1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 "Severity": "non_error", 8 9 "SRC": 10 { 11 "ReasonCode": "0x1001", 12 "Words6To9": 13 { 14 "6": 15 { 16 "Description": "Timeout in ms", 17 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 18 } 19 } 20 }, 21 22 "Documentation": 23 { 24 "Description": "This is a generic timeout error", 25 "Message": "An operation timed out", 26 "Notes": [ 27 "The journal should contain more information" 28 ] 29 } 30 }, 31 32 { 33 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 34 "Subsystem": "bmc_firmware", 35 "Severity": "non_error", 36 37 "SRC": 38 { 39 "ReasonCode": "0x1002", 40 "Words6To9": 41 { 42 } 43 }, 44 45 "Documentation": 46 { 47 "Description": "BMC code had a generic internal failure", 48 "Message": "An application had an internal failure", 49 "Notes": [ 50 "The journal should contain more information" 51 ] 52 } 53 }, 54 55 { 56 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 57 "Subsystem": "user_error", 58 "Severity": "non_error", 59 60 "SRC": 61 { 62 "ReasonCode": "0x1003", 63 "Words6To9": 64 { 65 } 66 }, 67 68 "Documentation": 69 { 70 "Description": "BMC code was given an invalid argument", 71 "Message": "Code was given an invalid argument", 72 "Notes": [ 73 "The journal should contain more information" 74 ] 75 } 76 }, 77 { 78 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 79 "Subsystem": "user_error", 80 "Severity": "non_error", 81 82 "SRC": 83 { 84 "ReasonCode": "0x1004", 85 "Words6To9": 86 { 87 } 88 }, 89 90 "Documentation": 91 { 92 "Description": "An operation failed due to insufficient permission", 93 "Message": "An operation failed due to unsufficient permission", 94 "Notes": [ 95 "The journal should contain more information" 96 ] 97 } 98 }, 99 100 { 101 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 102 "Subsystem": "user_error", 103 "Severity": "non_error", 104 105 "SRC": 106 { 107 "ReasonCode": "0x1005", 108 "Words6To9": 109 { 110 } 111 }, 112 113 "Documentation": 114 { 115 "Description": "An operation failed because it isn't allowed", 116 "Message": "An operation failed because it isn't allowed", 117 "Notes": [ 118 "The journal should contain more information" 119 ] 120 } 121 }, 122 123 { 124 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 125 "Subsystem": "user_error", 126 "Severity": "non_error", 127 128 "SRC": 129 { 130 "ReasonCode": "0x1006", 131 "Words6To9": 132 { 133 } 134 }, 135 136 "Documentation": 137 { 138 "Description": "The server's CA certificate has not been provided", 139 "Message": "The server's CA certificate has not been provided" 140 } 141 }, 142 143 { 144 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 145 "Subsystem": "cec_i2c", 146 147 "SRC": 148 { 149 "ReasonCode": "0x1007", 150 "Words6To9": 151 { 152 "6": 153 { 154 "Description": "errno of the failure", 155 "AdditionalDataPropSource": "CALLOUT_ERRNO" 156 } 157 } 158 }, 159 160 "Documentation": 161 { 162 "Description": "Sensor device read failure", 163 "Message": "There was a failure when reading a sensor device", 164 "Notes": [ 165 "The severity is set by the creator.", 166 "The action flags are set automatically by the code.", 167 "Callouts added based on CALLOUT_DEVICE_PATH." 168 ] 169 } 170 }, 171 172 { 173 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 174 "Subsystem": "cec_i2c", 175 176 "SRC": 177 { 178 "ReasonCode": "0x1008", 179 "Words6To9": 180 { 181 "6": 182 { 183 "Description": "errno of the failure", 184 "AdditionalDataPropSource": "CALLOUT_ERRNO" 185 } 186 } 187 }, 188 189 "Documentation": 190 { 191 "Description": "Device read failure", 192 "Message": "There was a failure when reading a hardware device", 193 "Notes": [ 194 "The severity is set by the creator.", 195 "The action flags are set automatically by the code.", 196 "Callouts added based on CALLOUT_DEVICE_PATH." 197 ] 198 } 199 }, 200 201 { 202 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 203 "Subsystem": "cec_i2c", 204 205 "SRC": 206 { 207 "ReasonCode": "0x1009", 208 "Words6To9": 209 { 210 "6": 211 { 212 "Description": "errno of the failure", 213 "AdditionalDataPropSource": "CALLOUT_ERRNO" 214 } 215 } 216 }, 217 218 "Documentation": 219 { 220 "Description": "Device write failure", 221 "Message": "There was a failure when writing to a hardware device", 222 "Notes": [ 223 "The severity is set by the creator.", 224 "The action flags are set automatically by the code.", 225 "Callouts added based on CALLOUT_DEVICE_PATH" 226 ] 227 } 228 }, 229 230 { 231 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 232 "Subsystem": "cec_i2c", 233 234 "SRC": 235 { 236 "ReasonCode": "0x100A", 237 "Words6To9": 238 { 239 "6": 240 { 241 "Description": "errno of the failure", 242 "AdditionalDataPropSource": "CALLOUT_ERRNO" 243 } 244 } 245 }, 246 247 "Documentation": 248 { 249 "Description": "Device write failure", 250 "Message": "There was a failure when writing to a hardware device", 251 "Notes": [ 252 "The severity is set by the creator.", 253 "The action flags are set automatically by the code.", 254 "Callouts added based on CALLOUT_DEVICE_PATH" 255 ] 256 } 257 }, 258 259 { 260 "Name": "xyz.openbmc_project.Common.File.Error.Write", 261 "Subsystem": "bmc_firmware", 262 "ComponentID": "0x1000", 263 "SRC": 264 { 265 "ReasonCode": "0x100B", 266 "Words6To9": 267 { 268 } 269 }, 270 271 "Callouts": [ 272 { 273 "CalloutList": [ 274 { "Priority": "high", "Procedure": "bmc_code" } 275 ] 276 } 277 ], 278 279 "Documentation": 280 { 281 "Description": "Failed to write to a file", 282 "Message": "Failed to write to a file", 283 "Notes": [ 284 "The severity is set by the creator.", 285 "The journal should contain more information" 286 ] 287 } 288 }, 289 290 { 291 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 292 "Subsystem": "bmc_firmware", 293 "Severity": "non_error", 294 295 "SRC": 296 { 297 "ReasonCode": "0x2001", 298 "Words6To9": 299 { 300 "6": 301 { 302 "Description": "The bad PEL ID", 303 "AdditionalDataPropSource": "BAD_ID" 304 } 305 } 306 }, 307 308 "Documentation": 309 { 310 "Description": "The BMC sent the host a malformed PEL", 311 "Message": "The BMC sent the host a malformed PEL", 312 "Notes": [ 313 "The host firmware rejected that PEL." 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.BadHostPEL", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2002", 326 "Words6To9": 327 { 328 "6": 329 { 330 "Description": "The PLID of the invalid PEL", 331 "AdditionalDataPropSource": "PLID" 332 }, 333 "7": 334 { 335 "Description": "The corresponding OpenBMC event log ID", 336 "AdditionalDataPropSource": "OBMC_LOG_ID" 337 }, 338 "8": 339 { 340 "Description": "The size of the invalid PEL", 341 "AdditionalDataPropSource": "PEL_SIZE" 342 } 343 } 344 }, 345 346 "Callouts": [ 347 { 348 "CalloutList": [ 349 { "Priority": "high", "Procedure": "bmc_code" } 350 ] 351 } 352 ], 353 354 "Documentation": 355 { 356 "Description": "The host sent the BMC an invalid PEL", 357 "Message": "The host sent the BMC an invalid PEL", 358 "Notes": [ 359 ] 360 } 361 }, 362 363 { 364 "Name": "org.open_power.Logging.Error.TestError1", 365 "Subsystem": "platform_firmware", 366 "Severity": "unrecoverable", 367 368 "SRC": 369 { 370 "ReasonCode": "0x2003", 371 "Words6To9": 372 { 373 } 374 }, 375 376 "Callouts": [ 377 { 378 "CalloutList": [ 379 {"Priority": "high", "Procedure": "bmc_code"}, 380 {"Priority": "medium", "SymbolicFRU": "service_docs"} 381 ] 382 } 383 ], 384 385 "Documentation": 386 { 387 "Description": "An error for testing", 388 "Message": "This is a test error" 389 } 390 }, 391 392 { 393 "Name": "xyz.openbmc_project.Logging.Error.Default", 394 "Subsystem": "other_na", 395 396 "SRC": 397 { 398 "ReasonCode": "0x2004", 399 "Words6To9": 400 { 401 } 402 }, 403 404 "Callouts": [ 405 { 406 "CalloutList": [ 407 { "Priority": "high", "Procedure": "bmc_code" } 408 ] 409 } 410 ], 411 412 "Documentation": 413 { 414 "Description": "This entry is used when no other matching entry is found", 415 "Message": "Unknown (Original event not in message registry)", 416 "Notes": [ 417 "This is used when the actual error name isn't found in ", 418 "the registry. The original error name will be stored ", 419 "in the UserData section that contains the AdditionalData ", 420 "properties using the key ERROR_NAME.", 421 "This error may contain callouts if the creator passed ", 422 "them in.", 423 "The severity is set by the creator.", 424 "If this error is seen, then a code change needs to be ", 425 "made to add the missing error entry to this registry." 426 ] 427 } 428 }, 429 430 { 431 "Name": "org.open_power.Logging.Error.TestError2", 432 "Subsystem": "bmc_firmware", 433 "Severity": "recovered", 434 "ActionFlags": ["report"], 435 436 "SRC": 437 { 438 "ReasonCode": "0x2005", 439 "Words6To9": 440 { 441 } 442 }, 443 444 "Callouts": [ 445 { 446 "CalloutList": [ 447 { "Priority": "high", "LocCode": "P0" } 448 ] 449 } 450 ], 451 452 "Documentation": 453 { 454 "Description": "An error for testing", 455 "Message": "This is a test recoverable error", 456 "Notes": [ 457 "This error is not created by BMC code and is ", 458 "only used for error injection tests." 459 ] 460 } 461 }, 462 463 { 464 "Name": "org.open_power.PHAL.Error.Boot", 465 "Subsystem": "cec_hardware", 466 "ComponentID": "0x3000", 467 468 "SRC": 469 { 470 "ReasonCode": "0x3001", 471 "Words6To9": 472 { 473 } 474 }, 475 476 "Documentation": 477 { 478 "Description": "Failure occurred during boot process", 479 "Message": "Failure occurred during boot process", 480 "Notes": [ 481 "Debug traces will be captured in AdditionalData section" 482 ] 483 } 484 }, 485 486 { 487 "Name": "org.open_power.PHAL.Error.PrePowerOff", 488 "Subsystem": "cec_hardware", 489 "ComponentID": "0x3000", 490 491 "SRC": 492 { 493 "ReasonCode": "0x3002", 494 "Words6To9": 495 { 496 } 497 }, 498 499 "Documentation": 500 { 501 "Description": "Failure occurred during PHAL pre-poweroff operations", 502 "Message": "Failure occurred during PHAL pre-poweroff operations", 503 "Notes": [ 504 "Severity needs to be set based on needs for this registry.", 505 "FFDC (First Failure Data Collection) will be collected ", 506 "and added into PEL." 507 ] 508 } 509 }, 510 511 { 512 "Name": "org.open_power.PHAL.Error.devtreeSync", 513 "Subsystem": "cec_hardware", 514 "ComponentID": "0x3000", 515 "Severity": "unrecoverable", 516 517 "SRC": 518 { 519 "ReasonCode": "0x3003", 520 "Words6To9": 521 { 522 } 523 }, 524 525 "Documentation": 526 { 527 "Description": "Failure occurred during PHAL devtree sync ", 528 "Message": "Failure occurred during PHAL devtree sync", 529 "Notes": [ 530 "The journal should contain more information" 531 ] 532 } 533 }, 534 535 { 536 "Name": "org.open_power.PHAL.Error.devtreeBackup", 537 "Subsystem": "cec_hardware", 538 "ComponentID": "0x3000", 539 "Severity": "unrecoverable", 540 541 "SRC": 542 { 543 "ReasonCode": "0x3004", 544 "Words6To9": 545 { 546 } 547 }, 548 549 "Documentation": 550 { 551 "Description": "Failure occurred during PHAL devtree backup ", 552 "Message": "Failure occurred during PHAL devtree backup", 553 "Notes": [ 554 "The journal should contain more information" 555 ] 556 } 557 }, 558 559 { 560 "Name": "org.open_power.PHAL.Error.HostRunning", 561 "Subsystem": "cec_sp_hyp_iface", 562 "ComponentID": "0x3000", 563 564 "SRC": 565 { 566 "ReasonCode": "0x3005", 567 "Words6To9": 568 { 569 } 570 }, 571 572 "Documentation": 573 { 574 "Description": "Host did not respond to BMC after a BMC reset", 575 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 576 "Notes": [ 577 "System will be left in its current state to ensure host ", 578 "is not unexpectedly taken down. There is most likely an ", 579 "issue in the software or hardware communication path ", 580 "between the BMC and the Host firmware.", 581 "A BMC dump will be collected with relevant FFDC." 582 ] 583 } 584 }, 585 586 { 587 "Name": "org.open_power.PHAL.Error.devtreeReinit", 588 "Subsystem": "cec_hardware", 589 "ComponentID": "0x3000", 590 "Severity": "unrecoverable", 591 592 "SRC": 593 { 594 "ReasonCode": "0x3006", 595 "Words6To9": 596 { 597 } 598 }, 599 600 "Documentation": 601 { 602 "Description": "Failure re-initializing BMC to Host data structure", 603 "Message": "Failure occurred during re-initializing BMC to Host data structure", 604 "Notes": [ 605 "The journal should contain more information" 606 ] 607 } 608 }, 609 610 { 611 "Name": "org.open_power.PHAL.Error.NonFunctionalBootProc", 612 "Subsystem": "cec_hardware", 613 "ComponentID": "0x3000", 614 "Severity": "unrecoverable", 615 616 "SRC": 617 { 618 "ReasonCode": "0x3007", 619 "Words6To9": 620 { 621 } 622 }, 623 624 "Documentation": 625 { 626 "Description": "Non functional boot processor", 627 "Message": "Non functional boot processor", 628 "Notes": [ 629 "BMC firmware couldn't find functional primary processor", 630 "required to boot the host", 631 "Debug traces will be captured in AdditionalData section" 632 ] 633 } 634 }, 635 636 { 637 "Name": "org.open_power.PHAL.Error.MPReboot", 638 "Subsystem": "cec_hardware", 639 "ComponentID": "0x3000", 640 "Severity": "unrecoverable", 641 642 "SRC": 643 { 644 "ReasonCode": "0x3008", 645 "Words6To9": 646 { 647 } 648 }, 649 650 "Callouts": [ 651 { 652 "CalloutList": [{"Priority": "high", "Procedure": "bmc_code" } 653 ] 654 } 655 ], 656 657 "Documentation": 658 { 659 "Description": "Error during memory preserving reboot", 660 "Message": "Error during memory preserving reboot", 661 "Notes": [ 662 "Software error occured during memory preserving reboot" 663 ] 664 } 665 } 666, 667 { 668 "Name": "org.open_power.PHAL.Error.SpareClock", 669 "Subsystem": "cec_hardware", 670 "ComponentID": "0x3000", 671 "Severity": "non_error", 672 "ActionFlags": [ "service_action", "report", "call_home" ], 673 674 "SRC": 675 { 676 "ReasonCode": "0x3009", 677 "Words6To9": 678 { 679 } 680 }, 681 682 "Documentation": 683 { 684 "Description": "Error during Spare clock initialisation", 685 "Message": "Error during Spare clock initialisation", 686 "Notes": [ 687 "The CalloutList should use the clock symbolic FRU with position details." 688 ] 689 } 690 }, 691 692 { 693 "Name": "org.open_power.OCC.Firmware.PresenceMismatch", 694 "Subsystem": "bmc_firmware", 695 "ComponentID": "0x2600", 696 "Severity": "predictive", 697 698 "SRC": 699 { 700 "ReasonCode": "0x2681", 701 "Words6To9": 702 { 703 } 704 }, 705 706 "Callouts": [ 707 { 708 "CalloutList": [ 709 { "Priority": "medium", "Procedure": "bmc_code" } 710 ] 711 } 712 ], 713 714 "Documentation": 715 { 716 "Description": "OCC presence mismatch", 717 "Message": "BMC firmware detected incorrect number of OCCs", 718 "Notes": [ 719 "The number of OCCs detected by the BMC does not match the number of OCCs detected by the OCC.", 720 "The BMC requests that the OCC reset." 721 ] 722 } 723 }, 724 725 { 726 "Name": "org.open_power.OCC.Device.SafeState", 727 "Subsystem": "processor_chip", 728 "ComponentID": "0x2600", 729 "Severity": "non_error", 730 731 "SRC": 732 { 733 "ReasonCode": "0x2682", 734 "Words6To9": 735 { 736 } 737 }, 738 739 "Documentation": 740 { 741 "Description": "OCC safe state", 742 "Message": "OCC in safe state while active for one minute", 743 "Notes": [ 744 "The BMC detected that the OCC was in safe state for one minute while active.", 745 "The BMC requests that the OCC reset." 746 ] 747 } 748 }, 749 750 { 751 "Name": "org.open_power.OCC.Device.ReadFailure", 752 "Subsystem": "cec_chip_iface", 753 "ComponentID": "0x2600", 754 "Severity": "predictive", 755 756 "SRC": 757 { 758 "ReasonCode": "0x2683", 759 "Words6To9": 760 { 761 } 762 }, 763 764 "Documentation": 765 { 766 "Description": "OCC communication failure", 767 "Message": "BMC failed to communicate with the OCC", 768 "Notes": [ 769 "The BMC failed to communicate with the OCC and retried three times.", 770 "The BMC requests that the OCC reset." 771 ] 772 } 773 }, 774 775 { 776 "Name": "org.open_power.HardwareIsolation.Error", 777 "Subsystem": "cec_hardware", 778 "ComponentID": "0x3100", 779 780 "SRC": 781 { 782 "ReasonCode": "0x3101", 783 "Words6To9": 784 { 785 } 786 }, 787 788 "Documentation": 789 { 790 "Description": "Failure occurred during hardware isolation operations", 791 "Message": "Failure occurred during hardware isolation operations", 792 "Notes": [ 793 "Severity needs to be set based on needs for this registry.", 794 "Debug traces will be captured in AdditionalData section" 795 ] 796 } 797 }, 798 799 { 800 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 801 "Subsystem": "cec_sp_hostboot_iface", 802 "ComponentID": "0x3400", 803 "SRC": 804 { 805 "ReasonCode": "0x3401", 806 "Words6To9": 807 { 808 } 809 }, 810 "Documentation": 811 { 812 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 813 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 814 "Notes": [ 815 "System will follow recovery policy, resulting in this ", 816 "error and most likely a a reboot of the host. The issue ", 817 "is most likely the result of the BMC rebooting while the ", 818 "host was booting and in a state where it still needed ", 819 "the BMC to complete its boot." 820 ] 821 } 822 }, 823 824 { 825 "Name": "xyz.openbmc_project.State.ChassisPowerBad", 826 "Subsystem": "input_power_source", 827 "ComponentID": "0x3400", 828 "SRC": 829 { 830 "ReasonCode": "0x3402", 831 "Words6To9": 832 { 833 } 834 }, 835 "Callouts": [ 836 { 837 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 838 } 839 ], 840 "Documentation": 841 { 842 "Description": "Chassis input power is in a bad state", 843 "Message": "Chassis input power is in a bad state, look for other logs with more details", 844 "Notes": [ 845 "The system is most likely in a limited power situation. ", 846 "There is enough power for the BMC to operate but not the ", 847 "CEC hardware. Check for UPS or brownout logs." 848 ] 849 } 850 }, 851 852 { 853 "Name": "xyz.openbmc_project.State.PinholeReset", 854 "Subsystem": "cec_op_panel", 855 "ComponentID": "0x3400", 856 "SRC": 857 { 858 "ReasonCode": "0x3403", 859 "Words6To9": 860 { 861 } 862 }, 863 "Documentation": 864 { 865 "Description": "User initiated a pinhole reset via the op-panel", 866 "Message": "User initiated a pinhole reset via the op-panel", 867 "Notes": [ 868 "This is a notification log to record the fact that a ", 869 "pinhole reset was performed on the BMC, resulting in a ", 870 "hard reset of the BMC." 871 ] 872 } 873 }, 874 875 { 876 "Name": "xyz.openbmc_project.State.Error.CriticalServiceFailure", 877 "Subsystem": "bmc_firmware", 878 "ComponentID": "0x3400", 879 "SRC": 880 { 881 "ReasonCode": "0x3404", 882 "Words6To9": 883 { 884 } 885 }, 886 "Callouts": [ 887 { 888 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 889 } 890 ], 891 "Documentation": 892 { 893 "Description": "A critical BMC application has failed on the system", 894 "Message": "A critical BMC application has failed on the system, the BMC is in an undefined state", 895 "Notes": [ 896 "As a part of generating this error log, a BMC dump has ", 897 "also been generated. Please collect this dump if possible. ", 898 "The BMC state is undefined but basic services could still ", 899 "be available. Usually an AC cycle of the entire system is ", 900 "the best recovery option from this error." 901 ] 902 } 903 }, 904 905 { 906 "Name": "xyz.openbmc_project.State.Error.SecurityCheckFail", 907 "Subsystem": "bmc_firmware", 908 "ComponentID": "0x3400", 909 "SRC": 910 { 911 "ReasonCode": "0x3405", 912 "Words6To9": 913 { 914 } 915 }, 916 "Callouts": [ 917 { 918 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 919 } 920 ], 921 "Documentation": 922 { 923 "Description": "A firmware security check has failed", 924 "Message": "A firmware security check has failed, most likely something is not configured correctly", 925 "Notes": [ 926 "This log is only generated in the manufacturing ", 927 "environment and it indicates that something has not ", 928 "been configured correctly. Use the data in the PEL to ", 929 "determine what that is." 930 ] 931 } 932 }, 933 934 { 935 "Name": "xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure", 936 "Subsystem": "bmc_firmware", 937 "ComponentID": "0x3400", 938 "SRC": 939 { 940 "ReasonCode": "0x3406", 941 "Words6To9": 942 { 943 } 944 }, 945 "Callouts": [ 946 { 947 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 948 } 949 ], 950 "Documentation": 951 { 952 "Description": "The system has failed to reach BMC Ready state", 953 "Message": "The system has failed to reach BMC Ready state, look for other errors", 954 "Notes": [ 955 "This log indicates a critical BMC application required ", 956 "for the BMC to reach Ready state has failed to start ", 957 "successfully. Look in the log for other errors indicating ", 958 "what has failed." 959 ] 960 } 961 }, 962 963 { 964 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOnFailure", 965 "Subsystem": "bmc_firmware", 966 "ComponentID": "0x3400", 967 "SRC": 968 { 969 "ReasonCode": "0x3407", 970 "Words6To9": 971 { 972 } 973 }, 974 "Callouts": [ 975 { 976 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 977 } 978 ], 979 "Documentation": 980 { 981 "Description": "The system has failed to reach chassis power on state", 982 "Message": "The system has failed to reach chassis power on state, look for other errors", 983 "Notes": [ 984 "This log indicates a critical BMC application required ", 985 "for the BMC to power on the chassis has failed to start ", 986 "successfully. Look in the log for other errors indicating ", 987 "what has failed." 988 ] 989 } 990 }, 991 992 { 993 "Name": "xyz.openbmc_project.State.Chassis.Error.PowerOffFailure", 994 "Subsystem": "bmc_firmware", 995 "ComponentID": "0x3400", 996 "SRC": 997 { 998 "ReasonCode": "0x3408", 999 "Words6To9": 1000 { 1001 } 1002 }, 1003 "Callouts": [ 1004 { 1005 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1006 } 1007 ], 1008 "Documentation": 1009 { 1010 "Description": "The system has failed to reach chassis power off state", 1011 "Message": "The system has failed to reach chassis power off state, look for other errors", 1012 "Notes": [ 1013 "This log indicates a critical BMC application required ", 1014 "for the BMC to power off the chassis has failed to start ", 1015 "successfully. Look in the log for other errors indicating ", 1016 "what has failed." 1017 ] 1018 } 1019 }, 1020 1021 { 1022 "Name": "xyz.openbmc_project.State.Host.Error.HostStartFailure", 1023 "Subsystem": "bmc_firmware", 1024 "ComponentID": "0x3400", 1025 "SRC": 1026 { 1027 "ReasonCode": "0x3409", 1028 "Words6To9": 1029 { 1030 } 1031 }, 1032 "Callouts": [ 1033 { 1034 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1035 } 1036 ], 1037 "Documentation": 1038 { 1039 "Description": "The system has failed to start the host firmware", 1040 "Message": "The system has failed to start the host firmware, look for other errors", 1041 "Notes": [ 1042 "This log indicates a critical BMC application required ", 1043 "for the BMC to start the host has failed to start ", 1044 "successfully. Look in the log for other errors indicating ", 1045 "what has failed." 1046 ] 1047 } 1048 }, 1049 1050 { 1051 "Name": "xyz.openbmc_project.State.Host.Error.HostStartMinFailure", 1052 "Subsystem": "bmc_firmware", 1053 "ComponentID": "0x3400", 1054 "SRC": 1055 { 1056 "ReasonCode": "0x3410", 1057 "Words6To9": 1058 { 1059 } 1060 }, 1061 "Callouts": [ 1062 { 1063 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1064 } 1065 ], 1066 "Documentation": 1067 { 1068 "Description": "The system has failed to start the host firmware", 1069 "Message": "The system has failed to start the host firmware, look for other errors", 1070 "Notes": [ 1071 "This log indicates a critical BMC application required ", 1072 "for the BMC to start the host has failed to start ", 1073 "successfully. Look in the log for other errors indicating ", 1074 "what has failed." 1075 ] 1076 } 1077 }, 1078 1079 { 1080 "Name": "xyz.openbmc_project.State.Host.Error.HostShutdownFailure", 1081 "Subsystem": "bmc_firmware", 1082 "ComponentID": "0x3400", 1083 "SRC": 1084 { 1085 "ReasonCode": "0x3411", 1086 "Words6To9": 1087 { 1088 } 1089 }, 1090 "Callouts": [ 1091 { 1092 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1093 } 1094 ], 1095 "Documentation": 1096 { 1097 "Description": "The system has failed to shutdown the host firmware", 1098 "Message": "The system has failed to shutdown the host firmware, look for other errors", 1099 "Notes": [ 1100 "This log indicates a critical BMC application required ", 1101 "to shutdown the host firmware has failed to start ", 1102 "successfully. Look in the log for other errors indicating ", 1103 "what has failed." 1104 ] 1105 } 1106 }, 1107 1108 { 1109 "Name": "xyz.openbmc_project.State.Host.Error.HostStopFailure", 1110 "Subsystem": "bmc_firmware", 1111 "ComponentID": "0x3400", 1112 "SRC": 1113 { 1114 "ReasonCode": "0x3412", 1115 "Words6To9": 1116 { 1117 } 1118 }, 1119 "Callouts": [ 1120 { 1121 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1122 } 1123 ], 1124 "Documentation": 1125 { 1126 "Description": "The system has failed to stop the host firmware", 1127 "Message": "The system has failed to stop the host firmware, look for other errors", 1128 "Notes": [ 1129 "This log indicates a critical BMC application required ", 1130 "to stop the host firmware has failed to start ", 1131 "successfully. Look in the log for other errors indicating ", 1132 "what has failed." 1133 ] 1134 } 1135 }, 1136 1137 { 1138 "Name": "xyz.openbmc_project.State.Host.Error.HostRebootFailure", 1139 "Subsystem": "bmc_firmware", 1140 "ComponentID": "0x3400", 1141 "SRC": 1142 { 1143 "ReasonCode": "0x3413", 1144 "Words6To9": 1145 { 1146 } 1147 }, 1148 "Callouts": [ 1149 { 1150 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1151 } 1152 ], 1153 "Documentation": 1154 { 1155 "Description": "The system has failed to reboot the host firmware", 1156 "Message": "The system has failed to reboot the host firmware, look for other errors", 1157 "Notes": [ 1158 "This log indicates a critical BMC application required ", 1159 "to reboot the host firmware has failed to start ", 1160 "successfully. Look in the log for other errors indicating ", 1161 "what has failed." 1162 ] 1163 } 1164 }, 1165 1166 { 1167 "Name": "xyz.openbmc_project.State.Error.HostQuiesce", 1168 "Subsystem": "bmc_firmware", 1169 "ComponentID": "0x3400", 1170 "SRC": 1171 { 1172 "ReasonCode": "0x3414", 1173 "Words6To9": 1174 { 1175 } 1176 }, 1177 "Callouts": [ 1178 { 1179 "CalloutList": [{"Priority": "high", "Procedure": "next_level_support"}] 1180 } 1181 ], 1182 "Documentation": 1183 { 1184 "Description": "The host firmware has failed to boot", 1185 "Message": "The host firmware has failed to boot and has entered a Quiesce state. Look for other errors.", 1186 "Notes": [ 1187 "This log indicates that the host firmware has failed to ", 1188 "boot and all retries have been exhausted. There should be ", 1189 "other logs with more details on the boot failure reason. " 1190 ] 1191 } 1192 }, 1193 1194 { 1195 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 1196 "Subsystem": "processor_chip", 1197 "ComponentID": "0x3500", 1198 1199 "SRC": 1200 { 1201 "ReasonCode": "0x3500", 1202 "Words6To9": 1203 { 1204 "6": 1205 { 1206 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1207 "AdditionalDataPropSource": "SRC6" 1208 } 1209 } 1210 }, 1211 1212 "Documentation": 1213 { 1214 "Description": "chipop failure with SBE provided FFDC", 1215 "Message": "chipop request failure reported by SBE", 1216 "Notes": [ 1217 "The severity is set by the creator.", 1218 "Callouts added based on SBE provided FFDC.", 1219 "SBE provided additional debug data included as part of the", 1220 "additional user data section." 1221 ] 1222 } 1223 }, 1224 1225 { 1226 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 1227 "Subsystem": "processor_chip", 1228 "ComponentID": "0x3500", 1229 1230 "SRC": 1231 { 1232 "ReasonCode": "0x3501", 1233 "Words6To9": 1234 { 1235 "6": 1236 { 1237 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1238 "AdditionalDataPropSource": "SRC6" 1239 } 1240 } 1241 }, 1242 1243 "Callouts": [ 1244 { 1245 "CalloutList": [ 1246 { "Priority": "high", "Procedure": "next_level_support" } 1247 ] 1248 } 1249 ], 1250 1251 "Documentation": 1252 { 1253 "Description": "SBE chipop timeout", 1254 "Message": "chipop timeout reported during SBE communication", 1255 "Notes": [ 1256 "The severity is set by the creator.", 1257 "Check SBE Dump associated to this error to debug the failure." 1258 ] 1259 } 1260 }, 1261 1262 { 1263 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 1264 "Subsystem": "processor_chip", 1265 "ComponentID": "0x3500", 1266 1267 "SRC": 1268 { 1269 "ReasonCode": "0x3502", 1270 "Words6To9": 1271 { 1272 "6": 1273 { 1274 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 1275 "AdditionalDataPropSource": "SRC6" 1276 }, 1277 "7": 1278 { 1279 "Description": "Value of SBE state", 1280 "AdditionalDataPropSource": "SRC7" 1281 } 1282 } 1283 }, 1284 1285 "Documentation": 1286 { 1287 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 1288 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 1289 "Notes": [ 1290 "The severity is set by the creator." 1291 ] 1292 } 1293 }, 1294 1295 { 1296 "Name": "org.open_power.Processor.Error.SbeBootFailure", 1297 "Subsystem": "processor_chip", 1298 "ComponentID": "0x3500", 1299 1300 "SRC": 1301 { 1302 "ReasonCode": "0x3503", 1303 "Words6To9": 1304 { 1305 "6": 1306 { 1307 "Description": "[0:15] chip position", 1308 "AdditionalDataPropSource": "SRC6" 1309 } 1310 } 1311 }, 1312 1313 "Documentation": 1314 { 1315 "Description": "Boot failure with SBE provided FFDC", 1316 "Message": "Boot failure reported by SBE", 1317 "Notes": [ 1318 "The severity is set by the creator.", 1319 "Callouts added based on SBE provided FFDC.", 1320 "SBE provided additional debug data included as part of the", 1321 "additional user data section." 1322 ] 1323 } 1324 }, 1325 1326 { 1327 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 1328 "Subsystem": "processor_chip", 1329 "ComponentID": "0x3500", 1330 1331 "SRC": 1332 { 1333 "ReasonCode": "0x3504", 1334 "Words6To9": 1335 { 1336 } 1337 }, 1338 1339 "Callouts": [ 1340 { 1341 "System": "ibm,rainier", 1342 "CalloutList": [ 1343 { 1344 "Priority": "low", 1345 "LocCode": "P0" 1346 }, 1347 { 1348 "Priority": "low", 1349 "LocCode": "P0-C22" 1350 } 1351 ] 1352 }, 1353 { 1354 "System": "ibm,everest", 1355 "CalloutList": [ 1356 { 1357 "Priority": "low", 1358 "LocCode": "P0" 1359 }, 1360 { 1361 "Priority": "low", 1362 "LocCode": "P0-C96" 1363 } 1364 ] 1365 } 1366 ], 1367 1368 "Documentation": 1369 { 1370 "Description": "SBE Boot timeout", 1371 "Message": "timeout reported during SBE boot process", 1372 "Notes": [ 1373 "The severity is set by the creator.", 1374 "Check SBE Dump associated to this error to debug the failure." 1375 ] 1376 } 1377 }, 1378 1379 { 1380 "Name": "org.open_power.Attn.Error.Terminate", 1381 "Subsystem": "cec_hardware", 1382 "Severity": "non_error", 1383 1384 "SRC": 1385 { 1386 "ReasonCode": "0xD138", 1387 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 1388 "Words6To9": 1389 { 1390 } 1391 }, 1392 1393 "Documentation": 1394 { 1395 "Description": "Status shows TI special attention active", 1396 "Message": "TI special attention detected", 1397 "Notes": [ 1398 "This entry is for any TI special attention event ", 1399 "reported by the attention handler component" 1400 ] 1401 } 1402 }, 1403 1404 { 1405 "Name": "org.open_power.Attn.Error.Fail", 1406 "Subsystem": "bmc_firmware", 1407 "Severity": "unrecoverable_loss_of_function", 1408 1409 "SRC": 1410 { 1411 "ReasonCode": "0xD13E", 1412 "Words6To9": 1413 { 1414 "6": 1415 { 1416 "Description": "Error code from attention handler", 1417 "AdditionalDataPropSource": "ERROR_CODE" 1418 } 1419 } 1420 }, 1421 "Documentation": 1422 { 1423 "Description": "The attention handler encountered an error", 1424 "MessageArgSources" : ["SRCWord6"], 1425 "Message": "Attention handler error %1", 1426 "Notes": [ 1427 "Attention handler will provide error code" 1428 ] 1429 } 1430 }, 1431 1432 { 1433 "Name": "org.open_power.Attn.Error.Vital", 1434 "Subsystem": "processor_chip", 1435 "Severity": "critical", 1436 1437 "SRC": 1438 { 1439 "ReasonCode": "0xD16D", 1440 "Words6To9": 1441 { 1442 } 1443 }, 1444 1445 "Documentation": 1446 { 1447 "Description": "Status shows SBE vital attention active", 1448 "Message": "SBE vital attention detected", 1449 "Notes": [ 1450 "This entry is for any SBE vital attention event ", 1451 "reported by the attention handler component" 1452 ] 1453 } 1454 }, 1455 1456 { 1457 "Name": "org.open_power.HwDiags.Error.Checkstop", 1458 "PossibleSubsystems": [ 1459 "processor", "processor_fru", "processor_unit", "processor_bus", 1460 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1461 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1462 ], 1463 "Severity": "unrecoverable", 1464 "ActionFlags": [ "service_action", "report", "call_home" ], 1465 1466 "SRC": 1467 { 1468 "ReasonCode": "0xE510", 1469 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1470 "Words6To9": 1471 { 1472 "6": 1473 { 1474 "AdditionalDataPropSource": "SRC6" 1475 }, 1476 "7": 1477 { 1478 "AdditionalDataPropSource": "SRC7" 1479 }, 1480 "8": 1481 { 1482 "AdditionalDataPropSource": "SRC8" 1483 } 1484 } 1485 }, 1486 1487 "Documentation": 1488 { 1489 "Description": "A system checkstop attention has occurred", 1490 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1491 "Message": "Error Signature: %1 %2 %3" 1492 } 1493 }, 1494 1495 { 1496 "Name": "org.open_power.HwDiags.Error.Predictive", 1497 "PossibleSubsystems": [ 1498 "processor", "processor_fru", "processor_unit", "processor_bus", 1499 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1500 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1501 ], 1502 "Severity": "predictive", 1503 "ActionFlags": [ "service_action", "report", "call_home" ], 1504 1505 "SRC": 1506 { 1507 "ReasonCode": "0xE511", 1508 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1509 "Words6To9": 1510 { 1511 "6": 1512 { 1513 "AdditionalDataPropSource": "SRC6" 1514 }, 1515 "7": 1516 { 1517 "AdditionalDataPropSource": "SRC7" 1518 }, 1519 "8": 1520 { 1521 "AdditionalDataPropSource": "SRC8" 1522 } 1523 } 1524 }, 1525 1526 "Documentation": 1527 { 1528 "Description": "A hardware attention requiring service has occurred", 1529 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1530 "Message": "Error Signature: %1 %2 %3" 1531 } 1532 }, 1533 1534 { 1535 "Name": "org.open_power.HwDiags.Error.Informational", 1536 "PossibleSubsystems": [ 1537 "processor", "processor_fru", "processor_unit", "processor_bus", 1538 "memory_ctlr", "memory_bus", "memory_dimm", "memory_fru", 1539 "phb", "cec_hardware", "cec_clocks", "cec_tod", "others" 1540 ], 1541 "Severity": "non_error", 1542 "ActionFlags": [ "hidden", "dont_report" ], 1543 1544 "SRC": 1545 { 1546 "ReasonCode": "0xE512", 1547 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1548 "Words6To9": 1549 { 1550 "6": 1551 { 1552 "AdditionalDataPropSource": "SRC6" 1553 }, 1554 "7": 1555 { 1556 "AdditionalDataPropSource": "SRC7" 1557 }, 1558 "8": 1559 { 1560 "AdditionalDataPropSource": "SRC8" 1561 } 1562 } 1563 }, 1564 1565 "Documentation": 1566 { 1567 "Description": "Manual analysis was initiated via the command line. FFDC only.", 1568 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 1569 "Message": "Error Signature: %1 %2 %3" 1570 } 1571 }, 1572 1573 { 1574 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 1575 "Subsystem": "power_supply", 1576 "ActionFlags": ["service_action", "report"], 1577 "ComponentID": "0x2700", 1578 1579 "SRC": { 1580 "Type": "11", 1581 "ReasonCode": "0x15F0", 1582 "Words6To9": {} 1583 }, 1584 1585 "Callouts": [ 1586 { 1587 "CalloutList": [ 1588 { "Priority": "high", "SymbolicFRU": "pwrsply" } 1589 ] 1590 } 1591 ], 1592 1593 "Documentation": { 1594 "Description": "Power Supply input power fault", 1595 "Message": "A power supply has indicated an input or under voltage condition.", 1596 "Notes": [ 1597 "Check the power supply cabling and/or input power ", 1598 "source. The PWRSPLY procedure is used rather than ", 1599 "calling out a location code, as typically these faults ", 1600 "are related to the supplied power, the cable, or the ", 1601 "cable connectors. If the input fault resolves down to an ", 1602 "issue with the power supply itself, the power supply ", 1603 "indicating this input fault should be called out. Add the ", 1604 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 1605 "CALLOUT_PRIORITY to something other than high." 1606 ] 1607 } 1608 }, 1609 1610 { 1611 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 1612 "Subsystem": "power_supply", 1613 "ActionFlags": ["service_action", "report", "call_home"], 1614 "ComponentID": "0x2700", 1615 1616 "SRC": { 1617 "Type": "11", 1618 "ReasonCode": "0x15F1", 1619 "Words6To9": {} 1620 }, 1621 1622 "Callouts": [ 1623 { 1624 "CalloutList": [ 1625 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1626 ] 1627 } 1628 ], 1629 1630 "Documentation": { 1631 "Description": "Power Supply power fault", 1632 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 1633 "Notes": [ 1634 "The power supply reporting the fault should be called ", 1635 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1636 "specific fault, STATUS_* details, and code level in the ", 1637 "AdditionalData section." 1638 ] 1639 } 1640 }, 1641 1642 { 1643 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 1644 "Subsystem": "power_supply", 1645 "ActionFlags": ["service_action", "report", "call_home"], 1646 "ComponentID": "0x2700", 1647 1648 "SRC": { 1649 "Type": "11", 1650 "ReasonCode": "0x15F2", 1651 "Words6To9": {} 1652 }, 1653 1654 "Callouts": [ 1655 { 1656 "CalloutList": [ 1657 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1658 ] 1659 } 1660 ], 1661 1662 "Documentation": { 1663 "Description": "Power Supply non-power fault", 1664 "Message": "A communication failure occurred talking to the power supply", 1665 "Notes": [ 1666 "Communication problems with the power supply could be ", 1667 "the power supply, or any hardware between it and the ", 1668 "BMC. Reporting the error should be passing in a call ", 1669 "out using CALLOUT_DEVICE_PATH." 1670 ] 1671 } 1672 }, 1673 1674 { 1675 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 1676 "Subsystem": "power_supply", 1677 "ActionFlags": ["service_action", "report", "call_home"], 1678 "ComponentID": "0x2700", 1679 1680 "SRC": { 1681 "Type": "11", 1682 "ReasonCode": "0x15F6", 1683 "Words6To9": {} 1684 }, 1685 1686 "Callouts": [ 1687 { 1688 "CalloutList": [ 1689 { 1690 "Priority": "high", 1691 "SymbolicFRUTrusted": "pwrsply", 1692 "UseInventoryLocCode": true 1693 } 1694 ] 1695 } 1696 ], 1697 1698 "Documentation": { 1699 "Description": "Power Supply is missing", 1700 "Message": "A power supply that should be present is missing", 1701 "Notes": [ 1702 "The CalloutList should use the PWRSPLY symbolic FRU ", 1703 "with the trusted location code property. The ", 1704 "location code in this callout is obtained from ", 1705 "the passed in CALLOUT_INVENTORY_PATH value." 1706 ] 1707 } 1708 }, 1709 1710 { 1711 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 1712 "Subsystem": "power_supply", 1713 "ActionFlags": ["service_action", "report", "call_home"], 1714 "ComponentID": "0x2700", 1715 1716 "SRC": { 1717 "Type": "11", 1718 "ReasonCode": "0x15F7", 1719 "Words6To9": {} 1720 }, 1721 1722 "Callouts": [ 1723 { 1724 "CalloutList": [ 1725 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1726 ] 1727 } 1728 ], 1729 1730 "Documentation": { 1731 "Description": "Power Supply configuration is not supported", 1732 "Message": "The power supply configuration is not supported", 1733 "Notes": [ 1734 "The combination of power supplies detected in the ", 1735 "system is not supported. This could be caused by ", 1736 "mismatched models, less than expected number of power ", 1737 "supplies, or other unsupported characteristics." 1738 ] 1739 } 1740 }, 1741 1742 { 1743 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.FanFault", 1744 "Subsystem": "power_supply", 1745 "ActionFlags": ["service_action", "report", "call_home"], 1746 "ComponentID": "0x2700", 1747 1748 "SRC": { 1749 "Type": "11", 1750 "ReasonCode": "0x15FF", 1751 "Words6To9": {} 1752 }, 1753 1754 "Callouts": [ 1755 { 1756 "CalloutList": [ 1757 { "Priority": "medium", "SymbolicFRU": "pwrsply" } 1758 ] 1759 } 1760 ], 1761 1762 "Documentation": { 1763 "Description": "Power Supply fan fault", 1764 "Message": "A power supply indicated a fan fault has occurred", 1765 "Notes": [ 1766 "The power supply reporting the fault should be called ", 1767 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 1768 "specific fault, STATUS_* details, and code level in the ", 1769 "AdditionalData section." 1770 ] 1771 } 1772 }, 1773 1774 { 1775 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 1776 "Subsystem": "power_supply", 1777 "ActionFlags": ["service_action", "report", "call_home"], 1778 "ComponentID": "0x2700", 1779 1780 "SRC": { 1781 "Type": "11", 1782 "ReasonCode": "0x1B01", 1783 "Words6To9": {} 1784 }, 1785 1786 "Callouts": [ 1787 { 1788 "CalloutList": [ 1789 { "Priority": "high", "Procedure": "power_overcurrent" } 1790 ] 1791 } 1792 ], 1793 1794 "Documentation": { 1795 "Description": "Power Supply output over-current power fault", 1796 "Message": "A power supply has indicated an output over-current condition." 1797 } 1798 }, 1799 1800 { 1801 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1802 "Subsystem": "power", 1803 "ActionFlags": [ "report", "service_action" ], 1804 "ComponentID": "0x2700", 1805 1806 "SRC": 1807 { 1808 "Type": "11", 1809 "ReasonCode": "0x00AC", 1810 "Words6To9": {} 1811 }, 1812 1813 "Callouts": [ 1814 { 1815 "CalloutList": [ 1816 { "Priority": "high", "SymbolicFRU": "ac_module"} 1817 ] 1818 } 1819 ], 1820 1821 "Documentation": { 1822 "Description": "Input power was lost while the system was powered on.", 1823 "Message": "Input power was lost while the system was powered on.", 1824 "Notes": [ 1825 "Input power was lost while system powered on.", 1826 "The CalloutList should use the ACMODUL symbolic FRU." 1827 ] 1828 } 1829 }, 1830 1831 { 1832 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1833 "Subsystem": "power_supply", 1834 "ActionFlags": ["service_action", "report", "call_home"], 1835 "ComponentID": "0x2700", 1836 1837 "SRC": { 1838 "Type": "11", 1839 "ReasonCode": "0x2500", 1840 "Words6To9": {} 1841 }, 1842 1843 "Callouts": [ 1844 { 1845 "CalloutList": [ 1846 { "Priority": "high", "Procedure": "power_overcurrent" } 1847 ] 1848 } 1849 ], 1850 1851 "Documentation": { 1852 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1853 "Message": "Power supply PSKill_fault", 1854 "Notes": [ 1855 ] 1856 } 1857 }, 1858 1859 { 1860 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1861 "Subsystem": "power_sequencer", 1862 "ComponentID": "0x2700", 1863 1864 "SRC": { 1865 "Type": "11", 1866 "ReasonCode": "0x2600", 1867 "Words6To9": {} 1868 }, 1869 1870 "Callouts": [ 1871 { 1872 "CalloutList": [ 1873 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1874 ] 1875 } 1876 ], 1877 1878 "Documentation": { 1879 "Description": "A power off was issued because a power fault was detected", 1880 "Message": "A power off was issued because a power fault was detected", 1881 "Notes": [ 1882 ] 1883 } 1884 }, 1885 1886 { 1887 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1888 "Subsystem": "power_control_hw", 1889 "Severity": "critical_system_term", 1890 "ComponentID": "0x2700", 1891 1892 "SRC": { 1893 "Type": "11", 1894 "ReasonCode": "0x2602", 1895 "Words6To9": {} 1896 }, 1897 1898 "Callouts": [ 1899 { 1900 "System": "ibm,rainier", 1901 "CalloutList": [ 1902 { 1903 "Priority": "high", 1904 "LocCode": "P0-C5" 1905 }, 1906 { 1907 "Priority": "medium", 1908 "LocCode": "P0" 1909 } 1910 ] 1911 }, 1912 { 1913 "System": "ibm,everest", 1914 "CalloutList": [ 1915 { 1916 "Priority": "high", 1917 "LocCode": "P0-C59" 1918 }, 1919 { 1920 "Priority": "medium", 1921 "LocCode": "P0" 1922 } 1923 ] 1924 } 1925 ], 1926 1927 "Documentation": { 1928 "Description": "A power off was issued because a regulator for standby power faulted", 1929 "Message": "A power off was issued because a regulator for standby power faulted", 1930 "Notes": [ 1931 ] 1932 } 1933 }, 1934 1935 { 1936 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1937 "Subsystem": "power_sequencer", 1938 "ComponentID": "0x2700", 1939 1940 "SRC": { 1941 "Type": "11", 1942 "ReasonCode": "0x2610", 1943 "Words6To9": {} 1944 }, 1945 1946 "CalloutsUsingAD": { 1947 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1948 { 1949 "ADValue": "PCIE_SLOT0", "Callouts": [ 1950 { 1951 "CalloutList": [ 1952 { "Priority": "high", "LocCode": "P0-C0" }, 1953 { "Priority": "medium", "LocCode": "P0" } 1954 ] 1955 } 1956 ] 1957 }, 1958 { 1959 "ADValue": "PCIE_SLOT1", "Callouts": [ 1960 { 1961 "CalloutList": [ 1962 { "Priority": "high", "LocCode": "P0-C1" }, 1963 { "Priority": "medium", "LocCode": "P0" } 1964 ] 1965 } 1966 ] 1967 }, 1968 { 1969 "ADValue": "PCIE_SLOT2", "Callouts": [ 1970 { 1971 "CalloutList": [ 1972 { "Priority": "high", "LocCode": "P0-C2" }, 1973 { "Priority": "medium", "LocCode": "P0" } 1974 ] 1975 } 1976 ] 1977 }, 1978 { 1979 "ADValue": "PCIE_SLOT3", "Callouts": [ 1980 { 1981 "CalloutList": [ 1982 { "Priority": "high", "LocCode": "P0-C3" }, 1983 { "Priority": "medium", "LocCode": "P0" } 1984 ] 1985 } 1986 ] 1987 }, 1988 { 1989 "ADValue": "PCIE_SLOT4", "Callouts": [ 1990 { 1991 "CalloutList": [ 1992 { "Priority": "high", "LocCode": "P0-C4" }, 1993 { "Priority": "medium", "LocCode": "P0" } 1994 ] 1995 } 1996 ] 1997 }, 1998 { 1999 "ADValue": "PCIE_SLOT5", "Callouts": [ 2000 { 2001 "CalloutList": [ 2002 { "Priority": "high", "LocCode": "P0-C5" }, 2003 { "Priority": "medium", "LocCode": "P0" } 2004 ] 2005 } 2006 ] 2007 }, 2008 { 2009 "ADValue": "PCIE_SLOT6", "Callouts": [ 2010 { 2011 "CalloutList": [ 2012 { "Priority": "high", "LocCode": "P0-C6" }, 2013 { "Priority": "medium", "LocCode": "P0" } 2014 ] 2015 } 2016 ] 2017 }, 2018 { 2019 "ADValue": "PCIE_SLOT7", "Callouts": [ 2020 { 2021 "CalloutList": [ 2022 { "Priority": "high", "LocCode": "P0-C7" }, 2023 { "Priority": "medium", "LocCode": "P0" } 2024 ] 2025 } 2026 ] 2027 }, 2028 { 2029 "ADValue": "PCIE_SLOT8", "Callouts": [ 2030 { 2031 "CalloutList": [ 2032 { "Priority": "high", "LocCode": "P0-C8" }, 2033 { "Priority": "medium", "LocCode": "P0" } 2034 ] 2035 } 2036 ] 2037 }, 2038 { 2039 "ADValue": "PCIE_SLOT9", "Callouts": [ 2040 { 2041 "CalloutList": [ 2042 { "Priority": "high", "LocCode": "P0-C9" }, 2043 { "Priority": "medium", "LocCode": "P0" } 2044 ] 2045 } 2046 ] 2047 }, 2048 { 2049 "ADValue": "PCIE_SLOT10", "Callouts": [ 2050 { 2051 "CalloutList": [ 2052 { "Priority": "high", "LocCode": "P0-C10" }, 2053 { "Priority": "medium", "LocCode": "P0" } 2054 ] 2055 } 2056 ] 2057 }, 2058 { 2059 "ADValue": "PCIE_SLOT11", "Callouts": [ 2060 { 2061 "CalloutList": [ 2062 { "Priority": "high", "LocCode": "P0-C11" }, 2063 { "Priority": "medium", "LocCode": "P0" } 2064 ] 2065 } 2066 ] 2067 }, 2068 { 2069 "ADValue": "PGOOD_12A", "Callouts": [ 2070 { 2071 "CalloutList": [ 2072 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2073 ] 2074 } 2075 ] 2076 }, 2077 { 2078 "ADValue": "PGOOD_12B", "Callouts": [ 2079 { 2080 "CalloutList": [ 2081 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2082 ] 2083 } 2084 ] 2085 }, 2086 { 2087 "ADValue": "PGOOD_12C", "Callouts": [ 2088 { 2089 "CalloutList": [ 2090 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2091 ] 2092 } 2093 ] 2094 }, 2095 { 2096 "ADValue": "PGOOD_12D", "Callouts": [ 2097 { 2098 "CalloutList": [ 2099 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2100 ] 2101 } 2102 ] 2103 }, 2104 { 2105 "ADValue": "PGOOD_12L", "Callouts": [ 2106 { 2107 "CalloutList": [ 2108 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2109 ] 2110 } 2111 ] 2112 }, 2113 { 2114 "ADValue": "PGOOD_12M", "Callouts": [ 2115 { 2116 "CalloutList": [ 2117 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2118 ] 2119 } 2120 ] 2121 }, 2122 { 2123 "ADValue": "PGOOD_12N", "Callouts": [ 2124 { 2125 "CalloutList": [ 2126 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2127 ] 2128 } 2129 ] 2130 }, 2131 { 2132 "ADValue": "PGOOD_12P", "Callouts": [ 2133 { 2134 "CalloutList": [ 2135 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2136 ] 2137 } 2138 ] 2139 }, 2140 { 2141 "ADValue": "PGOOD_12PCIE", "Callouts": [ 2142 { 2143 "CalloutList": [ 2144 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2145 ] 2146 } 2147 ] 2148 }, 2149 { 2150 "ADValue": "PGOOD_12Q", "Callouts": [ 2151 { 2152 "CalloutList": [ 2153 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2154 ] 2155 } 2156 ] 2157 }, 2158 { 2159 "ADValue": "PGOOD_12R", "Callouts": [ 2160 { 2161 "CalloutList": [ 2162 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2163 ] 2164 } 2165 ] 2166 }, 2167 { 2168 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 2169 { 2170 "CalloutList": [ 2171 { "Priority": "high", "LocCode": "P0-C14" }, 2172 { "Priority": "medium", "LocCode": "P0-C15" }, 2173 { "Priority": "low", "LocCode": "P0" } 2174 ] 2175 } 2176 ] 2177 }, 2178 { 2179 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 2180 { 2181 "CalloutList": [ 2182 { "Priority": "high", "LocCode": "P0-C23" }, 2183 { "Priority": "medium", "LocCode": "P0-C24" }, 2184 { "Priority": "low", "LocCode": "P0" } 2185 ] 2186 } 2187 ] 2188 }, 2189 { 2190 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 2191 { 2192 "CalloutList": [ 2193 { "Priority": "high", "LocCode": "P0-C14" }, 2194 { "Priority": "medium", "LocCode": "P0-C15" }, 2195 { "Priority": "low", "LocCode": "P0" } 2196 ] 2197 } 2198 ] 2199 }, 2200 { 2201 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 2202 { 2203 "CalloutList": [ 2204 { "Priority": "high", "LocCode": "P0-C23" }, 2205 { "Priority": "medium", "LocCode": "P0-C24" }, 2206 { "Priority": "low", "LocCode": "P0" } 2207 ] 2208 } 2209 ] 2210 }, 2211 { 2212 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 2213 { 2214 "CalloutList": [ 2215 { "Priority": "high", "LocCode": "P0-C14" }, 2216 { "Priority": "medium", "LocCode": "P0-C15" }, 2217 { "Priority": "low", "LocCode": "P0" } 2218 ] 2219 } 2220 ] 2221 }, 2222 { 2223 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 2224 { 2225 "CalloutList": [ 2226 { "Priority": "high", "LocCode": "P0-C23" }, 2227 { "Priority": "medium", "LocCode": "P0-C24" }, 2228 { "Priority": "low", "LocCode": "P0" } 2229 ] 2230 } 2231 ] 2232 }, 2233 { 2234 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 2235 { 2236 "CalloutList": [ 2237 { "Priority": "high", "LocCode": "P0-C14" }, 2238 { "Priority": "medium", "LocCode": "P0-C15" }, 2239 { "Priority": "low", "LocCode": "P0" } 2240 ] 2241 } 2242 ] 2243 }, 2244 { 2245 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 2246 { 2247 "CalloutList": [ 2248 { "Priority": "high", "LocCode": "P0-C23" }, 2249 { "Priority": "medium", "LocCode": "P0-C24" }, 2250 { "Priority": "low", "LocCode": "P0" } 2251 ] 2252 } 2253 ] 2254 }, 2255 { 2256 "ADValue": "CP0_VPCIE", "Callouts": [ 2257 { 2258 "CalloutList": [ 2259 { "Priority": "high", "LocCode": "P0-C58" }, 2260 { "Priority": "medium", "LocCode": "P0-C61" }, 2261 { "Priority": "low", "LocCode": "P0" } 2262 ] 2263 } 2264 ] 2265 }, 2266 { 2267 "ADValue": "CP1_VPCIE", "Callouts": [ 2268 { 2269 "CalloutList": [ 2270 { "Priority": "high", "LocCode": "P0-C16" }, 2271 { "Priority": "medium", "LocCode": "P0-C14" }, 2272 { "Priority": "low", "LocCode": "P0" } 2273 ] 2274 } 2275 ] 2276 }, 2277 { 2278 "ADValue": "CP2_VPCIE", "Callouts": [ 2279 { 2280 "CalloutList": [ 2281 { "Priority": "high", "LocCode": "P0-C16" }, 2282 { "Priority": "medium", "LocCode": "P0-C19" }, 2283 { "Priority": "low", "LocCode": "P0" } 2284 ] 2285 } 2286 ] 2287 }, 2288 { 2289 "ADValue": "CP3_VPCIE", "Callouts": [ 2290 { 2291 "CalloutList": [ 2292 { "Priority": "high", "LocCode": "P0-C58" }, 2293 { "Priority": "medium", "LocCode": "P0-C56" }, 2294 { "Priority": "low", "LocCode": "P0" } 2295 ] 2296 } 2297 ] 2298 }, 2299 { 2300 "ADValue": "5.0V_USB_front", "Callouts": [ 2301 { 2302 "CalloutList": [ 2303 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2304 { "Priority": "low", "LocCode": "P1" }, 2305 { "Priority": "low", "LocCode": "P0" } 2306 ] 2307 } 2308 ] 2309 }, 2310 { 2311 "ADValue": "CP0_VDN", "Callouts": [ 2312 { 2313 "CalloutList": [ 2314 { "Priority": "high", "LocCode": "P0-C63" }, 2315 { "Priority": "medium", "LocCode": "P0-C61" }, 2316 { "Priority": "low", "LocCode": "P0" } 2317 ] 2318 } 2319 ] 2320 }, 2321 { 2322 "ADValue": "CP1_VDN", "Callouts": [ 2323 { 2324 "CalloutList": [ 2325 { "Priority": "high", "LocCode": "P0-C12" }, 2326 { "Priority": "medium", "LocCode": "P0-C14" }, 2327 { "Priority": "low", "LocCode": "P0" } 2328 ] 2329 } 2330 ] 2331 }, 2332 { 2333 "ADValue": "CP2_VDN", "Callouts": [ 2334 { 2335 "CalloutList": [ 2336 { "Priority": "high", "LocCode": "P0-C21" }, 2337 { "Priority": "medium", "LocCode": "P0-C19" }, 2338 { "Priority": "low", "LocCode": "P0" } 2339 ] 2340 } 2341 ] 2342 }, 2343 { 2344 "ADValue": "CP3_VDN", "Callouts": [ 2345 { 2346 "CalloutList": [ 2347 { "Priority": "high", "LocCode": "P0-C54" }, 2348 { "Priority": "medium", "LocCode": "P0-C56" }, 2349 { "Priority": "low", "LocCode": "P0" } 2350 ] 2351 } 2352 ] 2353 }, 2354 { 2355 "ADValue": "CP0_VIO", "Callouts": [ 2356 { 2357 "CalloutList": [ 2358 { "Priority": "high", "LocCode": "P0-C63" }, 2359 { "Priority": "medium", "LocCode": "P0-C61" }, 2360 { "Priority": "low", "LocCode": "P0" } 2361 ] 2362 } 2363 ] 2364 }, 2365 { 2366 "ADValue": "CP1_VIO", "Callouts": [ 2367 { 2368 "CalloutList": [ 2369 { "Priority": "high", "LocCode": "P0-C12" }, 2370 { "Priority": "medium", "LocCode": "P0-C14" }, 2371 { "Priority": "low", "LocCode": "P0" } 2372 ] 2373 } 2374 ] 2375 }, 2376 { 2377 "ADValue": "CP2_VIO", "Callouts": [ 2378 { 2379 "CalloutList": [ 2380 { "Priority": "high", "LocCode": "P0-C21" }, 2381 { "Priority": "medium", "LocCode": "P0-C19" }, 2382 { "Priority": "low", "LocCode": "P0" } 2383 ] 2384 } 2385 ] 2386 }, 2387 { 2388 "ADValue": "CP3_VIO", "Callouts": [ 2389 { 2390 "CalloutList": [ 2391 { "Priority": "high", "LocCode": "P0-C54" }, 2392 { "Priority": "medium", "LocCode": "P0-C56" }, 2393 { "Priority": "low", "LocCode": "P0" } 2394 ] 2395 } 2396 ] 2397 }, 2398 { 2399 "ADValue": "PGOOD_PSU1", "Callouts": [ 2400 { 2401 "CalloutList": [ 2402 { "Priority": "high", "LocCode": "E0" } 2403 ] 2404 } 2405 ] 2406 }, 2407 { 2408 "ADValue": "PGOOD_PSU2", "Callouts": [ 2409 { 2410 "CalloutList": [ 2411 { "Priority": "high", "LocCode": "E1" } 2412 ] 2413 } 2414 ] 2415 }, 2416 { 2417 "ADValue": "PGOOD_PSU3", "Callouts": [ 2418 { 2419 "CalloutList": [ 2420 { "Priority": "high", "LocCode": "E2" } 2421 ] 2422 } 2423 ] 2424 }, 2425 { 2426 "ADValue": "PGOOD_PSU4", "Callouts": [ 2427 { 2428 "CalloutList": [ 2429 { "Priority": "high", "LocCode": "E3" } 2430 ] 2431 } 2432 ] 2433 } 2434 ] 2435 }, 2436 2437 "Documentation": { 2438 "Description": "The power sequencer chip detected a PGOOD fault", 2439 "Message": "The power sequencer chip detected a PGOOD fault", 2440 "Notes": [ 2441 ] 2442 } 2443 }, 2444 2445 { 2446 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 2447 "Subsystem": "power_sequencer", 2448 "ComponentID": "0x2700", 2449 2450 "SRC": { 2451 "Type": "11", 2452 "ReasonCode": "0x2620", 2453 "Words6To9": {} 2454 }, 2455 2456 "CalloutsUsingAD": { 2457 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 2458 { 2459 "ADValue": "12.0V", "Callouts": [ 2460 { 2461 "CalloutList": [ 2462 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2463 ] 2464 } 2465 ] 2466 }, 2467 { 2468 "ADValue": "5.0V_USB", "Callouts": [ 2469 { 2470 "CalloutList": [ 2471 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2472 { "Priority": "medium", "LocCode": "P0" } 2473 ] 2474 } 2475 ] 2476 }, 2477 { 2478 "ADValue": "5.0V_DASD", "Callouts": [ 2479 { 2480 "CalloutList": [ 2481 { "Priority": "medium", "LocCode": "P1" }, 2482 { "Priority": "medium", "LocCode": "P2" }, 2483 { "Priority": "low", "LocCode": "P0" } 2484 ] 2485 } 2486 ] 2487 }, 2488 { 2489 "ADValue": "3.3VA", "Callouts": [ 2490 { 2491 "CalloutList": [ 2492 { "Priority": "high", "LocCode": "P0" } 2493 ] 2494 } 2495 ] 2496 }, 2497 { 2498 "ADValue": "3.3VB", "Callouts": [ 2499 { 2500 "CalloutList": [ 2501 { "Priority": "high", "LocCode": "P0" } 2502 ] 2503 } 2504 ] 2505 }, 2506 { 2507 "ADValue": "3V3IO", "Callouts": [ 2508 { 2509 "CalloutList": [ 2510 { "Priority": "high", "LocCode": "P0-C17" }, 2511 { "Priority": "medium", "LocCode": "P0-C96" }, 2512 { "Priority": "medium", "LocCode": "P0-C0" }, 2513 { "Priority": "medium", "SymbolicFRU": "pcie_hot_plug" }, 2514 { "Priority": "low", "LocCode": "P0" } 2515 ] 2516 } 2517 ] 2518 }, 2519 { 2520 "ADValue": "1.5V", "Callouts": [ 2521 { 2522 "CalloutList": [ 2523 { "Priority": "high", "LocCode": "P0" } 2524 ] 2525 } 2526 ] 2527 }, 2528 { 2529 "ADValue": "1.1V", "Callouts": [ 2530 { 2531 "CalloutList": [ 2532 { "Priority": "high", "LocCode": "P0" } 2533 ] 2534 } 2535 ] 2536 }, 2537 { 2538 "ADValue": "VDDA_DCM0", "Callouts": [ 2539 { 2540 "CalloutList": [ 2541 { "Priority": "high", "LocCode": "P0-C14" }, 2542 { "Priority": "medium", "LocCode": "P0-C15" }, 2543 { "Priority": "low", "LocCode": "P0" } 2544 ] 2545 } 2546 ] 2547 }, 2548 { 2549 "ADValue": "VDDB_DCM0", "Callouts": [ 2550 { 2551 "CalloutList": [ 2552 { "Priority": "high", "LocCode": "P0-C14" }, 2553 { "Priority": "medium", "LocCode": "P0-C15" }, 2554 { "Priority": "low", "LocCode": "P0" } 2555 ] 2556 } 2557 ] 2558 }, 2559 { 2560 "ADValue": "VDDA_DCM1", "Callouts": [ 2561 { 2562 "CalloutList": [ 2563 { "Priority": "high", "LocCode": "P0-C23" }, 2564 { "Priority": "medium", "LocCode": "P0-C24" }, 2565 { "Priority": "low", "LocCode": "P0" } 2566 ] 2567 } 2568 ] 2569 }, 2570 { 2571 "ADValue": "VDDB_DCM1", "Callouts": [ 2572 { 2573 "CalloutList": [ 2574 { "Priority": "high", "LocCode": "P0-C23" }, 2575 { "Priority": "medium", "LocCode": "P0-C24" }, 2576 { "Priority": "low", "LocCode": "P0" } 2577 ] 2578 } 2579 ] 2580 }, 2581 { 2582 "ADValue": "CP03_AVDD", "Callouts": [ 2583 { 2584 "CalloutList": [ 2585 { "Priority": "high", "LocCode": "P0-C58" }, 2586 { "Priority": "medium", "LocCode": "P0-C61" }, 2587 { "Priority": "medium", "LocCode": "P0-C56" }, 2588 { "Priority": "low", "LocCode": "P0" } 2589 ] 2590 } 2591 ] 2592 }, 2593 { 2594 "ADValue": "CP12_AVDD", "Callouts": [ 2595 { 2596 "CalloutList": [ 2597 { "Priority": "high", "LocCode": "P0-C16" }, 2598 { "Priority": "medium", "LocCode": "P0-C14" }, 2599 { "Priority": "medium", "LocCode": "P0-C19" }, 2600 { "Priority": "low", "LocCode": "P0" } 2601 ] 2602 } 2603 ] 2604 }, 2605 { 2606 "ADValue": "CP0_VDD0", "Callouts": [ 2607 { 2608 "CalloutList": [ 2609 { "Priority": "high", "LocCode": "P0-C62" }, 2610 { "Priority": "medium", "LocCode": "P0-C61" }, 2611 { "Priority": "low", "LocCode": "P0" } 2612 ] 2613 } 2614 ] 2615 }, 2616 { 2617 "ADValue": "CP0_VDD1", "Callouts": [ 2618 { 2619 "CalloutList": [ 2620 { "Priority": "high", "LocCode": "P0-C60" }, 2621 { "Priority": "medium", "LocCode": "P0-C61" }, 2622 { "Priority": "low", "LocCode": "P0" } 2623 ] 2624 } 2625 ] 2626 }, 2627 { 2628 "ADValue": "CP1_VDD0", "Callouts": [ 2629 { 2630 "CalloutList": [ 2631 { "Priority": "high", "LocCode": "P0-C13" }, 2632 { "Priority": "medium", "LocCode": "P0-C14" }, 2633 { "Priority": "low", "LocCode": "P0" } 2634 ] 2635 } 2636 ] 2637 }, 2638 { 2639 "ADValue": "CP1_VDD1", "Callouts": [ 2640 { 2641 "CalloutList": [ 2642 { "Priority": "high", "LocCode": "P0-C15" }, 2643 { "Priority": "medium", "LocCode": "P0-C14" }, 2644 { "Priority": "low", "LocCode": "P0" } 2645 ] 2646 } 2647 ] 2648 }, 2649 { 2650 "ADValue": "CP2_VDD0", "Callouts": [ 2651 { 2652 "CalloutList": [ 2653 { "Priority": "high", "LocCode": "P0-C18" }, 2654 { "Priority": "medium", "LocCode": "P0-C19" }, 2655 { "Priority": "low", "LocCode": "P0" } 2656 ] 2657 } 2658 ] 2659 }, 2660 { 2661 "ADValue": "CP2_VDD1", "Callouts": [ 2662 { 2663 "CalloutList": [ 2664 { "Priority": "high", "LocCode": "P0-C20" }, 2665 { "Priority": "medium", "LocCode": "P0-C19" }, 2666 { "Priority": "low", "LocCode": "P0" } 2667 ] 2668 } 2669 ] 2670 }, 2671 { 2672 "ADValue": "CP3_VDD0", "Callouts": [ 2673 { 2674 "CalloutList": [ 2675 { "Priority": "high", "LocCode": "P0-C57" }, 2676 { "Priority": "medium", "LocCode": "P0-C56" }, 2677 { "Priority": "low", "LocCode": "P0" } 2678 ] 2679 } 2680 ] 2681 }, 2682 { 2683 "ADValue": "CP3_VDD1", "Callouts": [ 2684 { 2685 "CalloutList": [ 2686 { "Priority": "high", "LocCode": "P0-C55" }, 2687 { "Priority": "medium", "LocCode": "P0-C56" }, 2688 { "Priority": "low", "LocCode": "P0" } 2689 ] 2690 } 2691 ] 2692 }, 2693 { 2694 "ADValue": "CP0_VCS0", "Callouts": [ 2695 { 2696 "CalloutList": [ 2697 { "Priority": "high", "LocCode": "P0-C63" }, 2698 { "Priority": "medium", "LocCode": "P0-C61" }, 2699 { "Priority": "low", "LocCode": "P0" } 2700 ] 2701 } 2702 ] 2703 }, 2704 { 2705 "ADValue": "CP0_VCS1", "Callouts": [ 2706 { 2707 "CalloutList": [ 2708 { "Priority": "high", "LocCode": "P0-C59" }, 2709 { "Priority": "medium", "LocCode": "P0-C61" }, 2710 { "Priority": "low", "LocCode": "P0" } 2711 ] 2712 } 2713 ] 2714 }, 2715 { 2716 "ADValue": "CP1_VCS0", "Callouts": [ 2717 { 2718 "CalloutList": [ 2719 { "Priority": "high", "LocCode": "P0-C12" }, 2720 { "Priority": "medium", "LocCode": "P0-C14" }, 2721 { "Priority": "low", "LocCode": "P0" } 2722 ] 2723 } 2724 ] 2725 }, 2726 { 2727 "ADValue": "CP1_VCS1", "Callouts": [ 2728 { 2729 "CalloutList": [ 2730 { "Priority": "high", "LocCode": "P0-C16" }, 2731 { "Priority": "medium", "LocCode": "P0-C14" }, 2732 { "Priority": "low", "LocCode": "P0" } 2733 ] 2734 } 2735 ] 2736 }, 2737 { 2738 "ADValue": "CP2_VCS0", "Callouts": [ 2739 { 2740 "CalloutList": [ 2741 { "Priority": "high", "LocCode": "P0-C17" }, 2742 { "Priority": "medium", "LocCode": "P0-C19" }, 2743 { "Priority": "low", "LocCode": "P0" } 2744 ] 2745 } 2746 ] 2747 }, 2748 { 2749 "ADValue": "CP2_VCS1", "Callouts": [ 2750 { 2751 "CalloutList": [ 2752 { "Priority": "high", "LocCode": "P0-C21" }, 2753 { "Priority": "medium", "LocCode": "P0-C19" }, 2754 { "Priority": "low", "LocCode": "P0" } 2755 ] 2756 } 2757 ] 2758 }, 2759 { 2760 "ADValue": "CP3_VCS0", "Callouts": [ 2761 { 2762 "CalloutList": [ 2763 { "Priority": "high", "LocCode": "P0-C58" }, 2764 { "Priority": "medium", "LocCode": "P0-C56" }, 2765 { "Priority": "low", "LocCode": "P0" } 2766 ] 2767 } 2768 ] 2769 }, 2770 { 2771 "ADValue": "CP3_VCS1", "Callouts": [ 2772 { 2773 "CalloutList": [ 2774 { "Priority": "high", "LocCode": "P0-C54" }, 2775 { "Priority": "medium", "LocCode": "P0-C56" }, 2776 { "Priority": "low", "LocCode": "P0" } 2777 ] 2778 } 2779 ] 2780 }, 2781 { 2782 "ADValue": "CP0_VDN", "Callouts": [ 2783 { 2784 "CalloutList": [ 2785 { "Priority": "high", "LocCode": "P0-C63" }, 2786 { "Priority": "medium", "LocCode": "P0-C61" }, 2787 { "Priority": "low", "LocCode": "P0" } 2788 ] 2789 } 2790 ] 2791 }, 2792 { 2793 "ADValue": "CP1_VDN", "Callouts": [ 2794 { 2795 "CalloutList": [ 2796 { "Priority": "high", "LocCode": "P0-C12" }, 2797 { "Priority": "medium", "LocCode": "P0-C14" }, 2798 { "Priority": "low", "LocCode": "P0" } 2799 ] 2800 } 2801 ] 2802 }, 2803 { 2804 "ADValue": "CP2_VDN", "Callouts": [ 2805 { 2806 "CalloutList": [ 2807 { "Priority": "high", "LocCode": "P0-C21" }, 2808 { "Priority": "medium", "LocCode": "P0-C19" }, 2809 { "Priority": "low", "LocCode": "P0" } 2810 ] 2811 } 2812 ] 2813 }, 2814 { 2815 "ADValue": "CP3_VDN", "Callouts": [ 2816 { 2817 "CalloutList": [ 2818 { "Priority": "high", "LocCode": "P0-C54" }, 2819 { "Priority": "medium", "LocCode": "P0-C56" }, 2820 { "Priority": "low", "LocCode": "P0" } 2821 ] 2822 } 2823 ] 2824 }, 2825 { 2826 "ADValue": "CP0_VIO", "Callouts": [ 2827 { 2828 "CalloutList": [ 2829 { "Priority": "high", "LocCode": "P0-C63" }, 2830 { "Priority": "medium", "LocCode": "P0-C61" }, 2831 { "Priority": "low", "LocCode": "P0" } 2832 ] 2833 } 2834 ] 2835 }, 2836 { 2837 "ADValue": "CP1_VIO", "Callouts": [ 2838 { 2839 "CalloutList": [ 2840 { "Priority": "high", "LocCode": "P0-C12" }, 2841 { "Priority": "medium", "LocCode": "P0-C14" }, 2842 { "Priority": "low", "LocCode": "P0" } 2843 ] 2844 } 2845 ] 2846 }, 2847 { 2848 "ADValue": "CP2_VIO", "Callouts": [ 2849 { 2850 "CalloutList": [ 2851 { "Priority": "high", "LocCode": "P0-C21" }, 2852 { "Priority": "medium", "LocCode": "P0-C19" }, 2853 { "Priority": "low", "LocCode": "P0" } 2854 ] 2855 } 2856 ] 2857 }, 2858 { 2859 "ADValue": "CP3_VIO", "Callouts": [ 2860 { 2861 "CalloutList": [ 2862 { "Priority": "high", "LocCode": "P0-C54" }, 2863 { "Priority": "medium", "LocCode": "P0-C56" }, 2864 { "Priority": "low", "LocCode": "P0" } 2865 ] 2866 } 2867 ] 2868 }, 2869 { 2870 "ADValue": "CP0_VPCIE", "Callouts": [ 2871 { 2872 "CalloutList": [ 2873 { "Priority": "high", "LocCode": "P0-C58" }, 2874 { "Priority": "medium", "LocCode": "P0-C61" }, 2875 { "Priority": "low", "LocCode": "P0" } 2876 ] 2877 } 2878 ] 2879 }, 2880 { 2881 "ADValue": "CP1_VPCIE", "Callouts": [ 2882 { 2883 "CalloutList": [ 2884 { "Priority": "high", "LocCode": "P0-C16" }, 2885 { "Priority": "medium", "LocCode": "P0-C14" }, 2886 { "Priority": "low", "LocCode": "P0" } 2887 ] 2888 } 2889 ] 2890 }, 2891 { 2892 "ADValue": "CP2_VPCIE", "Callouts": [ 2893 { 2894 "CalloutList": [ 2895 { "Priority": "high", "LocCode": "P0-C16" }, 2896 { "Priority": "medium", "LocCode": "P0-C19" }, 2897 { "Priority": "low", "LocCode": "P0" } 2898 ] 2899 } 2900 ] 2901 }, 2902 { 2903 "ADValue": "CP3_VPCIE", "Callouts": [ 2904 { 2905 "CalloutList": [ 2906 { "Priority": "high", "LocCode": "P0-C58" }, 2907 { "Priority": "medium", "LocCode": "P0-C56" }, 2908 { "Priority": "low", "LocCode": "P0" } 2909 ] 2910 } 2911 ] 2912 }, 2913 { 2914 "ADValue": "12.0VCS", "Callouts": [ 2915 { 2916 "CalloutList": [ 2917 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2918 ] 2919 } 2920 ] 2921 }, 2922 { 2923 "ADValue": "3.3VCS", "Callouts": [ 2924 { 2925 "CalloutList": [ 2926 { "Priority": "high", "LocCode": "P0" } 2927 ] 2928 } 2929 ] 2930 }, 2931 { 2932 "ADValue": "1.1V_Current", "Callouts": [ 2933 { 2934 "CalloutList": [ 2935 { "Priority": "high", "LocCode": "P0" } 2936 ] 2937 } 2938 ] 2939 }, 2940 { 2941 "ADValue": "5.0V_USB_Current", "Callouts": [ 2942 { 2943 "CalloutList": [ 2944 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 2945 { "Priority": "medium", "LocCode": "P0" } 2946 ] 2947 } 2948 ] 2949 }, 2950 { 2951 "ADValue": "5.0V_DASD_Current", "Callouts": [ 2952 { 2953 "CalloutList": [ 2954 { "Priority": "medium", "LocCode": "P1" }, 2955 { "Priority": "medium", "LocCode": "P2" }, 2956 { "Priority": "low", "LocCode": "P0" } 2957 ] 2958 } 2959 ] 2960 }, 2961 { 2962 "ADValue": "12.0VN", "Callouts": [ 2963 { 2964 "CalloutList": [ 2965 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2966 ] 2967 } 2968 ] 2969 }, 2970 { 2971 "ADValue": "12.0VP", "Callouts": [ 2972 { 2973 "CalloutList": [ 2974 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2975 ] 2976 } 2977 ] 2978 }, 2979 { 2980 "ADValue": "12.0VQ", "Callouts": [ 2981 { 2982 "CalloutList": [ 2983 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2984 ] 2985 } 2986 ] 2987 }, 2988 { 2989 "ADValue": "12.0VR", "Callouts": [ 2990 { 2991 "CalloutList": [ 2992 { "Priority": "high", "SymbolicFRU": "pgood_part" } 2993 ] 2994 } 2995 ] 2996 }, 2997 { 2998 "ADValue": "ThermalDiode1", "Callouts": [ 2999 { 3000 "CalloutList": [ 3001 { "Priority": "high", "LocCode": "P0" } 3002 ] 3003 } 3004 ] 3005 }, 3006 { 3007 "ADValue": "ThermalDiode2", "Callouts": [ 3008 { 3009 "CalloutList": [ 3010 { "Priority": "high", "LocCode": "P0" } 3011 ] 3012 } 3013 ] 3014 }, 3015 { 3016 "ADValue": "ThermalDiode3", "Callouts": [ 3017 { 3018 "CalloutList": [ 3019 { "Priority": "high", "LocCode": "P0" } 3020 ] 3021 } 3022 ] 3023 }, 3024 { 3025 "ADValue": "ThermalDiode4", "Callouts": [ 3026 { 3027 "CalloutList": [ 3028 { "Priority": "high", "LocCode": "P0" } 3029 ] 3030 } 3031 ] 3032 }, 3033 { 3034 "ADValue": "VDN_DCM0", "Callouts": [ 3035 { 3036 "CalloutList": [ 3037 { "Priority": "high", "LocCode": "P0-C14" }, 3038 { "Priority": "medium", "LocCode": "P0-C15" }, 3039 { "Priority": "low", "LocCode": "P0" } 3040 ] 3041 } 3042 ] 3043 }, 3044 { 3045 "ADValue": "VDN_DCM1", "Callouts": [ 3046 { 3047 "CalloutList": [ 3048 { "Priority": "high", "LocCode": "P0-C23" }, 3049 { "Priority": "medium", "LocCode": "P0-C24" }, 3050 { "Priority": "low", "LocCode": "P0" } 3051 ] 3052 } 3053 ] 3054 }, 3055 { 3056 "ADValue": "VCS_DCM0", "Callouts": [ 3057 { 3058 "CalloutList": [ 3059 { "Priority": "high", "LocCode": "P0-C14" }, 3060 { "Priority": "medium", "LocCode": "P0-C15" }, 3061 { "Priority": "low", "LocCode": "P0" } 3062 ] 3063 } 3064 ] 3065 }, 3066 { 3067 "ADValue": "VCS_DCM1", "Callouts": [ 3068 { 3069 "CalloutList": [ 3070 { "Priority": "high", "LocCode": "P0-C23" }, 3071 { "Priority": "medium", "LocCode": "P0-C24" }, 3072 { "Priority": "low", "LocCode": "P0" } 3073 ] 3074 } 3075 ] 3076 }, 3077 { 3078 "ADValue": "VIO_DCM0", "Callouts": [ 3079 { 3080 "CalloutList": [ 3081 { "Priority": "high", "LocCode": "P0-C14" }, 3082 { "Priority": "medium", "LocCode": "P0-C15" }, 3083 { "Priority": "low", "LocCode": "P0" } 3084 ] 3085 } 3086 ] 3087 }, 3088 { 3089 "ADValue": "VIO_DCM1", "Callouts": [ 3090 { 3091 "CalloutList": [ 3092 { "Priority": "high", "LocCode": "P0-C23" }, 3093 { "Priority": "medium", "LocCode": "P0-C24" }, 3094 { "Priority": "low", "LocCode": "P0" } 3095 ] 3096 } 3097 ] 3098 }, 3099 { 3100 "ADValue": "VPCIE_DCM0", "Callouts": [ 3101 { 3102 "CalloutList": [ 3103 { "Priority": "high", "LocCode": "P0-C14" }, 3104 { "Priority": "medium", "LocCode": "P0-C15" }, 3105 { "Priority": "low", "LocCode": "P0" } 3106 ] 3107 } 3108 ] 3109 }, 3110 { 3111 "ADValue": "VPCIE_DCM1", "Callouts": [ 3112 { 3113 "CalloutList": [ 3114 { "Priority": "high", "LocCode": "P0-C23" }, 3115 { "Priority": "medium", "LocCode": "P0-C24" }, 3116 { "Priority": "low", "LocCode": "P0" } 3117 ] 3118 } 3119 ] 3120 } 3121 ] 3122 }, 3123 3124 "Documentation": { 3125 "Description": "The power sequencer chip detected a voltage fault", 3126 "Message": "The power sequencer chip detected a voltage fault", 3127 "Notes": [ 3128 ] 3129 } 3130 }, 3131 3132 { 3133 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 3134 "Subsystem": "power", 3135 "Severity": "predictive_redundancy_loss", 3136 "ComponentID": "0x2700", 3137 3138 "SRC": { 3139 "Type": "11", 3140 "ReasonCode": "0x2700", 3141 "Words6To9": {} 3142 }, 3143 3144 "Documentation": { 3145 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 3146 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 3147 "Notes": [ 3148 "CALLOUT_INVENTORY_PATH should be specified in the ", 3149 "AdditionalData property of the event log so that ", 3150 "the device is called out but not the communication path." 3151 ] 3152 } 3153 }, 3154 3155 { 3156 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 3157 "Subsystem": "power", 3158 "Severity": "non_error", 3159 "MfgSeverity": "predictive_redundancy_loss", 3160 "ActionFlags": ["report"], 3161 "MfgActionFlags": ["service_action", "report", "call_home"], 3162 "ComponentID": "0x2700", 3163 3164 "SRC": { 3165 "Type": "11", 3166 "ReasonCode": "0x2701", 3167 "Words6To9": {} 3168 }, 3169 3170 "Documentation": { 3171 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 3172 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 3173 "Notes": [ 3174 "CALLOUT_INVENTORY_PATH should be specified in the ", 3175 "AdditionalData property of the event log so that ", 3176 "the device is called out but not the communication path." 3177 ] 3178 } 3179 }, 3180 3181 { 3182 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 3183 "Subsystem": "power", 3184 "ComponentID": "0x2700", 3185 3186 "SRC": { 3187 "Type": "11", 3188 "ReasonCode": "0x2900", 3189 "Words6To9": {} 3190 }, 3191 3192 "Documentation": { 3193 "Description": "A write verification error occurred on a device", 3194 "Message": "A write verification error occurred on a device", 3195 "Notes": [ 3196 "This error occurs when a device register is written, ", 3197 "read back, and the two values do not match. This is ", 3198 "also called a read-back error. The device should be ", 3199 "identified using the CALLOUT_DEVICE_PATH or ", 3200 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 3201 "AdditionalData property of the event log. This will ", 3202 "cause the device and the hardware in the communication ", 3203 "path to be called out." 3204 ] 3205 } 3206 }, 3207 3208 { 3209 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Discharging", 3210 "Subsystem": "power", 3211 "Severity": "non_error", 3212 "ActionFlags": ["report"], 3213 "ComponentID": "0x2700", 3214 3215 "SRC": { 3216 "Type": "11", 3217 "ReasonCode": "0x4201", 3218 "Words6To9": {} 3219 }, 3220 3221 "Documentation": { 3222 "Description": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 3223 "Message": "The Uninterruptible Power Supply (UPS) battery is discharging and providing power to the system due to a utility failure", 3224 "Notes": [ 3225 ] 3226 } 3227 }, 3228 3229 { 3230 "Name": "xyz.openbmc_project.Power.UPS.Error.Battery.Low", 3231 "Subsystem": "power", 3232 "Severity": "non_error", 3233 "ActionFlags": ["report"], 3234 "ComponentID": "0x2700", 3235 3236 "SRC": { 3237 "Type": "11", 3238 "ReasonCode": "0x4203", 3239 "Words6To9": {} 3240 }, 3241 3242 "Documentation": { 3243 "Description": "The Uninterruptible Power Supply (UPS) battery level is low", 3244 "Message": "The Uninterruptible Power Supply (UPS) battery level is low", 3245 "Notes": [ 3246 ] 3247 } 3248 }, 3249 3250 { 3251 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 3252 "Subsystem": "power", 3253 "ComponentID": "0x2700", 3254 3255 "SRC": { 3256 "Type": "11", 3257 "ReasonCode": "0xA013", 3258 "Words6To9": {} 3259 }, 3260 3261 "Callouts": [ 3262 { 3263 "CalloutList": [ 3264 { "Priority": "high", "Procedure": "bmc_code" } 3265 ] 3266 } 3267 ], 3268 3269 "Documentation": { 3270 "Description": "A regulators configuration file error occurred", 3271 "Message": "A regulators configuration file error occurred", 3272 "Notes": [ 3273 "The regulators configuration file could not be found, ", 3274 "could not be read, or had invalid contents." 3275 ] 3276 } 3277 }, 3278 3279 { 3280 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 3281 "Subsystem": "power", 3282 "Severity": "critical_system_term", 3283 "ComponentID": "0x2700", 3284 3285 "SRC": { 3286 "Type": "11", 3287 "ReasonCode": "0xA014", 3288 "Words6To9": {} 3289 }, 3290 3291 "Callouts": [ 3292 { 3293 "CalloutList": [ 3294 { "Priority": "high", "Procedure": "bmc_code" } 3295 ] 3296 } 3297 ], 3298 3299 "Documentation": { 3300 "Description": "A critical regulators configuration file error occurred", 3301 "Message": "A critical regulators configuration file error occurred", 3302 "Notes": [ 3303 "The regulators configuration file could not be found, ", 3304 "could not be read, or had invalid contents. As a result ", 3305 "voltage regulators could not be configured, and the ", 3306 "chassis could not be powered on." 3307 ] 3308 } 3309 }, 3310 3311 { 3312 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 3313 "Subsystem": "power_sequencer", 3314 "ComponentID": "0x2700", 3315 3316 "SRC": { 3317 "Type": "11", 3318 "ReasonCode": "0xD000", 3319 "Words6To9": {} 3320 }, 3321 3322 "Callouts": [ 3323 { 3324 "CalloutList": [ 3325 { "Priority": "high", "LocCode": "P0" } 3326 ] 3327 } 3328 ], 3329 3330 "Documentation": { 3331 "Description": "The power sequencer chip detected a fault", 3332 "Message": "The power sequencer chip detected a fault", 3333 "Notes": [ 3334 ] 3335 } 3336 }, 3337 3338 { 3339 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 3340 "Subsystem": "power_sequencer", 3341 "ComponentID": "0x2700", 3342 "Severity": "critical", 3343 3344 "SRC": { 3345 "Type": "11", 3346 "ReasonCode": "0xD002", 3347 "Words6To9": {} 3348 }, 3349 3350 "Callouts": [ 3351 { 3352 "CalloutList": [ 3353 { "Priority": "high", "LocCode": "P0" } 3354 ] 3355 } 3356 ], 3357 3358 "Documentation": { 3359 "Description": "System power failed to turn on within timeout period", 3360 "Message": "System power failed to turn on within timeout period", 3361 "Notes": [ 3362 ] 3363 } 3364 }, 3365 3366 { 3367 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 3368 "Subsystem": "power_sequencer", 3369 "ComponentID": "0x2700", 3370 "Severity": "critical", 3371 3372 "SRC": { 3373 "Type": "11", 3374 "ReasonCode": "0xD008", 3375 "Words6To9": {} 3376 }, 3377 3378 "Callouts": [ 3379 { 3380 "CalloutList": [ 3381 { "Priority": "high", "LocCode": "P0" } 3382 ] 3383 } 3384 ], 3385 3386 "Documentation": { 3387 "Description": "System power failed to turn off within timeout period", 3388 "Message": "System power failed to turn off within timeout period", 3389 "Notes": [ 3390 ] 3391 } 3392 }, 3393 3394 { 3395 "Name": "xyz.openbmc_project.Power.Error.Internal", 3396 "Subsystem": "power", 3397 "ComponentID": "0x2700", 3398 3399 "SRC": { 3400 "Type": "11", 3401 "ReasonCode": "0xE000", 3402 "Words6To9": {} 3403 }, 3404 3405 "Callouts": [ 3406 { 3407 "CalloutList": [ 3408 { "Priority": "high", "Procedure": "bmc_code" } 3409 ] 3410 } 3411 ], 3412 3413 "Documentation": { 3414 "Description": "An internal firmware error occurred", 3415 "Message": "An internal firmware error occurred", 3416 "Notes": [ 3417 "The error details must be provided in the AdditionalData ", 3418 "property of the event log." 3419 ] 3420 } 3421 }, 3422 3423 { 3424 "Name": "xyz.openbmc_project.Power.Error.I2C", 3425 "Subsystem": "cec_i2c", 3426 "ComponentID": "0x2700", 3427 3428 "SRC": { 3429 "Type": "11", 3430 "ReasonCode": "0xE100", 3431 "Words6To9": {} 3432 }, 3433 3434 "Documentation": { 3435 "Description": "An I2C error occurred communicating with a device", 3436 "Message": "An I2C error occurred communicating with a device", 3437 "Notes": [ 3438 "The device should be identified using the ", 3439 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 3440 "keywords in the AdditionalData property of the event ", 3441 "log. This will cause the device and the hardware in the ", 3442 "communication path to be called out." 3443 ] 3444 } 3445 }, 3446 3447 { 3448 "Name": "xyz.openbmc_project.Power.Error.PMBus", 3449 "Subsystem": "power", 3450 "ComponentID": "0x2700", 3451 3452 "SRC": { 3453 "Type": "11", 3454 "ReasonCode": "0xE200", 3455 "Words6To9": {} 3456 }, 3457 3458 "Documentation": { 3459 "Description": "A PMBus error occurred on a device", 3460 "Message": "A PMBus error occurred on a device", 3461 "Notes": [ 3462 "This error occurs when the I2C communication was ", 3463 "successful, but the PMBus value read is invalid or ", 3464 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 3465 "in the AdditionalData property of the event log so that ", 3466 "the device is called out but not the communication path." 3467 ] 3468 } 3469 }, 3470 3471 { 3472 "Name": "xyz.openbmc_project.Power.Error.DBus", 3473 "Subsystem": "power", 3474 "ComponentID": "0x2700", 3475 3476 "SRC": { 3477 "Type": "11", 3478 "ReasonCode": "0xE300", 3479 "Words6To9": {} 3480 }, 3481 3482 "Callouts": [ 3483 { 3484 "CalloutList": [ 3485 { "Priority": "high", "Procedure": "bmc_code" } 3486 ] 3487 } 3488 ], 3489 3490 "Documentation": { 3491 "Description": "A firmware inter-process communication (D-Bus) error occurred", 3492 "Message": "A firmware inter-process communication (D-Bus) error occurred" 3493 } 3494 }, 3495 3496 { 3497 "Name": "xyz.openbmc_project.Fan.Error.Fault", 3498 "Subsystem": "power_fans", 3499 "ComponentID": "0x2800", 3500 3501 "SRC": { 3502 "Type": "11", 3503 "ReasonCode": "0x76F0", 3504 "Words6To9": {} 3505 }, 3506 3507 "Documentation": { 3508 "Description": "Fan rotor fault", 3509 "Message": "Fan rotor fault", 3510 "Notes": [ 3511 "This error occurs when a fan rotor has been faulted for a ", 3512 "certain amount of time. The callout is the fan which is ", 3513 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 3514 "passed in during creation and will be either informational ", 3515 "or unrecoverable. The action flags use the defaults and ", 3516 "vary based on the severity." 3517 ] 3518 } 3519 }, 3520 3521 { 3522 "Name": "xyz.openbmc_project.Fan.Error.Missing", 3523 "Subsystem": "power_fans", 3524 "ComponentID": "0x2800", 3525 "Severity": "unrecoverable_redundancy_loss", 3526 "ActionFlags": ["service_action", "report", "call_home"], 3527 3528 "SRC": { 3529 "Type": "11", 3530 "ReasonCode": "0x76F1", 3531 "Words6To9": {} 3532 }, 3533 3534 "Callouts": [ 3535 { 3536 "System": "ibm,rainier", 3537 "CalloutList": [ 3538 { 3539 "Priority": "high", 3540 "SymbolicFRUTrusted": "air_mover", 3541 "UseInventoryLocCode": true 3542 }, 3543 { 3544 "Priority": "low", 3545 "LocCode": "P0" 3546 } 3547 ] 3548 }, 3549 { 3550 "System": "ibm,everest", 3551 "CalloutList": [ 3552 { 3553 "Priority": "high", 3554 "SymbolicFRUTrusted": "air_mover", 3555 "UseInventoryLocCode": true 3556 }, 3557 { 3558 "Priority": "low", 3559 "LocCode": "P1" 3560 } 3561 ] 3562 } 3563 ], 3564 3565 "Documentation": { 3566 "Description": "A fan is missing", 3567 "Message": "A fan is missing", 3568 "Notes": [ 3569 "This error occurs when a fan has been missing for a ", 3570 "certain amount of time. The first callout is the ", 3571 "symbolic FRU AIR_MOVR that has the trusted fan location ", 3572 "code, which it gets using the passed in ", 3573 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 3574 "where the controller and GPIO expander are." 3575 ] 3576 } 3577 }, 3578 3579 { 3580 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 3581 "ComponentID": "0x2800", 3582 "Subsystem": "power_fans", 3583 "Severity": "non_error", 3584 "ActionFlags": ["report"], 3585 "MfgSeverity": "predictive", 3586 "MfgActionFlags": ["service_action", "report"], 3587 3588 "SRC": { 3589 "Type": "11", 3590 "ReasonCode": "0x76F2", 3591 "Words6To9": {} 3592 }, 3593 3594 "Callouts": [ 3595 { 3596 "System": "ibm,rainier", 3597 "CalloutList": [ 3598 {"Priority": "medium", "LocCode": "P0"} 3599 ] 3600 }, 3601 { 3602 "System": "ibm,everest", 3603 "CalloutList": [ 3604 {"Priority": "medium", "LocCode": "P1"} 3605 ] 3606 } 3607 ], 3608 3609 "Documentation": { 3610 "Description": "Presence detect methods for the same fan disagree", 3611 "Message": "Presence detect methods for the same fan disagree", 3612 "Notes": [ 3613 "This error occurs when there is more than one way to detect", 3614 "fan presence, and they don't all agree. For example, the", 3615 "GPIO says a fan isn't present, but the tach readings are", 3616 "nonzero. This is informational, unless in manufacturing.", 3617 "The fan FRU is passed in as a high priority callout.", 3618 "The FRU the GPIO source is on is called out medium." 3619 ] 3620 } 3621 }, 3622 3623 { 3624 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 3625 "ComponentID": "0x2800", 3626 "Subsystem": "power_fans", 3627 "Severity": "critical_system_term", 3628 "ActionFlags": ["service_action", "report", "call_home"], 3629 3630 "SRC": { 3631 "Type": "11", 3632 "ReasonCode": "0x76F3", 3633 "Words6To9": {} 3634 }, 3635 3636 "Callouts": [ 3637 { 3638 "System": "ibm,rainier", 3639 "CalloutList": [ 3640 {"Priority": "high", "LocCode": "P0-C5"}, 3641 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 3642 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 3643 {"Priority": "low", "LocCode": "P0"} 3644 ] 3645 }, 3646 { 3647 "System": "ibm,everest", 3648 "CalloutList": [ 3649 {"Priority": "high", "LocCode": "P0-C0"}, 3650 {"Priority": "medium", "LocCode": "P1"}, 3651 {"Priority": "low", "LocCode": "P0"} 3652 ] 3653 } 3654 ], 3655 3656 "Documentation": { 3657 "Description": "The fan controller device is offline", 3658 "Message": "The fan controller is offline. The system must be powered off.", 3659 "Notes": [ 3660 "The device that controls the fans is offline so the fan", 3661 "targets and speeds are unknown. The system will be shut", 3662 "down to preserve thermal safety. There may be an I2C", 3663 "or power problem with the device." 3664 ] 3665 } 3666 }, 3667 3668 { 3669 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 3670 "Subsystem": "power_fans", 3671 "ComponentID": "0x2800", 3672 "Severity": "unrecoverable_redundancy_loss", 3673 "ActionFlags": ["service_action", "report", "call_home"], 3674 3675 "SRC": { 3676 "Type": "11", 3677 "ReasonCode": "0x76F4", 3678 "Words6To9": {} 3679 }, 3680 3681 "Callouts": [ 3682 { 3683 "System" : "ibm,rainier", 3684 "CalloutList": [ 3685 {"Priority": "high", "LocCode": "P0-C5"}, 3686 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 3687 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 3688 {"Priority": "low", "LocCode": "P0"} 3689 ] 3690 }, 3691 { 3692 "System" : "ibm,everest", 3693 "CalloutList": [ 3694 {"Priority": "high", "LocCode": "P0-C0"}, 3695 {"Priority": "medium", "LocCode": "P1"}, 3696 {"Priority": "low", "LocCode": "P0"} 3697 ] 3698 } 3699 ], 3700 3701 "Documentation": { 3702 "Description": "Fan GPIO sensors not present", 3703 "Message": "Fan GPIO sensors not present", 3704 "Notes": [ 3705 "The device that reports fan presence is not functioning." 3706 ] 3707 } 3708 }, 3709 3710 { 3711 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 3712 "Subsystem": "power", 3713 "ComponentID": "0x2800", 3714 "Severity": "predictive", 3715 "ActionFlags": ["service_action", "report"], 3716 3717 "SRC": { 3718 "ReasonCode": "0x2801", 3719 "Words6To9": {} 3720 }, 3721 3722 "CalloutsUsingAD": { 3723 "ADName": "SENSOR_NAME", 3724 "CalloutsWithTheirADValues": [ 3725 { 3726 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3727 "Callouts": [ 3728 { 3729 "CalloutList": [ 3730 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3731 ] 3732 } 3733 ] 3734 } 3735 ] 3736 }, 3737 3738 "Documentation": { 3739 "Description": "A temperature sensor exceeded its performance loss threshold.", 3740 "Message": "A temperature sensor exceeded its performance loss threshold.", 3741 "Notes": [ 3742 "A temperature sensor crossed its performance loss threshold value", 3743 "If it is the ambient sensor, then a symbolic FRU will be added.", 3744 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3745 "a FRU callout." 3746 ] 3747 } 3748 }, 3749 3750 { 3751 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 3752 "Subsystem": "power", 3753 "ComponentID": "0x2800", 3754 "Severity": "non_error", 3755 "ActionFlags": ["report"], 3756 "EventType": "env_normal", 3757 3758 "SRC": { 3759 "ReasonCode": "0x2802", 3760 "Words6To9": {} 3761 }, 3762 3763 "CalloutsUsingAD": { 3764 "ADName": "SENSOR_NAME", 3765 "CalloutsWithTheirADValues": [ 3766 { 3767 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3768 "Callouts": [ 3769 { 3770 "CalloutList": [ 3771 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3772 ] 3773 } 3774 ] 3775 } 3776 ] 3777 }, 3778 3779 "Documentation": { 3780 "Description": "A temperature sensor is under its performance loss threshold.", 3781 "Message": "A temperature sensor is under its performance loss threshold.", 3782 "Notes": [ 3783 "A temperature sensor crossed under its performance loss threshold value", 3784 "If it is the ambient sensor, then a symbolic FRU will be added." 3785 ] 3786 } 3787 }, 3788 3789 { 3790 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 3791 "Subsystem": "power", 3792 "ComponentID": "0x2800", 3793 "Severity": "predictive", 3794 "ActionFlags": ["service_action", "report"], 3795 3796 "SRC": { 3797 "ReasonCode": "0x2803", 3798 "Words6To9": {} 3799 }, 3800 3801 "CalloutsUsingAD": { 3802 "ADName": "SENSOR_NAME", 3803 "CalloutsWithTheirADValues": [ 3804 { 3805 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3806 "Callouts": [ 3807 { 3808 "CalloutList": [ 3809 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3810 ] 3811 } 3812 ] 3813 } 3814 ] 3815 }, 3816 3817 "Documentation": { 3818 "Description": "A temperature sensor exceeded its warning threshold.", 3819 "Message": "A temperature sensor exceeded its warning threshold.", 3820 "Notes": [ 3821 "A temperature sensor crossed its warning threshold value", 3822 "If it is the ambient sensor, then a symbolic FRU will be added.", 3823 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3824 "a FRU callout." 3825 ] 3826 } 3827 }, 3828 3829 { 3830 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 3831 "Subsystem": "power", 3832 "ComponentID": "0x2800", 3833 "Severity": "non_error", 3834 "ActionFlags": ["report"], 3835 "EventType": "env_normal", 3836 3837 "SRC": { 3838 "ReasonCode": "0x2804", 3839 "Words6To9": {} 3840 }, 3841 3842 "CalloutsUsingAD": { 3843 "ADName": "SENSOR_NAME", 3844 "CalloutsWithTheirADValues": [ 3845 { 3846 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3847 "Callouts": [ 3848 { 3849 "CalloutList": [ 3850 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3851 ] 3852 } 3853 ] 3854 } 3855 ] 3856 }, 3857 3858 "Documentation": { 3859 "Description": "A temperature sensor is under its warning threshold.", 3860 "Message": "A temperature sensor is under its warning threshold.", 3861 "Notes": [ 3862 "A temperature sensor crossed under its warning threshold value", 3863 "If it is the ambient sensor, then a symbolic FRU will be added." 3864 ] 3865 } 3866 }, 3867 3868 { 3869 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 3870 "Subsystem": "power", 3871 "ComponentID": "0x2800", 3872 "Severity": "predictive", 3873 "ActionFlags": ["service_action", "report"], 3874 3875 "SRC": { 3876 "ReasonCode": "0x2805", 3877 "Words6To9": {} 3878 }, 3879 3880 "CalloutsUsingAD": { 3881 "ADName": "SENSOR_NAME", 3882 "CalloutsWithTheirADValues": [ 3883 { 3884 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3885 "Callouts": [ 3886 { 3887 "CalloutList": [ 3888 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 3889 ] 3890 } 3891 ] 3892 } 3893 ] 3894 }, 3895 3896 "Documentation": { 3897 "Description": "A temperature sensor exceeded its critical threshold.", 3898 "Message": "A temperature sensor exceeded its critical threshold.", 3899 "Notes": [ 3900 "A temperature sensor crossed its critical threshold value", 3901 "If it is the ambient sensor, then a symbolic FRU will be added.", 3902 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 3903 "a FRU callout." 3904 ] 3905 } 3906 }, 3907 3908 { 3909 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 3910 "Subsystem": "power", 3911 "ComponentID": "0x2800", 3912 "Severity": "non_error", 3913 "ActionFlags": ["report"], 3914 "EventType": "env_normal", 3915 3916 "SRC": { 3917 "ReasonCode": "0x2806", 3918 "Words6To9": {} 3919 }, 3920 3921 "CalloutsUsingAD": { 3922 "ADName": "SENSOR_NAME", 3923 "CalloutsWithTheirADValues": [ 3924 { 3925 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 3926 "Callouts": [ 3927 { 3928 "CalloutList": [ 3929 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 3930 ] 3931 } 3932 ] 3933 } 3934 ] 3935 }, 3936 3937 "Documentation": { 3938 "Description": "A temperature sensor is under its critical threshold.", 3939 "Message": "A temperature sensor is under its critical threshold.", 3940 "Notes": [ 3941 "A temperature sensor crossed under its critical threshold value", 3942 "If it is the ambient sensor, then a symbolic FRU will be added." 3943 ] 3944 } 3945 }, 3946 3947 { 3948 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 3949 "Subsystem": "power", 3950 "ComponentID": "0x2800", 3951 "Severity": "predictive", 3952 "ActionFlags": ["service_action", "report"], 3953 3954 "SRC": { 3955 "ReasonCode": "0x2807", 3956 "Words6To9": {} 3957 }, 3958 3959 "Callouts": [ 3960 { 3961 "CalloutList": [ 3962 { 3963 "Priority": "high", 3964 "SymbolicFRU": "ambient_temp" 3965 } 3966 ] 3967 } 3968 ], 3969 3970 "Documentation": { 3971 "Description": "The ambient temperature passed the EPOW3 limit.", 3972 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 3973 "Notes": [ 3974 "This error occurs when the ambient temperature surpassed", 3975 "the EPOW3 shutdown limit." 3976 ] 3977 } 3978 }, 3979 3980 { 3981 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 3982 "Subsystem": "power", 3983 "ComponentID": "0x2800", 3984 "Severity": "non_error", 3985 "ActionFlags": ["report"], 3986 "EventType": "env_normal", 3987 3988 "SRC": { 3989 "ReasonCode": "0x2808", 3990 "Words6To9": {} 3991 }, 3992 3993 "Callouts": [ 3994 { 3995 "CalloutList": [ 3996 { 3997 "Priority": "high", 3998 "SymbolicFRU": "ambient_temp_back" 3999 } 4000 ] 4001 } 4002 ], 4003 4004 "Documentation": { 4005 "Description": "The ambient temperature is back under the EPOW3 limit.", 4006 "Message": "The ambient temperature is back under the EPOW3 limit." 4007 } 4008 }, 4009 4010 { 4011 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 4012 "Subsystem": "power", 4013 "ComponentID": "0x2800", 4014 "ActionFlags": ["service_action", "report"], 4015 4016 "SRC": { 4017 "ReasonCode": "0x2809", 4018 "Words6To9": {} 4019 }, 4020 4021 "Callouts": [ 4022 { 4023 "CalloutList": [ 4024 { 4025 "Priority": "high", 4026 "SymbolicFRU": "ambient_temp" 4027 } 4028 ] 4029 } 4030 ], 4031 4032 "Documentation": { 4033 "Description": "The ambient temperature passed the EPOW4 limit.", 4034 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 4035 "Notes": [ 4036 "This error occurs when the ambient temperature surpassed", 4037 "the EPOW4 shutdown limit." 4038 ] 4039 } 4040 }, 4041 4042 { 4043 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 4044 "Subsystem": "ext_env", 4045 "ComponentID": "0x2800", 4046 "Severity": "predictive", 4047 "ActionFlags": ["service_action", "report"], 4048 4049 "SRC": { 4050 "ReasonCode": "0x280A", 4051 "Words6To9": {} 4052 }, 4053 4054 "CalloutsUsingAD": { 4055 "ADName": "SENSOR_NAME", 4056 "CalloutsWithTheirADValues": [ 4057 { 4058 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 4059 "Callouts": [ 4060 { 4061 "CalloutList": [ 4062 { "Priority": "high", "SymbolicFRU": "altitude" } 4063 ] 4064 } 4065 ] 4066 } 4067 ] 4068 }, 4069 4070 "Documentation": { 4071 "Description": "An altitude sensor exceeded its warning threshold.", 4072 "Message": "An altitude sensor exceeded its warning threshold.", 4073 "Notes": [ 4074 "The virtual altitude sensor crossed its warning threshold value", 4075 " and a symbolic FRU will be added." 4076 ] 4077 } 4078 }, 4079 4080 { 4081 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 4082 "Subsystem": "ext_env", 4083 "ComponentID": "0x2800", 4084 "Severity": "non_error", 4085 "ActionFlags": ["report"], 4086 "EventType": "env_normal", 4087 4088 "SRC": { 4089 "ReasonCode": "0x280B", 4090 "Words6To9": {} 4091 }, 4092 4093 "Documentation": { 4094 "Description": "An altitude sensor is under its warning threshold.", 4095 "Message": "An altitude sensor is under its warning threshold.", 4096 "Notes": [ 4097 "The virtual altitude sensor is under its warning threshold value", 4098 " and a symbolic FRU will be added." 4099 ] 4100 } 4101 }, 4102 4103 { 4104 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 4105 "Subsystem": "cec_tod", 4106 "ComponentID": "0x2800", 4107 "Severity": "predictive", 4108 "ActionFlags": ["service_action", "report"], 4109 4110 "SRC": { 4111 "ReasonCode": "0x280C", 4112 "Words6To9": {} 4113 }, 4114 4115 "Documentation": { 4116 "Description": "A voltage sensor went below its critical low threshold.", 4117 "Message": "A voltage sensor went below its critical low threshold." 4118 } 4119 }, 4120 4121 { 4122 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 4123 "Subsystem": "cec_tod", 4124 "ComponentID": "0x2800", 4125 "Severity": "non_error", 4126 "ActionFlags": ["report"], 4127 4128 "SRC": { 4129 "ReasonCode": "0x280D", 4130 "Words6To9": {} 4131 }, 4132 4133 "Documentation": { 4134 "Description": "A voltage sensor is over its critical low threshold.", 4135 "Message": "A voltage sensor is over its critical low threshold." 4136 } 4137 }, 4138 4139 { 4140 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLow", 4141 "Subsystem": "power", 4142 "ComponentID": "0x2800", 4143 "Severity": "predictive", 4144 "ActionFlags": ["service_action", "report"], 4145 4146 "SRC": { 4147 "ReasonCode": "0x280E", 4148 "Words6To9": {} 4149 }, 4150 4151 "Documentation": { 4152 "Description": "A temperature sensor is under its low warning threshold.", 4153 "Message": "A temperature sensor is under its low warning threshold.", 4154 "Notes": [ 4155 "A temperature sensor crossed its low warning threshold value", 4156 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 4157 ] 4158 } 4159 }, 4160 4161 { 4162 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLowClear", 4163 "Subsystem": "power", 4164 "ComponentID": "0x2800", 4165 "Severity": "non_error", 4166 "ActionFlags": ["report"], 4167 "EventType": "env_normal", 4168 4169 "SRC": { 4170 "ReasonCode": "0x280F", 4171 "Words6To9": {} 4172 }, 4173 4174 "Documentation": { 4175 "Description": "A temperature sensor is above its low warning threshold.", 4176 "Message": "A temperature sensor is above its low warning threshold.", 4177 "Notes": [ 4178 "A temperature sensor crossed above its low warning threshold value." 4179 ] 4180 } 4181 }, 4182 4183 { 4184 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLow", 4185 "Subsystem": "power", 4186 "ComponentID": "0x2800", 4187 "Severity": "predictive", 4188 "ActionFlags": ["service_action", "report"], 4189 4190 "SRC": { 4191 "ReasonCode": "0x2810", 4192 "Words6To9": {} 4193 }, 4194 4195 "Documentation": { 4196 "Description": "A temperature sensor is under its low critical threshold.", 4197 "Message": "A temperature sensor is under its low critical threshold.", 4198 "Notes": [ 4199 "A temperature sensor crossed its low critical threshold value", 4200 "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout." 4201 ] 4202 } 4203 }, 4204 4205 { 4206 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLowClear", 4207 "Subsystem": "power", 4208 "ComponentID": "0x2800", 4209 "Severity": "non_error", 4210 "ActionFlags": ["report"], 4211 "EventType": "env_normal", 4212 4213 "SRC": { 4214 "ReasonCode": "0x2811", 4215 "Words6To9": {} 4216 }, 4217 4218 "Documentation": { 4219 "Description": "A temperature sensor is over its low critical threshold.", 4220 "Message": "A temperature sensor is over its low critical threshold.", 4221 "Notes": [ 4222 "A temperature sensor crossed above its critical threshold value" 4223 ] 4224 } 4225 }, 4226 4227 { 4228 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 4229 "Subsystem": "cec_vpd", 4230 "ComponentID": "0x4000", 4231 4232 "SRC": { 4233 "ReasonCode": "0x4000", 4234 "Words6To9": 4235 { 4236 "6": 4237 { 4238 "Description": "Errno of the failure.", 4239 "AdditionalDataPropSource": "CALLOUT_ERRNO" 4240 } 4241 } 4242 }, 4243 4244 "Documentation": { 4245 "Description": "A path access error occurred", 4246 "Message": "An EEPROM path access error occurred.", 4247 "Notes": [ 4248 "This error occurs when parser is unable to access", 4249 "EEPROM path. Errno and device path are captured as", 4250 "additional data." 4251 ] 4252 } 4253 }, 4254 4255 { 4256 "Name": "com.ibm.VPD.Error.InvalidVPD", 4257 "Subsystem": "cec_vpd", 4258 "ComponentID": "0x4000", 4259 4260 "SRC": { 4261 "ReasonCode": "0x4001", 4262 "Words6To9": 4263 { 4264 } 4265 }, 4266 4267 "Documentation": { 4268 "Description": "Invalid VPD data.", 4269 "Message": "A VPD data exception occurred.", 4270 "Notes": [ 4271 "This error occurs when VPD data is found to be", 4272 "invalid. This can be when VPD file is missing out", 4273 "mandatory records.Inventory path is captured in", 4274 "additional data." 4275 ] 4276 } 4277 }, 4278 4279 { 4280 "Name": "com.ibm.VPD.Error.EccCheckFailed", 4281 "Subsystem": "cec_vpd", 4282 "ComponentID": "0x4000", 4283 4284 "SRC": { 4285 "ReasonCode": "0x4002", 4286 "Words6To9": 4287 { 4288 } 4289 }, 4290 4291 "Documentation": { 4292 "Description": "Invalid VPD ecc data.", 4293 "Message": "A VPD ecc exception occurred.", 4294 "Notes": [ 4295 "This error occurs when VPD ecc check fails for the FRU.", 4296 "Inventory path for the failed FRU is captured in additonal", 4297 "data." 4298 ] 4299 } 4300 }, 4301 4302 { 4303 "Name": "com.ibm.VPD.Error.InvalidJson", 4304 "Subsystem": "cec_vpd", 4305 "ComponentID": "0x4000", 4306 4307 "SRC": { 4308 "ReasonCode": "0x4003", 4309 "Words6To9": 4310 { 4311 } 4312 }, 4313 4314 "Callouts": [ 4315 { 4316 "CalloutList": [ 4317 { "Priority": "high", "Procedure": "bmc_code" } 4318 ] 4319 } 4320 ], 4321 4322 "Documentation": { 4323 "Description": "Invalid Json", 4324 "Message": "A Json failure occurred.", 4325 "Notes": [ 4326 "This error occurs when parser fails to access", 4327 "Json file or there is any issue with Json data.", 4328 "Failed Json path and cause of failure is captured", 4329 "in additional data." 4330 ] 4331 } 4332 }, 4333 4334 { 4335 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 4336 "Subsystem": "cec_vpd", 4337 "ComponentID": "0x4000", 4338 4339 "SRC": { 4340 "ReasonCode": "0x4004", 4341 "Words6To9": 4342 { 4343 } 4344 }, 4345 4346 "Documentation": { 4347 "Description": "System VPD restore failed", 4348 "Message": "A system VPD restoration error occurred.", 4349 "Notes": [ 4350 "This error occurs when restoring of system VPD fails.", 4351 "The FRU path and reason for failure is captured in", 4352 "additional data." 4353 ] 4354 } 4355 }, 4356 4357 { 4358 "Name": "com.ibm.VPD.Error.DbusFailure", 4359 "Subsystem": "cec_vpd", 4360 "ComponentID": "0x4000", 4361 4362 "SRC": { 4363 "ReasonCode": "0x4005", 4364 "Words6To9": 4365 { 4366 } 4367 }, 4368 4369 "Callouts": [ 4370 { 4371 "CalloutList": [ 4372 { "Priority": "high", "Procedure": "bmc_code" } 4373 ] 4374 } 4375 ], 4376 4377 "Documentation": { 4378 "Description": "Dbus exception", 4379 "Message": "A Dbus internal error occurred.", 4380 "Notes": [ 4381 "This error occurs when Dbus operation fails.", 4382 "Exceptions details are captured in additonal", 4383 "data." 4384 ] 4385 } 4386 }, 4387 4388 { 4389 "Name": "com.ibm.VPD.Error.UnknownSystemType", 4390 "Subsystem": "cec_vpd", 4391 "ComponentID": "0x4000", 4392 4393 "SRC": { 4394 "ReasonCode": "0x4006", 4395 "Words6To9": 4396 { 4397 } 4398 }, 4399 4400 "Callouts": [ 4401 { 4402 "CalloutList": [ 4403 { "Priority": "high", "LocCode": "P0" } 4404 ] 4405 } 4406 ], 4407 4408 "Documentation": { 4409 "Description": "Unknown System Type", 4410 "Message": "System type not supported in DTB table.", 4411 "Notes": [ 4412 "System type comes from combination of HW and IM value of system VPD.", 4413 "If anything gets changed in that combination, then it can't determine", 4414 "the appropriate DTB for that system. Need to check HW and IM keywords." 4415 ] 4416 } 4417 }, 4418 4419 { 4420 "Name": "com.ibm.VPD.Error.GPIOError", 4421 "Subsystem": "cec_vpd", 4422 "ComponentID": "0x4000", 4423 4424 "SRC": { 4425 "ReasonCode": "0x4007", 4426 "Words6To9": 4427 { 4428 } 4429 }, 4430 4431 "Callouts": [ 4432 { 4433 "CalloutList": [ 4434 { "Priority": "high", "Procedure": "bmc_code" } 4435 ] 4436 } 4437 ], 4438 4439 "Documentation": { 4440 "Description": "GPIO line error", 4441 "Message": "GPIO line couldn't be found or read.", 4442 "Notes": [ 4443 "The BMC could not access a GPIO line. This can be a hardware issue", 4444 " or driver issue. Since a hardware or a software issue cannot be", 4445 " differentiated, the BMC code will be called out." 4446 ] 4447 } 4448 }, 4449 4450 { 4451 "Name": "com.ibm.VPD.Error.SystemVPDMismatch", 4452 "Subsystem": "cec_vpd", 4453 "ComponentID": "0x4000", 4454 4455 "SRC": { 4456 "ReasonCode": "0x4008", 4457 "Words6To9": 4458 { 4459 } 4460 }, 4461 4462 "Callouts": [ 4463 { 4464 "CalloutList": [ 4465 { "Priority": "high", "Procedure": "bmc_code" } 4466 ] 4467 } 4468 ], 4469 4470 "Documentation": { 4471 "Description": "System VPD restore failed", 4472 "Message": "A system VPD restoration error occurred.", 4473 "Notes": [ 4474 "This error occurs when restoring of system VPD fails due to", 4475 "mismatch in cache data and hardware data.", 4476 "The record and keyword causing the failure is captured in", 4477 "additional data." 4478 ] 4479 } 4480 }, 4481 4482 { 4483 "Name": "com.ibm.VPD.Error.RequiredFRUMissing", 4484 "Subsystem": "cec_vpd", 4485 "ComponentID": "0x4000", 4486 4487 "SRC": { 4488 "ReasonCode": "0x4009", 4489 "Words6To9": 4490 { 4491 } 4492 }, 4493 4494 "Documentation": { 4495 "Description": "Essential FRU check.", 4496 "Message": "Essential FRU check failed", 4497 "Notes": [ 4498 "This error occurs when VPD manager service detects any", 4499 "missing essential FRU. These are FRUs which are required", 4500 "to be present in the system at the time of power on.", 4501 "The inventory path is captured in additional data." 4502 ] 4503 } 4504 }, 4505 4506 { 4507 "Name": "com.ibm.Panel.Error.InputDevPathFailure", 4508 "Subsystem": "cec_op_panel", 4509 "ComponentID": "0x5000", 4510 4511 "SRC": { 4512 "ReasonCode": "0x5001", 4513 "Words6To9": {} 4514 }, 4515 4516 "Documentation": { 4517 "Description": "Button Handler Failure", 4518 "Message": "Input Device path failure", 4519 "Notes": [ 4520 "Button events will not be processed." 4521 ] 4522 } 4523 }, 4524 4525 { 4526 "Name": "com.ibm.Panel.Error.I2CSetupFailure", 4527 "Subsystem": "cec_op_panel", 4528 "ComponentID": "0x5000", 4529 4530 "SRC": { 4531 "ReasonCode": "0x5002", 4532 "Words6To9": {} 4533 }, 4534 4535 "Documentation": { 4536 "Description": "Panel I2C setup failure", 4537 "Message": "Unable to open device path or ioctl failure", 4538 "Notes": [ 4539 "The Panel is unable to open device", 4540 " path or ioctl failure" 4541 ] 4542 } 4543 }, 4544 4545 { 4546 "Name": "com.ibm.Panel.Error.HostCommunicationError", 4547 "Subsystem": "cec_op_panel", 4548 "ComponentID": "0x5000", 4549 4550 "SRC": { 4551 "ReasonCode": "0x5003", 4552 "Words6To9": {} 4553 }, 4554 4555 "Callouts": [{ 4556 "CalloutList": [{ 4557 "Priority": "high", 4558 "Procedure": "bmc_code" 4559 }] 4560 }], 4561 4562 "Documentation": { 4563 "Description": "Host Communication failure", 4564 "Message": "Error in sending message to host", 4565 "Notes": [ 4566 "Failure from PLDM sending message to", 4567 "Host" 4568 ] 4569 } 4570 }, 4571 4572 { 4573 "Name": "com.ibm.Panel.Error.DbusError", 4574 "Subsystem": "cec_op_panel", 4575 "ComponentID": "0x5000", 4576 4577 "SRC": { 4578 "ReasonCode": "0x5004", 4579 "Words6To9": {} 4580 }, 4581 4582 "Callouts": [{ 4583 "CalloutList": [{ 4584 "Priority": "high", 4585 "Procedure": "bmc_code" 4586 }] 4587 }], 4588 4589 "Documentation": { 4590 "Description": "Dbus exception", 4591 "Message": "A Dbus internal error occurred.", 4592 "Notes": [ 4593 "This error occurs when Dbus operation fails.", 4594 "Exceptions details are captured in additional", 4595 "data." 4596 ] 4597 } 4598 }, 4599 4600 { 4601 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 4602 "Subsystem": "cec_sp_hostboot_iface", 4603 4604 "SRC": 4605 { 4606 "ReasonCode": "0xC101", 4607 "Words6To9": 4608 { 4609 } 4610 }, 4611 4612 "Documentation": 4613 { 4614 "Description": "Host did not respond within the watchdog timeout interval", 4615 "Message": "Host did not respond before the watchdog timeout interval expired", 4616 "Notes": [ 4617 "Host did not respond before the expiry of the watchdog timeout interval.", 4618 "Collecting hostboot dump." 4619 ] 4620 } 4621 }, 4622 4623 { 4624 "Name": "xyz.openbmc_project.Software.Version.Error.Incompatible", 4625 "Subsystem": "bmc_firmware", 4626 "ComponentID": "0x3600", 4627 "SRC": 4628 { 4629 "ReasonCode": "0x3601", 4630 "Words6To9": 4631 { 4632 } 4633 }, 4634 4635 "Callouts": [ 4636 { 4637 "CalloutList": [ 4638 { "Priority": "high", "Procedure": "bmc_code" } 4639 ] 4640 } 4641 ], 4642 4643 "Documentation": 4644 { 4645 "Description": "A system component has a software version that is incompatible.", 4646 "Message": "A system component has a software version that is incompatible." 4647 } 4648 }, 4649 4650 { 4651 "Name": "xyz.openbmc_project.Software.Version.Error.AlreadyExists", 4652 "Subsystem": "bmc_firmware", 4653 "ComponentID": "0x3600", 4654 "SRC": 4655 { 4656 "ReasonCode": "0x3602", 4657 "Words6To9": 4658 { 4659 } 4660 }, 4661 4662 "Callouts": [ 4663 { 4664 "CalloutList": [ 4665 { "Priority": "high", "Procedure": "bmc_code" } 4666 ] 4667 } 4668 ], 4669 4670 "Documentation": 4671 { 4672 "Description": "This image version already exists on the device.", 4673 "Message": "This image version already exists on the device." 4674 } 4675 }, 4676 4677 { 4678 "Name": "xyz.openbmc_project.Software.Image.Error.UnTarFailure", 4679 "Subsystem": "bmc_firmware", 4680 "ComponentID": "0x3600", 4681 "SRC": 4682 { 4683 "ReasonCode": "0x3603", 4684 "Words6To9": 4685 { 4686 } 4687 }, 4688 4689 "Callouts": [ 4690 { 4691 "CalloutList": [ 4692 { "Priority": "high", "Procedure": "bmc_code" } 4693 ] 4694 } 4695 ], 4696 4697 "Documentation": 4698 { 4699 "Description": "An error occurred during untar.", 4700 "Message": "An error occurred during untar." 4701 } 4702 }, 4703 4704 { 4705 "Name": "xyz.openbmc_project.Software.Image.Error.ManifestFileFailure", 4706 "Subsystem": "bmc_firmware", 4707 "ComponentID": "0x3600", 4708 "SRC": 4709 { 4710 "ReasonCode": "0x3604", 4711 "Words6To9": 4712 { 4713 } 4714 }, 4715 4716 "Callouts": [ 4717 { 4718 "CalloutList": [ 4719 { "Priority": "high", "Procedure": "bmc_code" } 4720 ] 4721 } 4722 ], 4723 4724 "Documentation": 4725 { 4726 "Description": "An error occurred when reading the software image Manifest file.", 4727 "Message": "An error occurred when reading the software image Manifest file." 4728 } 4729 }, 4730 4731 { 4732 "Name": "xyz.openbmc_project.Software.Image.Error.InternalFailure", 4733 "Subsystem": "bmc_firmware", 4734 "ComponentID": "0x3600", 4735 "SRC": 4736 { 4737 "ReasonCode": "0x3605", 4738 "Words6To9": 4739 { 4740 } 4741 }, 4742 4743 "Callouts": [ 4744 { 4745 "CalloutList": [ 4746 { "Priority": "high", "Procedure": "bmc_code" } 4747 ] 4748 } 4749 ], 4750 4751 "Documentation": 4752 { 4753 "Description": "The operation failed internally during processing the image.", 4754 "Message": "The operation failed internally during processing the image." 4755 } 4756 }, 4757 4758 { 4759 "Name": "xyz.openbmc_project.Software.Image.Error.ImageFailure", 4760 "Subsystem": "bmc_firmware", 4761 "ComponentID": "0x3600", 4762 "SRC": 4763 { 4764 "ReasonCode": "0x3606", 4765 "Words6To9": 4766 { 4767 } 4768 }, 4769 4770 "Callouts": [ 4771 { 4772 "CalloutList": [ 4773 { "Priority": "high", "Procedure": "bmc_code" } 4774 ] 4775 } 4776 ], 4777 4778 "Documentation": 4779 { 4780 "Description": "An error occurred processing the image.", 4781 "Message": "An error occurred processing the image." 4782 } 4783 }, 4784 4785 { 4786 "Name": "xyz.openbmc_project.Software.Image.Error.BusyFailure", 4787 "Subsystem": "bmc_firmware", 4788 "ComponentID": "0x3600", 4789 "SRC": 4790 { 4791 "ReasonCode": "0x3607", 4792 "Words6To9": 4793 { 4794 } 4795 }, 4796 4797 "Callouts": [ 4798 { 4799 "CalloutList": [ 4800 { "Priority": "high", "Procedure": "bmc_code" } 4801 ] 4802 } 4803 ], 4804 4805 "Documentation": 4806 { 4807 "Description": "The device is busy during the update.", 4808 "Message": "The device is busy during the update." 4809 } 4810 }, 4811 4812 { 4813 "Name": "xyz.openbmc_project.Software.Version.Error.ExpiredAccessKey", 4814 "Subsystem": "bmc_firmware", 4815 "ComponentID": "0x3600", 4816 "SRC": 4817 { 4818 "ReasonCode": "0x3608", 4819 "Words6To9": 4820 { 4821 } 4822 }, 4823 4824 "Callouts": [ 4825 { 4826 "CalloutList": [ 4827 { "Priority": "high", "Procedure": "bmc_code" } 4828 ] 4829 } 4830 ], 4831 4832 "Documentation": 4833 { 4834 "Description": "The Update Access Key has expired.", 4835 "Message": "The Update Access Key has expired." 4836 } 4837 }, 4838 4839 { 4840 "Name": "xyz.openbmc_project.Software.Version.Error.InvalidSignature", 4841 "Subsystem": "bmc_firmware", 4842 "ComponentID": "0x3600", 4843 "SRC": 4844 { 4845 "ReasonCode": "0x3609", 4846 "Words6To9": 4847 { 4848 } 4849 }, 4850 4851 "Callouts": [ 4852 { 4853 "CalloutList": [ 4854 { "Priority": "high", "Procedure": "bmc_code" } 4855 ] 4856 } 4857 ], 4858 4859 "Documentation": 4860 { 4861 "Description": "The software image has an invalid signature.", 4862 "Message": "The software image has an invalid signature" 4863 } 4864 }, 4865 4866 { 4867 "Name" : "xyz.openbmc_project.Software.Version.Error.HostFile", 4868 "Subsystem" : "bmc_firmware", 4869 "ComponentID" : "0x3600", 4870 4871 "SRC" : 4872 { 4873 "ReasonCode" : "0x360A", 4874 "Words6To9": 4875 { 4876 "6": 4877 { 4878 "Description" : "Size of the current running partition", 4879 "AdditionalDataPropSource" : "CURRENT_FILE_SIZE" 4880 }, 4881 "7": 4882 { 4883 "Description" : "Size of the read only partition", 4884 "AdditionalDataPropSource" : "EXPECTED_FILE_SIZE" 4885 } 4886 } 4887 }, 4888 "Callouts": [ 4889 { 4890 "CalloutList": [ 4891 { "Priority": "high", "Procedure": "bmc_code" } 4892 ] 4893 } 4894 ], 4895 "Documentation" : 4896 { 4897 "Description" : "Corrupted or changed preserved file", 4898 "Message" : "Partition was not preserved on reboot", 4899 "Notes" : [ 4900 "This error may occur if one of the partitions marked", 4901 "PRESERVED is either corrupted, or a change of size is ", 4902 "desired for a particular partition." 4903 ] 4904 } 4905 }, 4906 4907 { 4908 "Name": "xyz.openbmc_project.PLDM.Error.findDumpObjPath.GetManagedObjectsFail", 4909 "Subsystem": "bmc_firmware", 4910 "ComponentID": "0x6000", 4911 "Severity": "predictive", 4912 "SRC": 4913 { 4914 "ReasonCode": "0x6001", 4915 "Words6To9": 4916 { 4917 } 4918 }, 4919 "Callouts": [ 4920 { 4921 "CalloutList": [ 4922 { "Priority": "high", "Procedure": "bmc_code" } 4923 ] 4924 } 4925 ], 4926 4927 "Documentation": 4928 { 4929 "Description": "Failed to get the requested dump object path.", 4930 "Message": "Failed to get the requested dump object path from the system." 4931 } 4932 }, 4933 { 4934 "Name": "xyz.openbmc_project.PLDM.Error.newFileAvailable.NewDumpNotifyFail", 4935 "Subsystem": "bmc_firmware", 4936 "ComponentID": "0x6000", 4937 "Severity": "unrecoverable", 4938 "SRC": 4939 { 4940 "ReasonCode": "0x6002", 4941 "Words6To9": 4942 { 4943 } 4944 }, 4945 "Callouts": [ 4946 { 4947 "CalloutList": [ 4948 { "Priority": "high", "Procedure": "bmc_code" } 4949 ] 4950 } 4951 ], 4952 "Documentation": 4953 { 4954 "Description": "Failed to make a new dump notify request to the dump manager application.", 4955 "Message": "Failed to make a new dump notify request to the dump manager application." 4956 } 4957 }, 4958 { 4959 "Name": "xyz.openbmc_project.PLDM.Error.DumpHandler.getOffloadUriFail", 4960 "Subsystem": "bmc_firmware", 4961 "ComponentID": "0x6000", 4962 "Severity": "unrecoverable", 4963 "SRC": 4964 { 4965 "ReasonCode": "0x6003", 4966 "Words6To9": 4967 { 4968 } 4969 }, 4970 "Callouts": [ 4971 { 4972 "CalloutList": [ 4973 { "Priority": "high", "Procedure": "bmc_code" } 4974 ] 4975 } 4976 ], 4977 "Documentation": 4978 { 4979 "Description": "Failed to get the dump offload URI path from the dump entry.", 4980 "Message": "Failed to get the dump offload URI path from the dump entry." 4981 } 4982 }, 4983 { 4984 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.ResourceDumpFileAckFail", 4985 "Subsystem": "bmc_firmware", 4986 "ComponentID": "0x6000", 4987 "Severity": "non_error", 4988 "SRC": 4989 { 4990 "ReasonCode": "0x6004", 4991 "Words6To9": 4992 { 4993 } 4994 }, 4995 "Callouts": [ 4996 { 4997 "CalloutList": [ 4998 { "Priority": "medium", "Procedure": "bmc_code" } 4999 ] 5000 } 5001 ], 5002 "Documentation": 5003 { 5004 "Description": "The hypervisor rejected the request to initiate a new resource dump.", 5005 "Message": "The hypervisor rejected the request to initiate a new resource dump." 5006 } 5007 }, 5008 { 5009 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.SourceDumpIdResetFail", 5010 "Subsystem": "bmc_firmware", 5011 "ComponentID": "0x6000", 5012 "Severity": "unrecoverable", 5013 "SRC": 5014 { 5015 "ReasonCode": "0x6005", 5016 "Words6To9": 5017 { 5018 } 5019 }, 5020 "Callouts": [ 5021 { 5022 "CalloutList": [ 5023 { "Priority": "high", "Procedure": "bmc_code" } 5024 ] 5025 } 5026 ], 5027 "Documentation": 5028 { 5029 "Description": "Failed to reset the dump ID, due to this requested dump will not be deleted.", 5030 "Message": "Failed to reset the dump ID, due to this requested dump will not be deleted." 5031 } 5032 }, 5033 { 5034 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryDeleteFail", 5035 "Subsystem": "bmc_firmware", 5036 "ComponentID": "0x6000", 5037 "Severity": "unrecoverable", 5038 "SRC": 5039 { 5040 "ReasonCode": "0x6006", 5041 "Words6To9": 5042 { 5043 } 5044 }, 5045 "Callouts": [ 5046 { 5047 "CalloutList": [ 5048 { "Priority": "high", "Procedure": "bmc_code" } 5049 ] 5050 } 5051 ], 5052 "Documentation": 5053 { 5054 "Description": "Failed to carry out the dump delete request from the hypervisor.", 5055 "Message": "Failed to carry out the dump delete request from the hypervisor." 5056 } 5057 }, 5058 { 5059 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryOffloadedSetFail", 5060 "Subsystem": "bmc_firmware", 5061 "ComponentID": "0x6000", 5062 "Severity": "unrecoverable", 5063 "SRC": 5064 { 5065 "ReasonCode": "0x6007", 5066 "Words6To9": 5067 { 5068 } 5069 }, 5070 "Callouts": [ 5071 { 5072 "CalloutList": [ 5073 { "Priority": "high", "Procedure": "bmc_code" } 5074 ] 5075 } 5076 ], 5077 "Documentation": 5078 { 5079 "Description": "Failed to set the dump offloaded completion flag in the dump entry.", 5080 "Message": "Failed to set the dump offloaded completion flag in the dump entry." 5081 } 5082 }, 5083 { 5084 "Name": "xyz.openbmc_project.PLDM.Error.readIntoMemory.GetFilepathFail", 5085 "Subsystem": "bmc_firmware", 5086 "ComponentID": "0x6000", 5087 "Severity": "unrecoverable", 5088 "SRC": 5089 { 5090 "ReasonCode": "0x6008", 5091 "Words6To9": 5092 { 5093 } 5094 }, 5095 "Callouts": [ 5096 { 5097 "CalloutList": [ 5098 { "Priority": "high", "Procedure": "bmc_code" } 5099 ] 5100 } 5101 ], 5102 "Documentation": 5103 { 5104 "Description": "Failed to get the file path for the BMC dump and offload to the hypervisor.", 5105 "Message": "Failed to get the file path for the BMC dump and offload to the hypervisor." 5106 } 5107 }, 5108 { 5109 "Name": "xyz.openbmc_project.PLDM.Error.read.GetFilepathFail", 5110 "Subsystem": "bmc_firmware", 5111 "ComponentID": "0x6000", 5112 "Severity": "unrecoverable", 5113 "SRC": 5114 { 5115 "ReasonCode": "0x6009", 5116 "Words6To9": 5117 { 5118 } 5119 }, 5120 "Callouts": [ 5121 { 5122 "CalloutList": [ 5123 { "Priority": "high", "Procedure": "bmc_code" } 5124 ] 5125 } 5126 ], 5127 "Documentation": 5128 { 5129 "Description": "Failed to get the file path for the BMC dump and offload to the hypervisor.", 5130 "Message": "Failed to get the file path for the BMC dump and offload to the hypervisor." 5131 } 5132 }, 5133 { 5134 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.ResourceDumpFileAckWithMetaDataFail", 5135 "Subsystem": "bmc_firmware", 5136 "ComponentID": "0x6000", 5137 "Severity": "non_error", 5138 "SRC": 5139 { 5140 "ReasonCode": "0x6010", 5141 "Words6To9": 5142 { 5143 } 5144 }, 5145 "Callouts": [ 5146 { 5147 "CalloutList": [ 5148 { "Priority": "medium", "Procedure": "bmc_code" } 5149 ] 5150 } 5151 ], 5152 "Documentation": 5153 { 5154 "Description": "Could not create a new resource dump due to hypervisor verification failed.", 5155 "Message": "Could not create a new resource dump due to hypervisor verification failed." 5156 } 5157 }, 5158 { 5159 "Name": "xyz.openbmc_project.PLDM.Error.fileAckWithMetaData.DumpEntryOffloadedSetFail", 5160 "Subsystem": "bmc_firmware", 5161 "ComponentID": "0x6000", 5162 "Severity": "unrecoverable", 5163 "SRC": 5164 { 5165 "ReasonCode": "0x6011", 5166 "Words6To9": 5167 { 5168 } 5169 }, 5170 "Callouts": [ 5171 { 5172 "CalloutList": [ 5173 { "Priority": "high", "Procedure": "bmc_code" } 5174 ] 5175 } 5176 ], 5177 "Documentation": 5178 { 5179 "Description": "Failed to set the dump offload completion flag in the dump entry details.", 5180 "Message": "Failed to set the dump offload completion flag in the dump entry details." 5181 } 5182 }, 5183 { 5184 "Name": "xyz.openbmc_project.PLDM.Error.newFileAvailableWithMetaData.NewDumpNotifyFail", 5185 "Subsystem": "bmc_firmware", 5186 "ComponentID": "0x6000", 5187 "Severity": "unrecoverable", 5188 "SRC": 5189 { 5190 "ReasonCode": "0x6012", 5191 "Words6To9": 5192 { 5193 } 5194 }, 5195 "Callouts": [ 5196 { 5197 "CalloutList": [ 5198 { "Priority": "high", "Procedure": "bmc_code" } 5199 ] 5200 } 5201 ], 5202 "Documentation": 5203 { 5204 "Description": "Failed to notify a new dump available request.", 5205 "Message": "Failed to notify a new dump available request." 5206 } 5207 }, 5208 { 5209 "Name": "xyz.openbmc_project.PLDM.Error.sendNewFileAvailableCmd.SendDumpParametersFail", 5210 "Subsystem": "bmc_firmware", 5211 "ComponentID": "0x6000", 5212 "Severity": "unrecoverable", 5213 "SRC": 5214 { 5215 "ReasonCode": "0x6013", 5216 "Words6To9": 5217 { 5218 } 5219 }, 5220 "Callouts": [ 5221 { 5222 "CalloutList": [ 5223 { "Priority": "high", "Procedure": "bmc_code" } 5224 ] 5225 } 5226 ], 5227 "Documentation": 5228 { 5229 "Description": "Failed to send the resource dump parameters for a new dump initiation.", 5230 "Message": "Failed to send the resource dump parameters for a new dump initiation." 5231 } 5232 }, 5233 { 5234 "Name": "xyz.openbmc_project.PLDM.Error.SendFileToHostFail", 5235 "Subsystem": "bmc_firmware", 5236 "ComponentID": "0x6000", 5237 "Severity": "unrecoverable", 5238 "SRC": 5239 { 5240 "ReasonCode": "0x6014", 5241 "Words6To9": 5242 { 5243 } 5244 }, 5245 "Callouts": [ 5246 { 5247 "CalloutList": [ 5248 { "Priority": "high", "Procedure": "bmc_code" } 5249 ] 5250 } 5251 ], 5252 "Documentation": 5253 { 5254 "Description": "Failed to send the certificate/license file to the host.", 5255 "Message": "Failed to send the certificate/license file to the host." 5256 } 5257 }, 5258 { 5259 "Name": "xyz.openbmc_project.PLDM.Error.DecodeNewFileResponseFail", 5260 "Subsystem": "bmc_firmware", 5261 "ComponentID": "0x6000", 5262 "Severity": "unrecoverable", 5263 "SRC": 5264 { 5265 "ReasonCode": "0x6015", 5266 "Words6To9": 5267 { 5268 } 5269 }, 5270 "Callouts": [ 5271 { 5272 "CalloutList": [ 5273 { "Priority": "high", "Procedure": "bmc_code" } 5274 ] 5275 } 5276 ], 5277 "Documentation": 5278 { 5279 "Description": "Failed to decode the response of certificate/license file sent to the host.", 5280 "Message": "Failed to decode the response of certificate/license file sent to the host." 5281 } 5282 }, 5283 { 5284 "Name": "xyz.openbmc_project.PLDM.Error.NewFileAvailableRequestFail", 5285 "Subsystem": "bmc_firmware", 5286 "ComponentID": "0x6000", 5287 "Severity": "unrecoverable", 5288 "SRC": 5289 { 5290 "ReasonCode": "0x6016", 5291 "Words6To9": 5292 { 5293 } 5294 }, 5295 "Callouts": [ 5296 { 5297 "CalloutList": [ 5298 { "Priority": "high", "Procedure": "bmc_code" } 5299 ] 5300 } 5301 ], 5302 "Documentation": 5303 { 5304 "Description": "Failed to send the new certificate/license file to the host.", 5305 "Message": "Failed to send the new certificate/license file to the host." 5306 } 5307 }, 5308 { 5309 "Name": "xyz.openbmc_project.PLDM.Error.SetHostEffecterFailed", 5310 "Subsystem": "bmc_firmware", 5311 "ComponentID": "0x6000", 5312 "Severity": "unrecoverable", 5313 "SRC": 5314 { 5315 "ReasonCode": "0x6017", 5316 "Words6To9": 5317 { 5318 } 5319 }, 5320 5321 "Callouts": [ 5322 { 5323 "CalloutList": [ 5324 { "Priority": "high", "Procedure": "bmc_code" } 5325 ] 5326 } 5327 ], 5328 "Documentation": 5329 { 5330 "Description": "Failed to set state effecter states.", 5331 "Message": "Failed to set state effecter states." 5332 } 5333 }, 5334 { 5335 "Name": "xyz.openbmc_project.PLDM.Error.Generate.PDRJsonFileParseFail", 5336 "Subsystem": "bmc_firmware", 5337 "ComponentID": "0x6000", 5338 "Severity": "unrecoverable", 5339 "SRC": 5340 { 5341 "ReasonCode": "0x6018", 5342 "Words6To9": 5343 { 5344 } 5345 }, 5346 "Callouts": [ 5347 { 5348 "CalloutList": [ 5349 { "Priority": "high", "Procedure": "bmc_code" } 5350 ] 5351 } 5352 ], 5353 "Documentation": 5354 { 5355 "Description": "Failed to parse PDR JSON file.", 5356 "Message": "Failed to parse PDR JSON file." 5357 } 5358 }, 5359 { 5360 "Name": "xyz.openbmc_project.PLDM.Error.SetHostSensorState.GetStateSensorPDRFail", 5361 "Subsystem": "bmc_firmware", 5362 "ComponentID": "0x6000", 5363 "Severity": "unrecoverable", 5364 "SRC": 5365 { 5366 "ReasonCode": "0x6019", 5367 "Words6To9": 5368 { 5369 } 5370 }, 5371 "Callouts": [ 5372 { 5373 "CalloutList": [ 5374 { "Priority": "high", "Procedure": "bmc_code" } 5375 ] 5376 } 5377 ], 5378 "Documentation": 5379 { 5380 "Description": "Failed to get state sensor PDR state.", 5381 "Message": "Failed to get state sensor PDR state." 5382 } 5383 }, 5384 { 5385 "Name": "xyz.openbmc_project.PLDM.Error.SetHostSensorState.EncodeStateSensorFail", 5386 "Subsystem": "bmc_firmware", 5387 "ComponentID": "0x6000", 5388 "Severity": "unrecoverable", 5389 "SRC": 5390 { 5391 "ReasonCode": "0x6020", 5392 "Words6To9": 5393 { 5394 } 5395 }, 5396 "Callouts": [ 5397 { 5398 "CalloutList": [ 5399 { "Priority": "high", "Procedure": "bmc_code" } 5400 ] 5401 } 5402 ], 5403 "Documentation": 5404 { 5405 "Description": "Failed to encode state sensor request.", 5406 "Message": "Failed to encode state sensor request." 5407 } 5408 }, 5409 { 5410 "Name": "xyz.openbmc_project.PLDM.Error.CMsubscribeFailure", 5411 "Subsystem": "bmc_firmware", 5412 "ComponentID": "0x6000", 5413 "Severity": "unrecoverable", 5414 "SRC": 5415 { 5416 "ReasonCode": "0x6021", 5417 "Words6To9": 5418 { 5419 } 5420 }, 5421 "Callouts": [ 5422 { 5423 "CalloutList": [ 5424 { "Priority": "high", "Procedure": "bmc_code" } 5425 ] 5426 } 5427 ], 5428 "Documentation": 5429 { 5430 "Description": "Failed to subscribe for concurrent maintenance of FRU.", 5431 "Message": "Failed to subscribe for concurrent maintenance of FRU." 5432 } 5433 }, 5434 { 5435 "Name": "xyz.openbmc_project.PLDM.Error.setSurvTimer.RecvSurveillancePingFail", 5436 "Subsystem": "bmc_firmware", 5437 "ComponentID": "0x6000", 5438 "Severity": "non_error", 5439 "SRC": 5440 { 5441 "ReasonCode": "0x6022", 5442 "Words6To9": 5443 { 5444 } 5445 }, 5446 "Callouts": [ 5447 { 5448 "CalloutList": [ 5449 { "Priority": "high", "Procedure": "bmc_code" } 5450 ] 5451 } 5452 ], 5453 "Documentation": 5454 { 5455 "Description": "Host did not send a surveillance ping within stipulated timeout interval.", 5456 "Message": "Host did not send a surveillance ping within stipulated timeout interval." 5457 } 5458 }, 5459 { 5460 "Name": "xyz.openbmc_project.PLDM.Error.fileAck.DumpEntryOffloadUriSetFail", 5461 "Subsystem": "bmc_firmware", 5462 "ComponentID": "0x6000", 5463 "Severity": "unrecoverable", 5464 "SRC": 5465 { 5466 "ReasonCode": "0x6023", 5467 "Words6To9": 5468 { 5469 } 5470 }, 5471 "Callouts": [ 5472 { 5473 "CalloutList": [ 5474 { "Priority": "high", "Procedure": "bmc_code" } 5475 ] 5476 } 5477 ], 5478 "Documentation": 5479 { 5480 "Description": "Failed to reset the dump offload URI path from the dump entry.", 5481 "Message": "Failed to reset the dump offload URI path from the dump entry." 5482 } 5483 }, 5484 { 5485 "Name": "xyz.openbmc_project.PLDM.Error.SoftPowerOff.HostSoftOffTimeOut", 5486 "Subsystem": "bmc_firmware", 5487 "ComponentID": "0x6000", 5488 "Severity": "unrecoverable", 5489 "SRC": 5490 { 5491 "ReasonCode": "0x6024", 5492 "Words6To9": 5493 { 5494 } 5495 }, 5496 "Callouts": [ 5497 { 5498 "CalloutList": [ 5499 { "Priority": "high", "Procedure": "bmc_code" } 5500 ] 5501 } 5502 ], 5503 "Documentation": 5504 { 5505 "Description": "Host failed to complete the power off gracefully within the timeout.", 5506 "Message": "Host failed to complete the power off gracefully within the timeout." 5507 } 5508 } 5509 ] 5510} 5511