1*** Settings *** 2Documentation This suite tests Platform Event Log (PEL) functionality of OpenBMC. 3 4Library ../../lib/pel_utils.py 5Variables ../../data/pel_variables.py 6Resource ../../lib/list_utils.robot 7Resource ../../lib/logging_utils.robot 8Resource ../../lib/openbmc_ffdc.robot 9 10Test Setup Redfish.Login 11Test Teardown Run Keywords Redfish.Logout AND FFDC On Test Case Fail 12 13 14*** Variables *** 15 16${CMD_INTERNAL_FAILURE} busctl call xyz.openbmc_project.Logging /xyz/openbmc_project/logging 17... xyz.openbmc_project.Logging.Create Create ssa{ss} xyz.openbmc_project.Common.Error.InternalFailure 18... xyz.openbmc_project.Logging.Entry.Level.Error 0 19 20${CMD_FRU_CALLOUT} busctl call xyz.openbmc_project.Logging /xyz/openbmc_project/logging 21... xyz.openbmc_project.Logging.Create Create ssa{ss} xyz.openbmc_project.Common.Error.Timeout 22... xyz.openbmc_project.Logging.Entry.Level.Error 2 "TIMEOUT_IN_MSEC" "5" 23... "CALLOUT_INVENTORY_PATH" "/xyz/openbmc_project/inventory/system/chassis/motherboard" 24 25${CMD_PROCEDURAL_SYMBOLIC_FRU_CALLOUT} busctl call xyz.openbmc_project.Logging /xyz/openbmc_project/logging 26... xyz.openbmc_project.Logging.Create Create ssa{ss} org.open_power.Logging.Error.TestError1 27... xyz.openbmc_project.Logging.Entry.Level.Error 0 28 29${CMD_INFORMATIONAL_ERROR} busctl call xyz.openbmc_project.Logging /xyz/openbmc_project/logging 30... xyz.openbmc_project.Logging.Create Create ssa{ss} xyz.openbmc_project.Common.Error.TestError2 31... xyz.openbmc_project.Logging.Entry.Level.Informational 0 32 33${CMD_INVENTORY_PREFIX} busctl get-property xyz.openbmc_project.Inventory.Manager 34... /xyz/openbmc_project/inventory/system/chassis/motherboard 35 36${CMD_UNRECOVERABLE_ERROR} busctl call xyz.openbmc_project.Logging /xyz/openbmc_project/logging 37... xyz.openbmc_project.Logging.Create Create ssa{ss} xyz.openbmc_project.Common.Error.InternalFailure 38... xyz.openbmc_project.Logging.Entry.Level.Error 0 39 40${CMD_PREDICTIVE_ERROR} busctl call xyz.openbmc_project.Logging /xyz/openbmc_project/logging 41... xyz.openbmc_project.Logging.Create Create ssa{ss} xyz.openbmc_project.Common.Error.InternalFailure 42... xyz.openbmc_project.Logging.Entry.Level.Warning 0 43 44@{mandatory_pel_fileds} Private Header User Header Primary SRC Extended User Header Failing MTMS 45 46${info_log_max_usage_percentage} 15 47 48 49*** Test Cases *** 50 51Create Test PEL Log And Verify 52 [Documentation] Create PEL log using busctl command and verify via peltool. 53 [Tags] Create_Test_PEL_Log_And_Verify 54 55 Redfish Purge Event Log 56 Create Test PEL Log 57 ${pel_id}= Get PEL Log Via BMC CLI 58 Should Not Be Empty ${pel_id} msg=System PEL log entry is empty. 59 60 61Verify PEL Log Details 62 [Documentation] Verify PEL log details via peltool. 63 [Tags] Verify_PEL_Log_Details 64 65 Redfish Purge Event Log 66 67 ${bmc_time1}= CLI Get BMC DateTime 68 Create Test PEL Log 69 ${bmc_time2}= CLI Get BMC DateTime 70 71 ${pel_records}= Peltool -l 72 73 # Example output from 'Peltool -l': 74 # pel_records: 75 # [0x50000012]: 76 # [CreatorID]: BMC 77 # [CompID]: 0x1000 78 # [PLID]: 0x50000012 79 # [Subsystem]: BMC Firmware 80 # [Message]: An application had an internal failure 81 # [SRC]: BD8D1002 82 # [Commit Time]: 03/02/2020 09:35:15 83 # [Sev]: Unrecoverable Error 84 85 ${ids}= Get Dictionary Keys ${pel_records} 86 ${id}= Get From List ${ids} 0 87 88 @{pel_fields}= Create List CreatorID Subsystem Message Sev 89 FOR ${field} IN @{pel_fields} 90 Valid Value pel_records['${id}']['${field}'] ['${PEL_DETAILS['${field}']}'] 91 END 92 93 Valid Value pel_records['${id}']['PLID'] ['${id}'] 94 95 # Verify if "CompID" and "SRC" fields of PEL has alphanumeric value. 96 Should Match Regexp ${pel_records['${id}']['CompID']} [a-zA-Z0-9] 97 Should Match Regexp ${pel_records['${id}']['SRC']} [a-zA-Z0-9] 98 99 ${pel_date_time}= Convert Date ${pel_records['${id}']['Commit Time']} 100 ... date_format=%m/%d/%Y %H:%M:%S exclude_millis=yes 101 102 # Convert BMC and PEL time to epoch time before comparing. 103 ${bmc_time1_epoch}= Convert Date ${bmc_time1} epoch 104 ${pel_time_epoch}= Convert Date ${pel_date_time} epoch 105 ${bmc_time2_epoch}= Convert Date ${bmc_time2} epoch 106 107 Should Be True ${bmc_time1_epoch} <= ${pel_time_epoch} <= ${bmc_time2_epoch} 108 109 110Verify Mandatory Sections Of Error Log PEL 111 [Documentation] Verify mandatory sections of error log PEL. 112 [Tags] Verify_Mandatory_Sections_Of_Error_Log_PEL 113 114 Create Test PEL Log 115 116 ${pel_ids}= Get PEL Log Via BMC CLI 117 ${pel_id}= Get From List ${pel_ids} -1 118 ${pel_output}= Peltool -i ${pel_id} 119 ${pel_sections}= Get Dictionary Keys ${pel_output} 120 121 List Should Contain Sub List ${pel_sections} ${mandatory_pel_fileds} 122 123 124Verify PEL Log Persistence After BMC Reboot 125 [Documentation] Verify PEL log persistence after BMC reboot. 126 [Tags] Verify_PEL_Log_Persistence_After_BMC_Reboot 127 128 Create Test PEL Log 129 ${pel_before_reboot}= Get PEL Log Via BMC CLI 130 131 Redfish OBMC Reboot (off) 132 ${pel_after_reboot}= Get PEL Log Via BMC CLI 133 134 List Should Contain Sub List ${pel_after_reboot} ${pel_before_reboot} 135 136 137Verify PEL ID Numbering 138 [Documentation] Verify PEL ID numbering. 139 [Tags] Verify_PEL_ID_Numbering 140 141 Redfish Purge Event Log 142 Create Test PEL Log 143 Create Test PEL Log 144 145 ${pel_ids}= Get PEL Log Via BMC CLI 146 147 # Example of PEL IDs from PEL logs. 148 # [0x50000012]: <--- First PEL ID 149 # [CreatorID]: BMC 150 # [CompID]: 0x1000 151 # [PLID]: 0x50000012 152 # [Subsystem]: BMC Firmware 153 # [Message]: An application had an internal failure 154 # [SRC]: BD8D1002 155 # [Commit Time]: 03/02/2020 09:35:15 156 # [Sev]: Unrecoverable Error 157 # 158 # [0x50000013]: <--- Second PEL ID 159 # [CreatorID]: BMC 160 # [CompID]: 0x1000 161 # [PLID]: 0x50000013 162 # [Subsystem]: BMC Firmware 163 # [Message]: An application had an internal failure 164 # [SRC]: BD8D1002 165 # [Commit Time]: 03/02/2020 09:35:15 166 # [Sev]: Unrecoverable Error 167 168 Should Be True ${pel_ids[1]} == ${pel_ids[0]}+1 169 170Verify Machine Type Model And Serial Number 171 [Documentation] Verify machine type model and serial number from PEL. 172 [Tags] Verify_Machine_Type_Model_And_Serial_Number 173 174 Create Test PEL Log 175 176 ${pel_ids}= Get PEL Log Via BMC CLI 177 ${id}= Get From List ${pel_ids} -1 178 179 ${pel_serial_number}= Get PEL Field Value ${id} Failing MTMS Serial Number 180 ${pel_serial_number}= Replace String Using Regexp ${pel_serial_number} ^0+ ${EMPTY} 181 ${pel_machine_type_model}= Get PEL Field Value ${id} Failing MTMS Machine Type Model 182 ${pel_machine_type_model}= Replace String Using Regexp ${pel_machine_type_model} ^0+ ${EMPTY} 183 184 # Example of "Machine Type Model" and "Serial Number" fields value from "Failing MTMS" section of PEL. 185 # [Failing MTMS]: 186 # [Created by]: 0x2000 187 # [Machine Type Model]: 1234-ABC <---- Machine type 188 # [Section Version]: 1 189 # [Serial Number]: ABCDEFG <---- Serial number 190 # [Sub-section type]: 0 191 192 ${redfish_machine_model}= Redfish.Get Attribute /redfish/v1/Systems/system/ Model 193 ${redfish_machine_model}= Replace String Using Regexp ${redfish_machine_model} ^0+ ${EMPTY} 194 ${redfish_serial_number}= Redfish.Get Attribute /redfish/v1/Systems/system/ SerialNumber 195 ${redfish_serial_number}= Replace String Using Regexp ${redfish_serial_number} ^0+ ${EMPTY} 196 197 Valid Value pel_machine_type_model ['${redfish_machine_model}'] 198 Valid Value pel_serial_number ['${redfish_serial_number}'] 199 200 # Check "Machine Type Model" and "Serial Number" fields value from "Extended User Header" section of PEL. 201 ${pel_machine_type_model}= Get PEL Field Value ${id} Extended User Header Reporting Machine Type 202 ${pel_machine_type_model}= Replace String Using Regexp ${pel_machine_type_model} ^0+ ${EMPTY} 203 ${pel_serial_number}= Get PEL Field Value ${id} Extended User Header Reporting Serial Number 204 ${pel_serial_number}= Replace String Using Regexp ${pel_serial_number} ^0+ ${EMPTY} 205 206 Valid Value pel_machine_type_model ['${redfish_machine_model}'] 207 Valid Value pel_serial_number ['${redfish_serial_number}'] 208 209 210Verify Host Off State From PEL 211 [Documentation] Verify Host off state from PEL. 212 [Tags] Verify_Host_Off_State_From_PEL 213 214 Redfish Power Off stack_mode=skip 215 Create Test PEL Log 216 217 ${pel_ids}= Get PEL Log Via BMC CLI 218 ${id}= Get From List ${pel_ids} -1 219 ${pel_host_state}= Get PEL Field Value ${id} User Data HostState 220 221 Valid Value pel_host_state ['Off'] 222 223 224Verify BMC Version From PEL 225 [Documentation] Verify BMC Version from PEL. 226 [Tags] Verify_BMC_Version_From_PEL 227 228 Create Test PEL Log 229 230 ${pel_ids}= Get PEL Log Via BMC CLI 231 ${id}= Get From List ${pel_ids} -1 232 ${pel_bmc_version}= Get PEL Field Value ${id} User Data BMC Version ID 233 234 ${bmc_version}= Get BMC Version 235 Valid Value bmc_version ['${bmc_version}'] 236 237 238Verify PEL Log After Host Poweron 239 [Documentation] Verify PEL log generation while booting host. 240 [Tags] Verify_PEL_Log_After_Host_Poweron 241 242 Redfish Power Off stack_mode=skip 243 Redfish Purge Event Log 244 Redfish Power On stack_mode=skip 245 246 ${pel_informational_error}= Get PEL Log IDs User Header Event Severity Informational Event 247 ${pel_bmc_created_error}= Get PEL Log IDs Private Header Creator Subsystem BMC 248 249 # Get BMC created non-infomational error. 250 ${pel_bmc_error}= Subtract Lists ${pel_bmc_created_error} ${pel_informational_error} 251 252 Should Be Empty ${pel_bmc_error} msg=Unexpected error log generated during Host poweron. 253 254 255Verify BMC Event Log ID 256 [Documentation] Verify BMC Event Log ID from PEL. 257 [Tags] Verify_BMC_Event_Log_ID 258 259 Redfish Purge Event Log 260 Create Test PEL Log 261 262 ${pel_ids}= Get PEL Log Via BMC CLI 263 ${pel_bmc_event_log_id}= Get PEL Field Value ${pel_ids[0]} Private Header BMC Event Log Id 264 265 # Example "BMC Event Log Id" field value from "Private Header" section of PEL. 266 # [Private Header]: 267 # [Created at]: 08/24/1928 12:04:06 268 # [Created by]: 0x584D 269 # [Sub-section type]: 0 270 # [Entry Id]: 0x50000BB7 271 # [Platform Log Id]: 0x8200061D 272 # [CSSVER]: 273 # [Section Version]: 1 274 # [Creator Subsystem]: PHYP 275 # [BMC Event Log Id]: 341 <---- BMC event log id value 276 # [Committed at]: 03/25/1920 12:06:22 277 278 ${redfish_event_logs}= Redfish.Get Properties /redfish/v1/Systems/system/LogServices/EventLog/Entries 279 280 # Example of redfish_event_logs output: 281 # redfish_event_logs: 282 # [@odata.id]: /redfish/v1/Systems/system/LogServices/EventLog/Entries 283 # [Name]: System Event Log Entries 284 # [Members@odata.count]: 1 285 # [@odata.type]: #LogEntryCollection.LogEntryCollection 286 # [Description]: Collection of System Event Log Entries 287 # [Members]: 288 # [0]: 289 # [@odata.id]: /redfish/v1/Systems/system/LogServices/EventLog/Entries/235 290 # [Name]: System Event Log Entry 291 # [Severity]: Critical 292 # [EntryType]: Event 293 # [Created]: 2020-04-02T07:25:13+00:00 294 # [@odata.type]: #LogEntry.v1_5_1.LogEntry 295 # [Id]: 235 <----- Event log ID 296 # [Message]: xyz.openbmc_project.Common.Error.InternalFailure 297 298 Valid Value pel_bmc_event_log_id ['${redfish_event_logs['Members'][0]['Id']}'] 299 300 301Verify FRU Callout 302 [Documentation] Verify FRU callout entries from PEL log. 303 [Tags] Verify_FRU_Callout 304 305 Create Test PEL Log FRU Callout 306 307 ${pel_ids}= Get PEL Log Via BMC CLI 308 ${id}= Get From List ${pel_ids} -1 309 ${pel_callout_section}= Get PEL Field Value ${id} Primary SRC Callout Section 310 311 # Example of PEL Callout Section from "peltool -i <id>" command. 312 # [Callouts]: 313 # [0]: 314 # [FRU Type]: Normal Hardware FRU 315 # [Priority]: Mandatory, replace all with this type as a unit 316 # [Location Code]: U78DA.ND1.1234567-P0 317 # [Part Number]: F191014 318 # [CCIN]: 2E2D 319 # [Serial Number]: YL2E2D010000 320 # [Callout Count]: 1 321 322 Valid Value pel_callout_section['Callout Count'] ['1'] 323 Valid Value pel_callout_section['Callouts'][0]['FRU Type'] ['Normal Hardware FRU'] 324 Should Contain ${pel_callout_section['Callouts'][0]['Priority']} Mandatory 325 326 # Verify Location Code field of PEL callout with motherboard's Location Code. 327 ${busctl_output}= BMC Execute Command ${CMD_INVENTORY_PREFIX} com.ibm.ipzvpd.Location LocationCode 328 Should Be Equal ${pel_callout_section['Callouts'][0]['Location Code']} 329 ... ${busctl_output[0].split('"')[1].strip('"')} 330 331 # TODO: Compare CCIN and part number fields of PEL callout with Redfish or busctl output. 332 Should Match Regexp ${pel_callout_section['Callouts'][0]['CCIN']} [a-zA-Z0-9] 333 Should Match Regexp ${pel_callout_section['Callouts'][0]['Part Number']} [a-zA-Z0-9] 334 335 # Verify Serial Number field of PEL callout with motherboard's Serial Number. 336 ${busctl_output}= BMC Execute Command 337 ... ${CMD_INVENTORY_PREFIX} xyz.openbmc_project.Inventory.Decorator.Asset SerialNumber 338 Should Be Equal ${pel_callout_section['Callouts'][0]['Serial Number']} 339 ... ${busctl_output[0].split('"')[1].strip('"')} 340 341 342Verify Procedure And Symbolic FRU Callout 343 [Documentation] Verify procedure and symbolic FRU callout from PEL log. 344 [Tags] Verify_Procedure_And_Symbolic_FRU_Callout 345 346 Create Test PEL Log Procedure And Symbolic FRU Callout 347 348 ${pel_ids}= Get PEL Log Via BMC CLI 349 ${id}= Get From List ${pel_ids} -1 350 ${pel_callout_section}= Get PEL Field Value ${id} Primary SRC Callout Section 351 352 # Example of PEL Callout Section from "peltool -i <id>" command. 353 # [Callouts]: 354 # [0]: 355 # [Priority]: Mandatory, replace all with this type as a unit 356 # [Procedure Number]: BMCSP02 357 # [FRU Type]: Maintenance Procedure Required 358 # [1]: 359 # [Priority]: Medium Priority 360 # [Part Number]: SVCDOCS 361 # [FRU Type]: Symbolic FRU 362 # [Callout Count]: 2 363 364 Valid Value pel_callout_section['Callout Count'] ['2'] 365 366 # Verify procedural callout info. 367 368 Valid Value pel_callout_section['Callouts'][0]['FRU Type'] ['Maintenance Procedure Required'] 369 Should Contain ${pel_callout_section['Callouts'][0]['Priority']} Mandatory 370 # Verify if "Procedure Number" field of PEL has an alphanumeric value. 371 Should Match Regexp ${pel_callout_section['Callouts'][0]['Procedure']} [a-zA-Z0-9] 372 373 # Verify procedural callout info. 374 375 Valid Value pel_callout_section['Callouts'][1]['FRU Type'] ['Symbolic FRU'] 376 Should Contain ${pel_callout_section['Callouts'][1]['Priority']} Medium Priority 377 # Verify if "Part Number" field of Symbolic FRU has an alphanumeric value. 378 Should Match Regexp ${pel_callout_section['Callouts'][1]['Part Number']} [a-zA-Z0-9] 379 380 381Verify PEL Log Entry For Event Log 382 [Documentation] Create an event log and verify PEL log entry in BMC for the same. 383 [Tags] Verify_PEL_Log_Entry_For_Event_Log 384 385 Redfish Purge Event Log 386 # Create an internal failure error log. 387 BMC Execute Command ${CMD_INTERNAL_FAILURE} 388 389 ${elog_entry}= Get Event Logs 390 # Example of Redfish event logs: 391 # elog_entry: 392 # [0]: 393 # [Message]: xyz.openbmc_project.Common.Error.InternalFailure 394 # [Created]: 2020-04-20T01:55:22+00:00 395 # [Id]: 1 396 # [@odata.id]: /redfish/v1/Systems/system/LogServices/EventLog/Entries/1 397 # [@odata.type]: #LogEntry.v1_4_0.LogEntry 398 # [EntryType]: Event 399 # [Severity]: Critical 400 # [Name]: System Event Log Entry 401 402 ${redfish_log_time}= Convert Date ${elog_entry[0]["Created"]} epoch 403 404 ${pel_records}= Peltool -l 405 # Example output from 'Peltool -l': 406 # pel_records: 407 # [0x50000023]: 408 # [SRC]: BD8D1002 409 # [CreatorID]: BMC 410 # [Message]: An application had an internal failure 411 # [CompID]: 0x1000 412 # [PLID]: 0x50000023 413 # [Commit Time]: 04/20/2020 01:55:22 414 # [Subsystem]: BMC Firmware 415 # [Sev]: Unrecoverable Error 416 417 ${ids}= Get Dictionary Keys ${pel_records} 418 ${id}= Get From List ${ids} 0 419 ${pel_log_time}= Convert Date ${pel_records['${id}']['Commit Time']} epoch 420 ... date_format=%m/%d/%Y %H:%M:%S 421 422 # Verify that both Redfish event and PEL has log entry for internal error with same time stamp. 423 Should Contain Any ${pel_records['${id}']['Message']} internal failure ignore_case=True 424 Should Contain Any ${elog_entry[0]['Message']} InternalFailure ignore_case=True 425 426 Should Be Equal ${redfish_log_time} ${pel_log_time} 427 428 429Verify Delete All PEL 430 [Documentation] Verify deleting all PEL logs. 431 [Tags] Verify_Delete_All_PEL 432 433 Create Test PEL Log 434 Create Test PEL Log 435 Peltool --delete-all False 436 437 ${pel_ids}= Get PEL Log Via BMC CLI 438 Should Be Empty ${pel_ids} 439 440 441Verify Informational Error Log 442 [Documentation] Create an informational error log and verify. 443 [Tags] Verify_Informational_Error_Log 444 445 Redfish Purge Event Log 446 # Create an informational error log. 447 BMC Execute Command ${CMD_INFORMATIONAL_ERROR} 448 ${pel_records}= Peltool -lfh 449 450 # An example of information error log data: 451 # { 452 # "0x500006A0": { 453 # "SRC": "BD8D1002", 454 # "Message": "An application had an internal failure", 455 # "PLID": "0x500006A0", 456 # "CreatorID": "BMC", 457 # "Subsystem": "BMC Firmware", 458 # "Commit Time": "10/14/2020 11:41:38", 459 # "Sev": "Informational Event", 460 # "CompID": "0x1000" 461 # } 462 # } 463 464 ${ids}= Get Dictionary Keys ${pel_records} 465 ${id}= Get From List ${ids} 0 466 Should Contain ${pel_records['${id}']['Sev']} Informational 467 468 469Verify Predictable Error Log 470 [Documentation] Create a predictive error and verify. 471 [Tags] Verify_Predictable_Error_Log 472 473 # Create a predictable error log. 474 BMC Execute Command ${CMD_PREDICTIVE_ERROR} 475 ${pel_records}= Peltool -l 476 477 # An example of predictive error log data: 478 # { 479 # "0x5000069E": { 480 # "SRC": "BD8D1002", 481 # "Message": "An application had an internal failure", 482 # "PLID": "0x5000069E", 483 # "CreatorID": "BMC", 484 # "Subsystem": "BMC Firmware", 485 # "Commit Time": "10/14/2020 11:40:07", 486 # "Sev": "Predictive Error", 487 # "CompID": "0x1000" 488 # } 489 # } 490 491 ${pel_ids}= Get PEL Log Via BMC CLI 492 ${id}= Get From List ${pel_ids} -1 493 Should Contain ${pel_records['${id}']['Sev']} Predictive 494 495 496Verify Unrecoverable Error Log 497 [Documentation] Create an unrecoverable error and verify. 498 [Tags] Verify_Unrecoverable_Error_Log 499 500 # Create an internal failure error log. 501 BMC Execute Command ${CMD_UNRECOVERABLE_ERROR} 502 ${pel_records}= Peltool -l 503 504 # An example of unrecoverable error log data: 505 # { 506 # "0x50000CC5": { 507 # "SRC": "BD8D1002", 508 # "Message": "An application had an internal failure", 509 # "PLID": "0x50000CC5", 510 # "CreatorID": "BMC", 511 # "Subsystem": "BMC Firmware", 512 # "Commit Time": "04/01/2020 16:44:55", 513 # "Sev": "Unrecoverable Error", 514 # "CompID": "0x1000" 515 # } 516 # } 517 518 ${pel_ids}= Get PEL Log Via BMC CLI 519 ${id}= Get From List ${pel_ids} -1 520 Should Contain ${pel_records['${id}']['Sev']} Unrecoverable 521 522 523Verify Informational Error Log Size When Error Log Exceeds Limit 524 [Documentation] Verify informational error log size when informational log size exceeds limit. 525 [Tags] Verify_Informational_Error_Log_Error_Log_When_Size_Exceeds_Limit 526 527 # Initially remove all logs. 528 Redfish Purge Event Log 529 530 # Create 3001 information logs. 531 FOR ${LOG_COUNT} IN RANGE 0 3001 532 BMC Execute Command ${CMD_INFORMATIONAL_ERROR} 533 END 534 535 # Delay for BMC to perform log compression when log size exceeds. 536 Sleep 10s 537 538 # Check logsize and verify that disk usage is around 15%. 539 ${usage_percent}= Get Disk Usage For Error Logs 540 ${percent_diff}= Evaluate ${usage_percent} - ${info_log_max_usage_percentage} 541 ${percent_diff}= Evaluate abs(${percent_diff}) 542 Should Be True ${percent_diff} <= 0.5 543 544 545*** Keywords *** 546 547Get Disk Usage For Error Logs 548 [Documentation] Get disk usage percentage for error logs. 549 550 ${usage_output} ${stderr} ${rc}= BMC Execute Command du /var/lib/phosphor-logging/errors 551 552 ${usage_output}= Fetch From Left ${usage_output} \/ 553 554 # Covert disk usage unit from KB to MB. 555 ${usage_output}= Evaluate ${usage_output} / 1024 556 557 # Logging disk capacity limit is set to 20MB. So calculating the log usage percentage. 558 ${usage_percent}= Evaluate ${usage_output} / 20 * 100 559 560 [return] ${usage_percent} 561 562 563Create Test PEL Log 564 [Documentation] Generate test PEL log. 565 [Arguments] ${pel_type}=Internal Failure 566 567 # Description of argument(s): 568 # pel_type The PEL type (e.g. Internal Failure, FRU Callout, Procedural Callout). 569 570 # Test PEL log entry example: 571 # { 572 # "0x5000002D": { 573 # "SRC": "BD8D1002", 574 # "Message": "An application had an internal failure", 575 # "PLID": "0x5000002D", 576 # "CreatorID": "BMC", 577 # "Subsystem": "BMC Firmware", 578 # "Commit Time": "02/25/2020 04:47:09", 579 # "Sev": "Unrecoverable Error", 580 # "CompID": "0x1000" 581 # } 582 # } 583 584 Run Keyword If '${pel_type}' == 'Internal Failure' 585 ... BMC Execute Command ${CMD_INTERNAL_FAILURE} 586 ... ELSE IF '${pel_type}' == 'FRU Callout' 587 ... BMC Execute Command ${CMD_FRU_CALLOUT} 588 ... ELSE IF '${pel_type}' == 'Procedure And Symbolic FRU Callout' 589 ... BMC Execute Command ${CMD_PROCEDURAL_SYMBOLIC_FRU_CALLOUT} 590 591 592Get PEL Log IDs 593 [Documentation] Returns the list of PEL log IDs which contains given field's value. 594 [Arguments] ${pel_section} ${pel_field} @{pel_field_value} 595 596 # Description of argument(s): 597 # pel_section The section of PEL (e.g. Private Header, User Header). 598 # pel_field The PEL field (e.g. Event Severity, Event Type). 599 # pel_field_value The list of PEL's field value (e.g. Unrecoverable Error). 600 601 ${pel_ids}= Get PEL Log Via BMC CLI 602 @{pel_id_list}= Create List 603 604 FOR ${id} IN @{pel_ids} 605 ${pel_output}= Peltool -i ${id} 606 # Example of PEL output from "peltool -i <id>" command. 607 # [Private Header]: 608 # [Created at]: 08/24/1928 12:04:06 609 # [Created by]: 0x584D 610 # [Sub-section type]: 0 611 # [Entry Id]: 0x50000BB7 612 # [Platform Log Id]: 0x8200061D 613 # [CSSVER]: 614 # [Section Version]: 1 615 # [Creator Subsystem]: PHYP 616 # [BMC Event Log Id]: 341 617 # [Committed at]: 03/25/1920 12:06:22 618 # [User Header]: 619 # [Log Committed by]: 0x4552 620 # [Action Flags]: 621 # [0]: Report Externally 622 # [Subsystem]: I/O Subsystem 623 # [Event Type]: Miscellaneous, Informational Only 624 # [Sub-section type]: 0 625 # [Event Scope]: Entire Platform 626 # [Event Severity]: Informational Event 627 # [Host Transmission]: Not Sent 628 # [Section Version]: 1 629 630 ${pel_section_output}= Get From Dictionary ${pel_output} ${pel_section} 631 ${pel_field_output}= Get From Dictionary ${pel_section_output} ${pel_field} 632 Run Keyword If '${pel_field_output}' in @{pel_field_value} Append To List ${pel_id_list} ${id} 633 END 634 Sort List ${pel_id_list} 635 636 [Return] ${pel_id_list} 637 638 639Get PEL Log Via BMC CLI 640 [Documentation] Returns the list of PEL IDs using BMC CLI. 641 642 ${pel_records}= Peltool -l 643 ${ids}= Get Dictionary Keys ${pel_records} 644 Sort List ${ids} 645 646 [Return] ${ids} 647 648 649Get PEL Field Value 650 [Documentation] Returns the value of given PEL's field. 651 [Arguments] ${pel_id} ${pel_section} ${pel_field} 652 653 # Description of argument(s): 654 # pel_id The ID of PEL (e.g. 0x5000002D, 0x5000002E). 655 # pel_section The section of PEL (e.g. Private Header, User Header) 656 # pel_field The PEL field (e.g. Event Severity, Event Type). 657 658 ${pel_output}= Peltool -i ${pel_id} 659 660 # Example of PEL output from "peltool -i <id>" command. 661 # [Private Header]: 662 # [Created at]: 08/24/1928 12:04:06 663 # [Created by]: 0x584D 664 # [Sub-section type]: 0 665 # [Entry Id]: 0x50000BB7 666 # [Platform Log Id]: 0x8200061D 667 # [CSSVER]: 668 # [Section Version]: 1 669 # [Creator Subsystem]: PHYP 670 # [BMC Event Log Id]: 341 671 # [Committed at]: 03/25/1920 12:06:22 672 # [User Header]: 673 # [Log Committed by]: 0x4552 674 # [Action Flags]: 675 # [0]: Report Externally 676 # [Subsystem]: I/O Subsystem 677 # [Event Type]: Miscellaneous, Informational Only 678 # [Sub-section type]: 0 679 # [Event Scope]: Entire Platform 680 # [Event Severity]: Informational Event 681 # [Host Transmission]: Not Sent 682 # [Section Version]: 1 683 684 ${pel_section_output}= Get From Dictionary ${pel_output} ${pel_section} 685 ${pel_field_output}= Get From Dictionary ${pel_section_output} ${pel_field} 686 687 [Return] ${pel_field_output} 688