1*** Settings *** 2Documentation Update the BMC code on a target BMC. 3... Execution Method: 4... python -m robot -v OPENBMC_HOST:<hostname> 5... -v IMAGE_FILE_PATH:<path/*.tar> bmc_code_update.robot 6 7Library ../../lib/code_update_utils.py 8Library ../../lib/gen_robot_keyword.py 9Variables ../../data/variables.py 10Resource ../../lib/utils.robot 11Resource ../../lib/boot_utils.robot 12Resource code_update_utils.robot 13Resource ../../lib/code_update_utils.robot 14Resource ../../lib/openbmc_ffdc.robot 15Resource ../../lib/dump_utils.robot 16Resource ../../lib/certificate_utils.robot 17 18Suite Setup Suite Setup Execution 19 20Test Teardown Test Teardown Execution 21 22Force Tags BMC_Code_Update 23 24*** Variables *** 25 26${QUIET} ${1} 27${IMAGE_FILE_PATH} ${EMPTY} 28${ALTERNATE_IMAGE_FILE_PATH} ${EMPTY} 29${SKIP_UPDATE_IF_ACTIVE} false 30${dump_id} ${EMPTY} 31${running_persistence_test} ${FALSE} 32${test_errlog_text} AutoTestSimple 33 34*** Test Cases *** 35 36Test Basic BMC Performance Before BMC Code Update 37 [Documentation] Check performance of memory, CPU & file system of BMC. 38 [Tags] Test_Basic_BMC_Performance_Before_BMC_Code_Update 39 40 Open Connection And Log In 41 Check BMC Performance 42 43Prepare Persistent Data 44 [Documentation] Set data that should persist across the code update. 45 [Tags] Prepare_Persistent_Data 46 47 # Install the debug tarball. 48 BMC Execute Command rm -rf /tmp/tarball 49 Install Debug Tarball On BMC tarball_file_path=${DEBUG_TARBALL_PATH} 50 51 # Create a dummy error log and dump. 52 BMC Execute Command /tmp/tarball/bin/logging-test -c ${test_errlog_text} 53 ${dump_id}= Create User Initiated Dump 54 Check Dump Existence ${dump_id} 55 Set Suite Variable ${dump_id} 56 57 # Set persistent settings. 58 ${autoreboot_dict}= Create Dictionary data=${0} 59 Write Attribute ${CONTROL_HOST_URI}auto_reboot AutoReboot 60 ... data=${autoreboot_dict} 61 ${onetime_dict}= Create Dictionary data=${0} 62 Write Attribute ${CONTROL_HOST_URI}boot/one_time Enabled 63 ... data=${onetime_dict} 64 65 # Let the remaining test cases know we are doing a persistence test so we 66 # do not delete logs. 67 Set Suite Variable ${running_persistence_test} ${TRUE} 68 69 70REST BMC Code Update 71 [Documentation] Do a BMC code update by uploading image on BMC via REST. 72 [Tags] REST_BMC_Code_Update 73 [Teardown] REST BMC Code Update Teardown 74 75 Run Keyword And Ignore Error List Installed Images BMC 76 77 Upload And Activate Image ${IMAGE_FILE_PATH} 78 ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} 79 OBMC Reboot (off) 80 Verify Running BMC Image ${IMAGE_FILE_PATH} 81 82 83Verify Error Log Persistency 84 [Documentation] Check that the error log is still present after a 85 ... code update. 86 [Tags] Verify_Error_Log_Persistency 87 88 ${error_log_paths}= Read Properties ${BMC_LOGGING_ENTRY}list 89 Log To Console ${error_log_paths} 90 ${test_error_message}= Read Attribute @{error_log_paths}[-1] Message 91 Should Be Equal ${test_error_message} 92 ... example.xyz.openbmc_project.Example.Elog.${test_errlog_text} 93 Delete Error Log Entry @{error_log_paths}[-1] 94 95 96Verify BMC Dump Persistency 97 [Documentation] Check that the BMC dump present after a code update. 98 [Tags] Verify_BMC_Dump_Persistency 99 [Teardown] Set Suite Variable ${running_persistence_test} ${FALSE} 100 101 Check Dump Existence ${dump_id} 102 Delete BMC Dump ${dump_id} 103 104 105Verify Settings Persistency 106 [Documentation] Verify that the settings from 'Prepare Persistent Data' 107 ... are still set correctly after the code update. 108 [Tags] Verify_Settings_Persistency 109 110 ${autoreboot_enabled}= Read Attribute ${CONTROL_HOST_URI}auto_reboot 111 ... AutoReboot 112 Should Be Equal ${autoreboot_enabled} ${0} 113 ${onetime_enabled}= Read Attribute ${CONTROL_HOST_URI}boot/one_time 114 ... Enabled 115 Should Be Equal ${onetime_enabled} ${0} 116 117 # Set values back to their defaults 118 ${autoreboot_dict}= Create Dictionary data=${1} 119 Write Attribute ${CONTROL_HOST_URI}auto_reboot AutoReboot 120 ... data=${autoreboot_dict} 121 ${onetime_dict}= Create Dictionary data=${1} 122 Write Attribute ${CONTROL_HOST_URI}boot/one_time Enabled 123 ... data=${onetime_dict} 124 125 126Upload And Activate Multiple BMC Images 127 [Documentation] Upload another BMC image and verify that its state is 128 ... different from all others. 129 [Tags] Upload_And_Activate_Multiple_BMC_Images 130 [Template] Activate Image And Verify No Duplicate Priorities 131 [Setup] Upload And Activate Multiple BMC Images Setup 132 133 # Image File Path Image Purpose 134 ${ALTERNATE_IMAGE_FILE_PATH} ${VERSION_PURPOSE_BMC} 135 136 137BMC Set Priority To Invalid Values 138 [Documentation] Attempt to set the priority of an image to an invalid 139 ... value and expect an error. 140 [Tags] BMC_Set_Priority_To_Invalid_Values 141 [Template] Set Priority To Invalid Value And Expect Error 142 143 # Version Type Priority 144 ${VERSION_PURPOSE_BMC} ${-1} 145 ${VERSION_PURPOSE_BMC} ${256} 146 147 148Delete BMC Image 149 [Documentation] Delete a BMC image from the BMC flash chip. 150 [Tags] Delete_BMC_Image 151 152 ${software_object}= Get Non Running BMC Software Object 153 Delete Image And Verify ${software_object} ${VERSION_PURPOSE_BMC} 154 155 156BMC Image Priority Attribute Test 157 [Documentation] Set "Priority" attribute. 158 [Tags] BMC_Image_Priority_Attribute_Test 159 [Template] Temporarily Set BMC Attribute 160 161 # Property Value 162 Priority ${0} 163 Priority ${1} 164 Priority ${127} 165 Priority ${255} 166 167 168Delete All Non Running BMC Images 169 [Documentation] Delete all non running BMC images. 170 [Tags] Delete_All_Non_Running_BMC_Images 171 172 ${version_id}= Upload And Activate Image ${ALTERNATE_IMAGE_FILE_PATH} 173 ... skip_if_active=true 174 Delete All Non Running BMC Images 175 176 ${software_ids}= Get Software Objects Id 177 ... version_type=${VERSION_PURPOSE_BMC} 178 Should Not Contain ${software_ids} ${version_id} 179 180 181Test Certificate Persistency After BMC Code Update 182 [Documentation] Test certificate persistency after BMC update. 183 [Tags] Test_Certificate_Persistency_After_BMC_Code_Update 184 185 # Create certificate sub-directory in current working directory. 186 Create Directory certificate_dir 187 OperatingSystem.Directory Should Exist ${EXECDIR}${/}certificate_dir 188 189 ${cert_file_path}= Generate Certificate File Via Openssl 190 ... Valid Certificate Valid Privatekey 191 ${file_data}= OperatingSystem.Get Binary File ${cert_file_path} 192 ${cert_file_content}= OperatingSystem.Get File ${cert_file_path} 193 194 Install Certificate File On BMC ${CLIENT_CERTIFICATE_URI} 195 ... data=${file_data} 196 197 ${bmc_cert_content}= Get Certificate File Content From BMC Client 198 Should Contain ${cert_file_content} ${bmc_cert_content} 199 200 Upload And Activate Image ${IMAGE_FILE_PATH} 201 ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} 202 OBMC Reboot (off) 203 Verify Running BMC Image ${IMAGE_FILE_PATH} 204 205 ${bmc_cert_content}= Get Certificate File Content From BMC Client 206 Should Contain ${cert_file_content} ${bmc_cert_content} 207 208 209Test Basic BMC Performance After Code Update 210 [Documentation] Check performance of memory, CPU & file system of BMC. 211 [Tags] Test_Basic_BMC_Performance_After_Code_Update 212 213 Open Connection And Log In 214 Check BMC Performance 215 216 217*** Keywords *** 218 219Temporarily Set BMC Attribute 220 [Documentation] Update the BMC attribute value. 221 [Arguments] ${attribute_name} ${attribute_value} 222 223 # Description of argument(s): 224 # attribute_name BMC software attribute name (e.g. "Priority"). 225 # attribute_value Value to be written. 226 227 ${image_ids}= Get Software Objects ${VERSION_PURPOSE_BMC} 228 ${init_bmc_properties}= Get Host Software Property ${image_ids[0]} 229 ${initial_priority}= Set Variable ${init_bmc_properties["Priority"]} 230 231 Set Host Software Property ${image_ids[0]} ${attribute_name} 232 ... ${attribute_value} 233 234 ${cur_bmc_properties}= Get Host Software Property ${image_ids[0]} 235 Should Be Equal As Integers ${cur_bmc_properties["Priority"]} 236 ... ${attribute_value} 237 238 # Revert to to initial value. 239 Set Host Software Property 240 ... ${image_ids[0]} ${attribute_name} ${initial_priority} 241 242 243Upload And Activate Multiple BMC Images Setup 244 [Documentation] Check that the ALTERNATE_FILE_PATH variable is set. 245 246 Should Not Be Empty ${ALTERNATE_IMAGE_FILE_PATH} 247 248 249REST BMC Code Update Teardown 250 [Documentation] Do code update test teardown. 251 252 FFDC On Test Case Fail 253 Run Keyword If Test Failed Fatal Error msg=Code update failed. 254 255 256Suite Setup Execution 257 [Documentation] Do code update test case setup. 258 # - Clean up all existing BMC dumps. 259 260 Run Key Delete All Dumps ignore=1 261 Run Keyword And Ignore Error Smart Power Off 262 263Test Teardown Execution 264 [Documentation] Do code update test case teardown. 265 # 1. Collect FFDC if test case failed. 266 # 2. Collect FFDC if test PASS but error log exists. 267 268 # Don't delete our logs if we want to persist them for tests. 269 Return From Keyword If ${running_persistence_test} 270 271 FFDC On Test Case Fail 272 Run Keyword If '${TEST_STATUS}' == 'PASS' Check Error And Collect FFDC 273 Close All Connections 274