1*** Settings *** 2Documentation This module will take whatever action is necessary 3... to bring the BMC to a stable, standby state. For our 4... purposes, a stable state is defined as: 5... - BMC is communicating 6... (pinging, sshing and REST commands working) 7... - Power state is 0 (off) 8... - BMC state is "Ready" 9... - HOST state is "Off" 10... - Boot policy is "ALWAYS_POWER_OFF" 11... Power cycle system via PDU if specified 12... Prune archived journal logs 13 14Resource ../lib/utils.robot 15Resource ../lib/pdu/pdu.robot 16Resource ../lib/state_manager.robot 17Resource ../lib/bmc_network_utils.robot 18Resource ../lib/bmc_cleanup.robot 19Resource ../lib/dump_utils.robot 20Resource ../lib/bmc_redfish_resource.robot 21Resource ../lib/bmc_redfish_utils.robot 22Library ../lib/gen_misc.py 23 24*** Variables *** 25${HOST_SETTING} /org/openbmc/settings/host0 26 27${ERROR_REGEX} xyz.openbmc_project.Software.BMC.Updater.service: Failed with result 'core-dump' 28 29*** Test Cases *** 30 31Get To Stable State 32 [Documentation] BMC cleanup drive to stable state 33 ... 1. PDU powercycle if specified 34 ... 1. Ping Test 35 ... 2. SSH Connection session Test 36 ... 3. REST Connection session Test 37 ... 4. Reboot BMC if REST Test failed 38 ... 5. Get BMC in Ready state if its not in this state 39 ... 6. Get Host in Off state if its not in this state 40 ... 7. Update restore policy 41 ... 8. Verify and Update MAC address. 42 [Tags] Get_To_Stable_State 43 44 Run Keyword And Ignore Error Powercycle System Via PDU 45 46 ${ping_status}= Run Keyword And Return Status 47 ... Wait For Host To Ping ${OPENBMC_HOST} 2 mins 48 49 # Check if the ping works using 1400 MTU. 50 Run Keyword if ${ping_status} == ${True} MTU Ping Test 51 52 Run Keyword if ${ping_status} == ${False} 53 ... Fail ${OPENBMC_HOST} ping test failed. 54 55 Open Connection And Log In host=${OPENBMC_HOST} 56 57 Wait Until Keyword Succeeds 58 ... 1 min 30 sec Initialize OpenBMC 59 60 ${ready_status}= Run Keyword And Return Status Is BMC Ready 61 Run Keyword If '${ready_status}' == '${False}' Put BMC State Ready 62 63 ${host_off_status}= Run Keyword And Return Status Is Host Off 64 Run Keyword If '${host_off_status}' == '${False}' Initiate Host PowerOff 65 66 Prune Journal Log 67 68 Run Keyword And Ignore Error Set BMC Power Policy ${ALWAYS_POWER_OFF} 69 70 # TODO: Enable MAC AES check latter. 71 # Reference : openbmc/openbmc-test-automation#998 72 #Run Keyword If '${MAC_ADDRESS}' != '${EMPTY}' 73 #... Check And Reset MAC 74 75 # TODO: Add new UBI File system cleanup. 76 # Reference : openbmc/openbmc-test-automation#998 77 #${rc}= Execute Command find ${CLEANUP_DIR_PATH} 78 #... return_stdout=False return_rc=True 79 #Run Keyword If '${CLEANUP_DIR_PATH}' != '${EMPTY}' and ${rc} == 0 80 #... Cleanup Dir 81 82 Run Keyword And Ignore Error Delete All Error Logs 83 Run Keyword And Ignore Error Redfish Purge Event Log 84 Run Keyword And Ignore Error Delete All Dumps 85 Run Keyword And Ignore Error Delete All Redfish Sessions 86 Check For Current Boot Application Failures 87 88*** Keywords *** 89 90BMC Online Test 91 [Documentation] BMC ping, SSH, REST connection Test 92 93 ${l_status}= Run Keyword and Return Status 94 ... Verify Ping and REST Authentication 95 Run Keyword If '${l_status}' == '${False}' 96 ... Fail msg=System not in ideal state to continue [ERROR] 97 98 99Update Policy Setting 100 [Documentation] Update the given restore policy 101 [Arguments] ${policy} 102 103 ${valueDict}= create dictionary data=${policy} 104 Write Attribute ${HOST_SETTING} power_policy data=${valueDict} 105 ${currentPolicy}= Read Attribute ${HOST_SETTING} power_policy 106 Should Be Equal ${currentPolicy} ${policy} 107 108 109Trigger Warm Reset via Reboot 110 [Documentation] Execute reboot command on the remote BMC and 111 ... returns immediately. This keyword "Start Command" 112 ... returns nothing and does not wait for the command 113 ... execution to be finished. 114 Open Connection And Log In 115 116 Start Command /sbin/reboot 117 118 119Powercycle System Via PDU 120 [Documentation] AC cycle the system via PDU. 121 122 Validate Parameters 123 PDU Power Cycle 124 Check If BMC is Up 5 min 10 sec 125 126 127Check For Current Boot Application Failures 128 [Documentation] Parse the journal log and check for failures. 129 [Arguments] ${error_regex}=${ERROR_REGEX} 130 131 ${error_regex}= Escape Bash Quotes ${error_regex} 132 ${journal_log} ${stderr} ${rc}= BMC Execute Command 133 ... journalctl -b --no-pager | egrep '${error_regex}' ignore_err=1 134 135 Should Be Empty ${journal_log} 136 137 138Validate Parameters 139 [Documentation] Validate PDU parameters. 140 Should Not Be Empty ${PDU_IP} 141 Should Not Be Empty ${PDU_TYPE} 142 Should Not Be Empty ${PDU_SLOT_NO} 143 Should Not Be Empty ${PDU_USERNAME} 144 Should Not Be Empty ${PDU_PASSWORD} 145 146 147MTU Ping Test 148 [Documentation] Ping test using MTU. 149 [Arguments] ${mtu}=${1400} 150 151 # Description of argument(s): 152 # mtu The maximum transmission unit (MTU) of a network interface. 153 154 ${rc} ${output}= Run And Return RC And Output 155 ... ping -M do -s ${mtu} -c 10 ${OPENBMC_HOST} 156 Should Be Equal As Integers ${rc} 0 157 Should Not Contain ${output} 100% packet loss 158