1description: > 2 Implement to provide critical class sensor thresholds. Objects implementing 3 Sensor.Threshold.Critical must be instantiated in the correct hierarchy within 4 the sensors namespace. The following sensor hierarchies are recognized: 5 temperature 6 fan_tach 7 voltage 8 altitude 9 current 10 power 11 energy 12 13 Additionally, any object implementing Sensor.Threshold.Critical must also 14 implement Sensor.Value. 15 16properties: 17 - name: CriticalHigh 18 type: double 19 default: NaN 20 description: > 21 The upper bound of the critical threshold. A value of 'NaN' is used 22 to indicate there is no threshold of this type. 23 - name: CriticalLow 24 type: double 25 default: NaN 26 description: > 27 The lower bound of the critical threshold. A value of 'NaN' is used 28 to indicate there is no threshold of this type. 29 - name: CriticalAlarmHigh 30 type: boolean 31 description: > 32 True if the sensor value has exceeded the defined bound. 33 False if the sensor value has not exceeded the defined bound. 34 35 CriticalAlarmHigh may be set to False to clear an alarm condition. 36 The behavior of setting CriticalAlarmHigh to True is undefined. 37 - name: CriticalAlarmLow 38 type: boolean 39 description: > 40 True if the sensor value has exceeded the defined bound. 41 False if the sensor value has not exceeded the defined bound. 42 43 CriticalAlarmLow may be set to False to clear an alarm condition. 44 The behavior of setting CriticalAlarmLow to True is undefined. 45signals: 46 - name: CriticalHighAlarmAsserted 47 description: > 48 The high threshold alarm asserted. 49 properties: 50 - name: SensorValue 51 type: double 52 description: > 53 The sensor value that triggered the alarm change. 54 - name: CriticalHighAlarmDeasserted 55 description: > 56 The high threshold alarm deasserted. 57 properties: 58 - name: SensorValue 59 type: double 60 description: > 61 The sensor value that triggered the alarm change. 62 - name: CriticalLowAlarmAsserted 63 description: > 64 The low threshold alarm asserted. 65 properties: 66 - name: SensorValue 67 type: double 68 description: > 69 The sensor value that triggered the alarm change. 70 - name: CriticalLowAlarmDeasserted 71 description: > 72 The low threshold alarm deasserted. 73 properties: 74 - name: SensorValue 75 type: double 76 description: > 77 The sensor value that triggered the alarm change. 78