1*** Settings *** 2Documentation Utility keywords for FFDC 3 4Library String 5Library DateTime 6Library openbmc_ffdc_list.py 7Resource resource.txt 8Resource connection_client.robot 9Resource utils.robot 10 11*** Variables *** 12 13${PRINT_LINE} ------------------------------------------------------------------------ 14 15${MSG_INTRO} This report contains the following information: 16${MSG_DETAIL} ${\n}\t\t[ Detailed Logs Captured Section ] 17${HEADER_MSG} ${\n}\t\t--------------------------- 18... ${\n}\t\t FIRST FAILURE DATA CAPTURE 19... ${\n}\t\t--------------------------- 20${FOOTER_MSG} ${\n}${PRINT_LINE} ${\n} 21 22${FFDC_LOG_PATH} ${EXECDIR}${/}logs${/} 23${TEST_HISTORY} ${FFDC_LOG_PATH}${/}test_history.txt 24 25*** Keywords *** 26 27Get Test Dir and Name 28 [Documentation] SUITE_NAME and TEST_NAME are automatic variables 29 ... and is populated dynamically by the robot framework 30 ... during execution 31 ${suite_name}= Get strip string ${SUITE_NAME} 32 ${suite_name}= Catenate SEPARATOR= ${FFDC_TIME}_ ${suite_name} 33 ${test_name}= Get strip string ${TEST_NAME} 34 ${test_name}= Catenate SEPARATOR= ${FFDC_TIME}_ ${test_name} 35 [Return] ${suite_name} ${test_name} 36 37 38Create FFDC Directory 39 [Documentation] Creates directory and report file 40 Create Directory ${FFDC_DIR_PATH} 41 Create FFDC Report File 42 43 44Create FFDC Report File 45 [Documentation] Create a generic file name for ffdc 46 Set Suite Variable 47 ... ${FFDC_FILE_PATH} ${FFDC_DIR_PATH}${/}${FFDC_TIME}_BMC_general.txt 48 Create File ${FFDC_FILE_PATH} 49 50 51Write Data To File 52 [Documentation] Write data to the ffdc report document 53 [Arguments] ${data}= ${filepath}=${FFDC_FILE_PATH} 54 Append To File ${filepath} ${data} 55 56 57Get Current Time Stamp 58 [Documentation] Get the current time stamp data 59 ${cur_time}= Get Current Date result_format=%Y-%m-%d %H:%M:%S:%f 60 ${cur_time}= Get strip string ${cur_time} 61 [Return] ${cur_time} 62 63 64Header Message 65 [Documentation] Write header message to the report document manifest 66 ... and return a list of generated files. 67 ... TEST_NAME, TEST_MESSAGE,SUITE_SOURCE, TEST_DOCUMENTATION 68 ... are auto variables and are populated dynamically by the 69 ... robot framework during execution. 70 ... 1. Write opening statement headers message. 71 ... 2. Add test setup and config information. 72 ... 3. Print types of data collection. 73 74 ${TEST_NAME}= Get Variable Value ${TEST_NAME} 75 ${TEST_MESSAGE}= Get Variable Value ${TEST_MESSAGE} 76 ${TEST_DOCUMENTATION}= Get Variable Value ${TEST_DOCUMENTATION} 77 Write Data To File ${HEADER_MSG} 78 Write Data To File ${FOOTER_MSG} 79 Write Data To File Test Suite File\t\t: ${SUITE_NAME} ${\n} 80 Write Data To File Test Case Name\t\t: ${TEST_NAME}${\n} 81 Write Data To File Test Source File\t: ${SUITE_SOURCE}${\n} 82 Write Data To File Failure Time Stamp\t: ${FFDC_TIME}${\n} 83 Write Data To File Test Error Message\t: ${TEST_MESSAGE}${\n} 84 Write Data To File Test Documentation\t:${\n}${TEST_DOCUMENTATION}${\n} 85 Write Data To File ${FOOTER_MSG} 86 87 Test Setup Info 88 89 Write Data To File ${\n}${MSG_INTRO}${\n} 90 91 # --- FFDC header notes --- 92 @{entries}= Get ffdc cmd index 93 :FOR ${index} IN @{entries} 94 \ Write Data To File * ${index.upper()} 95 \ Write Data To File ${\n} 96 97 Write Data To File ${MSG_DETAIL} 98 ${ffdc_file_list}= Create List ${FFDC_FILE_PATH} 99 [Return] ${ffdc_file_list} 100 101 102Write Cmd Output to FFDC File 103 [Documentation] Write cmd output data to the report document 104 [Arguments] ${name_str} ${cmd} 105 106 Write Data To File ${FOOTER_MSG} 107 Write Data To File ${ENTRY_INDEX.upper()} : ${name_str}\t 108 Write Data To File Executed : ${cmd} 109 Write Data To File ${FOOTER_MSG} 110 111 112Test Setup Info 113 [Documentation] BMC IP, Model and other information 114 115 Write Data To File ${\n}-----------------------${\n} 116 Write Data To File Test Setup Information: 117 Write Data To File ${\n}-----------------------${\n} 118 Write Data To File OPENBMC HOST \t: ${OPENBMC_HOST}${\n} 119 ${model_name}= Get BMC System Model 120 Write Data To File SYSTEM TYPE \t: ${model_name} 121 122 123Error Logs Should Not Exist 124 [Documentation] Verify that error logs do not exist. 125 126 ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY}list quiet=${1} 127 Should Be Equal As Strings ${resp.status_code} ${HTTP_NOT_FOUND} 128 ... msg=Unexpected BMC error log(s) present. 129 130 131Error Logs Should Exist 132 [Documentation] Verify that error logs exist. 133 134 ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY}list quiet=${1} 135 Run Keyword If ${resp.status_code} != ${HTTP_OK} Fail 136 ... msg=Expected BMC error log(s) are not present. 137