1*** Settings *** 2Documentation This module will take whatever action is necessary 3... to bring the BMC to a stable, standby state. For our 4... purposes, a stable state is defined as: 5... - BMC is communicating 6... (pinging, sshing and REST commands working) 7... - Power state is 0 (off) 8... - BMC state is "Ready" 9... - HOST state is "Off" 10... - Boot policy is "ALWAYS_POWER_OFF" 11... Power cycle system via PDU if specified 12... Prune archived journal logs 13 14Resource ../lib/utils.robot 15Resource ../lib/pdu/pdu.robot 16Resource ../lib/state_manager.robot 17Resource ../lib/bmc_network_utils.robot 18Resource ../lib/bmc_cleanup.robot 19Resource ../lib/dump_utils.robot 20Resource ../lib/bmc_redfish_resource.robot 21Resource ../lib/bmc_redfish_utils.robot 22Library ../lib/gen_misc.py 23 24*** Variables *** 25${HOST_SETTING} /org/openbmc/settings/host0 26 27${ERROR_REGEX} xyz.openbmc_project.Software.BMC.Updater.service: Failed with result 'core-dump' 28 29*** Test Cases *** 30 31Get To Stable State 32 [Documentation] BMC cleanup drive to stable state 33 ... 1. PDU powercycle if specified 34 ... 1. Ping Test 35 ... 2. SSH Connection session Test 36 ... 3. REST Connection session Test 37 ... 4. Reboot BMC if REST Test failed 38 ... 5. Get BMC in Ready state if its not in this state 39 ... 6. Get Host in Off state if its not in this state 40 ... 7. Update restore policy 41 ... 8. Verify and Update MAC address. 42 [Tags] Get_To_Stable_State 43 44 Run Keyword And Ignore Error Powercycle System Via PDU 45 46 ${ping_status}= Run Keyword And Return Status 47 ... Wait For Host To Ping ${OPENBMC_HOST} 2 mins 48 49 # Check if the ping works using 1400 MTU. 50 Run Keyword if ${ping_status} == ${True} MTU Ping Test 51 52 Run Keyword if ${ping_status} == ${False} 53 ... Fail ${OPENBMC_HOST} ping test failed. 54 55 Open Connection And Log In host=${OPENBMC_HOST} 56 57 Run Keyword If ${REDFISH_SUPPORTED} Redfish.Login 58 59 Wait Until Keyword Succeeds 60 ... 1 min 30 sec Initialize OpenBMC 61 62 ${ready_status}= Run Keyword And Return Status Is BMC Ready 63 Run Keyword If '${ready_status}' == '${False}' Put BMC State Ready 64 65 ${host_off_status}= Run Keyword And Return Status Is Host Off 66 Run Keyword If '${host_off_status}' == '${False}' Initiate Host PowerOff 67 68 Prune Journal Log 69 70 Run Keyword And Ignore Error Set BMC Power Policy ${ALWAYS_POWER_OFF} 71 Run Keyword And Ignore Error Redfish Set Power Restore Policy AlwaysOff 72 73 # TODO: Enable MAC AES check latter. 74 # Reference : openbmc/openbmc-test-automation#998 75 #Run Keyword If '${MAC_ADDRESS}' != '${EMPTY}' 76 #... Check And Reset MAC 77 78 # TODO: Add new UBI File system cleanup. 79 # Reference : openbmc/openbmc-test-automation#998 80 #${rc}= Execute Command find ${CLEANUP_DIR_PATH} 81 #... return_stdout=False return_rc=True 82 #Run Keyword If '${CLEANUP_DIR_PATH}' != '${EMPTY}' and ${rc} == 0 83 #... Cleanup Dir 84 85 Run Keyword And Ignore Error Delete All Error Logs 86 Run Keyword And Ignore Error Redfish Purge Event Log 87 Run Keyword And Ignore Error Delete All Dumps 88 Run Keyword And Ignore Error Delete All Redfish Sessions 89 Check For Current Boot Application Failures 90 91*** Keywords *** 92 93BMC Online Test 94 [Documentation] BMC ping, SSH, REST connection Test 95 96 ${l_status}= Run Keyword and Return Status 97 ... Verify Ping and REST Authentication 98 Run Keyword If '${l_status}' == '${False}' 99 ... Fail msg=System not in ideal state to continue [ERROR] 100 101 102Update Policy Setting 103 [Documentation] Update the given restore policy 104 [Arguments] ${policy} 105 106 ${valueDict}= create dictionary data=${policy} 107 Write Attribute ${HOST_SETTING} power_policy data=${valueDict} 108 ${currentPolicy}= Read Attribute ${HOST_SETTING} power_policy 109 Should Be Equal ${currentPolicy} ${policy} 110 111 112Trigger Warm Reset via Reboot 113 [Documentation] Execute reboot command on the remote BMC and 114 ... returns immediately. This keyword "Start Command" 115 ... returns nothing and does not wait for the command 116 ... execution to be finished. 117 Open Connection And Log In 118 119 Start Command /sbin/reboot 120 121 122Powercycle System Via PDU 123 [Documentation] AC cycle the system via PDU. 124 125 Validate Parameters 126 PDU Power Cycle 127 Check If BMC is Up 5 min 10 sec 128 129 130Check For Current Boot Application Failures 131 [Documentation] Parse the journal log and check for failures. 132 [Arguments] ${error_regex}=${ERROR_REGEX} 133 134 ${error_regex}= Escape Bash Quotes ${error_regex} 135 ${journal_log} ${stderr} ${rc}= BMC Execute Command 136 ... journalctl -b --no-pager | egrep '${error_regex}' ignore_err=1 137 138 Should Be Empty ${journal_log} 139 140 141Validate Parameters 142 [Documentation] Validate PDU parameters. 143 Should Not Be Empty ${PDU_IP} 144 Should Not Be Empty ${PDU_TYPE} 145 Should Not Be Empty ${PDU_SLOT_NO} 146 Should Not Be Empty ${PDU_USERNAME} 147 Should Not Be Empty ${PDU_PASSWORD} 148 149 150MTU Ping Test 151 [Documentation] Ping test using MTU. 152 [Arguments] ${mtu}=${1400} 153 154 # Description of argument(s): 155 # mtu The maximum transmission unit (MTU) of a network interface. 156 157 ${rc} ${output}= Run And Return RC And Output 158 ... ping -M do -s ${mtu} -c 10 ${OPENBMC_HOST} 159 Should Be Equal As Integers ${rc} 0 160 Should Not Contain ${output} 100% packet loss 161