1*** Settings *** 2 3Documentation Test OpenBMC GUI "Server power operations" sub-menu of "Operations". 4 5Resource ../../lib/gui_resource.robot 6Resource ../../../lib/state_manager.robot 7 8Test Setup Run Keywords Launch Browser And Login GUI AND Navigate to Server Power Operation Page 9Test Teardown Close Browser 10 11 12*** Variables *** 13 14${xpath_server_power_heading} //h1[text()="Server power operations"] 15${xpath_enable_onetime_boot_checkbox} //*[contains(@class,'custom-checkbox')] 16${xpath_boot_option_select} //*[@id='boot-option'] 17${xpath_shutdown_button} //*[@data-test-id='serverPowerOperations-button-shutDown'] 18${xpath_reboot_button} //*[@data-test-id='serverPowerOperations-button-reboot'] 19${xpath_poweron_button} //*[@data-test-id='serverPowerOperations-button-powerOn'] 20${xpath_save_button} //button[contains(text(),'Save')] 21${xpath_shutdown_orderly_radio} //*[@data-test-id='serverPowerOperations-radio-shutdownOrderly'] 22${xpath_shutdown_immediate_radio} //*[@data-test-id='serverPowerOperations-radio-shutdownImmediate'] 23${xpath_confirm_button} //button[contains(text(),'Confirm')] 24${xpath_current_power_state} //*[@data-test-id='powerServerOps-text-hostStatus'] 25${xpath_reboot_immediate_radio} //*[@data-test-id='serverPowerOperations-radio-rebootImmediate'] 26 27 28*** Test Cases *** 29 30Verify Navigation To Server Power Operations Page 31 [Documentation] Verify navigation to server power operations page. 32 [Tags] Verify_Navigation_To_Server_Power_Operations_Page 33 34 Page Should Contain Element ${xpath_server_power_heading} 35 36 37Verify Immediate Shutdown 38 [Documentation] Verify shutdown after clicking immediate shutdown button. 39 [Tags] Verify_Immediate_Shutdown 40 [Setup] Run Keywords Redfish Power On stack_mode=skip AND Launch Browser And Login GUI 41 ... AND Navigate to Server Power Operation Page 42 43 Click Element At Coordinates ${xpath_shutdown_immediate_radio} 0 0 44 Click Element ${xpath_shutdown_button} 45 Wait Until Page Contains Element ${xpath_confirm_button} timeout=10 46 Click Element ${xpath_confirm_button} 47 Wait Until Keyword Succeeds 3 min 15 sec Element Should Contain ${xpath_current_power_state} Off 48 49 50Verify Orderly Shutdown 51 [Documentation] Verify shutdown after clicking orderly shutdown button. 52 [Tags] Verify_Orderly_Shutdown 53 [Setup] Run Keywords Redfish Power On stack_mode=skip AND Launch Browser And Login GUI 54 ... AND Navigate to Server Power Operation Page 55 56 Click Element At Coordinates ${xpath_shutdown_orderly_radio} 0 0 57 Click Element ${xpath_shutdown_button} 58 Wait Until Page Contains Element ${xpath_confirm_button} timeout=10 59 Click Element ${xpath_confirm_button} 60 Wait Until Keyword Succeeds 10 min 15 sec Element Should Contain ${xpath_current_power_state} Off 61 62 63Verify Existence Of All Sections In Server Power Operations Page 64 [Documentation] Verify existence of all sections in Server Power Operations page. 65 [Tags] Verify_Existence_Of_All_Sections_In_Server_Power_Operations_Page 66 67 # Added a delay for the page to load boot settings section. 68 Wait Until Page Contains Server power operations timeout=5 69 Page Should Contain Current status 70 Page Should Contain Operations 71 Page Should Contain Settings 72 73 74Verify Existence Of All Input Boxes In Host Os Boot Settings 75 [Documentation] Verify existence of all input boxes in host os boot settings. 76 [Tags] Verify_Existence_Of_All_Input_Boxes_In_Host_Os_Boot_Settings 77 78 # Added a delay for the page to load boot settings section. 79 Wait Until Page Contains Boot settings timeout=5 80 Page Should Contain Element ${xpath_enable_onetime_boot_checkbox} 81 Page Should Contain Element ${xpath_boot_option_select} 82 83 84Verify System State At Power Off 85 [Documentation] Verify state of the system in power off state. 86 [Tags] Verify_System_State_At_Power_Off 87 88 Redfish Power Off stack_mode=skip 89 Page Should Contain Element ${xpath_current_power_state} 90 Element Should Contain ${xpath_current_power_state} Off 91 92 93Verify System State At Power On 94 [Documentation] Verify state of the system in power on state. 95 [Tags] Verify_System_State_At_Power_On 96 [Setup] Run Keywords Redfish Power On stack_mode=skip AND Launch Browser And Login GUI 97 ... AND Navigate to Server Power Operation Page 98 99 Wait Until Keyword Succeeds 15 sec 5 sec Element Should Contain ${xpath_current_power_state} On 100 101 102Verify PowerOn Button Should Present At Power Off 103 [Documentation] Verify existence of poweron button at power off. 104 [Tags] Verify_PowerOn_Button_Should_Present_At_Power_Off 105 106 Redfish Power Off stack_mode=skip 107 # TODO: Implement power off using GUI later. 108 Page Should Contain Element ${xpath_poweron_button} 109 110 111Verify Shutdown And Reboot Buttons Presence At Power On 112 [Documentation] Verify existence of shutdown and reboot buttons at power on. 113 [Tags] Verify_Shutdown_And_Reboot_Buttons_Presence_At_Power_On 114 [Setup] Run Keywords Redfish Power On stack_mode=skip AND Launch Browser And Login GUI 115 ... AND Navigate to Server Power Operation Page 116 117 # TODO: Implement power on using GUI later. 118 Page Should Contain Element ${xpath_shutdown_button} 119 Page Should Contain Element ${xpath_reboot_button} 120 121 122Verify Host Immediate Reboot 123 [Documentation] Verify host reboot after triggering immediate reboot. 124 [Tags] Verify_Host_Immediate_Reboot 125 [Setup] Run Keywords Redfish Power On stack_mode=skip AND Launch Browser And Login GUI 126 ... AND Navigate to Server Power Operation Page 127 128 Click Element At Coordinates ${xpath_reboot_immediate_radio} 0 0 129 Click Element ${xpath_reboot_button} 130 Wait Until Page Contains Element ${xpath_confirm_button} timeout=10 131 Click Element ${xpath_confirm_button} 132 Wait Until Keyword Succeeds 3 min 2 sec Element Should Contain ${xpath_current_power_state} Off 133 Click Element ${xpath_refresh_button} 134 Wait Until Keyword Succeeds 10 min 15 sec Element Should Contain ${xpath_current_power_state} On 135 136 137Verify Host Orderly Reboot 138 [Documentation] Verify host reboot after triggering orderly reboot. 139 [Tags] Verify_Host_Orderly_Reboot 140 [Setup] Run Keywords Redfish Power On stack_mode=skip AND Launch Browser And Login GUI 141 ... AND Navigate to Server Power Operation Page 142 143 Click Element ${xpath_reboot_button} 144 Wait Until Page Contains Element ${xpath_confirm_button} timeout=10 145 Click Element ${xpath_confirm_button} 146 Wait Until Keyword Succeeds 3 min 2 sec Element Should Contain ${xpath_current_power_state} Off 147 Click Element ${xpath_refresh_button} 148 Wait Until Keyword Succeeds 10 min 15 sec Element Should Contain ${xpath_current_power_state} On 149 150 151*** Keywords *** 152 153Navigate to Server Power Operation Page 154 [Documentation] Go to server power operation page. 155 156 Click Element ${xpath_operations_menu} 157 Click Element ${xpath_server_power_operations_sub_menu} 158 Wait Until Keyword Succeeds 30 sec 10 sec Location Should Contain server-power-operations 159 Wait Until Element Is Not Visible ${xpath_page_loading_progress_bar} timeout=30 160