1*** Settings *** 2 3Documentation Test OpenBMC GUI "Overview" menu. 4 5Resource ../../lib/gui_resource.robot 6Resource ../../../lib/logging_utils.robot 7Resource ../../../lib/list_utils.robot 8Resource ../../../lib/bmc_network_utils.robot 9 10Library String 11 12Suite Setup Launch Browser And Login GUI 13Suite Teardown Close Browser 14Test Setup Test Setup Execution 15 16 17*** Variables *** 18 19${xpath_overview_page_header} //h1[contains(text(), "Overview")] 20${xpath_edit_network_settings_button} (//*[text()="View more"])[3] 21${view_all_event_logs} (//*[text()="View more"])[5] 22${xpath_launch_serial_over_lan} //*[@data-test-id='overviewQuickLinks-button-solConsole'] 23${xpath_led_button} //*[@data-test-id='overviewInventory-checkbox-identifyLed'] 24 25 26*** Test Cases *** 27 28Verify Existence Of All Sections In Overview Page 29 [Documentation] Verify existence of all sections in Overview page. 30 [Tags] Verify_Existence_Of_All_Sections_In_Overview_Page 31 32 Page Should Contain BMC time 33 Page Should Contain Firmware information 34 Page Should Contain Server information 35 Wait Until Page Contains Network information timeout=10 36 Page Should Contain Power information 37 Page Should Contain Event logs 38 Page Should Contain Inventory and LEDs 39 40Verify Network Information In Overview Page 41 [Documentation] Verify values under network information section. 42 [Tags] Verify_Network_Information_In_Overview_Page 43 44 ${hostname}= Get BMC Hostname 45 Page Should Contain ${hostname} 46 47 # Get all IP addresses and prefix lengths on system. 48 49 ${ip_addr_list}= Get BMC IP Info 50 FOR ${ip_address} IN @{ip_addr_list} 51 ${ip}= Fetch From Left ${ip_address} \/ 52 Page Should Contain ${ip} 53 END 54 55 ${macaddr}= Get BMC MAC Address 56 Page Should Contain ${macaddr} 57 58 59Verify Message In High Priority Events Section For No Events 60 [Documentation] Verify message under high priority events section in case of no events. 61 [Tags] Verify_Message_In_High_Priority_Events_Section_For_No_Events 62 63 Redfish Purge Event Log 64 Click Element ${xpath_refresh_button} 65 Wait Until Page Contains no high priority events to display timeout=10 66 67 68Verify Server Information Section 69 [Documentation] Verify values under server information section in overview page. 70 [Tags] Verify_Server_Information_Section 71 72 ${redfish_machine_model}= Redfish.Get Attribute /redfish/v1/Systems/system/ Model 73 Page Should Contain ${redfish_machine_model} 74 75 ${redfish_serial_number}= Redfish.Get Attribute /redfish/v1/Systems/system/ SerialNumber 76 Page Should Contain ${redfish_serial_number} 77 78 ${redfish_motherboard_manufacturer}= Redfish.Get Attribute 79 ... /redfish/v1/Systems/system/ Manufacturer 80 81 Page Should Contain ${redfish_motherboard_manufacturer} 82 83 84Verify BMC Information Section 85 [Documentation] Verify BMC information section in overview page. 86 [Tags] Verify_BMC_Information_Section 87 88 ${firmware_version}= Redfish Get BMC Version 89 Page Should Contain ${firmware_version} 90 91 92Verify Edit Network Setting Button 93 [Documentation] Verify navigation to network setting page after clicking the button in overview page. 94 [Tags] Verify_Edit_Network_Setting_Button 95 96 Click Element ${xpath_edit_network_settings_button} 97 Wait Until Page Contains Element ${xpath_network_page_header} 98 99 100Verify Event Under High Priority Events Section 101 [Documentation] Verify event under high priority events section in case of any event. 102 [Tags] Verify_Event_Under_High_Priority_Events_Section 103 104 Redfish Purge Event Log 105 Click Element ${xpath_refresh_button} 106 Generate Test Error Log 107 Click Element ${xpath_refresh_button} 108 Wait Until Page Contains xyz.openbmc_project.Common.Error.InternalFailure timeout=30s 109 110 111Verify View All Event Logs Button 112 [Documentation] Verify view all event log button in overview page. 113 [Tags] Verify_View_All_Event_Logs_Button 114 115 Generate Test Error Log 116 Page Should Contain Element ${view_all_event_logs} timeout=30 117 Click Element ${view_all_event_logs} 118 Wait Until Page Contains Element ${xpath_event_header} timeout=30 119 120 121Verify Serial Over LAN Console Button In Overview Page 122 [Documentation] Click serial over LAN button and verify page navigation to serial over LAN page. 123 [Tags] Verify_Serial_Over_LAN_Console_Button_In_Overview_Page 124 125 Click Element ${xpath_launch_serial_over_lan} 126 Wait Until Page Contains Element ${xpath_sol_console_heading} 127 128 129Verify Server LED Turn On 130 [Documentation] Turn on server LED via GUI and verify its status via Redfish. 131 [Tags] Verify_Server_LED_Turn_On 132 133 # Turn Off the server LED via Redfish and refresh GUI. 134 Redfish.Patch /redfish/v1/Systems/system body={"IndicatorLED":"Off"} valid_status_codes=[200, 204] 135 Refresh GUI 136 137 # Turn ON the LED via GUI. 138 Click Element At Coordinates ${xpath_led_button} 0 0 139 140 # Cross check that server LED ON state via Redfish. 141 ${led_status}= Redfish.Get Attribute /redfish/v1/Systems/system IndicatorLED 142 Should Be True '${led_status}' == 'Lit' 143 144 145Verify Server LED Turn Off 146 [Documentation] Turn off server LED via GUI and verify its status via Redfish. 147 [Tags] Verify_Server_LED_Turn_Off 148 149 # Turn On the server LED via Redfish and refresh GUI. 150 Redfish.Patch /redfish/v1/Systems/system body={"IndicatorLED":"Lit"} valid_status_codes=[200, 204] 151 Refresh GUI 152 153 # Turn OFF the LED via GUI. 154 Click Element At Coordinates ${xpath_led_button} 0 0 155 156 # Cross check that server LED off state via Redfish. 157 ${led_status}= Redfish.Get Attribute /redfish/v1/Systems/system IndicatorLED 158 Should Be True '${led_status}' == 'Off' 159 160 161Verify BMC Time In Overview Page 162 [Documentation] Verify that BMC date from GUI matches with BMC time via Redfish. 163 [Tags] Verify_BMC_Time_In_Overview_Page 164 165 ${date_time}= Redfish.Get Attribute ${REDFISH_BASE_URI}Managers/bmc DateTime 166 ${converted_date}= Convert Date ${date_time} result_format=%Y-%m-%d 167 168 Page Should Contain ${converted_date} 169 170 171Verify BMC Information At Host Power Off State 172 [Documentation] Verify that BMC information is displayed at host power off state. 173 [Tags] Verify_BMC_Information_At_Host_Power_Off_State 174 175 Redfish Power Off stack_mode=skip 176 ${firmware_version}= Redfish Get BMC Version 177 Page Should Contain ${firmware_version} 178 179 180*** Keywords *** 181 182Test Setup Execution 183 [Documentation] Do test case setup tasks. 184 185 Click Element ${xpath_overview_menu} 186 Wait Until Page Contains Element ${xpath_overview_page_header} 187