1{ 2 "PELs": 3 [ 4 { 5 "Name": "xyz.openbmc_project.Common.Error.Timeout", 6 "Subsystem": "bmc_firmware", 7 8 "SRC": 9 { 10 "ReasonCode": "0x1001", 11 "Words6To9": 12 { 13 "6": 14 { 15 "Description": "Timeout in ms", 16 "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" 17 } 18 } 19 }, 20 21 "Documentation": 22 { 23 "Description": "This is a generic timeout error", 24 "Message": "An operation timed out", 25 "Notes": [ 26 "The journal should contain more information" 27 ] 28 } 29 }, 30 31 { 32 "Name": "xyz.openbmc_project.Common.Error.InternalFailure", 33 "Subsystem": "bmc_firmware", 34 35 "SRC": 36 { 37 "ReasonCode": "0x1002", 38 "Words6To9": 39 { 40 } 41 }, 42 43 "Documentation": 44 { 45 "Description": "BMC code had a generic internal failure", 46 "Message": "An application had an internal failure", 47 "Notes": [ 48 "The journal should contain more information" 49 ] 50 } 51 }, 52 53 { 54 "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", 55 "Subsystem": "user_error", 56 57 "SRC": 58 { 59 "ReasonCode": "0x1003", 60 "Words6To9": 61 { 62 } 63 }, 64 65 "Documentation": 66 { 67 "Description": "BMC code was given an invalid argument", 68 "Message": "Code was given an invalid argument", 69 "Notes": [ 70 "The journal should contain more information" 71 ] 72 } 73 }, 74 { 75 "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", 76 "Subsystem": "user_error", 77 78 "SRC": 79 { 80 "ReasonCode": "0x1004", 81 "Words6To9": 82 { 83 } 84 }, 85 86 "Documentation": 87 { 88 "Description": "An operation failed due to insufficient permission", 89 "Message": "An operation failed due to unsufficient permission", 90 "Notes": [ 91 "The journal should contain more information" 92 ] 93 } 94 }, 95 96 { 97 "Name": "xyz.openbmc_project.Common.Error.NotAllowed", 98 "Subsystem": "user_error", 99 100 "SRC": 101 { 102 "ReasonCode": "0x1005", 103 "Words6To9": 104 { 105 } 106 }, 107 108 "Documentation": 109 { 110 "Description": "An operation failed because it isn't allowed", 111 "Message": "An operation failed because it isn't allowed", 112 "Notes": [ 113 "The journal should contain more information" 114 ] 115 } 116 }, 117 118 { 119 "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", 120 "Subsystem": "user_error", 121 122 "SRC": 123 { 124 "ReasonCode": "0x1006", 125 "Words6To9": 126 { 127 } 128 }, 129 130 "Documentation": 131 { 132 "Description": "The server's CA certificate has not been provided", 133 "Message": "The server's CA certificate has not been provided" 134 } 135 }, 136 137 { 138 "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", 139 "Subsystem": "cec_chip_iface", 140 141 "SRC": 142 { 143 "ReasonCode": "0x1007", 144 "Words6To9": 145 { 146 "6": 147 { 148 "Description": "errno of the failure", 149 "AdditionalDataPropSource": "CALLOUT_ERRNO" 150 } 151 } 152 }, 153 154 "Documentation": 155 { 156 "Description": "Sensor device read failure", 157 "Message": "There was a failure when reading a sensor device", 158 "Notes": [ 159 "The severity is set by the creator.", 160 "The action flags are set automatically by the code.", 161 "Callouts added based on CALLOUT_DEVICE_PATH." 162 ] 163 } 164 }, 165 166 { 167 "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", 168 "Subsystem": "cec_chip_iface", 169 170 "SRC": 171 { 172 "ReasonCode": "0x1008", 173 "Words6To9": 174 { 175 "6": 176 { 177 "Description": "errno of the failure", 178 "AdditionalDataPropSource": "CALLOUT_ERRNO" 179 } 180 } 181 }, 182 183 "Documentation": 184 { 185 "Description": "Device read failure", 186 "Message": "There was a failure when reading a hardware device", 187 "Notes": [ 188 "The severity is set by the creator.", 189 "The action flags are set automatically by the code.", 190 "Callouts added based on CALLOUT_DEVICE_PATH." 191 ] 192 } 193 }, 194 195 { 196 "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", 197 "Subsystem": "cec_chip_iface", 198 199 "SRC": 200 { 201 "ReasonCode": "0x1009", 202 "Words6To9": 203 { 204 "6": 205 { 206 "Description": "errno of the failure", 207 "AdditionalDataPropSource": "CALLOUT_ERRNO" 208 } 209 } 210 }, 211 212 "Documentation": 213 { 214 "Description": "Device write failure", 215 "Message": "There was a failure when writing to a hardware device", 216 "Notes": [ 217 "The severity is set by the creator.", 218 "The action flags are set automatically by the code.", 219 "Callouts added based on CALLOUT_DEVICE_PATH" 220 ] 221 } 222 }, 223 224 { 225 "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", 226 "Subsystem": "cec_chip_iface", 227 228 "SRC": 229 { 230 "ReasonCode": "0x100A", 231 "Words6To9": 232 { 233 "6": 234 { 235 "Description": "errno of the failure", 236 "AdditionalDataPropSource": "CALLOUT_ERRNO" 237 } 238 } 239 }, 240 241 "Documentation": 242 { 243 "Description": "Device write failure", 244 "Message": "There was a failure when writing to a hardware device", 245 "Notes": [ 246 "The severity is set by the creator.", 247 "The action flags are set automatically by the code.", 248 "Callouts added based on CALLOUT_DEVICE_PATH" 249 ] 250 } 251 }, 252 253 { 254 "Name": "org.open_power.Logging.Error.SentBadPELToHost", 255 "Subsystem": "bmc_firmware", 256 "Severity": "non_error", 257 258 "SRC": 259 { 260 "ReasonCode": "0x2001", 261 "Words6To9": 262 { 263 "6": 264 { 265 "Description": "The bad PEL ID", 266 "AdditionalDataPropSource": "BAD_ID" 267 } 268 } 269 }, 270 271 "Documentation": 272 { 273 "Description": "The BMC sent the host a malformed PEL", 274 "Message": "The BMC sent the host a malformed PEL", 275 "Notes": [ 276 "The host firmware rejected that PEL." 277 ] 278 } 279 }, 280 281 { 282 "Name": "org.open_power.Logging.Error.BadHostPEL", 283 "Subsystem": "platform_firmware", 284 "Severity": "unrecoverable", 285 286 "SRC": 287 { 288 "ReasonCode": "0x2002", 289 "Words6To9": 290 { 291 "6": 292 { 293 "Description": "The PLID of the invalid PEL", 294 "AdditionalDataPropSource": "PLID" 295 }, 296 "7": 297 { 298 "Description": "The corresponding OpenBMC event log ID", 299 "AdditionalDataPropSource": "OBMC_LOG_ID" 300 }, 301 "8": 302 { 303 "Description": "The size of the invalid PEL", 304 "AdditionalDataPropSource": "PEL_SIZE" 305 } 306 } 307 }, 308 309 "Documentation": 310 { 311 "Description": "The host sent the BMC an invalid PEL", 312 "Message": "The host sent the BMC an invalid PEL", 313 "Notes": [ 314 ] 315 } 316 }, 317 318 { 319 "Name": "org.open_power.Logging.Error.TestError1", 320 "Subsystem": "platform_firmware", 321 "Severity": "unrecoverable", 322 323 "SRC": 324 { 325 "ReasonCode": "0x2003", 326 "Words6To9": 327 { 328 } 329 }, 330 331 "Callouts": [ 332 { 333 "CalloutList": [ 334 {"Priority": "high", "Procedure": "bmc_code"}, 335 {"Priority": "medium", "SymbolicFRU": "service_docs"} 336 ] 337 } 338 ], 339 340 "Documentation": 341 { 342 "Description": "An error for testing", 343 "Message": "This is a test error" 344 } 345 }, 346 347 { 348 "Name": "xyz.openbmc_project.Logging.Error.Default", 349 "Subsystem": "other_na", 350 351 "SRC": 352 { 353 "ReasonCode": "0x2004", 354 "Words6To9": 355 { 356 } 357 }, 358 359 "Documentation": 360 { 361 "Description": "This entry is used when no other matching entry is found", 362 "Message": "Unknown (Original event not in message registry)", 363 "Notes": [ 364 "This is used when the actual error name isn't found in ", 365 "the registry. The original error name will be stored ", 366 "in the UserData section that contains the AdditionalData ", 367 "properties using the key ERROR_NAME.", 368 "This error may contain callouts if the creator passed ", 369 "them in.", 370 "The severity is set by the creator.", 371 "If this error is seen, then a code change needs to be ", 372 "made to add the missing error entry to this registry." 373 ] 374 } 375 }, 376 377 { 378 "Name": "org.open_power.PHAL.Error.Boot", 379 "Subsystem": "cec_hardware", 380 "ComponentID": "0x3000", 381 "Severity": "unrecoverable", 382 383 "SRC": 384 { 385 "ReasonCode": "0x3001", 386 "Words6To9": 387 { 388 } 389 }, 390 391 "Documentation": 392 { 393 "Description": "Failure occured during boot process", 394 "Message": "Failure occured during boot process", 395 "Notes": [ 396 "Debug traces will be captured in AdditionalData section" 397 ] 398 } 399 }, 400 401 { 402 "Name": "org.open_power.PHAL.Error.PrePowerOff", 403 "Subsystem": "cec_hardware", 404 "ComponentID": "0x3000", 405 406 "SRC": 407 { 408 "ReasonCode": "0x3002", 409 "Words6To9": 410 { 411 } 412 }, 413 414 "Documentation": 415 { 416 "Description": "Failure occurred during PHAL pre-poweroff operations", 417 "Message": "Failure occurred during PHAL pre-poweroff operations", 418 "Notes": [ 419 "Severity needs to be set based on needs for this registry.", 420 "FFDC (First Failure Data Collection) will be collected ", 421 "and added into PEL." 422 ] 423 } 424 }, 425 426 { 427 "Name": "org.open_power.PHAL.Error.devtreeSync", 428 "Subsystem": "cec_hardware", 429 "ComponentID": "0x3000", 430 "Severity": "unrecoverable", 431 432 "SRC": 433 { 434 "ReasonCode": "0x3003", 435 "Words6To9": 436 { 437 } 438 }, 439 440 "Documentation": 441 { 442 "Description": "Failure occurred during PHAL devtree sync ", 443 "Message": "Failure occurred during PHAL devtree sync", 444 "Notes": [ 445 "The journal should contain more information" 446 ] 447 } 448 }, 449 450 { 451 "Name": "org.open_power.PHAL.Error.devtreeBackup", 452 "Subsystem": "cec_hardware", 453 "ComponentID": "0x3000", 454 "Severity": "unrecoverable", 455 456 "SRC": 457 { 458 "ReasonCode": "0x3004", 459 "Words6To9": 460 { 461 } 462 }, 463 464 "Documentation": 465 { 466 "Description": "Failure occurred during PHAL devtree backup ", 467 "Message": "Failure occurred during PHAL devtree backup", 468 "Notes": [ 469 "The journal should contain more information" 470 ] 471 } 472 }, 473 474 { 475 "Name": "org.open_power.PHAL.Error.HostRunning", 476 "Subsystem": "cec_sp_hostboot_iface", 477 "ComponentID": "0x3000", 478 479 "SRC": 480 { 481 "ReasonCode": "0x3005", 482 "Words6To9": 483 { 484 } 485 }, 486 487 "Documentation": 488 { 489 "Description": "Host did not respond to BMC after a BMC reset", 490 "Message": "Host did not respond to BMC after a BMC reset but hardware indicates it is running", 491 "Notes": [ 492 "System will be left in its current state to ensure host ", 493 "is not unexpectedly taken down. There is most likely an ", 494 "issue in the software or hardware communication path ", 495 "between the BMC and the Host firmware.", 496 "A BMC dump will be collected with relevant FFDC." 497 ] 498 } 499 }, 500 501 { 502 "Name": "org.open_power.HardwareIsolation.Error", 503 "Subsystem": "cec_hardware", 504 "ComponentID": "0x3100", 505 506 "SRC": 507 { 508 "ReasonCode": "0x3101", 509 "Words6To9": 510 { 511 } 512 }, 513 514 "Documentation": 515 { 516 "Description": "Failure occured during hardware isolation operations", 517 "Message": "Failure occured during hardware isolation operations", 518 "Notes": [ 519 "Severity needs to be set based on needs for this registry.", 520 "Debug traces will be captured in AdditionalData section" 521 ] 522 } 523 }, 524 525 { 526 "Name": "xyz.openbmc_project.State.Error.HostNotRunning", 527 "Subsystem": "cec_sp_hostboot_iface", 528 "ComponentID": "0x3400", 529 "SRC": 530 { 531 "ReasonCode": "0x3401", 532 "Words6To9": 533 { 534 } 535 }, 536 "Documentation": 537 { 538 "Description": "Host was booting or booted before BMC reset but is now unresponsive", 539 "Message": "Host did not respond to BMC after a BMC reset but it was booting or booted prior to the BMC reboot", 540 "Notes": [ 541 "System will follow recovery policy, resulting in this ", 542 "error and most likely a a reboot of the host. The issue ", 543 "is most likely the result of the BMC rebooting while the ", 544 "host was booting and in a state where it still needed ", 545 "the BMC to complete its boot." 546 ] 547 } 548 }, 549 550 { 551 "Name": "org.open_power.Processor.Error.SbeChipOpFailure", 552 "Subsystem": "processor_chip", 553 "ComponentID": "0x3500", 554 555 "SRC": 556 { 557 "ReasonCode": "0x3500", 558 "Words6To9": 559 { 560 "6": 561 { 562 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 563 "AdditionalDataPropSource": "SRC6" 564 } 565 } 566 }, 567 568 "Documentation": 569 { 570 "Description": "chipop failure with SBE provided FFDC", 571 "Message": "chipop request failure reported by SBE", 572 "Notes": [ 573 "The severity is set by the creator.", 574 "Callouts added based on SBE provided FFDC.", 575 "SBE provided additional debug data included as part of the", 576 "additional user data section." 577 ] 578 } 579 }, 580 581 { 582 "Name": "org.open_power.Processor.Error.SbeChipOpTimeout", 583 "Subsystem": "processor_chip", 584 "ComponentID": "0x3500", 585 586 "SRC": 587 { 588 "ReasonCode": "0x3501", 589 "Words6To9": 590 { 591 "6": 592 { 593 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 594 "AdditionalDataPropSource": "SRC6" 595 } 596 } 597 }, 598 599 "Documentation": 600 { 601 "Description": "SBE chipop timeout", 602 "Message": "chipop timeout reported during SBE communication", 603 "Notes": [ 604 "The severity is set by the creator.", 605 "Check SBE Dump associated to this error to debug the failure." 606 ] 607 } 608 }, 609 610 { 611 "Name": "org.open_power.Processor.Error.SbeChipOpInvalidState", 612 "Subsystem": "processor_chip", 613 "ComponentID": "0x3500", 614 615 "SRC": 616 { 617 "ReasonCode": "0x3502", 618 "Words6To9": 619 { 620 "6": 621 { 622 "Description": "[0:15] chip position, [16:23] command class, [24:31] command type", 623 "AdditionalDataPropSource": "SRC6" 624 }, 625 "7": 626 { 627 "Description": "Value of SBE state", 628 "AdditionalDataPropSource": "SRC7" 629 } 630 } 631 }, 632 633 "Documentation": 634 { 635 "Description": "The SBE on this processor is not in a state where chipOps can be issued", 636 "Message": "SBE Chipop is not allowed due to invalid SBE state ", 637 "Notes": [ 638 "The severity is set by the creator." 639 ] 640 } 641 }, 642 643 { 644 "Name": "org.open_power.Processor.Error.SbeBootFailure", 645 "Subsystem": "processor_chip", 646 "ComponentID": "0x3500", 647 648 "SRC": 649 { 650 "ReasonCode": "0x3503", 651 "Words6To9": 652 { 653 "6": 654 { 655 "Description": "[0:15] chip position", 656 "AdditionalDataPropSource": "SRC6" 657 } 658 } 659 }, 660 661 "Documentation": 662 { 663 "Description": "Boot failure with SBE provided FFDC", 664 "Message": "Boot failure reported by SBE", 665 "Notes": [ 666 "The severity is set by the creator.", 667 "Callouts added based on SBE provided FFDC.", 668 "SBE provided additional debug data included as part of the", 669 "additional user data section." 670 ] 671 } 672 }, 673 674 { 675 "Name": "org.open_power.Processor.Error.SbeBootTimeout", 676 "Subsystem": "processor_chip", 677 "ComponentID": "0x3500", 678 679 "SRC": 680 { 681 "ReasonCode": "0x3504", 682 "Words6To9": 683 { 684 } 685 }, 686 687 "Documentation": 688 { 689 "Description": "SBE Boot timeout", 690 "Message": "timeout reported during SBE boot process", 691 "Notes": [ 692 "The severity is set by the creator.", 693 "Check SBE Dump associated to this error to debug the failure." 694 ] 695 } 696 }, 697 698 { 699 "Name": "org.open_power.Attn.Error.Terminate", 700 "Subsystem": "cec_hardware", 701 "Severity": "non_error", 702 703 "SRC": 704 { 705 "ReasonCode": "0xD138", 706 "SymptomIDFields": [ "SRCWord3", "SRCWord4", "SRCWord5", "SRCWord6", "SRCWord7", "SRCWord8", "SRCWord9" ], 707 "Words6To9": 708 { 709 } 710 }, 711 712 "Documentation": 713 { 714 "Description": "Status shows TI special attention active", 715 "Message": "TI special attention detected", 716 "Notes": [ 717 "This entry is for any TI special attention event ", 718 "reported by the attention handler component" 719 ] 720 } 721 }, 722 723 { 724 "Name": "org.open_power.Attn.Error.Fail", 725 "Subsystem": "bmc_firmware", 726 "Severity": "unrecoverable_loss_of_function", 727 728 "SRC": 729 { 730 "ReasonCode": "0xD13E", 731 "Words6To9": 732 { 733 "6": 734 { 735 "Description": "Error code from attention handler", 736 "AdditionalDataPropSource": "ERROR_CODE" 737 } 738 } 739 }, 740 "Documentation": 741 { 742 "Description": "The attention handler encountered an error", 743 "MessageArgSources" : ["SRCWord6"], 744 "Message": "Attention handler error %1", 745 "Notes": [ 746 "Attention handler will provide error code" 747 ] 748 } 749 }, 750 751 { 752 "Name": "org.open_power.Attn.Error.Vital", 753 "Subsystem": "processor_chip", 754 "Severity": "critical", 755 756 "SRC": 757 { 758 "ReasonCode": "0xD16D", 759 "Words6To9": 760 { 761 } 762 }, 763 764 "Documentation": 765 { 766 "Description": "Status shows SBE vital attention active", 767 "Message": "SBE vital attention detected", 768 "Notes": [ 769 "This entry is for any SBE vital attention event ", 770 "reported by the attention handler component" 771 ] 772 } 773 }, 774 775 { 776 "Name": "org.open_power.HwDiags.Error.Checkstop", 777 "Subsystem": "cec_hardware", 778 "ActionFlags": [ "service_action", "report", "call_home" ], 779 780 "SRC": 781 { 782 "ReasonCode": "0xE510", 783 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 784 "Words6To9": 785 { 786 "6": 787 { 788 "AdditionalDataPropSource": "SRC6" 789 }, 790 "7": 791 { 792 "AdditionalDataPropSource": "SRC7" 793 }, 794 "8": 795 { 796 "AdditionalDataPropSource": "SRC8" 797 } 798 } 799 }, 800 801 "Documentation": 802 { 803 "Description": "A system checkstop attention has occurred", 804 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 805 "Message": "Error Signature: %1 %2 %3" 806 } 807 }, 808 809 { 810 "Name": "org.open_power.HwDiags.Error.Predictive", 811 "Subsystem": "cec_hardware", 812 "ActionFlags": [ "service_action", "report", "call_home" ], 813 814 "SRC": 815 { 816 "ReasonCode": "0xE511", 817 "SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ], 818 "Words6To9": 819 { 820 "6": 821 { 822 "AdditionalDataPropSource": "SRC6" 823 }, 824 "7": 825 { 826 "AdditionalDataPropSource": "SRC7" 827 }, 828 "8": 829 { 830 "AdditionalDataPropSource": "SRC8" 831 } 832 } 833 }, 834 835 "Documentation": 836 { 837 "Description": "A hardware attention requiring service has occurred", 838 "MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ], 839 "Message": "Error Signature: %1 %2 %3" 840 } 841 }, 842 843 { 844 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", 845 "Subsystem": "power_supply", 846 "Severity": "unrecoverable_redundancy_loss", 847 "ActionFlags": ["service_action", "report"], 848 "ComponentID": "0x2700", 849 850 "SRC": { 851 "Type": "11", 852 "ReasonCode": "0x15F0", 853 "Words6To9": {} 854 }, 855 856 "Callouts": [ 857 { 858 "CalloutList": [ 859 { "Priority": "high", "SymbolicFRU": "pwrsply" } 860 ] 861 } 862 ], 863 864 "Documentation": { 865 "Description": "Power Supply input power fault", 866 "Message": "A power supply has indicated an input or under voltage condition.", 867 "Notes": [ 868 "Check the power supply cabling and/or input power ", 869 "source. The PWRSPLY procedure is used rather than ", 870 "calling out a location code, as typically these faults ", 871 "are related to the supplied power, the cable, or the ", 872 "cable connectors. If the input fault resolves down to an ", 873 "issue with the power supply itself, the power supply ", 874 "indicating this input fault should be called out. Add the ", 875 "CALLOUT_INVENTORY_PATH to the additional data, and set the", 876 "CALLOUT_PRIORITY to something other than high." 877 ] 878 } 879 }, 880 881 { 882 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", 883 "Subsystem": "power_supply", 884 "Severity": "unrecoverable_redundancy_loss", 885 "ActionFlags": ["service_action", "report", "call_home"], 886 "ComponentID": "0x2700", 887 888 "SRC": { 889 "Type": "11", 890 "ReasonCode": "0x15F1", 891 "Words6To9": {} 892 }, 893 894 "Documentation": { 895 "Description": "Power Supply power fault", 896 "Message": "The power supply detected a fault condition, see AdditionalData for further details.", 897 "Notes": [ 898 "The power supply reporting the fault should be called ", 899 "out using the CALLOUT_INVENTORY_PATH keyword. Include ", 900 "specific fault, STATUS_* details, and code level in the ", 901 "AdditionalData section." 902 ] 903 } 904 }, 905 906 { 907 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", 908 "Subsystem": "power_supply", 909 "Severity": "unrecoverable", 910 "ActionFlags": ["service_action", "report", "call_home"], 911 "ComponentID": "0x2700", 912 913 "SRC": { 914 "Type": "11", 915 "ReasonCode": "0x15F2", 916 "Words6To9": {} 917 }, 918 919 "Documentation": { 920 "Description": "Power Supply non-power fault", 921 "Message": "A communication failure occurred talking to the power supply", 922 "Notes": [ 923 "Communication problems with the power supply could be ", 924 "the power supply, or any hardware between it and the ", 925 "BMC. Reporting the error should be passing in a call ", 926 "out using CALLOUT_DEVICE_PATH." 927 ] 928 } 929 }, 930 931 { 932 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", 933 "Subsystem": "power_supply", 934 "Severity": "unrecoverable_redundancy_loss", 935 "ActionFlags": ["service_action", "report", "call_home"], 936 "ComponentID": "0x2700", 937 938 "SRC": { 939 "Type": "11", 940 "ReasonCode": "0x15F6", 941 "Words6To9": {} 942 }, 943 944 "Callouts": [ 945 { 946 "CalloutList": [ 947 { 948 "Priority": "high", 949 "SymbolicFRUTrusted": "pwrsply", 950 "UseInventoryLocCode": true 951 } 952 ] 953 } 954 ], 955 956 "Documentation": { 957 "Description": "Power Supply is missing", 958 "Message": "A power supply that should be present is missing", 959 "Notes": [ 960 "The CalloutList should use the PWRSPLY symbolic FRU ", 961 "with the trusted location code property. The ", 962 "location code in this callout is obtained from ", 963 "the passed in CALLOUT_INVENTORY_PATH value." 964 ] 965 } 966 }, 967 968 { 969 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.NotSupported", 970 "Subsystem": "power_supply", 971 "Severity": "unrecoverable", 972 "ActionFlags": ["service_action", "report", "call_home"], 973 "ComponentID": "0x2700", 974 975 "SRC": { 976 "Type": "11", 977 "ReasonCode": "0x15F7", 978 "Words6To9": {} 979 }, 980 981 "Documentation": { 982 "Description": "Power Supply configuration is not supported", 983 "Message": "The power supply configuration is not supported", 984 "Notes": [ 985 "The combination of power supplies detected in the ", 986 "system is not supported. This could be caused by ", 987 "mismatched models, less than expected number of power ", 988 "supplies, or other unsupported characteristics." 989 ] 990 } 991 }, 992 993 { 994 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.IoutOCFault", 995 "Subsystem": "power_supply", 996 "Severity": "unrecoverable_redundancy_loss", 997 "ActionFlags": ["service_action", "report", "call_home"], 998 "ComponentID": "0x2700", 999 1000 "SRC": { 1001 "Type": "11", 1002 "ReasonCode": "0x1B01", 1003 "Words6To9": {} 1004 }, 1005 1006 "Callouts": [ 1007 { 1008 "CalloutList": [ 1009 { "Priority": "high", "Procedure": "power_overcurrent" } 1010 ] 1011 } 1012 ], 1013 1014 "Documentation": { 1015 "Description": "Power Supply output over-current power fault", 1016 "Message": "A power supply has indicated an output over-current condition." 1017 } 1018 }, 1019 1020 { 1021 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Blackout", 1022 "Subsystem": "power", 1023 "ActionFlags": [ "report", "service_action" ], 1024 "Severity": "unrecoverable", 1025 "ComponentID": "0x2700", 1026 1027 "SRC": 1028 { 1029 "Type": "11", 1030 "ReasonCode": "0x00AC", 1031 "Words6To9": {}, 1032 "PowerFault": true 1033 }, 1034 1035 "Callouts": [ 1036 { 1037 "CalloutList": [ 1038 { "Priority": "high", "SymbolicFRU": "ac_module"} 1039 ] 1040 } 1041 ], 1042 1043 "Documentation": { 1044 "Description": "Input power was lost while the system was powered on.", 1045 "Message": "Input power was lost while the system was powered on.", 1046 "Notes": [ 1047 "Input power was lost while system powered on.", 1048 "The CalloutList should use the ACMODUL symbolic FRU." 1049 ] 1050 } 1051 }, 1052 1053 { 1054 "Name": "xyz.openbmc_project.Power.PowerSupply.Error.PSKillFault", 1055 "Subsystem": "power_supply", 1056 "Severity": "unrecoverable", 1057 "ActionFlags": ["service_action", "report", "call_home"], 1058 "ComponentID": "0x2700", 1059 1060 "SRC": { 1061 "Type": "11", 1062 "ReasonCode": "0x2500", 1063 "Words6To9": {}, 1064 "PowerFault": true 1065 }, 1066 1067 "Callouts": [ 1068 { 1069 "CalloutList": [ 1070 { "Priority": "high", "Procedure": "power_overcurrent" } 1071 ] 1072 } 1073 ], 1074 1075 "Documentation": { 1076 "Description": "A power supply fault is potentially preventing the power supply from allowing the system to power on.", 1077 "Message": "Power supply PSKill_fault", 1078 "Notes": [ 1079 ] 1080 } 1081 }, 1082 1083 { 1084 "Name": "xyz.openbmc_project.Power.Error.Shutdown", 1085 "Subsystem": "power_sequencer", 1086 "ComponentID": "0x2700", 1087 1088 "SRC": { 1089 "Type": "11", 1090 "ReasonCode": "0x2600", 1091 "Words6To9": {} 1092 }, 1093 1094 "Callouts": [ 1095 { 1096 "CalloutList": [ 1097 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1098 ] 1099 } 1100 ], 1101 1102 "Documentation": { 1103 "Description": "A power off was issued because a power fault was detected", 1104 "Message": "A power off was issued because a power fault was detected", 1105 "Notes": [ 1106 ] 1107 } 1108 }, 1109 1110 { 1111 "Name": "xyz.openbmc_project.State.Shutdown.Power.Error.Regulator", 1112 "Subsystem": "power_control_hw", 1113 "ComponentID": "0x2700", 1114 1115 "SRC": { 1116 "Type": "11", 1117 "ReasonCode": "0x2602", 1118 "Words6To9": {}, 1119 "PowerFault": true 1120 }, 1121 1122 "Callouts": [ 1123 { 1124 "System": "ibm,rainier", 1125 "CalloutList": [ 1126 { 1127 "Priority": "high", 1128 "LocCode": "P0-C5" 1129 }, 1130 { 1131 "Priority": "medium", 1132 "LocCode": "P0" 1133 } 1134 ] 1135 }, 1136 { 1137 "System": "ibm,everest", 1138 "CalloutList": [ 1139 { 1140 "Priority": "high", 1141 "LocCode": "P0-C59" 1142 }, 1143 { 1144 "Priority": "medium", 1145 "LocCode": "P0" 1146 } 1147 ] 1148 } 1149 ], 1150 1151 "Documentation": { 1152 "Description": "A power off was issued because a regulator for standby power faulted", 1153 "Message": "A power off was issued because a regulator for standby power faulted", 1154 "Notes": [ 1155 ] 1156 } 1157 }, 1158 1159 { 1160 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault", 1161 "Subsystem": "power_sequencer", 1162 "ComponentID": "0x2700", 1163 1164 "SRC": { 1165 "Type": "11", 1166 "ReasonCode": "0x2610", 1167 "Words6To9": {} 1168 }, 1169 1170 "CalloutsUsingAD": { 1171 "ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [ 1172 { 1173 "ADValue": "PCIE_SLOT0", "Callouts": [ 1174 { 1175 "CalloutList": [ 1176 { "Priority": "high", "LocCode": "P0-C0" }, 1177 { "Priority": "medium", "LocCode": "P0" } 1178 ] 1179 } 1180 ] 1181 }, 1182 { 1183 "ADValue": "PCIE_SLOT1", "Callouts": [ 1184 { 1185 "CalloutList": [ 1186 { "Priority": "high", "LocCode": "P0-C1" }, 1187 { "Priority": "medium", "LocCode": "P0" } 1188 ] 1189 } 1190 ] 1191 }, 1192 { 1193 "ADValue": "PCIE_SLOT2", "Callouts": [ 1194 { 1195 "CalloutList": [ 1196 { "Priority": "high", "LocCode": "P0-C2" }, 1197 { "Priority": "medium", "LocCode": "P0" } 1198 ] 1199 } 1200 ] 1201 }, 1202 { 1203 "ADValue": "PCIE_SLOT3", "Callouts": [ 1204 { 1205 "CalloutList": [ 1206 { "Priority": "high", "LocCode": "P0-C3" }, 1207 { "Priority": "medium", "LocCode": "P0" } 1208 ] 1209 } 1210 ] 1211 }, 1212 { 1213 "ADValue": "PCIE_SLOT4", "Callouts": [ 1214 { 1215 "CalloutList": [ 1216 { "Priority": "high", "LocCode": "P0-C4" }, 1217 { "Priority": "medium", "LocCode": "P0" } 1218 ] 1219 } 1220 ] 1221 }, 1222 { 1223 "ADValue": "PCIE_SLOT7", "Callouts": [ 1224 { 1225 "CalloutList": [ 1226 { "Priority": "high", "LocCode": "P0-C7" }, 1227 { "Priority": "medium", "LocCode": "P0" } 1228 ] 1229 } 1230 ] 1231 }, 1232 { 1233 "ADValue": "PCIE_SLOT8", "Callouts": [ 1234 { 1235 "CalloutList": [ 1236 { "Priority": "high", "LocCode": "P0-C8" }, 1237 { "Priority": "medium", "LocCode": "P0" } 1238 ] 1239 } 1240 ] 1241 }, 1242 { 1243 "ADValue": "PCIE_SLOT9", "Callouts": [ 1244 { 1245 "CalloutList": [ 1246 { "Priority": "high", "LocCode": "P0-C9" }, 1247 { "Priority": "medium", "LocCode": "P0" } 1248 ] 1249 } 1250 ] 1251 }, 1252 { 1253 "ADValue": "PCIE_SLOT10", "Callouts": [ 1254 { 1255 "CalloutList": [ 1256 { "Priority": "high", "LocCode": "P0-C10" }, 1257 { "Priority": "medium", "LocCode": "P0" } 1258 ] 1259 } 1260 ] 1261 }, 1262 { 1263 "ADValue": "PCIE_SLOT11", "Callouts": [ 1264 { 1265 "CalloutList": [ 1266 { "Priority": "high", "LocCode": "P0-C11" }, 1267 { "Priority": "medium", "LocCode": "P0" } 1268 ] 1269 } 1270 ] 1271 }, 1272 { 1273 "ADValue": "PGOOD_12A", "Callouts": [ 1274 { 1275 "CalloutList": [ 1276 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1277 ] 1278 } 1279 ] 1280 }, 1281 { 1282 "ADValue": "PGOOD_12B", "Callouts": [ 1283 { 1284 "CalloutList": [ 1285 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1286 ] 1287 } 1288 ] 1289 }, 1290 { 1291 "ADValue": "PGOOD_12C", "Callouts": [ 1292 { 1293 "CalloutList": [ 1294 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1295 ] 1296 } 1297 ] 1298 }, 1299 { 1300 "ADValue": "PGOOD_12D", "Callouts": [ 1301 { 1302 "CalloutList": [ 1303 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1304 ] 1305 } 1306 ] 1307 }, 1308 { 1309 "ADValue": "PGOOD_12L", "Callouts": [ 1310 { 1311 "CalloutList": [ 1312 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1313 ] 1314 } 1315 ] 1316 }, 1317 { 1318 "ADValue": "PGOOD_12M", "Callouts": [ 1319 { 1320 "CalloutList": [ 1321 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1322 ] 1323 } 1324 ] 1325 }, 1326 { 1327 "ADValue": "PGOOD_12N", "Callouts": [ 1328 { 1329 "CalloutList": [ 1330 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1331 ] 1332 } 1333 ] 1334 }, 1335 { 1336 "ADValue": "PGOOD_12P", "Callouts": [ 1337 { 1338 "CalloutList": [ 1339 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1340 ] 1341 } 1342 ] 1343 }, 1344 { 1345 "ADValue": "PGOOD_12PCIE", "Callouts": [ 1346 { 1347 "CalloutList": [ 1348 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1349 ] 1350 } 1351 ] 1352 }, 1353 { 1354 "ADValue": "PGOOD_12Q", "Callouts": [ 1355 { 1356 "CalloutList": [ 1357 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1358 ] 1359 } 1360 ] 1361 }, 1362 { 1363 "ADValue": "PGOOD_12R", "Callouts": [ 1364 { 1365 "CalloutList": [ 1366 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1367 ] 1368 } 1369 ] 1370 }, 1371 { 1372 "ADValue": "PGOOD_VDN_DCM0", "Callouts": [ 1373 { 1374 "CalloutList": [ 1375 { "Priority": "high", "LocCode": "P0-C14" }, 1376 { "Priority": "medium", "LocCode": "P0-C15" }, 1377 { "Priority": "low", "LocCode": "P0" } 1378 ] 1379 } 1380 ] 1381 }, 1382 { 1383 "ADValue": "PGOOD_VDN_DCM1", "Callouts": [ 1384 { 1385 "CalloutList": [ 1386 { "Priority": "high", "LocCode": "P0-C23" }, 1387 { "Priority": "medium", "LocCode": "P0-C24" }, 1388 { "Priority": "low", "LocCode": "P0" } 1389 ] 1390 } 1391 ] 1392 }, 1393 { 1394 "ADValue": "PGOOD_VCS_DCM0", "Callouts": [ 1395 { 1396 "CalloutList": [ 1397 { "Priority": "high", "LocCode": "P0-C14" }, 1398 { "Priority": "medium", "LocCode": "P0-C15" }, 1399 { "Priority": "low", "LocCode": "P0" } 1400 ] 1401 } 1402 ] 1403 }, 1404 { 1405 "ADValue": "PGOOD_VCS_DCM1", "Callouts": [ 1406 { 1407 "CalloutList": [ 1408 { "Priority": "high", "LocCode": "P0-C23" }, 1409 { "Priority": "medium", "LocCode": "P0-C24" }, 1410 { "Priority": "low", "LocCode": "P0" } 1411 ] 1412 } 1413 ] 1414 }, 1415 { 1416 "ADValue": "PGOOD_VIO_DCM0", "Callouts": [ 1417 { 1418 "CalloutList": [ 1419 { "Priority": "high", "LocCode": "P0-C14" }, 1420 { "Priority": "medium", "LocCode": "P0-C15" }, 1421 { "Priority": "low", "LocCode": "P0" } 1422 ] 1423 } 1424 ] 1425 }, 1426 { 1427 "ADValue": "PGOOD_VIO_DCM1", "Callouts": [ 1428 { 1429 "CalloutList": [ 1430 { "Priority": "high", "LocCode": "P0-C23" }, 1431 { "Priority": "medium", "LocCode": "P0-C24" }, 1432 { "Priority": "low", "LocCode": "P0" } 1433 ] 1434 } 1435 ] 1436 }, 1437 { 1438 "ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [ 1439 { 1440 "CalloutList": [ 1441 { "Priority": "high", "LocCode": "P0-C14" }, 1442 { "Priority": "medium", "LocCode": "P0-C15" }, 1443 { "Priority": "low", "LocCode": "P0" } 1444 ] 1445 } 1446 ] 1447 }, 1448 { 1449 "ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [ 1450 { 1451 "CalloutList": [ 1452 { "Priority": "high", "LocCode": "P0-C23" }, 1453 { "Priority": "medium", "LocCode": "P0-C24" }, 1454 { "Priority": "low", "LocCode": "P0" } 1455 ] 1456 } 1457 ] 1458 } 1459 ] 1460 }, 1461 1462 "Documentation": { 1463 "Description": "The power sequencer chip detected a PGOOD fault", 1464 "Message": "The power sequencer chip detected a PGOOD fault", 1465 "Notes": [ 1466 ] 1467 } 1468 }, 1469 1470 { 1471 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault", 1472 "Subsystem": "power_sequencer", 1473 "ComponentID": "0x2700", 1474 1475 "SRC": { 1476 "Type": "11", 1477 "ReasonCode": "0x2620", 1478 "Words6To9": {} 1479 }, 1480 1481 "CalloutsUsingAD": { 1482 "ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [ 1483 { 1484 "ADValue": "12.0V", "Callouts": [ 1485 { 1486 "CalloutList": [ 1487 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1488 ] 1489 } 1490 ] 1491 }, 1492 { 1493 "ADValue": "5.0V_USB", "Callouts": [ 1494 { 1495 "CalloutList": [ 1496 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1497 { "Priority": "medium", "LocCode": "P0" } 1498 ] 1499 } 1500 ] 1501 }, 1502 { 1503 "ADValue": "5.0V_DASD", "Callouts": [ 1504 { 1505 "CalloutList": [ 1506 { "Priority": "medium", "LocCode": "P1" }, 1507 { "Priority": "medium", "LocCode": "P2" }, 1508 { "Priority": "medium", "LocCode": "P3" }, 1509 { "Priority": "low", "LocCode": "P0" } 1510 ] 1511 } 1512 ] 1513 }, 1514 { 1515 "ADValue": "3.3VA", "Callouts": [ 1516 { 1517 "CalloutList": [ 1518 { "Priority": "high", "LocCode": "P0" } 1519 ] 1520 } 1521 ] 1522 }, 1523 { 1524 "ADValue": "3.3VB", "Callouts": [ 1525 { 1526 "CalloutList": [ 1527 { "Priority": "high", "LocCode": "P0" } 1528 ] 1529 } 1530 ] 1531 }, 1532 { 1533 "ADValue": "1.5V", "Callouts": [ 1534 { 1535 "CalloutList": [ 1536 { "Priority": "high", "LocCode": "P0" } 1537 ] 1538 } 1539 ] 1540 }, 1541 { 1542 "ADValue": "1.1V", "Callouts": [ 1543 { 1544 "CalloutList": [ 1545 { "Priority": "high", "LocCode": "P0" } 1546 ] 1547 } 1548 ] 1549 }, 1550 { 1551 "ADValue": "VDDA_DCM0", "Callouts": [ 1552 { 1553 "CalloutList": [ 1554 { "Priority": "high", "LocCode": "P0-C14" }, 1555 { "Priority": "medium", "LocCode": "P0-C15" }, 1556 { "Priority": "low", "LocCode": "P0" } 1557 ] 1558 } 1559 ] 1560 }, 1561 { 1562 "ADValue": "VDDB_DCM0", "Callouts": [ 1563 { 1564 "CalloutList": [ 1565 { "Priority": "high", "LocCode": "P0-C14" }, 1566 { "Priority": "medium", "LocCode": "P0-C15" }, 1567 { "Priority": "low", "LocCode": "P0" } 1568 ] 1569 } 1570 ] 1571 }, 1572 { 1573 "ADValue": "VDDA_DCM1", "Callouts": [ 1574 { 1575 "CalloutList": [ 1576 { "Priority": "high", "LocCode": "P0-C23" }, 1577 { "Priority": "medium", "LocCode": "P0-C24" }, 1578 { "Priority": "low", "LocCode": "P0" } 1579 ] 1580 } 1581 ] 1582 }, 1583 { 1584 "ADValue": "VDDB_DCM1", "Callouts": [ 1585 { 1586 "CalloutList": [ 1587 { "Priority": "high", "LocCode": "P0-C23" }, 1588 { "Priority": "medium", "LocCode": "P0-C24" }, 1589 { "Priority": "low", "LocCode": "P0" } 1590 ] 1591 } 1592 ] 1593 }, 1594 { 1595 "ADValue": "12.0VCS", "Callouts": [ 1596 { 1597 "CalloutList": [ 1598 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1599 ] 1600 } 1601 ] 1602 }, 1603 { 1604 "ADValue": "3.3VCS", "Callouts": [ 1605 { 1606 "CalloutList": [ 1607 { "Priority": "high", "LocCode": "P0" } 1608 ] 1609 } 1610 ] 1611 }, 1612 { 1613 "ADValue": "1.1V_Current", "Callouts": [ 1614 { 1615 "CalloutList": [ 1616 { "Priority": "high", "LocCode": "P0" } 1617 ] 1618 } 1619 ] 1620 }, 1621 { 1622 "ADValue": "5.0V_USB_Current", "Callouts": [ 1623 { 1624 "CalloutList": [ 1625 { "Priority": "high", "SymbolicFRU": "usb_pgood" }, 1626 { "Priority": "medium", "LocCode": "P0" } 1627 ] 1628 } 1629 ] 1630 }, 1631 { 1632 "ADValue": "5.0V_DASD_Current", "Callouts": [ 1633 { 1634 "CalloutList": [ 1635 { "Priority": "medium", "LocCode": "P1" }, 1636 { "Priority": "medium", "LocCode": "P2" }, 1637 { "Priority": "medium", "LocCode": "P3" }, 1638 { "Priority": "low", "LocCode": "P0" } 1639 ] 1640 } 1641 ] 1642 }, 1643 { 1644 "ADValue": "12.0VN", "Callouts": [ 1645 { 1646 "CalloutList": [ 1647 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1648 ] 1649 } 1650 ] 1651 }, 1652 { 1653 "ADValue": "12.0VP", "Callouts": [ 1654 { 1655 "CalloutList": [ 1656 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1657 ] 1658 } 1659 ] 1660 }, 1661 { 1662 "ADValue": "12.0VQ", "Callouts": [ 1663 { 1664 "CalloutList": [ 1665 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1666 ] 1667 } 1668 ] 1669 }, 1670 { 1671 "ADValue": "12.0VR", "Callouts": [ 1672 { 1673 "CalloutList": [ 1674 { "Priority": "high", "SymbolicFRU": "pgood_part" } 1675 ] 1676 } 1677 ] 1678 }, 1679 { 1680 "ADValue": "ThermalDiode1", "Callouts": [ 1681 { 1682 "CalloutList": [ 1683 { "Priority": "high", "LocCode": "P0" } 1684 ] 1685 } 1686 ] 1687 }, 1688 { 1689 "ADValue": "ThermalDiode2", "Callouts": [ 1690 { 1691 "CalloutList": [ 1692 { "Priority": "high", "LocCode": "P0" } 1693 ] 1694 } 1695 ] 1696 }, 1697 { 1698 "ADValue": "ThermalDiode3", "Callouts": [ 1699 { 1700 "CalloutList": [ 1701 { "Priority": "high", "LocCode": "P0" } 1702 ] 1703 } 1704 ] 1705 }, 1706 { 1707 "ADValue": "ThermalDiode4", "Callouts": [ 1708 { 1709 "CalloutList": [ 1710 { "Priority": "high", "LocCode": "P0" } 1711 ] 1712 } 1713 ] 1714 } 1715 ] 1716 }, 1717 1718 "Documentation": { 1719 "Description": "The power sequencer chip detected a voltage fault", 1720 "Message": "The power sequencer chip detected a voltage fault", 1721 "Notes": [ 1722 ] 1723 } 1724 }, 1725 1726 { 1727 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.N", 1728 "Subsystem": "power", 1729 "Severity": "predictive_redundancy_loss", 1730 "ComponentID": "0x2700", 1731 1732 "SRC": { 1733 "Type": "11", 1734 "ReasonCode": "0x2700", 1735 "Words6To9": {} 1736 }, 1737 1738 "Documentation": { 1739 "Description": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1740 "Message": "Voltage regulator phase fault detected; device now at redundancy level N (no redundant phases)", 1741 "Notes": [ 1742 "CALLOUT_INVENTORY_PATH should be specified in the ", 1743 "AdditionalData property of the event log so that ", 1744 "the device is called out but not the communication path." 1745 ] 1746 } 1747 }, 1748 1749 { 1750 "Name": "xyz.openbmc_project.Power.Regulators.Error.PhaseFault.NPlus1", 1751 "Subsystem": "power", 1752 "Severity": "non_error", 1753 "MfgSeverity": "predictive_redundancy_loss", 1754 "ActionFlags": ["report"], 1755 "MfgActionFlags": ["service_action", "report", "call_home"], 1756 "ComponentID": "0x2700", 1757 1758 "SRC": { 1759 "Type": "11", 1760 "ReasonCode": "0x2701", 1761 "Words6To9": {} 1762 }, 1763 1764 "Documentation": { 1765 "Description": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1766 "Message": "Voltage regulator phase fault detected; device now at redundancy level N+1 (one redundant phase)", 1767 "Notes": [ 1768 "CALLOUT_INVENTORY_PATH should be specified in the ", 1769 "AdditionalData property of the event log so that ", 1770 "the device is called out but not the communication path." 1771 ] 1772 } 1773 }, 1774 1775 { 1776 "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", 1777 "Subsystem": "power", 1778 "ComponentID": "0x2700", 1779 1780 "SRC": { 1781 "Type": "11", 1782 "ReasonCode": "0x2900", 1783 "Words6To9": {} 1784 }, 1785 1786 "Documentation": { 1787 "Description": "A write verification error occurred on a device", 1788 "Message": "A write verification error occurred on a device", 1789 "Notes": [ 1790 "This error occurs when a device register is written, ", 1791 "read back, and the two values do not match. This is ", 1792 "also called a read-back error. The device should be ", 1793 "identified using the CALLOUT_DEVICE_PATH or ", 1794 "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", 1795 "AdditionalData property of the event log. This will ", 1796 "cause the device and the hardware in the communication ", 1797 "path to be called out." 1798 ] 1799 } 1800 }, 1801 1802 { 1803 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", 1804 "Subsystem": "power", 1805 "ComponentID": "0x2700", 1806 1807 "SRC": { 1808 "Type": "11", 1809 "ReasonCode": "0xA013", 1810 "Words6To9": {} 1811 }, 1812 1813 "Callouts": [ 1814 { 1815 "CalloutList": [ 1816 { "Priority": "high", "Procedure": "bmc_code" } 1817 ] 1818 } 1819 ], 1820 1821 "Documentation": { 1822 "Description": "A regulators configuration file error occurred", 1823 "Message": "A regulators configuration file error occurred", 1824 "Notes": [ 1825 "The regulators configuration file could not be found, ", 1826 "could not be read, or had invalid contents." 1827 ] 1828 } 1829 }, 1830 1831 { 1832 "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile.Critical", 1833 "Subsystem": "power", 1834 "Severity": "critical_system_term", 1835 "ComponentID": "0x2700", 1836 1837 "SRC": { 1838 "Type": "11", 1839 "ReasonCode": "0xA014", 1840 "Words6To9": {}, 1841 "PowerFault": true 1842 }, 1843 1844 "Callouts": [ 1845 { 1846 "CalloutList": [ 1847 { "Priority": "high", "Procedure": "bmc_code" } 1848 ] 1849 } 1850 ], 1851 1852 "Documentation": { 1853 "Description": "A critical regulators configuration file error occurred", 1854 "Message": "A critical regulators configuration file error occurred", 1855 "Notes": [ 1856 "The regulators configuration file could not be found, ", 1857 "could not be read, or had invalid contents. As a result ", 1858 "voltage regulators could not be configured, and the ", 1859 "chassis could not be powered on." 1860 ] 1861 } 1862 }, 1863 1864 { 1865 "Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault", 1866 "Subsystem": "power_sequencer", 1867 "ComponentID": "0x2700", 1868 1869 "SRC": { 1870 "Type": "11", 1871 "ReasonCode": "0xD000", 1872 "Words6To9": {} 1873 }, 1874 1875 "Callouts": [ 1876 { 1877 "CalloutList": [ 1878 { "Priority": "high", "LocCode": "P0" } 1879 ] 1880 } 1881 ], 1882 1883 "Documentation": { 1884 "Description": "The power sequencer chip detected a fault", 1885 "Message": "The power sequencer chip detected a fault", 1886 "Notes": [ 1887 ] 1888 } 1889 }, 1890 1891 { 1892 "Name": "xyz.openbmc_project.Power.Error.PowerOnTimeout", 1893 "Subsystem": "power_sequencer", 1894 "ComponentID": "0x2700", 1895 "Severity": "critical", 1896 1897 "SRC": { 1898 "Type": "11", 1899 "ReasonCode": "0xD002", 1900 "Words6To9": {} 1901 }, 1902 1903 "Callouts": [ 1904 { 1905 "CalloutList": [ 1906 { "Priority": "high", "LocCode": "P0" } 1907 ] 1908 } 1909 ], 1910 1911 "Documentation": { 1912 "Description": "System power failed to turn on within timeout period", 1913 "Message": "System power failed to turn on within timeout period", 1914 "Notes": [ 1915 ] 1916 } 1917 }, 1918 1919 { 1920 "Name": "xyz.openbmc_project.Power.Error.PowerOffTimeout", 1921 "Subsystem": "power_sequencer", 1922 "ComponentID": "0x2700", 1923 "Severity": "critical", 1924 1925 "SRC": { 1926 "Type": "11", 1927 "ReasonCode": "0xD008", 1928 "Words6To9": {} 1929 }, 1930 1931 "Callouts": [ 1932 { 1933 "CalloutList": [ 1934 { "Priority": "high", "LocCode": "P0" } 1935 ] 1936 } 1937 ], 1938 1939 "Documentation": { 1940 "Description": "System power failed to turn off within timeout period", 1941 "Message": "System power failed to turn off within timeout period", 1942 "Notes": [ 1943 ] 1944 } 1945 }, 1946 1947 { 1948 "Name": "xyz.openbmc_project.Power.Error.Internal", 1949 "Subsystem": "power", 1950 "ComponentID": "0x2700", 1951 1952 "SRC": { 1953 "Type": "11", 1954 "ReasonCode": "0xE000", 1955 "Words6To9": {} 1956 }, 1957 1958 "Callouts": [ 1959 { 1960 "CalloutList": [ 1961 { "Priority": "high", "Procedure": "bmc_code" } 1962 ] 1963 } 1964 ], 1965 1966 "Documentation": { 1967 "Description": "An internal firmware error occurred", 1968 "Message": "An internal firmware error occurred", 1969 "Notes": [ 1970 "The error details must be provided in the AdditionalData ", 1971 "property of the event log." 1972 ] 1973 } 1974 }, 1975 1976 { 1977 "Name": "xyz.openbmc_project.Power.Error.I2C", 1978 "Subsystem": "cec_i2c", 1979 "ComponentID": "0x2700", 1980 1981 "SRC": { 1982 "Type": "11", 1983 "ReasonCode": "0xE100", 1984 "Words6To9": {} 1985 }, 1986 1987 "Documentation": { 1988 "Description": "An I2C error occurred communicating with a device", 1989 "Message": "An I2C error occurred communicating with a device", 1990 "Notes": [ 1991 "The device should be identified using the ", 1992 "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", 1993 "keywords in the AdditionalData property of the event ", 1994 "log. This will cause the device and the hardware in the ", 1995 "communication path to be called out." 1996 ] 1997 } 1998 }, 1999 2000 { 2001 "Name": "xyz.openbmc_project.Power.Error.PMBus", 2002 "Subsystem": "power", 2003 "ComponentID": "0x2700", 2004 2005 "SRC": { 2006 "Type": "11", 2007 "ReasonCode": "0xE200", 2008 "Words6To9": {} 2009 }, 2010 2011 "Documentation": { 2012 "Description": "A PMBus error occurred on a device", 2013 "Message": "A PMBus error occurred on a device", 2014 "Notes": [ 2015 "This error occurs when the I2C communication was ", 2016 "successful, but the PMBus value read is invalid or ", 2017 "unsupported. CALLOUT_INVENTORY_PATH should be specified ", 2018 "in the AdditionalData property of the event log so that ", 2019 "the device is called out but not the communication path." 2020 ] 2021 } 2022 }, 2023 2024 { 2025 "Name": "xyz.openbmc_project.Power.Error.DBus", 2026 "Subsystem": "power", 2027 "ComponentID": "0x2700", 2028 2029 "SRC": { 2030 "Type": "11", 2031 "ReasonCode": "0xE300", 2032 "Words6To9": {} 2033 }, 2034 2035 "Callouts": [ 2036 { 2037 "CalloutList": [ 2038 { "Priority": "high", "Procedure": "bmc_code" } 2039 ] 2040 } 2041 ], 2042 2043 "Documentation": { 2044 "Description": "A firmware inter-process communication (D-Bus) error occurred", 2045 "Message": "A firmware inter-process communication (D-Bus) error occurred" 2046 } 2047 }, 2048 2049 { 2050 "Name": "xyz.openbmc_project.Fan.Error.Fault", 2051 "Subsystem": "power_fans", 2052 "ComponentID": "0x2800", 2053 2054 "SRC": { 2055 "Type": "11", 2056 "ReasonCode": "0x76F0", 2057 "Words6To9": {} 2058 }, 2059 2060 "Documentation": { 2061 "Description": "Fan rotor fault", 2062 "Message": "Fan rotor fault", 2063 "Notes": [ 2064 "This error occurs when a fan rotor has been faulted for a ", 2065 "certain amount of time. The callout is the fan which is ", 2066 "passed in with CALLOUT_INVENTORY_PATH. The severity is ", 2067 "passed in during creation and will be either informational ", 2068 "or unrecoverable. The action flags use the defaults and ", 2069 "vary based on the severity." 2070 ] 2071 } 2072 }, 2073 2074 { 2075 "Name": "xyz.openbmc_project.Fan.Error.Missing", 2076 "Subsystem": "power_fans", 2077 "ComponentID": "0x2800", 2078 "Severity": "unrecoverable_redundancy_loss", 2079 "ActionFlags": ["service_action", "report", "call_home"], 2080 2081 "SRC": { 2082 "Type": "11", 2083 "ReasonCode": "0x76F1", 2084 "Words6To9": {} 2085 }, 2086 2087 "Callouts": [ 2088 { 2089 "System": "ibm,rainier", 2090 "CalloutList": [ 2091 { 2092 "Priority": "high", 2093 "SymbolicFRUTrusted": "air_mover", 2094 "UseInventoryLocCode": true 2095 }, 2096 { 2097 "Priority": "low", 2098 "LocCode": "P0" 2099 } 2100 ] 2101 }, 2102 { 2103 "System": "ibm,everest", 2104 "CalloutList": [ 2105 { 2106 "Priority": "high", 2107 "SymbolicFRUTrusted": "air_mover", 2108 "UseInventoryLocCode": true 2109 }, 2110 { 2111 "Priority": "low", 2112 "LocCode": "P1" 2113 } 2114 ] 2115 } 2116 ], 2117 2118 "Documentation": { 2119 "Description": "A fan is missing", 2120 "Message": "A fan is missing", 2121 "Notes": [ 2122 "This error occurs when a fan has been missing for a ", 2123 "certain amount of time. The first callout is the ", 2124 "symbolic FRU AIR_MOVR that has the trusted fan location ", 2125 "code, which it gets using the passed in ", 2126 "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", 2127 "where the controller and GPIO expander are." 2128 ] 2129 } 2130 }, 2131 2132 { 2133 "Name": "xyz.openbmc_project.Fan.Presence.Error.Detection", 2134 "ComponentID": "0x2800", 2135 "Subsystem": "power_fans", 2136 "Severity": "non_error", 2137 "ActionFlags": ["report"], 2138 "MfgSeverity": "predictive", 2139 "MfgActionFlags": ["service_action", "report"], 2140 2141 "SRC": { 2142 "Type": "11", 2143 "ReasonCode": "0x76F2", 2144 "Words6To9": {} 2145 }, 2146 2147 "Callouts": [ 2148 { 2149 "System": "ibm,rainier", 2150 "CalloutList": [ 2151 {"Priority": "medium", "LocCode": "P0"} 2152 ] 2153 }, 2154 { 2155 "System": "ibm,everest", 2156 "CalloutList": [ 2157 {"Priority": "medium", "LocCode": "P1"} 2158 ] 2159 } 2160 ], 2161 2162 "Documentation": { 2163 "Description": "Presence detect methods for the same fan disagree", 2164 "Message": "Presence detect methods for the same fan disagree", 2165 "Notes": [ 2166 "This error occurs when there is more than one way to detect", 2167 "fan presence, and they don't all agree. For example, the", 2168 "GPIO says a fan isn't present, but the tach readings are", 2169 "nonzero. This is informational, unless in manufacturing.", 2170 "The fan FRU is passed in as a high priority callout.", 2171 "The FRU the GPIO source is on is called out medium." 2172 ] 2173 } 2174 }, 2175 2176 { 2177 "Name": "xyz.openbmc_project.Fan.Error.FanControllerOffline", 2178 "ComponentID": "0x2800", 2179 "Subsystem": "power_fans", 2180 "Severity": "critical_system_term", 2181 "ActionFlags": ["service_action", "report", "call_home"], 2182 2183 "SRC": { 2184 "Type": "11", 2185 "ReasonCode": "0x76F3", 2186 "Words6To9": {}, 2187 "PowerFault": true 2188 }, 2189 2190 "Callouts": [ 2191 { 2192 "System": "ibm,rainier", 2193 "CalloutList": [ 2194 {"Priority": "high", "LocCode": "P0-C5"}, 2195 {"Priority": "medium_group_a", "LocCode": "P0-T12", "SymbolicFRUTrusted": "fan_cable"}, 2196 {"Priority": "medium_group_a", "LocCode": "P0-T17", "SymbolicFRUTrusted": "cable_continued"}, 2197 {"Priority": "low", "LocCode": "P0"} 2198 ] 2199 }, 2200 { 2201 "System": "ibm,everest", 2202 "CalloutList": [ 2203 {"Priority": "high", "LocCode": "P0-C0"}, 2204 {"Priority": "medium", "LocCode": "P1"}, 2205 {"Priority": "low", "LocCode": "P0"} 2206 ] 2207 } 2208 ], 2209 2210 "Documentation": { 2211 "Description": "The fan controller device is offline", 2212 "Message": "The fan controller is offline. The system must be powered off.", 2213 "Notes": [ 2214 "The device that controls the fans is offline so the fan", 2215 "targets and speeds are unknown. The system will be shut", 2216 "down to preserve thermal safety. There may be an I2C", 2217 "or power problem with the device." 2218 ] 2219 } 2220 }, 2221 2222 { 2223 "Name": "xyz.openbmc_project.Fan.Presence.Error.GPIODeviceUnavailable", 2224 "Subsystem": "power_fans", 2225 "ComponentID": "0x2800", 2226 "Severity": "unrecoverable_redundancy_loss", 2227 "ActionFlags": ["service_action", "report", "call_home"], 2228 2229 "SRC": { 2230 "Type": "11", 2231 "ReasonCode": "0x76F4", 2232 "Words6To9": {} 2233 }, 2234 2235 "Callouts": [ 2236 { 2237 "System" : "ibm,rainier", 2238 "CalloutList": [ 2239 {"Priority": "high", "LocCode": "P0-C5"}, 2240 {"Priority": "medium_group_a", "LocCode": "P0-T12","SymbolicFRUTrusted": "fan_cable"}, 2241 {"Priority": "medium_group_a", "LocCode": "P0-T17","SymbolicFRUTrusted": "cable_continued"}, 2242 {"Priority": "low", "LocCode": "P0"} 2243 ] 2244 }, 2245 { 2246 "System" : "ibm,everest", 2247 "CalloutList": [ 2248 {"Priority": "high", "LocCode": "P0-C0"}, 2249 {"Priority": "medium", "LocCode": "P1"}, 2250 {"Priority": "low", "LocCode": "P0"} 2251 ] 2252 } 2253 ], 2254 2255 "Documentation": { 2256 "Description": "Fan GPIO sensors not present", 2257 "Message": "Fan GPIO sensors not present", 2258 "Notes": [ 2259 "The device that reports fan presence is not functioning." 2260 ] 2261 } 2262 }, 2263 2264 { 2265 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHigh", 2266 "Subsystem": "power", 2267 "ComponentID": "0x2800", 2268 "Severity": "predictive", 2269 "ActionFlags": ["service_action", "report"], 2270 2271 "SRC": { 2272 "ReasonCode": "0x2801", 2273 "Words6To9": {} 2274 }, 2275 2276 "CalloutsUsingAD": { 2277 "ADName": "SENSOR_NAME", 2278 "CalloutsWithTheirADValues": [ 2279 { 2280 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2281 "Callouts": [ 2282 { 2283 "CalloutList": [ 2284 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2285 ] 2286 } 2287 ] 2288 } 2289 ] 2290 }, 2291 2292 "Documentation": { 2293 "Description": "A temperature sensor exceeded its performance loss threshold.", 2294 "Message": "A temperature sensor exceeded its performance loss threshold.", 2295 "Notes": [ 2296 "A temperature sensor crossed its performance loss threshold value", 2297 "If it is the ambient sensor, then a symbolic FRU will be added.", 2298 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2299 "a FRU callout." 2300 ] 2301 } 2302 }, 2303 2304 { 2305 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperaturePerfLossHighClear", 2306 "Subsystem": "power", 2307 "ComponentID": "0x2800", 2308 "Severity": "non_error", 2309 "ActionFlags": ["report"], 2310 "EventType": "env_normal", 2311 2312 "SRC": { 2313 "ReasonCode": "0x2802", 2314 "Words6To9": {} 2315 }, 2316 2317 "CalloutsUsingAD": { 2318 "ADName": "SENSOR_NAME", 2319 "CalloutsWithTheirADValues": [ 2320 { 2321 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2322 "Callouts": [ 2323 { 2324 "CalloutList": [ 2325 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2326 ] 2327 } 2328 ] 2329 } 2330 ] 2331 }, 2332 2333 "Documentation": { 2334 "Description": "A temperature sensor is under its performance loss threshold.", 2335 "Message": "A temperature sensor is under its performance loss threshold.", 2336 "Notes": [ 2337 "A temperature sensor crossed under its performance loss threshold value", 2338 "If it is the ambient sensor, then a symbolic FRU will be added." 2339 ] 2340 } 2341 }, 2342 2343 { 2344 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHigh", 2345 "Subsystem": "power", 2346 "ComponentID": "0x2800", 2347 "Severity": "predictive", 2348 "ActionFlags": ["service_action", "report"], 2349 2350 "SRC": { 2351 "ReasonCode": "0x2803", 2352 "Words6To9": {} 2353 }, 2354 2355 "CalloutsUsingAD": { 2356 "ADName": "SENSOR_NAME", 2357 "CalloutsWithTheirADValues": [ 2358 { 2359 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2360 "Callouts": [ 2361 { 2362 "CalloutList": [ 2363 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2364 ] 2365 } 2366 ] 2367 } 2368 ] 2369 }, 2370 2371 "Documentation": { 2372 "Description": "A temperature sensor exceeded its warning threshold.", 2373 "Message": "A temperature sensor exceeded its warning threshold.", 2374 "Notes": [ 2375 "A temperature sensor crossed its warning threshold value", 2376 "If it is the ambient sensor, then a symbolic FRU will be added.", 2377 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2378 "a FRU callout." 2379 ] 2380 } 2381 }, 2382 2383 { 2384 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningHighClear", 2385 "Subsystem": "power", 2386 "ComponentID": "0x2800", 2387 "Severity": "non_error", 2388 "ActionFlags": ["report"], 2389 "EventType": "env_normal", 2390 2391 "SRC": { 2392 "ReasonCode": "0x2804", 2393 "Words6To9": {} 2394 }, 2395 2396 "CalloutsUsingAD": { 2397 "ADName": "SENSOR_NAME", 2398 "CalloutsWithTheirADValues": [ 2399 { 2400 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2401 "Callouts": [ 2402 { 2403 "CalloutList": [ 2404 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2405 ] 2406 } 2407 ] 2408 } 2409 ] 2410 }, 2411 2412 "Documentation": { 2413 "Description": "A temperature sensor is under its warning threshold.", 2414 "Message": "A temperature sensor is under its warning threshold.", 2415 "Notes": [ 2416 "A temperature sensor crossed under its warning threshold value", 2417 "If it is the ambient sensor, then a symbolic FRU will be added." 2418 ] 2419 } 2420 }, 2421 2422 { 2423 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHigh", 2424 "Subsystem": "power", 2425 "ComponentID": "0x2800", 2426 "Severity": "predictive", 2427 "ActionFlags": ["service_action", "report"], 2428 2429 "SRC": { 2430 "ReasonCode": "0x2805", 2431 "Words6To9": {} 2432 }, 2433 2434 "CalloutsUsingAD": { 2435 "ADName": "SENSOR_NAME", 2436 "CalloutsWithTheirADValues": [ 2437 { 2438 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2439 "Callouts": [ 2440 { 2441 "CalloutList": [ 2442 { "Priority": "high", "SymbolicFRU": "ambient_temp" } 2443 ] 2444 } 2445 ] 2446 } 2447 ] 2448 }, 2449 2450 "Documentation": { 2451 "Description": "A temperature sensor exceeded its critical threshold.", 2452 "Message": "A temperature sensor exceeded its critical threshold.", 2453 "Notes": [ 2454 "A temperature sensor crossed its critical threshold value", 2455 "If it is the ambient sensor, then a symbolic FRU will be added.", 2456 "Otherwise, CALLOUT_INVENTORY_PATH will be passed in to add", 2457 "a FRU callout." 2458 ] 2459 } 2460 }, 2461 2462 { 2463 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalHighClear", 2464 "Subsystem": "power", 2465 "ComponentID": "0x2800", 2466 "Severity": "non_error", 2467 "ActionFlags": ["report"], 2468 "EventType": "env_normal", 2469 2470 "SRC": { 2471 "ReasonCode": "0x2806", 2472 "Words6To9": {} 2473 }, 2474 2475 "CalloutsUsingAD": { 2476 "ADName": "SENSOR_NAME", 2477 "CalloutsWithTheirADValues": [ 2478 { 2479 "ADValue": "/xyz/openbmc_project/sensors/temperature/Ambient_Virtual_Temp", 2480 "Callouts": [ 2481 { 2482 "CalloutList": [ 2483 { "Priority": "high", "SymbolicFRU": "ambient_temp_back" } 2484 ] 2485 } 2486 ] 2487 } 2488 ] 2489 }, 2490 2491 "Documentation": { 2492 "Description": "A temperature sensor is under its critical threshold.", 2493 "Message": "A temperature sensor is under its critical threshold.", 2494 "Notes": [ 2495 "A temperature sensor crossed under its critical threshold value", 2496 "If it is the ambient sensor, then a symbolic FRU will be added." 2497 ] 2498 } 2499 }, 2500 2501 { 2502 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHigh", 2503 "Subsystem": "power", 2504 "ComponentID": "0x2800", 2505 "Severity": "predictive", 2506 "ActionFlags": ["service_action", "report"], 2507 2508 "SRC": { 2509 "ReasonCode": "0x2807", 2510 "Words6To9": {} 2511 }, 2512 2513 "Callouts": [ 2514 { 2515 "CalloutList": [ 2516 { 2517 "Priority": "high", 2518 "SymbolicFRU": "ambient_temp" 2519 } 2520 ] 2521 } 2522 ], 2523 2524 "Documentation": { 2525 "Description": "The ambient temperature passed the EPOW3 limit.", 2526 "Message": "The ambient temperature passed the EPOW3 limit. The system will shut down if temp doesn't decrease.", 2527 "Notes": [ 2528 "This error occurs when the ambient temperature surpassed", 2529 "the EPOW3 shutdown limit." 2530 ] 2531 } 2532 }, 2533 2534 { 2535 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.SoftShutdownAlarmHighClear", 2536 "Subsystem": "power", 2537 "ComponentID": "0x2800", 2538 "Severity": "non_error", 2539 "ActionFlags": ["report"], 2540 "EventType": "env_normal", 2541 2542 "SRC": { 2543 "ReasonCode": "0x2808", 2544 "Words6To9": {} 2545 }, 2546 2547 "Callouts": [ 2548 { 2549 "CalloutList": [ 2550 { 2551 "Priority": "high", 2552 "SymbolicFRU": "ambient_temp_back" 2553 } 2554 ] 2555 } 2556 ], 2557 2558 "Documentation": { 2559 "Description": "The ambient temperature is back under the EPOW3 limit.", 2560 "Message": "The ambient temperature is back under the EPOW3 limit." 2561 } 2562 }, 2563 2564 { 2565 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.HardShutdownAlarmHigh", 2566 "Subsystem": "power", 2567 "ComponentID": "0x2800", 2568 "ActionFlags": ["service_action", "report"], 2569 2570 "SRC": { 2571 "ReasonCode": "0x2809", 2572 "Words6To9": {} 2573 }, 2574 2575 "Callouts": [ 2576 { 2577 "CalloutList": [ 2578 { 2579 "Priority": "high", 2580 "SymbolicFRU": "ambient_temp" 2581 } 2582 ] 2583 } 2584 ], 2585 2586 "Documentation": { 2587 "Description": "The ambient temperature passed the EPOW4 limit.", 2588 "Message": "The ambient temperature passed the EPOW4 limit. The system will shut down", 2589 "Notes": [ 2590 "This error occurs when the ambient temperature surpassed", 2591 "the EPOW4 shutdown limit." 2592 ] 2593 } 2594 }, 2595 2596 { 2597 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHigh", 2598 "Subsystem": "ext_env", 2599 "ComponentID": "0x2800", 2600 "Severity": "predictive", 2601 "ActionFlags": ["service_action", "report"], 2602 2603 "SRC": { 2604 "ReasonCode": "0x280A", 2605 "Words6To9": {} 2606 }, 2607 2608 "CalloutsUsingAD": { 2609 "ADName": "SENSOR_NAME", 2610 "CalloutsWithTheirADValues": [ 2611 { 2612 "ADValue": "/xyz/openbmc_project/sensors/altitude/Altitude", 2613 "Callouts": [ 2614 { 2615 "CalloutList": [ 2616 { "Priority": "high", "SymbolicFRU": "altitude" } 2617 ] 2618 } 2619 ] 2620 } 2621 ] 2622 }, 2623 2624 "Documentation": { 2625 "Description": "An altitude sensor exceeded its warning threshold.", 2626 "Message": "An altitude sensor exceeded its warning threshold.", 2627 "Notes": [ 2628 "The virtual altitude sensor crossed its warning threshold value", 2629 " and a symbolic FRU will be added." 2630 ] 2631 } 2632 }, 2633 2634 { 2635 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.AltitudeWarningHighClear", 2636 "Subsystem": "ext_env", 2637 "ComponentID": "0x2800", 2638 "Severity": "non_error", 2639 "ActionFlags": ["report"], 2640 "EventType": "env_normal", 2641 2642 "SRC": { 2643 "ReasonCode": "0x280B", 2644 "Words6To9": {} 2645 }, 2646 2647 "Documentation": { 2648 "Description": "An altitude sensor is under its warning threshold.", 2649 "Message": "An altitude sensor is under its warning threshold.", 2650 "Notes": [ 2651 "The virtual altitude sensor is under its warning threshold value", 2652 " and a symbolic FRU will be added." 2653 ] 2654 } 2655 }, 2656 2657 { 2658 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLow", 2659 "Subsystem": "cec_tod", 2660 "ComponentID": "0x2800", 2661 "Severity": "predictive", 2662 "ActionFlags": ["service_action", "report"], 2663 2664 "SRC": { 2665 "ReasonCode": "0x280C", 2666 "Words6To9": {} 2667 }, 2668 2669 "CalloutsUsingAD": { 2670 "ADName": "SENSOR_NAME", 2671 "CalloutsWithTheirADValues": [ 2672 { 2673 "ADValue": "/xyz/openbmc_project/sensors/voltage/Battery_Voltage", 2674 "Callouts": [ 2675 { 2676 "System": "ibm,rainier", 2677 "CalloutList": [ 2678 { 2679 "Priority": "high", 2680 "LocCode": "P0-E0" 2681 } 2682 ] 2683 }, 2684 { 2685 "System": "ibm,everest", 2686 "CalloutList": [ 2687 { 2688 "Priority": "high", 2689 "LocCode": "P0-C0-E0" 2690 } 2691 ] 2692 } 2693 ] 2694 } 2695 ] 2696 }, 2697 2698 "Documentation": { 2699 "Description": "A voltage sensor went below its critical low threshold.", 2700 "Message": "A voltage sensor went below its critical low threshold." 2701 } 2702 }, 2703 2704 { 2705 "Name": "xyz.openbmc_project.Sensor.Threshold.Error.VoltageCriticalLowClear", 2706 "Subsystem": "cec_tod", 2707 "ComponentID": "0x2800", 2708 "Severity": "non_error", 2709 "ActionFlags": ["report"], 2710 2711 "SRC": { 2712 "ReasonCode": "0x280D", 2713 "Words6To9": {} 2714 }, 2715 2716 "Documentation": { 2717 "Description": "A voltage sensor is over its critical low threshold.", 2718 "Message": "A voltage sensor is over its critical low threshold." 2719 } 2720 }, 2721 2722 { 2723 "Name": "com.ibm.VPD.Error.InvalidEepromPath", 2724 "Subsystem": "cec_vpd", 2725 "ComponentID": "0x4000", 2726 2727 "SRC": { 2728 "ReasonCode": "0x4000", 2729 "Words6To9": 2730 { 2731 "6": 2732 { 2733 "Description": "Errno of the failure.", 2734 "AdditionalDataPropSource": "CALLOUT_ERRNO" 2735 } 2736 } 2737 }, 2738 2739 "Documentation": { 2740 "Description": "A path access error ocurred", 2741 "Message": "An EEPROM path access error occurred.", 2742 "Notes": [ 2743 "This error occurs when parser is unable to access", 2744 "EEPROM path. Errno and device path are captured as", 2745 "additional data." 2746 ] 2747 } 2748 }, 2749 2750 { 2751 "Name": "com.ibm.VPD.Error.InvalidVPD", 2752 "Subsystem": "cec_vpd", 2753 "ComponentID": "0x4000", 2754 2755 "SRC": { 2756 "ReasonCode": "0x4001", 2757 "Words6To9": 2758 { 2759 } 2760 }, 2761 2762 "Documentation": { 2763 "Description": "Invalid VPD data.", 2764 "Message": "A VPD data exception occurred.", 2765 "Notes": [ 2766 "This error occurs when VPD data is found to be", 2767 "invalid. This can be when VPD file is missing out", 2768 "mandatory records.Inventory path is captured in", 2769 "additional data." 2770 ] 2771 } 2772 }, 2773 2774 { 2775 "Name": "com.ibm.VPD.Error.EccCheckFailed", 2776 "Subsystem": "cec_vpd", 2777 "ComponentID": "0x4000", 2778 2779 "SRC": { 2780 "ReasonCode": "0x4002", 2781 "Words6To9": 2782 { 2783 } 2784 }, 2785 2786 "Documentation": { 2787 "Description": "Invalid VPD ecc data.", 2788 "Message": "A VPD ecc exception occurred.", 2789 "Notes": [ 2790 "This error occurs when VPD ecc check fails for the FRU.", 2791 "Inventory path for the failed FRU is captured in additonal", 2792 "data." 2793 ] 2794 } 2795 }, 2796 2797 { 2798 "Name": "com.ibm.VPD.Error.InvalidJson", 2799 "Subsystem": "cec_vpd", 2800 "ComponentID": "0x4000", 2801 2802 "SRC": { 2803 "ReasonCode": "0x4003", 2804 "Words6To9": 2805 { 2806 } 2807 }, 2808 2809 "Documentation": { 2810 "Description": "Invalid Json", 2811 "Message": "A Json failure occurred.", 2812 "Notes": [ 2813 "This error occurs when parser fails to access", 2814 "Json file or there is any issue with Json data.", 2815 "Failed Json path and cause of failure is captured", 2816 "in additional data." 2817 ] 2818 } 2819 }, 2820 2821 { 2822 "Name": "com.ibm.VPD.Error.BlankSystemVPD", 2823 "Subsystem": "cec_vpd", 2824 "ComponentID": "0x4000", 2825 2826 "SRC": { 2827 "ReasonCode": "0x4004", 2828 "Words6To9": 2829 { 2830 } 2831 }, 2832 2833 "Documentation": { 2834 "Description": "System VPD restore failed", 2835 "Message": "A system VPD restoration error occurred.", 2836 "Notes": [ 2837 "This error occurs when restoring of system VPD fails.", 2838 "The FRU path and reason for failure is captured in", 2839 "additional data." 2840 ] 2841 } 2842 }, 2843 2844 { 2845 "Name": "com.ibm.VPD.Error.DbusFailure", 2846 "Subsystem": "cec_vpd", 2847 "ComponentID": "0x4000", 2848 2849 "SRC": { 2850 "ReasonCode": "0x4005", 2851 "Words6To9": 2852 { 2853 } 2854 }, 2855 2856 "Documentation": { 2857 "Description": "Dbus exception", 2858 "Message": "A Dbus internal error occurred.", 2859 "Notes": [ 2860 "This error occurs when Dbus operation fails.", 2861 "Exceptions details are captured in additonal", 2862 "data." 2863 ] 2864 } 2865 }, 2866 2867 { 2868 "Name": "org.open_power.Host.Boot.Error.WatchdogTimeout", 2869 "Subsystem": "cec_sp_hostboot_iface", 2870 2871 "SRC": 2872 { 2873 "ReasonCode": "0xC101", 2874 "Words6To9": 2875 { 2876 } 2877 }, 2878 2879 "Documentation": 2880 { 2881 "Description": "Host did not respond within the watchdog timeout interval", 2882 "Message": "Host did not respond before the watchdog timeout interval expired", 2883 "Notes": [ 2884 "Host did not respond before the expiry of the watchdog timeout interval.", 2885 "Collecting hostboot dump." 2886 ] 2887 } 2888 } 2889 2890 ] 2891} 2892