1*** Settings *** 2Documentation Update the BMC code on a target BMC via Redifsh. 3 4# Test Parameters: 5# IMAGE_FILE_PATH The path to the BMC image file. 6# 7# Firmware update states: 8# Enabled Image is installed and either functional or active. 9# Disabled Image installation failed or ready for activation. 10# Updating Image installation currently in progress. 11 12Resource ../../lib/resource.robot 13Resource ../../lib/bmc_redfish_resource.robot 14Resource ../../lib/openbmc_ffdc.robot 15Resource ../../lib/common_utils.robot 16Resource ../../lib/code_update_utils.robot 17Resource ../../lib/redfish_code_update_utils.robot 18Resource ../../lib/utils.robot 19Library ../../lib/gen_robot_valid.py 20Library ../../lib/var_funcs.py 21Library ../../lib/gen_robot_keyword.py 22Library ../../lib/code_update_utils.py 23 24Suite Setup Suite Setup Execution 25Suite Teardown Redfish.Logout 26Test Setup Printn 27Test Teardown FFDC On Test Case Fail 28 29# Force the test to timedout to prevent test hanging. 30Test Timeout 30 minutes 31 32Force Tags BMC_Code_Update 33 34*** Variables *** 35 36${FORCE_UPDATE} ${0} 37${LOOP_COUNT} 20 38 39*** Test Cases *** 40 41Redfish BMC Code Update 42 [Documentation] Update the firmware image. 43 [Tags] Redfish_BMC_Code_Update 44 45 # Python module: get_version_tar(tar_file_path) 46 ${image_version}= code_update_utils.Get Version Tar ${IMAGE_FILE_PATH} 47 Rprint Vars image_version 48 49 # Python module: get_bmc_release_info() 50 ${bmc_release_info}= utils.Get BMC Release Info 51 ${functional_version}= Set Variable ${bmc_release_info['version_id']} 52 Rprint Vars functional_version 53 54 ${post_code_update_actions}= Get Post Boot Action 55 ${state}= Get Pre Reboot State 56 Rprint Vars state 57 58 # Check if the existing firmware is functional. 59 Pass Execution If '${functional_version}' == '${image_version}' 60 ... The existing ${image_version} firmware is already functional. 61 62 ${sw_inv}= Get Functional Firmware BMC image 63 ${nonfunctional_sw_inv}= Get Non Functional Firmware ${sw_inv} False 64 65 # Redfish active software image API. 66 Run Keyword If ${num_records} > 0 67 ... Run Keyword If '${nonfunctional_sw_inv['version']}' == '${image_version}' 68 ... Set Backup Firmware To Functional ${image_version} ${state} 69 70 Print Timen Performing firmware update ${image_version}. 71 72 Redfish Update Firmware 73 74 75Redfish Firmware Update Loop 76 [Documentation] Update the firmware image in loop. 77 [Tags] Redfish_Firmware_Update_Loop 78 [Template] Redfish Firmware Update In Loop 79 80 ${LOOP_COUNT} 81 82 83*** Keywords *** 84 85Suite Setup Execution 86 [Documentation] Do the suite setup. 87 88 Redfish.Login 89 # Delete BMC dump and Error logs. 90 Run Keyword And Ignore Error Redfish Delete All BMC Dumps 91 Run Keyword And Ignore Error Redfish Purge Event Log 92 # Checking for file existence. 93 Valid File Path IMAGE_FILE_PATH 94 95 Redfish Power Off stack_mode=skip 96 97 98Redfish Firmware Update In Loop 99 [Documentation] Update the firmware in loop. 100 [Arguments] ${update_loop_count} 101 102 # Description of argument(s): 103 # update_loop_count This value is used to run the firmware update in loop. 104 105 ${before_image_state}= Get BMC Functional Firmware 106 ${temp_update_loop_count}= Evaluate ${update_loop_count} + 1 107 108 FOR ${count} IN RANGE 1 ${temp_update_loop_count} 109 Print Timen ************************************** 110 Print Timen * The Current Loop Count is ${count} of ${update_loop_count} * 111 Print Timen ************************************** 112 Redfish Update Firmware 113 ${sw_inv}= Get Functional Firmware BMC update 114 ${nonfunctional_sw_inv}= Get Non Functional Firmware ${sw_inv} False 115 Run Keyword If ${nonfunctional_sw_inv['functional']} == False 116 ... Set BMC Image Priority To Least ${nonfunctional_sw_inv['version']} ${nonfunctional_sw_inv} 117 Redfish.Login 118 ${sw_inv}= Get Functional Firmware BMC update 119 ${nonfunctional_sw_inv}= Get Non Functional Firmware ${sw_inv} False 120 Delete BMC Image 121 END 122 123 ${after_image_state}= Get BMC Functional Firmware 124 Valid Value before_image_state["version"] ['${after_image_state["version"]}'] 125 126 127Delete BMC Image 128 [Documentation] Delete a BMC image from the BMC flash chip. 129 130 ${software_object}= Get Non Running BMC Software Object 131 Delete Image And Verify ${software_object} ${VERSION_PURPOSE_BMC} 132 133 134Activate Existing Firmware 135 [Documentation] Set firmware image to lower priority. 136 [Arguments] ${image_version} 137 138 # Description of argument(s): 139 # image_version Version of image. 140 141 ${software_inventory_record}= Get Software Inventory State By Version 142 ... ${image_version} 143 ${num_keys}= Get Length ${software_inventory_record} 144 145 Rprint Vars software_inventory_record 146 147 # If no software inventory record was found, there is no existing 148 # firmware for the given version and therefore no action to be taken. 149 Return From Keyword If not ${num_keys} 150 151 # Check if the existing firmware is functional. 152 Pass Execution If ${software_inventory_record['functional']} 153 ... The existing ${image_version} firmware is already functional. 154 155 # If existing firmware is not functional, then set the priority to least. 156 Print Timen The existing ${image_version} firmware is not yet functional. 157 Set BMC Image Priority To Least ${image_version} ${software_inventory_record} 158 159 Pass Execution The existing ${image_version} firmware is now functional. 160 161 162Get Image Priority 163 [Documentation] Get Current Image Priority. 164 [Arguments] ${image_version} 165 166 # Description of argument(s): 167 # image_version The Firmware image version (e.g. 2.8.0-dev-1107-g512028d95). 168 169 ${software_info}= Read Properties 170 ... ${SOFTWARE_VERSION_URI}/enumerate quiet=1 171 # Get only the record associated with our image_version. 172 173 ${software_info}= Filter Struct 174 ... ${software_info} [('Version', '${image_version}')] 175 # Convert from dict to list. 176 ${software_info}= Get Dictionary Values ${software_info} 177 178 [Return] ${software_info[0]['Priority']} 179 180 181Set BMC Image Priority To Least 182 [Documentation] Set BMC image priority to least value. 183 [Arguments] ${image_version} ${software_inventory} 184 185 # Description of argument(s): 186 # image_version The Firmware image version (e.g. 2.8.0-dev-1107-g512028d95). 187 # software_inventory Software inventory details. 188 189 ${least_priority}= Get Least Value Priority Image ${VERSION_PURPOSE_BMC} 190 ${cur_priority}= Get Image Priority ${image_version} 191 Rprint Vars least_priority cur_priority 192 193 Return From Keyword If '${least_priority}' == ${cur_priority} 194 Set Host Software Property 195 ... ${SOFTWARE_VERSION_URI}${software_inventory['image_id']} 196 ... Priority ${least_priority} 197 198 Redfish OBMC Reboot (off) 199 200 201Set Backup Firmware To Functional 202 [Documentation] Set the backup firmware to functional. 203 [Arguments] ${image_version} ${state} 204 205 # Description of argument(s): 206 # image_version Version of image. 207 # state Pre reboot state. 208 209 Print Timen Switch to back up and rebooting. 210 Switch Backup Firmware Image To Functional 211 Wait For Reboot start_boot_seconds=${state['epoch_seconds']} 212 Redfish Verify BMC Version ${IMAGE_FILE_PATH} 213 Pass Execution The backup firmware image ${image_version} is now functional. 214 215 216Redfish Update Firmware 217 [Documentation] Update the BMC firmware via redfish interface. 218 219 ${post_code_update_actions}= Get Post Boot Action 220 ${state}= Get Pre Reboot State 221 Rprint Vars state 222 Run Keyword And Ignore Error Set ApplyTime policy=OnReset 223 Redfish Upload Image And Check Progress State 224 ${tar_version}= Get Version Tar ${IMAGE_FILE_PATH} 225 ${image_info}= Get Software Inventory State By Version ${tar_version} 226 Run Key ${post_code_update_actions['${image_info["image_type"]}']['OnReset']} 227 Redfish.Login 228 Redfish Verify BMC Version ${IMAGE_FILE_PATH} 229 230