1*** Settings ***
2Documentation       Get the system power supply voltage readings.
3
4Resource            ../../lib/bmc_redfish_resource.robot
5Resource            ../../lib/bmc_redfish_utils.robot
6Resource            ../../lib/openbmc_ffdc.robot
7Library             ../../lib/gen_robot_valid.py
8
9Suite Setup         Suite Setup Execution
10Suite Teardown      Suite Teardown Execution
11Test Setup          Printn
12Test Teardown       Test Teardown Execution
13
14
15*** Test Cases ***
16
17Verify Power Supplies Input Watts
18    [Documentation]  Verify there are no invalid power supply input watt records.
19    [Tags]  Verify_Power_Supplies_Input_Watts
20    [Template]  Verify Watts Record
21
22    # record_type   redfish_uri                       reading_type
23    PowerSupplies   ${REDFISH_CHASSIS_POWER_URI}      PowerInputWatts
24
25
26Verify Power Supplies Input Output Voltages
27    [Documentation]  Verify there are no invalid power supply voltage records.
28    [Tags]  Verify_Power_Supplies_Input_Output_Voltages
29    [Template]  Verify Voltage Records
30
31    # record_type   redfish_uri                        reading_type
32    Voltages        ${REDFISH_CHASSIS_POWER_URI}       ReadingVolts
33
34
35*** Keywords ***
36
37Verify Watts Record
38    [Documentation]  Verify the power watt records.
39    [Arguments]  ${record_type}  ${redfish_uri}  ${reading_type}
40
41    # Description of Arguments(s):
42    # record_type    The sensor record type (e.g. "PowerSupplies")
43    # redfish_uri    The power supply URI (e.g. /redfish/v1/Chassis/chassis/Power)
44    # reading_type   The power watt readings (e.g. "PowerInputWatts")
45
46    Verify Valid Records  ${record_type}  ${redfish_uri}  ${reading_type}
47
48
49Verify Voltage Records
50    [Documentation]  Verify the power voltage records.
51    [Arguments]  ${record_type}  ${redfish_uri}  ${reading_type}
52
53    # Description of Arguments(s):
54    # record_type    The sensor record type (e.g. "Voltages")
55    # redfish_uri    The power supply URI (e.g. /redfish/v1/Chassis/chassis/Power)
56    # reading_type   The power voltage readings (e.g. "ReadingVolts")
57
58    Verify Valid Records  ${record_type}  ${redfish_uri}  ${reading_type}
59
60    ${records}=  Redfish.Get Attribute  ${redfish_uri}  ${record_type}
61
62    ${invalid_records}=  Evaluate
63    ...  [x for x in ${records} if not x['LowerThresholdNonCritical'] <= x['${reading_type}'] <= x['UpperThresholdNonCritical']]
64
65    Valid Length  invalid_records  max_length=0
66
67Suite Teardown Execution
68    [Documentation]  Do the post suite teardown.
69
70    Redfish.Logout
71
72
73Suite Setup Execution
74    [Documentation]  Do test case setup tasks.
75
76    Printn
77    Redfish Power On  stack_mode=skip
78    Redfish.Login
79
80
81Test Teardown Execution
82    [Documentation]  Do the post test teardown.
83
84    FFDC On Test Case Fail
85