1*** Settings *** 2Documentation This test suite will validate the "OpenBMC" GUI -> 3... "Server control" main menu -> "Server power 4... operations" submenu module. 5 6Resource ../../lib/resource.robot 7Test Setup Test Setup Execution ${OBMC_PowerOff_state} 8Test Teardown Test Teardown Execution 9 10*** Variables *** 11${xpath_select_server_control} //*[@id="nav__top-level"]/li[3]/button/span 12${xpath_select_server_power_operations} //a[@href='#/server-control/power-operations'] 13${string_server_power_operations} Server power operations 14${string_current_status} Current status 15${string_select_power_operation} Select a power operation 16${string_warm_reboot} Attempts to perform an orderly shutdown before restarting the server 17${string_cold_reboot} Shuts down the server immediately, then restarts it 18${string_orderly_shutdown} Attempts to stop all software on the server before removing power 19${string_immediate_shutdown} Removes power from the server without waiting for software to stop 20${string_power_on} Attempts to power on the server 21 22*** Test Case *** 23# OpenBMC @ Power Off state test cases. 24 25Verify Orderly Shutdown Button At Power Off 26 [Documentation] Verify orderly shutdown button is not present at power Off. 27 [Tags] Verify_Orderly_Shutdown_Button_At_Power_Off 28 29 Select Server Power Operations Sub Menu 30 Element Should Not Be Visible ${xpath_select_button_orderly_shutdown} 31 32 33Verify Immediate Shutdown Button At Power Off 34 [Documentation] Verify immediate shutdown button not present at power Off. 35 [Tags] Verify_Immediate_Shutdown_Button_At_Power_Off 36 37 Select Server Power Operations Sub Menu 38 Element Should Not Be Visible ${xpath_select_button_immediate_shutdown} 39 40 41Verify Warm Reboot Button At Power Off 42 [Documentation] Verify warm reboot button is not present at power Off. 43 [Tags] Verify_Warm_Reboot_Button_At_Power_Off 44 45 Select Server Power Operations Sub Menu 46 Element Should Not Be Visible ${xpath_select_button_warm_reboot} 47 48Verify Cold Reboot Button At Power Off 49 [Documentation] Verify cold reboot button is not present at power Off. 50 [Tags] Verify_Cold_Reboot_Button_At_Power_Off 51 52 Select Server Power Operations Sub Menu 53 Element Should Not Be Visible ${xpath_select_button_cold_reboot} 54 55Verify Title Text Should Be Server Power Operations At Power Off 56 [Documentation] Verify display of title text "Server Power Operations". 57 [Tags] Verify_Title_Text_Should_Be_Server_Power_Operations_At_Power_Off 58 ... OBMC_PowerOff_state 59 60 Select Server Power Operations Sub Menu 61 Verify Display Content ${string_server_power_operations} 62 63Verify Sub Title Text Should Be Current Status At Power Off 64 [Documentation] Verify display of title text "Current Status". 65 [Tags] Verify_Sub_Title_Text_Should_Be_Current_Status_At_Power_Off 66 ... OBMC_PowerOff_state 67 68 Select Server Power Operations Sub Menu 69 Verify Display Content ${string_current_status} 70 71Verify Sub Title Text Should Be Select Power Operation At Power Off 72 [Documentation] Verify display of title text "Select a power operation". 73 [Tags] Verify_Sub_Title_Text_Should_Be_Select_Power_Operation_At_Power_Off 74 ... OBMC_PowerOff_state 75 76 Select Server Power Operations Sub Menu 77 Verify Display Content ${string_Select_power_operation} 78 79Verify Power On Button Should Present At Power Off 80 [Documentation] Verify presence of "Warm reboot" button. 81 [Tags] Verify_Power_On_Button_Should_Present_At_Power_Off 82 ... OBMC_PowerOff_State 83 84 Select Server Power Operations Sub Menu 85 Verify Presence of Power Button And Text Info 86 ... ${xpath_select_button_power_on} ${string_power_on} 87 88Verify Power On At Power Off 89 [Documentation] Verify presence of "Warm reboot" button. 90 [Tags] Verify_Power_On_At_Power_Off 91 ... OBMC_PowerOff_State 92 93 Power On OpenBMC 94 95 96# OpenBMC @ Power Running state test cases. 97 98Verify Warm Reboot Button Should Present At Power Running 99 [Documentation] Verify presence of "Warm reboot" button. 100 [Tags] Verify_Warm_Reboot_Button_Should_Present_At_Power_Running 101 ... OBMC_PowerRunning_State 102 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 103 104 Select Server Power Operations Sub Menu 105 Verify Presence of Power Button And Text Info 106 ... ${xpath_select_button_warm_reboot} ${string_warm_reboot} 107 108Verify Cold Reboot Button Should Present At Power Running 109 [Documentation] Verify presence of "cold reboot" button. 110 [Tags] Verify_Cold_Reboot_Button_Should_Present_At_Power_Running 111 ... OBMC_PowerRunning_State 112 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 113 114 Select Server Power Operations Sub Menu 115 Verify Presence of Power Button And Text Info 116 ... ${xpath_select_button_cold_reboot} ${string_cold_reboot} 117 118Verify Orderly Shutdown Button Should Present At Power Running 119 [Documentation] Verify presence of "Orderly shutdow " button. 120 [Tags] Verify_Orderly_Shutdown_Button_Should_Present_At_Power_Running 121 ... OBMC_PowerRunning_State 122 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 123 124 Select Server Power Operations Sub Menu 125 Verify Presence of Power Button And Text Info 126 ... ${xpath_select_button_orderly_shutdown} ${string_orderly_shutdown} 127 128Verify Immediate Shutdown Button Should Present At Power Running 129 [Documentation] Verify presence of "Immediate shutdown" button. 130 [Tags] Verify_Immediate_Shutdown_Button_Should_Present_At_Power_Running 131 ... OBMC_PowerRunning_State 132 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 133 134 Select Server Power Operations Sub Menu 135 Verify Presence of Power Button And Text Info 136 ... ${xpath_select_button_immediate_shutdown} ${string_immediate_shutdown} 137 138Verify Warm Reboot Should Not Happen By Clicking No Button 139 [Documentation] Verify functionality of warm reboot "No" button clicking. 140 [Tags] Verify_Warm_Reboot_Should_Not_Happen_By_Clicking_No_Button 141 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 142 143 Select Server Power Operations Sub Menu 144 Click Element ${xpath_select_button_warm_reboot} 145 Verify Warning Message Display Text ${xpath_warm_reboot_warning_message} 146 ... ${text_warm_reboot_warning_message} 147 Verify No Button Functionality 148 ... ${xpath_select_button_warm_reboot_no} 149 150Verify Cold Reboot Should Not Happen By Clicking No Button 151 [Documentation] Verify functionality of cold reboot "No" button clicking. 152 [Tags] Verify_Cold_Reboot_Should_Not_Happen_By_Clicking_No_Button 153 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 154 155 Select Server Power Operations Sub Menu 156 Click Element ${xpath_select_button_cold_reboot} 157 Verify Warning Message Display Text ${xpath_cold_reboot_warning_message} 158 ... ${text_cold_reboot_warning_message} 159 Verify No Button Functionality 160 ... ${xpath_select_button_cold_reboot_no} 161 162Verify Orderly Shutdown Should Not Happen By Clicking No Button 163 [Documentation] Verify functionality of orderly shutdown "No" button clicking. 164 [Tags] Verify_Orderly_Shutdown_Should_Not_Happen_By_Clicking_No_Button 165 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 166 167 Select Server Power Operations Sub Menu 168 Click Element ${xpath_select_button_orderly_shutdown} 169 Verify Warning Message Display Text ${xpath_orderly_shutdown_warning_message} 170 ... ${text_orderly_shutdown_warning_message} 171 Verify No Button Functionality 172 ... ${xpath_select_button_orderly_shutdown_button_no} 173 174Verify Immediate Shutdown Should Not Happen By Clicking No Button 175 [Documentation] Verify functionality of immediate shutdown "No" button clicking. 176 [Tags] Verify_Immediate_Shutdown_Should_Not_Happen_By_Clicking_No_Button 177 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 178 179 Select Server Power Operations Sub Menu 180 Click Element ${xpath_select_button_immediate_shutdown} 181 Verify Warning Message Display Text ${xpath_immediate_shutdown_warning_message} 182 ... ${text_immediate_shutdown_warning_message} 183 Verify No Button Functionality 184 ... ${xpath_select_button_immediate_shutdown_no} 185 186Verify Warm Reboot Should Happen By Clicking Yes Button 187 [Documentation] Verify functionality of warm reboot "Yes" button clicking. 188 [Tags] Verify_Warm_Reboot_Should_Happen_By_Clicking_Yes_Button 189 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 190 191 Select Server Power Operations Sub Menu 192 Warm Reboot openBMC 193 194Verify Cold Reboot Should Happen By Clicking Yes Button 195 [Documentation] Verify functionality of cold reboot "Yes" button clicking. 196 [Tags] Verify_Cold_Reboot_Should_Happen_By_Clicking_Yes_Button 197 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 198 199 Select Server Power Operations Sub Menu 200 Cold Reboot openBMC 201 202Verify Orderly Shutdown Should Happen By Clicking Yes Button 203 [Documentation] Verify functionality of orderly shutdown "Yes" button clicking. 204 [Tags] Verify_Orderly_Shutdown_Should_Happen_By_Clicking_Yes_Button 205 ... OBMC_PowerRunning_State 206 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 207 208 Select Server Power Operations Sub Menu 209 Orderly Shutdown OpenBMC 210 211Verify Immediate Shutdown Should Happen By Clicking Yes Button 212 [Documentation] Verify functionality of immediate shutdown "Yes" button clicking. 213 [Tags] Verify_Immediate_Shutdown_Should_Happen_By_Clicking_Yes_Button 214 ... OBMC_PowerRunning_State 215 [Setup] Test Setup Execution ${OBMC_PowerRunning_state} 216 217 Select Server Power Operations Sub Menu 218 Immediate Shutdown openBMC 219 220*** Keywords *** 221Select Server Power Operations Sub Menu 222 [Documentation] Selecting of OpenBMC "Server Power Operations" Submenu. 223 224 Click Button ${xpath_select_server_control} 225 Click Button ${xpath_select_server_power_operations} 226 227Verify Presence of Power Button And Text Info 228 [Documentation] Verify the presens fo power button and text message info. 229 [Arguments] ${power_button} ${power_button_text} 230 231 # power_button Xpath of power button. 232 # power_button_text Text message info. 233 234 Page Should Contain Button ${power_button} 235 Verify Display Content ${power_button_text} 236 237Verify No Button Functionality 238 [Documentation] Verify the functionality of "No" button click. 239 [Arguments] ${xpath_no_button} 240 241 # xpath_no_button Xpath of "No" button. 242 243 Click No Button ${xpath_no_button} 244 ${obmc_current_state}= Get Text ${xpath_display_server_power_status} 245 Should Contain ${obmc_current_state} ${obmc_running_state} 246