1# Sensor Monitor 2 3This application can take action based on sensor thresholds and values. 4 5## Available Monitors 6 7### ShutdownAlarmMonitor 8 9This monitor will watch all instances of the 10`xyz.openbmc_project.Sensor.Threshold.HardShutdown` and 11`xyz.openbmc_project.Sensor.Threshold.SoftShutdown` D-Bus interfaces for the 12alarm properties to trip. When this happens, a configurable timer is started 13at the end of which a power off is executed if the alarms haven't reset by that 14time. Event logs will also be created. 15 16The configuration options `SHUTDOWN_ALARM_HARD_SHUTDOWN_DELAY_MS` and 17`SHUTDOWN_ALARM_SOFT_SHUTDOWN_DELAY_MS` can be used to change the delays. 18 19### ThresholdAlarmLogger 20 21This monitor will watch the alarm properties on the following threshold 22D-Bus interfaces: 23 24- `xyz.openbmc_project.Sensor.Threshold.Warning` 25- `xyz.openbmc_project.Sensor.Threshold.Critical` 26- `xyz.openbmc_project.Sensor.Threshold.PerformanceLoss` 27 28When the alarm properties are asserted, event logs are created. When they are 29deasserted, informational event logs are created. 30