRC": { 3212 "Type": "11", 3213 "ReasonCode": "0x4203", 3214 "Words6To9": {} 3215 }, 3216 3217 "Documentation": { 3218 "Description": "The Uninterruptible Power Supply (UPS) battery level is low", 3219 "Message": "The Uninterruptible Power Supply (UPS) battery level is low", 3220 "Notes": [ 3221 ] 3222 } 3223 }, 3224 3225 { 3226 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 3227 "Subsystem": "power", 3228 "ComponentID": "0x2700", 3229 3230 "SRC": { 3231 "Type": "11", 3232 "ReasonCode": "0xA013", 3233 "Words6To9": {} 3234 }, 3235 3236 "Callouts": [ 3237 { 3238 "CalloutList": [ 3239 { "Priority": "high", "Procedure": "bmc_code" } 3240 ] 3241 } 3242 ], 3243 3244 "Documentation": { 3245 "Description": "A regulators configuration file error occurred", 3246 "Message": "A regulators configuration file error occurred", 3247 "Notes": [ 3248 "The regulators configuration file could not be found, ", 3249 "could not be read, or had invalid contents." 3250 ] 3251 } 3252 }, 3253 3254 { 3255 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 3256 "Subsystem": "power", 3257 "Severity": "critical_system_term", 3258 "ComponentID": "0x2700", 3259 3260 "SRC": { 3261 "Type": "11", 3262 "ReasonCode": "0xA014", 3263 "Words6To9": {} 3264 }, 3265 3266 "Callouts": [ 3267 { 3268 "CalloutList": [ 3269 { "Priority": "high", "Procedure": "bmc_code" } 3270 ] 3271 } 3272 ], 3273 3274 "Documentation": { 3275 "Description": "A critical regulators configuration file error occurred", 3276 "Message": "A critical regulators configuration file error occurred", 3277 "Notes": [ 3278 "The regulators configuration file could not be found, ", 3279 "could not be read, or had invalid contents. As a result ", 3280 "voltage regulators could not be configured, and the ", 3281 "chassis could not be powered on." 3282 ] 3283 } 3284 }, 3285 3286 { 3287 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 3288 "Subsystem": "power_sequencer", 3289 "ComponentID": "0x2700", 3290 3291 "SRC": { 3292 "Type": "11", 3293 "ReasonCode": "0xD000", 3294 "Words6To9": {} 3295 }, 3296 3297 "Callouts": [ 3298 { 3299 "CalloutList": [ 3300 { "Priority": "high", "LocCode": "P0" } 3301 ] 3302 } 3303 ], 3304 3305 "Documentation": { 3306 "Description": "The power sequencer chip detected a fault", 3307 "Message": "The power sequencer chip detected a fault", 3308 "Notes": [ 3309 ] 3310 } 3311 }, 3312 3313 { 3314 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 3315 "Subsystem": "power_sequencer", 3316 "ComponentID": "0x2700", 3317 "Severity": "critical", 3318 3319 "SRC": { 3320 "Type": "11", 3321 "ReasonCode": "0xD002", 3322 "Words6To9": {} 3323 }, 3324 3325 "Callouts": [ 3326 { 3327 "CalloutList": [ 3328 { "Priority": "high", "LocCode": "P0" } 3329 ] 3330 } 3331 ], 3332 3333 "Documentation": { 3334 "Description": "System power failed to turn on within timeout period", 3335 "Message": "System power failed to turn on within timeout period", 3336 "Notes": [ 3337 ] 3338 } 3339 }, 3340 3341 { 3342 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 3343 "Subsystem": "power_sequencer", 3344 "ComponentID": "0x2700", 3345 "Severity": "critical", 3346 3347 "SRC": { 3348 "Type": "11", 3349 "ReasonCode": "0xD008", 3350 "Words6To9": {} 3351 }, 3352 3353 "Callouts": [ 3354 { 3355 "CalloutList": [ 3356 { "Priority": "high", "LocCode": "P0" } 3357 ] 3358 } 3359 ], 3360 3361 "Documentation": { 3362 "Description": "System power failed to turn off within timeout period", 3363 "Message": "System power failed to turn off within timeout period", 3364 "Notes": [ 3365 ] 3366 } 3367 }, 3368 3369 { 3370 "Name": "xyz.openbmc_project.Power.Error.Internal", 3371 "Subsystem": "power", 3372 "ComponentID": "0x2700", 3373 3374 "SRC": { 3375 "Type": "11", 3376 "ReasonCode": "0xE000", 3377 "Words6To9": {} 3378 }, 3379 3380 "Callouts": [ 3381 { 3382 "CalloutList": [ 3383 { "Priority": "high", "Procedure": "bmc_code" } 3384 ] 3385 } 3386 ], 3387 3388 "Documentation": { 3389 "Description": "An internal firmware error occurred", 3390 "Message": "An internal firmware error occurred", 3391 "Notes": [ 3392 "The error details must be provided in the AdditionalData ", 3393 "property of the event log." 3394 ] 3395 } 3396 }, 3397 3398 { 3399 "Name": "xyz.openbmc_project.Power.Error.I2C", 3400 "Subsystem": "cec_i2c", 3401 "ComponentID": "0x2700", 3402 3403 "SRC": { 3404 "Type": "11", 3405 "ReasonCode": "0xE100", 3406 "Words6To9": {} 3407 }, 3408 3409 "Documentation": { 3410 "Description": "An I2C error occurred communicating with a device", 3411 "Message": "An I2C error occurred communicating with a device", 3412 "Notes": [ 3413 "The device should be identified using the ", 3414 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 3415 "keywords in the AdditionalData property of the event ", 3416 "log. This will cause the device and the hardware in the ", 3417 "communication path to be called out." 3418 ] 3419 } 3420 }, 3421 3422 { 3423 "Name": "xyz.openbmc_project.Power.Error.PMBus", 3424 "Subsystem": "power", 3425 "ComponentID": "0x2700", 3426 3427 "SRC": { 3428 "Type": "11", 3429 "ReasonCode": "0xE200", 3430 "Words6To9": {} 3431 }, 3432 3433 "Documentation": { 3434 "Description": "A PMBus error occurred on a device", 3435 "Message": "A PMBus error occurred on a device", 3436 "Notes": [ 3437 "This error occurs when the I2C communication was ", 3438 "successful, but the PMBus value read is invalid or ", 3439 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 3440 "in the AdditionalData property of the event log so that ", 3441 "the device is called out but not the communication path." 3442 ] 3443 } 3444 }, 3445 3446 { 3447 "Name": "xyz.openbmc_project.Power.Error.DBus", 3448 "Subsystem": "power", 3449 "ComponentID": "0x2700", 3450 3451 "SRC": { 3452 "Type": "11", 3453 "ReasonCode": "0xE300", 3454 "Words6To9": {} 3455 }, 3456 3457 "Callouts": [ 3458 { 3459 "CalloutList": [ 3460 { "Priority": "high", "Procedure": "bmc_code" } 3461 ] 3462 } 3463 ], 3464 3465 "Documentation": { 3466 "Description": "A firmware inter-process communication (D-Bus) error occurred", 3467 "Message": "A firmware inter-process communication (D-Bus) error occurred" 3468 } 3469 }, 3470 3471 { 3472 "Name": "xyz.openbmc_project.Fan.Error.Fault", 3473 "Subsystem": "power_fans", 3474 "ComponentID": "0x2800", 3475 3476 "SRC": { 3477 "Type": "11", 3478 "ReasonCode": "0x76F0", 3479 "Words6To9": {} 3480 }, 3481 3482 "Documentation": { 3483 "Description": "Fan rotor fault", 3484 "Message": "Fan rotor fault", 3485 "Notes": [ 3486 "This error occurs when a fan rotor has been faulted for a ", 3487 "certain amount of time. The callout is the fan which is ", 3488 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 3489 "passed in during creation and will be either informational ", 3490 "or unrecoverable. The action flags use the defaults and ", 3491 "vary based on the severity." 3492 ] 3493 } 3494 }, 3495 3496 { 3497 "Name": "xyz.openbmc_project.Fan.Error.Missing", 3498 "Subsystem": "power_fans", 3499 "ComponentID": "0x2800", 3500 "Severity": "unrecoverable_redundancy_loss", 3501 "ActionFlags": ["service_action", "report", "call_home"], 3502 3503 "SRC": { 3504 "Type": "11", 3505 "ReasonCode": "0x76F1", 3506 "Words6To9": {} 3507 }, 3508 3509 "Callouts": [ 3510 { 3511 "System": "ibm,rainier", 3512 "CalloutList": [ 3513 { 3514 "Priority": "high", 3515 "SymbolicFRUTrusted": "air_mover", 3516 "UseInventoryLocCode": true 3517 }, 3518 { 3519 "Priority": "low", 3520 "LocCode": "P0" 3521 } 3522 ] 3523 }, 3524 { 3525 "System": "ibm,everest", 3526 "CalloutList": [ 3527 { 3528 "Priority": "high", 3529 "SymbolicFRUTrusted": "air_mover", 3530 "UseInventoryLocCode": true 3531 }, 3532 { 3533 "Priority": "low", 3534 "LocCode": "P1" 3535 } 3536 ] 3537 } 3538 ], 3539 3540 "Documentation": { 3541 "Description": "A fan is missing", 3542 "Message": "A fan is missing", 3543 "Notes": [ 3544 "This error occurs when a fan has been missing for a ", 3545 "certain amount of time. The first callout is the ", 3546 "symbolic FRU AIR_MOVR that has the trusted fan location ", 3547 "code, which it gets using the passed in ", 3548 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 3549 "where the controller and GPIO expander are." 3550 ] 3551 } 3552 }, 3553 3554 { 3555 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 3556 "ComponentID": "0x2800", 3557 "Subsystem": "power_fans", 3558 "Severity": "non_error", 3559 "ActionFlags": ["report"], 3560 "MfgSeverity": "predictive", 3561 "MfgActionFlags": ["service_action", "report"], 3562 3563 "SRC": { 3564 "Type": "11", 3565 "ReasonCode": "0x76F2", 3566 "Words6To9": {} 3567 }, 3568 3569 "Callouts": [ 3570 { 3571 "System": "ibm,rainier", 3572 "CalloutList": [ 3573 {"Priority": "medium", "LocCode": "P0"} 3574 ] 3575 }, 3576 { 3577 "System": "ibm,everest", 3578 "CalloutList": [ 3579 {"Priority": "medium", "LocCode": "P1"} 3580 ] 3581 } 3582 ], 3583 3584 "Documentation": { 3585 "Description": "Presence detect methods for the same fan disagree", 3586 "Message": "Presence detect methods for the same fan disagree", 3587 "Notes": [ 3588 "This error occurs when there is more than one way to detect", 3589 "fan presence, and they don't all agree. For example, the", 3590 "GPIO says a fan isn't present, but the tach readings are", 3591 "nonzero. This is informational, unless in manufacturing.", 3592 "The fan FRU is passed in as a high priority callout.", 3593 "The FRU the GPIO source is on is called out medium." 3594 ] 3595 } 3596 }, 3597 3598 { 3599 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 3600 "ComponentID": "0x2800", 3601 "Subsystem": "power_fans", 3602 "Severity": "critical_system_term", 3603 "ActionFlags": ["service_action", "report", "call_home"], 3604 3605 "SRC": { 3606 "Type": "11", 3607 "ReasonCode": "0x76F3", 3608 "Words6To9": {} 3609 }, 3610 3611 "Callouts": [ 3612 { 3613 "System": "ibm,rainier", 3614 "CalloutList": [ 3615 {"Priority": "high", "LocCode": "P0-C5"}, 3616 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 3617 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 3618 {"Priority": "low", "LocCode": "P0"} 3619 ] 3620 }, 3621 { 3622 "System": "ibm,everest", 3623 "CalloutList": [ 3624 {"Priority": "high", "LocCode": "P0-C0"}, 3625 {"Priority": "medium", "LocCode": "P1"}, 3626 {"Priority": "low", "LocCode": "P0"} 3627 ] 3628 } 3629 ], 3630 3631 "Documentation": { 3632 "Description": "The fan controller device is offline", 3633 "Message": "The fan controller is offline. The system must be powered off.", 3634 "Notes": [ 3635 "The device that controls the fans is offline so the fan", 3636 "targets and speeds are unknown. The system will be shut", 3637 "down to preserve thermal safety. There may be an I2C", 3638 "or power problem with the device." 3639 ] 3640 } 3641 }, 3642 3643 { 3644 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 3645 "Subsystem": "power_fans", 3646 "ComponentID": "0x2800", 3647 "Severity": "unrecoverable_redundancy_loss", 3648 "ActionFlags": ["service_action", "report", "call_home"], 3649 3650 "SRC": { 3651 "Type": "11", 3652 "ReasonCode": "0x76F4", 3653 "Words6To9": {} 3654 }, 3655 3656 "Callouts": [ 3657 { 3658 "System" : "ibm,rainier", 3659 "CalloutList": [ 3660 {"Priority": "high", "LocCode": "P0-C5"}, 3661 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 3662 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 3663 {"Priority": "low", "LocCode": "P0"} 3664 ] 3665 }, 3666 { 3667 "System" : "ibm,everest", 3668 "CalloutList": [ 3669 {"Priority": "high", "LocCode": "P0-C0"}, 3670 {"Priority": "medium", "LocCode": "P1"}, 3671 {"Priority": "low", "LocCode": "P0"} 3672 ] 3673 } 3674 ], 3675 3676 "Documentation": { 3677 "Description": "Fan GPIO sensors not present", 3678 "Message": "Fan GPIO sensors not present", 3679 "Notes": [ 3680 "The device that reports fan presence is not functioning." 3681 ] 3682 } 3683 }, 3684 3685 { 3686 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 3687 "Subsystem": "power", 3688 "ComponentID": "0x2800", 3689 "Severity": "predictive", 3690 "ActionFlags": ["service_action", "report"], 3691 3692 "SRC": { 3693 "ReasonCode": "0x2801", 3694 "Words6To9": {} 3695 }, 3696 3697 "CalloutsUsingAD": { 3698 "ADName": "SENSOR_NAME", 3699 "CalloutsWithTheirADValues": [ 3700 { 3701 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3702 "Callouts": [ 3703 { 3704 "CalloutList": [ 3705 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3706 ] 3707 } 3708 ] 3709 } 3710 ] 3711 }, 3712 3713 "Documentation": { 3714 "Description": "A temperature sensor exceeded its performance loss threshold.", 3715 "Message": "A temperature sensor exceeded its performance loss threshold.", 3716 "Notes": [ 3717 "A temperature sensor crossed its performance loss threshold value", 3718 "If it is the ambient sensor, then a symbolic FRU will be added.", 3719 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3720 "a FRU callout." 3721 ] 3722 } 3723 }, 3724 3725 { 3726 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 3727 "Subsystem": "power", 3728 "ComponentID": "0x2800", 3729 "Severity": "non_error", 3730 "ActionFlags": ["report"], 3731 "EventType": "env_normal", 3732 3733 "SRC": { 3734 "ReasonCode": "0x2802", 3735 "Words6To9": {} 3736 }, 3737 3738 "CalloutsUsingAD": { 3739 "ADName": "SENSOR_NAME", 3740 "CalloutsWithTheirADValues": [ 3741 { 3742 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3743 "Callouts": [ 3744 { 3745 "CalloutList": [ 3746 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3747 ] 3748 } 3749 ] 3750 } 3751 ] 3752 }, 3753 3754 "Documentation": { 3755 "Description": "A temperature sensor is under its performance loss threshold.", 3756 "Message": "A temperature sensor is under its performance loss threshold.", 3757 "Notes": [ 3758 "A temperature sensor crossed under its performance loss threshold value", 3759 "If it is the ambient sensor, then a symbolic FRU will be added." 3760 ] 3761 } 3762 }, 3763 3764 { 3765 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 3766 "Subsystem": "power", 3767 "ComponentID": "0x2800", 3768 "Severity": "predictive", 3769 "ActionFlags": ["service_action", "report"], 3770 3771 "SRC": { 3772 "ReasonCode": "0x2803", 3773 "Words6To9": {} 3774 }, 3775 3776 "CalloutsUsingAD": { 3777 "ADName": "SENSOR_NAME", 3778 "CalloutsWithTheirADValues": [ 3779 { 3780 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3781 "Callouts": [ 3782 { 3783 "CalloutList": [ 3784 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3785 ] 3786 } 3787 ] 3788 } 3789 ] 3790 }, 3791 3792 "Documentation": { 3793 "Description": "A temperature sensor exceeded its warning threshold.", 3794 "Message": "A temperature sensor exceeded its warning threshold.", 3795 "Notes": [ 3796 "A temperature sensor crossed its warning threshold value", 3797 "If it is the ambient sensor, then a symbolic FRU will be added.", 3798 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3799 "a FRU callout." 3800 ] 3801 } 3802 }, 3803 3804 { 3805 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 3806 "Subsystem": "power", 3807 "ComponentID": "0x2800", 3808 "Severity": "non_error", 3809 "ActionFlags": ["report"], 3810 "EventType": "env_normal", 3811 3812 "SRC": { 3813 "ReasonCode": "0x2804", 3814 "Words6To9": {} 3815 }, 3816 3817 "CalloutsUsingAD": { 3818 "ADName": "SENSOR_NAME", 3819 "CalloutsWithTheirADValues": [ 3820 { 3821 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3822 "Callouts": [ 3823 { 3824 "CalloutList": [ 3825 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3826 ] 3827 } 3828 ] 3829 } 3830 ] 3831 }, 3832 3833 "Documentation": { 3834 "Description": "A temperature sensor is under its warning threshold.", 3835 "Message": "A temperature sensor is under its warning threshold.", 3836 "Notes": [ 3837 "A temperature sensor crossed under its warning threshold value", 3838 "If it is the ambient sensor, then a symbolic FRU will be added." 3839 ] 3840 } 3841 }, 3842 3843 { 3844 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 3845 "Subsystem": "power", 3846 "ComponentID": "0x2800", 3847 "Severity": "predictive", 3848 "ActionFlags": ["service_action", "report"], 3849 3850 "SRC": { 3851 "ReasonCode": "0x2805", 3852 "Words6To9": {} 3853 }, 3854 3855 "CalloutsUsingAD": { 3856 "ADName": "SENSOR_NAME", 3857 "CalloutsWithTheirADValues": [ 3858 { 3859 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3860 "Callouts": [ 3861 { 3862 "CalloutList": [ 3863 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3864 ] 3865 } 3866 ] 3867 } 3868 ] 3869 }, 3870 3871 "Documentation": { 3872 "Description": "A temperature sensor exceeded its critical threshold.", 3873 "Message": "A temperature sensor exceeded its critical threshold.", 3874 "Notes": [ 3875 "A temperature sensor crossed its critical threshold value", 3876 "If it is the ambient sensor, then a symbolic FRU will be added.", 3877 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3878 "a FRU callout." 3879 ] 3880 } 3881 }, 3882 3883 { 3884 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 3885 "Subsystem": "power", 3886 "ComponentID": "0x2800", 3887 "Severity": "non_error", 3888 "ActionFlags": ["report"], 3889 "EventType": "env_normal", 3890 3891 "SRC": { 3892 "ReasonCode": "0x2806", 3893 "Words6To9": {} 3894 }, 3895 3896 "CalloutsUsingAD": { 3897 "ADName": "SENSOR_NAME", 3898 "CalloutsWithTheirADValues": [ 3899 { 3900 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3901 "Callouts": [ 3902 { 3903 "CalloutList": [ 3904 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3905 ] 3906 } 3907 ] 3908 } 3909 ] 3910 }, 3911 3912 "Documentation": { 3913 "Description": "A temperature sensor is under its critical threshold.", 3914 "Message": "A temperature sensor is under its critical threshold.", 3915 "Notes": [ 3916 "A temperature sensor crossed under its critical threshold value", 3917 "If it is the ambient sensor, then a symbolic FRU will be added." 3918 ] 3919 } 3920 }, 3921 3922 { 3923 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 3924 "Subsystem": "power", 3925 "ComponentID": "0x2800", 3926 "Severity": "predictive", 3927 "ActionFlags": ["service_action", "report"], 3928 3929 "SRC": { 3930 "ReasonCode": "0x2807", 3931 "Words6To9": {} 3932 }, 3933 3934 "Callouts": [ 3935 { 3936 "CalloutList": [ 3937 { 3938 "Priority": "high", 3939 "SymbolicFRU": "ambient_temp" 3940 } 3941 ] 3942 } 3943 ], 3944 3945 "Documentation": { 3946 "Description": "The ambient temperature passed the EPOW3 limit.", 3947 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 3948 "Notes": [ 3949 "This error occurs when the ambient temperature surpassed", 3950 "the EPOW3 shutdown limit." 3951 ] 3952 } 3953 }, 3954 3955 { 3956 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 3957 "Subsystem": "power", 3958 "ComponentID": "0x2800", 3959 "Severity": "non_error", 3960 "ActionFlags": ["report"], 3961 "EventType": "env_normal", 3962 3963 "SRC": { 3964 "ReasonCode": "0x2808", 3965 "Words6To9": {} 3966 }, 3967 3968 "Callouts": [ 3969 { 3970 "CalloutList": [ 3971 { 3972 "Priority": "high", 3973 "SymbolicFRU": "ambient_temp_back" 3974 } 3975 ] 3976 } 3977 ], 3978 3979 "Documentation": { 3980 "Description": "The ambient temperature is back under the EPOW3 limit.", 3981 "Message": "The ambient temperature is back under the EPOW3 limit." 3982 } 3983 }, 3984 3985 { 3986 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 3987 "Subsystem": "power", 3988 "ComponentID": "0x2800", 3989 "ActionFlags": ["service_action", "report"], 3990 3991 "SRC": { 3992 "ReasonCode": "0x2809", 3993 "Words6To9": {} 3994 }, 3995 3996 "Callouts": [ 3997 { 3998 "CalloutList": [ 3999 { 4000 "Priority": "high", 4001 "SymbolicFRU": "ambient_temp" 4002 } 4003 ] 4004 } 4005 ], 4006 4007 "Documentation": { 4008 "Description": "The ambient temperature passed the EPOW4 limit.", 4009 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 4010 "Notes": [ 4011 "This error occurs when the ambient temperature surpassed", 4012 "the EPOW4 shutdown limit." 4013 ] 4014 } 4015 }, 4016 4017 { 4018 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 4019 "Subsystem": "ext_env", 4020 "ComponentID": "0x2800", 4021 "Severity": "predictive", 4022 "ActionFlags": ["service_action", "report"], 4023 4024 "SRC": { 4025 "ReasonCode": "0x280A", 4026 "Words6To9": {} 4027 }, 4028 4029 "CalloutsUsingAD": { 4030 "ADName": "SENSOR_NAME", 4031 "CalloutsWithTheirADValues": [ 4032 { 4033 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 4034 "Callouts": [ 4035 { 4036 "CalloutList": [ 4037 { "Priority": "high", "SymbolicFRU": "altitude" } 4038 ] 4039 } 4040 ] 4041 } 4042 ] 4043 }, 4044 4045 "Documentation": { 4046 "Description": "An altitude sensor exceeded its warning threshold.", 4047 "Message": "An altitude sensor exceeded its warning threshold.", 4048 "Notes": [ 4049 "The virtual altitude sensor crossed its warning threshold value", 4050 " and a symbolic FRU will be added." 4051 ] 4052 } 4053 }, 4054 4055 { 4056 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 4057 "Subsystem": "ext_env", 4058 "ComponentID": "0x2800", 4059 "Severity": "non_error", 4060 "ActionFlags": ["report"], 4061 "EventType": "env_normal", 4062 4063 "SRC": { 4064 "ReasonCode": "0x280B", 4065 "Words6To9": {} 4066 }, 4067 4068 "Documentation": { 4069 "Description": "An altitude sensor is under its warning threshold.", 4070 "Message": "An altitude sensor is under its warning threshold.", 4071 "Notes": [ 4072 "The virtual altitude sensor is under its warning threshold value", 4073 " and a symbolic FRU will be added." 4074 ] 4075 } 4076 }, 4077 4078 { 4079 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 4080 "Subsystem": "cec_tod", 4081 "ComponentID": "0x2800", 4082 "Severity": "predictive", 4083 "ActionFlags": ["service_action", "report"], 4084 4085 "SRC": { 4086 "ReasonCode": "0x280C", 4087 "Words6To9": {} 4088 }, 4089 4090 "Documentation": { 4091 "Description": "A voltage sensor went below its critical low threshold.", 4092 "Message": "A voltage sensor went below its critical low threshold." 4093 } 4094 }, 4095 4096 { 4097 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 4098 "Subsystem": "cec_tod", 4099 "ComponentID": "0x2800", 4100 "Severity": "non_error", 4101 "ActionFlags": ["report"], 4102 4103 "SRC": { 4104 "ReasonCode": "0x280D", 4105 "Words6To9": {} 4106 }, 4107 4108 "Documentation": { 4109 "Description": "A voltage sensor is over its critical low threshold.", 4110 "Message": "A voltage sensor is over its critical low threshold." 4111 } 4112 }, 4113 4114 { 4115 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLow", 4116 "Subsystem": "power", 4117 "ComponentID": "0x2800", 4118 "Severity": "predictive", 4119 "ActionFlags": ["service_action", "report"], 4120 4121 "SRC": { 4122 "ReasonCode": "0x280E", 4123 "Words6To9": {} 4124 }, 4125 4126 "Documentation": { 4127 "Description": "A temperature sensor is under its low warning threshold.", 4128 "Message": "A temperature sensor is under its low warning threshold.", 4129 "Notes": [ 4130 "A temperature sensor crossed its low warning threshold value", 4131 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 4132 ] 4133 } 4134 }, 4135 4136 { 4137 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLowClear", 4138 "Subsystem": "power", 4139 "ComponentID": "0x2800", 4140 "Severity": "non_error", 4141 "ActionFlags": ["report"], 4142 "EventType": "env_normal", 4143 4144 "SRC": { 4145 "ReasonCode": "0x280F", 4146 "Words6To9": {} 4147 }, 4148 4149 "Documentation": { 4150 "Description": "A temperature sensor is above its low warning threshold.", 4151 "Message": "A temperature sensor is above its low warning threshold.", 4152 "Notes": [ 4153 "A temperature sensor crossed above its low warning threshold value." 4154 ] 4155 } 4156 }, 4157 4158 { 4159 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLow", 4160 "Subsystem": "power", 4161 "ComponentID": "0x2800", 4162 "Severity": "predictive", 4163 "ActionFlags": ["service_action", "report"], 4164 4165 "SRC": { 4166 "ReasonCode": "0x2810", 4167 "Words6To9": {} 4168 }, 4169 4170 "Documentation": { 4171 "Description": "A temperature sensor is under its low critical threshold.", 4172 "Message": "A temperature sensor is under its low critical threshold.", 4173 "Notes": [ 4174 "A temperature sensor crossed its low critical threshold value", 4175 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 4176 ] 4177 } 4178 }, 4179 4180 { 4181 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLowClear", 4182 "Subsystem": "power", 4183 "ComponentID": "0x2800", 4184 "Severity": "non_error", 4185 "ActionFlags": ["report"], 4186 "EventType": "env_normal", 4187 4188 "SRC": { 4189 "ReasonCode": "0x2811", 4190 "Words6To9": {} 4191 }, 4192 4193 "Documentation": { 4194 "Description": "A temperature sensor is over its low critical threshold.", 4195 "Message": "A temperature sensor is over its low critical threshold.", 4196 "Notes": [ 4197 "A temperature sensor crossed above its critical threshold value" 4198 ] 4199 } 4200 }, 4201 4202 { 4203 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 4204 "Subsystem": "cec_vpd", 4205 "ComponentID": "0x4000", 4206 4207 "SRC": { 4208 "ReasonCode": "0x4000", 4209 "Words6To9": 4210 { 4211 "6": 4212 { 4213 "Description": "Errno of the failure.", 4214 "AdditionalDataPropSource": "CALLOUT_ERRNO" 4215 } 4216 } 4217 }, 4218 4219 "Documentation": { 4220 "Description": "A path access error occurred", 4221 "Message": "An EEPROM path access error occurred.", 4222 "Notes": [ 4223 "This error occurs when parser is unable to access", 4224 "EEPROM path. Errno and device path are captured as", 4225 "additional data." 4226 ] 4227 } 4228 }, 4229 4230 { 4231 "Name": "com.ibm.VPD.Error.InvalidVPD", 4232 "Subsystem": "cec_vpd", 4233 "ComponentID": "0x4000", 4234 4235 "SRC": { 4236 "ReasonCode": "0x4001", 4237 "Words6To9": 4238 { 4239 } 4240 }, 4241 4242 "Documentation": { 4243 "Description": "Invalid VPD data.", 4244 "Message": "A VPD data exception occurred.", 4245 "Notes": [ 4246 "This error occurs when VPD data is found to be", 4247 "invalid. This can be when VPD file is missing out", 4248 "mandatory records.Inventory path is captured in", 4249 "additional data." 4250 ] 4251 } 4252 }, 4253 4254 { 4255 "Name": "com.ibm.VPD.Error.EccCheckFailed", 4256 "Subsystem": "cec_vpd", 4257 "ComponentID": "0x4000", 4258 4259 "SRC": { 4260 "ReasonCode": "0x4002", 4261 "Words6To9": 4262 { 4263 } 4264 }, 4265 4266 "Documentation": { 4267 "Description": "Invalid VPD ecc data.", 4268 "Message": "A VPD ecc exception occurred.", 4269 "Notes": [ 4270 "This error occurs when VPD ecc check fails for the FRU.", 4271 "Inventory path for the failed FRU is captured in additonal", 4272 "data." 4273 ] 4274 } 4275 }, 4276 4277 { 4278 "Name": "com.ibm.VPD.Error.InvalidJson", 4279 "Subsystem": "cec_vpd", 4280 "ComponentID": "0x4000", 4281 4282 "SRC": { 4283 "ReasonCode": "0x4003", 4284 "Words6To9": 4285 { 4286 } 4287 }, 4288 4289 "Callouts": [ 4290 { 4291 "CalloutList": [ 4292 { "Priority": "high", "Procedure": "bmc_code" } 4293 ] 4294 } 4295 ], 4296 4297 "Documentation": { 4298 "Description": "Invalid Json", 4299 "Message": "A Json failure occurred.", 4300 "Notes": [ 4301 "This error occurs when parser fails to access", 4302 "Json file or there is any issue with Json data.", 4303 "Failed Json path and cause of failure is captured", 4304 "in additional data." 4305 ] 4306 } 4307 }, 4308 4309 { 4310 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 4311 "Subsystem": "cec_vpd", 4312 "ComponentID": "0x4000", 4313 4314 "SRC": { 4315 "ReasonCode": "0x4004", 4316 "Words6To9": 4317 { 4318 } 4319 }, 4320 4321 "Documentation": { 4322 "Description": "System VPD restore failed", 4323 "Message": "A system VPD restoration error occurred.", 4324 "Notes": [ 4325 "This error occurs when restoring of system VPD fails.", 4326 "The FRU path and reason for failure is captured in", 4327 "additional data." 4328 ] 4329 } 4330 }, 4331 4332 { 4333 "Name": "com.ibm.VPD.Error.DbusFailure", 4334 "Subsystem": "cec_vpd", 4335 "ComponentID": "0x4000", 4336 4337 "SRC": { 4338 "ReasonCode": "0x4005", 4339 "Words6To9": 4340 { 4341 } 4342 }, 4343 4344 "Callouts": [ 4345 { 4346 "CalloutList": [ 4347 { "Priority": "high", "Procedure": "bmc_code" } 4348 ] 4349 } 4350 ], 4351 4352 "Documentation": { 4353 "Description": "Dbus exception", 4354 "Message": "A Dbus internal error occurred.", 4355 "Notes": [ 4356 "This error occurs when Dbus operation fails.", 4357 "Exceptions details are captured in additonal", 4358 "data." 4359 ] 4360 } 4361 }, 4362 4363 { 4364 "Name": "com.ibm.VPD.Error.UnknownSystemType", 4365 "Subsystem": "cec_vpd", 4366 "ComponentID": "0x4000", 4367 4368 "SRC": { 4369 "ReasonCode": "0x4006", 4370 "Words6To9": 4371 { 4372 } 4373 }, 4374 4375 "Callouts": [ 4376 { 4377 "CalloutList": [ 4378 { "Priority": "high", "LocCode": "P0" } 4379 ] 4380 } 4381 ], 4382 4383 "Documentation": { 4384 "Description": "Unknown System Type", 4385 "Message": "System type not supported in DTB table.", 4386 "Notes": [ 4387 "System type comes from combination of HW and IM value of system VPD.", 4388 "If anything gets changed in that combination, then it can't determine", 4389 "the appropriate DTB for that system. Need to check HW and IM keywords." 4390 ] 4391 } 4392 }, 4393 4394 { 4395 "Name": "com.ibm.VPD.Error.GPIOError", 4396 "Subsystem": "cec_vpd", 4397 "ComponentID": "0x4000", 4398 4399 "SRC": { 4400 "ReasonCode": "0x4007", 4401 "Words6To9": 4402 { 4403 } 4404 }, 4405 4406 "Callouts": [ 4407 { 4408 "CalloutList": [ 4409 { "Priority": "high", "Procedure": "bmc_code" } 4410 ] 4411 } 4412 ], 4413 4414 "Documentation": { 4415 "Description": "GPIO line error", 4416 "Message": "GPIO line couldn't be found or read.", 4417 "Notes": [ 4418 "The BMC could not access a GPIO line. This can be a hardware issue", 4419 " or driver issue. Since a hardware or a software issue cannot be", 4420 " differentiated, the BMC code will be called out." 4421 ] 4422 } 4423 }, 4424 4425 { 4426 "Name": "com.ibm.VPD.Error.SystemVPDMismatch", 4427 "Subsystem": "cec_vpd", 4428 "ComponentID": "0x4000", 4429 4430 "SRC": { 4431 "ReasonCode": "0x4008", 4432 "Words6To9": 4433 { 4434 } 4435 }, 4436 4437 "Callouts": [ 4438 { 4439 "CalloutList": [ 4440 { "Priority": "high", "Procedure": "bmc_code" } 4441 ] 4442 } 4443 ], 4444 4445 "Documentation": { 4446 "Description": "System VPD restore failed", 4447 "Message": "A system VPD restoration error occurred.", 4448 "Notes": [ 4449 "This error occurs when restoring of system VPD fails due to", 4450 "mismatch in cache data and hardware data.", 4451 "The record and keyword causing the failure is captured in", 4452 "additional data." 4453 ] 4454 } 4455 }, 4456 4457 { 4458 "Name": "com.ibm.VPD.Error.RequiredFRUMissing", 4459 "Subsystem": "cec_vpd", 4460 "ComponentID": "0x4000", 4461 4462 "SRC": { 4463 "ReasonCode": "0x4009", 4464 "Words6To9": 4465 { 4466 } 4467 }, 4468 4469 "Documentation": { 4470 "Description": "Essential FRU check.", 4471 "Message": "Essential FRU check failed", 4472 "Notes": [ 4473 "This error occurs when VPD manager service detects any", 4474 "missing essential FRU. These are FRUs which are required", 4475 "to be present in the system at the time of power on.", 4476 "The inventory path is captured in additional data." 4477 ] 4478 } 4479 }, 4480 4481 { 4482 "Name": "com.ibm.Panel.Error.InputDevPathFailure", 4483 "Subsystem": "cec_op_panel", 4484 "ComponentID": "0x5000", 4485 4486 "SRC": { 4487 "ReasonCode": "0x5001", 4488 "Words6To9": {} 4489 }, 4490 4491 "Documentation": { 4492 "Description": "Button Handler Failure", 4493 "Message": "Input Device path failure", 4494 "Notes": [ 4495 "Button events will not be processed." 4496 ] 4497 } 4498 }, 4499 4500 { 4501 "Name": "com.ibm.Panel.Error.I2CSetupFailure", 4502 "Subsystem": "cec_op_panel", 4503 "ComponentID": "0x5000", 4504 4505 "SRC": { 4506 "ReasonCode": "0x5002", 4507 "Words6To9": {} 4508 }, 4509 4510 "Documentation": { 4511 "Description": "Panel I2C setup failure", 4512 "Message": "Unable to open device path or ioctl failure", 4513 "Notes": [ 4514 "The Panel is unable to open device", 4515 " path or ioctl failure" 4516 ] 4517 } 4518 }, 4519 4520 { 4521 "Name": "com.ibm.Panel.Error.HostCommunicationError", 4522 "Subsystem": "cec_op_panel", 4523 "ComponentID": "0x5000", 4524 4525 "SRC": { 4526 "ReasonCode": "0x5003", 4527 "Words6To9": {} 4528 }, 4529 4530 "Callouts": [{ 4531 "CalloutList": [{ 4532 "Priority": "high", 4533 "Procedure": "bmc_code" 4534 }] 4535 }], 4536 4537 "Documentation": { 4538 "Description": "Host Communication failure", 4539 "Message": "Error in sending message to host", 4540 "Notes": [ 4541 "Failure from PLDM sending message to", 4542 "Host" 4543 ] 4544 } 4545 }, 4546 4547 { 4548 "Name": "com.ibm.Panel.Error.DbusError", 4549 "Subsystem": "cec_op_panel", 4550 "ComponentID": "0x5000", 4551 4552 "SRC": { 4553 "ReasonCode": "0x5004", 4554 "Words6To9": {} 4555 }, 4556 4557 "Callouts": [{ 4558 "CalloutList": [{ 4559 "Priority": "high", 4560 "Procedure": "bmc_code" 4561 }] 4562 }], 4563 4564 "Documentation": { 4565 "Description": "Dbus exception", 4566 "Message": "A Dbus internal error occurred.", 4567 "Notes": [ 4568 "This error occurs when Dbus operation fails.", 4569 "Exceptions details are captured in additional", 4570 "data." 4571 ] 4572 } 4573 }, 4574 4575 { 4576 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 4577 "Subsystem": "cec_sp_hostboot_iface", 4578 4579 "SRC": 4580 { 4581 "ReasonCode": "0xC101", 4582 "Words6To9": 4583 { 4584 } 4585 }, 4586 4587 "Documentation": 4588 { 4589 "Description": "Host did not respond within the watchdog timeout interval", 4590 "Message": "Host did not respond before the watchdog timeout interval expired", 4591 "Notes": [ 4592 "Host did not respond before the expiry of the watchdog timeout interval.", 4593 "Collecting hostboot dump." 4594 ] 4595 } 4596 }, 4597 4598 { 4599 "Name": "xyz.openbmc_project.Software.Version.Error.Incompatible", 4600 "Subsystem": "bmc_firmware", 4601 "ComponentID": "0x3600", 4602 "SRC": 4603 { 4604 "ReasonCode": "0x3601", 4605 "Words6To9": 4606 { 4607 } 4608 }, 4609 4610 "Callouts": [ 4611 { 4612 "CalloutList": [ 4613 { "Priority": "high", "Procedure": "bmc_code" } 4614 ] 4615 } 4616 ], 4617 4618 "Documentation": 4619 { 4620 "Description": "A system component has a software version that is incompatible.", 4621 "Message": "A system component has a software version that is incompatible." 4622 } 4623 }, 4624 4625 { 4626 "Name": "xyz.openbmc_project.Software.Version.Error.AlreadyExists", 4627 "Subsystem": "bmc_firmware", 4628 "ComponentID": "0x3600", 4629 "SRC": 4630 { 4631 "ReasonCode": "0x3602", 4632 "Words6To9": 4633 { 4634 } 4635 }, 4636 4637 "Callouts": [ 4638 { 4639 "CalloutList": [ 4640 { "Priority": "high", "Procedure": "bmc_code" } 4641 ] 4642 } 4643 ], 4644 4645 "Documentation": 4646 { 4647 "Description": "This image version already exists on the device.", 4648 "Message": "This image version already exists on the device." 4649 } 4650 }, 4651 4652 { 4653 "Name": "xyz.openbmc_project.Software.Image.Error.UnTarFailure", 4654 "Subsystem": "bmc_firmware", 4655 "ComponentID": "0x3600", 4656 "SRC": 4657 { 4658 "ReasonCode": "0x3603", 4659 "Words6To9": 4660 { 4661 } 4662 }, 4663 4664 "Callouts": [ 4665 { 4666 "CalloutList": [ 4667 { "Priority": "high", "Procedure": "bmc_code" } 4668 ] 4669 } 4670 ], 4671 4672 "Documentation": 4673 { 4674 "Description": "An error occurred during untar.", 4675 "Message": "An error occurred during untar." 4676 } 4677 }, 4678 4679 { 4680 "Name": "xyz.openbmc_project.Software.Image.Error.ManifestFileFailure", 4681 "Subsystem": "bmc_firmware", 4682 "ComponentID": "0x3600", 4683 "SRC": 4684 { 4685 "ReasonCode": "0x3604", 4686 "Words6To9": 4687 { 4688 } 4689 }, 4690 4691 "Callouts": [ 4692 { 4693 "CalloutList": [ 4694 { "Priority": "high", "Procedure": "bmc_code" } 4695 ] 4696 } 4697 ], 4698 4699 "Documentation": 4700 { 4701 "Description": "An error occurred when reading the software image Manifest file.", 4702 "Message": "An error occurred when reading the software image Manifest file." 4703 } 4704 }, 4705 4706 { 4707 "Name": "xyz.openbmc_project.Software.Image.Error.InternalFailure", 4708 "Subsystem": "bmc_firmware", 4709 "ComponentID": "0x3600", 4710 "SRC": 4711 { 4712 "ReasonCode": "0x3605", 4713 "Words6To9": 4714 { 4715 } 4716 }, 4717 4718 "Callouts": [ 4719 { 4720 "CalloutList": [ 4721 { "Priority": "high", "Procedure": "bmc_code" } 4722 ] 4723 } 4724 ], 4725 4726 "Documentation": 4727 { 4728 "Description": "The operation failed internally during processing the image.", 4729 "Message": "The operation failed internally during processing the image." 4730 } 4731 }, 4732 4733 { 4734 "Name": "xyz.openbmc_project.Software.Image.Error.ImageFailure", 4735 "Subsystem": "bmc_firmware", 4736 "ComponentID": "0x3600", 4737 "SRC": 4738 { 4739 "ReasonCode": "0x3606", 4740 "Words6To9": 4741 { 4742 } 4743 }, 4744 4745 "Callouts": [ 4746 { 4747 "CalloutList": [ 4748 { "Priority": "high", "Procedure": "bmc_code" } 4749 ] 4750 } 4751 ], 4752 4753 "Documentation": 4754 { 4755 "Description": "An error occurred processing the image.", 4756 "Message": "An error occurred processing the image." 4757 } 4758 }, 4759 4760 { 4761 "Name": "xyz.openbmc_project.Software.Image.Error.BusyFailure", 4762 "Subsystem": "bmc_firmware", 4763 "ComponentID": "0x3600", 4764 "SRC": 4765 { 4766 "ReasonCode": "0x3607", 4767 "Words6To9": 4768 { 4769 } 4770 }, 4771 4772 "Callouts": [ 4773 { 4774 "CalloutList": [ 4775 { "Priority": "high", "Procedure": "bmc_code" } 4776 ] 4777 } 4778 ], 4779 4780 "Documentation": 4781 { 4782 "Description": "The device is busy during the update.", 4783 "Message": "The device is busy during the update." 4784 } 4785 }, 4786 4787 { 4788 "Name": "xyz.openbmc_project.Software.Version.Error.ExpiredAccessKey", 4789 "Subsystem": "bmc_firmware", 4790 "ComponentID": "0x3600", 4791 "SRC": 4792 { 4793 "ReasonCode": "0x3608", 4794 "Words6To9": 4795 { 4796 } 4797 }, 4798 4799 "Callouts": [ 4800 { 4801 "CalloutList": [ 4802 { "Priority": "high", "Procedure": "bmc_code" } 4803 ] 4804 } 4805 ], 4806 4807 "Documentation": 4808 { 4809 "Description": "The Update Access Key has expired.", 4810 "Message": "The Update Access Key has expired." 4811 } 4812 }, 4813 4814 { 4815 "Name": "xyz.openbmc_project.Software.Version.Error.InvalidSignature", 4816 "Subsystem": "bmc_firmware", 4817 "ComponentID": "0x3600", 4818 "SRC": 4819 { 4820 "ReasonCode": "0x3609", 4821 "Words6To9": 4822 { 4823 } 4824 }, 4825 4826 "Callouts": [ 4827 { 4828 "CalloutList": [ 4829 { "Priority": "high", "Procedure": "bmc_code" } 4830 ] 4831 } 4832 ], 4833 4834 "Documentation": 4835 { 4836 "Description": "The software image has an invalid signature.", 4837 "Message": "The software image has an invalid signature" 4838 } 4839 }, 4840 4841 { 4842 "Name" : "xyz.openbmc_project.Software.Version.Error.HostFile", 4843 "Subsystem" : "bmc_firmware", 4844 "ComponentID" : "0x3600", 4845 4846 "SRC" : 4847 { 4848 "ReasonCode" : "0x360A", 4849 "Words6To9": 4850 { 4851 "6": 4852 { 4853 "Description" : "Size of the current running partition", 4854 "AdditionalDataPropSource" : "CURRENT_FILE_SIZE" 4855 }, 4856 "7": 4857 { 4858 "Description" : "Size of the read only partition", 4859 "AdditionalDataPropSource" : "EXPECTED_FILE_SIZE" 4860 } 4861 } 4862 }, 4863 "Callouts": [ 4864 { 4865 "CalloutList": [ 4866 { "Priority": "high", "Procedure": "bmc_code" } 4867 ] 4868 } 4869 ], 4870 "Documentation" : 4871 { 4872 "Description" : "Corrupted or changed preserved file", 4873 "Message" : "Partition was not preserved on reboot", 4874 "Notes" : [ 4875 "This error may occur if one of the partitions marked", 4876 "PRESERVED is either corrupted, or a change of size is ", 4877 "desired for a particular partition." 4878 ] 4879 } 4880 }, 4881 4882 { 4883 "Name": "xyz.openbmc_project.PLDM.Error.findDumpObjPath.GetManagedObjectsFail", 4884 "Subsystem": "bmc_firmware", 4885 "ComponentID": "0x6000", 4886 "Severity": "predictive", 4887 "SRC": 4888 { 4889 "ReasonCode": "0x6001", 4890 "Words6To9": 4891 { 4892 } 4893 }, 4894 "Callouts": [ 4895 { 4896 "CalloutList": [ 4897 { "Priority": "high", "Procedure": "bmc_code" } 4898 ] 4899 } 4900 ], 4901 4902 "Documentation": 4903 { 4904 "Description": "Failed to get the requested dump object path.", 4905 "Message": "Failed to get the requested dump object path from the system." 4906 } 4907 }, 4908 { 4909 "Name": "xyz.openbmc_project.PLDM.Error.newFileAvailable.NewDumpNotifyFail", 4910 "Subsystem": "bmc_firmware", 4911 "ComponentID": "0x6000", 4912 "Severity": "unrecoverable", 4913 "SRC": 4914 { 4915 "ReasonCode": "0x6002", 4916 "Words6To9": 4917 { 4918 } 4919 }, 4920 "Callouts": [ 4921 { 4922 "CalloutList": [ 4923 { "Priority": "high", "Procedure": "bmc_code" } 4924 ] 4925 } 4926 ], 4927 "Documentation": 4928 { 4929 "Description": "Failed to make a new dump notify request to the dump manager application.", 4930 "Message": "Failed to make a new dump notify request to the dump manager application." 4931 } 4932 }, 4933 { 4934 "Name": "xyz.openbmc_project.PLDM.Error.DumpHandler.getOffloadUriFail", 4935 "Subsystem": "bmc_firmware", 4936 "ComponentID": "0x6000", 4937 "Severity": "unrecoverable", 4938 "SRC": 4939 { 4940 "ReasonCode": "0x6003", 4941 "Words6To9": 4942 { 4943 } 4944 }, 4945 "Callouts": [ 4946 { 4947 "CalloutList": [ 4948 { "Priority": "high", "Procedure": "bmc_code" } 4949 ] 4950 } 4951 ], 4952 "Documentation": 4953 { 4954 "Description": "Failed to get the dump offload URI path from the dump entry.", 4955 "Message": "Failed to get the dump offload URI path from the dump entry." 4956 } 4957 }, 4958 { 4959 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.ResourceDumpFileAckFail", 4960 "Subsystem": "bmc_firmware", 4961 "ComponentID": "0x6000", 4962 "Severity": "non_error", 4963 "SRC": 4964 { 4965 "ReasonCode": "0x6004", 4966 "Words6To9": 4967 { 4968 } 4969 }, 4970 "Callouts": [ 4971 { 4972 "CalloutList": [ 4973 { "Priority": "medium", "Procedure": "bmc_code" } 4974 ] 4975 } 4976 ], 4977 "Documentation": 4978 { 4979 "Description": "The hypervisor rejected the request to initiate a new resource dump.", 4980 "Message": "The hypervisor rejected the request to initiate a new resource dump." 4981 } 4982 }, 4983 { 4984 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.SourceDumpIdResetFail", 4985 "Subsystem": "bmc_firmware", 4986 "ComponentID": "0x6000", 4987 "Severity": "unrecoverable", 4988 "SRC": 4989 { 4990 "ReasonCode": "0x6005", 4991 "Words6To9": 4992 { 4993 } 4994 }, 4995 "Callouts": [ 4996 { 4997 "CalloutList": [ 4998 { "Priority": "high", "Procedure": "bmc_code" } 4999 ] 5000 } 5001 ], 5002 "Documentation": 5003 { 5004 "Description": "Failed to reset the dump ID, due to this requested dump will not be deleted.", 5005 "Message": "Failed to reset the dump ID, due to this requested dump will not be deleted." 5006 } 5007 }, 5008 { 5009 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryDeleteFail", 5010 "Subsystem": "bmc_firmware", 5011 "ComponentID": "0x6000", 5012 "Severity": "unrecoverable", 5013 "SRC": 5014 { 5015 "ReasonCode": "0x6006", 5016 "Words6To9": 5017 { 5018 } 5019 }, 5020 "Callouts": [ 5021 { 5022 "CalloutList": [ 5023 { "Priority": "high", "Procedure": "bmc_code" } 5024 ] 5025 } 5026 ], 5027 "Documentation": 5028 { 5029 "Description": "Failed to carry out the dump delete request from the hypervisor.", 5030 "Message": "Failed to carry out the dump delete request from the hypervisor." 5031 } 5032 }, 5033 { 5034 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryOffloadedSetFail", 5035 "Subsystem": "bmc_firmware", 5036 "ComponentID": "0x6000", 5037 "Severity": "unrecoverable", 5038 "SRC": 5039 { 5040 "ReasonCode": "0x6007", 5041 "Words6To9": 5042 { 5043 } 5044 }, 5045 "Callouts": [ 5046 { 5047 "CalloutList": [ 5048 { "Priority": "high", "Procedure": "bmc_code" } 5049 ] 5050 } 5051 ], 5052 "Documentation": 5053 { 5054 "Description": "Failed to set the dump offloaded completion flag in the dump entry.", 5055 "Message": "Failed to set the dump offloaded completion flag in the dump entry." 5056 } 5057 }, 5058 { 5059 "Name": "xyz.openbmc_project.PLDM.Error.readIntoMemory.GetFilepathFail", 5060 "Subsystem": "bmc_firmware", 5061 "ComponentID": "0x6000", 5062 "Severity": "unrecoverable", 5063 "SRC": 5064 { 5065 "ReasonCode": "0x6008", 5066 "Words6To9": 5067 { 5068 } 5069 }, 5070 "Callouts": [ 5071 { 5072 "CalloutList": [ 5073 { "Priority": "high", "Procedure": "bmc_code" } 5074 ] 5075 } 5076 ], 5077 "Documentation": 5078 { 5079 "Description": "Failed to get the file path for the BMC dump and offload to the hypervisor.", 5080 "Message": "Failed to get the file path for the BMC dump and offload to the hypervisor." 5081 } 5082 }, 5083 { 5084 "Name": "xyz.openbmc_project.PLDM.Error.read.GetFilepathFail", 5085 "Subsystem": "bmc_firmware", 5086 "ComponentID": "0x6000", 5087 "Severity": "unrecoverable", 5088 "SRC": 5089 { 5090 "ReasonCode": "0x6009", 5091 "Words6To9": 5092 { 5093 } 5094 }, 5095 "Callouts": [ 5096 { 5097 "CalloutList": [ 5098 { "Priority": "high", "Procedure": "bmc_code" } 5099 ] 5100 } 5101 ], 5102 "Documentation": 5103 { 5104 "Description": "Failed to get the file path for the BMC dump and offload to the hypervisor.", 5105 "Message": "Failed to get the file path for the BMC dump and offload to the hypervisor." 5106 } 5107 }, 5108 { 5109 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.ResourceDumpFileAckWithMetaDataFail", 5110 "Subsystem": "bmc_firmware", 5111 "ComponentID": "0x6000", 5112 "Severity": "non_error", 5113 "SRC": 5114 { 5115 "ReasonCode": "0x6010", 5116 "Words6To9": 5117 { 5118 } 5119 }, 5120 "Callouts": [ 5121 { 5122 "CalloutList": [ 5123 { "Priority": "medium", "Procedure": "bmc_code" } 5124 ] 5125 } 5126 ], 5127 "Documentation": 5128 { 5129 "Description": "Could not create a new resource dump due to hypervisor verification failed.", 5130 "Message": "Could not create a new resource dump due to hypervisor verification failed." 5131 } 5132 }, 5133 { 5134 "Name": "xyz.openbmc_project.PLDM.Error.fileAckWithMetaData.DumpEntryOffloadedSetFail", 5135 "Subsystem": "bmc_firmware", 5136 "ComponentID": "0x6000", 5137 "Severity": "unrecoverable", 5138 "SRC": 5139 { 5140 "ReasonCode": "0x6011", 5141 "Words6To9": 5142 { 5143 } 5144 }, 5145 "Callouts": [ 5146 { 5147 "CalloutList": [ 5148 { "Priority": "high", "Procedure": "bmc_code" } 5149 ] 5150 } 5151 ], 5152 "Documentation": 5153 { 5154 "Description": "Failed to set the dump offload completion flag in the dump entry details.", 5155 "Message": "Failed to set the dump offload completion flag in the dump entry details." 5156 } 5157 }, 5158 { 5159 "Name": "xyz.openbmc_project.PLDM.Error.newFileAvailableWithMetaData.NewDumpNotifyFail", 5160 "Subsystem": "bmc_firmware", 5161 "ComponentID": "0x6000", 5162 "Severity": "unrecoverable", 5163 "SRC": 5164 { 5165 "ReasonCode": "0x6012", 5166 "Words6To9": 5167 { 5168 } 5169 }, 5170 "Callouts": [ 5171 { 5172 "CalloutList": [ 5173 { "Priority": "high", "Procedure": "bmc_code" } 5174 ] 5175 } 5176 ], 5177 "Documentation": 5178 { 5179 "Description": "Failed to notify a new dump available request.", 5180 "Message": "Failed to notify a new dump available request." 5181 } 5182 }, 5183 { 5184 "Name": "xyz.openbmc_project.PLDM.Error.sendNewFileAvailableCmd.SendDumpParametersFail", 5185 "Subsystem": "bmc_firmware", 5186 "ComponentID": "0x6000", 5187 "Severity": "unrecoverable", 5188 "SRC": 5189 { 5190 "ReasonCode": "0x6013", 5191 "Words6To9": 5192 { 5193 } 5194 }, 5195 "Callouts": [ 5196 { 5197 "CalloutList": [ 5198 { "Priority": "high", "Procedure": "bmc_code" } 5199 ] 5200 } 5201 ], 5202 "Documentation": 5203 { 5204 "Description": "Failed to send the resource dump parameters for a new dump initiation.", 5205 "Message": "Failed to send the resource dump parameters for a new dump initiation." 5206 } 5207 }, 5208 { 5209 "Name": "xyz.openbmc_project.PLDM.Error.SendFileToHostFail", 5210 "Subsystem": "bmc_firmware", 5211 "ComponentID": "0x6000", 5212 "Severity": "unrecoverable", 5213 "SRC": 5214 { 5215 "ReasonCode": "0x6014", 5216 "Words6To9": 5217 { 5218 } 5219 }, 5220 "Callouts": [ 5221 { 5222 "CalloutList": [ 5223 { "Priority": "high", "Procedure": "bmc_code" } 5224 ] 5225 } 5226 ], 5227 "Documentation": 5228 { 5229 "Description": "Failed to send the certificate/license file to the host.", 5230 "Message": "Failed to send the certificate/license file to the host." 5231 } 5232 }, 5233 { 5234 "Name": "xyz.openbmc_project.PLDM.Error.DecodeNewFileResponseFail", 5235 "Subsystem": "bmc_firmware", 5236 "ComponentID": "0x6000", 5237 "Severity": "unrecoverable", 5238 "SRC": 5239 { 5240 "ReasonCode": "0x6015", 5241 "Words6To9": 5242 { 5243 } 5244 }, 5245 "Callouts": [ 5246 { 5247 "CalloutList": [ 5248 { "Priority": "high", "Procedure": "bmc_code" } 5249 ] 5250 } 5251 ], 5252 "Documentation": 5253 { 5254 "Description": "Failed to decode the response of certificate/license file sent to the host.", 5255 "Message": "Failed to decode the response of certificate/license file sent to the host." 5256 } 5257 }, 5258 { 5259 "Name": "xyz.openbmc_project.PLDM.Error.NewFileAvailableRequestFail", 5260 "Subsystem": "bmc_firmware", 5261 "ComponentID": "0x6000", 5262 "Severity": "unrecoverable", 5263 "SRC": 5264 { 5265 "ReasonCode": "0x6016", 5266 "Words6To9": 5267 { 5268 } 5269 }, 5270 "Callouts": [ 5271 { 5272 "CalloutList": [ 5273 { "Priority": "high", "Procedure": "bmc_code" } 5274 ] 5275 } 5276 ], 5277 "Documentation": 5278 { 5279 "Description": "Failed to send the new certificate/license file to the host.", 5280 "Message": "Failed to send the new certificate/license file to the host." 5281 } 5282 }, 5283 { 5284 "Name": "xyz.openbmc_project.PLDM.Error.SetHostEffecterFailed", 5285 "Subsystem": "bmc_firmware", 5286 "ComponentID": "0x6000", 5287 "Severity": "unrecoverable", 5288 "SRC": 5289 { 5290 "ReasonCode": "0x6017", 5291 "Words6To9": 5292 { 5293 } 5294 }, 5295 5296 "Callouts": [ 5297 { 5298 "CalloutList": [ 5299 { "Priority": "high", "Procedure": "bmc_code" } 5300 ] 5301 } 5302 ], 5303 "Documentation": 5304 { 5305 "Description": "Failed to set state effecter states.", 5306 "Message": "Failed to set state effecter states." 5307 } 5308 }, 5309 { 5310 "Name": "xyz.openbmc_project.PLDM.Error.Generate.PDRJsonFileParseFail", 5311 "Subsystem": "bmc_firmware", 5312 "ComponentID": "0x6000", 5313 "Severity": "unrecoverable", 5314 "SRC": 5315 { 5316 "ReasonCode": "0x6018", 5317 "Words6To9": 5318 { 5319 } 5320 }, 5321 "Callouts": [ 5322 { 5323 "CalloutList": [ 5324 { "Priority": "high", "Procedure": "bmc_code" } 5325 ] 5326 } 5327 ], 5328 "Documentation": 5329 { 5330 "Description": "Failed to parse PDR JSON file.", 5331 "Message": "Failed to parse PDR JSON file." 5332 } 5333 }, 5334 { 5335 "Name": "xyz.openbmc_project.PLDM.Error.SetHostSensorState.GetStateSensorPDRFail", 5336 "Subsystem": "bmc_firmware", 5337 "ComponentID": "0x6000", 5338 "Severity": "unrecoverable", 5339 "SRC": 5340 { 5341 "ReasonCode": "0x6019", 5342 "Words6To9": 5343 { 5344 } 5345 }, 5346 "Callouts": [ 5347 { 5348 "CalloutList": [ 5349 { "Priority": "high", "Procedure": "bmc_code" } 5350 ] 5351 } 5352 ], 5353 "Documentation": 5354 { 5355 "Description": "Failed to get state sensor PDR state.", 5356 "Message": "Failed to get state sensor PDR state." 5357 } 5358 }, 5359 { 5360 "Name": "xyz.openbmc_project.PLDM.Error.SetHostSensorState.EncodeStateSensorFail", 5361 "Subsystem": "bmc_firmware", 5362 "ComponentID": "0x6000", 5363 "Severity": "unrecoverable", 5364 "SRC": 5365 { 5366 "ReasonCode": "0x6020", 5367 "Words6To9": 5368 { 5369 } 5370 }, 5371 "Callouts": [ 5372 { 5373 "CalloutList": [ 5374 { "Priority": "high", "Procedure": "bmc_code" } 5375 ] 5376 } 5377 ], 5378 "Documentation": 5379 { 5380 "Description": "Failed to encode state sensor request.", 5381 "Message": "Failed to encode state sensor request." 5382 } 5383 }, 5384 { 5385 "Name": "xyz.openbmc_project.PLDM.Error.CMsubscribeFailure", 5386 "Subsystem": "bmc_firmware", 5387 "ComponentID": "0x6000", 5388 "Severity": "unrecoverable", 5389 "SRC": 5390 { 5391 "ReasonCode": "0x6021", 5392 "Words6To9": 5393 { 5394 } 5395 }, 5396 "Callouts": [ 5397 { 5398 "CalloutList": [ 5399 { "Priority": "high", "Procedure": "bmc_code" } 5400 ] 5401 } 5402 ], 5403 "Documentation": 5404 { 5405 "Description": "Failed to subscribe for concurrent maintenance of FRU.", 5406 "Message": "Failed to subscribe for concurrent maintenance of FRU." 5407 } 5408 }, 5409 { 5410 "Name": "xyz.openbmc_project.PLDM.Error.setSurvTimer.RecvSurveillancePingFail", 5411 "Subsystem": "bmc_firmware", 5412 "ComponentID": "0x6000", 5413 "Severity": "non_error", 5414 "SRC": 5415 { 5416 "ReasonCode": "0x6022", 5417 "Words6To9": 5418 { 5419 } 5420 }, 5421 "Callouts": [ 5422 { 5423 "CalloutList": [ 5424 { "Priority": "high", "Procedure": "bmc_code" } 5425 ] 5426 } 5427 ], 5428 "Documentation": 5429 { 5430 "Description": "Host did not send a surveillance ping within stipulated timeout interval.", 5431 "Message": "Host did not send a surveillance ping within stipulated timeout interval." 5432 } 5433 }, 5434 { 5435 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryOffloadUriSetFail", 5436 "Subsystem": "bmc_firmware", 5437 "ComponentID": "0x6000", 5438 "Severity": "unrecoverable", 5439 "SRC": 5440 { 5441 "ReasonCode": "0x6023", 5442 "Words6To9": 5443 { 5444 } 5445 }, 5446 "Callouts": [ 5447 { 5448 "CalloutList": [ 5449 { "Priority": "high", "Procedure": "bmc_code" } 5450 ] 5451 } 5452 ], 5453 "Documentation": 5454 { 5455 "Description": "Failed to reset the dump offload URI path from the dump entry.", 5456 "Message": "Failed to reset the dump offload URI path from the dump entry." 5457 } 5458 }, 5459 { 5460 "Name": "xyz.openbmc_project.PLDM.Error.SoftPowerOff.HostSoftOffTimeOut", 5461 "Subsystem": "bmc_firmware", 5462 "ComponentID": "0x6000", 5463 "Severity": "unrecoverable", 5464 "SRC": 5465 { 5466 "ReasonCode": "0x6024", 5467 "Words6To9": 5468 { 5469 } 5470 }, 5471 "Callouts": [ 5472 { 5473 "CalloutList": [ 5474 { "Priority": "high", "Procedure": "bmc_code" } 5475 ] 5476 } 5477 ], 5478 "Documentation": 5479 { 5480 "Description": "Host failed to complete the power off gracefully within the timeout.", 5481 "Message": "Host failed to complete the power off gracefully within the timeout." 5482 } 5483 } 5484 ] 5485} 5486