1description: > 2 "org.freedesktop.UPower.Device -- Device interface 3 Defined at https://upower.freedesktop.org/docs/Device.html 4 Objects implementing org.freedesktop.UPower.Device also implement the 5 org.freedesktop.DBus.Introspectable and org.freedesktop.DBus.Properties 6 interfaces. Unless otherwise noted, an empty string or the value 0 in a 7 property on this interface means not set." 8 9methods: 10 - name: Refresh 11 description: > 12 "Refreshes the data collected from the power source. Callers need the 13 org.freedesktop.upower.refresh-power-source authorization" 14 15 - name: GetHistory 16 description: > 17 "Gets history for the power device that is persistent across 18 reboots." 19 parameters: 20 - name: type 21 type: string 22 description: > 23 "The type of history. Valid types are rate or charge." 24 - name: timespan 25 type: uint32 26 description: > 27 "The amount of data to return in seconds, or 0 for all." 28 - name: resolution 29 type: uint32 30 description: > 31 "The approximate number of points to return. A higher resolution is 32 more accurate, at the expense of plotting speed." 33 returns: 34 - name: data 35 type: array[struct[uint32, double, uint32]] 36 description: > 37 "The history data for the power device, if the device supports 38 history. Data is ordered from the earliest in time, to the newest 39 data point. Each element contains the following members: 40 time: The time value in seconds from the gettimeofday() method. 41 value: The data value, for instance the rate in W or the charge 42 in %. 43 state: The state of the device, for instance charging or 44 discharging." 45 46 - name: GetStatistics 47 description: > 48 "Gets statistics for the power device that may be interesting to show 49 on a graph in the session." 50 parameters: 51 - name: type 52 type: string 53 description: > 54 "The mode for the statistics. Valid types are charging or 55 discharging." 56 returns: 57 - name: data 58 type: array[struct[double, double]] 59 description: > 60 "The statistics data for the power device. Each element contains the 61 following members: 62 value: The value of the percentage point, usually in seconds. 63 accuracy: The accuracy of the prediction in percent." 64 65properties: 66 - name: NativePath 67 default: "" 68 type: string 69 description: > 70 "OS specific native path of the power source. On Linux this is the 71 sysfs path, for example 72 /sys/devices/LNXSYSTM:00/device:00/PNP0C0A:00/power_supply/BAT0. Is 73 blank if the device is being driven by a user space driver." 74 - name: Vendor 75 default: "" 76 type: string 77 description: > 78 "Name of the vendor of the battery." 79 - name: Model 80 default: "" 81 type: string 82 description: > 83 "Name of the model of this battery." 84 - name: Serial 85 default: "" 86 type: string 87 description: > 88 "Unique serial number of the battery." 89 - name: UpdateTime 90 default: 0 91 type: uint64 92 description: > 93 "The point in time (seconds since the Epoch Jan 1, 1970 0:00 UTC) 94 that data was read from the power source." 95 - name: Type 96 default: 0 97 type: uint32 98 description: > 99 "Type of power source. 100 0: Unknown 101 1: Line Power 102 2: Battery 103 3: Ups 104 4: Monitor 105 5: Mouse 106 6: Keyboard 107 7: Pda 108 8: Phone" 109 - name: PowerSupply 110 default: false 111 type: boolean 112 description: > 113 "If the power device is used to supply the system. This would be set 114 TRUE for laptop batteries and UPS devices, but set FALSE for wireless 115 mice or PDAs." 116 - name: HasHistory 117 default: false 118 type: boolean 119 description: > 120 "If the power device has history." 121 - name: HasStatistics 122 default: false 123 type: boolean 124 description: > 125 "If the power device has statistics." 126 - name: Online 127 default: false 128 type: boolean 129 description: > 130 "Whether power is currently being provided through line power. This 131 property is only valid if the property type has the value 132 'line-power'." 133 - name: Energy 134 default: 0.0 135 type: double 136 description: > 137 "Amount of energy (measured in Wh) currently available in the power 138 source. This property is only valid if the property type has the 139 value 'battery'." 140 - name: EnergyEmpty 141 default: 0.0 142 type: double 143 description: > 144 "Amount of energy (measured in Wh) in the power source when it's 145 considered to be empty. This property is only valid if the property 146 type has the value 'battery'." 147 - name: EnergyFull 148 default: 0.0 149 type: double 150 description: > 151 "Amount of energy (measured in Wh) in the power source when it's 152 considered full. This property is only valid if the property type 153 has the value 'battery'." 154 - name: EnergyFullDesign 155 default: 0.0 156 type: double 157 description: > 158 "Amount of energy (measured in Wh) the power source is designed to 159 hold when it's considered full. This property is only valid if the 160 property type has the value 'battery'." 161 - name: EnergyRate 162 default: 0.0 163 type: double 164 description: > 165 "Amount of energy being drained from the source, measured in W. If 166 positive, the source is being discharged, if negative it's being 167 charged. This property is only valid if the property type has the 168 value 'battery'." 169 - name: Voltage 170 default: 0.0 171 type: double 172 description: > 173 "Voltage in the Cell or being recorded by the meter." 174 - name: Luminosity 175 default: 0.0 176 type: double 177 description: > 178 "Luminosity being recorded by the meter." 179 - name: TimeToEmpty 180 default: 0 181 type: int64 182 description: > 183 "Number of seconds until the power source is considered empty. Is set 184 to 0 if unknown. This property is only valid if the property type 185 has the value 'battery'." 186 - name: TimeToFull 187 default: 0 188 type: int64 189 description: > 190 "Number of seconds until the power source is considered full. Is set 191 to 0 if unknown. This property is only valid if the property type 192 has the value 'battery'." 193 - name: Percentage 194 default: 0.0 195 type: double 196 description: > 197 "The amount of energy left in the power source expressed as a 198 percentage between 0 and 100. Typically this is the same as (energy - 199 energy-empty) / (energy-full - energy-empty). However, some primitive 200 power sources are capable of only reporting percentages and in this 201 case the energy-* properties will be unset while this property is 202 set. This property is only valid if the property type has the value 203 'battery'." 204 - name: Temperature 205 default: 0.0 206 type: double 207 description: > 208 "The temperature of the device in degrees Celsius. This property is 209 only valid if the property type has the value 'battery'." 210 - name: IsPresent 211 default: false 212 type: boolean 213 description: > 214 "If the power source is present in the bay. This field is required as 215 some batteries are hot-removable, for example expensive UPS and most 216 laptop batteries. This property is only valid if the property type 217 has the value 'battery'." 218 - name: State 219 default: 0 220 type: uint32 221 description: > 222 "The battery power state. 223 0: Unknown 224 1: Charging 225 2: Discharging 226 3: Empty 227 4: Fully charged 228 5: Pending charge 229 6: Pending discharge 230 This property is only valid if the property type has the value 231 'battery'." 232 - name: IsRechargeable 233 default: false 234 type: boolean 235 description: > 236 "If the power source is rechargeable. This property is only valid if 237 the property type has the value 'battery'." 238 - name: Capacity 239 default: 0.0 240 type: double 241 description: > 242 "The capacity of the power source expressed as a percentage between 0 243 and 100. The capacity of the battery will reduce with age. A capacity 244 value less than 75% is usually a sign that you should renew your 245 battery. Typically this value is the same as (full-design / full) * 246 100. However, some primitive power sources are not capable reporting 247 capacity and in this case the capacity property will be unset. This 248 property is only valid if the property type has the value 'battery'." 249 - name: Technology 250 default: 0 251 type: uint32 252 description: > 253 "Technology used in the battery: 254 0: Unknown 255 1: Lithium ion 256 2: Lithium polymer 257 3: Lithium iron phosphate 258 4: Lead acid 259 5: Nickel cadmium 260 6: Nickel metal hydride 261 This property is only valid if the property type has the value 262 'battery'." 263 - name: WarningLevel 264 default: 0 265 type: uint32 266 description: > 267 "Warning level of the battery: 268 0: Unknown 269 1: None 270 2: Discharging (only for UPSes) 271 3: Low 272 4: Critical 273 5: Action" 274 - name: BatteryLevel 275 default: 0 276 type: uint32 277 description: > 278 "Level of the battery: 279 0: Unknown 280 1: None (the battery does not use a coarse level of battery reporting) 281 3: Low 282 4: Critical 283 6: Normal 284 7: High 285 8: Full" 286 - name: IconName 287 default: "" 288 type: string 289 description: > 290 "An icon name, following the Icon Naming Specification" 291