1description: > 2 "org.freedesktop.UPower.Device -- Device interface 3 Defined at https://upower.freedesktop.org/docs/Device.html 4 Objects implementing org.freedesktop.UPower.Device also implement the 5 org.freedesktop.DBus.Introspectable and org.freedesktop.DBus.Properties 6 interfaces. Unless otherwise noted, an empty string or the value 0 in a 7 property on this interface means not set." 8 9methods: 10 - name: Refresh 11 description: > 12 "Refreshes the data collected from the power source. Callers need the 13 org.freedesktop.upower.refresh-power-source authorization" 14 15 - name: GetHistory 16 description: > 17 "Gets history for the power device that is persistent across 18 reboots." 19 parameters: 20 - name: type 21 type: string 22 description: > 23 "The type of history. Valid types are rate or charge." 24 - name: timespan 25 type: uint32 26 description: > 27 "The amount of data to return in seconds, or 0 for all." 28 - name: resolution 29 type: uint32 30 description: > 31 "The approximate number of points to return. A higher resolution 32 is 33 more accurate, at the expense of plotting speed." 34 returns: 35 - name: data 36 type: array[struct[uint32, double, uint32]] 37 description: > 38 "The history data for the power device, if the device supports 39 history. Data is ordered from the earliest in time, to the 40 newest 41 data point. Each element contains the following members: 42 time: The time value in seconds from the gettimeofday() 43 method. 44 value: The data value, for instance the rate in W or the 45 charge 46 in %. 47 state: The state of the device, for instance charging or 48 discharging." 49 50 - name: GetStatistics 51 description: > 52 "Gets statistics for the power device that may be interesting to show 53 on a graph in the session." 54 parameters: 55 - name: type 56 type: string 57 description: > 58 "The mode for the statistics. Valid types are charging or 59 discharging." 60 returns: 61 - name: data 62 type: array[struct[double, double]] 63 description: > 64 "The statistics data for the power device. Each element contains 65 the 66 following members: 67 value: The value of the percentage point, usually in seconds. 68 accuracy: The accuracy of the prediction in percent." 69 70properties: 71 - name: NativePath 72 default: "" 73 type: string 74 description: > 75 "OS specific native path of the power source. On Linux this is the 76 sysfs path, for example 77 /sys/devices/LNXSYSTM:00/device:00/PNP0C0A:00/power_supply/BAT0. Is 78 blank if the device is being driven by a user space driver." 79 - name: Vendor 80 default: "" 81 type: string 82 description: > 83 "Name of the vendor of the battery." 84 - name: Model 85 default: "" 86 type: string 87 description: > 88 "Name of the model of this battery." 89 - name: Serial 90 default: "" 91 type: string 92 description: > 93 "Unique serial number of the battery." 94 - name: UpdateTime 95 default: 0 96 type: uint64 97 description: > 98 "The point in time (seconds since the Epoch Jan 1, 1970 0:00 UTC) 99 that data was read from the power source." 100 - name: Type 101 default: 0 102 type: uint32 103 description: > 104 "Type of power source. 105 0: Unknown 106 1: Line Power 107 2: Battery 108 3: Ups 109 4: Monitor 110 5: Mouse 111 6: Keyboard 112 7: Pda 113 8: Phone" 114 - name: PowerSupply 115 default: false 116 type: boolean 117 description: > 118 "If the power device is used to supply the system. This would be set 119 TRUE for laptop batteries and UPS devices, but set FALSE for wireless 120 mice or PDAs." 121 - name: HasHistory 122 default: false 123 type: boolean 124 description: > 125 "If the power device has history." 126 - name: HasStatistics 127 default: false 128 type: boolean 129 description: > 130 "If the power device has statistics." 131 - name: Online 132 default: false 133 type: boolean 134 description: > 135 "Whether power is currently being provided through line power. This 136 property is only valid if the property type has the value 137 'line-power'." 138 - name: Energy 139 default: 0.0 140 type: double 141 description: > 142 "Amount of energy (measured in Wh) currently available in the power 143 source. This property is only valid if the property type has the 144 value 'battery'." 145 - name: EnergyEmpty 146 default: 0.0 147 type: double 148 description: > 149 "Amount of energy (measured in Wh) in the power source when it's 150 considered to be empty. This property is only valid if the property 151 type has the value 'battery'." 152 - name: EnergyFull 153 default: 0.0 154 type: double 155 description: > 156 "Amount of energy (measured in Wh) in the power source when it's 157 considered full. This property is only valid if the property type 158 has the value 'battery'." 159 - name: EnergyFullDesign 160 default: 0.0 161 type: double 162 description: > 163 "Amount of energy (measured in Wh) the power source is designed to 164 hold when it's considered full. This property is only valid if the 165 property type has the value 'battery'." 166 - name: EnergyRate 167 default: 0.0 168 type: double 169 description: > 170 "Amount of energy being drained from the source, measured in W. If 171 positive, the source is being discharged, if negative it's being 172 charged. This property is only valid if the property type has the 173 value 'battery'." 174 - name: Voltage 175 default: 0.0 176 type: double 177 description: > 178 "Voltage in the Cell or being recorded by the meter." 179 - name: Luminosity 180 default: 0.0 181 type: double 182 description: > 183 "Luminosity being recorded by the meter." 184 - name: TimeToEmpty 185 default: 0 186 type: int64 187 description: > 188 "Number of seconds until the power source is considered empty. Is set 189 to 0 if unknown. This property is only valid if the property type 190 has the value 'battery'." 191 - name: TimeToFull 192 default: 0 193 type: int64 194 description: > 195 "Number of seconds until the power source is considered full. Is set 196 to 0 if unknown. This property is only valid if the property type 197 has the value 'battery'." 198 - name: Percentage 199 default: 0.0 200 type: double 201 description: > 202 "The amount of energy left in the power source expressed as a 203 percentage between 0 and 100. Typically this is the same as (energy - 204 energy-empty) / (energy-full - energy-empty). However, some primitive 205 power sources are capable of only reporting percentages and in this 206 case the energy-* properties will be unset while this property is 207 set. This property is only valid if the property type has the value 208 'battery'." 209 - name: Temperature 210 default: 0.0 211 type: double 212 description: > 213 "The temperature of the device in degrees Celsius. This property is 214 only valid if the property type has the value 'battery'." 215 - name: IsPresent 216 default: false 217 type: boolean 218 description: > 219 "If the power source is present in the bay. This field is required as 220 some batteries are hot-removable, for example expensive UPS and most 221 laptop batteries. This property is only valid if the property type 222 has the value 'battery'." 223 - name: State 224 default: 0 225 type: uint32 226 description: > 227 "The battery power state. 228 0: Unknown 229 1: Charging 230 2: Discharging 231 3: Empty 232 4: Fully charged 233 5: Pending charge 234 6: Pending discharge 235 This property is only valid if the property type has the value 236 'battery'." 237 - name: IsRechargeable 238 default: false 239 type: boolean 240 description: > 241 "If the power source is rechargeable. This property is only valid if 242 the property type has the value 'battery'." 243 - name: Capacity 244 default: 0.0 245 type: double 246 description: > 247 "The capacity of the power source expressed as a percentage between 0 248 and 100. The capacity of the battery will reduce with age. A capacity 249 value less than 75% is usually a sign that you should renew your 250 battery. Typically this value is the same as (full-design / full) * 251 100. However, some primitive power sources are not capable reporting 252 capacity and in this case the capacity property will be unset. This 253 property is only valid if the property type has the value 'battery'." 254 - name: Technology 255 default: 0 256 type: uint32 257 description: > 258 "Technology used in the battery: 259 0: Unknown 260 1: Lithium ion 261 2: Lithium polymer 262 3: Lithium iron phosphate 263 4: Lead acid 264 5: Nickel cadmium 265 6: Nickel metal hydride 266 This property is only valid if the property type has the value 267 'battery'." 268 - name: WarningLevel 269 default: 0 270 type: uint32 271 description: > 272 "Warning level of the battery: 273 0: Unknown 274 1: None 275 2: Discharging (only for UPSes) 276 3: Low 277 4: Critical 278 5: Action" 279 - name: BatteryLevel 280 default: 0 281 type: uint32 282 description: > 283 "Level of the battery: 284 0: Unknown 285 1: None (the battery does not use a coarse level of battery 286 reporting) 287 3: Low 288 4: Critical 289 6: Normal 290 7: High 291 8: Full" 292 - name: IconName 293 default: "" 294 type: string 295 description: > 296 "An icon name, following the Icon Naming Specification" 297