1*** Settings *** 2 3Documentation Module to test IPMI network functionality. 4Resource ../lib/ipmi_client.robot 5Resource ../lib/openbmc_ffdc.robot 6Resource ../lib/bmc_network_utils.robot 7Resource ../lib/boot_utils.robot 8Library ../lib/ipmi_utils.py 9Library ../lib/gen_robot_valid.py 10Library ../lib/var_funcs.py 11Library ../lib/bmc_network_utils.py 12 13Suite Setup Suite Setup Execution 14Suite Teardown Redfish.Logout 15Test Setup Printn 16Test Teardown Test Teardown Execution 17 18Force Tags Ipmi_Network_Configuration 19 20 21*** Variables *** 22${vlan_id_for_ipmi} ${10} 23@{vlan_ids} ${20} ${30} 24${interface} eth0 25${ip} 10.0.0.1 26${initial_lan_config} &{EMPTY} 27${vlan_resource} ${NETWORK_MANAGER}action/VLAN 28${netmask} ${24} 29${gateway} 0.0.0.0 30${vlan_id_for_rest} ${30} 31 32 33*** Test Cases *** 34 35Verify IPMI Inband Network Configuration 36 [Documentation] Verify BMC network configuration via inband IPMI. 37 [Tags] Verify_IPMI_Inband_Network_Configuration 38 [Teardown] Run Keywords Restore Configuration AND FFDC On Test Case Fail 39 40 Redfish Power On 41 42 Set IPMI Inband Network Configuration ${STATIC_IP} ${NETMASK} ${GATEWAY} 43 Sleep 10 44 45 ${lan_print_output}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 46 Valid Value lan_print_output['IP Address'] ["${STATIC_IP}"] 47 Valid Value lan_print_output['Subnet Mask'] ["${NETMASK}"] 48 Valid Value lan_print_output['Default Gateway IP'] ["${GATEWAY}"] 49 50 51Disable VLAN Via IPMI When Multiple VLAN Exist On BMC 52 [Documentation] Disable VLAN Via IPMI When Multiple VLAN Exist On BMC. 53 [Tags] Disable_VLAN_Via_IPMI_When_Multiple_VLAN_Exist_On_BMC 54 55 FOR ${vlan_id} IN @{vlan_ids} 56 Create VLAN ${vlan_id} 57 END 58 59 Create VLAN Via IPMI off 60 61 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 62 Valid Value lan_config['802.1q VLAN ID'] ['Disabled'] 63 64 65Configure IP On VLAN Via IPMI 66 [Documentation] Configure IP On VLAN Via IPMI. 67 [Tags] Configure_IP_On_VLAN_Via_IPMI 68 69 Create VLAN Via IPMI ${vlan_id_for_ipmi} 70 71 Run Inband IPMI Standard Command 72 ... lan set ${CHANNEL_NUMBER} ipaddr ${ip} login_host=${0} 73 74 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 75 Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}'] 76 Valid Value lan_config['IP Address'] ["${ip}"] 77 78 79Create VLAN Via IPMI When LAN And VLAN Exist On BMC 80 [Documentation] Create VLAN Via IPMI When LAN And VLAN Exist On BMC. 81 [Tags] Create_VLAN_Via_IPMI_When_LAN_And_VLAN_Exist_On_BMC 82 [Setup] Create VLAN ${vlan_id_for_rest} 83 84 Create VLAN Via IPMI ${vlan_id_for_ipmi} 85 86 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 87 Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}'] 88 89 90Create VLAN Via IPMI And Verify 91 [Documentation] Create and verify VLAN via IPMI. 92 [Tags] Create_VLAN_Via_IPMI_And_Verify 93 94 Create VLAN Via IPMI ${vlan_id_for_ipmi} 95 96 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 97 Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}'] 98 Valid Value lan_config['IP Address'] ['${ip_address}'] 99 Valid Value lan_config['Subnet Mask'] ['${subnet_mask}'] 100 101Test Disabling Of VLAN Via IPMI 102 [Documentation] Disable VLAN and verify via IPMI. 103 [Tags] Test_Disabling_Of_VLAN_Via_IPMI 104 105 Create VLAN Via IPMI ${vlan_id_for_ipmi} 106 Create VLAN Via IPMI off 107 108 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 109 Valid Value lan_config['802.1q VLAN ID'] ['Disabled'] 110 111 112Create VLAN When LAN And VLAN Exist With IP Address Configured 113 [Documentation] Create VLAN when LAN and VLAN exist with IP address configured. 114 [Tags] Create_VLAN_When_LAN_And_VLAN_Exist_With_IP_Address_Configured 115 [Setup] Run Keywords Create VLAN ${vlan_id_for_rest} interface=${interface} 116 ... AND Configure Network Settings On VLAN ${vlan_id_for_rest} ${ip} 117 ... ${netmask} ${gateway} interface=${interface} 118 119 Create VLAN Via IPMI ${vlan_id_for_ipmi} 120 121 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 122 Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}'] 123 Valid Value lan_config['IP Address'] ['${ip}'] 124 125 126Create Multiple VLANs Via IPMI And Verify 127 [Documentation] Create multiple VLANs through IPMI. 128 [Tags] Create_Multiple_VLANs_Via_IPMI_And_Verify 129 130 FOR ${vlan_id} IN @{vlan_ids} 131 132 Create VLAN Via IPMI ${vlan_id} 133 134 ${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 135 136 # Validate VLAN creation. 137 Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id}'] 138 139 # Validate existing IP address. 140 Valid Value lan_config['IP Address'] ['${ip_address}'] 141 142 # Validate existing subnet mask. 143 Valid Value lan_config['Subnet Mask'] ['${subnet_mask}'] 144 END 145 146 147*** Keywords *** 148 149Create VLAN Via IPMI 150 [Documentation] Create VLAN via inband IPMI command. 151 [Arguments] ${vlan_id} ${channel_number}=${CHANNEL_NUMBER} 152 153 # Description of argument(s): 154 # vlan_id The VLAN ID (e.g. '10'). 155 156 Run Inband IPMI Standard Command 157 ... lan set ${channel_number} vlan id ${vlan_id} login_host=${0} 158 159 160Set IPMI Inband Network Configuration 161 [Documentation] Run sequence of standard IPMI command in-band and set 162 ... the IP configuration. 163 [Arguments] ${ip} ${netmask} ${gateway} ${login}=${1} 164 165 # Description of argument(s): 166 # ip The IP address to be set using ipmitool-inband. 167 # netmask The Netmask to be set using ipmitool-inband. 168 # gateway The Gateway address to be set using ipmitool-inband. 169 170 Run Inband IPMI Standard Command 171 ... lan set ${CHANNEL_NUMBER} ipsrc static login_host=${login} 172 Run Inband IPMI Standard Command 173 ... lan set ${CHANNEL_NUMBER} ipaddr ${ip} login_host=${0} 174 Run Inband IPMI Standard Command 175 ... lan set ${CHANNEL_NUMBER} netmask ${netmask} login_host=${0} 176 Run Inband IPMI Standard Command 177 ... lan set ${CHANNEL_NUMBER} defgw ipaddr ${gateway} login_host=${0} 178 179 180Restore Configuration 181 [Documentation] Restore the configuration to its pre-test state. 182 183 ${length}= Get Length ${initial_lan_config} 184 Return From Keyword If ${length} == ${0} 185 186 Set IPMI Inband Network Configuration ${ip_address} ${subnet_mask} 187 ... ${initial_lan_config['Default Gateway IP']} login=${0} 188 189 190Suite Setup Execution 191 [Documentation] Suite Setup Execution. 192 193 Redfish.Login 194 195 ${initial_lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband 196 Set Suite Variable ${initial_lan_config} 197 198 Run Inband IPMI Standard Command 199 ... lan set ${CHANNEL_NUMBER} ipsrc static login_host=${1} 200 201 ${host_name} ${ip_address}= Get Host Name IP host=${OPENBMC_HOST} 202 Set Suite Variable ${ip_address} 203 204 @{network_configurations}= Get Network Configuration 205 FOR ${network_configuration} IN @{network_configurations} 206 Run Keyword If '${network_configuration['Address']}' == '${ip_address}' 207 ... Run Keywords Set Suite Variable ${subnet_mask} ${network_configuration['SubnetMask']} AND 208 ... Exit For Loop 209 END 210 211Test Teardown Execution 212 [Documentation] Test Teardown Execution. 213 214 FFDC On Test Case Fail 215 Create VLAN Via IPMI off 216 Restore Configuration 217