1description: > 2 Implement to provide alternative thermal control modes of a system that can 3 be enabled, overriding the system defaults. 4 5 Control.ThermalMode.Supported is read only. 6 Implementation of this interface populates the list of supported modes. 7 Control.ThermalMode.Current is read/write. 8 Implementation specific mode for the thermal control application 9 to run in. 10 11properties: 12 - name: Supported 13 type: array[string] 14 flags: 15 - readonly 16 description: > 17 An implementation specific list of supported modes that the thermal 18 control application can be configured to provide for a platform. 19 - name: Current 20 type: string 21 default: "Default" 22 description: > 23 The current mode the thermal control application should execute in 24 selected from the supported modes provided. 25