1*** Settings ***
2Documentation     Update the PNOR code on a target BMC.
3...               Execution Method:
4...               python -m robot -v OPENBMC_HOST:<hostname>
5...               -v DELETE_OLD_PNOR_IMAGES:<"true" or "false">
6...               -v IMAGE_FILE_PATH:<path/*.tar>
7...               -v ALTERNATE_IMAGE_FILE_PATH:<path/*.tar>
8...               host_code_update.robot
9...
10...               Code update method BMC
11...               Update work flow sequence:
12...                 - Upload image via REST
13...                 - Verify that the file exists on the BMC
14...                 - Check that software "Activation" is set to "Ready"
15...                 - Set "Requested Activation" to "Active"
16...                 - Wait for code update to complete
17...                 - Verify the new version
18
19Library           ../../lib/bmc_ssh_utils.py
20Library           ../../lib/code_update_utils.py
21Variables         ../../data/variables.py
22Resource          ../../lib/boot_utils.robot
23Resource          code_update_utils.robot
24Resource          ../../lib/code_update_utils.robot
25Resource          ../../lib/openbmc_ffdc.robot
26Resource          ../../lib/state_manager.robot
27Resource          ../../lib/dump_utils.robot
28
29Test Teardown     Code Update Test Teardown
30
31Force Tags        Host_Code_Update
32
33*** Variables ***
34
35${QUIET}                          ${1}
36${IMAGE_FILE_PATH}                ${EMPTY}
37${DELETE_OLD_PNOR_IMAGES}         false
38${DELETE_OLD_GUARD_FILE}          false
39${ALTERNATE_IMAGE_FILE_PATH}      ${EMPTY}
40
41*** Test Cases ***
42
43REST Host Code Update
44    [Documentation]  Do a PNOR code update by uploading image on BMC via REST.
45    # 1. Delete error logs if there is any.
46    # 1. Do code update.
47    # 2. Do post update the following:
48    #    - Collect FFDC if error log exist and delete error logs.
49    [Tags]  REST_Host_Code_Update
50    [Setup]  Code Update Setup
51
52    Upload And Activate Image  ${IMAGE_FILE_PATH}
53    OBMC Reboot (off)
54
55
56Post Update Boot To OS
57    [Documentation]  Boot the host OS
58    [Tags]  Post_Update_Boot_To_OS
59    [Setup]  Start SOL Console Logging
60    [Teardown]  Run Keywords  Stop SOL Console Logging
61    ...         AND  Code Update Test Teardown
62
63    Run Keyword If  '${PREV_TEST_STATUS}' == 'FAIL'
64    ...  Fail  Code update failed. No need to boot to OS.
65    Delete Error Logs
66    REST Power On
67    Verify Running Host Image  ${IMAGE_FILE_PATH}
68
69
70REST Host Code Update While OS Is Running
71    [Documentation]  Do a PNOR code update while the host is running.
72    [Tags]  REST_Host_Code_Update_While_OS_Is_Running
73    [Teardown]  Run Keywords  REST Power Off  stack_mode=skip
74    ...         AND  Code Update Test Teardown
75
76    Run Keyword If  '${PREV_TEST_STATUS}' == 'FAIL'
77    ...  Fail  Cannot boot the OS.
78
79    REST Power On  stack_mode=skip
80    Upload And Activate Image  ${ALTERNATE_IMAGE_FILE_PATH}
81    REST Power On  stack_mode=normal
82    Verify Running Host Image  ${ALTERNATE_IMAGE_FILE_PATH}
83
84Host Image Priority Attribute Test
85    [Documentation]  Set "Priority" attribute.
86    [Tags]  Host_Image_Priority_Attribute_Test
87    [Template]  Temporarily Set PNOR Attribute
88
89    # Property        Value
90    Priority          ${0}
91    Priority          ${1}
92    Priority          ${127}
93    Priority          ${255}
94
95
96Host Set Priority To Invalid Values
97    [Documentation]  Attempt to set the priority of an image to an invalid
98    ...              value and expect an error.
99    [Tags]  Host_Set_Priority_To_Invalid_Values
100    [Template]  Set Priority To Invalid Value And Expect Error
101
102    # Version Type              Priority
103    ${VERSION_PURPOSE_HOST}    ${-1}
104    ${VERSION_PURPOSE_HOST}    ${256}
105
106
107Set RequestedActivation To None
108    [Documentation]  Set the RequestedActivation of the image to None and
109    ...              verify that it is in fact set to None.
110    [Tags]  Set_RequestedActivation_To_None
111
112    ${software_objects}=  Get Software Objects
113    Set Host Software Property  @{software_objects}[0]  RequestedActivation
114    ...  ${REQUESTED_NONE}
115    ${software_properties}=  Get Host Software Property  @{software_objects}[0]
116    Should Be Equal As Strings  &{software_properties}[RequestedActivation]
117    ...  ${REQUESTED_NONE}
118
119
120Set RequestedActivation And Activation To Invalid Value
121    [Documentation]  Set the RequestedActivation and Activation propreties of
122    ...              the image to an invalid value and verify that it was not
123    ...              changed.
124    [Template]  Set Property To Invalid Value And Verify No Change
125    [Tags]  Set_RequestedActivation_And_Activation_To_Invalid_Value
126
127    # Property              Version Type
128    RequestedActivation     ${VERSION_PURPOSE_HOST}
129    Activation              ${VERSION_PURPOSE_HOST}
130
131
132Upload And Activate Multiple Host Images
133    [Documentation]  Upload another PNOR image and verify that its state is
134    ...              different from all others.
135    [Tags]  Upload_And_Activate_Multiple_Host_Images
136    [Template]  Activate Image And Verify No Duplicate Priorities
137    [Setup]  Upload And Activate Multiple BMC Images Setup
138
139    # Image File Path              Image Purpose
140    ${ALTERNATE_IMAGE_FILE_PATH}   ${VERSION_PURPOSE_HOST}
141
142
143Set Same Priority For Multiple Host Images
144    [Documentation]  Attempt to set the priority to be the same for two PNOR
145    ...              images and verify that the priorities are not the same.
146    [Tags]  Set_Same_Priority_For_Multiple_Host_Images
147
148    Run Keyword If  '${PREV_TEST_STATUS}' == 'FAIL'
149    ...  Fail  Activation of alternate image failed. Cannot set priority.
150    Set Same Priority For Multiple Images  ${VERSION_PURPOSE_HOST}
151
152
153Delete Host Image
154    [Documentation]  Delete a PNOR image from the BMC and PNOR flash chip.
155    [Tags]  Delete_Host_Image
156    [Setup]  Initiate Host PowerOff
157
158    ${software_objects}=  Get Software Objects
159    ...  version_type=${VERSION_PURPOSE_HOST}
160    ${num_images}=  Get Length  ${software_objects}
161    Should Be True  0 < ${num_images}
162    ...  msg=There are no PNOR images on the BMC to delete.
163    Delete Image And Verify  @{software_objects}[0]  ${VERSION_PURPOSE_HOST}
164
165
166*** Keywords ***
167
168Temporarily Set PNOR Attribute
169    [Documentation]  Update the PNOR attribute value.
170    [Arguments]  ${attribute_name}  ${attribute_value}
171
172    # Description of argument(s):
173    # attribute_name    Host software attribute name (e.g. "Priority").
174    # attribute_value   Value to be written.
175
176    ${image_ids}=  Get Software Objects
177    ${init_host_properties}=  Get Host Software Property  ${image_ids[0]}
178    ${initial_priority}=  Set Variable  ${init_host_properties["Priority"]}
179
180    Set Host Software Property  ${image_ids[0]}  ${attribute_name}
181    ...  ${attribute_value}
182
183    ${cur_host_properties}=  Get Host Software Property  ${image_ids[0]}
184    Should Be Equal As Integers  ${cur_host_properties["Priority"]}
185    ...  ${attribute_value}
186
187    # Revert to to initial value.
188    Set Host Software Property
189    ...  ${image_ids[0]}  ${attribute_name}  ${initial_priority}
190
191
192Code Update Setup
193    [Documentation]  Do code update test case setup.
194    # - Clean up all existing BMC dumps.
195    # - Clean up all currently install PNOR images.
196
197    Run Keyword And Ignore Error  Smart Power Off
198    Delete All Dumps
199    Delete Error Logs
200    Run Keyword If  'true' == '${DELETE_OLD_PNOR_IMAGES}'
201    ...  Delete All PNOR Images
202    Run Keyword If  'true' == '${DELETE_OLD_GUARD_FILE}'  BMC Execute Command
203    ...  rm -f /var/lib/phosphor-software-manager/pnor/prsv/GUARD
204
205
206Upload And Activate Multiple BMC Images Setup
207    [Documentation]  Check that the ALTERNATE_FILE_PATH variable is set.
208
209    Should Not Be Empty  ${ALTERNATE_IMAGE_FILE_PATH}
210    Delete All PNOR Images
211    Upload And Activate Image  ${IMAGE_FILE_PATH}
212
213Get PNOR Extended Version
214    [Documentation]  Return the PNOR extended version.
215    [Arguments]  ${manifest_path}
216
217    # Description of argument(s):
218    # manifest_path  Path of the MANIFEST file
219    #                (e.g. "/tmp/images/abc123/MANIFEST").
220
221    ${version}= BMC Execute Command
222    ...  grep extended_version= ${manifest_path}
223    [return] ${version.split(",")}
224
225
226Code Update Test Teardown
227    [Documentation]  Do code update test case teardown.
228    # 1. Collect FFDC if test case failed.
229    # 2. Collect FFDC if test PASS but error log exists.
230
231    FFDC On Test Case Fail
232    Run Keyword If  '${TEST_STATUS}' == 'PASS'  Check Error And Collect FFDC
233