1*** Settings *** 2 3Documentation Test Suite for Supported Fan Modules. 4 5Resource ../../lib/rest_client.robot 6Resource ../../lib/bmc_redfish_resource.robot 7Resource ../../lib/bmc_redfish_utils.robot 8Resource ../../lib/openbmc_ffdc.robot 9Resource ../../lib/resource.robot 10Resource ../../lib/boot_utils.robot 11Library ../../lib/gen_robot_valid.py 12Library ../../lib/gen_robot_keyword.py 13 14Suite Setup Suite Setup Execution 15Suite Teardown Suite Teardown Execution 16Test Setup Printn 17Test Teardown Test Teardown Execution 18 19 20*** Variables *** 21 22@{VALID_MODE_VALUES} DEFAULT CUSTOM HEAVY_IO MAX_BASE_FAN_FLOOR 23 24 25*** Test Cases *** 26 27Verify Current Fan Thermal Mode 28 [Documentation] Check current thermal fan mode is a valid mode value. 29 [Tags] Verify_Current_Fan_Thermal_Mode 30 31 # Example: 32 # /xyz/openbmc_project/control/thermal/0 33 # 34 # Response code:200, Content: { 35 # "data": { 36 # "Current": "DEFAULT", 37 # "Supported": [ 38 # "DEFAULT", 39 # "CUSTOM", 40 # "HEAVY_IO", 41 # "MAX_BASE_FAN_FLOOR" 42 # }, 43 # }, 44 # "message": "200 OK", 45 # "status": "ok" 46 # } 47 48 ${current}= Read Attribute ${THERMAL_CONTROL_URI} Current 49 Rprint Vars current 50 51 Valid Value current valid_values=${VALID_MODE_VALUES} 52 53 54Verify Supported Fan Thermal Modes Available 55 [Documentation] Check supported fan thermal modes are valid mode values. 56 [Tags] Verify_Supported_Fan_Thermal_Modes_Available 57 58 ${supported}= Read Attribute ${THERMAL_CONTROL_URI} Supported 59 Rprint Vars supported 60 61 Valid List supported valid_values=${VALID_MODE_VALUES} 62 63 64Verify Supported Fan Thermal Modes Switch At Standby 65 [Documentation] Check that supported modes are set successfully at standby. 66 [Tags] Verify_Supported_Fan_Thermal_Modes_Switch_At_Standby 67 [Template] Set and Verify Thermal Mode Switches 68 69 # pre_req_state thermal_mode_type 70 Off DEFAULT 71 Off CUSTOM 72 Off HEAVY_IO 73 Off MAX_BASE_FAN_FLOOR 74 75 76Verify Supported Fan Thermal Modes Switch At Runtime 77 [Documentation] Check that supported modes are set successfully at runtime. 78 [Tags] Verify_Supported_Fan_Thermal_Modes_Switch_At_Runtime 79 [Template] Set and Verify Thermal Mode Switches 80 81 # pre_req_state thermal_mode 82 On DEFAULT 83 On CUSTOM 84 On HEAVY_IO 85 On MAX_BASE_FAN_FLOOR 86 87 88Verify Supported Fan Thermal Mode Remains Set After Boot 89 [Documentation] Check that supported modes remain set at runtime. 90 [Tags] Verify_Supported_Fan_Thermal_Mode_Remains_Set_After_Boot 91 [Template] Set and Verify Thermal Mode After Boot 92 93 # pre_req_state thermal_mode_type 94 Off DEFAULT 95 Off CUSTOM 96 Off HEAVY_IO 97 Off MAX_BASE_FAN_FLOOR 98 99 100*** Keywords *** 101 102Set and Verify Thermal Mode Switches 103 [Documentation] Verify the thermal mode switches successfully at standby or runtime. 104 [Arguments] ${pre_req_state} ${thermal_mode} 105 106 # Description of Arguments(s): 107 # thermal_mode Read the supported thermal mode (e.g. "CUSTOM") 108 # pre_req_state Set the state of the host to Standby or Runtime (e.g. "Running") 109 110 Run Key U Redfish Power ${pre_req_state} \ stack_mode=skip \ quiet=1 111 Redfish.Login 112 113 ${mode}= Redfish.Put ${THERMAL_CONTROL_URI}/attr/Current body={"data": "${thermal_mode}"} 114 115 ${current}= Read Attribute ${THERMAL_CONTROL_URI} Current 116 Should Be Equal As Strings ${thermal_mode} ${current} 117 ... msg=The thermal mode does not match the current fan mode. 118 Rprint Vars current 119 120 121Set and Verify Thermal Mode After Boot 122 [Documentation] Verify the thermal mode remains set at runtime. 123 [Arguments] ${pre_req_state} ${thermal_mode} 124 125 Set and Verify Thermal Mode Switches ${pre_req_state} ${thermal_mode} 126 127 Run Key U Redfish Power On \ stack_mode=normal \ quiet=1 128 Redfish.Login 129 130 ${current}= Read Attribute ${THERMAL_CONTROL_URI} Current 131 Should Be Equal As Strings ${thermal_mode} ${current} 132 ... msg=The current thermal fan mode switched successfully. 133 Rprint Vars current 134 135 136Suite Teardown Execution 137 [Documentation] Do the post suite teardown. 138 139 Redfish.Logout 140 141 142Suite Setup Execution 143 [Documentation] Do test case setup tasks. 144 145 Printn 146 Redfish.Login 147 148 149Test Teardown Execution 150 [Documentation] Do the post test teardown. 151 152 FFDC On Test Case Fail 153